GS146 1
GS146 1
COLUMN INTERNALS
September 1995
Document Title
COLUMN INTERNALS
APPLICABILITY
Regional Applicability: International
This document covers general requirements for the design, fabrication, supply, testing and
installation of trays, packings and other column internals.
AMENDMENTS
Amd Date Page(s) Description
___________________________________________________________________
Section Page
1. INTRODUCTION................................................................................................... 1
1.1 Scope 1
1.2 Application of this Specification........................................................................... 1
1.3 Quality Assurance................................................................................................ 1
2. COLUMN TRAYS.................................................................................................. 1
2.1 General Arrangement and Size Requirements....................................................... 1
2.2 Fractionator Tray Design Details ......................................................................... 2
2.3 Materials and Thickness....................................................................................... 4
2.4 Structural Details................................................................................................. 5
2.5 Clamping and Bolting Arrangements.................................................................... 7
2.6 Seal Welding ....................................................................................................... 8
2.7 Manways and Access........................................................................................... 8
2.8 Gasketting ........................................................................................................... 8
2.9 Drainage.............................................................................................................. 9
2.10 Tolerances for Fabrication and Assembly .......................................................... 9
2.11 Vortex Breakers ............................................................................................. 10
2.12 Blanking on Sieve or Valve Trays ................................................................... 11
2.13 Tray Installation.............................................................................................. 11
2.14 Reflux Inlets ................................................................................................... 11
2.15 Feed Inlets ...................................................................................................... 12
3. PACKED COLUMNS........................................................................................... 13
3.1 General Arrangement......................................................................................... 13
3.2 Materials and Thickness..................................................................................... 13
3.3 Structural Detail ................................................................................................ 14
3.4 Packing.............................................................................................................. 14
3.5 Distributors - Gravity......................................................................................... 14
3.6 Distributors - Pressure ....................................................................................... 16
3.7 Ancillary Equipment .......................................................................................... 16
3.8 Tolerances ......................................................................................................... 17
GS 146-1
Column Internals PAGE i
5. VESSEL FEATURES ........................................................................................... 19
5.1 Internal Pipes..................................................................................................... 19
7. GUARANTEES..................................................................................................... 23
7.1 Mechanical ........................................................................................................ 23
7.2 Process .............................................................................................................. 24
APPENDIX A.............................................................................................................. 25
DEFINITIONS AND ABBREVIATIONS .............................................................. 25
APPENDIX B.............................................................................................................. 26
LIST OF REFERENCED DOCUMENTS............................................................... 26
GS 146-1
Column Internals PAGE ii
FOREWORD
The Introductory Volume contains a series of documents that provide an introduction to the
BP Group Recommended Practices and Specifications for Engineering (RPSEs). In
particular, the 'General Foreword' sets out the philosophy of the RPSEs. Other documents in
the Introductory Volume provide general guidance on using the RPSEs and background
information to Engineering Standards in BP. There are also recommendations for specific
definitions and requirements.
This document covers the major requirements of column internals appropriate to all BP
Businesses. Adherence to the procedures will ensure that the equipment is fit for purpose
whilst being cost effective
Application
This Guidance for Specification is intended to guide the purchaser in the use or creation of a
fit-for-purpose specification for enquiry or purchasing activity.
This document may refer to certain local, national or international regulations but the
responsibility to ensure compliance with legislation and any other statutory requirements lies
with the user. The user should adapt or supplement this document to ensure compliance for
the specific application.
This is a new BP Guidance for Specification which incorporates the substance of three
previous standards listed below:
BP (America) Refining Practice RP 7-2-2 (Fractionating Trays and Column Packing) - April
1992.
GS 146-1
Column Internals PAGE iii
Specification Ready for Application
A Specification (BP Spec 146-1) is available which may be suitable for enquiry or purchasing
without modification. It is derived from this BP Group Guidance for Specification by
retaining the technical body unaltered but omitting all commentary, omitting the data page and
inserting a modified Foreword.
Users are invited to feed back any comments and to detail experiences in the application of BP
RPSE's, to assist in the process of their continuous improvement.
For feedback and further information, please contact Standards Group, BP International or
the Custodian. See Quarterly Status List for contacts.
