CTRDK

The document outlines the parameters and settings for a PLC system, including timer limits, run-pause contacts, and error checks. It details configurations for various components such as I/O assignments, built-in Ethernet port settings, and device assignments. The document is structured to provide a comprehensive overview of the PLC's operational settings as of January 3, 2025.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
17 views37 pages

CTRDK

The document outlines the parameters and settings for a PLC system, including timer limits, run-pause contacts, and error checks. It details configurations for various components such as I/O assignments, built-in Ethernet port settings, and device assignments. The document is structured to provide a comprehensive overview of the PLC's operational settings as of January 3, 2025.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 37

ctrdk

Comment

Prepared By

Date
PLC Parameter 1/3/2025
Data Name : PLC System
PLC System
[Timer Limit Setting]
Low Speed 100 ms
High-Speed 10.00 ms

[RUN-PAUSE Contacts]
RUN X
PAUSE X

[Latch Data Backup Function]


Device Name - -
-

[Remote Reset]
Not allowed

[Output Mode at STOP to RUN]


Previous State

[Floating Point Arithmetic Processing]


-

[Common Pointer No. ]


P After

[Points Occupied by Empty Slot]


16 Points

[System Interrupt Settings]


Interrupt Counter Start No. -
I28 Fixed Scan Interval 100.0 ms
I29 Fixed Scan Interval 40.0 ms
I30 Fixed Scan Interval 20.0 ms
I31 Fixed Scan Interval 10.0 ms

[Interrupt Program / Fixed Scan Program Setting]


High-Speed Execution is not valid

[Module Synchronization]
Synchronize intelligent module's pulse up

[A-PLC Compatibility Setting]


Use of special relay / special register from SM/SD 1000 is not valid

[Service Processing Setting]


Execute the process as the scan time proceed 10 %

[PLC Module Change Setting]


No setting

[Built-in CC-Link Setting]


-

1
PLC Parameter 1/3/2025
Data Name : PLC File
PLC File
[File Register]
Not Used

[Comment File Used in a Command]


Not Used

[Device Initial Value]


Not Used

[File for Local Device]


Not Used

[File used for SP.DEVST/S.DEVLD Instruction


Not Used

2
PLC Parameter 1/3/2025
Data Name : PLC RAS
PLC RAS
[WDT(Watchdog Timer)Setting]
WDT Setting 200 ms
Initial Execution Monitoring Time ms
Low Speed Execution Monitoring Time - ms

[Error Check]
Battery Check Valid
Fuse Blown Check Valid
I/O Module Verify Valid
Check Device Range at Indexing Valid
Diagnose Redundant Power Supply System Valid
[Operating Mode When There is an Error]
Computation Error Stop
Expanded Command Error Stop
Fuse Blown Stop
Module Verify Error Stop
Intelligent Module Program Execution Error Stop
File Access Error Stop
Memory Card Operation Error Stop
External Power Supply OFF Stop

[Constant Scanning]
ms

[Error history]
-
Target Memory -
File Name -
History No. - Item

[Low Speed Program Execution Time]


- ms

[Module Error History Collection (Intelligent Function Module


Collection of intelligent function module error histories is val
Target Memory System Memory
History No. - Item
Collection No. 1 Items/Scan

3
PLC Parameter 1/3/2025
Data Name : Boot File
Boot File
[Boot Option]
Clear Program Memory is not valid.
High-Speed Monitor Area from Other Station- K Steps
Online Change Area of Multiple Blocks - K Steps

4
PLC Parameter 1/3/2025
Data Name : Program
Program
[Program]
File Usability Setting
Program Execute Fixed Scan
In Unit Device Initial
Name Type Interval File Register Comment Local Device
Value
MAIN Scan Use PLC File Use PLC File Use PLC File Use PLC File
1 Setting Setting Setting Setting

5
PLC Parameter 1/3/2025
Data Name : SFC
SFC
[SFC Program Start Mode]
Initial Start

[Start Conditions]
Autostart Block 0

[Output Mode When the Block is Stopped]


