0% found this document useful (0 votes)
15 views5 pages

Design of One Way Slab Modified

The document outlines the design calculations for continuous one-way and cantilever slabs, including preliminary data such as slab type, dimensions, and material properties. It details load calculations, reinforcement design, deflection checks, and shear checks, ensuring compliance with IS 456-2000 standards. The design confirms that the provided dimensions and reinforcements are safe for both flexure and shear, with specified reinforcement details for both main and distribution steel.

Uploaded by

bikikrdasks
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views5 pages

Design of One Way Slab Modified

The document outlines the design calculations for continuous one-way and cantilever slabs, including preliminary data such as slab type, dimensions, and material properties. It details load calculations, reinforcement design, deflection checks, and shear checks, ensuring compliance with IS 456-2000 standards. The design confirms that the provided dimensions and reinforcements are safe for both flexure and shear, with specified reinforcement details for both main and distribution steel.

Uploaded by

bikikrdasks
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

DESIGN OF ONE-WAY / CONTINOUS ONE WAY/ CANTILIVER SLABS

Note: Make Changes in yellow cells only and white cells are formulae based
Priliminary Data
Type of slab (456-P37) Continous L/d 26
Shorter Span, Lx (m) 1.2 Longer Span, Ly (m) 5.65
Grade of concrete, M 25 Grade of steel, Fe 500
Dia of bar used (mm) 8 Clear Cover (mm) 20
Support Width (mm) 230
Load Calculation
Density of concrete, 25 KN/m3
Density of B. B. Coba or Floor Finish Material 20 KN/m3
Assumed thickness of slab 120 mm
Effetive depth of Slab 96 mm
Thickness of floor finish 77.5 mm

(a) Self weight 3.00 KN/m2


(b) Floor Finish 1.55 KN/m2
(b) Live Load 3.00 KN/m2
Total Load 7.55 KN/m2
Total Factored Load per meter width, wu 11.33 KN/m
Effective Span IS 456-2000, Cl.22.2
1. Clear Span + Effective depth of slab 1.296 m
2. Clear Span + Width of Support 1.43 m

Mu=𝒘𝒖𝒍𝟐𝒙/𝟖 OR
Hence effective span of slab, Leff 1.296 m

Mu=𝒘𝒖𝒍𝟐𝒙/𝟐 OR 1.99 KN-m

∝𝒅 Wd L2x + ∝𝒍 W𝒍 L2x
Mu=

Check for depth required for flexure, 24.44 mm Distribution Steel

Provided depth is safe in Flexure


Note: In slabs, the depth will mostly be governed by serviceability limit state
criterion of delection.
Reinforcement Design-Main Steel
Minimum Reinforcement (i.e. 0.12% bD) 144.00 mm2
Area of steel required in shoter direction, A st 48.07 mm2
Distribution Steel (Minimum Reinforcement) 144.00 mm2
Position of the Dia. of bar Spacing Spacing Check (IS 456-
Required Provided
reinforcement (mm)
(mm) (mm) 2000,Cl.26.3.3)

Shorter Span 8 349.07 250 OK


(Main Steel)
Longer Span 8 349.07 250 OK
(Distribution Steel)

Check for Deflection (Page.38, Fig. 04)

𝑓𝑠=0.58 𝑓𝑦 (𝐴𝑠𝑡
𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑)/(𝐴𝑠𝑡
69.33 MPa

𝑝𝑟𝑜𝑣𝑖𝑑𝑒𝑑)
Percentage = provided, P t =
of reinforcement 0.21 %
Modification Factor (M.F) [Reff.
Subramanian, Design of One Way Slab Pg.337]
𝐾𝑡 𝑜𝑟 (𝑀.𝐹)=1/(0.225+0.00322 𝑓𝑠−0.625
log_10⁡(𝑏𝑑/100𝐴𝑠𝑡) )

= 2.0000
Now,

((𝑆𝑝𝑎𝑛
(𝑙))/(𝑑𝑒𝑝𝑡ℎ(𝑑)))
= 13.50

(( 𝑆𝑝𝑎𝑛
Safe in Deflection

(𝑙))/(𝑑𝑒𝑝𝑡ℎ(𝑑)))
𝐴𝑐𝑡𝑢𝑎𝑙 = = 52.00


𝑚𝑎𝑥 =
( C ) Development Length

𝛔𝑠)/4Ʈ𝑏
IS 456-2000, Development
Length, Ld

Grade of 𝑑
25 Ʈbd = 2.24 N/mm2
Concret
Required, Ld = 388.39 mm
Provide , Ld = 400.00 mm

Shear Check
Design Shear Force, Vu = 8.81 KN
Nominal Shear Value, Ʈv = 0.092 KN/mm2
Book: "Design of reinforced Concrete", Author: "Subramanian", Chapter: "Design
for Shear"
𝜏𝑐=0.85 √(0.8𝑓𝑐𝑘 ) √((1+5 𝛽𝑠𝑠))-1) / (6 𝛽𝑠𝑠)

𝑊ℎ𝑒𝑟𝑒, 𝛽𝑠𝑠 = ( 0.8 fck ) / (6.89 Pt ) OR 1 which ever is


greater
βss = 14.51
Critical Shear Value, Ʈc = 0.331 N/mm2
As, Ʈv < Ʈc the design is safe in shear
Main Steel 8 mm @ 250 mm c/c
0.1 lx 5.65 mm

0.1 lx

A A

Distribution Steel 8 mm @ 250 mm c/c

Main Steel Ld = 400 mm

Distribution Steel D = 120 mm


Depth of Beam,
Db

1.2 m
230 mm 230 mm

Leff = 1.296 m

Section A-A

(a) Simply Supported Slab


B B

Ld = 400 mm Main Steel 8 mm @ 250 mm c/c

Ds = 120 mm
Depth of Beam,
Db
Distribution Steel 8 mm @ 250 mm c/c

L = 1.2 m

230 mm
Section B-B

(b) Cantilever Slab