Cim256 10 GB

The document is an instruction and user manual for the CIM-256/10 irrigation motor pumpset control unit, which features GSM telephone notification and command capabilities. It provides details on the unit's functions, including alarm notifications, control of pump operations, and monitoring of various engine parameters. Additionally, it outlines installation procedures, emergency stop functionality, and programming for SMS alerts and pump management.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views12 pages

Cim256 10 GB

The document is an instruction and user manual for the CIM-256/10 irrigation motor pumpset control unit, which features GSM telephone notification and command capabilities. It provides details on the unit's functions, including alarm notifications, control of pump operations, and monitoring of various engine parameters. Additionally, it outlines installation procedures, emergency stop functionality, and programming for SMS alerts and pump management.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

UNIT FOR CONTROL AND PROTECTION

OF IRRIGATION MOTOR PUMPSET


INSTRUCTION AND USER MANUAL

TYPE CIM-256/10
COMPLETE OF GSM TELEPHONE
ANNUNCIATOR AND
COMMAND SYSTEM
• Notifies up to 3 users via SMS message
when the motor pump is on the alarm
• Allows you to control the stopping and
restarting of the pump
• Allows you to view the status of the
main tools of the control unit
• Comes complete with high-gain antenna
• By simply starting, it automatically
controls the motor pump
• Pump water electronic pressure gauge
MOUNTING AT PANEL
• Digital pump water pressure gauge
• Assembly also on the machine
and in the open air.
MADE TO:
PROTECT DISPLAY
motor pump sets by stopping them on the panel the functions of:
in the event of:
• hour-meter
• low oil pressure
• oil pressure gauge
• over-temperature
• water or oil thermometer
• belt breakage
• tachometer
• minimum fuel level
• pump water pressure gauge
• low coolant level
• timer
• low pump water pressure
• fuel level gauge
• pump water overpressure
• pump protection exclusion
• A1 available
• battery and oil lights
• low fuel pressure
• protections intervention
• emergency stop

PARMA ® ITALY

Tel. +39 0521/772021 Fax +39 0521/270218


GB CIM-256/10 E-mail: [email protected] - HTTP://www.elcos.it 1
BRIEF INSTRUCTIONS
After starting, the motor pump protects itself automatically

PUMP WATER BAR ENGINE WATER OR OIL ENGINE OIL PRESSURE FIELD SIGNAL STRENGTH
MOTOR PUMP OPERATING
PRESSURE IS DISPLAYED TEMPERATURE IS IS DISPLAYED
SPEED IS DISPLAYED
DISPLAYED SMS MESSAGE BEING
A1 AVAILABLE RECEIVED OR SENT

THE FUEL LEVEL SYSTEM ERROR.


IS DISPLAYED MISSING SIMCARD.
PROCEDURES FOR DISABLING
THE PIN CODE, NOT REGULAR
ACCUMULATED CUMULATIVE ALARM
OPERATION HOURS
ARE DISPLAYED
LOW FUEL PRESSURE
PRESS IF YOU WANT
TO SET WORKING PRESS TO SELECT THE
TIME ( UP TO 96 % BAR DISPLAYED FUNCTION,
HOURS) °C ~
~ ~
~
EACH TIME IT IS
STOP
STOP
RPM
PRESSED, THE INSTRU-
MENT INDICATED BY THE
h
DISPLAY CHANGES.
EMERGENCY STOP
! A1 CELL

STARTUP FAILURE ~
~ ~
~ NO_CELL WATER PRESSURE IS
ALARM REGULAR
PRESS TO ADJUST PRESS UNTIL THE 2
WATER PUMP SIGNS START FLASHING
ELECTRONIC ~
~ ~
~
TO EXCLUDE PUMP
PRESSURE SWITCH PROTECTION.
BAR M P TO RE-ACTIVATE
ENGINE PROTECTION, PRESS
PROTECTIONS AGAIN UNTIL THEY
ARE ACTIVE SWITCH OFF.

