0% found this document useful (0 votes)
11 views25 pages

Xeaprogrammimgmanual 206

This programming manual provides instructions for the XE-A206 electronic cash register, focusing on lead-free solder usage and programming procedures. It includes details on master and program resetting, as well as guidelines for soldering with lead-free materials. The manual is intended for after-sales service and is subject to change without notice.

Uploaded by

rbasso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views25 pages

Xeaprogrammimgmanual 206

This programming manual provides instructions for the XE-A206 electronic cash register, focusing on lead-free solder usage and programming procedures. It includes details on master and program resetting, as well as guidelines for soldering with lead-free materials. The manual is intended for after-sales service and is subject to change without notice.

Uploaded by

rbasso
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 25

PROGRAMMING MANUAL

CODE : 00Z XEA206UPME

LEAD-FREE SOLDER MODEL

ELECTRONIC
CASH REGISTER

MODEL XE-A206
(“U” version)

CONTENTS

■ LEAD-FREE SOLDER

CHAPTER 1. MASTER RESET AND PROGRAM RESET . . . . . . 1 - 1

CHAPTER 2. PROGRAM MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1

CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE. . . . . . . . . . . . . . . . . . 3 - 1

Parts marked with "!" are important for maintaining the safety of the set. Be sure to replace these parts with specified
ones for maintaining the safety and performance of the set.

This document has been published to be used


for after sales service only.
The contents are subject to change without notice.
■ LEAD-FREE SOLDER
The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The
alphabet following the “LF” mark shows the kind of lead-free solder.
Example:
<Solder composition code of lead-free solder>

Solder composition Solder composition Solder composition code


code (Refer to the Sn-Ag-Cu a
Lead-Free table at the right.)
Sn-Ag-Bi
b
Sn-Ag-Bi-Cu
Sn-Zn-Bi z
5mm
a Sn-In-Ag-Bi
Sn-Cu-Ni
Sn-Ag-Sb
n
i

s
Bi-Sn-Ag-P p
Bi-Sn-Ag

(1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD


When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident.
Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is rec-
ommendable.

(2) NOTE FOR SOLDERING WORK


Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to
conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive tem-
perature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed.
Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently.
If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after com-
pletion of soldering work.
If the soldering iron tip is discolored black during soldering work, clean
and file the tip with steel wool or a fine filer.

XE-A206 LEAD-FREE SOLDER


CHAPTER 1. MASTER RESET AND PROGRAM RESET

1. MASTER RESETTING
Master resetting clears the entire memory and resumes initial values.

Master resetting can be accomplished by using the following procedure:

Procedure :

1) Unplug the AC cord from the wall outlet, or set the mode switch to OFF position.
2) Let the ECR be witout the memory backup battery.
3) Wait over 1 minute for discharging.
4) Set the mode switch to any position except OFF.
5) Plugin the AC cord to the wall outlet, or turn the mode switch from OFF position to another position.
The master reset can also be accomplished in the following case.

In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power
has been restored.
(This is because if power failure occurs with no battery attached to the machine, all the memories are lost and the machine does not work properly
after power recovery; this requires the master reset operation.)

2. PROGRAM RESETTING (INITIALIZATION)


This resetting resumes the initial program without clearing memory.

This resetting can be operated at below sequence in PGM mode.

Procedure:

1) Unplug the AC cord from the wall outlet.


2) Wait over 1 minute for discharging.

3) Set the mode switch to the PGM position.

4) While holding down the FEED key, plugin the AC cord to the wall outlet.

Note: In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the
power has been restored.

XE-A206 MASTER RESET AND PROGRAM RESET

1–1
CHAPTER 2. PROGRAM MODE

1. READING STORED PROGRAMS


The machine allows you to read every program stored in the PGM mode.

■ Key sequence for reading stored program


Report name Key sequence
Programming report 1 CA/AT
Programming report 2 2 3 CA/AT
[Auto] key programming report 1 3 CA/AT
Printer density programming report 3 3 CA/AT
PLU programming report (*1) Start PLU code @/FOR End PLU code PLU

(*1) PLU code range can be specified by entering the start and end numbers according to the following procedure.
When specifying a single time interval, PLU code, the start number has only to be entered.

■ SAMPLE PRINTOUTS
1. Programming report 1

F 44 CASH FUNCTION NO. /TEXT


HEADER 008 /PROGRAM (*3)
DATE/TIME/CLERK NO F 45 CHECKxxx FUNCTION NO. /TEXT
008 /PROGRAM (*3)
05/02/2006 12:34PM 01 MACHINE NO. /CC-NO. / F 46 CHRAGExx FUNCTION NO. /TEXT
123456#1234 BETTY___ CLERK NAME 008 /PROGRAM (*3)
MODE TITLE F 47 CHARGE-
*PGM* F 48 CONV 1 00 FUNCTION NO. /TEXT/PROGRAM (*4)
DEPT CODE/TAXABLE/ AAAA 9999.9999 CURRENCY SYMBOL/RATE
D01 T1234 073
PROGRAM (*1) F 49 CONV 2
DPT.01xxxxxx -1234.56
TEXT/PRICE WITH SIGN F 50 ****CID
D02 T1234 073 :
DPT.02 -1234.56
: F 67 COPY
: F 68 EJ
D99 T1234 071 (MAX department is decided by F 69 EJ END FUNCTION NO. /TEXT
DPT.99 0.00 PGM selection.) YOUR LOGO TEXT
RECE I PT (It is according with LOGOFORMAT.)
FUNCTION NO. /TEXT/PROGRAM (*2)
F01 ( - ) xx 007 THANK YOU
-1000.00 AMOUNT WITH SIGN PLEASE
F02 % 1xxxx 000 FUNCTION NO. /TEXT /PROGRAM (*2) VI S I T
L100.00% T1234 -10.00% HALO WITHOUT SIGN/ US AGA I N
F04 NET1 RATE WITH SIGN
#5 00000000 (JOB# 5) FUNCTION SELECT
F05 TAX1 ST FUNCTION NO./TEXT
F06 GRS TAX1 #6 00000000 (JOB# 6) PRINT FUNCTION
F07 RFD TAX1 #7 00000000 (JOB# 7) RECEIPT PRINT FORMAT
F08 TAX1 #10 0000 (JOB#10) POWER SAVING PROGRAMMING
F09 TX1 EXPT #11 0 (JOB#11) LOGO FORMAT
: #15 00000000 (JOB#15) FUNCTION SELECT2
: #19 00 (JOB#19) DOUGHNUT TAX EXEMPT
F25 GRS MTAX #35 007 (JOB#35) ONLINE Timeout time
F26 RFD MTAX #50 007 (JOB#50) Thermal printer density
F27 M-TAX 7 FUNCTION NO. /TEXT /HALO T1 10.0000% TAX1 RATE
F28 GST EXPT / 1.00 CYCLE
: 1 0.11 TAX /BREAK POINT AMOUNT
: 2 0.23
F40 ***RAxxx 9 3 0.57
FUNCTION NO. /TEXT /HALO 4 0.78
F41 ***POxxx 9
5 1.11
F42 TRANS CT
T2 4.0000% TAX2 RATE
F43 NET3 0.10 LOWER TAX LIMIT
T3 5.0000% TAX3
0.20
T4 ------ TAX4 ("------": INHIBIT)
C#01 CLERK.01 Clerk No. /Clerk name
C#02 CLERK.02
: :
: VARIOUS PROGRAM
C#25 CLERK.25
Refer to the programming section
about the data of each JOB.

XE-A206 PROGRAM MODE

2–1
(*1) DEPT PROGRAM : ABC 2. Programming report 2
A: REGISTRATION TYPE A
NORMAL 0
SICS 1 HEADER
DATE/TIME/CLERK NO

B: LIMITATION DIGITS (*2) = 0 to 7 05/02/2006 12:34PM 01 MACHINE NO./CC-NO./


123456#1234 BETTY___ CLERK NAME
C: AMOUNT ENTRY TYPE C MODE TITLE
*PGM*
Inhibited 0 #61 00000000 (JOB#61) OTHERS1
#62 00000000 (JOB#62) OTHERS2
Open 1 #63 00000000 (JOB#63) OTHERS3
Preset 2 #64 00000000 (JOB#64) OTHERS4
#65 00000000 (JOB#65) OTHERS5
Open and Preset 3 #66 00000000 (JOB#66) OTHERS6
#67 00000000 (JOB#67) OTHERS7
#68 00000000 (JOB#68) OTHERS8
(*2) (-)/[%] PROGRAM : ABC #69 00000000 (JOB#69) OTHERS9
#70 00000000 (JOB#70) OTHERS10
A: ENTRY FOR ITEM A #71
GT2 $00000000000.00 GT2
ENABLE 0 #72
DISABLE 1 GT3 $00000000000.00 GT3
#76 Z1 0000 GENERAL Z1 RESET COUNTER
#77 Z2 0000 GENERAL Z2 RESET COUNTER
B: ENTRY FOR SBTL B #85 ___$ DOMESTIC CURRENCY SYMBOL
#86 00 TRAINING CLERK
ENABLE 0 #87 TRAINING TRAINING MODE TEXT
#88 0 LANGUAGE MODE
DISABLE 1 #90 0 (For the fixed messages)
#95 99
EJ/PLU MEMORY TYPE
C: LIMITATION DIGITS (for (-) key) = 0 to 7 (0 FIXED for [%n]) (0: TYPE, 1: TYPE2)
MAX NUBMER OF DEPT
(*3) MEDIA PROGRAM : ABC
: OTHERS PROGRAM
A: Footer print on Receipt A Refer to the programming section about the data of each JOB.

