BAÑOS ADENTRO - Report
BAÑOS ADENTRO - Report
BAÑOS ADENTRO
Preliminary remarks
Notes on planning:
Content
Site 1
Building 1
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site 1 - Building 1
BAÑOS ADENTRO
Room List / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
.............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 .............................
BAÑOS ADENTRO
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
.............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 .............................
Workplane (BAÑOS ADENTRO) / Light scene 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . .21 .............................
(adaptive)
T1
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 .............................
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
.............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 .............................
Workplane (T1) / Light scene 1 / Perpendicular illuminance (adaptive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 ..............................
BAÑOS ADENTRO
Content
T2
Summary / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 .............................
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .............................
32
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34.............................
Calculation objects / Light scene 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35.............................
Workplane (T2) / Light scene 1 / Perpendicular illuminance (adaptive) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37.............................
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
.............................
BAÑOS ADENTRO
Description
5
BAÑOS ADENTRO
Luminaire list
6
BAÑOS ADENTRO
P 21.7 W
ΦLamp 1211 lm
ΦLuminaire 980 lm
η 80.91 %
Polar LDC
Luminous efficacy 45.2 lm/W
CCT 3500 K
CRI 96
ERD6411B_RX407N_RB621F
7
BAÑOS ADENTRO
Building 1
Luminaire list
8
BAÑOS ADENTRO
9
BAÑOS ADENTRO
BAÑOS ADENTRO
T1
T2
10
BAÑOS ADENTRO
11
BAÑOS ADENTRO
12
BAÑOS ADENTRO
Work planes
13
BAÑOS ADENTRO
Ground area: 12.39 m² | Reflection factors: Ceiling: 70.0 %, Walls: 84.4 %, Floor: 75.6 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 3.136 m 14
BAÑOS ADENTRO
Results
g1 0.031 - - WP1
3.23 W/m²/100 lx - -
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
Luminaire list
15
BAÑOS ADENTRO
16
BAÑOS ADENTRO
Fitting 1x
D140_LED_3500K_Mi
ddle
Individual luminaires
X Y Mounting Luminaire
height
17
BAÑOS ADENTRO
18
BAÑOS ADENTRO
19
BAÑOS ADENTRO
Work planes
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
20
BAÑOS ADENTRO
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
21
BAÑOS ADENTRO
Ground area: 1.92 m² | Reflection factors: Ceiling: 70.0 %, Walls: 84.4 %, Floor: 75.6 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 3.136 m 22
BAÑOS ADENTRO
Results
g1 0.22 - - WP3
5.11 W/m²/100 lx - -
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
Luminaire list
23
BAÑOS ADENTRO
24
BAÑOS ADENTRO
Fitting 1x
D140_LED_3500K_Mi
ddle
Individual luminaires
X Y Mounting Luminaire
height
25
BAÑOS ADENTRO
26
BAÑOS ADENTRO
27
BAÑOS ADENTRO
Work planes
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
28
BAÑOS ADENTRO
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
29
BAÑOS ADENTRO
Ground area: 1.90 m² | Reflection factors: Ceiling: 70.0 %, Walls: 84.4 %, Floor: 75.6 % | Light loss factor: 0.80 (fixed) | Clearance
height: 3.000 m | Mounting height: 3.136 m 30
BAÑOS ADENTRO
Results
g1 0.31 - - WP2
3.80 W/m²/100 lx - -
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
Luminaire list
31
BAÑOS ADENTRO
32
BAÑOS ADENTRO
Fitting 1x
D140_LED_3500K_Mi
ddle
Individual luminaires
X Y Mounting Luminaire
height
33
BAÑOS ADENTRO
34
BAÑOS ADENTRO
35
BAÑOS ADENTRO
Work planes
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
36
BAÑOS ADENTRO
Utilisation profile: General areas inside buildings - Rest, sanitation and first aid rooms, Cloakrooms, washrooms, bathrooms, toilets
37
BAÑOS ADENTRO
Glossary
Background area The background area borders the direct ambient area according to DIN EN 12464-1 and
reaches up to the borders of the room. In larger rooms, the background area is at least
3 m wide. It is located horizontally at floor level.
CCT (Engl. correlated color temperature) Body temperature of a thermal radiator that serves
to describe its light color. Unit: Kelvin [K ]. The lesser the numerical value the redder; the
greater the numerical value the bluer the light color. The color temperature of gas-
discharge lamps and semi-conductors are termed "correlated color temperature" in
contrast to the color temperature of thermal radiators. Allocation of the light colors to
the color temperature ranges acc. to EN 12464-1: Light color - color temperature [K]
warm white (ww) 5.300 K
Clearance height The designation for the distance between upper edge of the floor and bottom edge of
the ceiling (in the completely furnished status of room).
CRI (Engl. color rendering index) Designation for the color rendering index of a luminaire or
a lamp acc. to DIN 6169: 1976 or CIE 13.3: 1995. The general color rendering index Ra
(or CRI) is a dimensionless figure that describes the quality of a white light source in
regards to its similarity with the remission spectra of defined 8 test colors (see DIN 6169
or CIE 1974) to a reference light source.
Daylight factor Ratio of the illuminance achieved solely by daylight incidence at a point in the inside to
the horizontal illuminance in the outer area under an unobstructed sky. Formula symbol:
D (Engl. daylight factor) Unit: %
Daylight quotient effective area A calculation surface within which the daylight quotient is calculated.
38
BAÑOS ADENTRO
Glossary
Eta (η) (light output ratio) The light output ratio describes what percentage of the luminous flux
of a free radiating lamp (or LED module) is emitted by the luminaire when installed. Unit:
%
g1 Often also Uo (Engl. overall uniformity) Designates the overall uniformity of the
illuminance on a surface. It is the quotient from Emin to Ē and is required, for instance, in
standards for illumination of workstations.