GS 146-1
Column Internals PAGE iv
1. INTRODUCTION
1.1 Scope
2. COLUMN TRAYS
2.1.1 For vessel of 840 mm (33") diameter and larger, tray panels,
downcomer sections and other tray components shall be of sectional
construction with sections removable through the vessel manways.
2.1.2 When a lifting beam is not available within the column, formed deck
sections shall have a maximum component weight of 50 kg and a
maximum length of 3000 mm (118").
2.1.3 When a lifting beam facility can be provided within a column, the length
and weight restrictions shall be governed by the ability to install
sectional components with the vessel in both the horizontal and
vertical.
The factors which govern the maximum weight/length are those necessary to ensure
safe working in a confined space.
GS 146-1
Column Internals PAGE 1
2.1.4 All tray components shall be designed to permit installation and
removal from the top side.
To design the internals to be installed from both sides is an expensive addition that
should be avoided unless absolutely necessary.
2.1.5 For vessels smaller than 840 mm diameter, cartridge tray assemblies
shall be provided and the vessel shall be flanged to permit installation
and withdrawal of the cartridge.
2.2.1 Sieve tray deck hole sizes should normally be selected between 4 mm
and 12 mm (5/32 - 1/2") diameter. Larger hole sizes shall be used
when the specification sheet specifies a fouling or corrosive service.
The ratio of the hole pitch to hole diameter shall be a minimum of 2.0.
Hole sizes larger than 25 mm (1") are more likely to weep, will restrict capacity
and cause a lower efficiency. They are not normally used.
2.2.2 Holes in sieve trays shall be formed with the punch exit on the
upperside of the tray. The manufacturer shall ensure through
fabrication and installation that this requirement is met for all deck
sections. Burrs on the sieve tray holes which would cause injury to
personnel, should be removed.
2.2.3 On sieve and valve trays the hole area shall be uniformly distributed in
the contacting area approximating equilateral triangular pitch. Hole
area per tray shall be within ±1% of the area specified.
2.2.4 In the closed position the valve shall not make full peripheral contact
with the tray deck.
Valve caps should be provided with an indentation which prevents such peripheral
contact and thus helps to prevent the valve from sticking closed.
2.2.5 Trays having more than two passes should be designed for equal
bubbling area per pass rather than equal flow path length per pass
subject to a minimum flowpath length of 450 mm (18").
In some multi pass designs this may cause problems with meeting minimum manway
dimensions. In such cases this should be discussed with the owner..
2.2.6 Trays with three or more passes shall be provided with vapour and
liquid balance ducts.
GS 146-1
Column Internals PAGE 2
These are tubes or ducts that connect the different vapour flow areas such that
pressures over the columns are equalised. The design should be discussed with BP.
2.2.7 Trays shall be designed to handle the vapour and liquid loads given on
the tray data sheets. Standard sieve tray performance data shall be
specified on an FRI basis.
It is recognised that proprietary trays using sieve decks will be designed according
to the manufacturer's own procedures and in this case the basis used for
calculating jet flood, entrainment, maximum sustainable loading and downcomer
backup shall be provided to the purchaser.
2.2.9 No sieve tray shall be designed for more than 80% (FRI basis) of jet
flood. Where sieve trays are used for vacuum service a maximum of
75% (FRI basis) of jet flood shall be used. No valve tray shall be
designed for more than 85% of jet flood. Where valve trays are used
for vacuum service a maximum of 77% of jet flood shall be used.
2.2.11 Where the design liquid loading on a straight segmental overflow weir
would be less than 0.9 litre/min. cm (0.6 USGPM/inch), 'picket fence'
type overflow weirs shall be provided. The minimum horizontal
distance between pickets shall be 50 mm (2"). The minimum vertical
height of picket above the weir shall be 150 mm (6"). The effective
weir rate at normal design flows shall be no less than 0.9 litre/min. cm
(0.6 USGPM/inch).
GS 146-1
Column Internals PAGE 3
2.2.12 If the method of weir attachment is such that gaps could be left
between the weir plate and the shell wall and/or between the weir plate
and the tray weir edge, slide plates shall be provided to seal these gaps.
2.2.13 For sloped or stepped downcomers, the bottom downcomer area must
not be less than 50% of the top downcomer area.
