0% found this document useful (0 votes)
34 views17 pages

Logic Elements Section

Parker's catalog MSG15-3504 details a range of logic valves designed for versatile applications in hydraulic systems, including poppet and spool types for flow and pressure control. The document outlines various products, their specifications, and applications, emphasizing the advantages of using logic valves to reduce complexity and costs in manifold systems. Additionally, it provides technical tips and examples for implementing directional control circuits using these valves.

Uploaded by

Smolovic Srdjan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
34 views17 pages

Logic Elements Section

Parker's catalog MSG15-3504 details a range of logic valves designed for versatile applications in hydraulic systems, including poppet and spool types for flow and pressure control. The document outlines various products, their specifications, and applications, emphasizing the advantages of using logic valves to reduce complexity and costs in manifold systems. Additionally, it provides technical tips and examples for implementing directional control circuits using these valves.

Uploaded by

Smolovic Srdjan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

Catalog MSG15-3504

Index Logic Elements


CV
SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.
LPM/GPM BAR/PSI

Valves
Check
Technical Tips............................................................................................................................................................. LE2-LE7
SH

POPPET TYPE

Valves
Shuttle
LE101A (NEW).. C10-3S...........Normally Closed, Pilot to Close...............................57/15........ 350/5000.......................... LE8
16SLC1-A............ C16-3S...........Normally Closed, Pilot to Close.............................189/50........ 240/3500.......................... LE9
20SLC1-A............ C20-3S...........Normally Closed, Pilot to Close.............................303/80........ 240/3500........................ LE10 LM

Load/Motor
Controls
FC
SPOOL TYPE
LE102A (NEW).. C10-3S...........Normally Closed, Pilot to Close...............................57/15........ 350/5000........................ LE11

Controls
R06E3................. C16-3S...........Normally Closed, Pilot to Close...........................400/106........ 420/6000........................ LE12

Flow
R08E3................. C20-3S...........Normally Closed, Pilot to Close...........................500/132........ 420/6000........................ LE13
PC

Controls
Pressure
LE102B (NEW).. C10-3S...........Normally Closed, Vent to Open...............................57/15........ 350/5000........................ LE14
LE

Elements
Logic
DC

Directional
Controls
LE103A (NEW).. C10-3S...........Normally Open, Vent to Close.................................57/15........ 350/5000........................ LE15
R06H3................. C16-3S...........Normally Open, Vent to Close...............................160/42........ 420/6000........................ LE16
SV

Solenoid
Valves
PV
LE103B (NEW).. C10-3S...........Normally Open, Vent to Close.................................57/15........ 350/5000........................ LE17

Proportional
Valves
CE
Electronics
Coils &

BC
Bodies &
Cavities

TD
Technical
Data

LE1 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
INTRODUCTION:
Parker’s logic valves offer system designers a versatile range of screw-in elements that, when used in the proper

Valves
combinations, can provide flexible design solutions for many common cartridge valve applications. They offer

Check
system designers the advantage of applying cartridge valve technology in applications where the flow and
pressure conditions may exceed the limits of typical cartridge valves. Logic valves are essentially high flow SH
poppet or spool elements that are controlled by small pilot devices. They can be used to control flow, pressure,
or direction, and when applied in the proper arrangements, can perform multi-task control functions. Parker’s

Valves
Shuttle
logic valves offer system designers alternative products that can help reduce the size, cost, and complexity of
integrated manifold systems.
LM

Load/Motor
NEW PRODUCTS:

Controls
Parker Logic Valves are offered in two basic categories:
Poppet and Spool. FC

Controls
Poppet Type - Used for flow switching directional Spool Type - Used for pressure sensing in modulating

Flow
control applications. applications to regulate flow and pressure.
PC

Controls
Pressure
(1) (1)
LE

Elements
(2) (3) (2) (3)

Logic
DC

Directional
Controls
PRODUCT TYPES / APPLICATIONS Vent-to-open logic valves:
POPPET TYPE Vent-to-open logic valves are primarily used for uni-
directional switching applications. The poppet in the SV
vent-to-open logic valve is spring biased to the closed
Poppet type logic valves are 3 condition. The pilot oil source that operates the logic

Solenoid
Valves
Port 3
ported, 2-way on/off valves that element is generated internally by direct pressure
A3 switch flow between port 1 and from either work port 1 or 2, depending on the option
port 2. The poppet’s on/off chosen. Venting the pilot oil at port 3 allows the valve PV
action is operated by controlling to open and pass flow between port 1 and 2 at the

Proportional
pilot oil at port 3 of the valve. A bias spring setting. Blocking the pilot at port 3 causes

Valves
Port 2 A2 A2
small low flow solenoid or pilot the valve to close. When closed, the 2:1 ratio poppet
A1 valve is an ideal control for this design provides a positive low leak seal. Because the
purpose. Parker offers vent-to- CE
Port 1 pilot source is generated internally within the valve,
open and pilot-to-close style
Electronics
vent-to-open logic valves are best suited for uni-
A1 + A2 = A3 poppet logic valves.
Coils &

directional applications.
Port 3 Port 3
Note: Poppet logic valves are an unbalanced 2:1 ratio BC
poppet design. The opening and closing of the poppet
is dependent on the force balances on the areas of the
Bodies &
Cavities

poppet at port 1, port 2, and port 3. .030 .030


Port 2 Port 2
TD
Vent-to-open Vent-to-open
Internal pilot Internal pilot
Technical

generation Port 1 generation Port 1


from port 1 from port 2
Data

Uni-directional flow, port 1 to 2. Uni-directional flow, port 2 to 1.

