Psens Davs Multiple-Pressure Transducers: With Canopen Interface

The Hirschmann pressure transducers are designed for measuring high static and dynamic pressure values in harsh environments, featuring high accuracy and a CANopen interface for easy integration. They are suitable for hydraulic systems in cranes and construction equipment, offering a rugged design and reliable performance under extreme conditions. Technical specifications include various pressure ranges, operating temperatures, and a compact design with a waterproof connector.

Uploaded by

majd917mahmoudi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views2 pages

Psens Davs Multiple-Pressure Transducers: With Canopen Interface

The Hirschmann pressure transducers are designed for measuring high static and dynamic pressure values in harsh environments, featuring high accuracy and a CANopen interface for easy integration. They are suitable for hydraulic systems in cranes and construction equipment, offering a rugged design and reliable performance under extreme conditions. Technical specifications include various pressure ranges, operating temperatures, and a compact design with a waterproof connector.

Uploaded by

majd917mahmoudi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Controls Consoles SLIs Sensors Service

pSENS DAVS MULTIPLE-PRESSURE TRANSDUCERS


with CANopen Interface

The Hirschmann pressure transducers measure high static  High accuracy


and dynamic pressure values of liquids or gases in rough  High overload capacity and endurance limit
operating environments. Measuring precision is main-
 Temperature compensation
tained even during continuous operation at extremely
 Very rugged design
dynamic pressure. The CANopen interface makes a simple
integration of the pressure transducers into CANopen  Great operating reliability under extreme conditiones
networks possible and supports an easy installation of  Cost effective solution
the entire system.
These pressure transducers are preferably used as part
of a Hirschmann load moment indicator system or
Hirschmann control system in hydraulic systems for
cranes. Since the pressure transducers are suitable for
rough environments, they also offer an ideal solution for
control and automatic control applications in hydraulic
systems of construction equipment, and conveyor and
lifting equipment.
TECHNICAL DATA

Design and Functioning Dimensions


The pressure transducers consist of a multiple sensor
2-channel
with 2 or 4 sensors optional made of corrosion resistant
steel. The signal is acquired through extension restraining
strips in full bridge connection with each located on a
diaphragm shaped connector. The amplification, the
digitalization of the measuring signal, and the transfer
of the measuring information are carried out through
an integrated sensor module with CAN connection and
CANopen protocol according to CiA DS 301 commu- 4-channel

nication profile and DS401 device profile. The pressure


transducers come with a pressure connector with stand-
ardized internal thread. A water-proof M12 plug provides
the electrical connection.

Description pSENS DAVS Description pSENS DAVS

Nominal pressure 300 bar Operating temperature -25 °C to +70 °C


Permissible excessive Storage temperature -40 °C to +85 °C
1200 bar
pressure Temperature of the
Input variables

2400 bar -40 °C to +100 °C


Bursting pressure measuring material
Mechanical connection 2x (4x) internal thread M16 x 1.5 Protection system
IP 65
Environment

according to DIN 40050


Starting moment max. 80 Nm
Interference prot. 1
according to EN 50082-2 2
Parts touching stainless steel 1.4542
measuring material and 1.4571 Interference
acc. to EN 50081-2 and EN 50081-1
transmission 1
Linearity ±0.5% FS
Permanent shock
Output Variables

TC zero point ±0.03% FS / K (3 axles, 1000 shocks/axle)


IEC 68-2-29 / 10 g / 6 ms
TC span ±0.03% FS / K Noise
(10 ... 150 Hz / 0.05 g2/Hz)
EC 68-2-64 / 2.6 geff
Hysteresis ±0.2% FS
Long term stability ±0.2% FS / year Dimensions 170 x 74 x 79 mm ( W x H x D )
Other

Output signal CANopen interface Positioning anywhere

CAN Bus protocol CAN 2.0 B, standard identifier (11 bit) Weight 0.8 kg
Output Signal

1
when connected with shielded cable (shield placed on top of connector housing).
CANopen protocol CiA DS 301, device profil acc. to DS 401 2
also acc. to EN 61000-6-2, however without transient voltage IEC 61000-4-5
Physical transfer 2 wire, 5 V level, CAN high speed
ISO 11898-2 (24 V short circuit prot.)

Operating voltage 10 - 30 V DC Pressure


Versions Description Order-No.
Connection

range
Electrical

Current consumption 80 mA
pSENS DAVS 314/14 300 bar 2-channel* 606 286
Outputs polarity protection / short ciruit proof
pSENS DAVS 614/14 600 bar 2-channel* 606 966
Plus M12x1 and • pin 1 shield contact
Pin Configuration

Soket M12x1 • pin 2 + Ub pSENS DAVS 314/10 300 bar 4-channel* 605 982
(CiA DR-303-1 7.2 / • pin 3 common pSENS DAVS 354/10 350 bar 4-channel** 607 091
DeviceNet ) • pin 4 CAN high pSENS DAVS 354/11 350 bar 4-channel* 607 318
• pin 5 CAN low
* without moving load, ** with moving load

Hirschmann Automation and Control GmbH


04-2007/417744

Branch Office Ettlingen


Hertzstraße 32-34 • 76275 Ettlingen
Tel: +49 7243 709-0 • Fax: +49 7243 709-3222
www.hirschmann-ac.com