Review of Vibration Isolation Techniques and Design Standards in

Semiconductor Manufacturing

Edjhen A. Villaruel

Introduction

The semiconductor manufacturing sector is pivotal to contemporary technology,

necessitating precise production methods where vibration management is crucial. Vibration

isolation techniques are vital for reducing disturbances that could jeopardize the integrity of

semiconductor wafers, ultimately affecting yield and operational performance. Structural

engineering plays a key role in designing frameworks that can support heavy machinery and

efficiently absorb vibrations from outside sources. By employing advanced vibration isolation

techniques and adhering to rigorous design standards, stakeholders can enhance the operational

stability and reliability of semiconductor manufacturing environments, ensuring the quality and

efficiency required to keep pace with a rapidly advancing technological landscape.

Fundamentals of Vibration

Within structural engineering, engineers focus on understanding the sources, transmission

modes, and mitigation strategies for vibrations. They are responsible for ensuring that buildings

and facilities function effectively while being resilient to varying influences. Manufacturing

plants may encounter vibrations from numerous machines, HVAC systems, or other operational

equipment. Thus, structural engineers must identify and evaluate these sources to create

foundations and structures that mitigate or isolate their impacts. This typically requires the use of

vibration-dampening materials or technologies alongside enhancements to the structural design of

elements like floors, beams, and columns.

1
Investigating vibrations in industrial settings through analytical models is essential to

enhance equipment reliability, reduce maintenance expenses, and boost overall production

efficiency. Engineers utilize precise mathematical models to forecast and examine vibration

patterns, identify potential issues, and implement preventative measures. This proactive strategy

not only optimizes equipment performance and minimizes downtime but also ensures product

quality, thus increasing process reliability.

Vibration Isolation Techniques

The technique most commonly used in semiconductor production facilities is passive

vibration isolation. It involves the use of mechanical isolation components that naturally lessen

vibrations by absorbing and dispersing vibrational energy through materials or structures. These

components often include metallic vibration dampers (like rubber or spring-supported platforms),

air springs, and elastomeric supports. These isolators work by providing a flexible foundation that

isolates sensitive electronics from external vibration sources. Ensuring that the isolators'

resonance frequency does not match the operating frequencies of the equipment being isolated is

the main challenge with passive isolation. Furthermore, passive isolation tends to be efficient for

low-frequency vibrations (0-20 Hz), which frequently cause the most disturbances in

semiconductor production, particularly in processes such as photolithography that demand sub-

micron accuracy (Liu et al., 2012; Mahajan et al., 2016).

Sensors, actuators, and control systems are used in Active Vibration Isolation to instantly

and dynamically alter and neutralize vibrations. Although these systems are more expensive and

complex, they offer higher levels of precision and adaptability. By creating forces that resist the

detected vibrations, active isolation systems reduce vibrations using piezoelectric actuators,

electromagnetic actuators, or hydraulic mechanisms. These devices are frequently used in

situations where passive isolation is insufficient or if the vibrations' strength and rate are

constantly changing. Since even small vibrations can reduce image clarity and operational

2
precision, active vibration isolation has been shown to significantly improve the performance of

sensitive semiconductor devices, such as scanning electron microscopes (SEMs) and

photolithography equipment (Huang et al., 2018).

The advantages of passive and active techniques are combined in hybrid isolation

systems. In these systems, active systems are employed to correct and regulate any residual

vibrations that may still exist, while passive isolators are used for wide-ranging vibration isolation.

In environments with a wide and fluctuating vibration spectrum, such as semiconductor

production facilities, where low- and high-frequency disturbances occur simultaneously, hybrid

systems are particularly advantageous. In order to achieve maximum efficiency at various

frequencies, vibration isolation tables used with photolithography equipment usually combine air

springs (for wide isolation) and active actuators (for precise adjustments) (Kang et al., 2015).

Low-frequency isolation, which specifically addresses the problems caused by low-frequency

vibrations that are especially harmful to semiconductor processes, is another promising technique

in the field. To do this, specific flooring systems or foundations designed to isolate low-frequency

seismic vibrations from the surrounding environment must be used. Techniques including seismic

isolators, vibration-damping floor pads, and reinforced concrete foundations have been

successfully used in semiconductor factories situated in areas susceptible to low-frequency

disturbances (Wu et al., 2013). To lessen the impact of ground vibrations and ensure that the

sensitive equipment operates within predetermined tolerances, these customized flooring systems

work in tandem with other vibration isolation technologies.

