E) SETTINGS
Press the M button and then switch on the scale. The scale has the following
user settings in this menu:
1. DUMMY ZERO: The user can enable or disable the DUMMY ZERO display
with this setting. Select YES or NO depending on whether you want to display
the dummy zero or not.
2. AUTO ZERO: After dummy zero selection the display will show“A-0 X”.
Here the user can select the range of the autozero. “A-0 0” means auto
zero function disabled and the display will show even the first count from the
OWNERS MANUAL
zero level. “A-0 3” means the auto zero range is 3d, meaning that the scale
Cruzer
will auto zero any reading between 0d and 3d at the zero level, to maintain
the correct zero on the scale.
F) CALIBRATION
External Calibration Setting
Press the ZERO Button and switch on the scale. The display will show “PASS”
and then “000000”. Press the ZERO Button. The display will show “CAL”. Press
the ZERO the display will briefly show “no Load” and then the internal division at
no load condition. Make sure for the decimal point to stop blinking, and then SHIPPING SCALES
press the ZERO Button. The display will show “LOAD” briefly and then again the
internal counts. Keep the calibration weight and press the ZERO Button, the
display will show “000000”. Now enter the value of the calibration weight kept
using the UP and LEFT Arrow Keys. Finally press the ZERO Button, the display
will show the calibrated weight. If the difference between this external
calibration and the previous internal calibration is more than 5%, the new
calibration will not be stored and the scale will pick up the values / setting
according to the old internal calibration only. If the user feels that the new
external calibration is correct and still the scale is not accepting it, then the
correct way to do the calibration will be to do the internal calibration again.
G) BATTERIES
The scale is capable of running on rechargeable battery or 6 pcs of AA size
batteries, if the scale is not connected to the mains through the adaptor for any
reason. The following is recommended to maximize the life of the batteries
• If the scale is not used for long, it is highly recommend to remove the
batteries from the scale, as there are chances that batteries may leak and
damage the scale beyond repair.
• Please charge the battery for at least 20 hours before using for first time.
• The battery automatically gets charging once the scale adaptor is plugged in to
the mains; hence only make sure that the GREEN LED on the top right side of the
display is ON.
G) MAINTENANCE
# The user should never put weight more than the designed capacity of the scale
# When the scale is switched on, whenever the user will put more load than the
designed capacity of scale, then display will show “-OL-” meaning that the scale is
overloaded. Even if the scale is no in use and is switched off, if load above the
designed capacity of the scale is applied on the weighing pan, by keeping some
weight, or by hand, or any other means, the scale can be damaged beyond repairs.
# Never clean the scale with highly intensive solvents like petrol, thinner or acetone
etc. the best way to clean the scale is to use a slightly moist cloth, and then use a dry
cloth to wipe again.
Version 2.01
4 1
Owner’s Manual Shipping Scales Cruzer Series Cruzer Series Shipping Scales Owner’s Manual
A) TECHNICAL DETAILS stable, the decimal point stops blinking and the user can be sure that the
weight being shown is the correct weight.
o Hold function: In the weighing mode if you press the hold button after
Measurement Data Weighing Scales keeping the weight, the displayed weight will start blinking this means that
Capacity 20kg - 75kg
the hold function is active. Once the display stops blinking the hold mode is
Tare range subtractive 100% subtractive
Repeatability 1d +-
turned off.
Display Resolution 6000 ~ 10,000 divisions
Application Modes Weighing, Counting D) FUNCTIONS
Product Features Pre-Set Tare, Glow Control, Set HI, LO a) HOLD Function: The scale has a hold function which can be used to hold the
Keyboard 4 membrane keys (Hol d, Mode, Counting, and Zero) weight display. In weighing mode, keep a weight and wait for the decimal point to
Weighing Units Kg stop blinking. Once the decimal point is stable, now user can press the HOLD
Calibration Digital with external weight. button. The display will start blinking, and the weight will be hold on the display
Weight 1.8kg approx without any movement if you add some weight or remove some weight. Also if
Front Display Type 0.56” Bright red LED display you remove the total weight, the previous weight will still be displayed at which
Stabilization 2 seconds the hold button was pressed. Now to come out of the hold mode, simply press
9V Adaptor / built in battery for backup to the hold button again, or keep a new weight. The scale will automatically
Power
25hrs. / 6 x AA dry battery understand a new weight has been kept, and it will exit the HOLD mode, and
Operating Temp. 50° to 98° F / 10° to 35° C display the new weight correctly.