LE2 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
POPPET TYPE Continued 2-way, 3-way, and 4-way Directional Control:
Poppet logic valves are typically used to perform high

Valves
Pilot-to-close logic valve: flow directional switching operations using small low

Check
Pilot-to-close logic elements are primarily used for bi- power pilot valves to control the sequence of the
directional flow switching applications. The poppet in directional operation. SH
the pilot-to-close logic valve is spring biased to the
closed condition. With no pilot signal at port 3, the • A single logic valve can be used to control 2-way,

Valves
Shuttle
valve will open allowing flow in either direction on/off switching.
between work ports 1 and 2 once pressure at one of • Multiple elements in a bridge arrangement can
the work ports reaches the biased spring setting. control 3-way or 4-way directional switching. LM
Appling a sufficient externally generated pilot force to • Since each logic valve is individually controlled, the

Load/Motor
Controls
port 3 of the valve closes the poppet creating a low timing, sequence, and overlap of directional
leak seal between port 1 and port 2. functions can be controlled very precisely.
• Uni-directional or bi-directional flow can be
FC
Port 3 achieved, depending on the valve selected.
• Flows in excess of 80 gpm can be controlled

Controls
through a single logic element, and more than one

Flow
logic valve can be used in parallel to control flow in
excess of the rated flow of a single element. PC
Port 2 • Poppet construction provides a low leak directional
control.

Controls
Pressure
Pilot-to-close
External pilot required Port 1
Bi-directional flow, port 1 to 2. (See circuit examples on pages LE5-LE6)
LE

Elements
Logic
SPOOL TYPE DC

Directional
Controls
Spool type logic valves can also be used for Flow Control / Compensators:
directional switching, however, they are typically used Parker offers two types of logic valves for flow control
in modulating applications to control flow or regulate functions. SV
pressure. Virtually any pressure or flow control 1) Normally open spools function as a restrictive type
function can be achieved with a spool type logic valve compensator.

Solenoid
including; restrictive or priority flow control, pressure 2) Normally closed spools function as a priority or by-

Valves
relief, pressure reducing, sequencing, and unloading. pass compensator.
PV
The spools in this category of logic valves are Port 3 Port 3

Proportional
balanced designs; the spool area at the work port

Valves
(port 1) and the pilot port (port 3) are equal (1:1). The
spool is held in a biased condition by a spring. Venting
Port 2 Port 1 Port 1 Port 2
the pilot at port 3 creates an unbalanced condition CE
causing the valve spool to modulate open or close, Electronics

depending on the valve chosen. This spool design


Coils &

makes the valve vary stable because the forces acting


to open and close the valve are in balance.
Normally open spool Normally closed spool BC
Bodies &
Cavities

TD
Technical
Data

LE3 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
Restrictive Flow Regulator: Priority / Bypass Flow Regulator:
Normally open spool type logic elements can be used A logic valve with a normally closed spool can

Valves
with an external orifice or valve as a compensator be used as a priority or by-pass compensator. In

Check
to regulate flow. Used as restrictive compensator, a this case, the spool modulates open to maintain a
normally open spool senses the upstream and down- constant pressure drop across the controlled orifice SH
stream pressure across an orifice or valve. The spool or valve, thereby maintaining a constant priority flow
modulates closed to maintain a constant pressure regardless of upstream or downstream pressure

Valves
Shuttle
drop across the controlled device equal to the bias changes. In a priority arrangement, any oil that
spring in the logic valve, thus maintaining a constant doesn’t saturate the controlled device is by-passed at
flow rate regardless of changes in upstream or load pressure plus the value of the bias spring in the LM
downstream pressure. logic valve.

Load/Motor
Controls
Regulated Regulated
Supply Flow
Dampening By-pass FC
Supply Orifice to Tank

Controls
Flow
Direction of Flow

Direction of Flow PC

Controls
Pressure
Pressure Control:
LE
Spool type logic valves can be used as the main stage Port 3 Port 3
spool in high flow pressure control applications with

Elements
the logic valve handling the high flow, and a small pilot

Logic
valve controlling the action of the logic valve spool.
Port 2 Port 1 Port 1 Port 2
Normally open, and normally closed spool options are DC
available enabling virtually all pressure control

Directional
functions to be achieved. When used in pressure

Controls
control applications, the logic valve spool modulates
open or closed to maintain the pressure setting of the
pilot valve communicated to port 3. Pressure control Normally open spool Normally closed spool SV
applications require a pilot connection between the • Pressure • Relief
Reducing • Sequence
control port (port 1 or 2), and the pilot port (port 3). In

Solenoid
Valves
• Unloading
order to simplify the design, Parker offers spool type
logic valves with internal piloting options that can help
minimize the number of connections needed. When (See circuit examples on page LE7) PV
used in manifold systems, the internal piloting options

Proportional
help to simplify the manifold design by reducing the

Valves
number of construction drillings in the block. Multiple
functions such as relief, pump unloading, and pres- Application Note:
This section is as an application guide, and it is intended to CE
sure compensation can be performed with one logic illustrate the various ways that logic elements can be used to create Electronics
valve by communicating multiple pilot devices to the a variety of hydraulic control functions. For additional help applying
same logic element.
Coils &

logic valves, contact your Parker Sales Engineer.

