Operating Manual SPC 10KW USA+EU

The document is an operating manual for the Shore Power Converter SPC 10 kW, detailing safety instructions, startup procedures, panel menu navigation, and connection guidelines. It emphasizes the importance of qualified operators for installation and warns against potential hazards. Additionally, it includes information on protections, quality assurance, warranty, and a declaration of conformity with EU standards.

Uploaded by

jlope0009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views10 pages

Operating Manual SPC 10KW USA+EU

The document is an operating manual for the Shore Power Converter SPC 10 kW, detailing safety instructions, startup procedures, panel menu navigation, and connection guidelines. It emphasizes the importance of qualified operators for installation and warns against potential hazards. Additionally, it includes information on protections, quality assurance, warranty, and a declaration of conformity with EU standards.

Uploaded by

jlope0009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

1

Shore Power Converter SPC 10 kW


Frequency Converter

Operating manual

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
2

Index

PAGE
1. Warnings & Safety Instructions “ 3
2. Front panel “ 4
2.1. Keyswitch “ 4

2.2. LED signals “ 4


2.3. Control push buttons “ 4
3. STARTUP “ 4
3.1. Startup “ 4
3.2. Ignition “ 5
3.3. Removing the Key “ 5
4. Panel menu “ 5
4.1. Measurements “ 5
4.2. Alarm “ 6
4.3. Output setup “ 6
5. Connections “ 6

6. Interface “ 7

7. Protections “ 7

8. Reset after over temperature or overload protection “ 7


9. Operating conditions and anomalies “ 8
9.1. Problem and anomalies according to LED and LCD “ 8
9.2 Problem and anomalies that cannot be indicated by LED and LCD “ 8
10. Quality assurance “ 8

11. Warranty “ 8
12. Declariation of Conformity “ 9

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
3

IMPORTANT SAFETY INSTRUCTIONS

READ CAREFULLY THE HANDBOOK BEFORE USING THE EQUIPMENT

USE AND INSTALLATION OF THIS EQUIPMENT ARE RESERVED TO QUALIFIED


OPERATORS

WARNING:
DANGEROUS VOLTAGES ARE PRESENT IN THE EQUIPMENT.
DISCONNECT THE STABILIZER BEFORE OPENING THE DOORS.
INSTALLATION MUST BE PROVIDED BY A QUALIFIED OPERATOR.
USE ONLY ISOLATED AND PROFESSIONAL TOOLS.

1. WARNINGS

The equipment cannot be used in zones that are


potentially flammable or explosive.

The equipment should be used only when the boat engine is off.
Disconnect AC shore power before opening the equipment.

Before installation make sure that adequate system of


smoke or gas detector are provided

The equipment cannot be used in parallel with


co-generation system.

Follow all the safety instructions in this manual.


Improper use could fully damage the equipment.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
4

Install the Converter away from any heat. Proper ventilation around the unit is very important: allow at
least 20 cm/ 8 inch between the front and the rear part of the unit to ensure suf cient air ow to the
cooling fan. During normal operation the equipment may reach high temperatures, install the Converter
in an area where people will not get in contact with it. An appropriate periodic cleaning and
maintenance program is recommended to keep the equipment in perfect condition. If the equipment is
installed in a particularly dusty environment, increase the cleaning and maintenance program, making
sure that the ventilation system is working properly.
2. Front panel

Keyswitch, LCD display, led status signals and control pushbuttons are located on the front panel

2.1. KEYSWITCH

The keyswitch allows to start the converter. It will take 70 seconds. If the key is set in the [ON] position,
at the end of the initialization, the SPC will supply power. If the key is turned in [OFF] position, at the end
of the initialization the converter is ready to start immediately, as soon as the key is turned in [ON]
position.

2.2. LED SIGNAL

[Ready] Green Led ight: the Converter is ready to start.


[On] Green Led Light: the Converter is operational.

