0% found this document useful (0 votes)
1K views18 pages

JC400 command list for custom (1)

The document is a command list for the JC400 device, detailing various commands for managing settings such as APN, roaming, WiFi hotspot, Bluetooth, volume, and device LEDs. It also includes commands for device management, video recording, location tracking, event features, and accessories. Each command is formatted with specific parameters to enable or disable functions, set thresholds, and configure device behavior.

Uploaded by

Express Atr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views18 pages

JC400 command list for custom (1)

The document is a command list for the JC400 device, detailing various commands for managing settings such as APN, roaming, WiFi hotspot, Bluetooth, volume, and device LEDs. It also includes commands for device management, video recording, location tracking, event features, and accessories. Each command is formatted with specific parameters to enable or disable functions, set thresholds, and configure device behavior.

Uploaded by

Express Atr
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 18

JC400 Command List V4.

2
Command
Module Command Function Format
Category
Add an APN APN,<A>,<B>

APN settings
APN,<A>,<B>,<C>,<D>,<E>,<F>
Add an APN (in detail) ,<G>,<H>,<I>,<J>,<K>,<L>,<M>,
<N>

Roaming Enable or disable roaming ROAMING,<A>

WiFi hotspot Turn on/off the WiFi hotspot WIFIAP,<A>,<B>,<C>

Bluetooth Turn on/off the Bluetooth BTNAME,<A>

Volume settings Set the volume of the device VOLUME,<A>

Change the language of the voice


Voice prompt language VOICESW,<A>
prompts

Device LEDs Set the device LEDs LED,<A>

GPS clock
GPS time TIMESYNC,A#
synchronization

Clock synchronization Set the time zone TIMEZONE,A#

Device
Management

G-sensor data Collect and upload data GTRANS,<A>,<B>,<C>,<D>

G-sensor data Calibration GCALIBRAT

G-sensor data Range settings RANGE,<A>

Admin password Change the password PASSWORD,<A><B>

Query the firmware version VERSION

Restore to factory settings RESTORE

Restart the device REBOOT


Upload logs LOG,ALL

Basic information and


maintenance of the
device
Basic information and Upload the logs to a specific TCP
maintenance of the LOG,<A>,<B>,<C>#
server.
device
Query the device status STATUS
Query the parameters
PARAM

Test the connectivity PING,<A>,<M>

Format the memory card FORMAT

Whether to record audio along with


RECORDAUDIO,<A>
the video

Parameter settings
Set the independent switch for a
RECORDSW,<A>,<B>
camera

Control the mirroring of the backup


MIRROR,in,<A>
camera (rear-view)

Video
Set the rotation angle of the camera image.
RATATION,<A>,<B>
Recording Image setting

Set the video quality of the front


VIDEORESOLUTION,<A>
camera (main camera)

Set the unit of speed MILE,<A>

Set whether to display the company logo


LOGOSW,<A>

Whether to auto upload a location


packet every time the ACC status ACCREP,<A>
changes

Location packet
Set the interval for uploading
TIMER,<A>,<B>
location packets

Tracking

Set the angle value for uploading


ANGLEREP,<A>,<B>
location

Event-generated location packet re-


EVENTGPS,<A>
upload

Event-generated alert packet re-


BUFFERCACHEQUERY
upload

Set the interval for the device to


Parameter settings FILTER,<A>,<B>
trigger the same type of events
Whether to auto upload event
UPLOADSW,<A>,<B>
videos

Event-triggered Whether to enable alert tone for a


ALARMTONE,<A>,<B>
response specific event type

Set the event video length VIDEOPARAM,<A>,<B>

Vehicle undervoltage Set the threshold voltage to trigger


EXBATALM,<A>,<B>#
alert such an alert

Fatigue driving Set parameters for fatigue driving FATIGUE,<A>,<B>,<C>

Set the parameters related to the


Speeding SPEED, <A>, <T>, <S>,<M>
speed alert

Set whether to alert for SOS events


and how these alerts will be SOSALM,<A>,<B>
uploaded
SOS numbers and
alerts
Event Feature Add SOS numbers SOS, A, <A>, <B>, <C>

