0% found this document useful (0 votes)
30 views31 pages

KZ Factor Calculation (AutoRecovered)

The document provides detailed calculations of Kz factors for various columns and beams in a structural framework, including lengths, individual member lengths, and effective length factors. It includes specific Kz values derived from charts and calculations for multiple columns (C1 to C5) and beams (B1 to B5), along with their respective properties. The document also references ACI 318 standards for sway frames and presents ratios for K factor calculations at different joints.

Uploaded by

rohit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views31 pages

KZ Factor Calculation (AutoRecovered)

The document provides detailed calculations of Kz factors for various columns and beams in a structural framework, including lengths, individual member lengths, and effective length factors. It includes specific Kz values derived from charts and calculations for multiple columns (C1 to C5) and beams (B1 to B5), along with their respective properties. The document also references ACI 318 standards for sway frames and presents ratios for K factor calculations at different joints.

Uploaded by

rohit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 31

Middle Column, Kz factpr

Fot to Plinth Kz = 1.6

Column GF to FF - Middle Column

Length = 4.1 m
SKY & SKZ = 1.6

End Column Kz Factor


1 Fotting top to PL , Kz = 1.85

Effective Length factor to calculate MMF - GF to FF

Overall Length = 4.1 m

Individual member length = 0.5

Kz = 3.25

SKZ = 26.65
Crane supporting Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.75

SKZ = 33.6

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

D
B5

960 cm
C3

C
B3 G B4

C2 C5
410 cm

F
B
B1 B2
C1 C4
230 cm
E
A 537.5 cm

712.5 cm 537.5 cm
I of COL L of COL I/L, Col
COLUMN B(Cm) D (cm) (cm^4) (cm)
C1 60 75 2109375 230 9171
C2 60 75 2109375 410 5145
C3 60 75 2109375 960 2197
C4 60 60 1080000 230 4696
C5 60 60 1080000 410 2634

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 40 50 416667 712.5 585
B2 40 50 416667 537.5 775
B3 50 60 900000 712.5 1263
B4 50 60 900000 537.5 1674
B5 50 80 2133333 1250 1707

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 14316 585 24.5

Kz From Chart = 1.85

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 14316 585 24.48
Ⴤ@C= 7342 1263 5.8

Kz From Chart = 3.25


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C= 7342 1263 5.81
Ⴤ@D= 2197 1707 1.29

Kz From Chart = 1.75

K Factor calculation for C4

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@E= - - 0 For fixed condition Phi A =0
Ⴤ@F= 7330 1360 5.4

Kz From Chart = 1.6

K Factor calculation for C5

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@F= 7330 1360 5.39
Ⴤ@G= 2634 2938 0.9

Kz From Chart = 1.6


Middle Column, Kz factpr
Fot to Plinth Kz = 1.6

Column GF to FF - Middle Column

Length = 4.1 m
SKY & SKZ = 1.6

End Column Kz Factor


1 Fotting top to PL , Kz = 1.85

Effective Length factor to calculate MMF - GF to FF

Overall Length = 4.1 m

Individual member length = 0.5

Kz = 3.25

SKZ = 26.65
Crane supporting Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.75

SKZ = 33.6

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

D
B5

960 cm
C3

C
B3 G B4

C2 C5
410 cm

F
B
B1 B2
C1 C4
230 cm
E
A 537.5 cm

712.5 cm 537.5 cm
I of COL L of COL I/L, Col
COLUMN B(Cm) D (cm) (cm^4) (cm)
C1 60 75 2109375 230 9171
C2 60 75 2109375 410 5145
C3 60 75 2109375 960 2197
C4 60 60 1080000 230 4696
C5 60 60 1080000 410 2634

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 40 50 416667 712.5 585
B2 40 50 416667 537.5 775
B3 50 60 900000 712.5 1263
B4 50 60 900000 537.5 1674
B5 50 80 2133333 1250 1707

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 14316 585 24.5

Kz From Chart = 1.85

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 14316 585 24.48
Ⴤ@C= 7342 1263 5.8

Kz From Chart = 3.25


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C= 7342 1263 5.81
Ⴤ@D= 2197 1707 1.29