Illuminance Describes the ratio of the luminous flux that strikes a certain surface to the size of this
surface (lm/m² = lx). The illuminance is not tied to an object surface. It can be determined
anywhere in space (inside or outside). The illuminance is not a product feature because it
is a recipient value. Luxometers are used for measuring. Unit: Lux Abbreviation: lx
Formula symbol: E
Illuminance, adaptive For the determining of the middle adaptive illuminance on a surface, this is rastered
"adaptively". In the area of large illuminance differences within the surface, the raster is
subdivided finer; within lesser differences, a rougher classification is made.
Illuminance, horizontal Illuminance that is calculated or measured on a horizontal (level) surface (this can be for
example a table top or the floor). The horizontal illuminance is usually identified by the
formula letter Eh.
Illuminance, perpendicular Illuminance that is calculated or measured plumb-vertical to a surface. This needs to be
taken into account for tilted surfaces. If the surface is horizontal or vertical, then there is
no difference between the perpendicular and the horizontal or vertical illuminance.
Illuminance, vertical Illuminance that is calculated or measured on a vertical surface (this can be for example
the front of some shelves). The vertical illuminance is usually identified by the formula
letter Ev.
LENI (Engl. lighting energy numeric indicator) Lighting energy numeric indicator acc. to EN
15193 Unit: kWh/m² year
39
BAÑOS ADENTRO
Glossary
LLMF (Engl. lamp lumen maintenance factor)/acc. to CIE 97: 2005 Lamp flux maintenance
factor that takes the luminous flux reduction into account of a luminaire or an LED
module in the course of the operating time. The lamp flux maintenance factor is
specified as a decimal digit and can have a maximum value of 1 (no luminous flux
reduction existing).
LMF (Engl. luminaire maintenance factor)/acc. to CIE 97: 2005 Luminaire maintenance factor
that takes the soiling into account of the luminaire in the course of the operating time.
The luminaire maintenance factor is specified as a decimal digit and can have a
maximum value of 1 (no soiling existing).
LSF (Engl. lamp survival factor)/acc. to CIE 97: 2005 Lamp survival factor that takes the total
failure into account of a luminaire in the course of the operating time. The lamp survival
factor is specified as a decimal digit and can have a maximum value of 1 (no failures
existing within the time concerned or prompt replacement after the failure).
Luminance Dimension for the "brightness impression" that the human eye has of a surface. The
surface itself can emit light thereby or light striking it can be reflected (emitter value). It is
the only photometric value that the human eye can perceive. Unit: Candela per square
meter Abbreviation: cd/m² Formula symbol: L
Luminous efficacy Ratio of the emitted luminous flux Φ [ lm] to the absorbed electrical power P [W] Unit:
lm/W. This ratio can be formed for the lamp or LED module (lamp or module light
output), the lamp or module with control gear (system light output) and the complete
luminaire (luminaire light output).
Luminous flux Dimension for the total light output that is emitted from one light source in all directions.
It is thus an "emitter value" that specifies the entire emitting output. The luminous flux of
a light source can only be determined in a laboratory. A difference is made between the
lamp or LED module luminous flux and the luminaire luminous flux. Unit: Lumen
Abbreviation: lm Formula symbol: Φ
Luminous intensity Describes the intensity of the light in a certain direction (emitter value). The luminous
intensity is a matter of the luminous flux Φ that is emitted in a certain spherical angle Ω.
The radiation characteristics of a light source are presented graphically in a light
distribution curve (LDC). The luminous intensity is an SI base unit. Unit: Candela
Abbreviation: cd Formula symbol: I
40
BAÑOS ADENTRO
Glossary
MF (Engl. maintenance factor)/acc. to CIE 97: 2005 Maintenance factor as decimal number
between 0 and 1 that describes the ratio of the new value of a photometric planning
parameter (e.g . of the illuminance) to a maintenance value after a certain time. The
maintenance factor takes into account the soiling of luminaires and rooms as well as the
luminous flux reduction and the failure of light sources. The maintenance factor is taken
into account either overall or determined in detail acc. to CIE 97: 2005 by the formula
RMF x LMF x LLMF x LSF.
Reflection factor The reflection factor of a surface describes how much of the striking light is reflected
back. The reflection factor is defined by the color of the surface.
RMF (Engl. room maintenance factor)/acc. to CIE 97: 2005 Room maintenance factor that
takes the soiling into account of the space encompassing surfaces in the course of the
operating time. The room maintenance factor is specified as a decimal digit and can
have a maximum value of 1 (no soiling existing).
Surrounding area The ambient area directly borders the area of the visual task and should be planned with
a width of at least 0.5 m according to DIN EN 12464-1. It is at the same height as the
area of the visual task.
UGR (max) (unified glare rating) Measure for the psychological glare effect in interiors. In addition to
luminaire luminance, the UGR value also depends on the position of the observer, the
viewing direction and the ambient luminance. Among other things, EN 12464-1 specifies
maximum permissible UGR values for various indoor workplaces.
UGR observer Calculation point in the room, for the DIALux the UGR value is determined. The location
and height of the calculation point should correspond to the typical observer position
(position and eye level of the user).
41
BAÑOS ADENTRO
Glossary
Visual task area The area that is needed for carrying out the visual task in accordance with DIN EN 12464
-1. The height corresponds with the height at which the visual task is executed.
Wall zone Circumferential area between working plane and walls that is not taken into account for
the calculation.
Workplane Virtual measuring or calculation surface at the height of the visual task that generally
follows the room geometry. The working plane may also feature a wall zone.
42