THE BATTERY IS
NOT CHARGING
PUMP PROTECTION
LOW ENGINE IS ACTIVE
OIL PRESSURE

0 AUT.
AVV.
STOPPAGE DUE TO LOW
FUEL LEVEL
STOPPAGE DUE TO LOW STOPPAGE DUE TO INSUFFICIENT
COOLANT LEVEL ENGINE OIL PRESSURE

STOPPAGE DUE TO LACK OF BATTERY


CHARGING (BELT BREAKAGE) STOPPAGE
DUE TO LOW LOW PRESS.
STOPPAGE DUE TO HIGH PRESSURE
ENGINE TEMPERATURE ~
~ ~
~ OR
PUMP WATER OVERPRESS.
OVERPRESSURE
OR
ELECTRONIC
PRESSURE GAUGE DISCONN'ED
(TRANSMITTER)
INTERRUPTED.
IN THIS CASE,
THE ANOMALY IS
HIGHLIGHTED BY
THE FLASHING
WARNING LIGHT.

START KEY
0
- OFF
- STOPPAGE IN ALL OPERATING CONDITIONS
- RESTORE PROTECTIONS, CANCEL PUMP PROTECTION EXCLUSION AND TIMER,
DEACTIVATE INSTRUMENTS.
AUT.
- CONTROL PANEL SUPPLY
- TURNS ALL THE LIGHTS ON FOR 2 SECONDS ( EFFICIENCY
CHECK )
AVV. - PRESSURE SWITCH ADJUSTING (SEE PAGE 3)

- MOTOR PUMP START UP

2 GB CIM-256/10
ADJUSTING THE PUMP WATER ELECTRONIC PRESSURE GAUGE (TRANSMITTER)
It controls the pressure of the system, replacing the conventional pressure switch.
PUMP PROTECTION
No adjusting is required P
The protection of the pump is enabled when the PUMP PROTECTION ACTIVE information comes on, after the water
pressure has been steady for 2 consecutive minutes and in any case after 10 minutes from starting of the engine.
Intervention of the protection occurs 5 seconds after the pressure goes up or down by two bars, stops the engine and is shown on
the display:
It is possibile to change the two bars of the pressure
OVERPRESS.
lowering (low pressure) by using the key
Pump water BAR
overpressure
This change is cancelled when
or the engine stops.
INSUFF. PRESS.
LOW PRESS.
Low OVERPRESSURE remains set to two bars, this value is
pressure added to the working pressure (for example, working
(low pressure) pressure 9 bar overpressure 11 bar)

WORKING PRESSURE BAR

PRESSOSTAT Press to
Press to adjust select the
BAR BAR 7
the value of pump water
low pressure pressure gauge
(PRESSOSTAT)

TIMER
Enabled with key on “AUT”, it makes it possible, if necessary, to have the motor pump work for an adjustable length of time (96 hours maximum),
at the end of which it stops and the WORK TIME OVER sign lights up on the display.
STOP

The work time is set by pressing the push-button ( lights up) until the desired value appears on the
DISPLAY .

On releasing the push-button, the timer automatically starts working, continously displaying the remaining work time.

CANCELLING THE SET TIME


To zeroing the set time there are two methods:
- keep the push-button pressed until it reaches zero.

- by turning the starter key onto "ZERO" (the engine pump will stop).

PUMP PROTECTION EXCLUSION


(ENABLED ONLY WITH RUNNING ENGINE )
The push-button excludes pump protection:
- exclusion is obtained by keeping it pressed for at least 3 consecutive seconds; the function is indicated by the two intermittent lights .

- this exclusion is cancelled by pressing the push-button again or by turning the start key onto "ZERO".

OIL AND BATTERY INDICATOR LIGHTS


Lit up with key on "AUT", they switch off with the engine running and regular oil pressure and battery charge system.

ENGINE PROTECTIONS
The engine protections are enabled when the ENGINE PROTECTIONS ACTIVE light M comes on (20 seconds after the end of starting impulse
and however 1 minute after positioning the key on “AUT”).
Interventions of the protection probes (fitted on the engine), indicated by the relevant lights, stop the engine, they are memorised and can be split into
two groups.
Delayed by 2 seconds for: Delayed by 5 seconds for:
- OIL PRESSURE SWITCH - A1
- BATTERY CHARGE ALTERNATOR
- OVERTEMPERATURE (ALTERNATOR BELT BREAKAGE)
SWITCH ~
~ ~
~
- FUEL LEVEL SWITCH
- Fuel reserve flashing signal: 20% fuel reserve
(T) (WITHOUT ENGINE STOP)
- Signal always on: stop for minimum fuel level (W)

- PROBE FOR COOLANT LEVEL

- LOW FUEL PRESSURE

GB CIM-256/10 3
OPERATION
ONTROLLING THE CONNECTION OF THE PUMP WATER
ELECTRONIC PRESSURE GAUGE (Transmitter)
Turning the key to the AUT position stops the electronic pressure gauge.