Delete SOS number(s) SOS, D <A>, <B>, <C>

Set how many calls will the device


SOS alert initiate to the SOS numbers when CALL,<A>
an SOS alert is triggered

Set the sensitivity to trigger a


vibrating alert when the vehicle SENALM,<A>,<B>
stops.
Parking vibration
Set the defense mode DEFENSE,<A>
Set the delay for the device to enter
DEFENSE_TIME,<T>
defense mode

Set the sensitivity to detect vibration


Vibrating during parking SHOCK,<A>
during parking

Set the delay to trigger a vibrating


Vibrating during parking SHAKEDELAY,<A>
alert

The memory card is inserted or


Memory card error NOSDCARDALM,<A>,<B>
removed
Set the sensitivity to trigger a
Driving collision CRASHALM,<A>,<M>
collision alert
Set the sensitivity to trigger such a
Collision during driving SENSOR,<A>
collision alert

Set the harsh acceleration alert RAPIDACC,<A>

Driving behavior alert


Set the harsh braking alert RAPIDDEC,<A>
settings

Set the harsh cornering alert RAPIDTURN,<A>

Set the threshold to trigger an


RAPIDTEST,<A>,<B>,<C>
aggressive driving behavior alert

Timed image taking Set parameters PICTIMER,<A>,<B>,<C>

Query the size of images in the


Timed image taking TIMERPICRAM
device that are taken via this feature

Delete images that are taken via


Timed image taking TIMERPICRAM,DEL
this feature from the device
Remotely cut off the fuel/power of
Relay RELAY,<A>
the vehicle

Speedometer It is a function switch SPEEDOMETER,<A>

It is a function switch CARDREADER,<A>


Card reader Set the permission level for the card DRIVERLEVEL,<A>,<B>,<C>,<X
reader >

RFID It is used to identify the user EXDEVICESW,<A>

Set the threshold fuel level at


Accessories Fuel level sensor which the sensor will generate an OILPARAM,<A>,<B>,<C>,<D>
alert

Fuel level sensor Set the ID of the fuel level sensor. OILIDSET,<A>,<B>

Set the interval to collect TEMPCOLLECTINTERVAL,<A>,


Temperature sensor
temperature data <B>
Set the format of the data collected
Temperature sensor TCALIBRAT#
by the temperature sensor

Set the device to filter same voice DMS_VOICE_CUSTOM,


announcements <A>,<B>,<C>,<D>,<E>,<F>

Set the device to filter alerts for the DMS_ALERT_CUSTOM,


same type of events <A>,<B>,<C>,<D>,<E>,<F>

DMS
Whether to start face alignment DMSCALIBRAT,<A>

DMS simulation speed DMS_VIRTUAL_SPEED,<A>

Set the duration during which the


DMS_CONTINUITY,
device will keep aligning the driver's
<A>,<B>,<C>,<D>,<E>,<F>
face.

DMS_CALIB_ABNORMAL,<A>,
Alignment exception event
<B>,<C>

Over-HTTP upload Modify the HTTP address UPLOAD,<A>

Query the address of the HTTP


Over-HTTP upload HSERVICE
server

It defines the mechanism


Over-HTTP
to deal with
upload
such a situation as the platform doesn't respond
HTTPUPLOADLIMIT,<A>,<B>
after the device uploads data over HTTP.

History videos server Settings FILELIST,<A>


TCP Server Set the address of the TCP server SERVER,<M>,<A>,<P>

RTMP server Set the address of the RTMP server RSERVICE,<Address>

Work mode of the


Switch platforms COREKITSW,<A>
platform

Take images via the


inward camera of the Picture,in
device
Take images via the
front camera of the Picture,out
device
Take images via the
inward and front
Picture,inout
cameras
simultaneously
Capture videos via the
inward camera of the Video,in,Ns
device
Capture videos via the
front camera of the Video,out,Ns
device
Capture videos via the
inward and front
Video,inout,Ns
cameras
simultaneously

Set RTMP streaming RTMP,<A>,<B>

RLOGIN,<Account
Set login information
number>,<Password>

Remote video upload Upload sub-streams for one minute. HVIDEO,<A>,<B>

Remote video upload Generate and upload event videos EVIDEO,<A>,<B>,<C>

Upload videos of a specific event


Communic Event videos type (a command to upload video UPLOADFILE,<A>
files on demand)
ation

