LATIVET
LATIVET
Features
High DQE Flat Panel Detector
Specifications
The TFT detector delivers the high Detective Quantum Efficiency (DQE) Digital Image Receptor
allowing you to take full advantage of available signal while reducing dose. Usage Digital X-ray system or Upgrading to DR
Sensor TFT array Flat Panel Detector
Cost effective Solution
A/D 14 bits
Minimize your investment and maximize your efficiency cost-effectively.
Extend the life of your conventional X-Ray equipment with LATIVET. Preview image access time* Approx. 1.7 seconds
Realize all the cost savings of this complete DR system. DICOM 3.0, Windows Printer support,
DICOM
DICOM Printer Support, and others
Quick and Fastest workflow and productivity
Voltage 100~240V, 50 / 60Hz
After few seconds, an image is immediately available at the LATIVET’s
capture console(Zview), and can be quickly forwarded to multiple Environment -20°C ~ 70°C, 15% ~ 90% RH (non-condensing)
network destinations. Zview Consol Veterinary image processing Engine Console
Actual times may differ due to various factors.
High speed Network integration
DICOM 3.0 compatibility enables seamless data transfer to any DICOM X-ray Table
hard copy output device or PACS for efficient printing, archiving, and SID Fixed 1,050mm
remoteviewing of images. Table top size 1200 726
Demension 1200(W) 998(D) 1988(H)
Zview Console (DR Operating Console)
Thumb
ThumbnailnailView,
View,patient
patientInfo
Infoand
andetc
etc Lateral 150mm
4-way Table top travel
Main
MainScreen
ScreenConsole
Console Longitudinal 100mm
Patient
Patientinformation
informationGUI
GUI
Automatic
AutomaticPrePre&&Post
Postimage
imageenhancement
enhancement X-ray Generator (High Frequency Generator)
Expands
Expandsimage
imageprocessing
processingfor foroptimized
optimizedviewing
viewing kV range 40 to 150kV / 125kV
Enhances
Enhancesvariable
variabledensity
densityandandform
formshading
shading mA range 10 to 500 mA
DICOM
DICOMsending
sendingand
andPrinting,
Printing,Windows
WindowsPrinting
Printing
mAs range 0.1 to 630 mAs
Easy
EasyCalibration
Calibration&&User
Usersetting
setting
CD
CD//DVD
DVDArchiving
Archiving Time range 0.1 ms to 1000 ms (10 sec.)
Language
Languagesupport
support Line Power (VAC) 220 / 240 / Single Phase
X-ray Tube E7239X / Toshiba (125kV)
PACS (Optional)
Viewer
ViewerSolution
Solution
Intelligently
Intelligentlyplaced
placedthumbnails
thumbnailsfor
formaximum
maximumnavigation
navigationcomfort
comfort User Options
Icon
Icondriven
drivenwindow/level
window/levelcontrol,
control,magnification,
magnification,measure
measureand
andother
other
DICOM
DICOMPrintPrint Options
Real
RealPACS
PACSDICOM
DICOMprint
printoutputs
outputsimage
imagedata
dataininthe
thesystem
systemtotoX-Ray
X-Rayfilm
film Capacitor Bank 40kW Use for nominal power outlet
DICOM
DICOMCD-View
CD-View PACS Full package PACS
Supports
SupportsDICOMDIR
DICOMDIRstandard
standard Medical Monitor 5M, 3M B / W LCD Monitor
Image
Imageprocessing
processingfunctions
functions