Thickness Thickness
Material mm nearest Material mm nearest
gauge gauge
Carbon steel 3 mm 10 Aluminium 2 mm 14
Stainless steel 2 mm 14 Nickel Alloys 2 mm 14
Monel 2 mm 14 Hastelloy 1.5 mm 16
Copper 2 mm 14 Zirconium 1.5 mm 16
2.3.2 The thickness of pressed alloy steel bubble caps and the riser thickness
shall not be less than 1.5 mm (0.059") and 2.0 mm (0.079")
respectively.
2.3.3 The thickness of proprietary valve units shall be set by the manufacturer
based on process requirements for the tray.
2.3.4 More than one weight of proprietary valves shall normally be achieved
by using thicker gauge material. The spot welding of a single weight
on a standard valve is an alternative but in cases where severe corrosion
is anticipated any weights shall be fully seal welded.
GS 146-1
Column Internals PAGE 4
2.3.6 Tray rings and downcomer bolting bars shall be in the same material as
the vessel. Tray rings and downcomer bolting bars for clad or lined
vessels shall be in the same material as the vessel cladding or lining,
subject to thermal stress limitations.
2.3.7 The dimensions of the tray support rings and downcomer bolting bars
shall be provided by the manufacturer.
Minimum excluding
Ring
Column ID Width thickness corrosion Maximum
allowance Thickness
mm mm Corrosion Other
resistant material
material
mm ins. mm ins. mm ins.
less than 900 40 6 0.24 6 0.24 15 0.59
901-1800 50 6 0.24 6 0.24 15 0.59
1801 - 3500 65 6 0.24 6 0.24 15 0.59
3501 - 6000 75 6 0.24 10 0.39 20 0.79
above 6001 100 6 0.24 10 0.39 20 0.79
2.3.9 Vessel Corrosion allowance shall apply to one side of all removable
support beams. Vessel Corrosion allowance does not have to be
applied to replaceable/removable tray parts.
2.3.10 For trays of corrosion resistant materials all bolting shall be of the same
material as the removable internals with which it is connected .
2.4.2 Certain larger diameter columns will require support beams that are
distinct members separate from the stiffened tray sections. These
GS 146-1
Column Internals PAGE 5
separate beams, whether rolled joists or channels, shall be securely
restrained against vertical and horizontal movement.
2.4.4 The design load shall include the weight of the internal element (with its
corrosion allowance) plus the following uniform downward loads at
design temperatures.
(c) Draw-off pans. The greater of 6865 N/m2 (700 kg/m2, 143 psi)
or a head of water to the top of the pan.
(d) Total draw-off trays. The greater of 6865 N/m2 (700 kg/m2,
143 psi) or a head of water to the top of the vapour riser or the
overflow weir.
(e) Baffle tray with a weir. The greater of 6865 N/m2 (700 kg/m2,
143 psi) on the projected area or the weight of water 50 mm
(2") over the weir height.
2.4.6 Structural shapes or clips shall be provided along the bottom edge of
the downcomer to ensure proper clearance between the bottom of the
downcomer and the tray deck. The design and installation of these
shapes or clips shall be such as to not interfere with the liquid flow
GS 146-1
Column Internals PAGE 6
exiting from under the downcomer. These clips may also be designed
to satisfy 2.4.5.
2.4.7 Adjustable weirs are not acceptable unless specifically required by the
project.
The specification of adjustable weirs is now an uncommon practice due to the ease
with which these can be incorrectly installed or otherwise maladjusted during
operations. The levelness of the tray therefore depends on the levelness of the tray
support ring and this requires an appropriate check.
2.4.8 Tray support rings shall be welded to the wall of the vessel to provide a
flat support for the assembled tray sections. The upper surface of the
tray support ring shall conform to the stated tray elevation. The ring
shall be level to within the tolerances given in 2.10.4.
2.5.2 Where carbon steel decks are specified, the non-threaded components
of clamping assemblies may be fabricated from carbon steel. Threaded
components shall be compatible with the process requirements and the
bolting material shall be AISI 304 stainless steel as a minimum.
2.5.3 Where the decks are specified in stainless steel, the clamp assemblies
shall be fabricated from the same material.
2.5.4 The maximum pitch between clamps shall be 180 mm (7") in the tray
active area and 100 mm (4") on the downcomer bolting bars and,
where used, on the downcomer floor. Each separate tray and
downcomer section shall have a clamp located as close to each corner
as possible.
2.5.5 The bolting for attaching major beams shall be provided with double
nuts or equivalent device.