No 0
3. [Auto] key programming report
Yes 1

B: Entry of amount tenderd B


Non compulsory (Cash, check), 0 HEADER
Inhibit (Credit) DATE/TIME/CLERK NO
Compulsory 1 05/02/2006 12:34PM 01 MACHINE NO. /CC-NO. /
123456#1234 BETTY___ CLERK NAME
C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8
*PGM* MODE TITLE
#01
(*4) CONVERSION PROGRAM : AB KEY TEXT
1
A: OPEN RATE ENTRY A 0
0
ENABLE 0 0
CASH
DISABLE 1

B: PRESET RATE ENTRY B ------ DELETE (NO KEY)


ENABLE 0
DISABLE 1
4. Printer density report

HEADER
DATE/TIME/CLERK NO
05/02/2006 12:34PM 01 MACHINE NO. /CC-NO. /
123456#1234 BETTY___ CLERK NAME

*PGM* MODE TITLE


#01 50 Thermal printer density
10 : 0123456789AB Printing Sample
20 : 0123456789AB (Light & Shade value between
30 : 0123456789AB 10 to 90.)
40 : 0123456789AB
50 : 0123456789AB
60 : 0123456789AB
70 : 0123456789AB
80 : 0123456789AB
90 : 0123456789AB

XE-A206 PROGRAM MODE

2–2
5. PLU data report 2) DEPT FUNCTION PROGRAMMING
0

HEADER ABCDEFGH @/FOR DPTn CA/AT


DEPT SHIFT DPTn
05/02/2006 12:34PM 01 DATE/TIME/CLERK NO
0
123456#1234 BETTY___ MACHINE NO. /CC-NO. /CLERK NAME
MODE TITLE YY DEPT# ABCDEFGH @/FOR
*PGM*
START CODE/
0001-2000 END CODE (RANGE DATA)
P001 1
PLU001xxxxxx -1234.56 PLU CODE/Associated DEPT code/
YY: Department code (01 to 99)
: Type (*1)
: TEXT/PRICE WITH SIGN A: Taxable 4 A
NOTE : The deleted PLU is not printed.
No 0 ★
Yes 1

P001 ---- When PLU is deleted at the


B: Taxable 3 B
programming JOB.
No 0 ★
(*1) PROGRAM : Y Yes 1
Y: PROGRAM Y
SUBDEPT 0 C: Taxable 2 C

PLU 1 No 0 ★
Yes 1

D: Taxable 1 D
2. USER PROGRAMMING No 0
Yes 1 ★
1) PRICE PROGRAMMING FOR [DEPT.] & (-) KEYS
0 E: REGISTRATION TYPE A
NORMAL 0 ★
XXXXXX DPTn CA/AT
SICS 1
DEPT SHIFT DPTn
(-) F: SIGN B
0
YY DEPT# XXXXXX SBTL + 0 ★
- 1

YY: Department Code (01 to 99) G: LIMITATION DIGITS = 0 to 7


XXXXXX: Unit price (Max. 6digits) 0 : OPEN PRICE REGISTRATION INHIBIT.

If a price is set for a department which amount entry type is “INHIBIT” or H: AMOUNT ENTRY TYPE D
“OPEN”, its amount entry type is set as below automatically.
Inhibited 0
“PRESET” 1 “INHIBIT” Open 1 ★
“OPEN & PRESET” 1 “OPEN” Preset 2

MRS = 0 Open & Preset 3

MRS = 00010071
(TAXABLE 1, NORMAL, SIGN (+), HALO = 7, OPEN)

XE-A206 PROGRAM MODE

2–3
3) (-) & [%] KEY FUNCTION PROGRAMMING 5) PROGRAMMING FOR CONVERSION
0 0
(-)
ABCDEFGH @/FOR CA/AT AB @/FOR CONV CA/AT
%n

A: Taxable 4 A
A: OPEN RATE ENTRY A
No 0 ★
ENABLE 0 ★
Yes 1
DISABLE 1

B: Taxable 3 B
B: PRESET RATE ENTRY B
No 0 ★
ENABLE 0 ★
Yes 1
DISABLE 1
C: Taxable 2 C MRS = 00
No 0 ★
Yes 1 6) PROGRAMMING FOR FUNCTION KEYS
0 RA
D: Taxable 1 D
No 0 ★ A @/FOR PO CA/AT

Yes 1 TAX
(for Manual-TAX)
E: SIGN E
+ 0
A: LIMITATION DIGITS (0 = INHIBIT)
- 1 ★
= 0 to 7 (for Manual TAX)

F: ENTRY FOR ITEM F = 0 to 9 (for RA, PO)

ENABLE 0 ★ MRS = 7 (Manual TAX), 9 (RA, PO)


DISABLE 1
7) PROGRAMMING FOR MEDIA KEYS
G: ENTRY FOR SBTL G
([#/ST] key is used for programming of CASH.)
ENABLE 0 ★
0 CHK
DISABLE 1
ABC @/FOR CH CA/AT
H: LIMITATION DIGITS (for (-) key) = 0 to 7 #/ST
(for CASH)
0 : OPEN PRICE REGISTRATION INHIBIT (for (-) KEY)
0 : FIXED for [%]
MRS = 00001007 A: Footer print on Receipt A
(NON-TAXABLE, MINUS SIGN, ITEM&SBTL, HALO = 7)
No 0 ★
Yes 1
4) RATE PROGRAMMING FOR [%] AND
CONVERSION KEY. (0 FIXED for RA/PO)

0
B: Entry of amount tenderd B
%n
(RATE) CA/AT Non compulsory (Cash, Check), Inhibit (Credit) 0 ★
CONV
Compulsory 1
(0 FIXED for RA/PO)

(RATE): XXX.XX: Rate for % (0.00 to 100.00) C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8


XXXX.XXXX: Rate for CONVERSION (0.0000 to 9999.9999)
The DECIMAL POINT must be entered for setting the decimal digits. MRS = 008

MRS = 0.00 (%n)


0.0000 (CONVERSION)

XE-A206 PROGRAM MODE

2–4
8) DATA PROGRAMMING FOR PLU 11) PROGRAMMING OF DEPARTMENT TEXT
There are programmed by below key sequence. NO CHANGE
The PLU code is increment antomatically when one programming data
SBTL 1 DPTn (CHARACTERS) SBTL CA/TA
of a PLU is set.
And it is operated continuously until depressing the [CA/AT] key. DEPT SHIFT DPTn
The JOB is antomatically finalized when a maximum PLU code is XX DEPT#
programmed. DEPT CODE

(Basic programming sequence)


Basic operation consists of below 2 kinds.
XX: Department Code (1 to 99)
<Associate Dept & Price Entry> (CHATACTERS): CHARCTER (Max. 12 Characters)

Characters can be entered by using the character layout on keyboard or


XXXX PLU (DATA) DPTn CA/AT using numeric keys on keyboard.
PLU CODE DEPT SHIFT DPTn THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
DEPT CODE DEPT# (DATA) SBTL BY NUMERIC KEYS IS AS FOLLOWS:

(Code increment) YYY 3 [00] KEY


(Code entry) YYY: CHARACTER CODE (3 DIGITS)
(or [000] KEY ACCORDING TO PGM PRESET)
<Parameter data Entry>
MRS = DEPT. xx (xx: DEPT Code)
XXXX PLU (DATA) SBTL CA/AT
PLU CODE
(Code increment) 12) PROGRAMMING OF PLU TEXT
(Code entry)
NO CHANGE

SBTL 2 XXXX PLU (CHARACTERS) SBTL CA/AT


9) PROGRAMMING OF DEPARTMENTS TO BE PLU CODE
ASSOCIATED WITH PRICE PRESET
(Code increment)
PLU DELETE (INHIBIT)
(Code entry)
0

XXXX PLU YYYYYY DPTn CA/AT XXXX: PLU CODE (1 to 2000)