Control is activated 1 minute after the completion of the starting pulse.


INTERROTTO
Intervention is highlighted by the relevant indicators flashing warning light
and stops the motor pump after 2 seconds.

To exclude intervention, press the push-button PUMP PROTECTION EXCLUSION.

PUMP PROTECTION
The pump protection is enabled with the switching on of the ACTIVE PUMP PROTECTION (after 2 consecutive
minutes of stable water pressure, indicated by the visual signal REGULAR PUMP PRESSURE and, in any
case, 10 minutes after the start of the motor pump)

The intervention of the protection (5 seconds after the increase or decrease of the pressure) stops the engine and
is indicated by the visual signal for LOW PUMP WATER PRESSURE or
WATER PUMP OVERPRESSURE .
RESET : is obtained by turning the start key onto "ZERO".
STOPPING THE MOTOR PUMP
The control unit shuts down the engine in five conditions:
- turning the starter key onto "ZERO”
- protection intervention
- timer intervention at the end of the work period
- giving the command from a cell phone
- through intervention of the external emergency.
The unit adapts to two different stop systems
- by working the ELECTROMAGNET for 20 seconds which pulls the STOP lever
- by cutting off power to the SOLENOID VALVE shutting off the flow of fuel.
ANOMALY REPORT
Simultaneously press four buttons (for at least 5 seconds): the word HISTORICAL appears on the display.
Release the buttons, and for 10 seconds the display will show the most recent anomaly that caused the pump to stop.
AUTOMATIC RESTART WITH CELL PHONE
It is not possible to restart the motor pump with the key in the 'zero' position.
Restarting is possible after the pump has been stopped by cell phone or timer.
Before the start, the internal annunciator sounds for 8 seconds, and, after a 3 second pause, startup begins. To
facilitate startup, a special circuit emits a series of four, 5-second pulses, with a 5-second delay between each pulse.

START UP FAILURE
Blocks the startup cycle if the pump has not started up after the fourth pulse.
GENERAL ALARM
This can be obtained by fitting on the outside an optical and/or acoustic signaller to be connected to the RED/GREEN
wire. It is activated on protection intervention.
EMERGENCY STOP
It can be obtained in all functioning conditions, mounting one or more release-type buttons. It is indicated by the
visual signal ! and enables the general alarm.
INSTRUMENT SELECTION
The control unit comprises six instruments:
h HOUR METER - Total hours of operation (with the engine running the signal pulsates, to
indicate the correct functioning of the HOUR-METER).
INSTRUMENTS WHICH CAN BE SELECTED IN SEQUENCE BY PRESSING THE BUTTON
Each time it is pressed, IT SHOWS the next instrument. WHEN THE TIMER IS set, the duration of the display of
the instrument is limited to 30 seconds from the activating of the button; the TIMER then reappears.
bar
C
- PRESSURE GAUGE - Engine oil pressure
- THERMOMETER - Engine oil and water temperature
} TRANSMITTERS
ON REQUEST
FITTED ON ENGINE

RMP - TACHOMETER - Speed of motor pump


BAR - PRESSURE GAUGE - Pump water pressure
% - INDICATOR - Fuel level percentage
4 GB CIM-256/10
GSM TELEPHONE ANNUNCIATOR AND
COMMAND SYSTEM GSM
(Modem integrated into control unit)

FUNCTIONS AND PROGRAMMING


Warns with an SMS message that the motor pump is in alarm mode.

• Programming of phone numbers to notify when the motor pump is in alarm mode.

• Possibility of displaying the status of the motor pump.

• Possibility of switching off the pump protection.

• Setting of minutes of running.


• Possibility of commanding stopping and restarting of the motor pump.

To insert the SIM CARD and program the telephone warning device
remove the cover of the control unit.
GREEN GREEN
CIM-256/10 CEM-256/10
LEDs LEDs
MODEM
CONTROL UNIT

MODEM
CONTROL UNIT

Telephone number
The telephone number is supplied by the provider once the contract has been signed. This is the number you should dial
from your cell phone when you want to interact with the modem of the control unit.

