Site Preparation Guide: NCR Selfserv™ Xk22 (2246) Kiosk

The NCR SelfServ™ XK22 (2246) Kiosk Site Preparation Guide provides essential information for preparing a site for the installation of the kiosk, including safety requirements, customer responsibilities, and environmental conditions. It emphasizes the importance of proper site preparation to avoid issues post-installation and outlines warranty terms and procedures for handling out-of-box failures. The document also details specifications for electrical and peripheral requirements, ensuring compliance with relevant safety standards.

Uploaded by

Gilvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views52 pages

Site Preparation Guide: NCR Selfserv™ Xk22 (2246) Kiosk

The NCR SelfServ™ XK22 (2246) Kiosk Site Preparation Guide provides essential information for preparing a site for the installation of the kiosk, including safety requirements, customer responsibilities, and environmental conditions. It emphasizes the importance of proper site preparation to avoid issues post-installation and outlines warranty terms and procedures for handling out-of-box failures. The document also details specifications for electrical and peripheral requirements, ensuring compliance with relevant safety standards.

Uploaded by

Gilvan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 52

Site Preparation Guide

NCR SelfServ™ XK22 (2246) Kiosk

BCC5-0000-5390
Issue E
The product described in this document is a licensed product of NCR Corporation.

NCR is a registered trademark of NCR Corporation. NCR SelfServ is a trademark of NCR Corporation in the United States and/or other
countries. Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies
and are hereby acknowledged.

The terms HDMI and HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI
Licensing LLC in the United States and other countries.

Where creation of derivative works, modifications or copies of this NCR copyrighted documentation is permitted under the terms and
conditions of an agreement you have with NCR, NCR's copyright notice must be included.

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available.
NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances,
photographs are of equipment prototypes. Software screen images are representative, and in some cases, may not match a customer’s
installed software exactly. Therefore, before using this document, consult with your NCR representative or NCR office for information that
is applicable and current.

To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book. Please
use the link below to send your comments.

Email: [email protected]

Copyright © 2024
By NCR Corporation
Global Headquarters
864 Spring St NW
Atlanta, GA 30308
U.S.A.
All Rights Reserved
i

Preface
Audience
This book is written for hardware installer/service personnel, system integrators, and field
engineers.

Notice: This document is NCR proprietary information and is not to be disclosed or


reproduced without consent.

Safety Requirements
The NCR SelfServ™ XK22 (2246) Kiosk conforms to all applicable legal requirements. To view
the compliance statements see the NCR Selfserv Kiosks Safety and Regulatory Information
(B005-0000-2063).

Caution: The on/off switch is a logic switch only. The AC line voltage primaries are live at all
times when the power cord is connected. Therefore, disconnect the AC power cord before
opening the unit to install features or service this terminal.

Lithium Battery Warning


Warning: Danger of explosion if battery is incorrectly replaced. Replace only with the
same or equivalent type as recommended by the manufacturer. Discard used
batteries according to the manufacturer's instructions.

Attention: Il y a danger d'explosion s'il y a remplacement incorrect de la batterie.


Remplacer uniquement avec une batterie du même type ou d'un type recommandé
par le constructeur. Mettre au rébut les batteries usagées conformément aux
instructions du fabricant.

Battery Disposal (Switzerland)


Refer to Annex 4.10 of SR814.013 for battery disposal.

IT Power System
This product is suitable for connection to an IT power system with a phase-to-phase voltage not
exceeding 240 V.
ii

Peripheral Usage
This terminal should only be used with peripheral devices that are certified by the appropriate
safety agency for the country of installation (UL, CSA, TUV, VDE) or those which are
recommended by NCR Corporation.

Warning: DO NOT connect or disconnect the transaction printer while the terminal is
connected to AC power. This can result in system or printer damage.

Warning: DO NOT connect or disconnect any serial peripherals while the terminal is
connected to AC power. This can result in system or printer damage.

Grounding Instructions
In the event of a malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This product is equipped with an electric
cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and grounded in accordance with all
local codes and ordinances. Do not modify the plug provided – if it will not fit the outlet, have
the proper outlet installed by a qualified electrician. Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.

The conductor with insulation having an outer surface that is green with or without yellow
stripes is the equipment-grounding conductor.

If repair or replacement of the electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal. Check with a qualified electrician or service
personnel if the grounding instructions are not completely understood, or if you are in doubt
as to whether the product is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that
accept the product’s plug. Repair or replace damaged or worn cords immediately.

