IEC62619-Test Report
IEC62619-Test Report
TEST REPORT
IEC 62619
Secondary cells and batteries containing alkaline or other non-acid
electrolytes – Safety requirements for secondary lithium cells and
batteries, for use in industrial applications
Responsible Testing Laboratory (as applicable), testing procedure and testing location(s):
Summary of testing:
Tests performed (name of test, test clause and Testing location: (CBTL, SPTL, CTF,
date test performed): Subcontractor)
7.2.2 Impact test (cell) Shanghai Truron Testing Technology Co., Ltd.
7.2.3.2 Whole drop test (cell)
7.2.4 Thermal abuse test (cell) Address: Floor 1 and 2 Building 1, No. 685,
7.3.2 Internal short-circuit test (cell) Huishan Road, Shanghai, China
7.2.1 External short-circuit test (cell) Address: NO.5 Workshop 4450 Shuangzhu Road
Jiadin, Shanghai, 201807, China
7.2.5 Overcharge test (cell)
7.2.6 Forced discharge test (cell)
EU group*
No decision rule is specified by the IEC standard, when comparing the measurement result with the
applicable limit according to the specification in that standard. The decisions on conformity are made
without applying the measurement uncertainty (“simple acceptance” decision rule, previously known as
“accuracy method”).
Other: … (to be specified, for example when required by the standard or client, or if national
accreditation requirements apply)
+ 100Ah 3.2Vdc -
50160118
XXX2174DDDDD
Rechargeable Li-ion Cell
IFpP51/161/119/M/-30+60/95
Guangdong Highpower New Energy Technology
Co., Ltd
Or
+ 100Ah 3.2Vdc -
50160118-100Ah
XXX2174DDDDD
Rechargeable Li-ion Cell
IFpP51/161/119/M/-30+60/95
Guangdong Highpower New Energy Technology
Co., Ltd
Or The marking of LFP100L and LFP100 were same as above except the model name.
Note: The purchaser and the manufacturer get arrangement, marking on cell was not required or the
missing information is provided by instruction or other way because the cell was for build-in use only.
General remarks:
"(See Enclosure #)" refers to additional information appended to the report.
"(See appended table)" refers to a table appended to the report.
This Test Report Form contains requirements according to IEC/ISO …... Standard dated ….. and
includes Corrigendum dated …….
(Note: The above text maybe removed if not applicable)
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate Yes
includes more than one factory location and a Not applicable
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ............................................................... :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) .......................... : Same as Applicant
- Rechargeable Lithium-ion Cell, all positive electrode, negative electrode and separator are covered by Al
case and insulation materials.
- Maximum charge current of 100A, end of discharging voltage is 2.5V
- Upper limit charging voltage is 3.65V
- IFpP51/161/119/M/-30+60/95 is identical to model 50160118, 50160118-100Ah, LFP100L, LFP100
except for model designation.
Reissue 1:
This test report was deemed to reissue, due to the following changes according to customer’s request:
1. Add two alternative model: LFP100L, LFP100.
This report is a reissue of CBTR Ref. No.: A2-4790779795-001, Issued Date: 2023-05-05; CB Test
Certificate Ref. No. DK-140653-UL, Issued Date: 2023-05-06 by UL Solutions (Demko), CB Certificate
Ref. No. DK-140653-A1-UL (correction), Issued Date: 2023-05-06 by UL Solutions (Demko).
Based on the previously conducted testing and the review of product construction, no test was deemed
necessary.
Reissue 2:
This test report was deemed to reissue, due to the following changes according to customer’s request:
1. Change the charge temperature from “0~55°C” to “0~65°C”, and discharge temperature from “-
20~60°C” to “-30~65°C”;
2. Change the cell designation “IFpP50/160/118/M/-20+60/95” to “IFpP50/160/118/M/-30+60/95”.
This report is a reissue of CBTR Ref. No.: A2-4790882026-001, Issued Date: 2023-06-16; CB Test
Certificate Ref. No. DK-142387-UL, Issued Date: 2023-06-26 by UL Solutions (Demko).
Based on the previously conducted testing and the review of product construction, no test was deemed
necessary.
Reissue 3:
This test report was deemed to reissue, due to the following changes according to customer’s request:
1. Update the view of cell in Enclosure ID 01-01, 01-02, due to the change of QR code.
2. Add dimensions tolerance of cell in Enclosure ID 02, 03, and change “FpP50/160/118/M/-30+60/95”
to “IFpP51/161/119/M/-30+60/95”.
