Rockwool

Fujairah Rockwool slabs are designed for thermal and acoustic insulation, conforming to ASTM C-612 Type IV and BS-3958-5 standards, with a density of 100 kg/m3. They are suitable for high and low temperature applications, are water repellent, and provide excellent thermal conductivity and sound absorption properties. The product is non-combustible, rot-proof, and chemically neutral, making it compatible with various materials in industrial and building applications.

Uploaded by

sreejithms707
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views3 pages

Rockwool

Fujairah Rockwool slabs are designed for thermal and acoustic insulation, conforming to ASTM C-612 Type IV and BS-3958-5 standards, with a density of 100 kg/m3. They are suitable for high and low temperature applications, are water repellent, and provide excellent thermal conductivity and sound absorption properties. The product is non-combustible, rot-proof, and chemically neutral, making it compatible with various materials in industrial and building applications.

Uploaded by

sreejithms707
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

REF: FRF-TDS/1038/2022 DATE: 30 Aug.

2022
Fujairah Rockwool Slabs
With Aluminium Foil Facing on One Side
S2XX
Thickness: As requested
Density: 100 kg/m3

Fujairah Rockwool slabs conforming to ASTM C-612 Type IV and equivalent BS-3958-5 are
designed for thermal and acoustic insulation of flat or slightly curved surfaces. These
slabs are produced from long, non-combustible resin bonded fibers with excellent load bearing
characteristics. They are easy to cut, fit and handle. The robust fibers combine high levels
of thermal efficiency and acoustic absorption.

Service Temperature
Plain Rockwool Insulation has a service temperature of 780°C when tested in accordance with
DIN 52271 for 80mm thickness and 100 kg/m3 density. However, there is possible
deviation for lower densities and with facings.
Applications
Designed for a wide range of applications at both high and low service temperatures. It can be
used on both flat and slightly curved surfaces for thermal and acoustic insulation of ducting,
ovens, vessels and other industrial equipment. Ideal for insulation of flat surfaces of
furnaces, boilers and tanks. It is also suited for fire protection of steel structures,
insulation of bulk heads and ship decks.
Standard Delivery
Available in standard width of 600 mm and length of 1200 mm.
Other sizes are available upon request.
Moisture
Water repellent, non-hygroscopic, non-capillary, and does not absorb any moisture
from the air. Moisture has no effect on the stability of the slabs. Water absorption
test certificate conducted under BS 2972: Section 12 and ASTM C-209 are
available upon request.

Thermal Conductivity
Fujairah Rockwool products show remarkably low thermal conductivity values with typical figures
in accordance with BS 874, equivalent ASTM C 177/C 518. We have test reports
at 35°C mean temperature for 40kg/m3 ,70kg/m3 and 110kg/m3 densities.

Mean k-Value
Temp W/mK
°C 100 kg/m3
24 0.033
35 0.0344
50 0.037
100 0.044
150 0.052
200 0.061
250 0.072
300 0.084
350 0.098
400 0.118

The table shows the test results for their raw density in accordance with the test report.
These results are not binding because they were converted
Acoustic Properties
Typical sound absorption figures are shown below in accordance with BS 3638 & ISO 354 and
equivalent ASTM C 423. We have test certificate for 70kg/m3 and 100kg/m3 densities.
The table shows the test results for their raw density in accordance with the test report.
These results are not binding because they were converted.
Hz 100 kg/m3
125 0.23
250 0.66
500 1.05
1000 1.07
2000 1.05
4000 0.97
NRC 0.95

Note that components of the whole system should be considered for the
Sound Absorption requirement.
Fire Safety
Rockwool Insulation alone is non-combustible when tested in accordance with BS-476: Part 4
1970 and ASTM E-136. Class A, when tested in accordance ASTM E – 84.

Biological Properties
Rot-proof, non-hygroscopic, will not sustain vermin and will not encourage
growth of bacteria, mold or fungi.

Compatibility
Compatible with all other forms of material with which it is likely to come in contact
in normal industrial and building applications.

Chemical Neutrality
Chemically neutral with a pH value of 7-8 when tested in accordance with BS-2972: Section 22. It
will neither cause nor promote corrosion. It meets the requirements of ASTM C-795 the standard
specification for thermal insulation for use in contact with austenitic stainless steel
as per ASTM C-692 (Corrosion test) and ASTM C-871 (Chemical analysis). It contains
low level of chlorides when tested in accordance with BS 2972: Section 21,
ASTM C-871 and AGI Q 135.

Physical Properties
Asbestos-free and shot content is very low when tested as per
ASTM C-1335 and BS-2972 Section 14.

Packing
Supplied in shrink wrapped polyethylene

Unit Price
For details on price our sales office can be contacted.

Technical Advice
For further details of information on technical data, specialist product information, applications,
heat loss calculations or economic thickness, our sales office can be approached.