WIFIKIT Get the information of the homepageWIFIKIT, Get_first_page_info

System
mmand List V4.2
Comment
A=Name of the AP
B=Address of the AP

A=Name / B=APN / C=MCC / D=MNC


E=Type / F=Proxy / G=Port / H=User
I=Server / J=Password / K=mmsc / L=mmsproxy / M=mmsport / N=numeric
When only A, B, C, and D are required to be set for the APN, you can deliver it as a simple
parameter; while if more parameters ("E" and these following it) are required to be set,
commas (,) should be used to separate these parameters.
A=ON/OFF
It is the roaming switch.
A=ON/OFF WiFi hot-pot switch.
B=Hot-pot name, default is IMEI number
C=password, default is last 8 digits of IMEI
A=ON/OFF
It is a switch to enable the Bluetooth. Only when A is set to "ON" will the device enable the
Bluetooth after entering ACC ON mode.
A=0/1/2/3; It defines the volume level of the device.
0-Mute, 1-Low, 2-Mid, 3-High
A=0/1/2/3/4/5/6/7/8; It defines the language of the voice prompts given out by the device,
wherein:
0-English, 1-Chinese, 2-Thai, 3-Arabic, 4-British English, 5-Russian, 6-Portuguese, 7-
Spanish, 8-Indonesian
A=ON/OFF
It defines whether to light on LEDs (all-day).
A=gps/network
It indicates the way used by the device to synchronize its system time.
A=Time zone
Input a time zone, such as +08:00

A=0/1/2
It is a function switch, wherein 0 means the function is off, 1 transparent transmission over
TCP, and 2 transparent transmission over HTTP.
B=1/2
It refers to the transmission mode, wherein 1 means timed upload and 2 means re-upload.
C=1–10 (TCP)/10–100 (HTTP)
It refers to the sampling rate and the unit is samples per second. The default value 6 samples
per second for transmission over TCP and 100 samples per second for transmission over
HTTP.
D=1–60
It refers to the time for timed upload and the unit is second. The time for timed upload over
TCP is 2s (unchangeable) and the time for timed upload over HTTP is 10s.

To initialize the G-sensor of the device, park your vehicle in a flat road and deliver this
command to the device.
A=2/4/8/16
It specifies the measuring range
A=Old password, which is required or the set will fail
B=New password, which should be 6 digits

View the device's firmware version


Restore the device to the factory settings, where all parameters are reset to the original
values. If your device is of the integrated edition, proceed with caution!
Restart the device once
Upload all logs in the device to Jimi log server.
A=IP address of the server
B=Port of the server
C=Device file path
Query the GPRS status, GSM status, GPS status, ACC status, and the network mode of the
device.
Query the IMEI, location mode, and time zone of the device
A=ON/OFF; M=10
ON: Enable the ping; OFF: Disable the ping
M: The minimum time interval is 10s
This command is used to format the memory card of the device.
Note: All data will be cleared!
A=0/1; Whether to record audio while recording the video (input a number)
0-Off, 1-On
A=1/2; It defines which camera will be configured with an independent switch (input a
number).
1-Main camera, 2-Sub camera
B=0/1; It is the switch to control the selected camera.
0-Disable, 1-Enable
A=Whether to enable the mirroring of the backup camera (rear-view)
ON/OFF

A=IN/OUT
It refers to the camera channel that streams the video, wherein IN refers to the main camera
and OUT the subcamera.
B=0/90/180/270 degrees
It refers to the angle of rotation, wherein: 0: No rotation
90: 90° rotation
180: 180° rotation
270: 270° rotation

A=0/1; It defines the resolution of the videos captured by the front camera.
0=1920x1080, bitrate 8M
1=1280x720, bitrate 4M
A=0/1
It refers to the unit of the speed, wherein "0" refers to "km/h" and "1" "mph".

A=0/1/2/3, wherein "0" means off, "1" "JIMI", "2" "TruckXInc", and "3" "Creare Sistems".
It indicates whether to display the company name at the lower right corner of the video.

A=ON/OFF
It is a switch used to specify whether the device will auto upload a location packet to notify the
user every time the ACC status changes.

A=ON/OFF; Whether to enable auto upload of location packets


ON: The device will auto upload location packets at a preset interval after it enters ACC ON
mode;
OFF: The device will upload location packets only when the speed of the vehicle is greater
than 3km/h.

B=1–600; It defines the upload interval.