[Fault] Red Led Light: the LED light appears if there is a malfunction on the converter.
We recommend you to call for assistance.

2.3. CONTROL PUSH BUTTONS

The menu navigation commands is used to control the equipment, display messages/electrical power
feedbacks, on the LCD panel. Please refer to sections 3 and 4 of this manual for detailed information.

3. STARTUP
3.1. Startup

When the converter is powered up it takes 70 seconds to be ready to operate. A welcome message will
appear. A countdown appears showing the remaining time before the inverter is ready to operate.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
fi
fl
5

During the rst start-up, the system will verify its status. It will take 70 seconds to appear the [ON] green
led. During this phase, the equipment will not accept any command.

At the end of this process, the Converter will be ready for operation. A message will show the status of
the key and the inverter. At the end of the process a green light appears and the panel shows: “key OFF
and inverter OFF.”

3.2. IGNITION

Turning the key from OFF position to ON position the converter turns on and the panel shows: “Key
on, inverter on.”

AUTO-RESTART
If a voltage drops or a blackout occurs the converter will shut off and it will restart automatically when
the power restores. The process will take 70 seconds and the previously settings will be maintained.

3.3 REMOVING THE KEY

When the installation of the converter is done, remove the key leaving it on the ON position. This will
allow your converter to always be in AUTO-RESTART mode.

4. PANEL MENU

Pressing the SET push button you will see three types of menu. The rst shows the electrical measurements,
the second displays the alarms and the third one allows to increase or decrease the output voltage +/- 10
volts. We strongly suggest not to manipulate this setting in order to not compromise the converter
functionality.

To change menu, press SET. To scroll through the pages in the menu press the Up and Down push
buttons.

4.1. MEASUREMENTS MENU

This menu shows the value of the electrical measurements:

Page 1: Input Voltage, Input Current, Output Power.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
fi
fi
6

Page 2: Output Voltage, Output Current, Power

Page 3: Output peak Voltage, Output peak Power, Internal temperature.

Page 4: Output frequency – Measure output mode

The last page of the menu allows you to select the measurement display mode. By keeping pressed for 15
seconds the up button, you can change the frequency mode between 50 and 60 Hz.

4.2 ALARM MENU

This menu shows the alarm status. If there are no alarms the page will be blank.

When an alarm occurs, the inverter turns off; the green LED goes off and the red LED lights up to alert the
user.
To display the alarm type enter alarm menu

4.3 OUTPUT SETUP MENU

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
7

Entering this menu the user can set output voltage by selecting the right and and left pushbuttons.
To switch the frequency from 50 to 60Hz hold down the [UP] button for 15 seconds. To switch the frequency
from 60 to 50 Hz hold down the [UP] button for 15 seconds. To con rm the selected value press the "SET"
button.
The selected value will be stored automatically when you exit from the menu.

5. CONNECTIONS

The power system is composed of one cabinet. The converter is provided with the ANG AUTO-RANGING
Input Voltage System. It will automatically accept single phase voltage ranging from 190 to 260 volts. The
connection to the terminal block to the power supply, is located on the side of the cabinet. The converter
automatically con gure itself based to the input line voltage.

It can be powered with ONLY 1 SINGLE PHASE power cord.

Positioned on the side of the cabinets, where the DANGER sticker is attached, there is a removable panel,
that give you access at all the terminal block connections.

INPUT LINE

SINGLE PHASE CONNECTION


L1 L2 + GND

OUTPUT LINE

EUROPEAN OUTPUT: U2 V2 + GND (0-230V)

USA OUTPUT: U2 V2 +NO +GND


(120-240V)

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
fi
fi
8

6. INTERFACE

The converter can be optionally provided of a RS232 interface port that used to remote diagnostics via
optional radio transmitter.

