0% found this document useful (0 votes)
20 views17 pages

CMM366A-WIFI en

The CMM366A-WIFI Cloud Monitoring Communication Module enables real-time monitoring of generator sets via a WIFI connection to a cloud server, utilizing various communication ports such as RS485, RS232, LINK, and USB. It features multiple programmable parameters, alarm inputs/outputs, and a user-friendly interface for configuration through a PC. The module is designed for easy installation and includes troubleshooting guidelines for common issues.

Uploaded by

marco marquez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views17 pages

CMM366A-WIFI en

The CMM366A-WIFI Cloud Monitoring Communication Module enables real-time monitoring of generator sets via a WIFI connection to a cloud server, utilizing various communication ports such as RS485, RS232, LINK, and USB. It features multiple programmable parameters, alarm inputs/outputs, and a user-friendly interface for configuration through a PC. The module is designed for easy installation and includes troubleshooting guidelines for common issues.

Uploaded by

marco marquez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

CMM366A-WIFI

CLOUD MONITORING COMMUNICATION MODULE

USER MANUAL
Chinese trademark

English trademark
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: +86-371-67988888/67981888/67992951
+86-371-67981000 (overseas)
Fax: +86-371-67992952
Web: www.smartgen.com.cn/
www.smartgen.cn/
Email: [email protected]

All rights reserved. No part of this publication may be reproduced in any material form (including
photocopying or storing in any medium by electronic means or other) without the written permission of
the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication
should be addressed to SmartGen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective
companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.

Table 1 – Software Version

Date Version Note


2017-12-20 1.0 Original release.
2022-08-22 1.1 Update company logo and manual format.
CONTENT

1 OVERVIEW ................................................................................................................................................. 4
2 PERFORMANCE AND CHARACTERISTICS.............................................................................................. 4
3 SPECIFICATION ........................................................................................................................................ 5
4 PANEL AND TERMINAL DESCRIPTION ................................................................................................... 6
4.1 PANEL INDICATOR AND BUTTONS.................................................................................................. 6
4.2 WIFI ANTENNA INTERFACE ............................................................................................................. 7
4.3 RS485 INTERFACE ............................................................................................................................ 7
4.4 RS232 INTERFACE ............................................................................................................................ 8
4.5 LINK INTERFACE ............................................................................................................................... 8
4.6 USB HOST INTERFACE...................................................................................................................... 8
4.7 USB DEVICE INTERFACE................................................................................................................... 9
4.8 TERMINAL ......................................................................................................................................... 9
5 PROGRAMMABLE PARAMETERS .......................................................................................................... 10
5.1 CONTENTS AND SCOPES OF PARAMETERS ................................................................................ 10
5.2 PC CONFIGURATION INTERFACE .................................................................................................. 12
6 SYSTEM DIAGRAM ................................................................................................................................. 14
7 CASE DIMENSION AND INSTALLATION ............................................................................................... 15
8 TROUBLESHOOTING .............................................................................................................................. 16
9 PACKING LIST ......................................................................................................................................... 17

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 3 of 17


1 OVERVIEW

CMM366A-WIFI Cloud Monitoring Communication Module is WIFI wireless network


communication protocol switch module which can achieve genset (with SCI) connect to Internet. After
logging into cloud server, module will receive corresponding genset controller communication protocol
from cloud server. And module gains genset data via RS485 port, USB port, LINK port or RS232 port
then send the data to corresponding cloud server through WIFI wireless network for achieving user’s
real-time monitoring to running status and searching of running records via APP (IOS or Android) and
PC terminal devices.
CMM366A-WIFI module not only can achieve genset monitoring but also can insert some digital
alarm input/output signal to achieve monitoring of generator room entrance guard, guard against theft
and fire facilities.

2 PERFORMANCE AND CHARACTERISTICS

─ Connect to cloud server via WIFI wireless network, one to one monitoring;
─ Multiple ports for communication with genset control module: RS485, RS232, LINK and USB
(Host); can monitor great majority genset control modules of international first-class brands;
─ Widely power supply: DC (8~35)V, can direct use genset built-in battery;
─ With ARM-based 32-bit SCM, high integration of hardware and strong programming ability;
─ Include with GPS locate function to achieve location information and locate genset;
─ Take JSON network data communication protocol, upload real-time data variation and take
compression algorithm to vastly reduce network flow at the same time;
─ Users can upload monitoring data to the server for analyzing based on the user-defined “history
data upload interval”;
─ When alarm occurs it can upload data to server immediately;
─ 2 auxiliary digital input ports which can receive external alarm signal;
─ 1 auxiliary relay output ports which can output various alarm signals;
─ Perpetual calendar and clock functions;
─ Power and multiple communication status indicators on front panel that working status is clear
at a glance;
─ Lamp test function;
─ Parameter adjust function: users can adjust parameters via USB port;
─ Take standard π-type 35mm guide-rail installation or screw-fixed installation that the module can
be installed in the genset control box;
─ Modular design, self extinguishing ABS plastic shell, light weight, compact structure with easy
installation.