Procedure for disabling the PIN code


Once the SIM card has been purchased from a telephone provider on any contract, the PIN needs to be disabled. To do this, it is
necessary to insert the SIM in a normal private-use cell phone, then enter the PIN supplied by the provider. Browse through the
cell phone menu to locate the procedure for disabling the PIN. Carry out the disabling procedure and check that, on turning the
phone on again, the PIN is not requested.
Turn off the phone and take out the SIM card. Ensure that the motor pump is not running (the display will be blank and the
green leds off), then insert the SIM in the slot provided.

Activation
To ensure that the area around the unit is being reached by the field signal, check the graphical indicator
on the display. If necessary, position the unit's internal antenna outside the unit, at the point where the signal
is strongest.
The programmings, the controls
AUT.
and the display of motor pump status are active with the starter key of the control unit in
automatic position .
Precautions
- Position the antenna vertically using its magnetic base.
- Do not connect an extension cable to the antenna cable.

GB CIM-256/10 5
INSTALLING THE CONTROL UNIT
COOLANT LEVEL PROBE
FOR RADIATORS WITH FOR RADIATORS WITH
PLASTIC EXPANSION TANK METAL EXPANSION TANK

WARNING

!
IF THE FUNCTION
- LOW COOLING
LIQUID LEVEL
IS NOT USED:
CONNECT YELLOW/
ORANGE WIRE
TO EARTH
155 155
ROD YELLOW/
SCREW ORANGE
ELECTRODES ELECTRODE

ANTENNA
DO NOT CLOSE TO REPLACE THE FUSES
IN A METALLIC AND INSERT THE SIM CARD,
CONTAINER REMOVE THE COVER
FROM THE CONTROL UNIT 1/4” 3/8”
D GAS GAS
PUMP WATER PRESSURE TRANSMITTER CABLE

A STOP SYSTEM SET UP


The control unit
has been designed To stop with the SOLENOID VALVE
to control stopping with an E/B
ROW cut and isolate the BLUE/BROWN lead
N

BLU
ELECTROMAGNET
SET UP BL
AC
• WATER OR OIL To view the water/oil THERMOMETER and the oil pressure GAUGE,
B
K
/VIOL

THERMOMETER ET
connect the transmitters to the respective wires of the unit,
• OIL PRESSURE GAUGE then CUT and isolate the BLACK/VIOLET wire
CONNECTION OF
EMERGENCY BUTTON CONNECTOR C STOP SYSTEMS
EXCITED IN STOP MODE EXCITED WHILE
RUNNING
YELLOW

YELLOW
3 1 YELLOW
2
1 4
3 ORANGE/WHITE WARNING! :
4 IT IS NOT 85 30 85 30
2 POSSIBLE
ORANGE/WHITE
ORANGE/WHITE
YELLOW
YELLOW

BEFORE CONNECTING THE EMERGENCY


BUTTON REMOVE THE CONNECTOR TO MOUNT
WITH THE JUMPERS THE 86 87 86 87
EMERGENCY
STOP BUTTON
SOLENOID
ON A STOP
ORANGE/WHITE
YELLOW
4 C SYSTEM WITH
to close
the fuel
ELECTRO-
MAGNETS
3 2 7
2

ELECTROMAGNET
1 to activate the
YELLOW engine STOP lever.
ORANGE/WHITE

TACHOMETER ADJUSTMENT
Run the engine
at a costant and
known rpm
value RPM Select the instrument
(for example by TACHOMETER,
means of keep the button
a portable depressed for at
revolution counter) least 5 seconds and simultaneously press BAR
increase or decrease
until the correct reading appears on the display.
Release the buttons and wait until OK appears on the display.
6 GB CIM-256/10
INSTALLING THE CONTROL UNIT
WIRING DIAGRAM
TO CONNECT THE EMERGENCY BUTTON
see page 6 (connector C).
FROM 15/54 OF START KEY,
3A MAX
USABLE FOR HEADLIGHT 157
OR AUXILIARY CONNECTOR CONNECTOR 3A MAX
YELLOW/ORANGE RED/GREEN
11 10
CONNECTOR
9 8 7 D 6 5 4

