0% found this document useful (0 votes)
15 views9 pages

Documentation: Air Units - Eco-Line - Type Eir ..., Eiw ..., Eif ..., Eil ..., Eic ...

The document provides detailed documentation for Eco-Line air units, including operation manuals, technical data, and safety instructions. It covers installation, operation, and maintenance of various components such as pressure regulators, filter regulators, and lubricators. Additionally, it includes specifications and dimensions for different models, ensuring proper usage and maintenance of the equipment.

Uploaded by

wilkoooo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
15 views9 pages

Documentation: Air Units - Eco-Line - Type Eir ..., Eiw ..., Eif ..., Eil ..., Eic ...

The document provides detailed documentation for Eco-Line air units, including operation manuals, technical data, and safety instructions. It covers installation, operation, and maintenance of various components such as pressure regulators, filter regulators, and lubricators. Additionally, it includes specifications and dimensions for different models, ensuring proper usage and maintenance of the equipment.

Uploaded by

wilkoooo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

200417

Documentation

Air units - Eco-Line


- Type EiR ... , EiW ... , EiF ... , EiL ... , EiC ... -
Stand: 10/2020
Documentation Air units - Eco-Line

1. Content
2. Operation manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3. Articlenumbers and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.1 Pressure regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Filter regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.5 Lubricators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.6 Air units, 2-piece . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4. Spare Parts and equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2. Operation manual

1. SAFETY INSTRUCTIONS

• Warning! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

• Warning! Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.

• Keep the equipment clean and maintain it in good condition (use an authorized service agent).

• Replace or repair damaged parts. Use genuine parts only. Unauthorized parts may be dangerous and will invalidate the warranty.

• Warning! Ensure that the correct air pressure is maintained and not exceeded.

• Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections are secure.

• DO NOT direct air from the air hose at yourself, others or animals.

• Drain the compressor air tank daily. Water in the air line will damage your equipment.

• When work is complete ensure that the air supply is turned off.

2. INSTALLATION

Confirm that all items are present and undamaged.

Air Supply

Outlet to the
Air Product

Filter Oiler
Regulator

The drawing shows a typical air line installation. The filter is located upstream of the regulator - unless combined- and the lubricator downstream.

Filter/regulator - Install using the mounting bracket provided. Before connecting system piping ensures that gauge is visible, unused gauge port is sealed with plug
provided and that flow direction arrow matches system air flow.

Filter and Lubricator - Install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that flow arrows are correct and
that filter is upstream, and lubricator downstream, of regulator.

Note: To ensure air-tight joints, use PTFE tape.

3. OPERATION

Pressure regulators
The output pressure is controlled by the knob. Before pressurizing the air system for the first time, pull out and rotate the knob anticlockwise to remove any loading on
the regulator spring. Pressurize the system and then rotate knob clockwise to set required output pressure, as shown on gauge. When the required pressure is achie-
ved push in knob to prevent inadvertent adjustment.
For correct pressure setting always adjust up from a lower pressure. Therefore to reset from 90 to 70 psi for example, reduce pressure from 90 to 60 psi and then in-
crease to 70 psi.

Filter
The bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of the bowl, allow to drain and then re-
lease. Semi-automatic drainage and automatic drainage with float: As soon as the inlet pressure falls below the minimum input pressure, the drain valve opens.

Lubricator
Remove the filler plug and fill bowl up to max. level, with air tool oil. This can be done with the air line pressurised. With air flowing through the lubricator the oil deli-
very rate can be adjusted by screw whilst watching the drip rate through the sight dome. The oil delivery rate will automatically increase or decrease in line with the
air flow.

Metal bowl guard


Both the filter and the lubricator are supplied with a metal bowl guard. To remove the guard, pull down the latch and rotate the guard until either of the two pairs of
lines on the guard align with the similar marks on the head. The guard can now be removed. To refit, slide the top of the guard into the head with the guard and
head markings aligned, and then rotate the guard so that the latch aligns with the marks on the head. The latch will lock into place.

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 2


Documentation Air units - Eco-Line

3. Articlenumbers and technical data

Pressure regulators Eco-Line e!


good valu
Version: Resettable (with relieving system) Especially
Materials: Body: Aluminium, spring hood: Polyamide, diaphragm and seals: NBR
Temperature range: Up to max. +60°C L
Input pressure: 1.5 - 10 bar (Pressure regulation range: 0.5 - 8.5 bar), media: Compressed air

ü Advantages: • Automatic venting in the event of overpressure on the secondary side


• Easy assembly of individual components from a particular model series using coupling kits
• Hand wheel can be locked by pressing down on it

H2
• Mounting brackets included in the scope of delivery
• Space saving compact pressure gauge already assembled