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 4 of 17


3 SPECIFICATION

Table 2 – Technical Data

Items Contents
Operating Voltage DC 8.0V~35.0V, continuous power supply
Standby: ≤2W
Overall Power Consumption
Working: ≤5W
Auxiliary Input Volts free digital Input
Auxiliary Output 1A DC30V Volts free output
USB Host A-type USB female port
RS485 Isolated type
RS232 General type
LINK SmartGen exclusive port
USB Device B-type USB female port
IPX Antenna
WIFI
Support 802.11b/g/n standard
Case Dimensions 72.5mmx105mmx34mm
Working Temperature (-25~+70)°C
Working Humidity (20~93)%RH
Storage Temperature (-25~+70)°C
Weight 0.15kg

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 5 of 17


4 PANEL AND TERMINAL DESCRIPTION

4.1 PANEL INDICATOR AND BUTTONS

Fig.1 – Panel Indicators

Table 3 – Indicators Description

Icon Note
Green LED Light: Power supply normal; connect with cloud server success;
POWER/ALARM
Red LED Light: Common alarm indicator.
Normally Extinguish: RS485 disabled;
RS485(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: USB(Host) disabled;
USB(Red) Normally Light: Communication fail;
Blink: Communication normal.
Extinguish: CMM366A-WIFI login with server unsuccessfully;
WIFI(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: Disabled;
LINK(Red) Normally Light: Communication fail;
Blink: Communication normal.
Normally Extinguish: RS232 disabled;
RS232(Red) Normally Light: Communication fail;
Blink: Communication normal.

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 6 of 17


Internal lamp test/reset key:
Press it for 1s, all the LEDs are illuminated; press it for 10s, reset the module to default and all the
LEDs blink for 3 times.

NOTE: After reset the module, parameters need to be re-configured via PC software. Please operate cautiously.

4.2 WIFI ANTENNA INTERFACE

Connect WIFI antenna with module antenna, which is showing as below,

Fig.2 – WIFI Antenna Connection Diagram

4.3 RS485 INTERFACE

Connect RS485 port with genset control module RS485 port to achieve genset data information.
If communication fails, recommend adding a 120Ω terminal resistor. One end of shielding wire
connects with SCR, the other end hangs in the air.

Fig.3 – RS485 Connection Diagram

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 7 of 17


4.4 RS232 INTERFACE

Connect RS232 port with genset control module RS232 port to achieve genset data information.

Fig.4 – RS232 Connection Diagram

4.5 LINK INTERFACE

Connect LINK port with genset control module LINK port to achieve genset data information.

Fig.5 – LINK Connection Diagram

4.6 USB HOST INTERFACE

Connect A-type USB port with genset control module USB port to achieve genset data information.

Fig.6 – USB HOST Connection Diagram

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 8 of 17


4.7 USB DEVICE INTERFACE

All the parameters can be configured and view CMM366A-WIFI ID&Login password by connecting
USB port with USB disk of PC software.

Fig.7 – USB Connect PC Device

4.8 TERMINAL

Table 4 – Terminals Description

No. Function Cable Size Note


1 B- 1.0mm2 Connected with negative of starter battery.
Connected with positive of starter battery. 3A
2 B+ 1.0mm2
fuse is recommended.
3 Aux. Input 1 1.0mm2 Active when connect to B-.
4 Aux. Input 2 1.0mm2 Active when connect to B-.
Normally
5 1.0mm2
Open
6 Aux. Output Common 1.0mm2 Normally open output 1A DC30V
Normally
7 1.0mm2
Close
8 RS485 B(-) 0.5mm2
Impedance-120Ω shielding wire is recommended,
9 RS485 A(+) 0.5mm2
its single-end earthed.
10 SCR 0.5mm2
11 RS232 RX 0.5mm2
12 RS232 TX 0.5mm2 RS232
13 RS232 GND 0.5mm2