Materials such as viscoelastic polymers, elastomers, and composites are used to absorb

vibrations at frequencies higher than 100 Hz to achieve high-frequency isolation. These are

particularly useful for isolating vibrations produced by machinery that regularly generates high-

frequency noise, including pumps, compressors, or air handling systems. To reduce the amount of

high-frequency noise that enters crucial parts of the fab, these materials are purposefully placed

inside the vibration isolation mounts or surrounding equipment (Liu et al., 2017). The design of

3
the supporting infrastructure, including the walls, floors, and foundations, must also be

considered to provide appropriate vibration isolation. Structural features that are designed to

isolate sensitive equipment from the building framework, like sturdy foundations or floating

floors, might be very important. Many times, whole buildings or cleanrooms are designed with

vibration isolation in mind, using unique floors, walls, and ceilings to reduce vibrations entering

the workstation (Kim et al., 2014).

Design Consideration

Structural engineering is vital in crafting vibration isolation systems for semiconductor

manufacturing facilities, ensuring that the building's foundation and internal components can

effectively reduce vibrations. The primary objective is to diminish unwanted vibration

transmission from both internal sources (like HVAC systems) and external sources (such as

traffic or seismic events). Since these vibrations can hinder the performance of highly sensitive

semiconductor manufacturing processes and equipment, a thorough examination of structural

components is essential.

One of the first critical design considerations involves evaluating site-specific vibrations.

Engineers must conduct an exhaustive analysis of the surrounding environment to identify

potential vibration sources and assess their magnitude and frequency range. For example, in

seismic areas, low-frequency ground vibrations must be factored in, while urban settings may see

significant contributions from traffic and construction. This assessment aids in determining the

vibration sensitivity of particular machinery and informs the selection of appropriate isolation

methods. The foundation and flooring system design must also take into account the expected

vibration loads and types (whether high-frequency mechanical or low-frequency seismic) to

ensure that isolation methods are effectively tailored. Material selection for vibration isolation is

another significant factor, influenced by vibration frequency, load capacity, and longevity. While

viscoelastic materials are typically used for high-frequency vibration reduction, rubber, metal

4
composites, and elastomers are often selected for passive isolation in semiconductor

manufacturing. The choice of materials should find a balance between providing sufficient

isolation and maintaining long-term stability without degradation. It is vital to consider both

performance and cleanliness criteria (e.g., resistance to particle generation and low outgassing),

as the materials must suit cleanroom conditions, where contamination control is paramount.

Structural integrity of the isolation system is also crucial. The vibration isolation systems

must be integrated into the building's structural framework, necessitating careful coordination

between the isolation mechanisms and load-bearing elements. A common approach involves a

"floating floor" design, wherein the main floor is separated from the subfloor or foundation by an

isolating material layer, such as air springs or cushioning pads. The foundation must be

adequately designed to prevent excessive movement or resonance, which is essential for effective

vibration decoupling.

Reliability assessment of these systems is essential to ensure they can withstand

prolonged operational stresses without compromising effectiveness. Additionally, dynamic load

analysis is critical when designing vibration isolation systems, as semiconductor tools and

machinery are generally highly sensitive and precise. Structural engineers must calculate both

dynamic loads from machinery operations and static loads, which include the weight of the

structure and equipment, as well as transient forces from machinery startup or external

disturbances. The isolation system must manage these dynamic loads without causing resonance

or exceeding the limitations of the isolation components, requiring a comprehensive

understanding of the vibration frequencies specific to the equipment and their interaction with the

building structure.

The architectural design of the building significantly influences vibration isolation system

design. The floor layout should minimize the overall vibration transmission throughout the

building, typically achieved by situating delicate equipment in isolated areas and encasing these

zones with structural barriers, such as isolation pads or vibration-dampened flooring. It may also

5
be necessary to construct walls, barriers, or partitions that resist vibrations to prevent transmission

between different areas of the facility. Additionally, vibration isolation considerations should

extend to HVAC and electrical systems to prevent mechanical systems from generating high-

frequency vibrations that could damage sensitive industrial equipment. Moreover, proper

integration of vibration isolation devices into cleanroom designs is critical to avoid interfering

with essential environmental factors, such as temperature control and airflow, which are vital to

the manufacturing process.

Lastly, the design phase should account for ongoing maintenance and monitoring.

Vibration isolation devices may degrade over time, particularly in environments subjected to

heavy loads or frequent operational cycles. Therefore, creating systems that facilitate easy

monitoring and management is crucial for ensuring continued effectiveness. This involves

designing isolation components that can be replaced or repaired as needed and incorporating

monitoring systems that track performance metrics, such as vibration frequency and displacement.

