0% found this document useful (0 votes)
33 views

DS-85-Error-Code-List

The document provides a comprehensive list of error codes for the SIGALARM Model 210 central unit, detailing potential causes and elimination methods for each error. It includes 18 specific error codes related to various operational issues, such as range exceedance, sensor failures, and programming errors. Users are advised to refer to the respective sections for troubleshooting guidance and to contact SkyAzúl service for unlisted error messages.

Uploaded by

Gerardo Lizardo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

DS-85-Error-Code-List

The document provides a comprehensive list of error codes for the SIGALARM Model 210 central unit, detailing potential causes and elimination methods for each error. It includes 18 specific error codes related to various operational issues, such as range exceedance, sensor failures, and programming errors. Users are advised to refer to the respective sections for troubleshooting guidance and to contact SkyAzúl service for unlisted error messages.

Uploaded by

Gerardo Lizardo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

SIGALARM

MODEL 210

DS85/0002
Central unit / console

DS-85 Error Code List


Error Codes 1

18 ERROR CODES
The following Error Code Table gives a brief description of Error Codes elimination. Refer to the
noted sections for detailed Troubleshooting information.

Error Code Error Possible Cause Elimination


E01 Fallen below radius • Fallen below the • Luff down the boom to a
range or angle range minimum radius or gone radius or angle specified in
exceeded past the maximum angle the load chart.
specified in the respective
load chart due to luffing
up the boom too far
E02 Radius range • Gone past the maximum • Luff up the boom to a radius
exceeded or fallen radius or fallen below the or angle specified in the load
below angle range minimum angle specified chart.
in the respective load
chart due to luffing down
the boom too far
E03 Non-permitted slewing • The slewing zone with • Slew to permitted area
zone (no load area) load is not permitted
E04 Operating mode not • An incorrect operating • Set the correct operating
acknowledged or non mode has been selected mode for the operating
permitted slewing configuration in question.
zone Refer to Operator’s
Handbook.

• The boom is in a non- • Slew the boom to a


permitted slewing zone permitted area. Refer to
Section 8.
E05 Prohibited length • Boom has been extended • Extend/retract boom to the
range either too far or not far correct length
enough, e.g. if it is
prohibited to go beyond a
certain maximum boom
length or with load curves
for jibs where the main
boom has to be extended
to a certain length
• Length sensor adjustment • Retract boom. Check the
has changed, e.g. the prestress of the cable reel
cable slid off the length (cable must be taut). Open
sensor reel. the length sensor and
carefully turn the length
sensor pot counterclockwise
until the detent by means of
a screw driver
• Clutch between length • Replace the complete clutch
sensor pot and drive is including drive wheel and
defective adjust length sensor pot as
described above

SkyAzúl, Equipment Solutions www.skyazul.com 301-371-6126


2 Service Manual DS 85

Error Code Error Possible Cause Elimination


E11 Fallen below lower • Length potentiometer is • Replace length
limit value for defective potentiometer, see
measuring channel section Length Sensing
"length main boom"
E12 Fallen below the • Pressure transducer is • Replace pressure
lower limit value in defective. transducer, see section
the measuring Pressure Sensing
channel "pressure
piston side"

E13 Fallen below lower • refer to E12 • refer to E12


limit value in the
measuring channel
"pressure rod side"
E14 Fallen below lower • Force transducer • Replace force
limit value in defective transducer
measuring channel • Replace sensor unit
"force"
E15 Fallen below lower • Angle potentiometer • Replace angle sensor,
limit value in defective see section Angle
measuring channel Sensing
"angle main boom"

E16 Fallen below lower • Angle potentiometer • Refer to E-15


limit value in defective
measuring channel
"angle 2"

E17 Fallen below lower • Length potentiometer • Replace length sensor,


limit value "length defective see section Length
telescope I (+II)" Sensing

E1A Fallen below lower • Cable between the • Check cable as well as
limit value in central unit and the plugs, replace, if need
measuring channel slewing angle sensor be.
"slewing angle 1". defective or loose.

• Slewing angle • Replace slewing angle


potentiometer is defective sensor
E1B Fallen below lower • refer to E1A • refer to E1A
limit value in
measuring channel
"slewing angle 2"
E21 Upper limit value in • refer to E11 • refer to E11
measuring channel
“main boom length”
has been exceeded.

SkyAzúl, Equipment Solutions www.skyazul.com 301-371-6126


Error Codes 3

Error Code Error Possible Cause Elimination


E22 Upper limit value in • refer to E12 • refer to E12
measuring channel
“pressure piston
side” has been
exceeded
E23 Upper limit value in • refer to E12 • refer to E12
measuring channel
“pressure rod side”
has been exceeded.
E24 Upper limit value in • refer to E14 • refer to E14
measuring channel
“force” has been
exceeded.
E25 Upper limit value in • refer to E15 • refer to E15
measuring channel
“main boom angle”
has been exceeded.
E26 Upper limit value in • refer to E16 • refer to E16
measuring channel
“angle 2” has been
exceeded.
E27 Upper limit value in • refer to E17 • refer to E17
measuring channel
“length telescope I
(+II) has been
exceeded.
E2A Upper limit value in • refer to E1A • refer to E1A
measuring channel
“slewing angle 1”
has been exceeded
E2B Upper limit value in • refer to E1A • refer to E1A
measuring channel
“slewing angle 2”
has been exceeded
E31 Error in the system • The system program file • Upload valid system
program is defective. software

• Flash-EPROM defective Replace central unit


E37 Error in the logical • System program file is • Upload valid system
program flow defective software

• Flash-EPROM defective • Replace central unit


E38 System program • The system program in • Upload valid system
and crane data file the LMI does not match to program file or the valid
do not match. the programming in the crane data file
crane data file
E39 System program • The system program in • Upload valid system
and load chart file the LMI and the program file or the valid
do not match programming in the load load chart file
chart file do not match.