Turn OFF

6
PLC Parameter 1/3/2025
Data Name : Device
Device
[Device]
Device Latch (1) Latch (1) Latch (2) Latch (2) Local Device Local Device Write Protection Write Protection
Sym. Dig.
Points Start End Start End Start End Start End
Input Relay X 16 8K
Output Relay Y 16 8K
Internal Relay M 10 8K
Latch Relay L 10 8K
Link Relay B 16 8K
Annunciator F 10 2K
Link Special SB 16 2K
Edge Relay V 10 2K
Step Relay S 10 8K
Timer T 10 2K
Retentive Timer ST 10 0K
Counter C 10 1K
Data Register D 10 12K
Link Register W 16 8K
Link Special SW 16 2K
Index Z 10 20

Device Total 28.8 K Words


Word Device 25.0 K Words
Bit Device 44.0 K Bits

7
PLC Parameter 1/3/2025
Data Name : Device
Device
[File Register Extended Setting]

Capacity K Points

Device Latch (1) Latch (1) Latch (2) Latch (2) Device No. Device No. Write Protection Write Protection
Sym. Dig.
Points Start End Start End Start End Start End
File Register ZR(R) 10 0K
Extended Data D 10 0K
Extended Link W 16 0K

8
PLC Parameter 1/3/2025
Data Name : Device
Device
[Indexing Setting for ZR Device]
32Bit Indexing Z After

[Latch Interval Setting]


-

[Pointer Extended Setting for Automatic-Assign Device


-

9
PLC Parameter 1/3/2025
Data Name : I/O Assignment
I/O Assignment
[Base Setting]
Base Model Name Power Model Name Extension Cable Slots
Main 8
Ext.Base1
Ext.Base2
Ext.Base3
Ext.Base4
Ext.Base5
Ext.Base6
Ext.Base7

10
PLC Parameter 1/3/2025
Data Name : I/O Assignment
I/O Assignment
[I/O Assignment]

Main
PLC 0 1 2 3 4 5 6 7
PLC Input Output Intelligent
Power
Supply
- 16Points 16Points 32Points

Start XY - 0000 0010 0020


Error Time - - Clear Clear - - - - -
Output
Mode
PLC - - - Stop - - - - -
Operation
Mode at
H/W Error
I/O - 10ms - - - - - - -
Response
Time
Control PLC - - - - - - - - -
1 - - - - - - - -
Switch Setting

2 - - - - - - - -
3 - - - - - - - -
4 - - - - - - - -
5 - - - - - - - -

11
PLC Parameter 1/3/2025
Data Name : Built-in Ethernet Port Setting
Built-in Ethernet Port Setting
IP Address 192.168.3.39 ( C0.A8.03.27 )
Subnet Mask Pattern - (-)
Default Router IP Address - (-)
Communication Data CodeBinary Code
Enable not Online Change
Enable direct connection to MELSOFT
Do respond to search for CPU (Built-in Ethernet port) on network

IP packet transfer setting Not to use IP packet relay function

12
PLC Parameter 1/3/2025
Data Name : Built-in Ethernet Port Setting
Built-in Ethernet Port Setting
[Built-in Ethernet Port Open Setting]
Host Station Destination Destination Start Device to Store
Protocol Open System TCP Connection
Port No. IP Address Port No. Predefined Protocol Operation Status
1 UDP MELSOFT Connection
2 TCP MELSOFT Connection
3 TCP MELSOFT Connection
4 TCP MELSOFT Connection
5 TCP MELSOFT Connection
6 TCP MELSOFT Connection
7 TCP MELSOFT Connection
8 TCP MELSOFT Connection
9 TCP MELSOFT Connection
10 TCP MELSOFT Connection
11 TCP MELSOFT Connection
12 TCP MELSOFT Connection
13 TCP MELSOFT Connection
14 TCP MELSOFT Connection
15 TCP MELSOFT Connection
16 TCP MELSOFT Connection

13
PLC Parameter 1/3/2025
Data Name : Built-in Ethernet Port Setting
Built-in Ethernet Port Setting
[Built-in Ethernet Port FTP Parameter Setting]
FTP Not Used
Login Name QNUDECPU
Password Setting
Command Input Monitoring Timer 1800 X 500ms