BC
Bodies &
Cavities

TD
Technical
Data

LE4 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
DIRECTIONAL CONTROL EXAMPLES

Valves
2-position, 2-way 2-position, 2-way

Check
Pilo t Pilot
normally open example. Directional normally open example. Directional
Valve Valve
Switched by 2-position, Pilot Switched by external
3-way pilot valve and Pressure pilot pressure and SH
external pilot pressure. Source vented through
2-position, 2-way

Valves
Shuttle
pilot valve.
LE102A LE102B
Logic Element Logic Element LM

Load/Motor
Controls
Direction of Flow Direction of Flow
FC

2-position, 2-way 2-position, 2-way

Controls
Pilot P ilot
normally open example. Directional normally open example. Directional

Flow
Valve
Internal pilot generation. Valve Internal pilot generation.
PC

Controls
Pressure
LE102B LE101B
Logic Element Logic Element
LE

Elements
Direction of Flow

Logic
Direction of Flow
DC
2-position, 2-way P ilot

Directional
normally open example.

Controls
Directional
Valve
Switched by 2-position,
3-way pilot valve and
external pilot. SV

Solenoid
Valves
LE101A
Logic Element
PV

Proportional
Direction of Flow

Valves
CE
**SLC1A logic element. P ilot **SLC1A logic element. P ilot Electronics
With shuttle-selected Directional Valve External pilot supply and Directional
Valve
pilot supply. 2-position, 2-way pilot
Coils &

directional valve. Fi xed


Restrictor
P ilot
Source BC

LE101A
Bodies &
Cavities

Logic Element
LE101A
Logic Element
TD
P ilot S huttle Valve
Direction of Flow
Technical

Direction of Flow
Data

LE5 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
DIRECTIONAL CONTROL EXAMPLES
THREE-WAY BRIDGE CIRCUITS

Valves
Check
Circuit 1, with LE101A Circuit 2, with LE102A Circuit 3, with LE102A
poppet logic element. spool logic element. spool logic element.
C PB C C SH
PA
PA PB PA PB

Valves
B

Shuttle
A B A B

A LM
Pilot Pressure Available Pilot Pressure Available

Load/Motor
Required Required

Controls
Applied To From Circuit Applied To From Circuit
Flow Path Flow Path
PA PB 1 2 3 PA PB 1 2 3
A B A B
FC
NO NO X X NO YES X X

Controls
C C
A B

Flow
A B

YES NO X X X NO YES X X NOTE: Pilot pressure must


exceed load pressure in PC
C
C order for valve to close.

Controls
Pressure
FOUR-WAY BRIDGE CIRCUITS
Circuit 1, with LE101A poppet logic elements. Circuit 2, with LE102A spool logic elements.
P2 P3 P2 P3
LE

Elements
A B

Logic
A B

DC

Directional
Controls
P1 P4

P1 P4
P5 T SV
P T

P P5

Solenoid
Valves
Required Pilot Pressure Applied To Required Pilot Pressure Applied To Required Pilot Pressure Applied To
Flow Path P1 P2 P3 P4 P5 Flow Path P1 P2 P3 P4 P5 Flow Path P1 P2 P3 P4 P5 PV
A B A B A B

Proportional
YES YES YES YES YES YES NO NO YES YES YES NO YES NO YES

Valves
P T P T P T
A B A B A B CE
NO NO NO NO NO NO YES YES NO YES YES YES YES NO YES Electronics

P T P T P T
Coils &

A B A B A B

YES YES NO NO NO YES YES NO YES YES YES NO YES YES YES BC
P T P T P T
Bodies &
Cavities

A B A B

NO NO YES YES NO NO YES YES YES YES


P T P T TD
A B A B
NOTE: Pilot pressure must
Technical

YES YES YES YES NO NO YES NO YES YES


exceed load pressure in
Data

P T P T order for valve to close.

LE6 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504
Technical Tips Logic Elements
CV
FLOW CONTROL EXAMPLES
Pressure compensated Fix ed or Variable Priority Pressure compensated restrictive

Valves
Check
priority flow control Fl ow Restrictor flow control example.
example. Priority
Fl ow Outlet
Fix ed or Variable
SH
Dampening Restrictor
Inlet Or ifice

Valves
Shuttle
LE102A LE103A
Logic Element Logic Element

Direction of Flow Direction of Flow LM

Load/Motor
Load sensing priority flow control example Load sensing priority flow control example

Controls
with pressure limiting and unloading. with pressure limiter.

Pum p Variable Restrictor Load Directional


Pr iority Control Valve FC
Outlet
to Load Fix ed or Load

Controls
Pum p Variable
Fix ed Pilot Ser vice
Restrictors Lines

Flow
Restrictor

LE102A PC
Logic Element Pilot
Directional

Controls
Pressure
Valve Fix ed Pilot Pilot
LE102A Restrictor Sensing
Logic Element Checks
Load LE
Pilo t Sense
Relief Bleed

Elements
Pressure Limiter Valve
Pilot Relie f Valve

Logic
Direction of Flow
Direction of Flow DC

Directional
Controls
PRESSURE CONTROL EXAMPLES
Pressure relief or sequence example with Pressure relief or sequence example with
external pilot supply and pilot relief. internal pilot supply and pilot relief. SV
Fi xed Pilot Relief Pilot Relie f
Pilot Restrictor Valve Valve

Solenoid
Valves
Pressure
Source

PV

Proportional
LE102A LE102B

Valves
Logic Element Logic Element

Direction of Flow Direction of Flow


CE
Pressure reducing example, non-relieving type. Pressure reducing-relieving example. Electronics
Pilot Relief
Valve Pilot Relief
Coils &

Valve
LE102A
Logic Element
BC
Bodies &
Cavities

System
LE103B
TD
Logic Element LE103B
Logic Element
Technical
Data

Direction of Flow Direction of Flow

LE7 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Poppet Type, Logic Valve
NEW
Product Information Series LE101A2 2 1

CV
1" Hex.
22-27 Nm
General Description 11.2 [0.44]
(16-20 lb. ft.)
Torque

Poppet Type, Bi-Directional, Normally Closed, Pilot to 11.2 [0.44]

Valves
Check
Close Logic Element. For additional information see B 7/8-14 UNF-2A
Thread

Technical Tips on pages LE2-LE7.


