Documentation: Air Units - Eco-Line - Type Eir ..., Eiw ..., Eif ..., Eil ..., Eic ...
Documentation: Air Units - Eco-Line - Type Eir ..., Eiw ..., Eif ..., Eil ..., Eic ...
Documentation
1. Content
2. Operation manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
3. Articlenumbers and technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.1 Pressure regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Filter regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.5 Lubricators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.6 Air units, 2-piece . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
4. Spare Parts and equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2. Operation manual
1. SAFETY INSTRUCTIONS
• Warning! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
• Warning! Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
• Keep the equipment clean and maintain it in good condition (use an authorized service agent).
• Replace or repair damaged parts. Use genuine parts only. Unauthorized parts may be dangerous and will invalidate the warranty.
• Warning! Ensure that the correct air pressure is maintained and not exceeded.
• Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections are secure.
• DO NOT direct air from the air hose at yourself, others or animals.
• Drain the compressor air tank daily. Water in the air line will damage your equipment.
• When work is complete ensure that the air supply is turned off.
2. INSTALLATION
Air Supply
Outlet to the
Air Product
Filter Oiler
Regulator
The drawing shows a typical air line installation. The filter is located upstream of the regulator - unless combined- and the lubricator downstream.
Filter/regulator - Install using the mounting bracket provided. Before connecting system piping ensures that gauge is visible, unused gauge port is sealed with plug
provided and that flow direction arrow matches system air flow.
Filter and Lubricator - Install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that flow arrows are correct and
that filter is upstream, and lubricator downstream, of regulator.
3. OPERATION
Pressure regulators
The output pressure is controlled by the knob. Before pressurizing the air system for the first time, pull out and rotate the knob anticlockwise to remove any loading on
the regulator spring. Pressurize the system and then rotate knob clockwise to set required output pressure, as shown on gauge. When the required pressure is achie-
ved push in knob to prevent inadvertent adjustment.
For correct pressure setting always adjust up from a lower pressure. Therefore to reset from 90 to 70 psi for example, reduce pressure from 90 to 60 psi and then in-
crease to 70 psi.
Filter
The bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of the bowl, allow to drain and then re-
lease. Semi-automatic drainage and automatic drainage with float: As soon as the inlet pressure falls below the minimum input pressure, the drain valve opens.
Lubricator
Remove the filler plug and fill bowl up to max. level, with air tool oil. This can be done with the air line pressurised. With air flowing through the lubricator the oil deli-
very rate can be adjusted by screw whilst watching the drip rate through the sight dome. The oil delivery rate will automatically increase or decrease in line with the
air flow.
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
H2
• Mounting brackets included in the scope of delivery
• Space saving compact pressure gauge already assembled
H1
Flow Panel
Type Thread l/min L H1 H2 thread Model series
EiR 2000-02 G 1/4“ 1200 40 93 76 M 33 x 1.5 2
EiR 3000-03 G 3/8“ 2200 53 128 93 M 42 x 1.5 3
EiR 4000-04 G 1/2“ 5300 70 150 112 M 52 x 1.5 4
EiR 5000-10 G 1“ 6600 90 168 120 M 52 x 1.5 5
H
C
D
G I
F
H1
E
A
Thread
L B
Type Thread L H1 A B C D E F G H I
EiR 2000-02 G 1/4“ 40 93 17 55 31 34 44 5,4 15,0 55 2
EiR 3000-03 G 3/8“ 53 128 35 64 39 40 46 6,5 8,0 53 2
EiR 4000-04 G 1/2“ 70 150 38 81 48 54 55 8,5 10,5 70 2
EiR 5000-10 G 1“ 90 168 49 84 48 54 63 8,5 10,5 70 2
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
H2
• Mounting brackets included in the scope of delivery
• Space saving compact pressure gauge already assembled
Flow Panel
Type Thread l/min L H1 H2 thread Model series
Manual drainage
H1
EiW 2000-02* G 1/4“ 1200 40 168 82 M 33 x 1.5 2
Semi-automatic drainage**
EiW 3000-03 G 3/8“ 2200 53 211 93 M 42 x 1.5 3
EiW 4000-04 G 1/2“ 5200 70 263 112 M 52 x 1.5 4
EiW 5000-10 G 1“ 6400 90 339 120 M 52 x 1.5 5
Automatic drainage with float**
EiW 2000-02D* G 1/4“ 1200 40 206 82 M 33 x 1.5 2
EiW 3000-03D G 3/8“ 2200 53 225 93 M 42 x 1.5 3
EiW 4000-04D G 1/2“ 5200 70 265 112 M 52 x 1.5 4
EiW 5000-10D G 1“ 6400 90 341 120 M 52 x 1.5 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.