14
PLC Parameter 1/3/2025
Data Name : Built-in Ethernet Port Setting
Built-in Ethernet Port Setting
[Built-in Ethernet Port Time Setting]
SNTP Function Setting Not Used
SNTP Server IP Address- (-)
Time Zone (GMT+9:00)
Execute not time setting at turn ON/reset
On-error ActionContinue
Execution Time 12:00

15
PLC Parameter 1/3/2025
Data Name : Acknowledge XY Assignment
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(0- 0) Input 16 Points
0010 I/O Assignment 1(0- 1) Output 16 Points
0020 I/O Assignment 2(0- 2) Intelligent 32 Points
0030 I/O Assignment 2(0- 2) Intelligent 32 Points
0040 I/O Assignment 3(0- 3) Empty 16 Points
0050 I/O Assignment 4(0- 4) Empty 16 Points
0060 I/O Assignment 5(0- 5) Empty 16 Points
0070 I/O Assignment 6(0- 6) Empty 16 Points
0080 I/O Assignment 7(0- 7) Empty 16 Points

16
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Valid Module During Other Station Access1
Interlink Transmission Parameters No setting
Routing Parameters No setting

17
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 1 Module 2 Module 3 Module 4
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total (Linked) Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

18
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 5 Module 6 Module 7 Module 8
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total (Linked) Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

19
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module 9 Module10 Module11 Module12
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total (Linked) Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

20
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Ethernet/CC IE/MELSECNET
[Ethernet/CC IE/MELSECNET]
Module13 Module14 Module15 Module16
Network Type None None None None
Start I/O No. - - - -
Network No. - - - -
Total (Linked) Stations - - - -
Group No. - - - -
Station No. - - - -
Mode - - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -

21
Network Parameter 1/3/2025
Data Name : Ethernet/CC IE/MELSECNET
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(0- 0) Input 16 Points
0010 I/O Assignment 1(0- 1) Output 16 Points
0020 I/O Assignment 2(0- 2) Intelligent 32 Points
0030 I/O Assignment 2(0- 2) Intelligent 32 Points
0040 I/O Assignment 3(0- 3) Empty 16 Points
0050 I/O Assignment 4(0- 4) Empty 16 Points
0060 I/O Assignment 5(0- 5) Empty 16 Points
0070 I/O Assignment 6(0- 6) Empty 16 Points
0080 I/O Assignment 7(0- 7) Empty 16 Points

22
Network Parameter 1/3/2025
Data Name : CC-Link
CC-Link Setting
[CC-Link Setting]

Number of Modules Boards

23
Network Parameter 1/3/2025
Data Name : CC-Link
CC-Link Setting
[CC-Link Setting]
1 2 3 4
Start I/O No. - - - -
Type - - - -
Master Station Data Link Type - - - -
Mode - - - -
Total Module Connected - - - -
Remote input(RX) - - - -
Remote output(RY) - - - -
Remote register(RWr) - - - -
Remote register(RWw) - - - -
Ver.2 Remote input(RX) - - - -
Ver.2 Remote output(RY) - - - -
Ver.2 Remote register(RWr) - - - -
Ver.2 Remote register(RWw) - - - -
Special relay(SB) - - - -
Special register(SW) - - - -
Retry Count - - - -
Automatic Reconnection Station Count - - - -
Standby Master Station No. - - - -
PLC Down Select - - - -
Scan Mode Setting - - - -
Delay Time Setting - - - -
Remote Device Station Initial Setting - - - -
Interrupt Settings - - - -

24
Network Parameter 1/3/2025
Data Name : CC-Link
Acknowledge XY Assignment
[Acknowledge XY Assignment]
Type
XY No. Slot Module Type Points Model Name Duplication
Network I/O Assignment
0000 I/O Assignment 0(0- 0) Input 16 Points
0010 I/O Assignment 1(0- 1) Output 16 Points
0020 I/O Assignment 2(0- 2) Intelligent 32 Points
0030 I/O Assignment 2(0- 2) Intelligent 32 Points
0040 I/O Assignment 3(0- 3) Empty 16 Points
0050 I/O Assignment 4(0- 4) Empty 16 Points
0060 I/O Assignment 5(0- 5) Empty 16 Points
0070 I/O Assignment 6(0- 6) Empty 16 Points
0080 I/O Assignment 7(0- 7) Empty 16 Points

