2331 ZX

Kester 2331-ZX is an organic water-soluble liquid flux designed for soldering circuit board assemblies, offering high ionic cleanliness and neutral pH chemistry. It is compatible with various solder masks and laminates, minimizes cleaning costs, and complies with RoHS regulations. The product has a shelf life of 2 years and requires proper handling and storage due to its flammable nature.

Uploaded by

kimjh4u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views2 pages

2331 ZX

Kester 2331-ZX is an organic water-soluble liquid flux designed for soldering circuit board assemblies, offering high ionic cleanliness and neutral pH chemistry. It is compatible with various solder masks and laminates, minimizes cleaning costs, and complies with RoHS regulations. The product has a shelf life of 2 years and requires proper handling and storage due to its flammable nature.

Uploaded by

kimjh4u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

®

2331-ZX
Organic Water-Soluble Liquid Flux

Product Description Physical Properties


Kester 2331-ZX is an innovation in organic acid Specific Gravity: 0.899 ± 0.005
water-soluble flux chemistry for soldering circuit Antoine Paar DMA 35 @ 25°C
board assemblies. This unique, neutral pH
chemistry flux provides the best ionic cleanliness Percent Solids (typical): 33
Tested to J-STD-004, IPC-TM-650, Method 2.3.34
of any organic water-soluble flux available to the
electronics industry. This popular flux has been
Flash Point: 16°C (60°F)
used for soldering critical assemblies in the
computer, telecommunications and other industries.
No offensive odors will be emitted during soldering. Reliability Properties
Kester 2331-ZX will not create excessive foaming
in standard water cleaning systems. Kester 2331-ZX Copper Mirror Corrosion: High
has good soldering properties for improved Tested to J-STD-004, IPC-TM-650, Method 2.3.32
productivity without sacrificing reliability of the
assembly. This flux does not attack properly cured Corrosion Test: High
Tested to J-STD-004, IPC-TM-650, Method 2.6.15
solder masks or FR-4 epoxy-glass laminate.
Kester 2331-ZX is not detrimental to the surface
Silver Chromate: Fail
insulation resistance of the soldered assembly. Tested to J-STD-004, IPC-TM-650, Method 2.3.33
Use of this flux minimizes cleaning costs while
complying with environmental regulations. Chloride and Bromides: 2.2%
Tested to J-STD-004, IPC-TM-650, Method 2.3.35
Performance Characteristics:
• High activity Fluorides by Spot Test: Pass
Tested to J-STD-004, IPC-TM-650, Method 2.3.35.1
• Minimizes icicling and bridging
• Chemically compatible with most solder masks SIR, IPC (typical): Pass
and board laminates Tested to J-STD-004, IPC-TM-650, Method 2.6.3.3
• pH Neutral Chemistry
• Classified as ORH1 per J-STD-004

RoHS Compliance Blank 2331-ZX


This product meets the requirements of the RoHS Day 1 1.2 ´1010 W 3.4 ´ 108 W
(Restriction of Hazardous Substances) Directive, Day 4 8.7 ´109 W 1.4 ´ 109 W
2002/95/EC Article 4 for the stated banned
Day 7 8.6 ´109 W 1.8 ´ 109 W
substances.
2331-ZX

Application Notes
Flux Application:
Kester 2331-ZX can be applied to circuit boards by a dip, foam or wave process. An air knife after the flux
tank is recommended to remove excess flux from the circuit board and prevent dripping on the preheater
surface.

Process Considerations:
The optimum preheat temperature for most circuit assemblies is 82-88°C (180-190°F) as measured on the
top or component side of the printed circuit board. Dwell time in the wave is typically 2-4 seconds. The wave
soldering speed should be adjusted to accomplish proper preheating and evaporate excess solvent, which
could cause spattering. For best results, speeds of 1.1-1.8 m/min (3½-6 ft/min) are used. The surface tension
has been adjusted to help the flux form a thin film on the board surface allowing rapid solvent evaporation.

Flux Control:
Specific gravity is normally the most reliable method to control the flux concentration. To check concentration,
a hydrometer should be used. Control of the flux in the foam flux tank during use is necessary for assurance
of consistent flux distribution on the circuit boards. The complex nature of the solvent system for the flux
makes it imperative that Kester 4662 Thinner be used to replace evaporative losses. When excessive debris
from circuit boards, such as board fibers and from the air line build up in the flux tank, these particulates will
redeposit on the circuit boards which may create a build up of residues on probe test pins. It is, therefore,
necessary to clean the tank and then replenish it with fresh flux when excessive debris accumulates in the
flux tank.

Cleaning:
No neutralizer, saponifiers or detergents are necessary in the water wash system for complete removal of
flux residues. It is not recommended to use high mineral content tap water. Otherwise, tap, deionized or
softened water may be used for cleaning. The optimum water temperature is 54-66°C (130-150°F), although
lower temperatures may be sufficient.

Storage and Shelf Life:


Kester 2331-ZX is flammable. Store away from sources of ignition. Shelf life is 2 years from date of
manufacture when handled properly and held at 10-25°C (50-77°F).

Health & Safety:


This product, during handling or use, may be hazardous to health or the environment. Read the Material
Safety Data Sheet and warning label before using this product.

World Headquarters: 800 W. Thorndale Avenue, Itasca, Illinois, 60143 USA


Phone: (+1) 630 616-4000 • Email: [email protected] • Website: www.kester.com
Asia Pacific Headquarters European Headquarters Japanese Headquarters
500 Chai Chee Lane Zum Plom 5 20-11 Yokokawa 2-Chome
Singapore 469024 08541 Neuensalz Sumida-Ku
(+65) 6449-1133 Germany Tokyo 130-0003 Japan
[email protected] (+49) 3741 4233-0 (+81) 3-3624-5351
[email protected] [email protected]

The data recommendations presented are based on tests, which we consider reliable. Because Kester has no control over the conditions of use, we disclaim any responsibility connected with the
use of any of our products or the information presented. We advise that all chemical products be used only by or under the direction of technically qualified personnel who are aware of the poten-
tial hazards involved and the necessity for reasonable care in their handling. The technical information contained herein is consistent with the properties of this material but should not be used in
the preparation of specifications as it is intended for reference only. For assistance in preparing specifications, please contact your local Kester office for details.
Rev: 10Feb10

You might also like