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 9 of 17


5 PROGRAMMABLE PARAMETERS

5.1 CONTENTS AND SCOPES OF PARAMETERS

Table 5 – Parameter Content & Scope

No. Items Parameters Defaults Description


WIFI
0: Disabled; 1: Enabled, auto
1 DHCP Enable (0-1) 1
obtain IP address.
2 IP Address (0-255) 192.168.0.101
All changes of Ethernet (like
3 Subnet Mask (0-255) 255.255.255.0
IP address, Subnet address)
4 Default Gateway (0-255) 192.168.0.2
are active after module
5 DNS Address (0-255) 211.138.24.66
rebooting.
6 MAC Address (0-255) E.g. 00.08.DC.01.02.03
7 SSID (0-65535) 32 characters
8 Password (0-65535) 64 characters
Gateway
20 Chinese characters, letters
1 Site Name (0-65535)
or numbers
2 Server URL (0-65535) www.monitoryun.com 40 characters
3 Server Port (0-65535) 91
4 Security Code (0-65535) 123456 16 characters
GPS
0: Disabled
1 Location Info (0-1) 0
1: Manually Input
2 Longitude ((-180)-180)° 0.000000
GPS location, altitude
3 Latitude ((-90)-90)° 0.000000
information
4 Altitude ((-9999.9)-9999.9)m 100.0
Input Port
Input 1
1 Setting (0-9) 0 Default: Not used
0: Close to Activate
1: Open to Activate
2 Type (0-1) 0
See: Table 6 – Digital Input
Ports Content
3 Delay (0-20.0) 0.0 Action delay
Input 2
1 Setting (0-9) 1 Default: Lamp test
0: Close to Activate
1: Open to Activate
2 Type (0-1) 0
See: Table 6 – Digital Input
Ports Content
3 Delay (0-20.0) 0.0 Action delay
Output
1 Setting (0-14) 0 Default: Not used

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 10 of 17


No. Items Parameters Defaults Description
See: Table 7 – Relay Output
Ports Content

NOTE: Configuration of monitoring genset controller model, communication port, communication baud rate, and
communication ID need to be set on the platform, and monitoring module needs to reboot after setting.

Table 6 – Digital Input Ports Content

No. Item Description


0 Not Used Not used.
1 Lamp Test All the indicators are illuminated when input is active.
2 Remote Control Inhibited Cloud start/stop control is prohibited when input is active.
3 Access Alarm Input Access alarm is uploaded to server when input is active.
4 Fire Alarm Input Fire alarm is uploaded to server when input is active.
5 Alarm Input External alarm is uploaded to server when input is active.
6 Reserved
7 Reserved
8 Reserved
9 Factory Test Mode It is only used for factory hardware port test when active.

Table 7 – Relay Output Ports Content

No. Item Description


0 Not Used Output port won’t output when this item is selected.
1 Digital Input 1 Active Output when auxiliary input 1 is active.
2 Digital Input 2 Active Output when auxiliary input 2 is active.
3 RS485 Communication Failure Output when RS485 communication fails.
4 Network Communication Failure Output when Network communication fails.
5 LINK Communication Failure Output when LINK communication fails.
6 RS232 Communication Failure Output when RS232 communication fails.
7 Common Alarm Output when there is an alarm.
Send remote control commands via cloud platform with
8 Remote Control Output
fixed output delay 20s.
9 Reserved
10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 Reserved

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 11 of 17


5.2 PC CONFIGURATION INTERFACE

Connecting the USB port of CMM366A-WIFI communication module with PC USB port to configure
the parameters.

Fig.8 – WIFI Configuration

Fig.9 – Gateway Configuration

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 12 of 17


Fig.10 – Module Monitoring Screen

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 13 of 17


6 SYSTEM DIAGRAM

One CMM366A-WIFI module connects with one genset monitor module. It can be connected via
RS485 port, LINK port, RS232 port or USB port.

Figure 11 – CMM366A-WIFI System Application Diagram

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 14 of 17


7 CASE DIMENSION AND INSTALLATION

2 ways for installation: 35mm guide rail in box or screw (M4) installation as below:

Fig. 12 – CMM366A-WIFI Case Dimension

Fig. 13 – CMM366A-WIFI Guide Rail Installation

Fig. 14 – CMM366A-WIFI Screw Installation

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 15 of 17


8 TROUBLESHOOTING

Table 8 – Troubleshooting

Symptoms Possible Solutions


Check power voltage;
Controller no response with power
Check controller connection wirings.
Check Ethernet parameters are correct or not;
Network indicator not light Check Network socket indicator is light or not;
Check cable is normal or not.
Check connections;
Check RS485 port is enabled or not;
RS485 communication abnormal
Check settings of genset ID and baud rate are correct or not.
Check RS485’s connections of A and B is reverse connect or not.
Check connections;
RS232 communication abnormal Check RS232 port is enabled or not;
Check settings of genset ID and baud rate are correct or not.
Check connections;
LINK communication abnormal Check LINK port is enabled or not;
Check settings of genset ID and baud rate are correct or not.

CMM366A-WIFI Cloud Monitoring Communication Module User Manual Page 16 of 17


9 PACKING LIST

Table 9 – Packing List

No. Name Quantity Remark


1 CMM366A-WIFI 1
2 Osculum type WIFI antenna 1
3 120Ω matched resistor 2
4 User manual 1

_________________________________