25
Program setting 1/3/2025
Data Name : Program setting

Execution type Program file name Local


[Title] device comment
Initial Program - -

Scan Program MAIN None

Standby Program - -

Fixed Scan Program - -

No Execution Type - -

26
Ladder 1/3/2025
Data Name : MAIN

X0 X1 X3 Y20
0 Y20 A/S 8 12 27 225
START STOP EMER STO PLC READ A/S
P Y

Y20

PLC READ
Y

Y20
12 Y21
PLC READ ALL AXIS
Y SERVO O
N

SM400 Y20 U2\ U2\G12


14 DMOV K1000 G12 B/D 28
PLC READ B/D
Y

U2\ U2\G14
DMOV K1000 G14 B/D 33
B/D

M2 U2\ U2\G1502
38 MOV K1 G1502 B/D 46
RESET ER B/D
R

X1 X3
50 Y24
STOP EMER STO AXIS1 ST
P OP

M3
60 Y28
JOG + HM FORWARD
I RUN JOG

U2\ U2\G1519
DMOV K2000 G1519 B/D 68 75 181
B/D

M4
73 Y29
JOG - HM REVERSE
I RUN JOG

U2\ U2\G1519
DMOV K2000 G1519 B/D 68 75 181
B/D

27
Ladder 1/3/2025
Data Name : MAIN

X4 U2\ U2\G1500
80 MOV K9001 G1500 A/S 92 107
SET HOME B/D 88 103 199

U2\ M22
= G1500 K9001 M22 A/S 121
TO SET H A/S
OME

X2 U2\ U2\G1500
97 MOV K9002 G1500 A/S 92 107
RESET B/D 88 103 199

U2\ M6
= G1500 K9002 M6 A/S 120
TO GO HO A/S
ME

M6 X2C Y12 Y13 X3


112 Y30
TO GO HO AXIS1 BU XLCĐ CA XLCĐ CA EMER STO POSITION
ME SY T1 T2 P START

M22

TO SET H
OME

M901

T3 M23

T3 D200
131 D+ K1000000 D200 D100 A/S 132 154 189 210 231
CURRENT B/D 137 250 275 313
FEED VAL D200
UE A/S 290
B/D
D100
A/S 145 206 214 235 271
B/D 132 281
D100
A/S 317
B/D

28
Ladder 1/3/2025
Data Name : MAIN

SM400 U2\ U2\G800


136 DMOV G800 D200 A/S 137 206
current CURRENT A/S
feed val FEED VAL D200
ue UE A/S 132 154 189 210 231
B/D 137 250 275 313
D200
A/S 290
B/D
U2\ U2\G802
DMOV G802 D300 A/S 141
MACHINE A/S
FEED VAL D300
UE B/D 141
B/D

U2\ D100
DMOV D100 G2006 A/S 145 206 214 235 271
ADDRESS B/D 132 281
POSITION D100
A/S 317
B/D
U2\G2006
B/D 145
B/D
U2\ U2\G2004
DMOV K600000 G2004 B/D 149
COMMAND B/D
SPEED