Perchlorate Material Notification


Note: This is applicable to the State of California only. Special handling may apply.

This Product may contain a lithium coin cell battery(s) which contains Perchlorate and are
subject to the State of California’s Best Management Practices (BMP) Regulations for
Perchlorate Materials.

Please visit this website for more information: www.dtsc.ca.gov/hazardouswaste/perchlorate


iii

Warranty
Warranty terms vary by region and country.

All parts of this product that are subject to normal wear and tear are not included in the
warranty. In general, damages due to the following are not covered by the warranty.

• Improper or insufficient maintenance

• Improper use or unauthorized modifications of the product.

• Inadequate location or surroundings. Site installation must conform to guidelines listed in


the NCR SelfServ™ XK22 (2246) Site Preparation Guide (BCC5-0000-5390) and the NCR
Workstation and Peripheral AC Wiring Guide (BST0-2115-53).

If you need NCR Warranty support for post installation issues, please contact NCR Customer
Services at the following numbers:

• 1-800-262-7782 (U.S. or Canada)

• 1-937-445-1936 (International)
iv

Out of Box Failure (OBF) for Hospitality Products


If you experience an out of box failure (OBF) during installation or staging related to a missing,
wrong, or defective unit or item, contact NCR through any of the following options, which may
differ based on the customer sales channel:

• Local Office: Field Services will need to log a new case in GEMS.

• Direct (L1 Support): If the customer is contracted for level 1 support, call +1-800-792-
5642, Option 1, Option 1, then open a new case. The “direct support team” would then
need to escalate the GEMS incident to the appropriate support team. Standard would go to
HWT, Brand would be assigned to Brand.

• Direct Customer with Corporate Help Desk: Log a new case on NAYS

• Resellers: Reseller will log a new case on NAYS

For assistance with the OBF process, provide the following details:

• NCR Sales Order Number (Sales Order Number is located on the box)

• Date of product installation or staging when failure is detected

• Product Model Number

• Unit Serial Number

• NCR Part Number or Model Number of defective, missing, or wrong components

• Description of failure (please be specific. For example: “display will not power on”)

• Customer/Requestor’s contact name, phone number and/or e-mail address

• Address to ship replacement part(s)

Hardware that fails after installation or staging DOES NOT qualify as an Out of Box
failure but would be managed using same process described above.
v

Table of Contents

NCR SelfServ™ XK22 (2246) Site Preparation Guide


Overview 1
Product IDs (PIDs) 2
Customer Responsibilities 3
Third Party Peripheral Certification 4
Environmental Requirements 5
Barometric Pressure 5
Temperature 5
Humidity 5
Electrical Requirements 6
Power Requirements 6
AC Wiring Requirements 6
LAN Communications 7
Transient Protection 8
AC Power Line Transient Protection 8
Data Line Transient Protection 9
Weight 10
Unit Weight 10
Shipping Weight 10
Kiosk Dimensions 11
Countertop Mount with Small PIN Pad 11
Countertop Mount with Large PIN Pad 12
Wall Mount with Small PIN Pad 13
Wall Mount with Large PIN Pad 14
Pedestal Mount, Bolted with Small PIN Pad 15
Pedestal Mount, Bolted with Large PIN Pad 16
Pedestal Mount, Free Standing with Small PIN Pad 17
Pedestal Mount, Free Standing with Large PIN Pad 18
vi

Dual Pedestal Mount, Bolted with Small PIN Pad 19


Accessibility of Devices 20
Heights and Depths (Countertop and Wall Mount Configurations) 21
Height from Ground (Countertop and Wall Mount Con-
figurations) 22
Depth from Front of Door (Countertop and Wall Mount Con-
figurations) 23
Heights and Depths (Pedestal Mount Configuration) 24
Height from Ground (Pedestal Mount Configuration) 25
Depth from Front of Base (Pedestal Mount Configuration) 26
Distance for Voice Guidance 27
Interface Devices 29
Service Clearance 30
Kiosk with Small PIN Pad 30
Kiosk with Large PIN Pad 30
Countertop Mounting Details 31
Recommended Bolt Specifications 32
Mounting Dimensions 33
Cable Routing Options 34
Wall Mounting Details 35
Recommended Bolt Specifications 36
Concrete Wall Installation 36
Dry Wall Installation 36
Mounting Dimensions 37
Cable Routing Options 39
Pedestal Mounting Details 40
Recommended Bolt Specifications 41
Mounting Dimensions 42
Cable Routing Options 43
vii