7. PROTECTIONS
The product is electronically protected against overload, short-circuit and over temperature as to avoid
irreversible faults to the product. Should the internal temperature be higher than 55°C (131°F) or should
the current be higher than 105% of the maximum rated current for more than 6 (six) seconds, the
converter will stop itself.
Subsequently, the inverter will automatically restart. If this procedure is repeated 3 times in a time less
than 2 minutes the converter permanently locks.
To restart it it will be necessary to use the key.

8. RESET AFTER OVER TEMPERATURE OR OVER LOAD PROTECTION LOCK

In order to reset the converter switch it off and on again. After an overtemperature protection, the
converter can be reset only when the internal temperature achieves 45°C (113°F).
An overload can only be solved by lowering it. In case of overload we recommend to check the boat’s
power demand.

9. OPERATING CONDITIONS AND ANOMALIES

9.1. Issues related to led and LCD.

Front panel leds and LCD display will alert the operator in case of faults.
Most issueswill switch “Fault” led on and the LCD display will show a description of the problem.

9.2. Problems that cannot be shown by LED and LCD display

Some problems cannot be signalized on the front panel:


1. Faulty front panel
2. Fault on recti er (the converter cannot be supplied)
3. Fault of sinusoidal generator on the board.
4. Fault of isolation transformer.

10. QUALITY ASSURANCE

The entire production cycle of our equipment is subject to surveillance regarding quality assurance. The
quality assurance system complies with ISO9001-2008 standard.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
fi
9

11. WARRANTY

This product and all its components have been tested and accurately checked before exiting
production and is warranted for a period of 24 months (2 year) after the purchase date.
(Purchase date is the one that appears on the invoice).

Please refer to the warranty declaration provided on our website.

Notes:

• A.N.G. USA Inc. is responsible only for the performance of the equipment.
• Any other factor within the yacht that might cause the equipment not to perform ef ciently
isn’t to be considered our responsibility.
• A.N.G. USA Inc. guarantees all systems designed by us.
• All main replacements are always available in our head quarter in Fort Lauderdale and in
Italy.
• Prompt assistance and technical support are always guaranteed.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM
fi
10

Declaration of Conformity
(in conformity with UNI CEI EN ISO/IEC 17050-1:2005 and UNI CEI EN ISO/IEC 17050-2:2005
standards)
We

A.N.G. USA INC.


Fort Lauderdale , FL

Hereby declare that the product below conforms to the relevant requirements of the
appropriate EU directive.

- Name: Shore Power Converter


- Type: SPC 10 kW
- Power: 10 kW
- 1 phase Input Voltage: 190/260 Vac
- Input Frequency: 45|440
- Output Voltage: 0/230 or 120/240 +N +G Vac +/- 5%
- Output form Single Phase
- Output Frequency: 50 or 60 Hz

Applicable UE Directives:

- 2006/95/CE (EU Directive on Electrical equipment designed for use within certain voltage
limits);
- 2004/108/CE (EU Directive on Electromagnetic Compatibility).

Harmonized Standards:

- CEI EN 55022:2006 Information technology equipment. Radio disturbance characteristics.


Limits and methods of measurement.;
- CEI EN 61000-4-2/A2:2001 Electromagnetic compatibility (EMC). Part 4: Testing and
measurement techniques. Section 2: Electrostatic discharge immunity test.
- CEI EN 62040-1-1:2003 Uninterruptible power systems (UPS). Part 1-1: General and
safety requirements .
- CEI EN 62040-1-2:2003 Uninterruptible power systems (UPS). Part 1-2: General and safety
requirements.

A.N.G. USA INC.

HEADQUARTERS: 3200 S. ANDREWS AVE, SUITE 207 FORT LAUDERDALE, FL 33316 +1 (954) 368-3214
WORKSHOP: LMC - Lauderdale Marine Center 2001 SW 20TH STREET BLDG 2005 UNIT #2B FORT LAUDERDALE, FL 33315
MOBILE +1 (786) 447-5273 +1 (786) 444-5679 MOBILE ITALY +39 335 675 6169
[email protected] | ANGCONVERTERS.COM

You might also like