0% found this document useful (0 votes)
57 views12 pages

Fly Generation Change PNOZmulti 2 1007002-EN-01

The PNOZmulti Classic and PNOZmulti Mini are being phased out, with the last order date set for September 30, 2024, and last delivery by December 31, 2024. Users are encouraged to migrate to the PNOZmulti 2, which offers guided migration through the PNOZmulti Configurator software, ensuring compliance with safety standards. Important restrictions and changes in functionality are noted, including the lack of support for certain devices and the need for thorough safety checks post-migration.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views12 pages

Fly Generation Change PNOZmulti 2 1007002-EN-01

The PNOZmulti Classic and PNOZmulti Mini are being phased out, with the last order date set for September 30, 2024, and last delivery by December 31, 2024. Users are encouraged to migrate to the PNOZmulti 2, which offers guided migration through the PNOZmulti Configurator software, ensuring compliance with safety standards. Important restrictions and changes in functionality are noted, including the lack of support for certain devices and the need for thorough safety checks post-migration.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

PNOZmulti generation change

PNOZmulti Classic and PNOZmulti Mini – phasing out, discontinuation


and migration to the configurable, safe small controllers PNOZmulti 2
Configurable safe small controllers PNOZmulti – Generation change
Phasing out and discontinuation of PNOZmulti Mini / PNOZmulti Classic

Last Order: 30.09.2024

Last Delivery: 31.12.2024

Repair guarantee:
in accordance with the Pilz
General Terms and Conditions
until at least 2 years after PNOZmulti 2 – recommended successor to
product discontinuation PNOZmulti Classic / PNOZmulti Mini
– Information at www.pilz.com/pnozmulti

April 2024 Generation change PNOZmulti 2


Configurable safe small controllers PNOZmulti – Generation change
Phasing out and discontinuation of PNOZmulti Mini / PNOZmulti Classic

Migration of user program/project to PNOZmulti 2nd generation


Guided migration in the PNOZmulti Configurator software tool
– Version 10.14.x "long-term-supported" version  Link to download the software
– This version must be used to migrate PNOZmulti Classic projects to PNOZmulti 2
– it can be used to migrate PNOZmulti Mini projects to PNOZmulti 2.

PNOZmulti Mini can be automatically migrated to PNOZ m B0.1 when the project is opened in the PNOZmulti
Configurator version 11.x.x
– If necessary, PNOZ m B0.1 can be migrated to other PNOZmulti 2 base units, using the Configurator version 11.x.x
– Link to download the software PNOZmulti Configurator V11.x.x

If a user program (project) is migrated with the software tool PNOZmulti Configurator, it is essential to carry out a
complete safety check before the machine or plant can be operated again! All connected sensors and actuators must
be tested to ensure that they function in the manner required by the standards!

April 2024 Generation change PNOZmulti 3


Configurable safe small controllers PNOZmulti – Generation change
Phasing out and discontinuation of PNOZmulti Mini / PNOZmulti Classic

Please note! The following restrictions apply


No replacement of coated version devices  Software migration for coated version generally possible to non-coated
versions
No replacement when using the PNOZ mm0.2p with 4 x PNOZ mml1p Multi Link
PNOZmulti Mini  when using PNOZsigma extensions! Attention!
– E.g. PNOZ m EF 2DOR outputs are only 1-channel (PL c), with PNOZ s22 these are 2-channel (PL e)
PNOZmulti 2 analogue inputs 0...24 mA, no more voltage range -10..+10V !
Fieldbus has other data areas  Fieldbus master must be adapted
PSEN op2S and op4S are NOT certified for the PNOZmulti 2
PNOZmulti 2 does not support Safe Ethernet Connection

If a user program (project) is migrated with the software tool PNOZmulti Configurator, it is essential to carry out a
complete safety check before the machine or plant can be operated again!
All connected sensors and actuators must be tested to ensure that they function in the manner required by the
standards!

April 2024 Generation change PNOZmulti 4


Safe small controllers PNOZmulti 2
Overview of basic devices

April 2024 Generation change PNOZmulti 5


Easy migration in the PNOZmulti Configurator software tool
Two software versions for the changeover!

If a user program (project) is migrated with the


Open project in the Existing project PNOZmulti Configurator software tool, it is
PNOZmulti
Configurator * with "old" essential to carry out a complete safety check
hardware before the machine/plant can be operated again!
Select replacement
base unit in the All connected sensors and actuators etc. must be
software
checked and tested to ensure that they function
in the manner required by the standard!
Configurator
automatically selects
"new" hardware

Migration report is Migrated hardware


prepared Notes/assignment list are
also adopted

Final check by the


user

April 2024 Generation change PNOZmulti 6


Migration from PNOZmulti Classic to PNOZmulti 2

…to PNOZmulti 2
PNOZ m C0 PNOZ m B0.1 PNOZ m B0 PNOZ m B1 PNOZ m B1
From PNOZmulti Classic …