The unit is second (s) and the default value is 10

A=ON/OFF
B=angle,5~45, default is 10
A=ON/OFF
It is a function switch. When A is set to "ON", the device will re-upload a location packet every
time an event is triggered.
Query the location and alert packets that are cached in the device and have not been
uploaded
A=Event type (input the codes of different types of events, see the attachment for details)
B=1–60; It defines the time interval to trigger a same-type event after the last one (input a
value)
The unit is minute (min) and the default value is 5
A=Event type (input the event code of an event type)
B=ON/OFF
It indicates whether to upload event videos automatically or on demand.
A=Event type (input the event code of an event type)
B=ON/OFF; Enable/Disable the alert tone
A=10/15/30/60, default is 7
It indicates the length of a video captured before an event is triggered when the device is ACC
ON. The unit is second.
B=10/15/20/30/60, default is 15
It indicates the total length of a video captured before and after an event is triggered. The unit
is second.

A=0/1; It indicates the battery type (input a number)


0: 12V, 1: 24V
B=Voltage value to trigger an undervoltage alert (input a value)
Value range for 12V vehicles: 90–130V, wherein 90V indicates the undervoltage alert value is
9V; therefore if you set the value to a multiple of 10, do not forget the "0". Default: 118V
Value range for 24V vehicles: 180–255V, wherein 180V indicates the undervoltage alert value
is 18V; therefore if you set the value to a multiple of 10, do not forget the "0"; Default: 230V

A=ON/OFF B=4–12 (hours), default is 4


It specifies the duration when the device is ACC ON (this parameter is used to determine
whether a driver is fatigued and this event will be triggered only once).
C=1–30 (minutes) , default is 5
It specifies the interval to trigger another fatigue driving alert after a same event is triggered
when the device continues to be operated in ACC ON mode

A=ON/OFF; Whether to enable the speed alert feature;


T=5–600; The duration during which the device detects the speed of the vehicle is always
above a set trigger value; The unit is second (s) and the default value is 10.
S=1–255; Trigger speed, at which the device will generate a speed alert; Default: 80km/h
M=0–3, Report mode of speed alerts, wherein "M" is set to "2" by default.
0: Platform, 1: SMS+Platform, 2: Platform+SMS+Call, 3: Platform+Call

A=ON/OFF
Function switch, wherein the device will alert once an SOS event is triggered
B=Report mode of alerts
0: GPRS, 1: SMS+GPRS, 2: GPRS+SMS+Call, 3: GPRS+Call
A=SOS number 1 to add
B=SOS number 2 to add
C=SOS number 3 to add
Delete one or multiple SOS numbers by their number sequences.

A=1/2/3. It specifies the cyclic dialing count; default: 2

A=ON/OFF; Default: ON
B=1/2/3; It refers to the trigger sensitivity; 1: Low, 2: Mid, 3: High; Default: 2

A=ON/OFF; Whether to enable the defense mode

T=1–30; It refers to the delay time; The unit is minute (min) and the default value is 5

A=1–255. It specifies the sensitivity range, wherein the lower the value, the more sensitive the
vehicle to detect a vibration.
This command is the same as the SENALM command, but it is more specific.
A=10–600 (seconds).
It refers to the time during which a vibrating alert won't be triggered if the device is ACC ON
during that time.
A=ON/OFF. It specifies whether to enable the feature to trigger an alert when the memory
card is inserted or removed.
B=0–3. It specifies the alert mode. Default: 2.
A=ON/OFF; Default: ON
M=1/2/3; It refers to the trigger sensitivity; 1: Low, 2: Mid, 3: High; Default: 2

A=1–255 (the lower the value, the more sensitive the device to sense a collision)

A=0/1/2/3; It defines the sensitivity to trigger such an alert


0-Off, 1-Low, 2-Mid, 3-High
A=0/1/2/3; It defines the sensitivity to trigger such an alert
0-Off, 1-Low, 2-Mid, 3-High
A=0/1/2/3; It defines the sensitivity to trigger such an alert
0-Off, 1-Low, 2-Mid, 3-High
A=1–255. It specifies the threshold to trigger a harsh acceleration alert.
B=1–255. It specifies the threshold to trigger a harsh braking alert.
C=1–255. It specifies the threshold to trigger a harsh cornering alert.

A=ON/OFF. It defines whether to enable timed image taking.