B SH
3 3
Features 47.0 [1.85]

• Hardened, precision ground parts for durability

Valves
Shuttle
3
• Low leakage design 2 2

• All external parts zinc plated 47.0 [1.85]


LM
• Port 2 to 1 is the preferred flow path (3)

Load/Motor
1 1
• “D”-Ring eliminates backup rings

Controls
2
A
(2)

Specifications FC
(1) (3)
Rated Flow 57 LPM (15 GPM) 1
Dimensions

Controls
HYDRAULIC SCHEMATIC

Maximum Inlet 2 1
350 Bar (5000 PSI)

Flow
DFCD-1009A Rev 07 2018-08

Pressure A
(2)
Leakage at 5 drops/min. (.33 cc/min.) PC
150 SSU (32 cSt) @ 240 Bar (3500 PSI)
(1)

Controls
All parts steel. All operating parts

Pressure
Cartridge Material
hardened steel. HYDRAULIC SCHEMATIC

-37°C to +93°C (“D”-Ring) 2


(-35°F to +200°F)
LE
Operating Temp. -34°C to +121°C (Nitrile) Millimeters (Inches)

Elements
Range/Seals (-30°F to +250°F)
-26°C to +204°C (Fluorocarbon) Performance Curves

Logic
(-15°F to +400°F)
Pressure Drop, P2-P1 vs. Flow (Through cartridge only)
Mineral-based or synthetic with Hydraulic Oil 150 SSU @ 100F (32cSt) DC
Fluid Compatibility/
lubricating properties at viscosities
Viscosity

Directional
of 45 to 2000 SSU (6 to 420 cSt)

Controls
Filtration ISO-4406 18/16/13, SAE Class 4
Approx. Weight 0.14 kg (0.3 lbs.) SV
C10-3S
Cavity

Solenoid
(See BC Section for more details)

Valves
PV
Ordering Information

Proportional
Valves
LE101A Flow (Q)

Pressure Drop, P1-P2 vs. Flow (Through cartridge only) CE


10 Size Bias
Logic Element Spring Hydraulic Oil 150 SSU @ 100F (32cSt) Electronics
Coils &

Highlighted represents preferred options that


offer the shortest lead times. Other options
may be available, but at extended lead times. BC

Code Bias Spring Code Seals


Bodies &
Cavities

02 1.7 Bar (25 PSI) Omit “D-Ring”


04 3.5 Bar (50 PSI)
Kit Part Number TD
05 5.2 Bar (75 PSI) D-Ring Seal SK10-3S
07 6.9 Bar (100 PSI)
Technical

Nitrile Seal SK10-3S


Data

10 10.3 Bar (150 PSI) Fluorocarbon Seal SK10-3SV


Flow (Q)

LE8 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Poppet Type Logic Valve
Product Information Series 16SLC1-A
CV
General Description
Poppet Type, Bi-Directional, Normally Closed, Pilot to

Valves
Check
Close Logic Element. For additional information
see Technical Tips on pages LE2-LE7.
SH
(3)
Features
• Hardened, precision ground parts for durability

Valves
Shuttle
• Polyurethane seals only (2)
• No backup rings LM
• Low leakage design

Load/Motor
(1)
• All external parts zinc plated

Controls
(3)

• Port 2 to 1 is the preferred flow path


FC
Performance Curve (2)

Pressure Drop vs. Flow (Through cartridge only)

Controls
Flow
(1)
PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
200 13.8
Dimensions Millimeters (Inches) PC
36.5
Pressure Drop ( P)

Controls
150 10.3 (1.44)

Pressure
55.7
(2.19)
100 6.9
(2) (3) LE

Elements
50 3.4
(1)

Logic
0
LPM 38 76 114 151 189
0 DC
GPM 10 20 30 40 50
Flow (Q) 1-1/2" Hex.

Directional
1 5/16-12 UN-2A

Controls
54 Nm
Thread (40 lb . ft.)
Torque
Specifications
SV
Rated Flow 189 LPM (50 GPM) Ordering Information
Maximum Inlet

Solenoid
Valves
Pressure
240 Bar (3500 PSI)
16SLC1 A
Leakage at 5 drops/min. (.33 cc/min.) 16 Size Poppet Bias PV
150 SSU (32 cSt) @ 240 Bar (3500 PSI) Logic Element Bi-Directional Spring

Proportional
All parts steel. All operating parts
Cartridge Material

Valves
hardened steel. Highlighted represents preferred options that
offer the shortest lead times. Other options
-37°C to +107°C (Polyurethane,EPS) may be available, but at extended lead times.
Operating Temp. (-35°F to +225°F) CE
Range/Seals -26°C to +204°C (Fluorocarbon) Electronics
(-15°F to +400°F)
Code Bias Spring Code Seals
Coils &

Mineral-based or synthetic with 100 6.9 Bar (100 PSI) Omit Polyurethane, EPS
Fluid Compatibility/
lubricating properties at viscosities
Viscosity 150 10.3 Bar (150 PSI)
of 45 to 2000 SSU (6 to 420 cSt) BC
Filtration ISO-4406 18/16/13, SAE Class 4
Bodies &
Cavities

Approx. Weight 0.33 kg (0.78 lbs.)