H1
Flow Panel
Type Thread l/min L H1 H2 thread Model series
EiR 2000-02 G 1/4“ 1200 40 93 76 M 33 x 1.5 2
EiR 3000-03 G 3/8“ 2200 53 128 93 M 42 x 1.5 3
EiR 4000-04 G 1/2“ 5300 70 150 112 M 52 x 1.5 4
EiR 5000-10 G 1“ 6600 90 168 120 M 52 x 1.5 5

Main dimensions - Pressure regulators Eco-Line

H
C
D

G I
F
H1

E
A

Thread
L B

Type Thread L H1 A B C D E F G H I
EiR 2000-02 G 1/4“ 40 93 17 55 31 34 44 5,4 15,0 55 2
EiR 3000-03 G 3/8“ 53 128 35 64 39 40 46 6,5 8,0 53 2
EiR 4000-04 G 1/2“ 70 150 38 81 48 54 55 8,5 10,5 70 2
EiR 5000-10 G 1“ 90 168 49 84 48 54 63 8,5 10,5 70 2

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 3


Documentation Air units - Eco-Line

Filter regulators Eco-Line


e!
Version: Resettable pressure regulator (with relieving system) and additional filtering using the centrifugal principle and a good valu
sintered filter Especially
Materials: Body: Aluminium, spring hood: Polyamide, diaphragm and seals: NBR, container: Polycarbonate
Temperature range: Up to max. +60°C
Input pressure: 1.5 - 10 bar (Pressure regulation range: 0.5 - 8.5 bar), media: Compressed air L
Pore width in the filter: 5 μm

ü Advantages: • Automatic venting in the event of overpressure on the secondary side


• Easy assembly of individual components from a particular model series using coupling kits
• Hand wheel can be locked by pressing down on it

H2
• Mounting brackets included in the scope of delivery
• Space saving compact pressure gauge already assembled
Flow Panel
Type Thread l/min L H1 H2 thread Model series
Manual drainage

H1
EiW 2000-02* G 1/4“ 1200 40 168 82 M 33 x 1.5 2
Semi-automatic drainage**
EiW 3000-03 G 3/8“ 2200 53 211 93 M 42 x 1.5 3
EiW 4000-04 G 1/2“ 5200 70 263 112 M 52 x 1.5 4
EiW 5000-10 G 1“ 6400 90 339 120 M 52 x 1.5 5
Automatic drainage with float**
EiW 2000-02D* G 1/4“ 1200 40 206 82 M 33 x 1.5 2
EiW 3000-03D G 3/8“ 2200 53 225 93 M 42 x 1.5 3
EiW 4000-04D G 1/2“ 5200 70 265 112 M 52 x 1.5 4
EiW 5000-10D G 1“ 6400 90 341 120 M 52 x 1.5 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.

Main dimensions - Filter regulators Eco-Line

A D E

B C

H 2

A D E
H2

B C
G

H 2
A D E
B C IN
H2

Thread
G

H 2
H1
H2

Thread
H1
F
H1

Thread

L I L I L I

EiW 2000 EiW 3000/4000 EiW 5000

Type Thread L H1 H2 A B C D E F G H I
EiW 2000-02 G 1/4“ 40 168 82 55 34 40 30 26 50 5,4 15,0 40
EiW 3000-03 G 3/8“ 53 211 93 53 40 53 39 32 46 6,5 8,0 61
EiW 4000-04 G 1/2“ 70 263 112 70 54 70 48 40 55 8,5 10,5 73
EiW 5000-10 G 1“ 90 339 120 70 54 90 48 45 62 8,5 10,5 84
EiW 2000-02D G 1/4“ 40 206 82 55 34 40 30 26 50 5,4 15,0 40
EiW 3000-03D G 3/8“ 53 225 93 53 40 53 39 32 46 6,5 8,0 61
EiW 4000-04D G 1/2“ 70 265 112 70 54 70 48 40 55 8,5 10,5 73
EiW 5000-10D G 1“ 90 341 120 70 54 90 48 47 62 8,5 10,5 84

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 4


Documentation Air units - Eco-Line

Filters Eco-Line e!
good valu
Version: Filtering using the centrifugal principal and sintered filter Especially
Materials: Body: Aluminium, container: Polycarbonate

ü
Temperature range: Up to max. +60°C L
Input pressure: 1.5-10 bar, media: Compressed air Advantages: • Easy assembly of individual components from a
Pore width in the filter: 5 μm particular model series using coupling kits

H2
Flow
Type Thread l/min L H1 H2 Model series
Manual drainage
EiF 2000-02* G 1/4“ 1250 40 95 11 2
Semi-automatic drainage**

H1
EiF 3000-03 G 3/8“ 2200 53 133 14 3
EiF 4000-04 G 1/2“ 5400 70 169 18 4
EiF 5000-10 G 1“ 8500 90 248 24 5
Automatic drainage with float**
EiF 2000-02D* G 1/4“ 1250 40 133 11 2
EiF 3000-03D G 3/8“ 2200 53 146 14 3
EiF 4000-04D G 1/2“ 5400 70 172 18 4
EiF 5000-10D G 1“ 8500 90 251 24 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.