GS 146-1
Column Internals PAGE 7
2.5.6 Fasteners must not be welded to tray components.
Where seal welding is required, for various tray sections please refer to
Section 4.4.
2.7.1 Tray manways shall provide a minimum access opening size of 380 mm
x 600 mm (15" x 24").
2.7.2 Tray manways shall be removable from both above and below the tray,
unless access is only from one side. The bolting shall be designed for
positive closure orientation.
2.7.5 Where practicable, access through an accumulator tray shall be via one
or more risers. The cap(s) covering the riser(s) concerned shall be
detachable.
Where a riser is used as a manway, its width shall not be less than 450
mm (18") in the longer direction and 380 mm (15") in the shorter
direction. The top of such a riser shall have a welded brim bar to
prevent injury to personnel. The maximum width shall be governed by
the need to provide an adequate number of risers to ensure good
vapour distribution.
2.8 Gasketting
2.8.1 Gaskets shall not be used to seal the tray active area.
2.8.2 Gaskets shall not be used to seal horizontal downcomer plates and
bolting bar junctions and any baffling that may be used in the base of
the column.
GS 146-1
Column Internals PAGE 8
Where a stringent (Cat 1) leak test is required, gaskets may not be used as it is
impossible to achieve a suitably leak tight tray.
2.8.4 Gasket material shall not contain any asbestos and shall be an asbestos
substitute suitable for both the process fluid and steam, up to the vessel
design temperature.
2.8.5 The use of packing, cements, caulking, etc. to achieve liquid or vapour
tightness or for any other purpose is prohibited.
The feed tray spacing should not be less than 600 mm (24").
2.9 Drainage
2.9.1 Trays shall have drain holes only where items, e.g. bubble caps, giving a
positive seal are used.
2.9.2 All seal pans and sumps shall have drain holes. Holes, where
appropriate, shall be located in the pan floor closest to the column
centre where appropriate to avoid vapour ingress into the downcomer
liquid.
2.9.3 For weir loads exceeding 1.2 m3/h.m3 (.5 USGPM/ft2) the drain hole
area should be based on 0.1% of the area to be drained. For lower weir
loads the basis should be 0.01%. Hole diameter should be between 5-
13 mm (0.2" - 0.5"), limited to a maximum of 2 holes per section.
2.9.4 Drain holes shall not be provided on trays or pans having a nozzle
positioned so as to allow complete drainage.
2.10.1 The mean outlet weir height shall be set within ±2.5 mm (0.1") of the
specified value. The difference between the maximum and minimum
height dimensions shall not exceed 3.0 mm (0.12").
GS 146-1
Column Internals PAGE 9
2.10.2 When inlet weirs are used, the height tolerance shall be ± 3.0 mm
(0.12").
2.10.4 Tray levelness and tray support levelness between high and low points
on the vessel circumference shall be:-
2.10.5 The location of tray support rings shall be set within the following
specified distances:-
2.10.6 The maximum uncovered joint opening between tray sections shall be 5
mm (0.2") in the shorter direction and 25 mm (1") in the longer
direction. The sum total of the areas of uncovered joint openings on
any one tray shall not exceed 1% of the active hole area on that tray.
2.10.7 The minimum overlap between the support ring and the outside
diameter of trays, pans and similar items shall be 20 mm (0.8").
2.11.1 Vortex breakers shall be fitted in all vessels at nozzles leading to pump
suctions. They are also required at all other pipe outlets where swirl
may interfere with the separating of phases, e.g. in the separation of
water in oil-water separators.
Vortex breakers may be of the cross type or grating type. The choice is usually
made according to the space available.
2.11.2 Vortex breakers shall be fitted to all internal pipes discharging liquid
from accumulator trays.
GS 146-1
Column Internals PAGE 10
2.12 Blanking on Sieve or Valve Trays
2.12.1 Blanking of active holes shall be achieved using flat plate blanking
strips bolted to the tray. Blanking strips shall be distributed uniformly
in the active area and should be between 40 mm (1.6") to 100 mm (4")
wide, so as to completely cover holes.
2.12.3 For trays using circular valves, valves shall be removed prior to
blanking.
2.12.4 Blanking shall not be used to adjust installed hole area to the specified
design value.
2.13.1 The manufacturer shall supply an installation procedure for each type of
tray to be supplied to include tolerances for installation and cross
referenced with drawings.