C16-3S
Cavity TD
(See BC Section for more details)
Kit Part Number
Technical

Polyurethane, EPS Seal WRK-16-3S


Data

Fluorocarbon Seal WRK-16-3S-W

LE9 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Poppet Type Logic Valve
Product Information Series 20SLC1-A
CV
General Description
Poppet Type, Bi-Directional, Normally Closed, Pilot to

Valves
Check
Close Logic Element. For additional information see
Technical Tips on pages LE2-LE7. (3)
SH
Features
• Hardened, precision ground parts for durability

Valves
Shuttle
• Polyurethane seals only (2)

• No backup rings LM
• Low leakage design
(1)

Load/Motor
• All external parts zinc plated

Controls
(3)

• Port 2 to 1 is the preferred flow path


FC
(2)
Performance Curve

Controls
Pressure Drop vs. Flow (Through cartridge only)

Flow
(1)
PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
100 6.9 Dimensions Millimeters (Inches) PC
43.8
Pressure Drop ( P)

80 5.5

Controls
(1.72)

Pressure
76.2
60 4.1 (3.00)

(2) (3) LE
40 2.8

Elements
20 1.4 (1)

Logic
0
LPM 76 151 227 303 DC
0
GPM 20 40 60 80
Flow (Q) 1-7/8" Hex.

Directional
1 5/8-12 UN-2A

Controls
113 Nm
Thread
(83 lb . ft.)
Torque
Specifications
SV
Rated Flow 303 LPM (80 GPM) Ordering Information
Maximum Inlet

Solenoid
Valves
Pressure
240 Bar (3500 PSI)
20SLC1 A
Leakage at 5 drops/min. (.33 cc/min.) 20 Size Poppet Bias PV
150 SSU (32 cSt) @ 240 Bar (3500 PSI) Logic Element Bi-Directional Spring

Proportional
All parts steel. All operating parts
Cartridge Material

Valves
hardened steel. Highlighted represents preferred options that
offer the shortest lead times. Other options
-37°C to +107°C (Polyurethane,EPS) may be available, but at extended lead times.
Operating Temp. (-35°F to +225°F) CE
Range/Seals -26°C to +204°C (Fluorocarbon) Electronics
(-15°F to +400°F)
Code Bias Spring Code Seals
Coils &

Mineral-based or synthetic with 100 6.9 Bar (100 PSI) Omit Polyurethane, EPS
Fluid Compatibility/
lubricating properties at viscosities
Viscosity 150 10.3 Bar (150 PSI)
of 45 to 2000 SSU (6 to 420 cSt) BC
Filtration ISO-4406 18/16/13, SAE Class 4
Bodies &
Cavities

Approx. Weight 0.81 kg (1.78 lbs.)


C20-3S
Cavity TD
(See BC Section for more details)
Kit Part Number
Technical

Polyurethane, EPS Seal WRK-20-3S


Data

Fluorocarbon Seal WRK-20-3S-W

LE10 Parker Hannifin Corporation


HVS and MSDE Divisions
B 2
Catalog MSG15-3504 Spool Type, Logic Valve
NEW
Product Information Series LE102A LE102A
CV
General Description
Spool Type, Normally Closed, Pilot to Close Logic 3 3

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7. B SH
Features 2 2
• High flow capacity

Valves
Shuttle
• Used as high flow switching or metering element
• Can be used as bleed off style pressure compensated 1 31
LM
flow regulator when used with restrictor

Load/Motor
• Various bias spring pressures available

Controls
3 2 3 2
A
• 1:1 pilot pressure ratio
• Hardened working parts for maximum durability 2
FC
• All external parts zinc plated
• “D”-Ring eliminates backup rings

Controls
1 1

Flow
Performance Curve 1
Pressure Drop, vs. Flow (Through cartridge only) Dimensions Millimeters (Inches) PC
Hydraulic Oil 150 SSU @ 100F (32cSt)
A 2 3 2

Controls
Pressure
LE
1

Elements
Logic
2 DC

Directional
Controls
Flow (Q)

SV
Specifications
Rated Flow 57 LPM (15 GPM)

Solenoid
Valves
Ordering Information
Maximum Inlet
350 Bar (5000 PSI)
Pressure
LE102A PV
Leakage at
82 ml/min.@207 Bar (3000 PSI)

Proportional
150 SSU (32 cSt) 10 Size Bias

Valves
Logic Element Spring
All parts steel. All operating parts
Cartridge Material
hardened steel.
Highlighted represents preferred options that CE
-37°C to +93°C (“D”-Ring) offer the shortest lead times. Other options
(-35°F to +200°F)
Electronics
may be available, but at extended lead times.
Operating Temp. -34°C to +121°C (Nitrile)
Coils &

Range/Seals (-30°F to +250°F) Code Bias Spring Code Seals


-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F) 01 1.7 Bar (25 PSI) Omit “D-Ring” BC
Mineral-based or synthetic with 05 3.5 Bar (50 PSI)
Fluid Compatibility/ Kit Part Number
lubricating properties at viscosities
Bodies &
Cavities

07 6.9 Bar (100 PSI) D-Ring Seal SK10-3S


Viscosity
of 45 to 2000 SSU (6 to 420 cSt)
10 10.3 Bar (150 PSI) Nitrile Seal SK10-3S
Filtration ISO-4406 18/16/13, SAE Class 4 15 15 Bar (218 PSI) Fluorocarbon Seal SK10-3SV TD
Approx. Weight 0.02 kg (0.045 lbs.) 20 20 Bar (290 PSI)
Technical