PLU CODE
DEPT SHIFT DPTn (CHARACTERS): CHARACTER (Max. 12 Characters)
0
Characters can be entered by using the character layout on keyboard or
ZZ DEPT# YYYYYY SBTL using numeric keys on keyboard.
DEPT CODE
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
(Code increment)
BY NUMERIC KEYS IS AS FOLLOWS:
(Code entry)
YYY3 [00] KEY
XXXX: PLU CODE (1 to 2000) YYY: CHARACTER CODE (3 DIGITS)
ZZ: DEPT CODE (1 to 99) (or [000] KEY ACCORDING TO PGM PRESET)
YYYYYY: UNIT PRICE (6 degits)
MRS = PLU.xxxx (xxxx: PLU code)
DELETE means to be set as a inhibited PLU in memory.
When it is assigned some DEPT for the inhibited (deleted) PLU, 13) PROGRAMMING OF FUNCTION TEXT
the PLU is set the MRS value except its price.
NO CHANGE
MRS = DEPT1, Price: 0 (Create: PLU001 to PLU2000) SBTL 3 @/FOR (CHARACTERS) SBTL CA/AT
XX

10) PROGRAMMING OF PLU/SUBDEPT


0
XX: FUNCTION CODE (Refer to the FUNCTION LIST)
XXXX PLU Y SBTL CA/AT
(CHARACTERS): CHARACTER (Max. 8 Characters)
PLU CODE

(Code entry) Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
XXXX: PLU CODE (1 to 2000)
BY NUMERIC KEYS IS AS FOLLOWS:
Y: 0 = SUBDEPT, 1 = PLU
MRS = 1 (PLU type) YYY 3 [00] KEY
YYY: CHARACTER CODE (3 DIGITS)
( or [000] KEY ACCORDING TO PGM PRESET)

MRS = Refer to the following table

XE-A206 PROGRAM MODE

2–5
■ FUNCTION LIST DEFAULT
F-NO. FUNCTION
12 3 45 6 7 8
DEFAULT
F-NO. FUNCTION 49 CONVERSION (OPEN RATE) CONV 2
12 3 4 56 7 8
1 (-) 50 CASH IN DRAWER ****C ID
(-)
51 CASH+CHECK IN DRAWER CA+ CH ID
2 %1 %1
52 CHECK CHANGE CHK / CG
3 %2 %2
53 VAT EXEMPT (For DOUGHNUT TAX Type1) VAT EXPT
4 NET1 NET1
54 (+) DEPT TOTAL *DEPT TL
5 TAXABLE1 ST TAX1 ST
55 (-) DEPT TOTAL DEPT ( - )
6 GROSS TAX1 GRS TAX1
56 SUBTOTAL SUBTOTAL
7 REFUND TAX1 RFD TAX1
57 MDS SBTL MDSE ST
8 NET TAX1 TAX1
58 TOTAL ***TOTAL
9 EXEMPT TAX1 TX1 EXPT
10 TAXABLE2 ST TAX2 ST 59 CHANGE CHANGE

11 GROSS TAX2 GRS TAX2 60 ITEMS ITEMS


61 DEPT. REPO. TITLE DEPT
12 REFUND TAX2 RFD TAX2
13 NET TAX2 TAX2 62 PLU REPO. TITLE PLU

14 EXEMPT TAX2 TX2 EXPT 63 TRANS. REPO. TITLE TRANS.


64 CLERK REPO. TITLE CLERK
15 TAXABLE3 ST TAX3 ST
16 GROSS TAX3 GRS TAX3 65 HOURLY REPO. TITLE HOURLY

17 REFUND TAX3 RFD TAX3 66 NON ADD CODE TEXT #


67 COPY RECEIPT TITLE COPY
18 NET TAX3 TAX3
19 EXEMPT TAX3 TX3 EXPT 68 EJ REPORT TITLE EJ

20 TAXABLE4 ST TAX4 ST 69 EJ REPORT END TITLE EJ END

21 GROSS TAX4 GRS TAX4


14) PROGRAMMING OF LOGO TEXT
22 REFUND TAX4 RFD TAX4
NO CHANGE
23 NET TAX4 TAX4
SBTL 4 X @/FOR (CHARACTERS) SBTL CA/AT
24 EXEMPT TAX4 TX4 EXPT
LINE NO.
25 GROSS M-TAX GRS MTAX
26 REFUND M-TAX RFD MTAX
27 NET M-TAX M-TAX X: LINE NO. (1 to 6)
28 NON GST SUBTOTAL GST EXPT (CHARACTERS): CHARACTER (Max. 24 Characters)
29 PST TOTAL PST TTL Characters can be entered by using the character layout on keyboard or
30 GST TOTAL GST TTL using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
31 TOTAL TAX TTL TAX
BY NUMERIC KEYS IS AS FOLLOWS:
32 NET without TAX NET
YYY3 [00] KEY
33 NET2 NET2 YYY : CHARACTER CODE (3 DIGITS)
34 REFUND REFUND (or [000] KEY ACCORDING TO PGM PRESET)
35 VOID VOID (Sample)
36 VOID MODE VO I D
37 MANAGER VOID MGR VD
38 SBTL VOID SBTL VD YOUR
39 NO SALE NO S ALE
RECE I PT
MRS =
THANK YOU
40 RA ***RA PLEASE
41 PO ***PO VI S I T
US AGA I N
42 CUSTOMER TRA NS CT
43 NET3 (SALES) NET3
44 CASH CASH
45 CHECK CHECK
46 GROSS CHARGE1 CHARGE
47 REFUND CHARGE1 CHARGE -
48 CONVERSION (PRESET RATE) CONV 1

XE-A206 PROGRAM MODE

2–6
15) PROGRAMMING OF CLERK NAME A: INTERVAL BETWEEN BREAKPOINTS A
NO CHANGE BELOW 1 DOLLAR 0
SBTL 5 XX @/FOR (CHARACTERS) SBTL CA/AT 1 DOLLAR OR MORE AND LESS THAN 100 DOLLAR 1

B: TAX TABLE No. B


TABLE1 1
XX: CLERK NO. (1 to 25) TABLE2 2
(CHARACTERS): CHARACTER (Max. 8 Characters)
TABLE3 3
Characters can be entered by using the character layout on keyboard or TABLE4 4
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER TAX RATE : 0.0001 to 99.9999
BY NUMERIC KEYS IS AS FOLLOWS:
CYCLE : 0 to 9999
YYY3 [00] KEY
INITIAL TAX : 0 to 999
YYY : CHARACTER CODE (3 DIGITS)
LOWER TAX LIMIT : 0 to 99999
( or [000] KEY ACCORDING TO PGM PRESET)
BREAK POINT : 0 to 99999
MRS = CLERKxx (xx: clerk no.)
MRS = NO TAX
16) FOREIGN CURRENCY SYMBOL PROGRAMMING
18) TAX RATE PROGRAMMING
NO CHANGE
(Inhibition programming)
SBTL 6 (CHARACTERS) SBTL CA/AT

0
(CHARACTERS): CHARACTER (Max. 4 Characters)
SBTL 9 @/FOR A @/FOR xxx.xxxx
Characters can be entered by using the character layout on keyboard or TAX NO. TAX RATE
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER 0
BY NUMERIC KEYS IS AS FOLLOWS:
@/FOR xxxxx
YYY3 [00] KEY
LOWER TAX LIMIT
YYY : CHARACTER CODE (3 DIGITS) FOR ADD TAX
(or [000] KEY ACCORDING TO PGM PRESET)
MRS = ____ ( _ : space code) SBTL CA/AT

Note: This symbol is printed as the amount of CURRENCY CONVER-


SION for PRESET RATE only. A : TAX 1 PROGRAMMING 1
The amount symbol of CURRENCY CONVERSION for OPEN
RATE is not printed. TAX 2 PROGRAMMING 2
TAX 3 PROGRAMMING 3
17) TAX TABLE PROGRAMMING TAX 4 PROGRAMMING 4
SBTL 8 @/FOR AB @/FOR xx.xxxx @/FOR % TAX RATE &SIGN
DECLARATION TAX RATE RATE xxx.xxxx = 0.0000 to 100.0000 %
OF TAX
(Table Delete programming) LOWER TAX LIMITATION 0.00 to 999.99
(This is invalid in VAT system.)
*
xxxx @/FOR xxx @/FOR MRS = DELETE
CYCLE INITIAL TAX

19) RATE HALO PROGRAMMING FOR [%] KEY


(Table Delete programming)
0

SBTL SBTL 29 @/FOR XXX.XX %n CA/AT


xxxxx @/FOR xxxxx @/FOR CA/AT
LOWER TAX LIMIT BREAK POINT

XXX.XX: % HALO (0.00 to 100.00)

72 BREAKPOINTS CAN BE PROGRAMMED FOR EACH TAXTABLE. The DECIMAL POINT must be entered for setting the decimal digits.
(Case of interval between break point is 1 dollar or more and less than MRS = 100.00 (%)
100 dollar, 36 breakpoints is programmed for each table.)
* DEPRESSION OF THE [SBTL] KEY AT THE FOLLOWING POINTS MEANS
A TAX TABLE DELETE OPERATION.