2.13.2 When tray installation takes place with the vessel in the horizontal
position, the manufacturer shall supply an installation procedure which
takes account of the vessel diameter and the out of roundness of the
vessel in the horizontal.
All sections of the trays including tray manways shall be fitted when
traying takes place in the horizontal.
2.13.3 The manufacturer shall supply the following extra material to allow for
field losses during installation:-
2.14.1 Refluxes shall enter an inactive tray area behind an inlet weir or false
downcomer acting as a seal dam. The inlet pipe shall be either an open
ended 'T' or a slotted branch distributor.
The choice will depend on the need to maintain a certain minimum exit velocity.
GS 146-1
Column Internals PAGE 11
2.14.2 The seal dam height shall be 50 mm (2") greater than the inlet pipe
nominal diameter up to a maximum dam height of 200 mm (8").
2.14.3 Branch pipe velocities shall be a maximum of 1 m/s (3.3 ft/sec) and slot
velocities a maximum of 2 m/s (6.6 ft/sec).
2.15.1 Liquid feeds shall enter through an open ended branch to discharge
vertically downward into the downcomer of the tray above the desired
feed location or via a slotted branch distributor discharging onto the
active side of the downcomer at the desired feed tray level.
2.15.2 Two phase, vapour-liquid, feeds shall enter the tray zone via a slotted
branch distributor which discharges against a wear plate attached to the
downcomer bolting bars.
2.15.4 Vapour inlets shall normally be a plain open inlet nozzle. The inlet
nozzle shall be oriented approximately at right angles to the flow of
liquid on the tray above.
2.15.5 For liquid feed pipes which cross the tray active area the minimum
clearance from the bottom of the pipe to the tray below shall be
350 mm (14").
2.15.6 High velocity (i.e. approaching sonic velocity) vapour inlet lines shall
be designed to dissipate the energy. The inlet pipe shall be sized to
limit the fluid velocity to a maximum of 70% sonic velocity. A
minimum straight run of 2 m shall be provided to the column entry and
the feed shall enter the tower tangentially. A hood shall be provided
extending at least to one quarter of the column circumference from the
column inlet point.
2.15.7 For high velocity inlets the minimum distance from the top of the inlet
pipe to the seal pan of the tray above shall be the greater of one pipe
diameter or 500 mm (20"). The minimum distance from the bottom of
the inlet pipe to the surface of any liquid below shall be the greater of
two pipe diameters or 600 mm (24").
GS 146-1
Column Internals PAGE 12
3. PACKED COLUMNS
3.1.1 All non random packing elements, support grids or structures, and
distributor systems and hold down grids shall be of sectional
construction with sections removable through the column manways.
Column manways shall be provided at the distributor system.
3.1.2 When a lifting beam is not available within the column any component
section referred to in 3.1.1 shall have a maximum weight of 50 kg (110
lb.) and a maximum length of 3000 mm (118"). All other components,
excluding structural beams, shall have a maximum weight of 120 kg
(265 lb.) and a maximum length of 4000 mm (157").
When a lifting beam facility can be provided within a column the weight
and length restrictions shall be governed by the ability to install
sectional components with the vessel in the vertical.
The factors which govern the maximum weight/length are those necessary to ensure
safe working in a confined space.
The quality of the liquid distribution is the key factor to good packing performance.
More even liquid distribution can be achieved with gravity distributors. Particular
emphasis is necessary in distillation duties where efficiency is important.
3.2.1 The standard material for all items referred to in 3.1.1 and random
packing elements shall be stainless steel. The specific grade of stainless
steel or alternative material shall be suitable for the process fluid.
Carbon steel may be suitable for the process fluids and carbon steel will not rust
less than stainless steel. Carbon steel is not recommended because of the
maintenance requirements. It is very difficult to prevent surface rust by excluding
air/water in a maintenance condition when column man entry is necessary.
Distortion under compression will effect both the efficiency and the hydraulic
capacity of a packing.
GS 146-1
Column Internals PAGE 13
rigidity, of the packing grade used. It is frequently 0.15 mm (0.006") but may with
some packing be as low as 0.1 mm (0.004") thick.
The design load shall include the weight of the packing elements plus
the weight of the process fluid when the section is operating in the fully
flooded regime. The minimum process fluid at flood shall be taken as
equivalent to 10% of the packing volume.
