CT6839A Instruction: Warning Code Meaning Description

The CT6839A is a motor protection device that includes features such as current detection, overload protection, phase loss protection, and temperature control. It operates within a temperature range of -50 to 150 °C and supports various settings for overload action time, three-phase unbalance, and self-recovery functions. The device also includes a password protection feature to prevent unauthorized changes to its parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views4 pages

CT6839A Instruction: Warning Code Meaning Description

The CT6839A is a motor protection device that includes features such as current detection, overload protection, phase loss protection, and temperature control. It operates within a temperature range of -50 to 150 °C and supports various settings for overload action time, three-phase unbalance, and self-recovery functions. The device also includes a password protection feature to prevent unauthorized changes to its parameters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

CTDS-CT6839A

CT6839A Instruction Version No.: h170113


Warning
Meaning Description
code

一、 Main functions A11 Oil warning The oil switch closes


Current detection, motor overload protection, phase loss protection; Water temperature detection, "Overload" will be displayed at the bottom of the display at the
A12 Overload
water pump control; Oil detection, oil lacking protection; accumulated working time checking. same time
"Open-Phase " will be displayed at the bottom of the display at
A13 Phase loss the same time
二、 Technical indicators
⚫ Temperature range: -50~150 ℃ (resolution 0.1 ℃) Three-phase
A14
unbalance
⚫ Power & voltage: 220V ± 10% or 380V ± 10%, refer to the product label for details
The temperature sensor is disconnected or short-circuited
⚫ Usage environment: Temperature -30 ℃~80 ℃, humidity ≤ 85%, no condensation Temperature
A21 (temperature display "OPE" or "SHr") and the compressor will
sensor faulty
⚫ Output contact capacity: 8A/250VAC (pure resistive load) not turn off
⚫ Temperature sensor: NTC R25=5k Ω, B=3470K High
A31 temperature
warning
三、 Instructions If the F87 parameter has been set, this warning will be
Maintenance generated when the cumulative working time of the compressor
A99
Period exceeds the set time, which causes the compressor stop
⚫ Check the three-phase current of A, B and C working.
The three-phase average current of the compressor will be displayed when it is working
normally, and the three-phase current of A, B, and C can be switched by pressing the "S" button. The ⚫ Warning restore
current flashes when overload, underload, open-phase, three-phase unbalance and other faults occur, You can press the "M" button to manually recover when the compressor is overload, open-phase
which indicates that this is the current locked at the moment of the fault (the compressor has been and three-phase unbalance warnings occur, the controller locked in the warning state. (Available
powered off, and the actual current is 0). parameters F51-F53 are set to auto-resume)

⚫ Check the temperature ⚫ More operations


Press and hold the “” button to display the temperature, and release it to the current display Press and hold the "M" key for 5 seconds to enter the parameter setting state, if the password has
state. been set, the word "PAS" will be displayed to prompt you to enter the password, use the “” key to
enter the password, if the password is correct, the parameter code will be displayed, use the “” key
⚫ Check the cumulative operating time of the compressor to select the parameter code, press the "S" key after selecting a code to display the corresponding
Press and hold the “” button to accumulate the working time of the compressor in hours,
and release it to the current display state. parameter value of the code, then use the“” key to set the parameter value, and then press the "S"
key after the setting is completed, back to the state of displaying the parameter code. Press the "M" key
⚫ Compressor rated current value setting to exit the parameter setting state when the parameter code is displayed, and press the "M" key to
Press the "S" key for 2 seconds, the digital display will show "Setting," use the “” or “”key to indicate abandonment during the parameter value setting, and exit without changing the parameter
change the setting value (holding the “” or“” key allows continuous adjustment), and please press value。
the "S" key to exit the setting mode after setting.
The following table lists the parameter codes:
⚫ Warning display
The words "overload" and "phase loss" will be displayed on the display screen when Compressor Parameter Setting Original Measure
Category Code Remark
overload and open-phase; Other warnings are displayed in the form of codes, as shown in the following description range settings ment
table:

1
CTDS-CT6839A

This parameter can be The compressor will


Motor rated
1.0 – set directly by be turned off when
F11 current(setting 45 A High
100 pressing and holding high warning has been
current) F43 temperature 0 - 150 95.0 ℃
the Sel button generated( at the time
warning
Overload 0.1 – Adjustable overload the temperature has
F13 5 Second
action time 60.0 time reaches to 95℃)
Three-phase After powering on for
F21 unbalance 1 – 50 20 % a few seconds, the
Compressor
action point Power-on relay is attracted,
protection F61 0 – 999 0 Second
Three-phase 0.1 – The warning function delay which is equivalent to
F22 unbalance 60.0 5.0 Second of open-phase or a timing relay
action time OFF three-phase unbalance function
OFF indicates that
will be disabled if the
OFF there is no password
0.1 – operation time of F80 Password 0001 -- OFF - If you set it to 0000,
Lack-phase 9999 the password will be
F23 60.0 2.0 Second open-phase or
action time cleared
OFF three-phase unbalance
Displays the
has been set to "OFF",
compressor’s
Additional F85 - - Hour
Self-restore cumulative
F51 0 - 10 1 Times Functional
times operating time
The interval Clears the
between 0.1 – compressor’s YES/N YES: Clear
F52 15.0 Minute If F51 is set to 0, F86 NO -
automatic 99.9 cumulative O NO: Do not clear
Auto-recovery automatic recovery is
recovery operating time
not allowed
The interval When the compressor
exceeds this time, the
between
F53 1 - 999 60 Minute compressor will stop
repeating OFF working and the
Maintenance
F87 1 -- OFF Hour warning code "A99"
failures Period
9999 will be displayed.
Turning on the OFF means that there
is no time limit for the
Highest cooling water pump maintenance period
F41 0 - 150 70 ℃
temperature when the temperature Displays the
Temperature exceeds 70℃. product model
control Turning off the F90 -
and version
Lowest cooling water pump Test
F42 0 - 150 60 ℃ number
temperature when the temperature Manufacturer
drops below 60℃. F91 -
reserved

2
CTDS-CT6839A

Manufacturer The purpose of the auto-recovery function is to provide an opportunity of self-restore in the event
F92 - of a fail-safe shutdown and to prevent unattended equipment from being shut down for a long time due
reserved
to occasional failures. You can freely set the self-restore with parameters F51, F52, and F53. For
Manufacturer
F99 - example, F51=3, F52=15, F53=60, which effects are: after the fault is stopped, it will automatically
reserved restore after 15 minutes (F52=15), and it can be retried 3 times (F51=3). The machine will be locked in
Exit the the shutdown state and needs to be manually recovered if the fault has repeated more than 3 times, and
End -
setting state the interval between repeated failures is less than 60 minutes (F53=60).
This function is set to OFF by default, and it needs to be safe when using it, and there is no impact
四、 Basic working principle on Stardelta when self-restore.

⚫ Current sensing ⚫ Power-on delay function


Since the protector detects the three-phase load current through an external current transformer, If the timing relay function is enabled by setting the parameter F61, the relay will not immediately
the three phase wires of the protected motor must pass through the three holes of the current attracted after the protector is energized, but attracted again after a period of delay. The delay time can
transformer. The underload, three-phase unbalance, and open-phase detection will not be carried out be set by the parameter F61, and the countdown will be displayed on the display. This is equivalent to a
under the circumstance of low load current to prevent malfunction in the power-off state of the motor. time-lapse start time relay function.

⚫ Overload protection ⚫ Temperature control


When the load current exceeds the rated current (parameter F11) and the duration reaches the set The temperature control point is determined by two parameters: "Upper Temperature Limit (F41)"
overload action time (parameter F13), the relay will disconnect and the power supply to the motor and "Lower Temperature Limit (F42)". Start the pump when the temperature perceived on the
should be cut off. temperature probe exceeds the "upper temperature limit" and stop the pump until the temperature lower
than the "lower temperature limit".
⚫ Three-phase unbalance protection
The three-phase unbalance rate is defined as the absolute value of the difference between any ⚫ Trial time
phase current and the three-phase average current, taking the maximum value and dividing it by the You can set a trial time (parameter F87), the controller will accumulate working time after
three-phase average current. powering on. The controller will stop working when the cumulative working time exceeds the trial
When the three-phase unbalance rate is greater than the set three-phase unbalance action point time, at which the warning code A99 will be displayed. There are two methods to remove the trial time
(parameter F21) and the duration is greater than the three-phase unbalance action time (parameter F22), limit. First, you can set the parameter F87 to "OFF". Second, you can clear the cumulative working
the relay will disconnect and the motor power supply should be cut off. time and start the trial again by using the parameter F86. Parameter F85 can view the cumulative
working time of the controller (hours).
⚫ Lack-phase protection
Lack-phase can be considered as a serious three-phase unbalance, it is considered to be lack-phase ⚫ Password
when the three-phase imbalance rate exceeds 50%. The lack-phase action time (F23) is generally set In order to prevent irrelevant personnel from changing the controller parameters, you can set a
shorter than the three-phase unbalance operating time (parameter F22). password (parameter F80) on the condition that you must input the correct password to set the
parameters. If a password has been set by F80, each time you press and hold the "M" key to enter the
setting state, at which you are prompted to input the password. If you don't need a password, you can
set F80 to "OFF".
Note: You are not able to use the setting state if you forget the password. Therefore, you must
remember that after setting the password.

⚫ Self-restore

3
CTDS-CT6839A