0% found this document useful (0 votes)
7 views3 pages

Control Supply To Match AGiven Results

This document provides instructions on installing and using the ControlSupplyToMatchAGivenResults macro, which controls supply values to achieve a specified temperature profile. It outlines the inputs required for the macro and the outputs generated, including a solved project and a text file detailing iterations. The installation path for the macro and steps to call and run it within the Flux software are also included.

Uploaded by

Cầu Cao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views3 pages

Control Supply To Match AGiven Results

This document provides instructions on installing and using the ControlSupplyToMatchAGivenResults macro, which controls supply values to achieve a specified temperature profile. It outlines the inputs required for the macro and the outputs generated, including a solved project and a text file detailing iterations. The installation path for the macro and steps to call and run it within the Flux software are also included.

Uploaded by

Cầu Cao
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Macros

How to use macro : ControlSupplyToMatchAGivenResults?

Last update 08/04/2014


Version soft Flux V11.2.1
Author CF
Reviewers

Introduction This document deals with how to install a macro, and how to use the
ControlSupplyToMatchAGivenResults macro. It will include the following topics:
• Macro definition: ControlSupplyToMatchAGivenResults
• Install a macro

Macro definition: ControlSupplyToMatchAGivenResults

Goal of the The goal of this macro is to control step by step the value of the supply (RMS value of
macro voltage or current source) to have a output matching a given results. This macro allows
predicting the supply in order to obtain a given profile of temperature. The inputs of the
macro ControlSupplyToMatchAGivenResults.PFM are:
- The parameter to pilot
- The variation parameter defining the output (I/O Parameter or sensor)
- A tabulated parameter describing the desired profile of temperature
- The value of the time step
- The end time of the scenario
- The precision to reach on the temperature
- The name of the scenario to create
- The maximum number of iterations to find the value of the supply for each time step

Before running the macro, the user has to define the profile of expected temperature. It
should be done thanks to a tabulated I/O parameter.

As output, the macro will create:


The project solved with a supply controlled to obtain predefined results.
A text file created in the working directory containing for each time step the iteration done to
find value of supply given predefined results.

1
Macros

Install a macro

Path Macros delivered with Flux are directly installed in folder :


Installation C:\Program Files\Altair\2020\flux\Extensions\Macros

(If Flux is installed at the path proposed by default C:\Program Files\Altair)

Calling a macro In order to use a macro, you have to follow the next steps:
Step Actions
1 Open Flux
2 Click on [Project] [Macro] [Load], and select the right macro

3 To run a macro, you have to click on [Project] [Macro] [Run]

Then select the macro you want to run.

2
Macros

Macro description

Folder Macros Description


ControlSupplyToMatchAGiven Control supply to match a given results
Results.pfm Input:
• The parameter to pilot
• The variation parameter defining the output (I/O
Parameter or sensor)
• A tabulated parameter describing the desired profile of
temperature
• The value of the time step
• The end time of the scenario
• The precision to reach on the temperature
• The name of the scenario to create
• The maximum number of iterations to find the value of
the supply for each time step

Output:
• Solved project
• Text file containing iteration done

répertoire Macros Description


ControlSupplyToMatchAGiven Contrôle de la source pour obtenir un certain profil de résultat
Results.pfm Entrée:
• Le paramètre E/S à piloter
• Le paramètre E/S ou capteur définissant le résultat voulu
• -Un paramètre tabulé définissant le profil de température
à obtenir
• La valeur du pas de temps
• Le temps final de la simulation (du scenario de
résolution)
• La précision désirée sur la température
• Le nom du scenario de résolution à créer
• -Le nombre max d’itérations pour trouver la valeur de la
source à chaque pas de temps

Sortie:
• Projet résolu
• Fichier texte détaillant les itérations réalisées