3.4 Packing
3.4.1 The supply of random packing shall be made only on the basis of filling
a given column diameter to a given depth. The manufacturer shall be
responsible for the supply of sufficient packing to take account of any
settlement allowance or dimensional variations.
Column sections are often non-circular and the packing elements per unit volume
quoted by manufacturers are averages. The supply of additional packing at the
outset is more cost effective than the remedial work necessary to meet the specified
height. Packing performance is almost always expressed in terms of packed height.
3.4.2 The depth of packing for each bed shall be stated by the manufacturer
to provide the number of mass transfer stages required and to prevent
physical distortion of the packing in service.
3.5.1 The liquid distribution to the top of the packed bed shall be uniform
over the vessel cross section for the whole design operating range.
This uniformity of flow shall be maintained as the liquid impinges on to
the top of the packed bed.
GS 146-1
Column Internals PAGE 14
< or = 26 < or = 1.0 > 261 > 80 20 0.8
27 to 61 1.0 to 2.4 121 to 260 37 to 79 30 1.2
> 61 > 2.4 < or = 120 < or + 37 40 1.6
Grid type Use manufacturers
limit
3.5.4 The design of the gravity distributor and any associated parting boxes
shall allow them to be levelled to within the tolerances specified in 3.8.
3.5.5 Liquid supply to the parting box shall be so arranged that aeration of
the liquid in the box and liquid swirl shall be minimised.
Despite best efforts to filter all liquid streams entering packed columns, industrial
fluids are not sufficiently clean to operate for prolonged periods with orifices below
2 mm (0.08") diameter. In many cases this chosen orifice diameter will be greater
than this minimum and must always be considered at the design stage, bearing in
mind the nature of the fluid being distributed and the process environment.
3.5.7 All orifices shall be formed with the punch exit on the liquid outlet side
of the distributor.
3.5.8 The manufacturer shall provide within the distribution system a means
to minimise particulate fouling of the distributor and define the method
of cleaning such systems.
Even in the cleanest process duties periodic cleaning will be a requirement.
External filters on all liquid feed lines should always be provided and located as
close as is practicable to the feed point. The filters will extend the period between
cleaning.
GS 146-1
Column Internals PAGE 15
3.5.10 A minimum liquid depth of 30 mm shall be used in parting box or
distributor channels.
The exact locations of nozzles to achieve the most uniform coverage is a function of
the characteristic of the particular nozzle selected. This is an area which should be
discussed with the owner.
3.6.2 Where ladder type distributors are selected, and where plain holes are
used, all internal burrs shall be removed which would otherwise affect
the liquid flowrate. Any pipe system shall have a vent hole to prevent
accumulation of vapour.
3.6.3 Feed pipework to the distributor shall be sized to limit the maximum
velocity to 1.5 m/s (4.9 ft/sec).
3.6.4 For fouling services the minimum free passage through the spray nozzle
shall be equivalent to a diameter of 3 mm (0.12").
3.7.1 All packed beds shall be provided with a bed limiter, the design of
which will be a function of the particular packing and distributor type
being used. In all cases the bed limiter design shall be such as to offer
the minimum possible coverage of the packing below. In this context
angle sections are not acceptable.
Where structured packing is used, any bars constituting the bed limiter
shall be orientated so that they do not lie along joins between adjacent
blocks of packing.
GS 146-1
Column Internals PAGE 16
3.7.2 Support grids shall be such as to impose the minimum resistance to
vapour flow.
3.8 Tolerances
The elevation difference between low and high points in the gravity
liquid distributor shall not exceed 2 mm (0.08").
4. ACCUMULATOR TRAYS
4.1.1 Accumulator tray risers shall be uniformly spaced over the tray.
The total riser area shall be consistent with the requirements of the column duty.
Thus in vacuum operation and operations where minimum pressure drop normally
is required, a maximum riser area is to be used consistent with the restraints
imposed by mechanical considerations.
4.1.2 Accumulator trays used for all vacuum columns and/or where all liquid
leakage has to be avoided, shall incorporate the following features:-
(b) vapour emergence area at the pouring end, or ends, of the cap
shall be fully blanked.
4.1.3 Accumulator tray caps shall be oriented so that liquid pouring from one
cap shall not enter the vapour emergence area of an adjacent cap.