Revision Record

Issue Date Remarks

A Dec 2019 First Issue

B Mar 2020 • Added perchlorate material notification


• Updated the Out of Box Failure (OBF) sections for Retail and
for Hospitality
• Updated cleaning procedures

C May 2020 Added dimensions for Dual Pedestal Mount

D Feb 2021 • Updated Kiosk Dimensions sections. Showed dimensions


for one Small PIN Pad and one Large PIN Pad only (MX925
as the largest)
• Added Accessibility information for Ingenico Lane 3000,
Ingenico Lane 5000, and Verifone P400 PIN Pads

C Nov 2024 • Removed OBF section


• Updated links
• Rebranded to Voyix template
NCR SelfServ™ XK22 (2246) Site Preparation
Guide

Overview

This document provides the information necessary to prepare a site to NCR specifications
before installing an NCR SelfServ™ XK22 (2246) Kiosk. The site must be properly prepared
before the kiosk is installed because site preparation deficiencies may be difficult to detect
and correct after installation.
2 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Product IDs (PIDs)


The NCR SelfServ™ XK22 (2246) Kiosk is available in the following models, which can be
configured with various features.

Name Description

2246-1000-8090 XK22 Kiosk (Retail) w/ uNav

2246-1100-8090 XK22 Kiosk (Retail) w/o uNav

2246-5010-1001 XK22 Kiosk HOSP; Single-sided; i3; 8GB; 120GB SSD; Printer; Imager;
VX820; HOSP Win 10 OS

2246-5010-1004 XK22 Kiosk HOSP; Single-sided; i3; 8GB; 120GB SSD; Printer; Imager;
MSR; HOSP Win 10 OS

2246-5010-1005 XK22 Kiosk HOSP; Equinox 6200M Mount, i3; 8GB; 120GB SSD;
Printer; Imager; HOSP Win 10 OS, US Power Cord

2246-5010-1201 XK22 Kiosk HOSP; VX820 / IPP350 mount, i3; 8GB; 120GB SSD;
Printer; Imager; HOSP Win 10 OS, UK Power Cord

2246-5010-1205 XK22 Kiosk HOSP; Equinox 6200M mount, i3; 8GB; 120GB SSD;
Printer; Imager; HOSP Win 10 OS, UK Power Cord

2246-5010-1405 XK22 Kiosk HOSP; Equinox 6200M mount, i3; 8GB; 120GB SSD;
Printer; Imager; HOSP Win 10 OS, Int Power Cord

2246-5010-3001 XK22 Kiosk HOSP; Single-sided; i3; 8GB; 120GB SSD; Printer; Imager;
VX820; HOSP Win 10 OS, uNav

2246-5010-3004 XK22 Kiosk HOSP; MSR, uNav, i3; 8GB; 120GB SSD; Printer; Imager;
HOSP Win 10 OS, US Power Cord

2246-5010-3005 XK22 Kiosk HOSP; Equinox 6200M mount, uNav, i3; 8GB; 120GB SSD;
Printer; Imager; HOSP Win 10 OS, US Power Cord
NCR SelfServ™ XK22 (2246) Site Preparation Guide 3

Customer Responsibilities
Before the system can be installed, the customer must do or provide the following:

• When required by NCR, provide the NCR Customer Services representative with
appropriate drawings that indicate:

• Location of the equipment

• Site wiring (power and communications, paths and lengths)

• Location of other equipment that may generate electrical noise, electromagnetic


interference, or heat

• Make building alterations necessary to meet wiring and other site requirements.

• Provide and install all communications cables, wall jacks, special connectors, and
associated hardware.

• Provide and install necessary power distribution boxes, conduits, grounds, lightning
protection devices, and associated hardware.

• Make sure all applicable codes, regulations, and laws (including, but not limited to,
electrical, building, safety, and health) are met.

• Provide and install auxiliary power or other equipment as required.

• Provide storage or service areas as required.

• Meet all system/unit environmental requirements.

• Provide and install floor coverings and environmental systems that limit or control static
electricity build-up and discharge.