Kz From Chart = 1.75

K Factor calculation for C4

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@E= - - 0 For fixed condition Phi A =0
Ⴤ@F= 7330 1360 5.4

Kz From Chart = 1.6

K Factor calculation for C5

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@F= 7330 1360 5.39
Ⴤ@G= 2634 2938 0.9

Kz From Chart = 1.6


Middle Column, Kz factpr
Fot to FF Kz = 1.08

Effective Length factor to calculate MMF - FDN to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.38

SKZ = 17.664
Crane supporting Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.42

SKZ = 27.264

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

C B3

960 cm
C2

B
B1 E B2

640 cm
C1
C3

D
A 537.5 cm

712.5 cm 537.5 cm
L of COL I/L, Col
COLUMN B(Cm) D (cm) I of COL (cm^4) (cm)
C1 60 75 2109375 640 3296
C2 60 75 2109375 960 2197
C3 60 60 1080000 640 1688

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 45 70 1286250 712.5 1805
B2 45 70 1286250 537.5 2393
B3 60 100 5000000 712.5 7018

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 5493 1805 3.0

Kz From Chart = 1.38

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 5493 1805 3.04
Ⴤ@C= 2197 7018 0.3

Kz From Chart = 1.42


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C=- - 0.00
Ⴤ@D= 1688 4198 0.40

Kz From Chart = 1.08


Middle Column, Kz factpr
Fot to FF Kz = 1.08

Effective Length factor to calculate MMF - FDN to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 0.95

SKZ = 12.16
Crane supporting Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.45

SKZ = 27.84

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

C B3

510 cm
C2

B
B1 E B2

640 cm
C1
C3

D
A 537.5 cm

712.5 cm 537.5 cm
L of COL I/L, Col
COLUMN B(Cm) D (cm) I of COL (cm^4) (cm)
C1 60 60 1080000 640 1688
C2 60 60 1080000 510 2118
C3 60 60 1080000 640 1688

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 45 70 1286250 712.5 1805
B2 45 70 1286250 537.5 2393
B3 45 70 1286250 712.5 1805

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 3805 1805 2.1

Kz From Chart = 0.95

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 3805 1805 2.11
Ⴤ@C= 2118 1805 1.2

Kz From Chart = 1.45


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C=- - 0.00
Ⴤ@D= 1688 4198 0.40

Kz From Chart = 1.08


Effective Length factor to calculate MMF - GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.38

SKZ = 17.664
Crane supporting Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.58

SKZ = 30.336

Mid column Column- GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.12

SKZ = 14.336

Mid column Column- FF to RF

Overall Length = 9.6 m

Individual member length = 0.5

Kz = 1.3

SKZ = 24.96

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

C
B3 F B4
C2 C4 960 cm

B
B1 E B2

C1
C3 640 cm

D
A 537.5 cm

712.5 cm 537.5 cm
I of COL L of COL I/L, Col
COLUMN B(Cm) D (cm) (cm^4) (cm)
C1 60 75 2109375 640 3296
C2 60 75 2109375 960 2197
C3 60 60 1080000 640 1688
C4 60 60 1080000 960 1125

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 45 70 1286250 712.5 1805
B2 45 70 1286250 537.5 2393
B3 45 70 1286250 712.5 1805
B4 45 70 1286250 537.5 2393

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 5493 1805 3.0

Kz From Chart = 1.38

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 5493 1805 3.04
Ⴤ@C= 2197 1805 1.2

Kz From Chart = 1.58


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C= 0 0 0.00
Ⴤ@D= 2813 4198 0.67

Kz From Chart = 1.12

K Factor calculation for C4

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ @ E = 2813 4198 0.67 For fixed condition Phi A =0
Ⴤ@F= 1125 4198 0.27

Kz From Chart = 1.3


Effective Length factor to calculate MMF - GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.28

SKZ = 16.384
Crane supporting Column- FF to RF

Overall Length = 5.1 m

Individual member length = 0.5

Kz = 1.48

SKZ = 15.096

Mid column Column- GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.3

SKZ = 16.64

Mid column Column- FF to RF

Overall Length = 5.1 m

Individual member length = 0.5

Kz = 1.2

SKZ = 12.24

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

C
B3 F B4
C2 C4 510 cm

B
B1 E B2

C1
C3 640 cm

D
A 537.5 cm

712.5 cm 537.5 cm
I of COL L of COL I/L, Col
COLUMN B(Cm) D (cm) (cm^4) (cm)
C1 60 60 1080000 640 1688
C2 60 60 1080000 510 2118
C3 60 60 1080000 640 1688
C4 60 60 1080000 510 2118