CABLE 2,5m
ORANGE/BROWN
3
6 5 4 2 1 3 2 1

BLACK/BLUE
3 2 1 ORANGE/

WHITE/VIOLET
155 BLUE
T INDICATOR
BROWN (ONLY FOR PERMANENT MAG.) W RESERVE

SKY/BLUE
INSULATE
GREY
WHITE/RED

A1 POSSIBLE

ORANGE
YELLOW

CABLES NOT
GREEN

WHITE

218 191
CONNECTED
112
4 WHITE/GREEN
40A MAX 18
BLACK 173
30
RED
26/28 + BATTERY 50
3A MAX

2/7 97
40
3

41

STOP
SYSTEMS
SEE PAGE 4

CHARGE BATTERY ALTERNATOR: ACCESSORIES AVAILABLE ON REQUEST


(2/7) ELECTROMAGNET OR SOLENOID VALVE
PRE-EXCITATION
(3) OIL PRESSURE SWITCH
W WHITE/RED (4) THERMOSTAT
B+ + BATTERY (18) FUEL FLOAT FOR INDICATOR AND RESERVE
D+ GREEN (97) OIL PRESSURE TRANSMITTER
28
(112) TEMPERATURE TRANSMITTER

DO NOT USE BROWN (155) COOLANT LEVEL PROBE


(173) PUMP WATER PRESSURE TRANSMITTER (SUPPLIED)
(26) PERMANENT MAGNETS CHARGE ALTERNATOR
PERMANENT MAGNETS (27) BATTERY CHARGE ALTERNATOR REGULATOR
YELLOW WHITE/RED
RED (28) PRE-EXCITATION CHARGE ALTERNATOR
YELLOW
+ BATTERY (40) STARTING MOTOR
R + LE
(41) BATTERY
GREEN
27 (157) GENERALALARM LIGHT
26
GRGB L C
+ BROWN (191) A1 AVAILABLE FOR PROTECTION PROBE

27 (218) FUEL PRESSURE SENSOR

CONNECTION SYSTEM SELECT LANGUAGE The language set up is ITALIAN; the


FOR EXTRACTING THE languages that can be selected are: ENGLISH, FRENCH, GERMAN,
W TERMINAL IN SPANISH and PORTUGUESE.
P R E - E X C I TAT I O N TO TACHOMETER
(WHITE/RED WIRE) ON Move DIP ON Move DIP
B AT T E RY C H A R G E
ALTERNATORS. 1 switch 1 to ON 1 switch 1 to OFF

ITALIANO ENGLISH
To diode bridge
(BOSCH, MARELLI,
LUCAS, ECC...)
} (inside alternator)
Press to select Press and wait for
the desired language OK to be written
GB CIM-256/10 7
Notifies via SMS message when the motor pump annunciator has been activated
Should the unit indicate there is a problem with the motor pump, a message is sent to the first number. If there is no
answer, 10 minutes later a message is sent to the second number, and so on. Three numbers can be set in total. The
process continues for 4 times if none of the 3 users contacted sends an SMS reply to the unit using the phrase OK.
Any subsequent problems with the pump result in the SMS notification process being started again.
N.B.: It is possible that, once one of the users has sent an OK message to the unit, another error message may be sent
to the second user. This is due to delays caused by traffic on the telephone network and is outwith the control of the unit.

When the SMS TO ALL PHONES INCLUDED function is used (factory setting) the SMS fault messages are sent
only to the telephones programmed in the list of telephone numbers of the control unit. For example: an operator who
starts the motor pump from their mobile phone, and does not have their telephone number programmed in the list of
telephone numbers, will NOT receive the SMS message in the event of a fault. But it will be received by the telephone
with its number programmed in the control unit following the procedure described later.

Programming the cell phone numbers of the users who are to be notified
when the motor pump alarm has been set off.

AUT.
• DO NOT PROGRAM DURING STOPPING.
• PROGRAM WITH THE STARTER KEY OF THE CONTROL UNIT IN AUTOMATIC POSITION .

ON Move DIP
4 switch 4 to ON
(Inside the control unit)

WRITE THE MOBILE


CHOICE OF SUBSCRIBER PHONE NUMBER CONFIRMATION

PHONE ON
NUMBER
4
MOBILE
PHONE Move DIP 0123456789
0123456789
NUMBER switch 4 to OFF
CELL
CELL CELL

Press and
wait for
Push to view
OK to be
the first, Enter the number of written
second the cell phone to
or third which the unit is to
subscriber. send an SMS
CELL 0123456789
HOW TO ENTER
Press to select the number, Press to
release the button for at least BAR cancel
1 second and the letter or
number will remain on the
display.