Engineers might also explore embedding sensors in flooring or foundation systems to

continuously monitor vibration levels, allowing for timely adjustments or repairs before

vibrations exceed acceptable limits for sensitive equipment.

Design Standard and Guidelines

The principles of structural engineering underpin the standards for vibration control in

semiconductor manufacturing, which are essential for creating stable environments that support

sensitive processes like wafer etching and lithography. Structural engineers are responsible for

designing buildings that effectively isolate and mitigate vibrations to maintain structural integrity

and meet operational requirements.

A crucial aspect of structural engineering for vibration reduction involves enhancing the

stiffness of flooring and supports. This is achieved by elevating the natural frequency of the

structure above the operational frequencies of potential vibration sources to prevent resonance,

6
which amplifies vibrations. This may involve using more robust materials and designs, such as

reinforced concrete or steel structures. Reinforced floor slabs are employed to support equipment

with stringent vibration limitations, ensuring that even minor external vibrations are mitigated

before affecting sensitive zones. Equipment requiring high levels of vibration isolation, like

photolithography systems, is often placed on dedicated bases that utilize spring-mounted supports

or elastomeric bearings to isolate vibrations from adjacent structural components. Subfloor

isolation strategies are implemented to prevent vibrations from construction activities, such as

HVAC operations or nearby vehicle movement, from transmitting through the building. Utilizing

materials with superior damping characteristics in structural frameworks helps absorb and

disperse vibrational energy, with flooring systems and equipment mounts incorporating

composite materials, elastomeric pads, and viscoelastic layers. These materials are particularly

effective in addressing broadband and tonal vibrations generated by mechanical systems like

pumps and fans.

Structural engineering solutions must also accommodate modifications throughout the

facility's lifespan, such as equipment upgrades or operational changes. Standards like ISO 14644

emphasize the importance of ongoing monitoring and adaptable design approaches to ensure

compliance with vibration control requirements. This includes reinforcing aging structures or

integrating new isolation systems as necessary.

Emerging Trend

One of the primary trends in structural engineering is the development of advanced

materials to enhance vibration isolation and damping capabilities. Innovative materials, including

meta-materials and engineered composites designed for specific vibrational properties, are being

incorporated into equipment mounts and building structures to achieve greater levels of vibration

reduction. These materials effectively target specific frequencies, making them particularly useful

for minimizing vibrations that could disrupt sensitive semiconductor manufacturing equipment.

7
Recent research has focused on creating active vibration control systems to improve upon

traditional passive isolation methods utilizing springs or elastomers. These advanced devices

deploy sensors and actuators that detect vibrations in real-time and generate counteracting forces

to mitigate their effects. Active systems are increasingly utilized in semiconductor manufacturing

to manage high-frequency vibrations or unexpected disturbances that passive systems may not

fully address. They are especially beneficial for high-precision equipment requiring stringent

vibration tolerances, such as extreme ultraviolet (EUV) lithography machines and scanning

electron microscopes. The integration of these technologies is viewed as a potential development

for highly sensitive semiconductor manufacturing environments.

Looking ahead, the future of vibration control in semiconductor production will likely

involve a more integrated approach that combines cognitive technologies and structural systems.

The implementation of IoT (Internet of Things) devices, integrated sensors, and real-time data

processing tools is revolutionizing vibration monitoring and control in these facilities. Structural

engineers are incorporating sensors into building components to continuously monitor vibration

levels and adjust systems as necessary. This enables predictive maintenance and more adaptable

responses to changes in operational conditions. For instance, if a structure experiences

unexpected vibrations due to new machinery or external factors, the system can detect and

respond before these disturbances adversely affect sensitive processes.

As semiconductor manufacturing continues to evolve, the demand for precise vibration

control systems is becoming increasingly critical, especially with the rise of sophisticated

technologies like quantum computing and AI chip production. Structural engineers are tasked

with developing tailored solutions that meet the specific requirements of advanced semiconductor

equipment. For instance, specialized vibration isolation systems are being designed to

accommodate the exact operational needs of EUV lithography machines, which necessitate

exceptionally stable bases. As the demand for precision and miniaturization in semiconductor

devices grows, this trend is expected to persist.