B) SETTING UP THE SCALE: b) SET POINT Function: The function is mainly used for packing or check weighing
Take the scale out of the box and place on a stable surface. Place the Top pan function. The user can pre define the level at which he needs the alarm to sound.
correctly on the scale. Insert the DC pin of the adaptor, and connect the adaptor When the display is showing “0.00”, press the M button, the display will show
to the nearest mains point and / or install 6 pcs of AA batteries by removing the “SET LO”, now press the zero button, the display will show “000000” or the
battery cover. previous entered value. Enter a value using the Up arrow and the left shift arrow
For best performance, do not place the scale on a surface where: and then press the Zero Button. Now the display will show “SET HI” and the user
The surface has effect of Vibrations can similarly enter the HI value. The following logic is followed in this mode:
The air movement is more, like directly under a fan, or in open in windy condition o SET LO value is entered only: If the user only enters the SET LO value and
ON / OFF Switch: The on/off switch is located on the rear side of the scales. The keep the SET HI value as “0.00”, the scale will sound the beep sound below
switch has 3 positions. At the centre position the scale is turned off and can be the SET LO value.
pushed left or right to run the scale on rechargeable battery or dry batteries. o SET HI value is entered only: If the user only enters the SET HI value and
Note : The scale has 3 power inputs a) Rechargeable battery, Dry Battery and keep the SET LO value as “0.00”, the scale will sound the beep sound above
power adaptor. the SET HI value.
o SET LO & SET HI both are entered: If the user enter both SET LO and SET HI
value, the beep will not sound below between the SET Lo and SET HI value
C) OPERATION range, and the beep will sound below the LO value and above the HI value.
a) Buttons Please note the following points:
o ZERO: This button is used to zero an unwanted reading on the display. This o The beep sound will sound only when the stable light stops blinking, that is the
button is also used for going in to the calibration mode. weight is stable.
o HOLD: This button is used for holding the weight on the display. o The BUZZER is not provided as standard, and it needs to be installed by the
o M / UP Arrow: This button is used for Setting the LO and High Limit in the dealer / reseller. Without the buzzer installed, the beep sound cannot be
heard.
scale. The button is also used as the up arrow key in the setting menu.
o Counting / Left Shift Key: This button is used for counting function. This c) Counting Function: The scale has counting mode which can be used for parts
button is also used as the left shift key in the setting menu. counting. In the weighing mode, keep a weight on the scale. When the decimal point
stops blinking, press the Counting Button. The display will show the value according
b) Indications: There are three visual indications in the scale which are as follows: to the previously entered data. Now press the M button, the Display will show
o Power LED: When you connect the adaptor to the scale, the GREEN LED on “SM0010” which is selection mode for the number of pcs. Press the M button again
the bottom right side of the display will glow. When the LED will glow, you display will show “SM0020”, so that the user can select the appropriate number as
can be sure the scale is being powered from the main supply, and that the per the number of samples kept on the scale in the beginning. After correct selection
battery is being charged. press the ZERO Button, the display will show the pieces counting. To go back to the
o Stable weight indication: In the weighing or the counting mode, when you weighing mode, press the Counting Button again. You will come back to the weighing
keep the weight you will notice that the decimal point is blinking. The blinking mode and the display will show the weight. Press the counting button again and
decimal point means that the weight is not stable. Once the weight is again, to toggle between the counting mode and weighing mode.
2 3