(772105) (772104) (772100) (772101) Burner


up to FW (772103)
2.x**
PNOZ m0p V10.14 + V10.14 + V10.14 V10.14 V10.14
(773110, 773110) V11.x* V11.x*

PNOZ m1p V10.14 + V10.14 + V10.14 V10.14 V10.14


(773100, 773103) V11.x* V11.x*

PNOZ m2p V10.14 + V10.14 + V10.14 V10.14 V10.14


(773120, 773123) V11.x* V11.x*

PNOZ m3p V10.14 + V10.14 + V10.14 V10.14 V10.14


(773125, 773126) V11.x* V11.x*
* Migration in V10.14 to PNOZ m B0 or B1, then further migration in V11.1.x to PNOZ m C0 or B0.1
** When using the PNOZ m B0 FW3.x, further migration to V11.x is required
Note: coated version units can be migrated to PNOZmulti 2. However, these are not available as a coated version. This affects the coated version
units PNOZ m1p (773105) and PNOZ m1p ETH (773104). Alternatively, the PSS 4000 automation system can be used

April 2024 Generation change PNOZmulti 7


Safety systems PNOZmulti Classic
Phasing out and discontinuation

Last Order: 30.09.2024 Key data


Last Delivery: 31.12.2024 Item number: 773100 - 773830 + clamps
Repair guarantee: in accordance with the Designation: PNOZmulti Classic incl. expansions and fieldbus modules
Pilz General Terms and Conditions until at
Number of variants: 54 + terminals (14)
least 2 years after product discontinuation

PNOZ m B1 or PNOZ m B1 Burner

PNOZmulti Classic System

OR

PNOZ m B0

Coated
PSS 4000-T
version?

April 2024 Generation change PNOZmulti 8


Migration from PNOZmulti Mini to PNOZmulti 2

... to PNOZmulti 2
PNOZ m C0 PNOZ m B0.1 PNOZ m B0 PNOZ m B1 PNOZ m B1
From PNOZmulti Mini …

(772105) (772104) (772100) (772101) Burner (772103)


PNOZ mm0p V10.14 + V11.x* automatically in V 10.14 or V 10.14 or V11.x.x V 10.14 or
V11.x.x V11.x.x ** ** V11.x.x **
(772000)
PNOZ mm0.1p V10.14 + V11.x* automatically in V 10.14 or V 10.14 or V11.x.x V 10.14 or
V11.x.x V11.x.x ** ** V11.x.x **
(772001)
PNOZ mm0.2p V10.14 + V11.x* automatically in V 10.14 or V 10.14 or V11.x.x V 10.14 or
V11.x.x V11.x.x ** ** V11.x.x **
(772002)
PNOZ mm0p-T "coated version" - software migration possible, PNOZmulti 2 hardware not available as "coated version"!
(772010)
* Migration in V10.14 to PNOZ m B0 or B1, then further migration in V11.1.x to PNOZ m C0 or B0.1
**Migration from PNOZmulti Mini to PNOZ m B0.1 and then migration from PNOZ m B0.1 to PNOZ m B0/B1/B1 Burner.
Alternatively migration in Software version V10.14

April 2024 Generation change PNOZmulti 9


PNOZmulti Mini – configurable, safe compact controllers
Phasing out and discontinuation

Last Order: 30.09.2024 Key data


Last Delivery: 31.12.2024 Item number: 772000 - 772036
Repair guarantee: in accordance with the Pilz General Terms and Designation: PNOZmulti Mini incl. extensions
Conditions until at least 2 years after product discontinuation Number of variants: 14

PNOZ m B0.1
Successor device with modern architecture
The difference lies in the connection on the right-hand side
(max. 1 x expansion module PNOZmulti 2)
PNOZsigma extensions cannot be plugged in directly
OR

PNOZ m B0

PNOZmulti Mini Difference to PNOZ m B0.1 - up to 6 expansion modules


possible on the right-hand side

April 2024 Generation change PNOZmulti 10


www.pilz.com

© Pilz GmbH & Co. KG 2024

CECE®, CHRE®, CMSE®, INDUSTRIAL PI®, Leansafe®, Myzel®, PAS4000®, PAScal®, PASconfig®, Pilz®, PIT®, PMCprimo®, PMCprotego®, PMCtendo®, PMD®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, THE SPIRIT OF SAFETY® sind in einigen Ländern amtlich registrierte und
geschützte Marken der Pilz GmbH & Co. KG. Wir weisen darauf hin, dass die Produkteigenschaften je nach Stand und Ausstattungsumfang von den Angaben in diesem Dokument abweichen können. Für die Aktualität, Richtigkeit und Vollständigkeit der in Text und Bild dargestellten Informationen übernehmen wir keine Haftung.
Bitte nehmen Sie bei Rückfragen Kontakt zu unserem Technischen Support auf.
Generation
April 2024 change PNOZmulti 12

You might also like