0% found this document useful (0 votes)
65 views3 pages

ZDW3 Brochure

The ZYOPTIX Diagnostic Workstation (ZDW3) is designed to assist surgeons with extensive diagnostic data and features an easy-to-navigate graphical user interface. It includes advanced networking capabilities for seamless communication with the TECHNOLAS TENEO 317 excimer laser and incorporates improved measurement tools such as the ZYWAVE3 Wavefront Analyzer and ORBSCAN3 Anterior Segment Analyzer. The workstation is equipped with a high-performance all-in-one PC and offers a range of specifications for accurate eye analysis and treatment preparation.

Uploaded by

alokmishraji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views3 pages

ZDW3 Brochure

The ZYOPTIX Diagnostic Workstation (ZDW3) is designed to assist surgeons with extensive diagnostic data and features an easy-to-navigate graphical user interface. It includes advanced networking capabilities for seamless communication with the TECHNOLAS TENEO 317 excimer laser and incorporates improved measurement tools such as the ZYWAVE3 Wavefront Analyzer and ORBSCAN3 Anterior Segment Analyzer. The workstation is equipped with a high-performance all-in-one PC and offers a range of specifications for accurate eye analysis and treatment preparation.

Uploaded by

alokmishraji
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ZDW 3

ZYOPTIX DIAGNOSTIC WORKSTATION3


®

TECHNICAL SPECIFICATIONS

M a r ked
CE

See better. Live better.

ZDW3 TS Brochure 1208_2015 Print.indd 1 26/08/15 12:20


ZYOPTIX® DIAGNOSTIC WORKSTATION3 –

TECHNICAL SPECIFICATIONS

ZDW3 Diagnostic Workstation


The ZYOPTIX Diagnostic Workstation (ZDW3) has been developed to:

• Guide the surgeon in their choice of surgery by an extensive number


of presented diagnostic data, maps and indices.
• Allow a sophisticated, icon driven, and therefore easy to navigate and operate
graphical user interface GUI with integrated automatic eye (OD/OS) recognition.
• Offer optimal preparation for a treatment through the advanced network
communication available with the TECHNOLAS refractive product platform.
ZDW 3 Full Data Access and Connectivity
The ZDW3 introduces significant improvements including :
Within a centralized computer network the TECHNOLAS® TENEO™ 317 works seamlessly
• Updated product design with the Diagnostic Workstation3 complementing both data transfer and ergonomics.
• Icon driven GUI
• Simplified workflow:
• ORBSCAN® and ZYWAVE® > combined software
• Ease of Use: Patient Selection > Measurement > Evaluation
• Treatment Calculator integrated
ZYWAVE3 Wavefront Analyzer
• 21.5” high performance all-in-one PC (computer integrated into TouchScreen) • Measures, analyzes and displays the presence of higher and lower order aberrations.
• Diagnostic networking • Provides all necessary data for iris recognition as well as compensation
• Directly linked to centralized database for pupil center shift and cyclotorsion at the TECHNOLAS® TENEO™ 317.
• Easy communication and fast exchange of data with
the TECHNOLAS ® TENEO™ 317 excimer laser This version of the ZYWAVE³ has a nine (9) times higher
resolution (lenslets / centroids) than the previous model plus an
HD Camera with high-speed data transfer technology.
ORBSCAN3 Anterior Segment Analyzer
The ZYWAVE3 has an integrated pupillometer and displays the
The ORBSCAN3 Anterior Segment Analyzer is the further evolution of the proven multidimensional following measurements:
ORBSCAN® Topographer. It provides a complete contact-free analysis of the eye’s anterior segment
by utilizing slit scanning technology with an advanced Placido disc system. The ORBSCAN3 has a higher • Summary screen with all important data
resolution, providing up to 23,000 points of recognition instead of the 9,000 with the previous model. for treatment evaluation
ORBSCAN3 functional specifications: • 2D Plot
• Predicted Phoropter Refraction (PPR)
• Anterior corneal elevation and curvature versus Pupil Diameter
• Posterior corneal elevation and curvature • Higher Order Point Spread Function (PSF)
• Keratometry maps • Raw Data
• Full corneal pachymetry • Normal Band
• Anterior chamber depth • Difference Map
• Pre- and post-op difference map
• White-to-white diameter Significant improvements have been made such as the parallel
• Angle kappa display of pupil and centroid images which allows for:
• Sim K
• Irregularity index • Online assistance for patient‘s eye centration
• Improved measurement guidance for patient’s
eye with cataract or IOL

ZDW3 TS Brochure 1208_2015 Print.indd 2-3 26/08/15 12:20


ZDW3 Technical Specifications
Software Specifications
Operating System Microsoft® Windows 7
Hardware Specifications
All-In-One Computer Intel Core i7
(2.2 GHz)
RAM memory 4 GB DDR3 RAM, 1333 MHz ZYWAVE3 Technical Specifications
Graphics card Integrated Intel® HD Graphics
with 1920x1080p Measurement data
Touch Screen 21.5” wide TFT color LCD (16:9) Measurement range Sph + 6.00 to -12.00 dpt
Cyl. 0.00 to 5.00 dpt
Axis 0° to 180°
XYZ - Positioner Diameter of pupil 2.5 to 8.5 mm
Designed for comfortable and accurate device adjustment
X-axis: ± 35mm Measurement system
Y-axis: ± 37mm Light source Laser diode
Z-axis: ± 16mm Laser protection class 1
Wavelength 785 ± 5mm
Chin Rest Operating type Continuous wave (cw)
Designed for comfortable and accurate positioning of the Power on the cornea ≤ 50 µW
patient’s head during the measurement process Period of exposure 1 - 2s (without pre-scan)
Z-axis chin rest: ≥ 50mm Beam release Via trigger button

General Specifications NoDiZy No dilation required for myopic eyes


Protection from liquid ingress IP2X
Power Voltage 100 - 240V Hardware Specifications
Rated power input max. 260 VA Camera Two (2) digital CCD cameras

ORBSCAN3 Technical Specifications


Functional Specifications
Field of view 12 x 16 mm
Anterior cornea Elevation
Posterior cornea Elevation
Pachymetry card Optical, non contact
Elevation data points Up to 23,000 points
Keratometric card Placido
Placido disc resolution Up to 4,000 points / 18 rings
Angular resolution 1° steps / 360°
Iris / Lens resolution 5,000 points (typically)

Hardware Specifications
Camera Digital CCD camera
Light Source LED (white)

ZYOPTIX® Diagnostic Workstation has CE Mark. TECHNOLAS® TENEO™ 317 Excimer Laser has CE Mark.
Indications may vary by country. Please contact our regional representative regarding individual availability in your respective market.
The trademarks (™ and ®) and logos used in this document are the property of Bausch & Lomb Incorporated or its affiliates.
kbcomunicacion Ref BLT 012-08/15.
© 2015 TECHNOLAS Perfect Vision GmbH. All rights reserved.

TECHNOLAS Perfect Vision GmbH – A Bausch + Lomb Company


Messerschmittstr. 1+3, Munich, Germany
www.technolas.com – www.bausch.com

See better. Live better.