8
As the global semiconductor industry expands, uniform vibration control standards are

becoming increasingly essential. Structural engineers are collaborating with industry experts to

establish universal standards that address the unique challenges of vibration control within

semiconductor manufacturing facilities. These guidelines will enhance the performance and

integration of global semiconductor production networks by ensuring that vibration isolation

systems function reliably across diverse locations and facilities.

Findings and Conclusion

The exploration of vibration isolation techniques in semiconductor

manufacturing underscores the vital role of structural engineering in maintaining the precision

and stability essential for sensitive equipment. Key strategies include the utilization of advanced

materials that effectively diminish vibrations, such as elastomers, meta-materials, and composites,

as well as the incorporation of active vibration control systems that enable rapid adjustments.

Structural solutions like reinforced flooring, separate foundations, and damping materials

contribute significantly to effective vibration reduction.

Furthermore, the increasing importance of smart sensors and IoT technology is evident,

as they provide predictive maintenance and real-time monitoring to proactively mitigate potential

vibration concerns. Emerging trends emphasize sustainability in design and the customization of

vibration isolation for highly sensitive machinery, such as EUV lithography systems, ensuring

that future semiconductor manufacturing facilities consistently meet exacting precision standards.

In conclusion, achieving effective vibration isolation in semiconductor manufacturing

requires a cohesive approach that integrates intelligent technologies, innovative materials, and

robust structural engineering. The future of vibration control will focus on developing tailored,

adaptable solutions that address the unique challenges posed by cutting-edge semiconductor

equipment. As the industry advances toward more precise and efficient manufacturing methods,

structural engineers will play a pivotal role in refining vibration control strategies, thereby

9
ensuring the stability and accuracy necessary to propel semiconductor production forward. By

leveraging innovative technologies and sustainable practices, the semiconductor industry can

ensure that vibration control systems evolve in tandem with the demands of next-generation

manufacturing.

References

Al-Hunaity, S. A., & Far, H. (2024). Vibration performance of cold-formed steel and plywood

composite floors – Experimental studies. Journal of Constructional Steel Research, 219,

108793. https://doi.org/10.1016/j.jcsr.2024.108793

Bayat, E., Tubino, F., & DICCA, University of Genoa. (2024). Human-induced vibrations of

floors: A probabilistic approach. In Engineering Structures (Vol. 300, p. 117198)

[Journal-article]. https://doi.org/10.1016/j.engstruct.2023.117198

Beards, C. E., Imperial College of Science, Technology and Medicine, Hodder Headline Group,

Halsted Press, JohnWiley &Sons Inc., Arnold, British Library, Library of Congress,

Poole Typesetting (Wessex) Ltd, & J W Arrowsmith Ltd. (1996). Structural Vibration:

Analysis and Damping. Arnold.

Becker, R. (1980). Simplified Investigation of Floors under Foot Traffic. Journal of the

Structural Division, 106(11), 2221–2234. https://doi.org/10.1061/jsdeag.0005572

Bin, P., & Harvey, P. (2022). A dual-mode floor isolation system to achieve vibration isolation

and absorption: Experiments and theory. Journal of Sound and Vibration, 525, 116757.

https://doi.org/10.1016/j.jsv.2022.116757

Brownjohn, J., & Middleton, C. (2007). Procedures for vibration serviceability assessment of

high-frequency floors. Engineering Structures, 30(6), 1548–1559.

https://doi.org/10.1016/j.engstruct.2007.10.006

10
Cao, L., Li, J., Chen, Y. F., & Huang, S. (2023). Measurement and application of walking models

for evaluating floor vibration. Structures, 50, 561–575.

https://doi.org/10.1016/j.istruc.2023.02.073

Chen, W.F., & Lui, E.M. (Eds.). (2005). Handbook of Structural Engineering (2nd ed.). CRC

Press. https://doi.org/10.1201/9781420039931

Chu, T., Nguyen, T., Yoo, H., & Wang, J. (2024). A review of vibration analysis and its

applications. Heliyon, e26282. https://doi.org/10.1016/j.heliyon.2024.e26282

Drira, S., a,b, Smith, I. F. C., a,b, & The Authors. (2022). A framework for occupancy detection

and tracking using floor-vibration signals. In Mechanical Systems and Signal Processing

(Vol. 168, p. 108472). https://doi.org/10.1016/j.ymssp.2021.108472

Friehe, M., Heinemeyer, C., & Feldmann, M. (2017). Design of highly sensitive floors for

human induced vibrations. Procedia Engineering, 199, 2796–2801.

https://doi.org/10.1016/j.proeng.2017.09.549

Fu, Q., & Tan, K. (2019). Numerical study on steel-concrete composite floor systems under

corner column removal scenario. Structures, 21, 33–44.

https://doi.org/10.1016/j.istruc.2019.06.003

Gendreau, M., Colin Gordon & Associates, & Amick, H. (2005). Maturation of the

Vibration Environment in Advanced Technology Facilities. In Journal of the IEST

(Vol. 48, Issue 1, pp. 83–84).