Main dimensions - Filters Eco-Line

A
H2

Thread
A
H2

A
Thread
H1
H2

Thread
H1
H1

L B L B L B

EiF 2000 EiF 3000/4000 EiF 5000

Type Thread L H1 H2 A B
EiF 2000-02 G 1/4“ 40 95 11 40 40
EiF 3000-03 G 3/8“ 53 133 14 53 56
EiF 4000-04 G 1/2“ 70 169 18 70 73
EiF 5000-10 G 1“ 90 248 24 90 90
EiF 2000-02D G 1/4“ 40 133 11 40 40
EiF 3000-03D G 3/8“ 53 146 14 53 56
EiF 4000-04D G 1/2“ 70 172 18 70 73
EiF 5000-10D G 1“ 90 251 24 90 90

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 5


Documentation Air units - Eco-Line

e!
good valu
Especially
Mist lubricators Eco-Line L

Materials: Body: Aluminium, container: Polycarbonate


Temperature range: Up to max. +60°C

H2
Input pressure: 1.5 - 10 bar, media: Compressed air

ü Advantages: • Easy assembly of individual components from a particular model series using coupling kits
• Can be filled with oil while under pressure
Flow Max. oil

H1
Type Thread l/min volume cm³ L H1 H2 Model series
EiL 2000-02* G 1/4“ 1350 25 40 115 38 2
EiL 3000-03 G 3/8“ 2400 55 53 141 38 3
EiL 4000-04 G 1/2“ 5500 135 70 177 41 4
EiL 5000-10 G 1“ 8000 135 90 251 46 5
* delivered without a protective cage.

Main dimensions - Mist lubricators Eco-Line

H2
A

Thread
H2

Thread
H1
H2

H1

Thread
H1

L B L B L B

EiL 2000 EiL 3000/4000 EiL 5000

Type Thread L H1 H2 A B
EiL 2000-02 G 1/4“ 40 115 38 40 40
EiL 3000-03 G 3/8“ 53 141 38 53 56
EiL 4000-04 G 1/2“ 70 177 41 70 73
EiL 5000-10 G 1“ 90 251 46 90 90

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 6


Documentation Air units - Eco-Line

Air units, 2-part Eco-Line e!


good valu
Version: Filter regulator, resettable (with relieving system) with attached lubricator Especially
Materials: Body: Aluminium, spring hood: Polyamide, diaphragm and seals: NBR, container: Polycarbonate
Temperature range: Up to max. +60°C
Input pressure: 1.5 - 10 bar (Pressure regulation range: 0.5 - 8.5 bar)
Pore width in the filter: 5 μm
L
Media: Compressed air

ü Advantages: • Automatic venting in the event of overpressure on the secondary side


• Hand wheel can be locked by pressing down on it
• Mounting brackets included in the scope of delivery

H2
• Space saving compact pressure gauge already assembled
• Can be filled with oil while under pressure
Flow Max. oil
Type Thread l/min volume cm³ L H1 H2 Model series
Manual drainage
EiC 2010-02* G 1/4“ 1000 25 90 168 82 2

H1
Semi-automatic drainage**
EiC 3010-03 G 3/8“ 2000 55 118 211 93 3
EiC 4010-04 G 1/2“ 5100 135 154 263 112 4
EiC 5010-10 G 1“ 6200 135 195 339 120 5
Automatic drainage with float**
EiC 2010-02D* G 1/4“ 1000 25 90 206 82 2
EiC 3010-03D G 3/8“ 2000 55 118 225 93 3
EiC 4010-04D G 1/2“ 5100 135 154 265 112 4
EiC 5010-10D G 1“ 6200 135 195 341 120 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.

Main dimensions - Air units, 2-part Eco-Line

L A
D B

F
H2

L A
G

D B
E

L A
D B
F IN
E
H2

Thread
G

H1
H2

F
E

H
G

H1

Thread
E

E
H1

Thread
H
H

C C C
I I I

EiC 2010 EiC 3010/4010 EiC 5010

Type Thread L H1 H2 A B C D E F G H I
EiC 2010-02 G 1/4“ 90 168 82 54 27 30 45 24 5,5 8,5 5,0 57
EiC 3010-03 G 3/8“ 118 211 93 63 32 40 59 35 7,5 11,0 7,0 72
EiC 4010-04 G 1/2“ 154 263 112 80 40 49 77 39 9,5 13,5 7,0 90
EiC 5010-10 G 1“ 195 339 120 94 47 69 98 50 12,0 16,0 10,5 116
EiC 2010-02D G 1/4“ 90 206 82 54 27 30 45 24 5,5 8,5 5,0 57
EiC 3010-03D G 3/8“ 118 225 93 63 32 40 59 35 7,5 11,0 7,0 72
EiC 4010-04D G 1/2“ 154 265 112 81 40 49 77 39 9,5 13,5 7,0 90
EiC 5010-10D G 1“ 195 341 120 94 47 69 98 50 12,0 16,0 10,5 116

