This paper outlines recommended best tuning practices for Windows iSCSI Initiator configurations connecting to the MD3600i series array. It focuses only on implementations that use the Microsoft virtual miniport implementation. Hardware initiators that provide their own hardware Storport miniport implementation are beyond the scope of this paper.

Uploaded by

Adam Van Haren
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views8 pages

Best Tuning Practices For Power Vault MD3600 Series Storage Arrays

This paper outlines recommended best tuning practices for Windows iSCSI Initiator configurations connecting to the MD3600i series array. It focuses only on implementations that use the Microsoft virtual miniport implementation. Hardware initiators that provide their own hardware Storport miniport implementation are beyond the scope of this paper.

Uploaded by

Adam Van Haren
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

MD3600i Series Array Best Tuning Practices

A Dell Technical White Paper

Dell PowerVault Series

MD3600i Series Array Best Tuning Practices

THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. 2010-2011 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell. Dell, the DELL logo, and the DELL badge, PowerConnect, and PowerVault are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

March 2011

Page ii

MD3600i Series Array Best Tuning Practices

Contents
Introduction ................................................................................................................ 2 Configuration ............................................................................................................... 2 Recommendations ......................................................................................................... 2 NDIS Only Single Adapter Port ........................................................................................ 2 NDIS Only Two Adapter Ports ......................................................................................... 3 Hardware Initiator Single Port........................................................................................ 3 Hardware Initiator Dual Port ......................................................................................... 6 Conclusion .................................................................................................................. 6

Page 1

MD3600i Series Array Best Tuning Practices

Introduction
This paper outlines recommended best tuning practices for Windows Microsoft iSCSI Initiator configurations connecting to the MD36xxi array. This paper focuses only on implementations that use the Microsoft virtual miniport implementation. Hardware initiators that provide their own hardware Storport miniport implementation are beyond the scope of this paper and will not be covered. Therefore, the information that follows is based on typical customer Windows configurations that run on NDIS drivers only, or NDIS driver implementations that also provide iSCSI offload capabilities. The network cards used to generate this information are the 10GBase-T Intel Server AT adapter, and the Dell Broadcom 57710 10GBase-T adapter.

Configuration
The host configuration used in this report is an R910 with 32GB of memory installed; two 10GBase-T PCIe GEN2 x8 adapters installed in PCIe GEN2 x8 electrical slots; and Windows 2008 Standard SP2 installed. Host and MD36xxi connect to a Dell Power Connect 8024 10GBase-T switch with jumbo frames enabled. Default settings are used on Microsoft iSCSI Software Initiator.

Recommendations
The following recommendations are based on a single host connectivity solution that has one or two 10GBase-T single port network adapters installed, and a duplex MD36xxi configuration. The host is a Windows 2008 Standard server with SP2 and MD36xxi multi-path host software installed.

NDIS Only Single Adapter Port


For a single network adapter, four iSCSI connections are recommended between host and arrayone connection per array host port, two connections per array controller. The recommend MTU size is the standard Ethernet frame size of 1518 bytes; jumbo frames are not recommended. If you are using Intel and your system supports input/output acceleration technology (IOAT), we recommend that this feature and the IOAT drivers be installed. We also recommend that you enable RSS in the operating system, configure the number of RSS queues on the adapter to be equivalent to the number of CPU cores on the system, and set the receive and transmit buffer size to maximum values. Use the default value for all other settings. For Broadcom, we recommend that Chimney and RSS support be enabled and default adapter settings be used. For a single 10GBase-T port implementation, four iSCSI connections are recommended between host and target.

8024 SW R910 N0 N1

0 1 0 1

C0

C1

Page 2

MD3600i Series Array Best Tuning Practices

NDIS Only Two Adapter Ports


For a two network adapter configuration, four iSCSI connections are recommended between host and arrayone connection per array host port, two connections per array controller. The recommend MTU size is the standard Ethernet frame size of 1518 bytes; jumbo frames are not recommended. If you are using Intel and your system supports IOAT, we recommend that this feature and the IOAT drivers be installed. We also recommend that you enable RSS in the operating system, configure the number of RSS queues on the adapter to be equivalent to the number of CPU cores on the system, and set the receive and transmit buffer size to maximum values. Use the default value for all other settings. For Broadcom, we recommend that Chimney and RSS support be enabled and default adapter settings be used. For a two 10GBase-T port implementation, four iSCSI connections are recommended between host and target. C0

0 R910 N0 N1 1 0 1

C1

Hardware Initiator Single Port


For a single network adapter, two iSCSI connections are recommended between host and arrayone connection per array host port and one connection per array controller. Enable jumbo frames on the host, switch, and array. Set the host adapter MTU to 4500 bytes, and set switch and MD36xxi MTU size to a value greater than 4500 byte (a 9000 byte MTU size is recommended for both switch and array). The Dell Modular Disk Storage Manager can be used to configure jumbo frames on the MD36xxi.

R910

8024 SW N0

0 1 0

C0

C1

N1

Page 3

MD3600i Series Array Best Tuning Practices To configure jumbo frames on the array, open a management connection with the array, select the Setup tab on the main screen, and then click Configure iSCSI Host Ports. The following management screen displays:

Page 4

MD3600i Series Array Best Tuning Practices Click the Advanced Host Port Settings button in the lower left of the window to display the following configuration window:

In the Jumbo Frames section, check the Enable jumbo frames box and set the MTU size to 9000 bytes/frame. Click the OK button. Perform this operation on each MD36xxi iSCSI host port.

Page 5

MD3600i Series Array Best Tuning Practices

Hardware Initiator Dual Port


For a two network adapter configuration, four iSCSI connections are recommended between host and arrayone connection per array host port, two connections per array controller. Enable jumbo frames on the host, switch, and array. Set the host adapter MTU to 4500 bytes, and set switch and MD36xxi MTU size to a value greater than 4500 byte (a 9000 byte MTU size is recommended for both switch and array). The Dell Modular Disk Storage Manager can be used to configure jumbo frames on the MD36xxi. 8024 SW R910 N0 N1

0 1 0 1

C0

C1

Conclusion
In general, when configuring MS iSCSI Initiator on a system running NDIS drivers on a 10GBase-T adapter, we recommend no more than four iSCSI sessions between host and array. This will provide adequate streaming capability between host and array without overwhelming the host adapter port. For iSCSI hardware initiators, the number of iSCSI connections between host and array can be fewer for the single adapter port case. These guidelines are meant to provide a general configuration topology based on a typical 10GBase-T host connection profile, but every situation is unique and may require a different set of guidelines. If this is the case, contact Dell Technical Support for further assistance.