In general, keep the NCR equipment area free from dust, smoke, lint, and other particles.
Restrict smoking, eating, and drinking around the equipment. Avoid locating the equipment
near other machines that generate ink, carbon, and paper dust particles.
4 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Third Party Peripheral Certification


Third party peripherals must be certified with the NCR SelfServ™ XK22 (2246) Kiosk or a
potential ESD issue can occur. Third party peripherals include any electrically powered devices
connected to the kiosk that are not an NCR branded product or a certified solution advocated
by NCR. Examples of third party products include PIN pad devices, printers, external CD-ROM
drives, and so forth.

Peripherals tend to be less sensitive to electrostatic damage when directly grounded through
their power cords. If the peripheral is powered by the terminal and has no dedicated ground,
then all of the ESD energy is coupled into the port connection. Some devices may require the
use of an in-line galvanic isolator/surge protector in order to prevent problems.

The NCR TPP/SCER process is designed to evaluate third party peripherals and determine
whether additional protective devices are needed.

The NCR Workstation and Peripherals AC Wiring Guide (BST0–2115–53) contains additional
information on this subject.
NCR SelfServ™ XK22 (2246) Site Preparation Guide 5

Environmental Requirements
Barometric Pressure
The NCR SelfServ™ XK22 (2246) Kiosk operates within the following barometric pressure
conditions.

• Maximum operating altitude: 3,000 m (9,843 ft)

• Operating range of pressure: 105 to 69 kPa (15.2 to 20.0 lb./in.)

Temperature
The NCR SelfServ™ XK22 (2246) Kiosk operates over the following temperature ranges. Avoid
continuous operation at or near the indicated temperature extremes, or in locations where the
temperature changes beyond the restrictions.

Temperature Parameter Restriction

Operating 5° to 45° C (41° F to 113° F), dry bulb

Storage -10° to 50° C (14° F to 122° F), three months

Shipping -40° to 60° C (-40° F to 140° F), one week

Humidity
The NCR SelfServ™ XK22 (2246) Kiosk operates within the following humidity ranges. Avoid
continuous operation at or near the indicated humidity extremes, or in locations where the
humidity changes beyond the restrictions. Never expose the kiosk to condensation.

Humidity Type Restriction

Relative 10% to 90%

Maximum Change Rate 10% / 60 minutes

Storage 10% to 90% relative humidity, three months

Shipping 5% to 95% relative humidity, one week


6 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Electrical Requirements
Power Requirements
The Kiosk main power supply has a maximum output of 150 Watts and provides power to the
kiosk and its powered peripherals.

Power (W)
Mode
230V 60Hz 120V 60Hz

Windows Desktop Idle 38.8 39.5

Printing Receipt 77.1 77.9

Running Burn-In (not printing) 68.5 69.3

Running Burn-In (printing) 95.8 95.5

S3 – Sleep** 2.3 2.2

S5 – Off 1.4 1.35

Note: These measurements do not include any EMV pin pad.

** S3 – ACPI is set to S3. S3 uses Sleep command in Windows 10.

Minimum Maximum Input Current


Range Nominal Vrms
Vrms Vrms Maximum Arms

Low (115) 100–127 90 136 1.5 A

High (230 ) 200–240 180 265

AC Wiring Requirements
The customer must provide suitable AC power for the NCR SelfServ™ XK22 (2246) Kiosk and
any associated equipment and devices. NCR recommends a dedicated unswitched power line
dedicated to the NCR equipment installation. Refer to the NCR Workstation and Peripherals AC
Wiring Guide (BST0-2115-23) for store AC wiring requirements. The AC outlet must be
installed near the kiosk and easily accessible to the operator.
NCR SelfServ™ XK22 (2246) Site Preparation Guide 7

LAN Communications
The NCR SelfServ™ XK22 (2246) Kiosk supports Ethernet 10/100/1000baseT Local Area
Network (LAN) communication protocol. Cat-5 wiring for 100baseT or higher is
recommended.

For Ethernet communications wiring specifications, refer to the NCR Ethernet Communication
Wiring Guide (BST0-2118-82).
8 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Transient Protection
AC Power Line Transient Protection
In the process of power distribution, transient electrical energy (including, but not limited to,
lightning strikes, intermittent short circuits, and switching transients) can be introduced onto
power lines. Such transient energy can be very damaging to electronic hardware, and can also
cause data corruption. Under these circumstances, NCR recommends the use of AC power
transient suppressors. Such protection devices are intended to guard against power line
transients that can result in hardware damage and various system or program errors.

Improvement of any deficiencies in power quality is a customer responsibility. Malfunction


and/or component failure as a result of power quality problems are/is not covered by the NCR
Maintenance Agreement. NCR accepts no liability for any such occurrence or for its
consequences.