XE-A206 PROGRAM MODE

2–7
20) [AUTO] KEY PROGRAMMING [JOB#5] FUNCTION SELECT -- ABCDEFGH --
MRS = 00000001
max 25

A: PO in REG mode A
AUTO (Free key) AUTO CA/AT
ENABLE 0 ★

Delete
DISABLE 1

It must be pushed same [AUTO] key as the programming [AUTO] key at B: RA in REG mode B
the end of any key entry. ENABLE 0 ★
Note: [ESC] key cannot be set at [AUTO] key programming. DISABLE 1
It acts as a key of ERROR ESCAPE function in this programming.
C: SUBTOTAL VOID in REG mode C
< [Auto] key function > ENABLE 0 ★
This machine has [AUTO] key which can be programmed the DISABLE 1
key-sequence data.
When [AUTO] key is depressed, the machine works as same as the D: INDIRECT VOID in REG mode D
programmed key-sequence is entered. ENABLE 0 ★
DISABLE 1
Executing mode : REG, MGR, OPXZ, X1/Z1, X2/Z2
Setting mode : PGM E: DIRECT VOID in REG mode E
ENABLE 0 ★
21) DATE/TIME PROGRAMMING DISABLE 1
XXXXXXXX
DATE F: REFUND in REG mode F
#/SBTL ENABLE 0 ★

HHMM DISABLE 1
TIME
G: NO SALE in REG mode G
DATE) XXXXXXXX: YYYYMMDD or DDMMYYYY or MMDDYYYY ENABLE 0 ★
(YYYY: 2000 to 2099) DISABLE 1
(MM: 01 to 12)
H: FRACTIONAL QUANTITY H
(DD: 01 to 31)
YES (3digits decimal place) 0
The date entry format complies with the applicable PGM-mode
programming. NO 1 ★

TIME) HH: Hour (00 to 23)


[JOB#6] PRINT FORMAT -- ABCDEFGH --
MM: Minute (00 to 59)
MRS = 11000011
MRS = DATE: 01012000 (DD/MM/YYYY)
TIME: 0000 A: PRINTER FORMAT A
JOURNAL 0
22) VARIOUS PROGRAMMING RECEIPT 1 ★
(PROGRAMMING SEQUENCE) Note: Case of RECEIPT, ECR is controled the Journal Rewind Motor
0 as below.
#/SBTL AB @/FOR (NK) #/SBTL CA/AT
REG/MGR/VOID mode : Journal Rewind Motor is not driven.
PGM/OPXZ/XZ mode : Journal Rewind Motor is driven for
AB : JOB No. rewinding reports anytime.
NK : PROGRAMMING DATA. (Numeric Keys)
B: CONTENTS OF RECEIPT B
[JOB#1] MACHINE No. (6digits) -- XXXXXX -- TOTAL 0
MRS = 000000 DETAIL 1 ★

[JOB#2] CONSECUTIVE No. (4digits) -- XXXX -- C: TIME PRINTING (for all receipt) C

MRS = 0000 PRINT 0 ★


NOT PRINT 1

D: DATE PRINTING (for all receipt) D


PRINT 0 ★
NOT PRINT 1

XE-A206 PROGRAM MODE

2–8
E: CONSECUTIVE NO. PRINTING E [JOB#15] FUNCTION SELECT2 -- ABCDEFGH--
PRINT 0 MRS = 000000000

NOT PRINT 1 ★ A, B, C, D, E, F: Not used (Fixed at “000000”)

F: Not used (Fixed at “0”) G: TAX DELETE in REG mode G


ENABLE 0 ★
G: ZERO SKIP IN PLU REPORT G
DISABLE 1
NOT SKIP 0
SKIP 1 ★ H: MANUAL TAX in REG mode H
ENABLE 0 ★
H: ZERO SKIP IN GENERAL,CLERK,HOURLY H DISABLE 1
NOT SKIP 0
[JOB#19] QUANTITY FOR DOUGHNUT EXEMPT -- XX --
SKIP 1 ★
(for CANADIAN TAX)
MRS = 0

[JOB#7] RECEIPT PRINT FORMAT -- ABCDEFGH -- xx : QUANTITY FOR DOUGHNUT TAX EXEMPT = 0 to 99
MRS = 00000000
[JOB#35] ONLINE COMMUNICATION TIME OUT -- XXX --
A, B: Not used (Fixed at “00”)
MRS = 007
C: SUBTOTAL PRINT [AT] [SBTL] KEY C XXX: Time out time (1 to 255 sec)
NOT PRINT 0 ★
PRINT 1 [JOB#50] THERMAL PRINTER DENSITY CONTROL -- XX --
MRS = 50
D: MDSE SBTL PRINT AT [MDSE SBTL] KEY D
NOT PRINT 0 ★ XX: density (00 to 99)

PRINT 1 00 : 70 % for standard


50 : 100 % (Standard density)
E, F, G: Not used (Fixed at “000”) 99 : 130 % for standard

H: PURCHASE NO. PRINTING H


[JOB#61] OTHERS1 PROGRAMMING -- ABCDEFGH --
PRINT 0 ★
MRS = 00100002
NOT PRINT 1
A, B: Not used (Fixed at “00”)

[JOB#10] POWER SAVING -- YXXX -- C: Programming of MINUS dept/PLU C


Disable 0
MRS = 0030
Enable 1 ★
Y: POWER SAVING function when a time is displayed Y
Yes (Enable) 0 ★ D: Fractional treatment D

No (Disable) 1 Round off (4-DOWN, 5-UP) 0 ★


Raising to unit 1
XXX: POWER SAVING TIME to POWER OFF Disregarding 2
= 001 to 254 (minutes)
or 999 (Inhibit) E: [00] key or [000] key selection for [00] key position E
[00] key 0 ★
[000] key 1
[JOB#11] LOGO PRINTING -- A --
F: Time format F
MRS = 1
12hour 0 ★
A: LOGO MESSAGE CONTROL A 24hour 1
3-LINE HEADER INSTEAD OF GRAPHIC LOGO 0
G: Date format G
GRAPHIC LOGO ONLY 1 ★
M-D-Y 0 ★
GRAPHIC LOGO AND 3-LINE FOOTER 2
D-M-Y 1
6-LINE HEADER 3
Y-M-D 2
GRAPHIC LOGO AND 3-LINE HEADER 4
3-LINE HEADER AND 3-LINE FOOTER 5 H: TAB H
0 0
1 1
2 2 ★
3 3

XE-A206 PROGRAM MODE

2–9
[JOB#62] OTHERS2 PROGRAMMING -- ABCDEFGH -- F: Subtotal entry before tendering F
MRS = 00000000 Noncompulsory 0 ★
A: Not used (Fixed at “0”) Compulsory 1

B: ERROR BEEP for missoperation B G: Subtotal entry before direct non-tender finalization G
LOCK ERROR 0 ★ Noncompulsory 0 ★
MISSOPERATION 1 Compulsory 1

C: Key catch sound C H: Direct non-tender finalization after tendering H


Disable 0
Yes 0 ★
Enable 1 ★
No 1

D: Buffered Keyboard D [JOB#64] OTHERS4 PROGRAMMING -- ABCDEFGH --


Yes 0 ★ MRS = 00000000
No 1 A: Printing of GT1 on Z report A
Yes 0 ★
E: VOID mode E
No 1
Enable 0 ★
Disable 1 B: Printing of GT2 on Z report B
Yes 0 ★
F: Printing of VOID MODE in Z2 report F
No 1
Yes 0 ★
No 1 C: Printing of GT3 on Z report C
Yes 0 ★
G: Printing of VOID MODE in Z1 report G
No 1
Yes 0 ★
No 1 D: Printing of Training GT on Z report D
Yes 0 ★
H: Addition to the hourly total in VOID MODE H
No 1
No 0 ★
Yes 1 E: Printing of Z counter on Z report E
Yes 0 ★
No 1
[JOB#63] OTHERS3 PROGRAMMING -- ABCDEFGH --
MRS = 01000001 F: Printing of DATA on PLU resetting report F
Yes 0 ★

A: Receipting at the time of NO SALE A No 1

Yes 0 ★ G: Reset GT1,2,3 at the general Z1 report G


No 1 No 0 ★

B: NO SALE after non-add code entry B Yes 1

Disable 0 H: OP X/Z report H


Enable 1 ★ Enable 0 ★

C: NON-ADD code entry C Disable 1

Enable 0 ★
[JOB#65] OTHERS5 PROGRAMMING -- ABCDEFGH --
Disable 1
MRS = 00000000
D: Copy Receipt D
No 0 ★ A, B, C, D, E, F, G, H: Not used (Fixed at “00000000”)
Yes 1

E: Entry that causes the merchandise SUBTOTAL


E
to be smaller than zero.
Enable 0 ★
Disable 1

XE-A206 PROGRAM MODE

2 – 10
[JOB#66] OTHERS6 PROGRAMMING -- ABCDEFGH -- D: EJ print and clear at general Z1 report D
MRS = 10001100 No 0 ★
Yes 1
A: AFTER-TRANSACTION RECEIPT A
TOTAL ONLY 0 E: PGM mode programming operation records in EJ E
DETAILS 1 ★ DETAIL 0 ★
Header information only 1
B: AMOUNT PRINTING WHEN PLU UNIT PRICE IS 0 B Note: It is not effected for PGM reading and XZ reports.
No 0 ★ PGM reading and XZ reports are always treatment as
Yes 1 "HEADRER ONLY".