4.2.1 Where practicable, access through an accumulator tray shall be via one
or more risers. The cap(s) covering the riser(s) concerned shall be
detachable.
Where a riser is used as a manway, its width shall not be less than
450 mm (18") in the longer direction and 380 mm (15") in the shorter
direction. The top of such a riser shall have a welded brim bar to
prevent injury to personnel.
GS 146-1
Column Internals PAGE 17
The maximum riser width should be governed by the need to provide an adequate
number of risers to ensure good vapour distribution.
4.2.2 Where the height of a riser used as a manway exceeds 450 mm (18") an
internal rung ladder shall be provided as necessary, with strengthening
of the riser.
Other methods of restraint may be used providing that both horizontal and vertical
movement of the beam is limited to that strictly required to contain the effects of
thermal expansion.
4.3.4 The design load shall include the weight of the internal element (with its
corrosion allowance) plus the following uniform downward loads at
design temperatures.
The greater of 6865 N/m2 (700 kg/m2, 143 psi) or a head of water to
the top of the vapour riser or the overflow weir. Calculations shall
exclude the corrosion allowance.
4.3.5 Allowable stresses for metals shall be as per the vessel code used for
the column design and construction, such as for example ASME Code
or BS 5500.
4.3.6 The distance between the upper edge of an accumulator tray riser cap
and the underside of the tray above or packing support above, shall not
be less than 300 mm (12"). When the riser is used as a manway the
minimum distance shall be 450 mm (18").
4.3.7 The manufacturer shall ensure that the trusses above the riser caps of
accumulator trays do not obstruct the flow of vapour from the risers.
GS 146-1
Column Internals PAGE 18
Such structural members shall be oriented so that they are parallel to,
and whenever possible immediately above, the riser caps.
4.4.1 All joints in seal pans and discharge pans shall be fully seal welded.
The minimum design thickness of seal pans and discharge pan
components shall be 3 mm (0.12"). Trays designated as total draw-off
trays shall be designed to have all seams continuously welded, including
seams in risers and the peripheral seal with the tray support ring.
Accumulator trays with clamps and bolting have often failed in service. The
presence of gasketting has often made failure more likely. Fully welded
construction has proved to be the solution to minimising failures. Long experience
has shown that provided the tray is designed for full seal welding, damage due to
thermal stresses will not occur even though there may be some minor localised
panel buckling.
4.4.2 Seal welding shall normally be using a continuous fillet weld above the
attachment and an intermittent weld below. Where the duty is specified
as corrosive, continuous fillet welds should be used above and below.
5. VESSEL FEATURES
5.1.1 Internal distribution pipes shall have flanged and gasketted connections
to facilitate installation and removal.
5.1.2 Internal piping shall be the same nominal alloy as the inside surface of
the vessel. For ferric, austenitic or high alloys, such as Inconels, the
minimum wall thickness shall be schedule 10 or 3/16th inch (4.7mm),
whichever is less. For carbon steel or low chrome steels, the minimum
wall thickness shall be schedule 80.
GS 146-1
Column Internals PAGE 19
5.1.3 Internal flanges shall be ASME/ANSI Class 150 weld neck or slip-on
type unless otherwise approved. Internal flanges shall be of a
compatible metallurgy with the material specified for the internal pipe.
Internal flange bolting shall be sequentially tightened, and double nuts
used to prevent loosening.
The results of the rating calculations and related mechanical data shall
be summarised on the data sheets. The information shall be furnished
to the owner's engineer for their review prior to commencement of
fabrication.
6.2 Drawings
6.2.1 The following dimensions shall be referenced to the tray floor and be
consistent with the process and mechanical data sheets:-
6.2.2 Plan and elevation drawings shall be provided by the manufacturer for
approval by the purchaser before fabrication commences, indicating
materials specifications and all design and assembly dimensions. These
drawings should contain the following minimum design information,
where applicable, relating to every separate design section of the tower.
GS 146-1
Column Internals PAGE 20
(g) valve thickness.
Note:- the above measurements shall apply to actual sizes as used for
process design, and not to measurements that might be used for
fabrication purposes.
6.2.3 One original transparency and two copies of each Final Fabrication
drawing shall be supplied to the Owner.
6.2.4 The orientation in degrees, and the elevation, shall be marked on all
drawings where appropriate.