When power transient suppression is required, the suppressors used should meet the
following minimum requirements:

• Dissipate energy to match the appropriate application categories as defined by IEEE


Standard 587.

• Be of the voltage limiting (clipping), or tracking filter type. The suppressor must not clamp
the voltage to zero, and must self-recover after the passage of the transient. The suppressor
may be of the hybrid type construction that makes use of various technologies in order to
meet speed and dissipation requirements.

• Upon failure, exhibit a positive indication of its failure such as a blown fuse or tripped
breaker.

• Be listed by the accepted safety organization for the country involved (UL, CSA, VDE, ETL,
and so on) and the installation must conform to local, state, and national electrical codes
and regulations.
NCR SelfServ™ XK22 (2246) Site Preparation Guide 9

Data Line Transient Protection


The nature of the transient phenomenon may extend to the data communication lines
connected to this equipment. It is the responsibility of the customer to install and connect a
data line transient suppression system to correct or prevent any deficiencies. Such systems
must meet the following minimum requirements:

• Be of the voltage limiting type and must self-recover after passage of the transient.

• Must be designed to avoid signal degradation for the given interface they are attached to.

• Be installed in accordance with all applicable local, state, and national electrical codes and
regulation.

Note: NCR provides a full line of both AC power and data line transient surge suppressors to
protect your NCR unit and reduce downtime and extend the life of the NCR TouchPort travel
solution. For sizing and product information, please call NCR Site Preparation Services at 800-
257-0458.

The following product offerings are available from NCR Site Preparation Services:

• UPS – Uninterruptible Power Systems

• Provides battery backup for power outages and brownouts.

• Includes AC and data line surge protections.

• If needed, certain models provide basic voltage regulation.

• Small size provides easy installation.

• Line Conditioners / Filters

• Incorporates an Isolation transformer or filter that provides 100% isolation from


disturbances on the incoming AC power line.

• Removes EMI/RFI noise that causes equipment lockups.

• Reduces common mode noise issues and surges/transients.

• Significantly reduces POS downtime and component failure.

• Transient Voltage Surge Suppressors

• Provides protection from catastrophic AC surges/transients.

• Provides data line protection from catastrophic surges that can migrate onto the data
line and network.
10 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Weight
Unit Weight
The following table shows the approximate weights for each NCR XK22 Kiosk configuration.
These values are for reference only. Exact weights are dependent on build configuration.

Kiosk
Kiosk Head Pedestal Baseplate Total Weight
Configuration

Countertop or Wall 26 kg N/A N/A 26 kg (57.32 lb)


(57.32 lb)

Bolted 26 kg 19 kg N/A 45 kg (99.21 lb)


(57.32 lb) (41.89 lb)

Free Standing 26 kg 19 kg 37.2 kg 82.2 kg


(57.32 lb) (41.89 lb) (82.01 lb) (181.22 lb)

Shipping Weight
The following table shows the approximate shipping weights for each NCR XK22 Kiosk part.
These values are for reference only. Exact weights are dependent on build configuration.

Kiosk Part Total Weight

Boxed Countertop + Pallet 43 kg (94.80 lb)

Boxed Pedestal + Pallet 42.6 kg (93.92 lb)


NCR SelfServ™ XK22 (2246) Site Preparation Guide 11

Kiosk Dimensions
The NCR XK22 Kiosk can be installed in different configurations, depending on the features,
kits, and components ordered. Following are dimensions of different NCR XK22 Kiosk
configurations.

Countertop Mount with Small PIN Pad


12 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Countertop Mount with Large PIN Pad


NCR SelfServ™ XK22 (2246) Site Preparation Guide 13

Wall Mount with Small PIN Pad


14 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Wall Mount with Large PIN Pad


NCR SelfServ™ XK22 (2246) Site Preparation Guide 15

Pedestal Mount, Bolted with Small PIN Pad


16 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Pedestal Mount, Bolted with Large PIN Pad


NCR SelfServ™ XK22 (2246) Site Preparation Guide 17

Pedestal Mount, Free Standing with Small PIN Pad


18 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Pedestal Mount, Free Standing with Large PIN Pad


NCR SelfServ™ XK22 (2246) Site Preparation Guide 19

Dual Pedestal Mount, Bolted with Small PIN Pad


20 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Accessibility of Devices
The dimensions in this section show the accessibility of devices for all users especially for
persons with disabilities. Depending on the type of the NCR XK22 Kiosk unit installed, refer to
the following:

Unit Configuration Related Accessibility Information

Countertop Mount Configuration • Heights and Depths (Countertop and Wall Mount
Wall Mount Configuration Configurations) on the facing page
• Distance for Voice Guidance on page 27
Pedestal Mount Configuration • Heights and Depths (Pedestal Mount
Configuration) on page 24
• Distance for Voice Guidance on page 27
NCR SelfServ™ XK22 (2246) Site Preparation Guide 21

Heights and Depths (Countertop and Wall Mount Configurations)


Interface Device Reference Point Height from Ground Depth from front of Door

Touchscreen/Display Top of active display area 1639.8 mm (64.56 in.) 122.9 mm (4.84 in.)

Coupon Chute Center of paper entry slot 1079.4 mm (42.5 in.) 104.5 mm (4.11 in.)

uNav Middle button 1069.4 mm (42.1 in.) 73.3 mm (2.89 in.)

MSR Center of chute 1064 mm (41.89 in.) 65.5 mm (2.58 in.)

PIN Pad No. 5 button 1063.3 mm (41.86 in.) 10.8 mm (0.43 in.)
(Ingenico IPP320 or IPP350)

PIN Pad No. 5 button 1062.3 mm (41.82 in.) 1.6 mm (0.06 in.)
(Verifone VX820 or VX850)

Audio Jack Center 1060.2 mm (41.74 in.) 66.5 mm (2.62 in.)

PIN Pad No. 5 button 1052.5 mm (41.44 in.) -8.8 mm (-0.35 in.)
(Ingenico Lane 3000)

PIN Pad No. 5 button 1046.8 mm (41.21 in.) 2.6 mm (0.10 in.)
(Verifone P400)

NFC Reader Center of scan area 1039.6 mm (40.93 in.) 33.9 mm (1.33 in.)

PIN Pad No. 5 button 1034.6 mm (40.73 in.) 2.38 mm (0.94 in.)
(Equinox 6200M)

PIN Pad No. 5 button 1025.6 mm (40.38 in.) 42.3 mm (1.67 in.)
(Ingenico Lane 5000)

PIN Pad No. 5 button 1013.5 mm (39.9 in.) 50.9 mm (2.00 in.)
(Ingenico iSC250)

PIN Pad No. 5 button 1008.7 mm (39 71 in.) 44.8 mm (1.76 in.)
(Verifone MX915)

PIN Pad No. 5 button 1001.9 mm (39 44 in.) 124.5 mm (4.90 in.)
(Verifone MX925)

Receipt Printer Center of paper exit slot 988.3 mm (38.91 in.) 4.1 mm (0.16 in.)

Barcode Scanner Center of scan area 946.9 mm (37.28 in.) 2.1 mm (0.08 in.)

*The recommended installation height from the ground is 814 mm (32.05 in.).
22 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Height from Ground (Countertop and Wall Mount Configurations)


NCR SelfServ™ XK22 (2246) Site Preparation Guide 23

Depth from Front of Door (Countertop and Wall Mount Configurations)


24 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Heights and Depths (Pedestal Mount Configuration)


Interface Device Reference Point Height from Ground Depth from Front of Base

Touchscreen/Display Top of active display area 1639.8 mm (64.56 in.) 212.4 mm (8.36 in.)

Coupon Chute Center of paper entry slot 1079.4 mm (42.5 in.) 194 mm (7.64 in.)

uNav Middle button 1069.4 mm (42.1 in.) 162.7 mm (6.41 in.)

MSR Center of chute 1064 mm (41.89 in.) 155 mm (6.1 in.)

PIN Pad No. 5 button 1063.3 mm (41.86 in.) 109.8 mm (4.32 in.)
(Ingenico IPP320 or IPP350)

PIN Pad No. 5 button 1062.3 mm (41.82 in.) 97.2 mm (3.83 in.)
(Verifone VX820 or VX850)

Audio Jack Center 1060.2 mm (41.74 in.) 155.9 mm (6.14 in.)

PIN Pad No. 5 button 1052.5 mm (41.44 in.) 80.6 mm (3.17 in.)
(Ingenico Lane 3000)

PIN Pad No. 5 button 1046.8 mm (41.21 in.) 74.7 mm (2.94 in.)
(Verifone P400)

NFC Reader Center of scan area 1039.6 mm (40.93 in.) 123.4 mm (4.86 in.)

