monitoring parameters
monitoring parameters
Real Time Monitoring and Advance Control - Remote Monitoring and Control
- Insulation Life Estimation
- Overload Capacity
- Bubbling Temperature
- Moisture in Insulation
- Real time Alarm and Notifications
Direct Winding Hot Spot - Easy Integration
- HV Winding
- LV Winding
- MV Winding
- Core Hot Spot
OLTC Monitoring
Dissolved Gas analyzer Integration - Tap Position
- Single gas DGA - Motor Current / Voltage
- Multi-gas DGA - Motor Torque
- Moisture - Power Consumption
- Oil Temperature
- Level Partial Discharge
02 03 - Dissolved Gases
R501 SYSTEM
ARCHITECTURE
R501
Hardwired (Analog/Digitals)
Serial (RS-485) or Ethernet (TCP/IP)
Fiber Optic Extensions Modbus, DNP3.0, IEC60870-104, IEC61850
Hardwired (Analog/Digitals)
1 2 3 4 5 6 7 8
Sensors on Fiber Optic Transformer Sensor on Dissolved Bushing & Partial Discharge
Cooling Control
Transformer Temperature Control Cubicle OLTC/RTCC Gas Analyzers PD Monitor Monitor
Certifications
1. OTI,WTI, RTD, PRD, Breather, Buchholz
- ATEX
Relay, LLG/OLI, Pressure Sensor etc.
- Lloyds
2. Direct winding Hot Spot Monitor - CE / RoHs
1
7
3. Transformer Control Cubicle 1
3
4. OLTC and RTCC Panel 8
1 2
5. Cooling System and Control Cabinet Variants
6. Dissolved Gas Analyzer
5
1 - Offshore / Marine
7. Bushing Monitoring
4 6
- Ethernet Redundancy: PRP
8. Partial Discharge Monitor
- Enterprise Monitoring Software
5
04 05
R501 FEATURES RUGGED CONNECT
Comprehensive Features to Meet Market Demand - Web-server based software
- Secure access to data & Configuration
- Advance Data Integration Protocols
- Modbus, DNP3.0, IEC61850
RELAY OUTPUT MODULE - Multiple Language Support
-Up to 08 Form C Relays - Lifetime Consumption
-Dry contact (NO-C-NC) - Insulation Aging
ANALOG OUTPUT
-User Programmable - Winding Hot Spot Calculation
- Up to Analog output - -Built-in LED indicators - Cooling System Efficiency
DC Current Loop
- (4-20mA / 0-1mA)
- Dc Voltage (0-5V / 0-10V)
- User Programmable
- Built-in LED indicators
Remote /
Integrated Display
CPU MODULE FIBER OPTIC MODULE ANALOG INPUT MODULE DIGITAL INPUT MODULE
- Data storage and visualization - 02, 04, 06 and 08 Channels - Up to channels - Up to 1 channels
- 02 x Serial (RS485) ports - GaAs (200u and 62.5u) Module - AC/DC current input - Up to 250Vdc input V
- 02 x Ethernet (PRP support) - Fluro Module - AC/DC voltage input - Threshold Voltage > 60V
- System Fault Relay - Built-in LED indicators - RTD / Potentiometer - Built-in LED indicators
- Remote Display - Built-in LED indicators
06 07
TECHNICAL SPECIFICATIONS
POWER SUPPLY Input Power Requirement 24V DC ( Default), Optional USB powered Operating Temperature -40 to 72 °C
Data Storage Capacity MicroSD external memory slot (up to 2 TB) Operating Humidity 95% Non Condensing
CPU ENVIRONMENTAL
Logging Rate 1 sec interval on USB Storage Temperature -40 to 85 °C
MODULE AND MECHANICAL
Config port USB (to use with Rugged connect windows software) Dimensions W26.7 cm x H7.2 cm x D18.7 cm (10.5’’ x 2.8” x 7.4”)
SYSTEM Expandable to 256 Channels, Daisy chain up to 32 units Weight App. 5Kg. (for complete filled Chassis)
Maximum number of Channels
CAPACITY (with Modbus, Canbus)
OUTPUT RELAY
# of Output Channels 8 Form C relays
MODULE
Ethernet Ports (RJ-45 & FO Ethernet) Modbus, DNP3.0, IEC 60870-5-104, IEC61850
COMMUNICATION
Serail Port RS485 with Modbus support
OPTIONS
CANBUS Port CANBUS Master/Slave support for Can Dataloggers
Conducted & Radiated Emissions ICES-003 (2016), CISPR32 (2015), CISPR11 (2015)
ORDERING CODE
Ripple, Dips & Damped Oscillatory IEC61000-4-17, IEC61000-4-18, IEC61000-4-29
08 09