Guo, Q., Zhou, J., Li, L., Xu, M., & Tang, G. (2024). Design and experimental study of a

hybrid Micro-Vibration isolation system based on a strain sensor for High-

Precision space payloads. Sensors, 24(5), 1649. https://doi.org/10.3390/s24051649

Huang, Y., Zhang, L., & Zhao, X. (2018). Active vibration isolation for high-precision

semiconductor equipment. Journal of Vibration and Control, 24(3), 574-584.

Irwin, A. W. (1978). Human response to dynamic motion of structures. Structural Engineer, 56(9).

11
ISO. (2007). Bases for design of structures — Serviceability of buildings and walkways against

vibrations. In ISO, ISO. https://standards.iteh.ai/catalog/standards/sist/94ef0a6e-1fc0-

4946-9dbd-44da51a7d8b0/iso-10137-2007

Kang, Y., Cho, H., & Kim, H. (2015). Hybrid vibration isolation for semiconductor

manufacturing tools. Journal of Semiconductor Technology and Science, 15(4), 317-323.

Kim, M., Kim, Y., & Park, S. (2014). Design of vibration-isolated cleanrooms for semiconductor

fabs. Cleanroom Technology, 15(2), 88-94.

Kim, S., Kim, D. W., & Kwak, M. K. (2023). Design and Implementation of an Active Vibration

Control Algorithm Using Servo Actuator Control Installed in Series with a Spring-

Damper. Applied Sciences, 13(5), 3349. https://doi.org/10.3390/app13053349

Liu, X., Chen, H., & Xu, Z. (2012). Design of vibration isolation systems for semiconductor

fabrication environments. Journal of Manufacturing Science and Engineering, 134(6),

061012.

Liu, Y., Wang, J., & Shen, Q. (2017). High-frequency vibration control for semiconductor

equipment. International Journal of Precision Engineering and Manufacturing, 18(8),

1175-1183. https://doi.org/10.1007/s12541-017-0133-0

Lv, Q., Lu, Y., & Liu, Y. (2021). Vibration serviceability of suspended floor: Full-scale

experimental study and assessment. Structures, 34, 1651–1664.

https://doi.org/10.1016/j.istruc.2021.08.120

Mahajan, A., Tiwari, R., & Deshpande, P. (2016). Vibration control techniques for semiconductor

manufacturing equipment. Precision Engineering, 47, 33-45.

Mohammed, A., Pavic, A., & Racic, V. (2018). Improved model for human induced

vibrations of high-frequency floors. Engineering Structures, 168, 950–966.

https://doi.org/10.1016/j.engstruct.2018.04.093

Ndukwe, A. I. & Federal University of Technology Owerri. (2024). Damping and

Vibration Control in Modern Manufacturing Materials Using Shape Memory Allory:

12
A Review. Academic Journal of Manufacturing Engineering, 12–13.

https://www.researchgate.net/publication/379505429

Salyards, K. A., Firman, R. J., III, & Bucknell University. (2009). Review of Generic and

Manufacturer Design Criteria for Vibration-Sensitive Equipment. In Proceedings

of the IMAC-XXVII [Conference-proceeding]. Society for Experimental

Mechanics Inc.

Wang, L., Gong, G., & Xia, J. (2024). Comparison of evaluations of human-induced floor

vibration based on different design guidelines. Structures, 68, 107114.

https://doi.org/10.1016/j.istruc.2024.107114

Wu, W., Chang, Y., & Liang, C. (2013). Vibration mitigation techniques in semiconductor

facilities: A review. Applied Mechanics and Materials, 465-466, 1603-1609.

Zhou, G., & Chen, J. (2022). Floor live load survey by forced vibration test using human-induced

excitation. Engineering Structures, 272, 114961.

https://doi.org/10.1016/j.engstruct.2022.114961

Vibration Control Systems Market. (2022, October 10).

https://www.futuremarketinsights.com/reports/vibration-control-systems-market

Structural Engineering’s Importance in Semiconductor Fab Design. (n.d.).

https://www.structuremag.org/article/structural-engineerings-importance-in-

semiconductor-fab-design/

13

You might also like