PIN Pad No. 5 button 1034.6 mm (40.73 in.) 122.8 mm (4.83 in.)
(Equinox 6200M)

PIN Pad No. 5 button 1025.6 mm (40.38 in.) 131.8 mm (5.19 in.)
(Ingenico Lane 5000)

PIN Pad No. 5 button 1013.5 mm (39.9 in.) 149.9 mm (5.9 in.)
(Ingenico iSC250)

PIN Pad No. 5 button 1008.7 mm (39.71 in.) 143.8 mm (5.66 in.)
(Verifone MX915)

PIN Pad No. 5 button 1001.9 mm (39.44 in.) 124.5 mm (4.90 in.)
(Verifone MX925)

Receipt Printer Center of paper exit slot 988.3 mm (38.91 in.) 93.6 mm (3.69 in.)

Barcode Scanner Center of scan area 946.9 mm (37.28 in.) 91.6 mm (3.61 in.)
NCR SelfServ™ XK22 (2246) Site Preparation Guide 25

Height from Ground (Pedestal Mount Configuration)


26 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Depth from Front of Base (Pedestal Mount Configuration)


NCR SelfServ™ XK22 (2246) Site Preparation Guide 27

Distance for Voice Guidance


This section provides the distance from the center of the Audio Jack to the reference point of
each interface device that is installed on the NCR XK22 Kiosk unit. The direction from the
Audio Jack to the interface devices is based on a 12-hour clock position relative to the center of
the clock, which is the center of the Audio Jack.

Example: 12 o'clock means above the Audio Jack, 3 o'clock means to the right of the Audio
Jack, 6 o'clock means below the Audio Jack, and 9 o'clock means to the left of the Audio Jack.

Direction

Distance between Interface Devices and Audio


Interface Device Reference Point
Jack (Point to Point)

Audio Jack Center

Receipt Printer Center of paper exit slot 6 89.8 mm (3.54 in.)

Barcode Scanner Center of scan area 5 200 mm (7.87 in.)

NFC Reader Center of scan area 4 170 mm (6.69 in.)

PIN Pad No. 5 button 4 404.0 mm (15.91 in.)


(Ingenico Lane 5000)

PIN Pad No. 5 button 4 408.4 mm (16.08 in.)


(Verifone MX915)

PIN Pad No. 5 button 4 432.2 mm (17.02 in.)


(Verifone MX925)

MSR Center of chute 3 248.8 mm (9.8 in.)

PIN Pad No. 5 button 3 253.5 mm (9.98 in.)


(Ingenico IPP320 or
IPP350)

PIN Pad No. 5 button 3 256.5 mm (10.10 in.)


(Verifone P400)

PIN Pad No. 5 button 3 263.3 mm (10.37 in.)


(Ingenico Lane 3000)

PIN Pad No. 5 button 3 300 mm (11.81 in.)


(Verifone VX820 or
VX850)
28 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Direction

Distance between Interface Devices and Audio


Interface Device Reference Point
Jack (Point to Point)

PIN Pad No. 5 button 3 300 mm (11.81 in.)


(Equinox 6200M)

PIN Pad No. 5 button 3 382.4 mm (15.06 in.)


(Ingenico iSC250)

Coupon Chute Center of paper entry slot 2 122.2 mm (4.81 in.)

uNav Middle button 2 37.3 mm (1.47 in.)

Touchscreen/Display Top of active display area 1 572.6 mm (22.54 in.)


NCR SelfServ™ XK22 (2246) Site Preparation Guide 29

Interface Devices
30 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Service Clearance
Kiosk with Small PIN Pad

Kiosk with Large PIN Pad


NCR SelfServ™ XK22 (2246) Site Preparation Guide 31

Countertop Mounting Details


Refer to the following sections for information on NCR XK22 Kiosk Countertop Mount
installation:

• Recommended Bolt Specifications on the next page

• Mounting Dimensions on page 33

• Cable Routing Options on page 34


32 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Recommended Bolt Specifications


In Countertop Mount installation, the kiosk must be bolted to the counter top. The counter top
construction determines the type of anchors to use: bolts and nuts, lag bolts, screws, and so
forth. The anchors are not shipped with the kiosk and must be obtained locally.

NCR recommends to use the following bolt specifications for NCR XK22 Kiosk Countertop
Mount:

• Flanged Hex Head Bolt

• Thread size— M8 (5/16 in.)

