0% found this document useful (0 votes)
78 views1 page

Thyristor Trigger Module

The TRK Thyristor Trigger Module supports various analog input types and offers control methods including zero cross and phase shift outputs. It is designed for both resistive and inductive loads with a capacity of up to 1000 A SCR, featuring a 4-digit display for programming and monitoring. Additional functionalities include soft-start, power and current limit settings, and strong anti-interference capabilities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views1 page

Thyristor Trigger Module

The TRK Thyristor Trigger Module supports various analog input types and offers control methods including zero cross and phase shift outputs. It is designed for both resistive and inductive loads with a capacity of up to 1000 A SCR, featuring a 4-digit display for programming and monitoring. Additional functionalities include soft-start, power and current limit settings, and strong anti-interference capabilities.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

TRK Thyristor

Trigger
Module
www.swastikautomation.com

INPUT TYPE Input Support Several Analag Input ( 0 - 10 V, 0 - 5 V,1 - 5 V, 0 - 20 mA, 4 - 20 mA )


External Support External Potentiometer for Manual Function
CONTROL METHOD
Control Zero Cross Output, Phase Shift Output ( with Midline / Without Midline )
Phase Shift < 175 degree
Mode Combine Trigger Mode of Pulse and Optocoupler
OUTPUTS
Load Suitable for Resistive and Inductive Load
Load Capacity Suitable up to 1000 A SCR
Wiring Support Several Mode of Wiring ( Star with Midline, Star Without Midline, Triangle Wiring )
Anti-Interference Strong Anti-Interference Function and Pass 1800 V Common-mode and differential Mode Experiment

DISPLAY Display / Keyboard 4 Digit Display with 4 Keys to Program


KEYBOARD Indication Powen Indication / RUN Indication / On- Line Display for Running Output / Error Message Indication
Mounting Din Rail Mounting
Cautoni - Swastik

Other Feature
Protection Stop-Phase Protection
Soft -Start Support Soft Start Function with Adjustable Time Limit
Function Support Power Limit and Current Limit Function
Programmable Function Min. / Max. Output Can be Limit through Programming
Power Supply
Supply AC 85~ 265 V, 50 Hz
Ambienent Temperature 0*C ~ 50 *C

Ordering Information
TRK - 1 - A - 2 3 4 5

1 Output :- 1: SINGLE PHASE 3 : THREE PHASE Table : A 0 : Zero Cross Output ( Resistive Load )
1 : Phase Shift Output ( Resistive Load )
2 Input :- 0 : 0 - 20 mA 1 : 0 - 10 mA 2 : 4 - 20 mA 2 : Phase Shift Output ( Inductive Load )
3:0-5V 4 : 0 - 10 V 5:1-5V
3 Control Method :- Single Phase : check Table - A Table : B 0 : Three Phase Phase Shift ( Without Midline )
Three Phase : check Table - B
1 : Three Phase Zero Cross ( Without Midline )
4 Ext. Potentiometer :- 0 : Not Support 1 : Support 2 : Three Phase Phase Shift ( with Midline )
3 : Three Phase Zero Cross ( with Midline )
5 Display Method :- 0: Not Support 1 : Support
4 : Three Phase Half Control Phase Shift ( Without Midline)

You might also like