The RG302529: Enhanced BCCH Energy Saving feature enhances the BSS20958:
Energy saving mode for BCCH TRX with additional dB transmit power reduction modes.
What is more, the RG302529 feature reduces electricity consumption even more in
cooperation with the BSS20958 feature.
The greatest energy savings are provided by the dummy burst power reduction during
periods of low traffic, for example at night time. With the dynamic power control of active
dedicated channels, the feature reduces electricity consumption throughout the day.
Impact on interfaces
The RG302529: Enhanced BCCH Energy Saving feature impacts interfaces as follows:
• Abis telecom
– Extended controlling functions of UTPFIL parameters.
Requirements
Alarms
There are no new alarms related to the RG302529: Enhanced BCCH Energy Saving
feature.
Commands
There are no new commands related to the RG302529: Enhanced BCCH Energy Saving
feature.
Parameters
Sales information
Procedure
1 Modify the feature state of Enhanced BCCH Energy Saving from OFF to ON.
Step example
ZW7M:FEA= 29016:ON;
2 Activate Enhance BCCH Energy saving feature at BSC for the sector.
Step example
ZEUG:BTS=<BTS_ID>:TPR=<0-8>;
g Note: The values of TPR, currently, are 0 to 8. The value 0 indicates Energy saving
mode is off, and value 2-8 indicates that Energy saving feature is active with power
reduction of step of 2dB.
Procedure
1 Modify the feature state of Enhanced BCCH Energy Saving from ON to OFF.
Step example
ZW7M:FEA= 29016:OFF;
7.1.7.1 Purpose
The purpose of this test case is to verify Enhanced BCCH Energy Saving feature.
Upto 8 db (also 4 and 6 db) Reduction in BCCH TRX Power Level (So far only 2db
reduction allowed as part of BSS 20958).
Extending power reduction to TSL 7 (Presently applied only on 1-6).
• Windows OS Laptop
7.1.7.3 Preconditions:
7.1.7.4 Steps
1 Check that the licence covering Energy Saving Mode for BCCH TRX has been installed
(W7I).
ZW7I:LIC,FULL:LIC=<licence code>;
2 Check the value of the BCCH power saving feature and enhanced Energy Saving Mode
for BCCH TRX feature state (W7I).
ZW7I:FEA,FULL:FEA=1237;
ZW7I:FEA,FULL:FEA=29016;
ZW7M:FEA=1237:ON;
ZW7M:FEA=29016:ON;
ZW7I:FEA,FULL:FEA=1237;
ZW7I:FEA,FULL:FEA=29016;
5 Activate Energy Saving Mode for BCCH TRX for the desired segment (EUG).Set the
BCCH TRX TX pwr reduction (TPR) parameter value to 2 ~8 dB in the desired segment.
ZEUG:SEG=<SEG identification>:TPR=<*>;
6 Set enhance BCCH power saving related parameter for the desired segment(EUG).
at time
defined by
Enhanced
BCCH
energy
saving start
time hour
and
Enhanced
BCCH
energy
saving start
time minute.
ZEEI;
=== ===
Configure parameter TPR to 2,4,6 or 8, setup CS call after parameter changing, and
then check counters.
ZEUG:BTS=11:TPR=2,;
LOADING PROGRAM VERSION 29.5-0
EXECUTION STARTED
mcBSC MBSC19 2016-08-24 10:08:46
POWER CONTROL GENERAL PARAMETERS OF
SEG-0011 BD33
BTS-0011 BD33
POWER CTRL ENABLED ......... Y POWER CONTROL INTERVAL ..... 02 s
BS TX PWR MIN ....PEAK PWR - 30 dB BS TX PWR MAX ....PEAK PWR - 00 dB
BS TX PWR MAX1X00 PEAK PWR - 00 dB
POWER INCR STEP SIZE ....... 0 dB POWER RED STEP SIZE ........ 2 dB
POWER DECR LIMIT BAND 0 .... 38 dB POWER DECR LIMIT BAND 1 .... 38 dB
POWER DECR LIMIT BAND 2 .... 38 dB POWER DECR QUAL FACTOR ..... 1
ALA ENABLED ................ N MIN INT BETWEEN ALA ........ 10 s
POWER LIMIT ALA ............ 6 dB BCCH TRX TX PWR REDUCTION .. 2 dB
< ZERO:BTS=11,TRX=1;
TRANSCEIVER DATA
ADM.STATE OP.STATE
--------------------------------------
BCF-0001 UNLOCKED WO
SEG-0011 BD33
BTS-0011 BD33 UNLOCKED WO
TRX-001 EDGE UNLOCKED WO
BCXU-1
RFHA Y
COMMAND EXECUTED
Object number 0 :
Type :
113
Check word (hex) :
6666
Object :
BTS ID (LSB) : 0bh
BTS ID (MSB) : 00h
BTS ID (dec) : 11d
not relevant : 00h
not relevant : 00h
Object 2 : ff ff ff ff
113010 : 4DB_REDUCED_BCCH_PWR_ON_SDCCH :
0000000000
113011 : 6DB_REDUCED_BCCH_PWR_ON_SDCCH :
0000000000
113012 : 8DB_REDUCED_BCCH_PWR_ON_SDCCH :
0000000000
113013 : 4DB_REDUC_BCCH_PWR_ON_TCH_FR :
0000000003
113014 : 6DB_REDUC_BCCH_PWR_ON_TCH_FR :
0000000001
113015 : 8DB_REDUC_BCCH_PWR_ON_TCH_FR :
0000000111
113016 : 4DB_REDUC_BCCH_PWR_ON_TCH_HR :
0000000000
113017 : 6DB_REDUC_BCCH_PWR_ON_TCH_HR :
0000000000
113018 : 8DB_REDUC_BCCH_PWR_ON_TCH_HR :
0000000000
7.3.2 Abstract
RG602507 – Automatic output power adjustment for Multi-Carrier configurations for
GF17 provides the following benefits:
7.3.3 Prerequisites
Following Network Elements/ Equipments are required:
• One 2G-LTE RF sharing, RF unit HW Rel 3.0 (FXED, FXEE, FXEF, FHEL) or later.
• One LTE carrier and four GSM carrier configuration.
• One BSC