A D E
B C
H 2
A D E
H2
B C
G
H 2
A D E
B C IN
H2
Thread
G
H 2
H1
H2
Thread
H1
F
H1
Thread
L I L I L I
Type Thread L H1 H2 A B C D E F G H I
EiW 2000-02 G 1/4“ 40 168 82 55 34 40 30 26 50 5,4 15,0 40
EiW 3000-03 G 3/8“ 53 211 93 53 40 53 39 32 46 6,5 8,0 61
EiW 4000-04 G 1/2“ 70 263 112 70 54 70 48 40 55 8,5 10,5 73
EiW 5000-10 G 1“ 90 339 120 70 54 90 48 45 62 8,5 10,5 84
EiW 2000-02D G 1/4“ 40 206 82 55 34 40 30 26 50 5,4 15,0 40
EiW 3000-03D G 3/8“ 53 225 93 53 40 53 39 32 46 6,5 8,0 61
EiW 4000-04D G 1/2“ 70 265 112 70 54 70 48 40 55 8,5 10,5 73
EiW 5000-10D G 1“ 90 341 120 70 54 90 48 47 62 8,5 10,5 84
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
Filters Eco-Line e!
good valu
Version: Filtering using the centrifugal principal and sintered filter Especially
Materials: Body: Aluminium, container: Polycarbonate
ü
Temperature range: Up to max. +60°C L
Input pressure: 1.5-10 bar, media: Compressed air Advantages: • Easy assembly of individual components from a
Pore width in the filter: 5 μm particular model series using coupling kits
H2
Flow
Type Thread l/min L H1 H2 Model series
Manual drainage
EiF 2000-02* G 1/4“ 1250 40 95 11 2
Semi-automatic drainage**
H1
EiF 3000-03 G 3/8“ 2200 53 133 14 3
EiF 4000-04 G 1/2“ 5400 70 169 18 4
EiF 5000-10 G 1“ 8500 90 248 24 5
Automatic drainage with float**
EiF 2000-02D* G 1/4“ 1250 40 133 11 2
EiF 3000-03D G 3/8“ 2200 53 146 14 3
EiF 4000-04D G 1/2“ 5400 70 172 18 4
EiF 5000-10D G 1“ 8500 90 251 24 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.
A
H2
Thread
A
H2
A
Thread
H1
H2
Thread
H1
H1
L B L B L B
Type Thread L H1 H2 A B
EiF 2000-02 G 1/4“ 40 95 11 40 40
EiF 3000-03 G 3/8“ 53 133 14 53 56
EiF 4000-04 G 1/2“ 70 169 18 70 73
EiF 5000-10 G 1“ 90 248 24 90 90
EiF 2000-02D G 1/4“ 40 133 11 40 40
EiF 3000-03D G 3/8“ 53 146 14 53 56
EiF 4000-04D G 1/2“ 70 172 18 70 73
EiF 5000-10D G 1“ 90 251 24 90 90
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
e!
good valu
Especially
Mist lubricators Eco-Line L
H2
Input pressure: 1.5 - 10 bar, media: Compressed air
ü Advantages: • Easy assembly of individual components from a particular model series using coupling kits
• Can be filled with oil while under pressure
Flow Max. oil
H1
Type Thread l/min volume cm³ L H1 H2 Model series
EiL 2000-02* G 1/4“ 1350 25 40 115 38 2
EiL 3000-03 G 3/8“ 2400 55 53 141 38 3
EiL 4000-04 G 1/2“ 5500 135 70 177 41 4
EiL 5000-10 G 1“ 8000 135 90 251 46 5
* delivered without a protective cage.