CELL

TO CONFIRM RECEPTION OF THE SMS WARNING MESSAGE AND STOP THE SENDING OF SUBSEQUENT
MESSAGES, SEND A MESSAGE FROM YOUR CELL PHONE USING THE PHRASE OK OR THE CODE 002

After confirmation,
the display will show NOTIFIED
CELL

8 GB CIM-256/10
HOW TO VIEW THE STATUS OF THE MOTOR PUMP

To request an On your cell phone,


update on the it is possible to view
status of the
motor pump, - hour-timer
enter the
code 001 into
- oil pressure gauge
- water or oil thermometer }On request
your cell phone - tachometer
and send it by - pump water pressure gauge
SMS to the unit. - fuel level
- timer
(displays the working time remaining
before the motor pump is set to stop)
- pump protection exclusion

! Warning:
We advise sending the STOP-005 or 010 (pump protection switch off) command to the control unit only after making sure
the control unit starter key is in the AUT position. To check this condition, send the control unit the 001 status command
and wait for the reply. If no reply is received within a few minutes DO NOT send the stop or pump protection switch off
commands.

POSSIBILITY OF SWITCHING OFF THE PUMP PROTECTION


Reply message from
control unit to
To switch off the mobile phone:
pump protection, key
INTERMITTENT
in 010 on the mobile SIGNALS
phone
PUMP PROTECTION
After the switch ON
off command,
the following is displayed: CELL

SIGNALS
OFF PUMP PROTECTION
OFF
To delete this switching After the command
off, key in 011 on the to delete switching off,

}
WATER PRES. 6,8 Bar
Example

mobile phone the following is displayed: CELL

PRESSURE GAUGE 4,5 Bar

TIMER 10:15

GB CIM-256/10 9
SETTING THE MINUTES OF RUNNING
(TIMER) WORKING TIME
(MINUTI)
To set the the minutes
(minimum 1’ max 1440’) Reply message from
of running of the motor control unit to
pump after the mobile phone:
command: After the
command, the
500#...... screen displays: OK if the setting
Minutes CELL
is correct.
of running
example: ERROR if the setting
HOURS OF OPERATION
is not correct.
500#120
(2 hours of
running)
Wrong examples

500 space 120


500 = 120
spaces 500 # 120
500 or 120
500 # 1441

POSSIBILITY OF COMMANDING STOPPING AND RESTARTING


OF THE MOTOR PUMP
It is only possible to stop and restart the motor pump using a single cell phone (the one that corresponds to the first
number programmed into the unit). To do so, enter and send the stop code on your cell phone.
Reply message from
control unit to
To stop or restart the mobile phone:
STOP
unit via your cell
phone, enter After the STOP
The motor pump
the code STOP or command, the
is not running
the code 005 screen displays: MOTOR PUMP

CELL

WATER PRESSURE

After the START


command, the START
the code START The motor pump
screen displays:
or the code 008 has started up

CELL

HOURS OF OPERATION

WATER PRESSURE

Restart with pump


protection INTERMITTENT The motor pump
switched off.
SIGNALS START has started up.
After the switch PUMP PROTECTION
To activate this off command, OFF
function, key in the following
009 on the is displayed: CELL

mobile phone
HOURS OF OPERATION

SIGNALS PUMP PROTECTION


After the OFF ON
command
To delete the to delete
Example

}
WATER PRES. 6,8 Bar
switching off, switching off,
key in 011 on the the following PRESSURE GAUGE4,5 Bar
mobile phone is displayed:
TIMER TIMER

10 GB CIM-256/10
®
S.r.l. UNIT FOR CONTROL AND PROTECTION
Via Arandora Star, 28/a-43122 PARMA ITALIA
Tel. +39 0521/772021
Fax +39 0521/270218 OF IRRIGATION MOTOR PUMPSET
E-mail: [email protected]
HTTP://www.elcos.it
TYPE CIM-256/10

Only for starting and surveillance of the diesel motor pump and stops it if there are anomalies in
the parts controlled by probes.
It has been designed to be installed also on the machine.

NOTICES

! Warning:
adhere closely to the following advice:
- Always install under other equipment which produces or spreads heat.
- Always follow the Wiring Diagram on pages 6-7 when making connections.
- Check that the line loading and the consumption of the connected equipment are compatible
with the technical characteristics on page 12.
- All technical interventions must be performed with the engine stationary and terminal 50 of
the starter motor disconnected.
- Never use a battery charger for the emergency start-up, this could damage the control unit.
- To protect the safety of persons and the equipment, before connecting an external battery
charger, disconnect the electrical plant terminals from the battery poles.
- Never disconnect the battery terminals with the engine running.

THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING


CONDITIONS:
- Where the environmental temperature is outside the limits indicated in the Technical Data on
page 12.
- Where there are high levels or heat from radiation caused by the sun, ovens or the like.
- Where there is the risk of fire or explosions.
- Where the panel can receive strong vibrations or knocks.

ELECTROMAGNETIC COMPATIBILITY
This control unit functions correctly only if inserted in plants which conform with the CE marking
standards; it meets the exemption requirements of the standard EN61326-1 but it cannot be
excluded that malfunctions could occur in extreme cases due to particular situations.
The installer has the task of checking that the disturbance levels are within the requirements of
the standards.

CONDUCTION AND MAINTENANCE


The following maintenance operations should be performed every week:
- check that the indicators function;
- check the batteries;
- check that the conductors are tight, check the condition of the terminals.
UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL UNIT IS NOT SUITABLE FOR
USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER
LIVING BEINGS ALIVE

YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL


UNIT BY TELEPHONING ONE OF OUR TECHNICIANS

GB CIM-256/10 11
DIMENSIONS TECHNICAL DATA
288
- BATTERY VOLTAGE SUPPLY 12 Vdc 24 Vdc
- VOLTAGE SUPPLY 8÷ 32V
272 - CIRCUIT LOADING WITH KEY
AT ZERO 13 mA at 12 V
9 mA at 24 V
- MAX LOAD OF THE OUTPUT:
184

-(STOPPING) YELLOW 3A

200
-(STARTING MOTOR) BLACK 40 A
-(GENERALALARM) RED/GREEN 3A
-(AUXILIARY) BROWN 3A
210mm
2,5 m - TEMPERATURE RANGE -10 ÷ +60 °C
D B A C - GSM COMPATIBLE - GSM and DCS (GSM ETS1am)
- HOUR-METER 4 DIGITS
9
83

- OIL PRESSURE GAUGE 0 ÷ 7 bar


- PUMP WATER PRESSURE GAUGE 0 ÷ 21 bar
105

288 - PUMP WATER PRESSURE TRANSMITTER:


• ALLOWED MAX. PRESSURE 21 bar
- ENGINE OIL/WATER
ANTENNA
THERMOMETER +20 ÷ +145°C
- TACHOMETER 4000 rpm
- TIMER 1' ÷ 96 h
- INSTALLATION CONDITIONS FOR EXTERNAL USE
186

PANEL
HOLE - DEGREE OF PROTECTION:
BOX/CONNECTOR IP54/IP20
- CONTROL UNIT WEIGHT 1,6 Kg
- TOTAL WEIGHT 3,3 Kg
273
(CONTROL PANEL + ACCESSORIES + PACKAGE)

ACCESSORIES KIT
ORDERING DATA
- PRE - WIRED FEMALE
CONNECTOR CEM-250-256/10 CODE 70804420
TYPE CIM-256/10 CODE 00211130 - EMERGENCY BRIDGE CONNECTOR CODE 70804421
- PUMP WATER PRESSURE
TRANSMITTER TYPE TPA-200
NIPPLE F1/4" GAS -M3/8”GAS CODE 40500251
- MAGNETIC ANTENNA WITH CABLE CODE 70070163
- NUTS KIT CODE 40179906

CONFORMITY DECLARATION

The company Elcos s.r.l. assumes full responsibility for declaring that the control unit:
Type CIM-256/10
installed and used in the ways and for the purposes described in the user instruction manual complies with
the essential requirements and other relevant provisions laid down by the following directives:
- 1999/05/CE "Directive 1999/5/EC of the European parliament and of the council of
9 March 1999 regarding radio and telecommunications terminal equipment
and the mutual recognition of their conformity",
- 2004/108/CErelated to the electromagnetic compatibility and that repeals the
directive 89/336/CEE,
- 2011/65/UE on the restriction of the use of certain hazardous substances in electrical and
electronic equipment,because it is built and functions in accordance with the harmonized
Standards:
EN61326-1, EN61326/A1, EN61000-4-2, EN61000-4-4, EN61000-4-6, EN60529.
® Parma,06/04/2014
S.r.l.
President
Via Arandora Star, 28/a
I 43122 PARMA ITALIA
Tel. +39 0521/772021 Fax +39 0521/270218
E-mail: [email protected] - HTTP://www.elcos.it Margini Enzo

12 GB CIM-256/10