B=30–300 (seconds). It specifies the length of the timer. Default: 30.
C=1–3. It specifies how many times will the device take images during one trigger. Default: 1.

It is used to query the size of images in the device that are taken via this feature.

It is used to delete all images taken via this feature.

A=0/1; Whether to cut off the fuel/power (input a number)


0: Connect fuel/power, 1: Cut fuel/power
A=ON/OFF
An accessory is required to be connected to use this feature.
A=ON/OFF (an accessory is required to be connected to use this feature)
A, B, C, and X refer to permission levels to set. They may be digits or letters.
The levels are separated by commas (,). You can set up to 10 permission levels for the card
reader at a time.

A=0/1/2/3.
It refers to the interface for user identification, wherein "0" means the switch is "off", "1"
refers to the "card reader", "2" refers to "RFID", and "3" refers to "facial recognition".

A=0–60 (min). It refers to the interval to collect fuel level data when the vehicle is ACC OFF
and the value "0" indicates the sensor will not collect data.
B=0–60 (min). It refers to the interval to collect fuel level data when the vehicle is ACC ON and
the value "0" indicates the sensor will not collect data.
C=1–10000. It refers to the difference between the fuel level data collected before and after
the vehicle is ACC OFF, at which value a fuel exception alert will be triggered. The accuracy is
"0.01".
D=1–10000. It refers to the difference between the fuel level data collected before and after
the vehicle is ACC ON, at which value a fuel exception alert will be triggered. The accuracy is
"0.01".
For example: If the value is set to "1000", the corresponding value is 10 (1000*0.01), which
means an alert will be triggered if the difference between two measurements is greater than
10%. The default value is "1000".

A=0/1. It refers to the fuel level sensor to set. The device supports two fuel level sensors: A
and B.
0: Fuel level sensor A; 1: Fuel level sensor B
B=0–254.
It refers to the ID of the fuel level sensor to set (The IDs for the two fuel level sensors should
be set differently)
If no parameters are specified in a query command, the device will return the data of the two
fuel level sensors.

A: It refers to the collection interval when the vehicle is ACC ON.


B: It refers to the collection interval when the vehicle is ACC OFF.
Value range: 0–60 (min)
Default: 0, which means temperature data will not be collected.
It is used to change the format of the temperature data to 3C.

A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
Set a period during which the device will not repeatedly give out voice announcements for the
same type of events.
Default=5s [The unit is second (s), wherein you can set the report interval to "0" to always
disable the voice announcement or to 10, 30, or 60].

A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
Set a period during which the device will not repeatedly send alert messages of the same type
of events to the platform.
Default=120s [The unit is second (s), wherein you can set the report interval to "0" so the
device will never upload the alert messages to the platform or to 180, 600, or 1800]

A=0/1
0: End
1: Start

A=0–120
This parameter, once successfully set, becomes invalid after the device re-enters ACC OFF.

A=Eyes closed
B=Yawning
C=Distracted/head low
D=Smoking
E=Calling
F=No face detected
It is used to specify the duration during which the device continues to detect a bad behavior of
the driver before an event is triggered.
Default=3s [The unit is second (s) and the value range is 1–10].

A=1–10. It indicates after how many alignment exceptions will the device generate a relevant
alert. If A is set to "0", the feature is disabled.
B=0/1 (1: On, 0: Off ); Whether to notify the user via sound upon an alignment exception.
C=0/1, wherein "0" indicates do not upload and "1" indicates upload. It is used to set whether
to upload alignment exception messages to the platform.

A=HTTP address.
Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.

A=1–10. It specifies the retry count. Default: 5.


B=1–30 (minutes). It specifies the interval between each retry. Default: 3.

A=URL to receive history videos


M=0/1. It refers to the address type, wherein "0" refers to "IP" and "1" "domain name".
A=Server address (IP or domain name)
P=Server port
The device will restart after the address of the TCP server is changed.
Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.

"Address" refers to the address of the RTMP server.


Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.

A=0/1. It refers to the working logic, wherein "0" refers to the integrated version and "1" the
distributed version.
Note: Before switching the device to the integrated version, you must first do the followings in
the strict order: switch the working logic, modify the addresses of HTTP and RTMP servers,
and modify the address of the TCP server.

Get the images taken by the inward camera from the device.

Get the images taken by the front camera from the device.

Get the images taken by the inward and front cameras from the device.