F: REG/MRG/VOID operation records in EJ F


C: CONVERSION SBTL PRINTING OF NATIVE SBTL C
DETAIL 0 ★
Yes 0 ★
TOTAL 1
No 1
G: Compression print for EJ report G
D: Not used (Fixed at “0”)
No (Normal size) 0
E: Compression print on journal at PGM/XZ mode E Yes (Small size) 1 ★
No (Normal size) 0
H: Action when EJ file is full H
Yes (Small size) 1 ★
Continue (No warning) 0
F: Compression print on journal at REG/MGR/ Warning (near full warining) 1 ★
F
VOID mode Lock (with near full warining) 2
No (Normal size) 0
Yes (Small size) 1 ★ [JOB#69] OTHERS9 PROGRAMMING -- ABCDEFGH --
Note: This selection is valid only when “PRINTING FORMAT” is MRS = 00000000
set as “JOURNAL”. A, B, C, D, E: Not used (Fixed at “00000”)
This selection is not valid for the printing data of EJ report.
It is provided another selection job for EJ. F: TAX PRINTING WHEN TAXABLE SUBTOTAL
F
IS ZERO
G: Logo Text Print on Journal G No 0 ★
No 0 ★ Yes 1
Yes 1
G: TAX PRINTING WHEN TAX IS ZERO G
H: FOOTER PRINT CONTROL H Yes 0 ★
ALL RECEIPTS 0 ★ No 1
ON SELECTED FUNCTION KEY AT THE TIME
1 H: Not used (Fixed at “0”)
OF FINALIZATION

[JOB#67] OTHERS7 PROGRAMMING -- ABCDEFGH -- [JOB#70] OTHERS10 PROGRAMMING -- ABCDEFGH --


MRS = 00000000 MRS = 00000000

A, B, C, D, E, F, G, H: Not used (Fixed at “00000000”) A: SPLIT PRICING COUNTING A


QUANTITY 0 ★
PACKAGE 1
[JOB#68] OTHERS8 PROGRAMMING -- ABCDEFGH --
B: MULTIPLICATION ENTRY SYSTEM B
MRS = 00100011
MULTIPLICATION ONLY 0 ★
SPLIT PRICING & MULTIPLICATION 1
A, B: Not used (Fixed at “00”)
C, D: Not used (Fixed at “00”)
C: Temporary journal printing function of transaction C
E: TAX PRINTING WHEN GST is VAT E
Disable 0
Enable 1 ★
Yes 0 ★
No 1
Note: It is a function to print one transaction data which is not
finalized (during a transaction) when a transaction is oper-
F: GST EXEMPT on X/Z F
ated at "RECEIPT OFF".
It is available only at "RECEIPT PRINTER TYPE". PRINTED 0 ★
NOT PRINTED 1

GH: TAX SYSTEM = 00 to 11


AUTO TAX = 00
CANADA TAX (GST TYPE nn) = 01 to 11

XE-A206 PROGRAM MODE

2 – 11
[JOB#71] GT2 PROGRAMMING -- XXXXXXXXXXXXX -- 24) TRAINING MODE TEXT PROGRAMMING
MRS = 0000000000000
SBTL 87 (CHARACTERS) SBTL CA/AT
XXXXXXXXXXXXX : GT (13digits)

(CHARACTERS): CHARACTER (Max. 8 characters)


[JOB#72] GT3 PROGRAMMING -- XXXXXXXXXXXXX --
Characters can be entered by using the character layout on keyboard or
MRS = 0000000000000 using numeric keys on keyboard.
XXXXXXXXXXXXX : GT (13digits) THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER
BY NUMERIC KEYS IS AS FOLLOWS:
[JOB#76] GENERAL Z1 RESET REPORT COUNTER -- XXXX -- YYY 3 [00] KEY
MRS = 0000 YYY : CHARACTER CODE (3 DIGITS)
XXXX : RESET COUNTER (4digits) (or [000] KEY ACCORDING TO PGM PRESET)
MRS = TRAINING
[JOB#77] GENERAL Z2 RESET REPORT COUNTER -- XXXX --
MRS = 0000 25) TEXT CHANGING (TO DEFAULT TEXT)
XXXX : RESET COUNTER (4digits)
0

SBTL 88 @/FOR X CA/AT


[JOB#86] TRAINING CLERK PROGRAMMING -- XX --
MRS = 0
X: 0 = English text
X : CLERK No. = 0 (INHIBIT), 1 to 25 2 = French text
3 = Spanish text
23) DOMESTIC CURRENCY SYMBOL PROGRAMMING MRS = 0
NO CHANGE When this job is executed, below texts are set as default data.
SBTL 85 (CHARACTERS) SBTL CA/AT (a) Function text
(b) Each message text (LOGO, etc..)
(CHARACTERS): CHARACTER (Max. 4 Characters)
Characters can be entered by using the character layout on keyboard or
using numeric keys on keyboard.
THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER HEADER
BY NUMERIC KEYS IS AS FOLLOWS:
YYY 3 [00] KEY 05/02/2006 12:34PM 01 DATE/TIME/CLERK NO
YYY : CHARACTER CODE (3 DIGITS) 123456#1234 BETTY___ MACHINE NO. /CC-NO. /CLERK NAME
(or [000] KEY ACCORDING TO PGM PRESET)
MRS = ___$ ( _ : space code) *PGM* MODE TITLE

This symbol is printed with (+) amount of domestic currency. #88 0 LANGUAGE MODE
The programmed characters is printed at left side of amount.

Ex) Case of " US$ ":


| DEPT.01 US$1.00 |
2
Programmed symbol
26) RESETTING OF ALL COUNTER AND TOTALIZER
If some space characters are programmed at the left side of symbol
(like “ $”), they are not counted as the number of character of the cur- SBTL 89 @/FOR CA/TL
rency symbol. (In case of “ US$”, the number of character is 3.)
All counter, totalizer, EJ data all GTs, and all Z counter are reset.
Ex) Case of “ US$”: (The currency symbol means “US$”)
|AAAADEPARTMENT01 US$10000.00 |
2
HEADER
Programmed symbol

05/02/2006 12:34PM 01 DATE/TIME/CLERK NO


123456#1234 BETTY___ MACHINE NO. /CC-NO. /CLERK NAME

*PGM* MODE TITLE

#89 JOB#

XE-A206 PROGRAM MODE

2 – 12
27) CHANGING MEMORY TYPE (*1) When [SBTL] key is pushed, ECR prints the confirmation message
(EJ RECORD AND PLU RECORD) at “RECEIPT” (not print at JOURNAL) and enforces to select either
executing or canceling this job. The buffered keys are cleared.
SBTL 90 @/FOR X CA/AT
(*2) “1” is a keyword to execute this job.

X : 0 = TYPE1 (EJ: 1000 records and PLU 2000 records) (*3) If the MODE SWITCH is turned to another mode from PGM position
1 = TYPE2 (EJ: 3000 records and PLU 200 records) or the AC POWER is off when job is executed, the job is cancelled.

MRS = 0 Note: If AC POWER is off when ECR accesses SD CRAD, the contents
in SD CARD may be broken.
When this job is executed, EJ records are deleted and PLU records are
set the default data after deleted all records even if same memory type The action of each job is as below.
is entered.
[JOB#140] Format SD CARD
This job formats SD card. (It deletes all data on SD card.)
After formatting card, the folder \SHARP\ECRXXX08 is made to a root
HEADER
directory.
And then, \ALL, \PROGRAM, \SALES, \EJPRINT, \EJ and \LOGO are
05/02/2006 12:34PM 01 DATE/TIME/CLERK NO
made to a folder “\SHARP\ECRXXX08”.
123456#1234 BETTY___ MACHINE NO. /CC-NO. /CLERK NAME The file “SRECORD.REC” is made to both folder
*PGM* MODE TITLE "\SHARP\ECRXXX08\SALES" and "\SHARP\ECRXXX08\EJ"
and it is set the default data.
#90 0 MEMORY TYPE (0: TYPE1, 1: TYPE2)
Notes: • All the data currently written in SD card is erased.
• The file “SRECORD.REC” is used for control the structure
under each folder.Any users dose not need to concern its
contents.