H2
A
Thread
H2
Thread
H1
H2
H1
Thread
H1
L B L B L B
Type Thread L H1 H2 A B
EiL 2000-02 G 1/4“ 40 115 38 40 40
EiL 3000-03 G 3/8“ 53 141 38 53 56
EiL 4000-04 G 1/2“ 70 177 41 70 73
EiL 5000-10 G 1“ 90 251 46 90 90
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
H2
• Space saving compact pressure gauge already assembled
• Can be filled with oil while under pressure
Flow Max. oil
Type Thread l/min volume cm³ L H1 H2 Model series
Manual drainage
EiC 2010-02* G 1/4“ 1000 25 90 168 82 2
H1
Semi-automatic drainage**
EiC 3010-03 G 3/8“ 2000 55 118 211 93 3
EiC 4010-04 G 1/2“ 5100 135 154 263 112 4
EiC 5010-10 G 1“ 6200 135 195 339 120 5
Automatic drainage with float**
EiC 2010-02D* G 1/4“ 1000 25 90 206 82 2
EiC 3010-03D G 3/8“ 2000 55 118 225 93 3
EiC 4010-04D G 1/2“ 5100 135 154 265 112 4
EiC 5010-10D G 1“ 6200 135 195 341 120 5
* delivered without a protective cage. ** as soon as the input pressure falls below the minimum input pressure, the drain valve opens.
L A
D B
F
H2
L A
G
D B
E
L A
D B
F IN
E
H2
Thread
G
H1
H2
F
E
H
G
H1
Thread
E
E
H1
Thread
H
H
C C C
I I I
Type Thread L H1 H2 A B C D E F G H I
EiC 2010-02 G 1/4“ 90 168 82 54 27 30 45 24 5,5 8,5 5,0 57
EiC 3010-03 G 3/8“ 118 211 93 63 32 40 59 35 7,5 11,0 7,0 72
EiC 4010-04 G 1/2“ 154 263 112 80 40 49 77 39 9,5 13,5 7,0 90
EiC 5010-10 G 1“ 195 339 120 94 47 69 98 50 12,0 16,0 10,5 116
EiC 2010-02D G 1/4“ 90 206 82 54 27 30 45 24 5,5 8,5 5,0 57
EiC 3010-03D G 3/8“ 118 225 93 63 32 40 59 35 7,5 11,0 7,0 72
EiC 4010-04D G 1/2“ 154 265 112 81 40 49 77 39 9,5 13,5 7,0 90
EiC 5010-10D G 1“ 195 341 120 94 47 69 98 50 12,0 16,0 10,5 116
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.
A
B
B
H
H
E
E
D G D G D G
C F C F
C F
Type A B C D E F G H
KP Ei2000 48 24 15,0 5,5 9 29,5 5,0 32,5
KP Ei3000 70 35 16,0 7,0 11 41,0 7,0 45,0
KP Ei4000 78 39 22,0 9,0 13 49,5 7,0 50,0
KP Ei5000 100 50 24,5 12,0 17 68,5 11,0 62,5
Type A B C D
SM Ei2000 M 33x1,5 42,2 7,0 40
SM Ei3000 M 42x1,5 54,5 6,0 51
SM Ei4000 M 52x1,5 63,4 6,5 60
J
ØH
ØH
F
M
F
G
T
T
L
C
N
D
C
L
B B
A A
MW Ei ... W Ei ...
Type A B C D F G ØH J L M N T
MW Ei2000 55 34 25,0 19 50,0 30,0 33,0 --- 15,4 --- 5,4 2,3
MW Ei3000 53 40 21,5 14 64,0 39,0 42,0 --- 8,0 --- 6,5 2,3
MW Ei4000 70 54 27,0 18 79,2 49,2 52,0 --- 10,5 --- 8,5 2,3
W Ei2000 40 27 33,0 27 18,0 --- 4,5 26 8,4 14 5,4 2,3
W Ei3000 53 40 39,0 32 22,5 --- 4,5 35 8,0 19 6,5 2,3
W Ei4000 70 54 47,0 38 31,5 --- 5,5 47 10,5 20 8,5 2,3
W Ei5000 70 54 47,0 38 27,5 --- 5,5 47 10,5 20 8,5 2,3
All data are considered to be unbinding reference values. We accept no liability for data selection that is not confirmed in writing. Pressure data refer, if not otherwise indicated, to liquids of Group II at +20°C.