0% found this document useful (0 votes)
24 views2 pages

CoolAutomation CoolMaster CoreModule v1.0 Help

The document provides information about the CoolAutomation CoolMaster CoreModule v1.0, designed for HVAC systems compatible with generation 2 and 3 Crestron controllers. It includes details on setup requirements, control commands for HVAC units, polling parameters, and feedback signals. The document also outlines testing conditions and revision history for the software version.

Uploaded by

olegdax
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views2 pages

CoolAutomation CoolMaster CoreModule v1.0 Help

The document provides information about the CoolAutomation CoolMaster CoreModule v1.0, designed for HVAC systems compatible with generation 2 and 3 Crestron controllers. It includes details on setup requirements, control commands for HVAC units, polling parameters, and feedback signals. The document also outlines testing conditions and revision history for the software version.

Uploaded by

olegdax
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Partner: Cool Automation

Model: 1000D or Compatible


Device Type: HVAC

GENERAL INFORMATION
SIMPLWINDOWS NAME: CoolAutomation CoolMaster CoreModule v1.0.umc

CATEGORY: HVAC

VERSION: 1

SUMMARY:

GENERAL NOTES: Suits generation 2 and 3 Crestron controllers

C2I-COM, ST-COM, C2-COM-* or CNX-COM2, any Crestron controller with 2-way


CRESTRON HARDWARE REQUIRED:
RS232 port

RS232
Baud:9600
SETUP OF CRESTRON HARDWARE: Parity: None
Data Bits: 8
Stop Bits: 1

VENDOR FIRMWARE: 03/03/13

VENDOR SETUP:

CABLE DIAGRAM:
Partner: Cool Automation
Model: 1000D or Compatible
Device Type: HVAC

CONTROL:
HVAC_All_Units_ON_Press D Pulse to turn ALL units ON

HVAC_All_Units_OFF_Press D Pulse to turn ALL units OFF

HVAC_Celsius/Fahrenheit_Toggle_Press D Pulse to toggle between Celsius and Fahrenheit states.

Remain high to poll all the units every Poll TIME.


Polling the system doesn't affects other commands. While a command should be
Poll_Enable D
sent the polling process will stop immediately.
Poll TIME can be set in the parameters field.

fromModules S Serial data signal to be routed from thermostat module.

fromCoolMaster S Serial data signal to be routed from a 2 way com port.

PARAMETERS:
TIME parameter representing the poll time (e.x.: 5s will cause the program to
Poll TIME T
send poll command every 5 seconds.).

FEEDBACK:
HVAC_Fahrenheit_fbck D Latches high to indicate that degrees are in Fahrenheit format.

toModules S Serial data signal to be routed to thermostat module.

toCoolMaster S Serial data signal to be routed to a 2 way com port.

TESTING:
OPS USED FOR TESTING: Windows 8

SIMPL WINDOWS USED FOR TESTING: 4.001.10

DEVICE DB USED FOR TESTING: 47.05.005.00

CRES DB USED FOR TESTING: 37.00.013.00

SYMBOL LIBRARY USED FOR TESTING: 850

SAMPLE PROGRAM: CoolAutomation CoolMaster v1.0 Demo MC3

REVISION HISTORY: v1.0 – Initial Release