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 7


Documentation Air units - Eco-Line

Replacement parts for air units Eco-Line e!


good valu
Type Description Model series Especially
Replacement filters for filters and filter regulators
FiLTER Ei2000 5 μm 2
FiLTER Ei2000-25 25 μm 2
replacement filter
FiLTER Ei3000 5 μm 3
FiLTER Ei3000-25 25 μm 3
FiLTER Ei4000 5 μm 4
FiLTER Ei4000-25 25 μm 4
FiLTER Ei5000 5 μm 5
FiLTER Ei5000-25 25 μm 5
Replacement containers for filters and filter regulators, incl. O-ring
BF Ei2000 Manual drain 2
BF Ei2000D Automatic drain (float)* 2 replacement replacement
BF Ei3000 Semi-automatic drain* 3 containers for filters containers
and filter regulators for lubricators
BF Ei3000D Automatic drain (float)* 3
BF Ei4000 Semi-automatic drain* 4-5
BF Ei4000D Automatic drain (float)* 4-5
Replacement container for mist lubricator, incl. O-ring
BOL Ei2000 2
inspection glass
BOL Ei3000 3
BOL Ei4000 4-5
Replacement O-rings for sealing the container
OR Ei2000 2
OR Ei3000 3
OR Ei4000 4-5
replacement O-rings
Inspection glass for mist lubricator, incl. O-ring
TROPF EiL 2000 2
TROPF EiL 3000 3-5
Replacement pressure gauge 0 - 10 bar
MANO EiR 10 2-5
* as soon as the inlet pressure falls below the minimum input pressure, the drain valve opens.
replacement pressure gauge

Mounting brackets/coupling kits Eco-Line


e!
Type Model series good valu
Coupling kits incl. wall bracket Especially
KP EI2000 2
KP EI3000 3
KP EI4000 4
KP EI5000 5 coupling kit
Mounting brackets for pressure regulators and filter regulators
MW EI2000 2
MW EI3000 3
MW EI4000 4-5
Panel union nut for pressure regulators and filter regulators
SM EI2000 2
SM EI3000 3 for pressure regulators panel union nut
SM EI4000 4-5 and filter regulators
Mounting brackets for filters and lubricators
W EI2000 2
W EI3000 3
W EI4000 4
for filters and lubricators
W EI5000 5

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 8


Documentation Air units - Eco-Line

Main dimensions - Coupling kits incl. wall bracket Eco-Line


A

A
B

B
H

H
E

E
D G D G D G
C F C F
C F

KP Ei2000 KP Ei3000/4000 KP Ei5000

Type A B C D E F G H
KP Ei2000 48 24 15,0 5,5 9 29,5 5,0 32,5
KP Ei3000 70 35 16,0 7,0 11 41,0 7,0 45,0
KP Ei4000 78 39 22,0 9,0 13 49,5 7,0 50,0
KP Ei5000 100 50 24,5 12,0 17 68,5 11,0 62,5

Main dimensions - Panel union nut Eco-Line


B C
A

Type A B C D
SM Ei2000 M 33x1,5 42,2 7,0 40
SM Ei3000 M 42x1,5 54,5 6,0 51
SM Ei4000 M 52x1,5 63,4 6,5 60

Main dimensions - Mounting brackets Eco-Line

J
ØH

ØH
F

M
F
G

T
T

L
C
N
D
C

L
B B

A A

MW Ei ... W Ei ...

Type A B C D F G ØH J L M N T
MW Ei2000 55 34 25,0 19 50,0 30,0 33,0 --- 15,4 --- 5,4 2,3
MW Ei3000 53 40 21,5 14 64,0 39,0 42,0 --- 8,0 --- 6,5 2,3
MW Ei4000 70 54 27,0 18 79,2 49,2 52,0 --- 10,5 --- 8,5 2,3
W Ei2000 40 27 33,0 27 18,0 --- 4,5 26 8,4 14 5,4 2,3
W Ei3000 53 40 39,0 32 22,5 --- 4,5 35 8,0 19 6,5 2,3
W Ei4000 70 54 47,0 38 31,5 --- 5,5 47 10,5 20 8,5 2,3
W Ei5000 70 54 47,0 38 27,5 --- 5,5 47 10,5 20 8,5 2,3

All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.

Technical Consulting: +49 (0)5 61- 9 58 85 - 9 [email protected] 9