C10-3S
Cavity
Data

(See BC Section for more details)

LE11 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Spool Type Logic Valve
Product Information Series R06E3
CV
General Description
Spool Type, Normally Closed, Pilot to Close Logic

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7.
SH
Features
• High flow capacity

Valves
Shuttle
• Used as high flow switching or metering element
• Can be used as bleed off style pressure compensated
LM
flow regulator when used with restrictor (3)

• More stable than poppet type

Load/Motor
Controls
• Various switching pressures available
• 1:1 pilot pressure ratio (3) (2)
FC
• Hardened working parts for maximum durability
• All external parts zinc plated (1) (2)

Controls
(1)

Flow
Performance Curve (Through cartridge only)
Vented Open Pressure Drop vs. Flow 1 to 2 PC
PSI
290
Bar
20
Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Dimensions Millimeters (Inches)

Controls
Pressure
R06E3-15.0

218 15 55.3 30.5


(2.18) (1.20)
Pressure Drop

R06E3-10.0 LE
145 10 (2) (3)

Elements
Logic
73 5

(1)
0 DC
LPM 100 200 300 400
0
GPM 26.4 52.8 79.3 105.7

Directional
Controls
Flow (Q ) 1-5/16" - 12 UNF
Thread
38 AF Hex.
Specifications 100 Nm (74 lb. ft.)
Torque
SV
Rated Flow 400 LPM (106 GPM)
Nominal Flow @

Solenoid
Valves
270 LPM (71 GPM)
7 Bar (100 PSI) Ordering Information
Maximum Inlet
420 Bar (6000 PSI) PV
Pressure
R06E3 N

Proportional
Leakage at 82cc/min. (5 cu in/min.)

Valves
150 SSU (32 cSt) @ 240 Bar (3000 PSI) 16 Size Switching Seals
Logic Element Pressure
All parts steel. All operating parts
Cartridge Material
hardened steel. CE
-34°C to +121°C (Nitrile)
Electronics
Code Switching Pressure
Operating Temp. (-30°F to +250°F) Non Adjustable Preset
Coils &

Range/Seals -26°C to +204°C (Fluorocarbon)


10.0 10.0 Bar (145 PSI)
(-15°F to +400°F)
15.0 15.0 Bar (218 PSI)
Mineral-based or synthetic with BC
Fluid Compatibility/
lubricating properties at viscosities
Viscosity
of 45 to 2000 SSU (6 to 420 cSt)
Bodies &
Cavities

Code Seals

Filtration ISO-4406 18/16/13, SAE Class 4 N Nitrile

Approx. Weight 0.33 kg (0.78 lbs.) TD


Kit Part Number
C16-3S
Cavity Nitrile Seal SK30508N-1
Technical

(See BC Section for more details)


Data

Fluorocarbon Seal SK30508V-1

LE12 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Spool Type Logic Valve
Product Information Series R08E3
CV
General Description
Spool Type, Normally Closed, Pilot to Close Logic

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7.
SH
Features
• High flow capacity

Valves
Shuttle
• Can be used as high flow switching or metering element
• Can be used as bleed off style pressure compensated (3)
LM
flow regulator when used with restrictor
• Various switching pressures available

Load/Motor
Controls
• 1:1 pilot pressure ratio
• Hardened working parts for maximum durability (3)
(2)
FC
• All external parts zinc plated
(1) (2)

Controls
Performance Curve (Through cartridge only) (1)

Flow
Vented Open Pressure Drop vs. Flow 1 to 2
Dimensions Millimeters (Inches)
PC
PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
290 20

Controls
Pressure
R08E3-15.0 SPOT FACE DATUM
74.9 26.1
218 15 (2.95) (1.03)
LE
Pressure Drop

R08E3-10.0
(2) (3)
145 10

Elements
Logic
73 5
(1)
0 DC
LPM 100 200 300 400
0

Directional
GPM 26.4 52.8 79.3 105.7

Controls
Flow (Q ) 1-5/8" - 12 UNF
Thread
Specifications 50 AF Hex.
150 Nm (110 lb. ft.) SV
Torque
Rated Flow 500 LPM (132 GPM)
Nominal Flow @

Solenoid
Valves
340 LPM (90 GPM)
7 Bar (100 PSI)
Ordering Information
Maximum Inlet
420 Bar (6000 PSI) PV
Pressure
R08E3 N

Proportional
Leakage at
82ml/min. @ 240 Bar (3000 PSI)

Valves
150 SSU (32 cSt) 20 Size Switching Seals
All parts steel. All operating parts Logic Element Pressure
Cartridge Material
hardened steel. CE
-34°C to +121°C (Nitrile)
Electronics
Switching Pressure
Operating Temp. (-30°F to +250°F) Code
Non Adjustable Preset
Coils &

Range/Seals -26°C to +204°C (Fluorocarbon)


(-15°F to +400°F) 10.0 10.0 Bar (145 PSI)

Mineral-based or synthetic with 15.0 15.0 Bar (218 PSI) BC


Fluid Compatibility/
lubricating properties at viscosities
Viscosity
of 45 to 2000 SSU (6 to 420 cSt)
Bodies &
Cavities

Code Seals

Filtration ISO-4406 18/16/13, SAE Class 4 N Nitrile

Approx. Weight 0.69 kg (1.52 lbs.) TD


Kit Part Number
C20-3S
Cavity
Technical

(See BC Section for more details) Nitrile Seal SK30512N-1


Data

Fluorocarbon Seal SK30512V-1

LE13 Parker Hannifin Corporation


HVS and MSDE Divisions
2
Catalog MSG15-3504 Spool Type, Logic Valve
NEW
Product Information Series LE102B LE102A
CV
General Description
Spool Type, Normally Closed, Vent to Open Logic