[JOB#141] Programming data saving to SD CARD


28) MAXIMUM NUMBER OF DEPARTMENTT
[JOB#147] Programming Data loading from SD CARD
SBTL 95 @/FOR XX CA/AT
The below data is saved or loaded.
XX : Max Number of DEPARTMENT Files are set in the folder for “Programming Data”.
This job is used for the limitation of below functions.
File/Table
(1) Programming for the department code over the maximum num- File Name Field (*1)
No. (*1)
ber of department.
1 Date and Time mtimtbl D0
(2) Registration for the department code over the maximum num-
ber of department. 2 Department deptdata 01 B000
(Label, Preset, Price, Text)
(3) Registration for the PLU that is associated to department over
3 PLU pludata 11 B000
the maximum number of department.
(Label, Preset, Price, Text)
(4) Printing for the department data over the maximum number of
4 Function FuncText A4
department at PGM READING and XZ REPORTS. programming
Mfunctbl D8
MRS = 99
5 Tax Table and mtaxtbl D7
29) SD CARD FUNCTION Rate

[Key Sequence of SD Jobs] 6 Logo message mlgxtbl D2


7 Clerk CsrData 51 All fields
(*1) (*2)
SBTL xxx @/FOR SBTL 1 CA/AT : Execute operation (*3) 8 Others mopttbl D1
Programming
CL : Cancel

(*1) The contents of each file are same as the communication data of
xxx : JOB code “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are
140 : Format SD CARD described in “ONLINE SPECIFICATION”. All data are converted to
use at “Customer Support Tool” software on PC.
141 : Save Programming Data (ECR 3 SD)
Notes: • If there is data of the same file name, the message of confir-
144 : Save All RAM Data (ECR 3 SD) mation does not display.
145 : Load Graphic Logo Data (ECR 1 SD) Data is overwritten if there is data of the same file name.
147 : Load Programming Data (ECR 1 SD) • Each files are used only for the “Customer Support Tool” soft-
ware on PC. Any users dose not need to concern its contents.
148 : Load All RAM Data (ECR 1 SD)

XE-A206 PROGRAM MODE

2 – 13
[JOB#145] Graphic logo data loading [JOB#144] All Data Saving
The below data is loaded. Files are set in the folder for “LOGO Data”. [JOB#148] All Data Loading
Notes: • In case of "DATA SAVING", the message of confirmation for
File/Table
File Name Field (*1) overwritten the file on SD Card does not display. Data is over-
No. (*1)
written if there is data of the same file name.
1 Graphic LOGO LOGO E0
• In case of "DATA LOADING", the condition of ECR will return
to past condition. However, the message of confirmation for
(*1) The contents of each file are same as the communication data of
overwritten does not display.
"ONLINE FUNCTION". Details of "File No." and "Table No." are
described in "ONLINE SPECIFICATION". All data are converted to The below data is saved or loaded. Files are set in the folder for "ALL
use at "Customer Support Tool" software on PC. RAM BACKUP".

Note: Files are created only for the "Customer Support Tool" software File Name
on PC. Any users dose not need to concern its contents. 1 All RAM data All

Note: Each files are used only for the purpose of DATA BACKUP at
ECR. Any users dose not need to concern its contents.

■ DISPLAY AND PRINT:

Key Display Print NOTE


1 2 3 4 5 6 7 8 9 0
123456789012345678901234

[STBL] P
141 P 1 4 1
[@/FOR] P 1 4 1
[SBTL] P -
(PRE-PRINT HEADDER) The buffered keys are cleared and the message is
!!!!!!!!!!!!!!!!!!!!!!!! printed on "receipt" only.
YOU SELECT SD CARD JOB (It is not print on "journal" and "EJ".)
PUSH [1]-KEY to EXECUTE
PUSH [CL]-KEY to CANCEL
!!!!!!!!!!!!!!!!!!!!!!!! MESSAGE : MAX 8-lines
Don't turn the mode key (The message is fixed in ROM.)
while executing a job.
!!!!!!!!!!!!!!!!!!!!!!!!
(Issuing Receipt) (Not count up CC# at this time.)

[1] P 1
[CA/AT] S d- AC C E S S . HEADER (Count up CC#.)
DISPLAY : "." is blinking while executing job.
05/02/2006 12:34PM 01
123456#1234 BETTY___
PRINT : JOB HEADDER is printed.
*PGM* And job code is printed.
(Job code is printed only at SD jobs)
#141

(SD ACCESS) S d- AC C E S S . DISPLAY: "." is blinking while executing job. PRINT


PRINT : (NON)
Case of NORMAL END 0. 0 0 DISPLAY: (INITIAL)
***NORMAL END
PRINT : STATUS is printed
(Issuing Receipt) (The message is fixed in ROM.)
Case of ERROR END E - S d - 0 1 DISPLAY: ERROR CODE (2-digits)
SD ERROR 01
PRINT : SD ERROR MESSAGE and ERROR
(Issuing Receipt) CODE
(The message is fixed in ROM.)
Cas e of CHANGING 0. 0 0 DISPLAY: (INITIAL)
MODE KEY SD CANCELED
PRINT : SD CANCEL MESSAGE
(to cancel) (Issuing Receipt) (The message is fixed in ROM.)
Case of POWER OFF E - S d - P. O F F DISPLAY: ERROR MESSAGE
POWER OFF ERROR
AT THE DEVICE CONTROL PRINT : MESSAGE of POWER OFF
SET DATA&TIME AGAIN
(The message is fixed in ROM.)
(Issuing Receipt)

XE-A206 PROGRAM MODE

2 – 14
4. CHARACTER ASSIGNMENT METHOD

■ PROGRAMMING KEY LAYOUT

Note:
• To distinguish from other keys, 0 - 9 , 00 , @/FOR , • and CL are represented as not square-shaped keys but round-shaped keys in this manual.
• The small characters on the bottom or lower right in each key indications or characters which can be used for character entries for text programming.

■ THE METHOD OF CHARACTER ENTRY AT TEXT PROGRAMMING


The character can be entered by using character key or character code.
When the character can be entered in the text programming, the key layout is changed from "Function and [DEPT] key layout" to "CHARACTER KEY
LAYOUT".
In "CHARACTER KEY LAYOUT", any key except the Numeric keys and [CL], [SBTL], [CA/AT] are assigned either the character or the control key for
character entry.
Any character can be entered by following mathod.
By character key:

SHIFT (CHARACTER KEY) : Characters on Character key layout.

NUMBER (NUMERIC KEY) : Numeric character ("0"), "1", . . . , "9")

By Numeric key (Character Code) :

xxx [00]

xxx : Character Code

(The list of Control Key)


Key Action
SHIFT Entry to shift the following character key. (ex. [SHIFT] 3 [A] : Enter the character "a".)
NUMBER Entry the following numeric key as the number character. (ex. [NUMBER] 3 [1] : Enter the character "1".)
(DC) Double size character: Change the following character to the double size character.
BS Back Space : Delete the last character.

The status of [SHIFT], [NUMBER] and [DC] are keeping until pushing same control key in each text entry. (STAY DOWN type)
And the corresponding indication is lighted up on the display while their status is "on".
(Example)
[SHIFT] 3 [A] [B] [C] 3 [SHIFT] 3 [A] [B] [C] : Text "abcABC".
[NUMBER] 3 [1] [2] [3] 3 [NUMBER] 3 [1] [2] [3] : Text "123" and numeric number 123.
[DC] 3 [A] [B] [C] 3 [DC] 3 [A] [B] [C] : Text "ABCABC".

XE-A206 PROGRAM MODE

2 – 15
<Character Code Table for text programming> Printer
CODE CHARACTER CODE CHARACTER CODE CHARACTER CODE CHARACTER CODE CHARACTER
001 á 049 1 098 b 147 ù 196
002 â 050 2 099 c 148 à 197
003 ê 051 3 100 d 149 Æ 198
004 î 052 4 101 e 150 φ 199
005 ì 053 5 102 f 151 Å 200

006 í 054 6 103 g 152 ¤ 201

007 ô 055 7 104 h 153 é 202

008 ó 056 8 105 i 154 è 203

009 û 057 9 106 j 155 Pt 204

010 ú 058 : 107 k 156 ¡ 205


059 ; 108 l 157 Ñ 206
011 œ
060 < 109 m 158 Õ 207
012
061 = 110 n 159 £ 208 P
013 ú
062 > 111 o 160 ¥ 209
014
063 ? 112 p 161 210
015 ó
064 @ 113 q 162 211 š
016 Λ
065 A 114 r 163 212
017 Ψ
066 B 115 s 164 213
018 Γ
067 C 116 t 165 . 214
019 .. T
068 D 117 u 166 1 215
020 Ω T
069 E 118 v 167 2 216
021 Δ T
070 F 119 w 168 3 217
022 Θ T
071 G 120 x 169 4 218
023 Ξ 1
072 H 121 y 170 2 219
024 Π 1
073 I 122 z 171 3 220
025 Σ 1
074 J 123 { 172 4 221
026 Υ 2
075 K 124 | 173 3 222
027 Φ 2
076 L 125 } 174 4 223
028 3
077 M 126 ß 175 4 224 *
029 Ú
078 N 127 176 225 §
030
079 O 128 !! 177 Á 226 Ø
031 Ó
080 P 129 1 178 227 ^
032 (Space)
081 Q 130 2 179 228 2
033 !
082 R 131 3 180 A 229 ]
034 "
083 S 132 4 181 a 230 [
035 # 084 T 133 1
/2 182 E 231
036 $ 085 U 134 F
183 e
T 232 ä
037 % 086 V 135 1 184 I 233 ö
038 & 087 W 136 3 185 i 234 ü
039 ' 088 X 137 p 186 U 235 æ
040 ( 089 Y 138 p 187 u 236 å
041 ) 090 Z 139 d 188 237 É
042 * 091 Ä 140 e 189 238 ñ
043 + 092 Ö 141 F 190
044 , 093 Ü 142 T 191 Š
045 – 094 ^ 143 4 192
046 . 095 _ 144 ç 193
047 / 096 145 O
194
048 0 097 a 146 ¿ 195 253 (DC)

