JC400 command list for custom (1)
JC400 command list for custom (1)
2
Command
Module Command Function Format
Category
Add an APN APN,<A>,<B>
APN settings
APN,<A>,<B>,<C>,<D>,<E>,<F>
Add an APN (in detail) ,<G>,<H>,<I>,<J>,<K>,<L>,<M>,
<N>
GPS clock
GPS time TIMESYNC,A#
synchronization
Device
Management
Parameter settings
Set the independent switch for a
RECORDSW,<A>,<B>
camera
Video
Set the rotation angle of the camera image.
RATATION,<A>,<B>
Recording Image setting
Location packet
Set the interval for uploading
TIMER,<A>,<B>
location packets
Tracking
Fuel level sensor Set the ID of the fuel level sensor. OILIDSET,<A>,<B>
DMS
Whether to start face alignment DMSCALIBRAT,<A>
DMS_CALIB_ABNORMAL,<A>,
Alignment exception event
<B>,<C>
RLOGIN,<Account
Set login information
number>,<Password>
System
mmand List V4.2
Comment
A=Name of the AP
B=Address of the AP
A=0/1/2
It is a function switch, wherein 0 means the function is off, 1 transparent transmission over
TCP, and 2 transparent transmission over HTTP.
B=1/2
It refers to the transmission mode, wherein 1 means timed upload and 2 means re-upload.
C=1–10 (TCP)/10–100 (HTTP)
It refers to the sampling rate and the unit is samples per second. The default value 6 samples
per second for transmission over TCP and 100 samples per second for transmission over
HTTP.
D=1–60
It refers to the time for timed upload and the unit is second. The time for timed upload over
TCP is 2s (unchangeable) and the time for timed upload over HTTP is 10s.
To initialize the G-sensor of the device, park your vehicle in a flat road and deliver this
command to the device.
A=2/4/8/16
It specifies the measuring range
A=Old password, which is required or the set will fail
B=New password, which should be 6 digits
A=IN/OUT
It refers to the camera channel that streams the video, wherein IN refers to the main camera
and OUT the subcamera.
B=0/90/180/270 degrees
It refers to the angle of rotation, wherein: 0: No rotation
90: 90° rotation
180: 180° rotation
270: 270° rotation
A=0/1; It defines the resolution of the videos captured by the front camera.
0=1920x1080, bitrate 8M
1=1280x720, bitrate 4M
A=0/1
It refers to the unit of the speed, wherein "0" refers to "km/h" and "1" "mph".
A=0/1/2/3, wherein "0" means off, "1" "JIMI", "2" "TruckXInc", and "3" "Creare Sistems".
It indicates whether to display the company name at the lower right corner of the video.
A=ON/OFF
It is a switch used to specify whether the device will auto upload a location packet to notify the
user every time the ACC status changes.
A=ON/OFF
B=angle,5~45, default is 10
A=ON/OFF
It is a function switch. When A is set to "ON", the device will re-upload a location packet every
time an event is triggered.
Query the location and alert packets that are cached in the device and have not been
uploaded
A=Event type (input the codes of different types of events, see the attachment for details)
B=1–60; It defines the time interval to trigger a same-type event after the last one (input a
value)
The unit is minute (min) and the default value is 5
A=Event type (input the event code of an event type)
B=ON/OFF
It indicates whether to upload event videos automatically or on demand.
A=Event type (input the event code of an event type)
B=ON/OFF; Enable/Disable the alert tone
A=10/15/30/60, default is 7
It indicates the length of a video captured before an event is triggered when the device is ACC
ON. The unit is second.
B=10/15/20/30/60, default is 15
It indicates the total length of a video captured before and after an event is triggered. The unit
is second.
A=ON/OFF
Function switch, wherein the device will alert once an SOS event is triggered
B=Report mode of alerts
0: GPRS, 1: SMS+GPRS, 2: GPRS+SMS+Call, 3: GPRS+Call
A=SOS number 1 to add
B=SOS number 2 to add
C=SOS number 3 to add
Delete one or multiple SOS numbers by their number sequences.
A=ON/OFF; Default: ON
B=1/2/3; It refers to the trigger sensitivity; 1: Low, 2: Mid, 3: High; Default: 2
T=1–30; It refers to the delay time; The unit is minute (min) and the default value is 5
A=1–255. It specifies the sensitivity range, wherein the lower the value, the more sensitive the
vehicle to detect a vibration.
This command is the same as the SENALM command, but it is more specific.
A=10–600 (seconds).
It refers to the time during which a vibrating alert won't be triggered if the device is ACC ON
during that time.
A=ON/OFF. It specifies whether to enable the feature to trigger an alert when the memory
card is inserted or removed.
B=0–3. It specifies the alert mode. Default: 2.
A=ON/OFF; Default: ON
M=1/2/3; It refers to the trigger sensitivity; 1: Low, 2: Mid, 3: High; Default: 2
A=1–255 (the lower the value, the more sensitive the device to sense a collision)
It is used to query the size of images in the device that are taken via this feature.
A=0/1/2/3.
It refers to the interface for user identification, wherein "0" means the switch is "off", "1"
refers to the "card reader", "2" refers to "RFID", and "3" refers to "facial recognition".
A=0–60 (min). It refers to the interval to collect fuel level data when the vehicle is ACC OFF
and the value "0" indicates the sensor will not collect data.
B=0–60 (min). It refers to the interval to collect fuel level data when the vehicle is ACC ON and
the value "0" indicates the sensor will not collect data.
C=1–10000. It refers to the difference between the fuel level data collected before and after
the vehicle is ACC OFF, at which value a fuel exception alert will be triggered. The accuracy is
"0.01".
