FAT12
FAT12
ENTRANCE
M THIS SITE
30 mm² THHW wire,
100 A SYMBOLS DESCRITION
ELECTRICAL GENERAL NOTES:
CEILING LIGHT
1. ALL ELECTRICAL INSTALLATIONS HEREIN AND OTHER RELATED WORKS TO BE DONE IN THIS
CHANDELIER
1 15 AMP 15 AMP 2 BUILDING SHALL BE IN ACCORDANCE WITH THE PROVISIONS AND STANDARDS OF THE FOLLOWING:
CONVENIENCE OUTLET 1.1 THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE.
co
1.2 REPUBLIC ACT 7926 OTHERWISE KNOWN AS THE NEW ELECTRICAL ENGINEERING LAW
3 30 AMP 30 AMP 4 RANGE OUTLET 1.3 THE NATIONAL BUILDING CODE OF THE PHILIPPINES.
1.4 FIRE CODE OF THE PHILIPPINES.
r
REFRIGERATOR OUTLET 1.5 EXISTING RULES AND REGULATION OF THE LOCAL POWER UTILITY COMPANY.
5 20 AMP 30 AMP 6
1.6 THE EXISTING CITY/MUNICIPAL ORDINANCES AND,
ref
OUTLET FOR A.C.U 1.7 THE BUREAU OF LABOR STANDARDS.
7 30 AMP SPARE 8 2. ALL ELECTRICAL INSTALLATIONS HEREIN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A
CCTV DULY REGISTERED ELECTRICAL ENGINEER. HE SHALL BE RESPONSIBLE IN THE INTERPRETATION
OF THE PLANS AND SPECIFICATION AND THE REQUIRED STANDARDS OF THE ELECTRICAL CODE.
EMERGENCY LIGHT 3. MATERIALS AND EQUIPMENT TO BE USED SHALL HAVE INSPECTED COMMODITY CLEARANCE (ICC)
LABEL FOR FOREIGN MADE PRODUCTS AND P.S. MARK FOR LOCAL IN NATURE OF THE BUREAU OF
TELEPHONE
PRODUCT STANDARD (BPS).
#8 Copper grounding 4. PROVIDE GROUNDING WIRE TO ALL OUTLETS AND LIGHTING CIRCUITS, ALL NON CURRENT
ETHERNET PORT
CARRYING METAL PARTS SHALL BE GROUNDED AND BOBDED INCLUDING FENCE AND GATE.
SD 5. ALL PANEL BOARDS, MAIN DISTRIBUTION PANELS, ETC., SHALL HAVE GROUNDING BUS FOR
SMOKE DETECTOR
ONE LINE DIAGRAM M WATT HOUR-METER
6.
BRANCH CIRCUITS AND SUB FEEDER GROUNDING SYSTEM SHALL BE BONDED TO THE NEAREST
METAL WATER PIPE.
MOUNTING HEIGHT FOR ALL WIRING DEVICES AND PANEL BOARDS SHALL BE.
PANEL BOARD - PB 6.1 LIGHTING OUTLETS 1.40M ABOVE FLOOR FINISH.
PB
6.2 CONVENIENCE OUTLETS 0.30M ABOVE FLOOR FINISH.
CIRCUIT HOMERUN
6.3 TELEPHONE OUTLETS 0.30M ABOVE FLOOR FINISH.
6.4 PANEL BOARDS & CABINETS 1.40M ABOVE FLOOR FINISH.
POWER SOURCE 7. WIRING METHODS SHALL BE AS FOLLOWS:
7.1 SERVICE ENTRANCE RESISTS INTERMEDIATE METALLIC
GROUND LUGS CONDUIT (IMC).
7.2 LIGHTING AND POWER SYSTEM POLYVINYL CHLORIDE (PVC).
AY 7.3 TELEPHONE OUTLETS POLYVINYL CHLORIDE (PVC).
HW LIGHTING CIRCUIT LINE
HIG 7.4 ALL VIBRATING EQUIPMENTS LIQUID TIGHT FLEXIBLE METAL
AL
ION
POWER CIRCUIT LINE
CONDUIT.
NAT 8. NO CHANGES OR MODIFICATION SHALL BE MADE WITHOUT THE DESIGNERS WRITTEN CONSENT.
S1 1 Gang Switch
9. ALL WORKS SHALL BE EXECUTED IN A WORKMANSHIP MANNER AND SHALL PREVENT A NEAT AND
BA
S2 2 Gang Switch ORDERLY ACCEPTANCE. ALL WIRING SHALL BE CONCEALED IN THE LEAST POSSIBLE WAY.
R
AN
3 Gang Switch
G
S3
AY
ST
R
EE
T
TH
IS
ELECTRICAL SYMBOLS
SI
TE
VICINITY MAP
SUBMITTED BY: PROPOSED SINGLE SUBJECT: INSTRUCTOR: 7
STEPHE FATIMA G. MAGALLON STOREY HOUSE PLAN ES 311 - CIRCUIT 1 ENGR. RIZA L. MULLE
WITH TWO BEDROOMS (TTH- 5:30PM - 7:00PM) 7