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7. B SH
Features
• High flow capacity
• Used

Valves
Shuttle
as high flow switching or metering element
• Can be used as main stage for a pilot operated relief
or sequence valve LM
• Various bias
Integral pilot flow filter 3
• 1:1 pilot pressure
spring pressures available

Load/Motor
• Hardened workingratio

Controls
• All external parts zinc
parts for maximum durability
• “D”-Ring eliminates backupplated
FC
• rings 2
Performance Curve

Controls
Pressure Drop, vs. Flow (Through cartridge only)

Flow
Hydraulic Oil 150 SSU @ 100F (32cSt)
1
Dimensions Millimeters (Inches) PC
3 2
A

Controls
Pressure
LE
1

Elements
Logic
2 DC
Flow (Q)

Directional
Specifications

Controls
Rated Flow 57 LPM (15 GPM)
SV
Maximum Inlet 350 Bar (5000 PSI)
Pressure

Solenoid
Valves
Leakage @
150 SSU (32 cst) 82 ml/min.@207 Bar (3000 PSI)

Ordering Information PV

LE102B

Proportional
Cartridge Material All parts steel. All operating
parts hardened steel.

Valves
10 Size Bias
Operating Temp. -37°C to +93°C (“D”-Ring) Logic Element Spring
Range/Seals (-35°F to +200°F) CE
-34°C to +121°C (Nitrile)
Highlighted represents preferred options that
Electronics
(-30°F to +250°F)
offer the shortest lead times. Other options
-26°C to +204°C (Fluorocarbon)
Coils &

may be available, but at extended lead times.


(-15°F to +400°F

Fluid Mineral-based or synthetic with Code Bias Spring Code Seals BC


Compatibility/ lubricating properties at viscosities 01 1.7 Bar (25 PSI) Omit “D-Ring”
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Bodies &
Cavities

05 3.5 Bar (50 PSI)


Kit Part Number
Filtration ISO-4406 18/16/13, 07 6.9 Bar (100 PSI)
SAE Class 4 D-Ring Seal SK10-3S
10 10.3 Bar (150 PSI) Nitrile Seal SK10-3S TD
Approx. Weight .14 kg (.30 lbs.)
15 15 Bar (218 PSI) Fluorocarbon Seal SK10-3SV
Technical

Cavity C10-3S 20 20 Bar (290 PSI)


Data

(See BC Section for more details)

LE14 Parker Hannifin Corporation


HVS and MSDE Divisions
B
2
Catalog MSG15-3504 Spool Type, Logic Valve
NEW
Product Information Series LE103A LE103A
CV
General Description
3 3
Spool Type, Normally Open, Vent to Close Logic

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7.
B SH
Features 2 2
• High flow capacity

Valves
Shuttle
• Used as high flow switching or metering element
• Can be used for inline pressure compensated flow 1 1 LM
control when used with restrictor (refer to application) 3
• Various bias spring pressures available

Load/Motor
Controls
A (3) (1) (1)

• 1:1 pilot pressure ratio


• Hardened working parts for maximum durability FC
• All external parts zinc plated 2
• “D”-Ring eliminates backup rings

Controls
(2) (3) (2)

Flow
Performance Curve 1
Pressure Drop, vs. Flow (Through cartridge only) Dimensions Millimeters (Inches) PC
Hydraulic Oil 150 SSU @ 100F (32cSt) 2
A (3) (1)

Controls
Pressure
LE

Elements
(2)

Logic
2 DC

Directional
Controls
Flow (Q)
SV
Specifications
Rated Flow 57 LPM (15 GPM)

Solenoid
Valves
Maximum Inlet
Pressure
350 Bar (5000 PSI) Ordering Information
PV
Leakage at
82 ml/min.@207 Bar (3000 PSI) LE103A

Proportional
150 SSU (32 cSt)

Valves
All parts steel. All operating parts 10 Size Bias
Cartridge Material Logic Element Spring
hardened steel.
CE
-37°C to +93°C (“D”-Ring)
(-35°F to +200°F) Highlighted represents preferred options that Electronics

Operating Temp. -34°C to +121°C (Nitrile) offer the shortest lead times. Other options
Coils &

(-30°F to +250°F) may be available, but at extended lead times.


Range/Seals
-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F) Code Bias Spring Code Seals BC
Mineral-based or synthetic with 01 1.7 Bar (25 PSI) Omit “D-Ring”
Fluid Compatibility/
lubricating properties at viscosities
Bodies &
Cavities

05 3.5 Bar (50 PSI)


Viscosity Kit Part Number
of 45 to 2000 SSU (6 to 420 cSt)
07 6.9 Bar (100 PSI) D-Ring Seal SK10-3S
Filtration ISO-4406 18/16/13, SAE Class 4 10 10.3 Bar (150 PSI) Nitrile Seal SK10-3S TD
Approx. Weight 0.14 kg (0.3 lbs.) 15 15 Bar (218 PSI) Fluorocarbon Seal SK10-3SV
Technical

C10-3S 20 20 Bar (290 PSI)


Cavity
Data

(See BC Section for more details)

LE15 Parker Hannifin Corporation


HVS and MSDE Divisions
Catalog MSG15-3504 Spool Type Logic Valve
Product Information Series R06H3
CV
General Description
Spool Type , Normally Open, Vent to Close Logic

Valves
Check
Element. For additional information see Technical Tips
on pages LE2-LE7.
SH
Features
• High flow capacity