X7 M18
154 D= D200 K0 M18 A/S 161
CURRENT CB CO PH ĐK ĐẦ A/S
FEED VAL OI U
UE

X0 M18 M20 X2 Y11


160 Y11 A/S 162 169
START ĐK ĐẦ ĐÃ VỀ RESET XLCĐ PH A/S
U GỐC OI

Y11

XLCĐ PH
OI

Y11 M9 X1 X3 K20 T1
169 T1 A/S 177
XLCĐ PH DỪNG CẮ STOP EMER STO A/S
OI T P

T1 X6
177 Y28
CB VTRI FORWARD
TÍNH CH RUN JOG
IỀU DÀ
I CẮT

M3 U2\ U2\G1519
DMOV K20000 G1519 B/D 68 75 181
JOG + HM B/D
I

29
Ladder 1/3/2025
Data Name : MAIN

T3 M23 U2\ U2\G2000


186 DMOV H100 G2000 B/D 194
B/D

M102 U2\ U2\G1500


D> D200 K0 MOV K1 G1500 A/S 92 107
CURRENT B/D 88 103 199
FEED VAL
UE

M901
PLS M901 A/S 122
B/D 203

SM400 U2\ D100


205 D= G800 D100 D< D200 K6000000 D+ D100 K1000000 D100 A/S 145 206 214 235 271
current CURRENT B/D 132 281
feed val FEED VAL D100
ue UE A/S 317
B/D
D100
A/S 145 206 214 235 271
B/D 132 281
D100
A/S 317
B/D
X2C X2C Y20 X1 M23 X3 M103
219 M103 A/S 220 230 248
AXIS1 BU AXIS1 BU PLC READ STOP EMER STO A/S
SY SY Y P

M103

M103 X6 X1 Y14 X3 K50 T0


230 D< D200 K6000000 T0 A/S 284 321
CURRENT CB VTRI STOP XLNH LƯ EMER STO B/D 249
FEED VAL TÍNH CH ỠI CƯA P
UE IỀU DÀ
I CẮT