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 45 70 1286250 712.5 1805
B2 45 70 1286250 537.5 2393
B3 45 70 1286250 712.5 1805
B4 45 70 1286250 537.5 2393

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ@B= 3805 1805 2.1

Kz From Chart = 1.28

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 3805 1805 2.11
Ⴤ@C= 2118 1805 1.2

Kz From Chart = 1.48


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C= 0 0 0.00
Ⴤ@D= 3805 4198 0.91

Kz From Chart = 1.3

K Factor calculation for C4

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ @ E = 3805 4198 0.91 For fixed condition Phi A =0
Ⴤ@F= 2118 4198 0.50

Kz From Chart = 1.2


Effective Length factor to calculate MMF - GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.45

SKZ = 18.56
Mid Column- FF to FF1

Overall Length = 5.1 m

Individual member length = 0.5

Kz = 2.1

SKZ = 21.42

Mid column Column- FF1 to RF

Overall Length = 4.5 m

Individual member length = 0.5

Kz = 1.3

SKZ = 11.7

Effective Length factor to calculate MMF - GF to FF

Overall Length = 6.4 m

Individual member length = 0.5

Kz = 1.05

SKZ = 13.44

Mid Column- FF to FF1

Overall Length = 5.1 m

Individual member length = 0.5

Kz = 1.3

SKZ = 13.26
Mid column Column- FF1 to RF

Overall Length = 4.5 m

Individual member length = 0.5

Kz = 1.22

SKZ = 10.98

K factor for Column for SWAY FRAMES - Fig R 6.2.5 of ACI 318 (M) -2014
1250 cm

D B5 H B6

C3 450 cm
C6

C B3 G B4

510 cm
C2 C5

B
B1 F B2

C1
C4 640 cm

E
A 537.5 cm

712.5 cm 537.5 cm
I of COL L of COL I/L, Col
COLUMN B(Cm) D (cm) (cm^4) (cm)
C1 60 75 2109375 640 3296
C2 60 75 2109375 510 4136
C3 60 75 2109375 450 4688
C4 60 60 1080000 640 1688
C5 60 60 1080000 510 2118
C6 60 60 1080000 450 2400

I/L, Beam
I of BEAM L of BEAM
BEAMS B(Cm) D (cm) (cm^4) (cm)
B1 45 70 1286250 712.5 1805
B2 45 70 1286250 537.5 2393
B3 45 70 1286250 712.5 1805
B4 45 70 1286250 537.5 2393
B5 45 70 1286250 712.5 1805
B6 45 70 1286250 537.5 2393

K Factor calculation for C1

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@A= 0 0 0 For fixed condition Phi A =0
Ⴤ @ B = 7432 1805 4.1

Kz From Chart = 1.45

K Factor calculation for C2

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@B= 7432 1805 4.12
Ⴤ@C= 8824 1805 4.9

Kz From Chart = 2.1


K Factor calculation for C3

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@C= 8824 1805 0.00
Ⴤ@D= 4688 1805 2.60

Kz From Chart = 1.3

K Factor calculation for C4

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ@E= 0 0 0.00 For fixed condition Phi A =0
Ⴤ@F= 1688 4198 0.40

Kz From Chart = 1.05

K Factor calculation for C5

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ @ F = 3805 4198 0.91 For fixed condition Phi A =0
Ⴤ @ G = 4198 4198 1.00

Kz From Chart = 1.3

K Factor calculation for C6

Ⴤ@A= Ratio, sum of ( I/L ) of Col meeting at Joint / sum of (I/L) of Beams meeting at Joint

Sum (I/L) Sum (I/L)


Col Beam Ratio Remark
Ⴤ @ G = 4518 4198 1.08
For fixed condition Phi A =0
Ⴤ @ H = 2400 4198 0.57

Kz From Chart = 1.22