D=1–10000. It refers to the difference between the fuel level data collected before and after
the vehicle is ACC ON, at which value a fuel exception alert will be triggered. The accuracy is
"0.01".
For example: If the value is set to "1000", the corresponding value is 10 (1000*0.01), which
means an alert will be triggered if the difference between two measurements is greater than
10%. The default value is "1000".
A=0/1. It refers to the fuel level sensor to set. The device supports two fuel level sensors: A
and B.
0: Fuel level sensor A; 1: Fuel level sensor B
B=0–254.
It refers to the ID of the fuel level sensor to set (The IDs for the two fuel level sensors should
be set differently)
If no parameters are specified in a query command, the device will return the data of the two
fuel level sensors.
A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
Set a period during which the device will not repeatedly give out voice announcements for the
same type of events.
Default=5s [The unit is second (s), wherein you can set the report interval to "0" to always
disable the voice announcement or to 10, 30, or 60].
A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
Set a period during which the device will not repeatedly send alert messages of the same type
of events to the platform.
Default=120s [The unit is second (s), wherein you can set the report interval to "0" so the
device will never upload the alert messages to the platform or to 180, 600, or 1800]
A=0/1
0: End
1: Start
A=0–120
This parameter, once successfully set, becomes invalid after the device re-enters ACC OFF.
A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
It is used to specify the duration during which the device continues to detect a bad behavior of
the driver before an event is triggered.
Default=3s [The unit is second (s) and the value range is 1–10].
A=1–10. It indicates after how many alignment exceptions will the device generate a relevant
alert. If A is set to "0", the feature is disabled.
B=0/1 (1: On, 0: Off ); Whether to notify the user via sound upon an alignment exception.
C=0/1, wherein "0" indicates do not upload and "1" indicates upload. It is used to set whether
to upload alignment exception messages to the platform.
A=HTTP address.
Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.
A=0/1. It refers to the working logic, wherein "0" refers to the integrated version and "1" the
distributed version.
Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.
Get the images taken by the inward camera from the device.
Get the images taken by the front camera from the device.
Get the images taken by the inward and front cameras from the device.
A=ON/OFF. ON means to enable RTMP streaming; while OFF means to stop RTMP
streaming.
B: IN/OUT. IN refers to the inward camera and OUT the front camera. The default value is IN.
It is used to get the main information of the device via wifikit, wherein the information includes
(the name of the project/device IMEI/free space and total space of the SD card/software
version/hardware version/the number of satellites that have been engaged in
positioning/network signal)
APN#unim2m.gzm2mapn#unim2
m.gzm2mapn
ROAMING,ON
WIFIAP,ON,ABCD,12345678
BTNAME,ON
VOLUME,2
VOICESW,1
LED,ON
TIMESYNC,gps
TIMEZONE,+08:00
GTRANS,2,2,100,10
RANGE,2
PASSWORD,123456
LOG,106.53.71.26,60108,/
sdcard/C28Log
PING,HTTP
RECORDAUDIO,0
RECIRDSW,1,1
MIRROR,in,OFF
RATATION,IN,90
VIDEORESOLUTION,0
MILE,0
LOGOSW,0
ACCREP,OFF
TIMER,ON,10
ANGLEREP,ON,15
EVENTGPS,OFF
VIBRATE PHONECALLING
OVERSPEED SHELTER
RAPIDACC RELAYOFF
RAPIDDEC RELAYRECOVERY
FILTER,CRASH,5 RAPIDTURN MISSINGFACE
DRIVE NOSDCARD
DRIVE NOSDCARD
POWER SDCARDMOUNT
UPLOADSW,CRASH,ON VOLTAGELOW OIL
CLOSEEYES OILTO
ALARMTONE,CRASH,ON YAWN TEMPTO
VIDEOPARAM,7,15
EXBATALM,0,115
FATIGUE,ON,4,5
SPEED,ON,10,90,1
SOSALM,ON,1
SOS,A,123456789
SOS,D,123456789
CALL,2
SENALM,ON,2
DEFENSE,ON
DEFENSE_TIME,5
SHOCK,10
SHAKEDELAY,60
NOSDCARDALM,ON,2
CRASHALM,ON,2
SENSOR,255
RAPIDACC,ON,2
RAPIDADEC,ON,2
RAPIDTURN,ON,2
RAPIDTEST,30,40,70
PICTIMER,ON,300,1
RELAY,1
SPEEDOMETER,ON
CARDREADER,ON
EXDEVICESW,1
OILPARAM,1,1,1000,1000
OILIDSET,0,01
TEMPCOLLECTINTERVAL,1,1
DMS_VOICE_CUSTOM,10,10,10
,10,10,10
DMS_ALERT_CUSTOM,180,180,
180,180,180,180
DMSCALIBRAT,1
DMS_VIRTUAL_SPEED,30
DMS_CONTINUITY,3,3,3,3,3,3
DMS_CALIB_ABNORMAL,3,1,0
UPLOAD,http://www.baidu.com/
upload
HTTPUPLOADLIMIT,5,3
FILELIST,http://www.baidu.com
SERVER,1,dvrdev.tracksolidpro.c
om,21100
RSERVICE,192.168.0.1:1935/live
COREKITSW,0
Picture,in
Picture,out
Picture,inout
Video,in,3s
Video,out,3s
Video,inout,3s
RTMP,ON,OUT
RLOGIN,jimi,88888888
HVIDEO,2020_01_01_24_05_06,
1
EVIDEO,2020-06-15 12:12:12,1
UPLOADFILE,EVENT_35773009
0564767_00000000_2021_01_29
_07_28_18_F_05.mp4