Valves
Shuttle
• Used as high flow switching or metering element
• Can be used for inline pressure compensated flow
LM
control when used with restrictor (refer to application) (3)
• More stable than poppet type

Load/Motor
Controls
• Range of spring ratings available
• 1:1 pilot ratio (3) (2)
FC
• Hardened working parts for maximum durability
• All external parts zinc plated (2) (1)

Controls
(1)
Performance Curve

Flow
Pressure Drop vs. Flow (Through cartridge only)
PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
PC
290 20 Dimensions
Millimeters (Inches)

Controls
Pressure
55.3 30.5
Pressure Drop

218 15 (2.18) (1.20)

(2) (3)
145 10 LE
2 to 1

Elements
73 5
(1)

Logic
0
LPM 40 80 120 160
0 DC
GPM 10.6 21.1 31.7 42.3
Flow (Q) 1-5/16" - 12 UNF
Thread

Directional
38 AF Hex.

Controls
100 Nm (74 lb. ft.)
Torque
Specifications
Rated Flow 160 LPM (42 GPM) SV

Nominal Flow @
90 LPM (24 GPM)

Solenoid
Valves
7 Bar (100 PSI) Ordering Information
Maximum Inlet
420 Bar (6000 PSI)
Pressure PV
Leakage at
R06H3 N
125ml/min.

Proportional
150 SSU (32 cSt) @ 100 Bar (1450 PSI) 16 Size Switching Seals

Valves
Logic Element Pressure
Switching Pressure See ordering information
All parts steel. All operating parts CE
Cartridge Material Switching Pressure
hardened steel. Code Electronics
Non Adjustable Preset
-34°C to +121°C (Nitrile)
Coils &

10.0 10.0 Bar (145 PSI)


Operating Temp. (-30°F to +250°F)
Range/Seals -26°C to +204°C (Fluorocarbon) 15.0 15.0 Bar (218 PSI)
(-15°F to +400°F) BC
Mineral-based or synthetic with
Fluid Compatibility/ Code Seals
lubricating properties at viscosities
Bodies &
Cavities

Viscosity N Nitrile
of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO-4406 18/16/13, SAE Class 4 TD
Approx. Weight 0.37 kg (0.82 lbs.) Kit Part Number
Technical

Nitrile Seal SK30508N-1


C16-3S
Cavity
Data

(See BC Section for more details) Fluorocarbon Seal SK30508V-1

LE16 Parker Hannifin Corporation


HVS and MSDE Divisions
23.4 [0.92]
B 2
Catalog MSG15-3504 Spool Type, Logic Valve
NEWLE103A
Product Information Series LE103B LE103B
CV
General Description
3 3
Spool Type, Normally Open, Vent to Close Logic 3

Valves
Check
Element. For additional information see Technical Tips
47.0 [1.85]
on pages LE2-LE7. B 2
SH
Features
• High flow capacity 2 2
2
• Used as high flow switching or metering element

Valves
Shuttle
• Can be used as pressure regulator with mainstage
controlled remotely by a pilot1relief valve or a
3 1 3 LM
proportional valve 1

Load/Motor
• Integral
A pilot flow filter

Controls
(3) (1) (1)
4

• Various bias spring pressures available


• 1:1 pilot pressure ratio 2 2 FC
• Hardened working parts for maximum durability
• All external parts zinc plated

Controls
(2) (3) (2)
• “D”-Ring eliminates backup rings

Flow
1 1
Performance Curve Dimensions Millimeters (Inches) PC
Pressure Drop, vs. Flow (Through
A cartridge
2 only) (3) (1) (1) 1
Hydraulic Oil 150 SSU @ 100F (32cSt)

Controls
Pressure
LE
(2) (3) (2)

Elements
Logic
2 DC

Directional
Controls
Flow (Q) SV
Specifications

Solenoid
Rated Flow 57 LPM (15 GPM)

Valves
Maximum Inlet
Pressure
350 Bar (5000 PSI) Ordering Information
PV
Leakage at
LE103B

Proportional
82 ml/min.@207 Bar (3000 PSI)
150 SSU (32 cSt)

Valves
All parts steel. All operating parts 10 Size Bias
Cartridge Material Logic Element Spring
hardened steel.
CE
-37°C to +93°C (“D”-Ring)
Highlighted represents preferred options that Electronics
(-35°F to +200°F)
offer the shortest lead times. Other options
Operating Temp. -34°C to +121°C (Nitrile)
Coils &

may be available, but at extended lead times.


Range/Seals (-30°F to +250°F)
-26°C to +204°C (Fluorocarbon)
(-15°F to +400°F) Code Bias Spring Code Seals BC
01 1.7 Bar (25 PSI) Omit “D-Ring”
Mineral-based or synthetic with
Fluid Compatibility/
Bodies &
Cavities

lubricating properties at viscosities 05 3.5 Bar (50 PSI)


Kit Part Number
Viscosity
of 45 to 2000 SSU (6 to 420 cSt) 07 6.9 Bar (100 PSI) D-Ring Seal SK10-3S
Filtration ISO-4406 18/16/13, SAE Class 4 10 10.3 Bar (150 PSI) Nitrile Seal SK10-3S TD
Approx. Weight 0.14 kg (0.3 lbs.) 15 15 Bar (218 PSI) Fluorocarbon Seal SK10-3SV
Technical

C10-3S 20 20 Bar (290 PSI)


Cavity
Data

(See BC Section for more details)

LE17 Parker Hannifin Corporation


HVS and MSDE Divisions

You might also like