Note: The character of this table is for reference.Please see actual display.
(DC) : Double Code
: ECR Control Character (Not used for text)

XE-A206 PROGRAM MODE

2 – 16
CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE
Roughly speaking, the following sales reports are available: [Purpose]
1) OP X/Z reports (Individual cashier reports) The reports are each used to check sales data. The standard purposes
of taking these reports are as follows:
2) X1/Z1 reports (Daily total X and Z reports)
OP X/Z reports : These reports are taken by operators in order to
3) X2/Z2 reports (Periodic total X and Z reports) report their own sales data.
4) Flash-read reports (Display sales amount) X1/Z1 reports : These reports are taken by the supervisor or manager in
order to check and report daily sales totals at that point.
In addition to the above reports that are to be used for program check-
X2/Z2 reports : These reports are taken by the owner or manager in
ing are also available. order to check and report periodic (weekly or monthly)
totals.
Flash-read : These reports are taken by the owner or manager in
order to check and display sales totals at that point.

[Operation]
In the table below those reports marked with a circle “o ” can be executed.
PRINTING REPORT

MODE
KEY
REPORT NAME OPX/Z X1/Z1 X2/Z2 DATA FOR READING
ENTRY
X Z X1 Z1 X2 Z2
GENERAL [CA/AT] o o o o *1, *6
PLU BY RANGE [PLU] o o PLU CODE *1, *2
CRERK (ALL) [CLK]# o o *1
CRERK (INDIVIDUAL) [CLK]# o o *1, *3
HOURLY (ALL) [#/SBTL] o o *1

FLASH READING REPORT


MODE
REPORT NAME KEY ENTRY OPX/Z X1/Z1 X2/Z2 DATA FOR READING
X Z X1 Z1 X2 Z2
DEPARTMENT [DPTn] *4
or [SHIFT] 3 [DPTn] o
or NK 3 [DEPT#] DEPT CODE
CID [@/FOR] o *4
PAID TOTAL [CA/AT] o *4

OTHERS OPERATION
MODE
REPORT NAME JOB# OPX/Z X1/Z1 X2/Z2 DATA FOR READING
X Z X1 Z1 X2 Z2
EJ report (ALL) 700 o o o o *5, *6
EJ report (Latest 10 records) 710 o o *5, *6

MODE: X : Daily operater X report Z : Daily operater Z report


X1 : Daily X report Z1 : Daily Z report
X2 : Periodic X report Z2 : Periodic Z report
(X report): The corresponding data is held in the ECR.
(Z report): The corresponding data is cleared in the ECR.

XE-A206 OP X/Z, X1/Z1, X2/Z2 MODE

3–1
• Stop of printing reports (Report cancel function): [Action]
This ECR has the function of report stopping for PLU report and EJ
Individual counters for the following Z reports are incremented when
report.
those reports are printed.
• Printing of GT on X reports:
1) General daily total report (Z1)
This ECR dose not print any GT on X reports.
2) General periodic total report (Z2)
[Additional function]
*1 To read respective reports, it is necessary to follow the procedure
(1) Overflow mark
below.
If the amount or quantity in any totalizer other than GT to be printed
Reading on X or Z reports exceeds a programmed limit, the indication mark
(X report) (overflow mark) is printed for the totalizer concerned.
KEY The overflow mark may be printed even if a totalizer does not reach
the maximum amount. This occurs, for example, when the amount
Resetting
(Z report) or quantity in the totalizer gets smaller than the maximum amount
due to the entry of a negative amount after the overflowing of the
*2 PLU code range can be specified by entering the start and end totalizer. This means that when the totalizer overflows once, the
numbers according to the following procedure. overflow mark (for example, “!!”) is printed.
When specifying a single PLU code, the start number has only to be (2) MODE TITLE
entered. Each report is printed MODE TITLE at a header of report.
All The Report Titles are as follows.
Reading OPX report *OPX*
XXXX @/FOR XXXX PLU OPZ report *OPZ*
Start No. End No.
Resetting X1 report *X 1*

*3 To read respective reports, it is necessary to follow the procedure Z1 report *Z 1*


below. The clerk code does not need to enter at the OPX/Z mode. X2 report *X 2*
In OPX/Z mode, it is issued the report of the assigned clerk.
Z2 report *Z 2*
*4 Reading display only.
The displayed amount can be cleared by [CL] key. (3) Report cancel function
It can be cancelled by turned the mode switch to MGR position
KEY CL
while the data is printed. (In this case, the contents of memory are
(Display amount) (Display initialize)
not cleared.)
*5 To read respective contents, it is necessary to follow the procedure below. <Print sample of Report cancel>

Reading :
:
JOB# @/FOR CA/AT * * * * * 1 the report cancel symbol
Resetting
123456789012345678901234

*6 It is able to print and clear the EJ memory at general Z1 report by


PGM mode programming.
In that case, the contents of EJ memory is printed just after issued
general Z1 report.
(Issuing general Z1 report 3 Clear daily DEPT & TRANS memory 3
Issuing EJ memory 3 Clear EJ memory)

XE-A206 OP X/Z, X1/Z1, X2/Z2 MODE

3–2
ELECTRONIC JOURNAL REPORT
This job is own to print and clear EJ memory in X1/Z1 mode and OPXZ mode. [JOB#650] Sales data saving
[Key sequence] All sales data (Daily and term) save in SD card.
This job is used for the purpose of using Electric Journal Data at the
1) Reading and resetting of all records:
“Customer Support Tool” software on PC. Maximum 400 times data is
[OPXZ, X1/Z1 mode]
kept in SD Card when the SD memory is not full.
(Reading)
The action is as below.
700 @/FOR CA/AT
Step1) After reading the information of the current sub-folder in
(Reseting)
“SRECORD.REC” file, ECR creates the new sub-folder under
2) Reading of the latest 10 records: the folder for “Sales Data”.
[OPXZ, X1/Z1 mode] Its folder is named ASCII Character that is indicated the number
of sales data in SD Card. (Example: “1”, “2”, “3”,......)
710 @/FOR CA/AT
Step2) Save the below data in new sub-folder that is created above step.

[ACTION] File/Table
File Name Field (*1)
No. (*1)
It prints all or parts of printing data in EJ memory.
1 Date and Time mtimtbl D0
The printing format is same as each operation.
(When a job is operated)
It is able to print and clear the EJ memory at general Z1 report by PGM 2 Department Sales Dept 01 All fields
mode programming.
3 Transaction Sales Trans 21 All fields
In that case, the contents of EJ memory is printed just after issued gen-
eral Z1 report. Func Text A4
(Issuing general Z1 report 3 Clear daily DEPT & TRANS memory 3 4 Hourly Sales Hourly 61 All fields
Issuing EJ memory 3 Clear EJ memory)
5 Clerk Sales Csr Data 51 All fields

[Report cancel function] Csr Sal 52 All fields


6 PLU Sales Plu 11 All fields,
It can be cancelled by turned the mode switch to MGR position while EJ
All range1
data is printed. (In this case, the contents of EJ memory are not cleared.)
[Key Sequence of SD Jobs] Spet 3) Create the “STATUS.REC” file in new sub-folder
when all files are saved completely.
(*1) (*2)
xxx @/FOR SBTL 1 CA/AT : Execute operation (*3)
File Name
yyy CL : Cancel
1 Status information STATUS.
REC
xxx: JOB code
Step 4) Update the “SRECORD.REC” file for changing the structure of
650: Save Sales Data (ECR 3 SD)
sub-folder.
750: Save and Clear EJ Data (ECR 3 SD)
yyy: JOB code File Name

740: Printing EJ Data on SD (ECR 1 SD) 1 Record structure SRECORD.