N=3–10. The unit is second.


Get a video (H.264) that is Ns long and taken by the inward camera.

N=3–10. The unit is second.


Get a video (H.264) that is Ns long and taken by the front camera.

N=3–10. The unit is second.


Get a video (H.264) that is Ns long and taken by the front camera.

A=ON/OFF. ON means to enable RTMP streaming; while OFF means to stop RTMP
streaming.
B: IN/OUT. IN refers to the inward camera and OUT the front camera. The default value is IN.

It is used to set the login information for real-time video.


The “Account number” is “jimi” by default.
The “Password” is “88888888” by default.
A=The name of the file to upload (format: Year_Month_Day_Hour_Minute_Second)
B=1/2 (1=Front camera; 2=Inward camera)
A=The event to generate (Format=Year-Month-Day Hour:Minute:Second)
B=1/2 (1=Front camera; 2=Inward camera)
C=10–60 (seconds). It refers to the video length. Default: 15s.

A=The name of the file to upload

It is used to get the main information of the device via wifikit, wherein the information includes
(the name of the project/device IMEI/free space and total space of the SD card/software
version/hardware version/the number of satellites that have been engaged in
positioning/network signal)
APN#unim2m.gzm2mapn#unim2
m.gzm2mapn

ROAMING,ON

WIFIAP,ON,ABCD,12345678

BTNAME,ON

VOLUME,2

VOICESW,1

LED,ON

TIMESYNC,gps

TIMEZONE,+08:00

GTRANS,2,2,100,10

RANGE,2

PASSWORD,123456
LOG,106.53.71.26,60108,/
sdcard/C28Log

PING,HTTP

RECORDAUDIO,0

RECIRDSW,1,1

MIRROR,in,OFF

RATATION,IN,90

VIDEORESOLUTION,0

MILE,0

LOGOSW,0

ACCREP,OFF

TIMER,ON,10

ANGLEREP,ON,15

EVENTGPS,OFF

VIBRATE PHONECALLING
OVERSPEED SHELTER
RAPIDACC RELAYOFF
RAPIDDEC RELAYRECOVERY
FILTER,CRASH,5 RAPIDTURN MISSINGFACE
DRIVE NOSDCARD
DRIVE NOSDCARD
POWER SDCARDMOUNT
UPLOADSW,CRASH,ON VOLTAGELOW OIL
CLOSEEYES OILTO
ALARMTONE,CRASH,ON YAWN TEMPTO

VIDEOPARAM,7,15

EXBATALM,0,115

FATIGUE,ON,4,5

SPEED,ON,10,90,1

SOSALM,ON,1

SOS,A,123456789
SOS,D,123456789

CALL,2

SENALM,ON,2
DEFENSE,ON

DEFENSE_TIME,5

SHOCK,10

SHAKEDELAY,60

NOSDCARDALM,ON,2
CRASHALM,ON,2

SENSOR,255

RAPIDACC,ON,2

RAPIDADEC,ON,2

RAPIDTURN,ON,2

RAPIDTEST,30,40,70

PICTIMER,ON,300,1

RELAY,1

SPEEDOMETER,ON
CARDREADER,ON

EXDEVICESW,1

OILPARAM,1,1,1000,1000

OILIDSET,0,01

TEMPCOLLECTINTERVAL,1,1
DMS_VOICE_CUSTOM,10,10,10
,10,10,10

DMS_ALERT_CUSTOM,180,180,
180,180,180,180

DMSCALIBRAT,1

DMS_VIRTUAL_SPEED,30

DMS_CONTINUITY,3,3,3,3,3,3

DMS_CALIB_ABNORMAL,3,1,0

UPLOAD,http://www.baidu.com/
upload

HTTPUPLOADLIMIT,5,3

FILELIST,http://www.baidu.com
SERVER,1,dvrdev.tracksolidpro.c
om,21100

RSERVICE,192.168.0.1:1935/live

COREKITSW,0

Picture,in

Picture,out

Picture,inout

Video,in,3s

Video,out,3s

Video,inout,3s

RTMP,ON,OUT

RLOGIN,jimi,88888888
HVIDEO,2020_01_01_24_05_06,
1

EVIDEO,2020-06-15 12:12:12,1
UPLOADFILE,EVENT_35773009
0564767_00000000_2021_01_29
_07_28_18_F_05.mp4