SkyAzúl, Equipment Solutions www.skyazul.com 301-371-6126


4 Service Manual DS 85

Error Code Error Possible Cause Elimination


E43 Error in the • Write/read memory • Replace central unit
write/read memory, (RAM) or central unit
(RAM) defective.
E47 Error in the • The CRC sign of the • Restart the LMI
monitored write/ monitored write/read
read memory. memory is wrong

The CRC • The buffer battery is • Replace buffer battery


verification of the discharged (< 2V at on the central unit.
monitored 1kOhm).
write/read memory
provides an
incoherent result • Central unit defective. • Replace central unit
E51 Error in the crane • No valid data in the crane • Upload valid crane data
data file data file. file

• Flash-EPROM defective • Replace central unit


E52 Error in load chart • No valid data in the load • Upload valid load chart
file. chart file file

• Flash-EPROM defective • Replace central unit


E56 Error in crane data • No valid data in the crane • Restore or upload valid
file. data file during crane data file
calibration.

• Flash-EPROM defective • Replace central unit


E57 Error in serial crane • Calibration data file does • Upload calibration data
data file. not contain valid data. file

• Flash-EPROM defective • Replace central unit


E60 The number of the • No valid data in the load • Upload valid load chart
selected File base chart file file
and the
programmed value
are not identical
• Base number not • Program the correct
programmed base number (1 for
base 1, 2 for base 2)
• Load chart file wrongly • Check base
programmed programming in the load
chart file.
E61 Error in the CAN • CAN Bus cable between • Check the connection
bus data transfer for the central unit and the between the central unit
all CAN units sensor units defective or and the sensor units
not connected. (wiring harness). See
section CAN-Bus
Communication
• Short circuit in a CAN Bus • Replace Can Bus cable
cable

SkyAzúl, Equipment Solutions www.skyazul.com 301-371-6126


Error Codes 5

Error Code Error Possible Cause Elimination


• Can bus port in the • Replace the central unit
central unit defective
• Blown fuse in console • Replace 2 amp fuse
E62 Error in the can bus • Cable between the • Check the cable to the
data transfer of the central unit and the sensor unit (wiring
pressure transducer sensor unit defective or harness). See section
sensor unit not connected. CAN-Bus
Communication
• Blown fuse in console • Replace 2 amp fuse
• Sensor unit is defective • Replace the sensor unit
E63 Error in the can bus • The analog values of the • Replace the sensor unit
pressure transducer sensor unit are invalid See section CAN-Bus
sensor unit Communication.
E64 Error in the can bus • Cable between the • Check the cable to the
data transfer of the pressure transducer and sensor unit. See section
length/angle sensor cable reel defective or not CAN-Bus
unit connected. Communication
• Sensor unit is defective • Replace the electronic
board in the cable reel,
see section CAN-Bus
Communication
E65 Error in the can bus • Angle sensor defective • Replace the angle
length/angle sensor sensor, see section
unit CAN-Bus
Communication
• Length sensor defective • Replace the length
sensor, see section
CAN-Bus
Communication
• Sensor unit is defective • Replace the electronic
board in the cable reel,
see section CAN-Bus
Communication
E66 Error in the can bus • See E62 • See E62
data transfer of the
2nd length/angle
sensor unit
E67 Error in the can bus • See E63 • See E63
of the 2nd length
/angle sensor unit
E68 Error in the can bus • See E62 • See E62
data transfer of the
force sensor unit
E69 Error in the can bus • See E63 • See E63
force sensor unit

SkyAzúl, Equipment Solutions www.skyazul.com 301-371-6126


6 Service Manual DS 85

Error Code Error Possible Cause Elimination


E80 Error in the slewing • The difference between • See section Slewing
angle measurement the average of the Sensing
slewing angle and one of
the wipers of the slewing
potentiometer is out of the
tolerance
E84 Wrong rigging • The selected rigging • Select another rigging
condition. condition is not contained condition
in the crane data file.
• Check the programming
in the crane data file.
E85 Error in the radius • The computed radius is • Check the programming
determination too small (negative in the crane data file.
deflection)

E89 Operating mode • The operating mode on • Select operating mode


switchover with the console has been without load on the
load. switched over with the boom
boom loaded.
EAB Short circuit in the • Short circuit in the A2B • Replace A2B switch
A2B switch circuit switch

• Short circuit in the cable • Replace cable to the


to the A2B switch A2B switch
EAC A2B switch circuit • Disconnected cable in the • Connect or replace
disconnected A2B switch cable in the A2B switch

• Disconnected cable to the • Connect or replace


A2B switch cable to the A2B switch
EAD No valid A2B switch • Sensor wrong function • Replace A2B switch
status
• CAN bus delay • Replace cable to the
A2B switch