3. Update the diagram in Enclosure ID 03, 04.
4. Add dimensions tolerance for components information in TABLE: Critical components information.
This report is a reissue of CBTR Ref. No.: A2-4790964411-001, Issued Date: 2023-08-10; CB Test
Certificate Ref. No. DK-144109-UL, Issued Date: 2023-08-14 by UL Solutions (Demko).
Based on the previously conducted testing and the review of product construction, no test was deemed
necessary.
9 EMC N/A
Battery system fulfil EMC requirements of the end- N/A
device application .................................................... :
Results:
A – No fire or explosion
B – Fire
C – Explosion
D – Test concluded when 50 mV voltage drop occurred prior to reaching force limit
E – Test concluded when 800/400 N pressure was reached and 50 mV voltage drop was not achieved
F – Test was concluded when fire or explosion occurred
G – Other (Please explain): __
Method of cell failure 1) Location of target cell Area for fire protection (m2)
Supplementary information:
1) Cell can be failed through laser exposure, applied heat, overcharge, nail penetration or combinations of
these failures or other acceptable methods. See supporting documentation for details on cell failure
method
2) If the battery system has no outer covering, the manufacturer is required to specify the area for fire
protection.
Results:
A – No fire external to DUT enclosure or area for fire protection or no battery case rupture
B – Fire external to DUT enclosure or area for fire protection
C – Explosion
D – Battery case rupture
E – Other (Please explain): __
Supplementary information:
1) The exceeded voltage can be applied to only a part of the system such as the cell(s) in the battery
system per Figure 6 of IEC 62619, if it is difficult to do it in using the whole battery system.
Results:
A – No Fire or Explosion
B – Fire
C – Explosion
D – The voltage of the measured cells or cell blocks did not exceed the upper limit charging voltage
E – The voltage of the measured cells or cell blocks did exceed the upper limit charging voltage
F – All function of battery system did operate as intended during the test.
G – All function of battery system did not operate as intended during the test.
H – Other (Please explain): ___
Supplementary information:
Results:
A – No fire or Explosion
B – Fire
C – Explosion
D – Overcurrent sensing function of BMU did operate and then charging stopped
E – Overcurrent sensing function of BMU did not operate and then charging stopped
F – All function of battery system did operate as intended during the test.
G – All function of battery system did not operate as intended during the test.
H – Other (Please explain): ____
Supplementary information:
Results:
A – No fire or Explosion
B – Fire
C – Explosion
D – Temperature sensing function of BMU did operate and then charging stopped
E – Temperature sensing function of BMU did not operate and then charging stopped
F – All function of battery system did operate as intended during the test.
G – All function of battery system did not operate as intended during the test.
H – Other (Please explain): ____
Sample No. EMC Test Battery EMC Test Level/ Compliance Results
Item Condition Parameters Criteria
Supplementary information:
Battery Condition During EMC test
1 – In Operation Mode, [ ] Supplied at ____, [ ] Load at____
2 – In non-operation Mode, Battery state of charge (SOC) before test at around____
ENCLOSURE
Supplement ID Description
01-01 Front view
01-02 Top view
02 Specification
03 Outline Dimension
04 Package requirement
05 Date of manufacture
06-01 ISO 9001 certification
06-02 ISO 9001 certification
07 The appearance of the internal short-circuit location
Page 2 of 10 Report No. A2-4790989963-001
ID 01-01
Page 3 of 10 Report No. A2-4790989963-001
ID 01-02
Page 4 of 10 Report No. A2-4790989963-001
ID 02
Item Specification
Product name Rechargeable Lithium Cell
Guangdong Highpower New Energy
Manufacturer
Technology Co., Ltd.
50160118, 50160118-100Ah, LFP100L,
Model name
LFP100
Cell Type LiFePO4
PTC or other current/ thermal
N/A
protection
Rated Capacity 100Ah
Standard Charging Current 50A
Standard Full Charging Voltage 3.65V
End of Charging Current 5A
Maximum Charging Current 100A
Standard Discharging Current 50A
Maximum Discharging Current 100A
End Point Voltage 2.5V
Discharge Temperature range -30~65 C
Charge temperature range 0 ~ 65 C
Upper limit charging voltage 3.65V
Weight 2.0±0.15 kg
Dimensions 50.0±0.5×160.2±0.5×118.3±0.5 mm
Page 5 of 10 Report No. A2-4790989963-001
ID 03
Dimensions 50.0±0.5*160.2±0.5*118.3±0.5mm
Page 6 of 10 Report No. A2-4790989963-001
ID 04
Page 7 of 10 Report No. A2-4790989963-001
ID 05
Page 8 of 10 Report No. A2-4790989963-001
ID 06-01
Page 9 of 10 Report No. A2-4790989963-001
ID 06-02
Page 10 of 10 Report No. A2-4790989963-001
ID 07