D= D100 K0

M103 T0 M23 X2 M9 Y12


248 D>= D200 K0 Y12 A/S 299 306
CURRENT RESET DỪNG CẮ XLCĐ CA B/D 127 285
FEED VAL T T1
UE

Y13
Y13 A/S 300 307
XLCĐ CA B/D 128 286
T2

T3 X1 X3 K15 T2
259 T2 A/S 266
STOP EMER STO A/S
P

T2 X1 X3 M23
266 M23 A/S 227 254
STOP EMER STO B/D 124 187
P

30
Ladder 1/3/2025
Data Name : MAIN

SM400 X2C D100


270 D> D100 K6000000 DMOV K0 D100 A/S 145 206 214 235 271
AXIS1 BU B/D 132 281
SY D100
A/S 317
B/D

D>= D200 K6000000


CURRENT
FEED VAL
UE

T0 Y12 Y13 X1 X3 M102


284 M102 A/S 188
XLCĐ CA XLCĐ CA STOP EMER STO A/S
T1 T2 P

M20
290 D= D200 K0 M20 A/S 163
CURRENT ĐÃ VỀ A/S
FEED VAL GỐC
UE

Y12 Y13 M9 X1 X3 Y10


295 Y10 A/S 301 308
XLCĐ CA XLCĐ CA DỪNG CẮ STOP EMER STO MAY CAT A/S
T1 T2 T P

Y10

MAY CAT

Y12 Y13 Y10 X5 X2 Y14


306 Y14 A/S 309
XLCĐ CA XLCĐ CA MAY CAT CB CẮT RESET XLNH LƯ B/D 242
T1 T2 ĐỨT ỠI CƯA

Y14

XLNH LƯ
ỠI CƯA

T0 M9
313 D<> D200 K0 D= D100 K0 M9 B/D 170 256 302
CURRENT DỪNG CẮ B/D
FEED VAL T
UE

X6 K10 T3
323 T3 A/S 123 131 186 259
CB VTRI A/S
TÍNH CH
IỀU DÀ
I CẮT

328 END

31
Device Comment 1/3/2025
Data Name : COMMENT
Device Name Comment
M0 START HMI
M1 STOP HMI
M2 RESET ERR
M3 JOG + HMI
M4 JOG - HMI
M5 GO HOME HMI
M6 TO GO HOME
M7 SET HOME HMI
M8 BĐ TÍNH CHIỀU DÀI CẮT
M9 DỪNG CẮT
M10 CÓ PHÔI 1
M11 CÓ PHÔI 2
M12 SET LENGTH HMI
M13 CBXL CĐ PHÔI
M14 CBXL CĐ TRÊN 1
M15 CBXL CĐ TRÊN 2
M16 CBXL CĐ NGANG 1
M17 CBXL CĐ NGANG 2
M18 ĐK ĐẦU
M19 CĐ PHÔI
M20 ĐÃ VỀ GỐC
M21 CB XL Đ
M22 TO SET HOME
M900 GO 1
X0 START
X1 STOP
X2 RESET
X3 EMER STOP
X4 SET HOME
X5 CB CẮT ĐỨT
X6 CB VTRI TÍNH CHIỀU DÀI CẮT
X7 CB CO PHOI
X2C AXIS1 BUSY
X20C AXIS1 BUSY
Y10 MAY CAT
Y11 XLCĐ PHOI
Y12 XLCĐ CAT 1
Y13 XLCĐ CAT 2
Y14 XLNH LƯỠI CƯA
Y20 PLC READY
Y21 ALL AXIS SERVO ON
Y24 AXIS1 STOP
Y28 FORWARD RUN JOG
Y29 REVERSE RUN JOG
Y30 POSITION START
D200 CURRENT FEED VALUE
D400 LENGTH SET
U2\G800 current feed value
U2\G802 MACHINE FEED VALUE
U2\G2004 COMMAND SPEED
U2\G2006 ADDRESS POSITION

32
TC Setting 1/3/2025
Data Name : MAIN
Position Device Setting Value
( 173) T1 K20
( 244) T0 K50
( 262) T2 K15
( 324) T3 K10

33
Device List 1/3/2025
Data Name : Device List

Find In:(Entire project)


Find What:Used Device (Contact & Coil)
Print Range:Whole Range

*:in use, (counts): the number of coil uses

Device Contact Coil (counts) Parameter Comment


M6 * *( 1) TO GO HOME
M9 * *( 1) DỪNG CẮT
M18 * *( 1) ĐK ĐẦU
M20 * *( 1) ĐÃ VỀ GỐC
M22 * *( 1) TO SET HOME
M23 * *( 1)
M102 * *( 1)
M103 * *( 1)
M901 * *( 1)
Y10 * *( 1) MAY CAT
Y11 * *( 1) XLCĐ PHOI
Y12 * *( 1) XLCĐ CAT 1
Y13 * *( 1) XLCĐ CAT 2
Y14 * *( 1) XLNH LƯỠI CƯA
Y20 * *( 1) PLC READY
D100 * *( 3)
D101 * *( 3)
D200 * *( 1) CURRENT FEED VALUE
D201 * *( 1)
T0 * *( 1)
T1 * *( 1)
T2 * *( 1)
T3 * *( 1)
U2 * *( 12)

34
Statement/Note 1/3/2025
Data Name : MAIN
[Line Statement List]

Step Line Statement


0 PLC READY
14 CÀI TG TANG GI?M T?C
38 RESET ERR
50 DUNG TRUC
60 CHAY JOG
80 SET HOME
97 VE GOC
112 CHAY VI TRI
295 CAT

35
Project Contents List 1/3/2025
Data Name : Project Contents List
Workspace Name :
Project Name : thunghiem2
Title :

Data Name Last Change Title


Parameter 02/12/2024 13:56:19
PLC Parameter 02/12/2024 13:56:19
Network Parameter 02/12/2024 13:56:19
Ethernet / CC IE / MELSECNET 02/12/2024 13:56:19
CC-Link 02/12/2024 13:56:19
Remote Password 02/12/2024 13:56:19
Intelligent Function Module 03/01/2025 17:51:56
0020:QD75MH4 03/01/2025 17:51:56
Parameter
Servo_Parameter
Positioning_Axis_#1_Data
Positioning_Axis_#2_Data
Positioning_Axis_#3_Data
Positioning_Axis_#4_Data
Starting_Axis_#1_Block_Data
Starting_Axis_#2_Block_Data
Starting_Axis_#3_Block_Data
Starting_Axis_#4_Block_Data
Auto_Refresh
Global Device Comment 02/01/2025 09:32:29
Program Setting
Initial Program
Scan Program
MAIN 02/12/2024 13:56:19
MAIN 03/01/2025 18:03:23
Standby Program
Fixed Scan Program
No Execution Type
POU
Program 02/12/2024 13:56:19
MAIN 03/01/2025 18:03:23
Local Device Comment
Device Memory 02/12/2024 13:56:19
MAIN 02/12/2024 13:56:19
Device Initial Value 02/12/2024 13:56:19

36

You might also like