6.3.1 With the exception of packings, all items of equipment shall be marked
with a part number for identification and easy assembly. Like parts may
bear the same number. Supporting documentation will cross reference
between assembly procedures and drawings. Structured packing
elements shall not be individually marked, but only the housing
container. Items shall normally be marked by metal-stamping. For
materials subject to stress corrosion cracking these shall be marked
using an electric discharge pen (pyrograph) or equivalent.
6.3.2 A list with the part numbers of the items within the container shall be
provided both inside and outside all packing containers.
GS 146-1
Column Internals PAGE 21
6.3.4 Structured packings shall be packed in weather proof boxes. Consistent
with standard box sizes, elements which make up complete vessel cross
sections shall be packed together for large diameter vessels.
6.3.6 Carbon steel parts shall be protected in a dry storage area. Austenitic
stainless steel components shall never be exposed to wetting by salt
water or salt spray. Protective packaging or a suitable removable
coating shall be used to prevent such exposure.
6.4.1 One tray per type, including accumulator trays, shall be assembled in
the manufacturer's shop to the extent necessary to check dimensions.
Examination shall be by the purchaser or his representative.
6.4.2 All accumulator trays shall be subject to a water leak test at site. The
permitted leakage shall be as per the schedule below:-
The water leak tests will be made (with drain holes plugged) at the overflow weir
height or chimney height, as applicable.
6.4.3 One gravity distributor per type as used for fractionation service shall
be tested with water in the fabrication shop before dispatch. Liquid
inlet means to the distributor parting box shall be the same as that to be
used in the column. The tests shall be performed at design maximum
and minimum flowrates as follows:-
Samples should be taken from each part of the parting box that
discharges into a separate channel.
GS 146-1
Column Internals PAGE 22
Acceptance criteria: Liquid distribution at 50% of the maximum design
flowrate, or a specified minimum design flowrate, to be within + or -
4% of the mean.
Approximate number of
Column diameter
holes from which liquid is
mm ins collected from each location
< 900 < 36 1
900 - 1800 36 - 70 5
> 1800 >70 10
Acceptance criteria: The distance between the liquid level and parting
box/channel/pan top must be a minimum of 10% of the parting
box/channel/pan depth. Under no conditions will an overflowing
system be accepted.
6.4.4 When a spray distributor is used for a VDU wash zone, or similar zone,
it shall be tested with water in the fabrication shop before dispatch.
Tests shall be performed at design maximum and minimum flowrates.
A nozzle inlet pressure versus flowrate relationship shall be derived.
Nozzle dimensions shall be checked against manufacturers data.
In the event that the downcomer does not form a continuous seal with
the bolting bars, the downcomer shall be reassembled using a gasket.
GS 146-1
Column Internals PAGE 23
7. GUARANTEES
7.1 Mechanical
7.1.1 The manufacturer shall guarantee all items supplied by him against
defective material, poor workmanship, improper design and failure
within design loadings.
7.1.2 The manufacturer shall repair or replace free of charge any defective
material or workmanship found within the guarantee period.
7.2 Process
7.2.1 The manufacturer shall guarantee the ability to handle the vapour and
liquid loads over the specified operating range whilst retaining
efficiency, when hydraulic loadings are supplied by the purchaser.
7.2.2 The manufacturer shall guarantee the separation and the hydraulic
throughput when the process design and the hydraulic design is his
responsibility.
7.2.3 The manufacturer shall replace free of charge any new items required to
meet the process guarantees.
7.2.4 The manufacturer shall guarantee that the design and fabrication of
liquid distributors for packed columns will meet the criteria for
acceptance given in section 6.4.3 and 6.4.4.
8. REGIONAL ANNEX
8.1 USA
This is a requirement of BP's refineries in the USA which at the moment (Sept '95)
is not strictly required elsewhere.
GS 146-1
Column Internals PAGE 24
APPENDIX A
Definitions
grid packings: ordered packing manufactured from cut out metal strips
structured packing: ordered packing manufactured from pressed sheet metal sheets
Abbreviations
CS Carbon steel
FRI Fractionation Research Incorporated
HF Hydrofluoric acid
GS 146-1
Column Internals PAGE 25
APPENDIX B
A reference invokes the latest published issue or amendment unless stated otherwise.
British Standards
BS 5750 Quality System for design, development, production installation and Part 1
servicing.
American
GS 146-1
Column Internals PAGE 26