CT6839A Instruction: Warning Code Meaning Description
CT6839A Instruction: Warning Code Meaning Description
1
CTDS-CT6839A
2
CTDS-CT6839A
Manufacturer The purpose of the auto-recovery function is to provide an opportunity of self-restore in the event
F92 - of a fail-safe shutdown and to prevent unattended equipment from being shut down for a long time due
reserved
to occasional failures. You can freely set the self-restore with parameters F51, F52, and F53. For
Manufacturer
F99 - example, F51=3, F52=15, F53=60, which effects are: after the fault is stopped, it will automatically
reserved restore after 15 minutes (F52=15), and it can be retried 3 times (F51=3). The machine will be locked in
Exit the the shutdown state and needs to be manually recovered if the fault has repeated more than 3 times, and
End -
setting state the interval between repeated failures is less than 60 minutes (F53=60).
This function is set to OFF by default, and it needs to be safe when using it, and there is no impact
四、 Basic working principle on Stardelta when self-restore.
⚫ Self-restore
3
CTDS-CT6839A
五、 Wiring diagram