• Length — 45 mm (1.77 in.)

Note: Longer bolts are required if the counter top board thickness is greater than
25 mm (0.98 in.).

• Quantity — 4 pieces

• Steel Flat Washer

• Inside diameter — 8.4 mm (0.33 in.)

• Outside diameter — 16 mm (0.63 in.)

• Thickness — 1.4 to 1.8 mm (0.055 to 0.071 in.)

• Quantity — 4 pieces

• Serrated Flange Locknut

• Thread size — M8 (5/16 in.)

• Quantity — 4 pieces
NCR SelfServ™ XK22 (2246) Site Preparation Guide 33

Mounting Dimensions
This section provides recommended dimensions for the Power/LAN cable passage cutout (if
cables are routed under the countertop) and distances for bolt holes.
34 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Cable Routing Options


In Countertop Mount installation, cables may be routed either through the back of the kiosk or
under the countertop.
NCR SelfServ™ XK22 (2246) Site Preparation Guide 35

Wall Mounting Details


Refer to the following sections for information on NCR XK22 Kiosk Wall Mount installation:

• Recommended Bolt Specifications on the next page

• Mounting Dimensions on page 37

• Cable Routing Options on page 39


36 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Recommended Bolt Specifications


In Wall Mount installation, the type of screws used for installation depends on the type of wall
the kiosk will be mounted on.

Concrete Wall Installation


For a concrete wall installation, NCR recommends to use the following bolt specifications:

• Removable Bolt Anchor

• Diameter — M10 (3/8 in.)

• Length — 57.15 mm (2-1/4 in.)

• Thread size — M8 (5/16 in.)

• Quantity — 6 pieces

Dry Wall Installation


For a dry wall installation, NCR recommends to use the following anchor and bolt
specifications:

• Flanged Hex Head Bolt

• Thread size— M10 (3/8 in.)

• Length — 63.5 mm (2-1/2 in.)

• Quantity — 6 pieces

• Toggle Anchor

• Thread size — 3/8 inches - 16

• Quantity — 6 pieces
NCR SelfServ™ XK22 (2246) Site Preparation Guide 37

Mounting Dimensions
This section provides recommended dimensions for the Power/LAN cable passage cutout (if
cables are routed through the cable access cutout on the wall) and recommended height from
the floor to bolt holes.
38 NCR SelfServ™ XK22 (2246) Site Preparation Guide
NCR SelfServ™ XK22 (2246) Site Preparation Guide 39

Cable Routing Options


In Wall Mount installation, cables may be routed either through the cable access cutout on the
wall or through the base of the kiosk enclosure.
40 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Pedestal Mounting Details


Refer to the following sections for information on NCR XK22 Kiosk Pedestal Mount installation:

• Recommended Bolt Specifications on the facing page

• Mounting Dimensions on page 42

• Cable Routing Options on page 43


NCR SelfServ™ XK22 (2246) Site Preparation Guide 41

Recommended Bolt Specifications


Note: The recommended bolt specifications indicated in this section are for Bolted Pedestal
Mount installation only. For Free Standing Pedestal Mount installation, the bolts are already
included in the Baseplate Kit.

In Bolted Pedestal Mount installation, the kiosk pedestal is bolted to the floor and cannot be
transferred from one location to another. This option requires drilling bolt holes on the floor.

Note: The anchors are not shipped with the kiosk and must be obtained locally.

NCR recommends to use the following bolt specifications for NCR XK22 Kiosk Bolted Pedestal
Mount:

• Removable Bolt Anchor

• Diameter — M10 (3/8 in.)

• Length — 57.15 mm (2.25 in.)

• Thread size — 7.94 mm (5/16 in.), 18 pitch

• Quantity — 4 pieces

• Steel Flat Washer

• Inside diameter — 10.31 mm (0.406 in.)

• Outside diameter — 22.225 mm (0.875 in.)

• Thickness — 1.09 to 1.45 mm (0.043 to 0.057 in.)

• Quantity — 4 pieces
42 NCR SelfServ™ XK22 (2246) Site Preparation Guide

Mounting Dimensions
This section shows distances for pedestal bolt holes.
NCR SelfServ™ XK22 (2246) Site Preparation Guide 43

Cable Routing Options


In Pedestal Mount installation, cables may be routed out of the pedestal either through the
access hole on the back (for single–sided installation) or through the access hole on the right–
hand side (for dual–sided installation).

You might also like