REC
(*1) When [SBTL]-key is pushed, ECR prints the confirmation
(*1) The contents of each file are same as the communication data of
message at “RECEIPT” (not print at JOURNAL) and enforces to
“ONLINE FUNCTION”. Details of “File No.” and “Table No.” are
select either executing or canceling this job. The buffered keys are
described in “ONLINE SPECIFICATION”. All data are converted to
cleared.
use at “Customer Support Tool” software on PC.
(*2) “1” is a keyword to execute this job.
Note: Each files are used only for the “Customer Support Tool” soft-
(*3) If the MODE SWITCH is turned to another mode from X1Z1 ware on PC. Any users dose not need to concern its contents.
position or the AC POWER is off when job is executed, the job is
cancelled. [JOB#750] Electric Journal Saving and Clearing on memory
750 @/FOR CA/AT
Note: If AC POWER is off when ECR accesses SD CRAD, the contents
in SD CARD may be broken. Electric journal data is saved in SD card.
The action of each job is as below. This job is used for the purpose of using Electric Journal Data at the
“Customer Support Tool” software on PC. Maximum 400 times data is
kept in SD Card when the SD memory is not full.
Note: After saving EJ data, ECR is clear the Electronic Journal memory.

XE-A206 OP X/Z, X1/Z1, X2/Z2 MODE

3–3
The action is as below. Step6) Clear EJ DATA on memory at ECR.
Step1) Save the below data in the folder for “Electric Journal for printing”. (*1) The contents of each file are same as the communication data of
File/Table “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are
File Name Field (*1)
No. (*1) described in “ONLINE SPECIFICATION”. All data are converted to
1 EJ Data EJFILE A0 use at “Customer Support Tool” software on PC.
Notes: • The file in the EJPRINT folder on SD Card is overwritten.
Step2) After reading the information of the current sub-folder in The message of confirmation for overwritten the file in the
“SRECORD.REC” file, ECR creates the new sub-folder under
EJPRINT folder on SD Card does not display.
the folder for “Electric Journal Data”.
Its folder is named ASCII Character that is indicated the number • Each files are used only for the “Customer Support Tool” soft-
of sales data in SD Card. (Example: “1”, “2”, “3”,......) ware on PC. Any users dose not need to concern its contents.

Step3) Save the below data in new sub-folder that is created above step.
[JOB#740] Electric journal print
File/Table
File Name Field (*1)
No. (*1) ECR prints the below data that is already set in the folder for “EJPRINT Data”.
1 EJ Data EJFILE A0
File/Table
File Name Field (*1)
No. (*1)
Spet4) Create the “STATUS.REC” file in new sub-folder when all files
1 EJ Data EJFILE A0
are saved completely.
File Name
(*1) The contents of each file are same as the communication data of
1 Status information STATUS. “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are
REC
described in “ONLINE SPECIFICATION”. All data are converted to
use at “Customer Support Tool” software on PC.
Step5) Update the “SRECORD.REC” file for changing the structure of
sub-folder. Notes: • It is printed only the newest EJ DATA (That is saved at last by
either ECR or PC).
File Name
1 Record structure SRECORD • Each files are used only for the “Customer Support Tool” soft-
.REC ware on PC.Any users dose not need to concern its contents.

■ DISPLAY AND PRINT: X1/Z1 MODE)


JOB ENTRY OPERATION: (Common action for all Jobs)

Key Display Print NOTE


1 2 3 4 5 6 7 8 9 0
123456789012345678901234

750 [ . ] 7 5 0.
[@/FOR] 7 5 0.
[SBTL] - The buffered keys are cleared and the message is
(PRE-PRINT HEADDER) printed on “receipt” only.
!!!!!!!!!!!!!!!!!!!!!!!!
(It is not print on “journal” and “EJ”.)
YOU SELECT SD CARD JOB
PUSH [1]-KEY to EXECUTE
PUSH [CL]-KEY to CANCEL
!!!!!!!!!!!!!!!!!!!!!!!! MESSAGE: MAX 8-lines
Don't turn the mode key
(The message is fixed in ROM.)
while executing a job.
!!!!!!!!!!!!!!!!!!!!!!!!
(Issuing Receipt) (Not count up CC# at this time.)
[1] 1
[CA/AT] S d - AC C E S S . (Count up CC#.)
HEADER
DISPLAY: “ . ” is blinking
while executing job.
05/02/2006 12:34PM 01
PRINT : JOB HEADDER is printed.
123456#1234 BETTY___ And job code is printed.
(Job code is printed only at SD jobs)
*Z1*
Case of EJ PRINT:
#750 The EJ DATA is printed as same as EJ
REPORT (#700) after printing job code.
(SD ACCESS) S d - AC C E S S . DISPLAY : “ . ” is blinking
while executing job.
PRINT : (NON)
:
:

--- Continue to JOB END MESSAGE (NEXT PAGE)

XE-A206 OP X/Z, X1/Z1, X2/Z2 MODE

3–4
[JOB END MESSAGE] Case of DATA SAVING (“SALES” or “EJ DATA”):

Key Display Print NOTE


1 2 3 4 5 6 7 8 9 0
123456789012345678901234

NORMAL END 0. 0 0 DISPLAY: (INITIAL)


***NORMAL END PRINT : STATUS is printed
(Issuing Receipt) (The message is fixed in ROM.)

ERROR END E - S d - 0 1 DISPLAY: ERROR CODE (2-digits)


SD ERROR 01 PRINT : SD ERROR MESSAGE and ERROR CODE
(Issuing Receipt) (The message is fixed in ROM.)

CANCEL 0. 0 0 DISPLAY: (INITIAL)


(CHANGING MODE SD CANCELED PRINT : SD CANCEL MESSAGE
KEY) (Issuing Receipt) (The message is fixed in ROM.)

POWER OFF E - S d - P. O F F DISPLAY: ERROR MESSAGE


POWER OFF ERROR
AT THE DEVICE CONTROL PRINT : MESSAGE of POWER OFF
SET DATA&TIME AGAIN (The message is fixed in ROM.)
(Issuing Receipt)

The messages are printed on both RECIPT and JOURNAL and recorded in EJ memory.

[JOB END MESSAGE] Case of EJ DATA PRINTING:

Key Display Print NOTE


1 2 3 4 5 6 7 8 9 0
123456789012345678901234

NORMAL END 0. 0 0 DISPLAY: (INITIAL)


(Issuing Receipt)
PRINT : (NON)
ERROR END E - S d - 0 1 DISPLAY : ERROR CODE (2-digits)
* * * * * * PRINT : The report cancel symbol, SD ERROR
SD ERROR 01 MESSAGE and ERROR CODE
(Issuing Receipt) (The message is fixed in ROM.)

CANCEL 0. 0 0 DISPLAY: (INITIAL)


(CHANGING MODE * * * * * * PRINT : The report cancel symbol and SD CAN
KEY) SD CANCEL CEL MESSAGE
(Issuing Receipt) (The message is fixed in ROM.)

POWER OFF E - S d - P. O F F DISPLAY: ERROR MESSAGE


* * * * * * PRINT : The report cancel symbol, POWER OFF
POWER OFF ERROR ERROR MESSAGE and Notes message
AT THE DEVICE CONTROL
SET DATA&TIME AGAIN (The message is fixed in ROM.)

(Issuing Receipt)

The report cancel symbol is printed on both RECIPT and JOURNAL, but it is not recorded in EJ memory.
The messages except the report cancel symbol are printed on both RECIPT and JOURNAL and recorded in EJ memory.

[ERROR CODE LIST]


No. Description
01 SD card is not find
02 SD CARD PROTECT SWITCH is set “PROTECED”
03 SD CARD WRITTING ERROR (Memory is full) (ECR cannot write the data on SD card.)
04 SD CARD READING ERROR (File is nothing)
05 SD CARD READING ERROR (File data is failed) (ECR cannot read the data on SD card.)
: <<< Reserved >>>
10 Over limitation of data records (Over max record in sales or EJ data.)
: <<< Reserved >>>
99 SD CARD ERROR (Anyhow error except above SD ERROR is occurred when ECR
accesses SD Card.)

XE-A206 OP X/Z, X1/Z1, X2/Z2 MODE

3–5
COPYRIGHT  2009 BY SHARP CORPORATION
All rights reserved.
Printed in Japan.
No part of this publication may be reproduced,
stored in a retrieval system, or transmitted,
in any form or by any means,
electronic; mechanical; photocopying; recording or otherwise
without prior written permission of the publisher.

Trademark acknowledgements
Microsoft ® Windows ® operating system is a trademark or copyright of Microsoft
Corporation in the U. S.A. and other countries.
Windows® 95, Windows® 98, Windows ® Me, Windows NT ® 4.0, Windows ® 2000,
Windows ® XP, Windows ® Vista, Windows ® 2000 Server, Windows ® Server 2003
and Internet Explorer® are trademarks or copyrights of Microsoft Corporation in the
U.S.A. and other countries.
IBM and PC/AT are trademarks of International Business Machines Corporation.
Acrobat ® Reader Copyright ® 1987 -2002 Adobe Systems Incorporated. All rights
reserved. Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks
of Adobe Systems Incorporated.
All other trademarks and copyrights are the property of their respective owners.

SHARP CORPORATION
Business Solutions Group
CS Promotion Center
Yamatokoriyama, Nara 639-1186, Japan
2009 October Printed in Japan