CV9003A
CV9003A
Model : CV9003A - _ _ - _ _ - _ _ - _
Revision 04
Engineering Brian Leung
Date 13 October 2003
Our Reference 9003
ADDRESS : 1st FLOOR, EFFICIENCY HOUSE, 35 TAI YAU STREET, SAN PO KONG,
KOWLOON, HONG KONG.
TEL : (852) 2341 3238 (SALES OFFICE) (852) 2342 8228 (GENERAL OFFICE)
FAX : (852) 2357 4237 (SALES OFFICE)
E-MAIL : [email protected]
URL : http://www.cloverdisplay.com
CLOVER DISPLAY LTD. CV9003A
MODE OF DISPLAY
Display mode Display condition Viewing direction
□ TN positive □ Reflective type □ 6 O’ clock
□ TN negative □ Transflective type □ 12 O’ clock
□ Transmissive type □ 3 O’ clock
□ Others □ 9 O’ clock
SPEC.REV.04 PAGE 1 OF 9
CLOVER DISPLAY LTD. CV9003A
GENERAL DESCRIPTION
Display mode : 10 Digits + Icons, COG LCD module
Driving method : 1/4 Duty, 1/3Bias
Interface : I2C serial
Controller IC : Philips PCF8576 or equivalent
For the detailed information, please refer to IC specifications.
SPEC.REV.04 PAGE 2 OF 9
CLOVER DISPLAY LTD. CV9003A
MECHANICAL DIMENSIONS
Item Dimension Unit
Outline Dimension 42.0(L)x19.5(W)x2.8 Max.(H) mm
Viewing Area 39.0(L)x9.2(W) mm
SPEC.REV.04 PAGE 3 OF 9
CLOVER DISPLAY LTD. CV9003A
INSTRUCTION
command/opcode options description
MODE SET LCD drive mode bits M1 M0 Defines LCD drive mode
static(1 BP) 0 1
C 10 LP E B M1 MO 1:2 MUX(2BP) 1 0
1:3 MUX(3BP) 1 1
1:4 MUX(4BP) 0 0
SPEC.REV.04 PAGE 4 OF 9
CLOVER DISPLAY LTD. CV9003A
TIMING CHARACTERISTICS OF COMPATIBLE CONTROLLER CHIPS
Parameters Symbol Recommended timing Parameters Symbol Recommended timing
Bus free time tBUF(min) 105s Data hold time tHD(min) 365s
Start condition tHD(min) 365s Data Set-up Time tSU (min) 250ns
hold time
SCL LOW time tLOW(min) 105s Rise time tR(max) 1s
SCL HIGH time tHIGH (min) 365S Fall Time tF(max) 300ns
Start condition tSU(min) 105s Stop condition tSU(min) 105s
set-up time tSU(max) 155s set-up time tS(max) 155s
SPEC.REV.04 PAGE 5 OF 9
CLOVER DISPLAY LTD. CV9003A
ELECTRO-OPTICAL CHARACTERISTICS
MEASURING CONDITION: POWER SUPPLY = VOP / 64 Hz
TEMPERATURE = 22 5 C
RELATIVE HUMIDITY = 60 15 %
ITEM SYMBOL UNIT TYP. TN
RESPONSE TIME Ton ms 85
Toff ms 115
CONTRAST RATIO Cr - 12
V3:00 70
VIEWING ANGLE V6:00 55
(6 O’clock) V9:00 70
Cr 2 V12:00 15
THE ELECTRO-OPTICAL CHARACTERISTICS ARE MEASURED VALUE BUT NOT GUARANTEED ONES.
SAMPLING METHOD
SAMPLING PLAN: MIL-STD 105E
CLASS OF AQL: LEVEL II/ SINGLE SAMPLING
MAJOR-0.65% MINOR – 1.5%
SPEC.REV.04 PAGE 6 OF 9
CLOVER DISPLAY LTD. CV9003A
QUALITY STANDARD
SPEC.REV.04 PAGE 7 OF 9
CLOVER DISPLAY LTD. CV9003A
SPEC.REV.04 PAGE 8 OF 9
CLOVER DISPLAY LTD. CV9003A
HANDLING PRECAUTIONS
Do not wipe the display surface with dry or hard materials that will damage the polarizer surface. Do not
use the following solvent;
-water, ketone, aromatics
Remove the protective film slowly and, if possible, under ESD control device like ion blower and
humidity of working room should be kept over 50%RH to reduce risk of static charge.
(3) PACKAGING
Avoid intense shock and falls from a height and do not operate or store them exposed direct to sunshine
or high temperature/humidity.
Response time will be extremely delayed at low temperature, and LCD’s show dark color at high
temperature. However those phenomena do not mean malfunction or out of order with LCD’s.
Some font will be abnormally displayed when the display area is pushed hard during operation. But it
resumes normal condition after turning off once.
(6) SAFETY
For crash damaged or unnecessary LCD’s, it is recommended to wash off liquid crystal by either of
solvents such as acetone and ethanol and should be burned up later.
When any liquid leaked out of a damaged glass cell comes in contact with your hands, wash it off with
soap and water.
WARRANTY
CLOVER will replace or repair any of her LCD module in accordance with her LCD specification for a
period of one year from date of shipment. The warranty liability of Clover is limited to repair and/or
replacement. Clover will not be responsible for any subsequent or consequential event.
SPEC.REV.04 PAGE 9 OF 9