FirmwareUpgradeInstructionsRx3iCPEs v1 - 4
FirmwareUpgradeInstructionsRx3iCPEs v1 - 4
Version 1.4
Instructions for Firmware Upgrade
Once the structure on the USB flash drive matches the example below, please proceed to Section 2.
Page 2 of 5
Instructions for Firmware Upgrade
4. Insert the prepared USB flash drive in the port labeled USB-A RDSD. Press and release the START
button. The RDSD LED will blink green while the image is being copied to the CPU (15-20 seconds).
When the copy has completed, the RDSD LED will stop blinking, and turn off. NOTE: It is imperative
that power not be disrupted and the USB flash drive not be removed while the image copy is in
progress… irreparable damage could occur to the CPU.
COM 1
ETHERNET
USB-A RDSD !
COM 2
Page 3 of 5
Instructions for Firmware Upgrade
Common Failures
1. CPU will not read USB flash drive.
Symptoms: Includes indication update succeeded but the update did not take place, or indication
update fails (red LED).
Correction: Though the RX3i CPU modules with USB capability are compatible with Version 2.0 USB
flash drives, not all drives are made the same. If the CPU has trouble reading the USB flash drive, try
another Version 2.0 USB flash drive (different model and/or different manufacturer).
Page 4 of 5
Instructions for Firmware Upgrade
Technical Support
Americas
Phone: 1-888-565-4155
Europe
Phone: +800-4444-8001
Asia
Phone: +86-400-842-8599
Note: If the product is purchased through an Authorized Channel Partner, please contact the seller
directly for any support.
Emerson reserves the right to modify or improve the designs or specifications of the products mentioned
in this manual at any time without notice. Emerson does not assume responsibility for the selection, use,
or maintenance of any product. Responsibility for proper selection, use, and maintenance of any
Emerson product remains solely with the purchaser.