000 LSGD Rules Check List
000 LSGD Rules Check List
ON
Amature winding shops, tailor shops, beaty parlour, pathological labs
Group C.D area not more than 150m2 Group E,H area not more than 300m2
APPROVALS REQUIRED:
TI
RULE NO. APPROVAL FROM CONDITIONS REMARKS
4 (1.2) Local Self Government All buildings /Structures
CIA
28(vi) 54(6) DTP Lay out of all new commercial streets
land sub division exceeding 5 plots
56 Building floor area exceeding 3000m2
- 6000m2
SO
CTP Above 6000m2
6A N.O.C from DGP Land development in security zone
District collector AS
56(3j), 56(5) Fire Force, N.O.C Parking bldg.- Above 3 floors/ other
All requirements mercantile bldgs. Above 2 floors
Air , water N.O.C For high rise building
Pollution control board If discharge of effluents is high
RS
If generator provided
32(2) Airport authority Within 22 km radius of Airport N.A for parking
reference point parking bldg.
EE
additional 3m
10m ht.
Rear Min. 1.5m
LS
ON
height of bldg. All around building
more than 15m or
4 floors
24(2) Min.Space between Upto 10m ht. 2m
TI
bldgs.in same plot Above 10m ht. 3m
100(4) Min.space between Septic tank and boundary 120m
104(1) Set back of well from road- same as for the bldg.
CIA
Other sides 1.5m
56(1) D.T.P Approval layout of building exceeding
6000m2
C.T.P Approval layout og bldg. exceeding 6000m2
SO
56(1a) Side yards Except high rise building side yards may Commercial zone
not be provided for bldg. under group-F for T.P. scheme
window or ventilator such other opening is
AS
invisaged on any side of bldg. have 1.50m
104(3) Well & bldgs. in Can abut/inside bldg. Nil See well Rule No.
the same plot 103-109
104(4) Dist. of Well from 7.5m
RS
septic tank etc.
Dist. of septic tank 1.2m
etc. from boundary
EE
Sanitary facilities
No. of person 1 person per 4.75m2 carpet area *Carpet area 80% of
Male 2/3 of total floor area OR
Female 1/3 of total *Actual usable carpet
area (Ref.Definition)
LS
ON
Bathroom+WC Min. area 2.2m2 , min. width 1.10m
24(6) Interior open space Bldgs. with 7m. ht 1.5m
Min.width Bldgs with 10m ht. 2.4m *For habitable room
TI
24(7) Unpaved yard (For percolation of rain water) Can drain rain water to
If permeable soil Required public drain if
If impermeable soil Not req. impermeable
CIA
24(11) Roof/Shade Min.open space req. Roofprojection allowed
projection Less than 0.60m Not allowed
0.60 m 0.30 m
SO
0.75 m
1.00 m 0.60 m
1.50 m 0.75 m
26 Use of open space Roof projection to open space of 3 m 75 cm
abuting road
Min.dist. between
AS
Ramp. star, bridge etc can construct
Road widening/ bldg. line
central line of 5m should be considered
road & bldg *Applicable to all sides
RS
25(1) Min.dist.between Upto 10 m ht. 3m 5m distance between
plot boundary & For bldg upto 7m height centerline and building
bldg. cul-de-sac not exceeding 250m (all road width) not applicable
EE
26A Disposal of waste There shall be provisions for safe disposal of waste
11A Earth work Excavation more than 1.50m Details in R.11A(1)-12
31 Coverage Table 2 60% * Car perking area inside
EN
building/accessory
bldg. exempted for
31(2) F.A.R Without addl. fee 2.00 F.A.R. calculation
GD
ON
Rule Occupancy Total floor area of bldgs. in sq.m Number of storeys Minimum width
No of access rqd. in m
33(1) Occupancies Upto 300 Single storey 1.2
a other than Above 300 upto 1000 Two storey 3.6
TI
Group A1 Above 1000 upto 4000 Three storey 5
Ref.R28 Above 4000 upto 8000 Four storey 6
CIA
also Above 8000 upto 12000 Above four storey 8
Above 12000 10
Parking 2nd grade municipality
34(1) Carparking Up to 75m2 carpet area N.A 3rd grade Mun./
SO
(2)6 (5.5x2.7m -15m2) exceeding 75m2 Panchayath 50%
table 1 parking soace for 75sq.m carpet area Carpet area =80% of
5 upto 1000m2 and1 per 50m2 in excess of 1000m2 floor area
AS (ref.defition)
34(3) Two wheeler 25% of car parking area
parking area
34(7) Parking in 50% of mandatory open space
open area
RS
34(6) loading/ Upto 700m2 floor area N.A
unloading Above 700m2
space of No.of loading space=
(30m2) 1 for each 1000 sq.m exceeding 700sq.m
EE
garage
2/(vi) Layout Exceeding five plots CTP
from CTP
39 Stair case
LS
39(1) Min.no.of stairs For above 4 floors 2 nos. 1 stair may be external
39(2) Width Min. 120 cm Including sunken floor
39(3) Tread Min.30cm
39(4) Rise 15 cm
39(5) Ht. of handrail Not less than 90 cm
ON
41 Width of coridor Min.100 cm 100 cm
Varandah.
42(1) Fire escape Upto 2 floor Nil
stair nos. Above 2 floor required
TI
42(2) Width Min .75cm
Tread Min.15cm
CIA
Rise Max.19cm
No.of riser Max.16 nos.
42(3) Ht. of handrail Min.100 cm
42(4) Position Exterior of building
SO
42(5) Flight Straight
42(6) Entrance Separated from internal stair
43(2) Travel distance AS
to fire escape Max.30m
114(6) Spiral stair Max. ht. of bldg 10m *Only for low occupancy
47(1) 9m group
114(7) Min.diametre 150cm *Should have enough
RS
47(2) head room
44 For protection
requirement As per NBC
EE
Door (No.of unit door width of 50cm = Gross area unit exit width of 50cm
of the floor ÷ (75x12.5) for stair 60 Door-90
GI
ON
49(4) Ventilation in kitchen
ventilated as in habitable room Refer NBC
Suitable flue to be provided
49(6) Air shaft for No.of floors Size & Area Not required if
TI
ventilation Up to 3 0.90 1.08m2 centrally
4 to 6 1.2 2.40m2 Air conditioned
CIA
7 to 10 1.5 3.0m2
Above 10 2.0 5.0m2
Clearance from Overhead Electric Lines - Clearance from building See R23(5),Table1
109A RAIN WATER HARVESTING
SO
109B Rain water 25 litre per Sq.m of floor area Group A1,A2,B
storage tank C,D,E,F
110 High rise More than 4 floor/15 m heightAS R.110-120B See page No.248
building
112(i) Stair Case At least two stair cases
(ii) handrails Height of handrail shall not be less than 90cm.
RS
and the balusters shall be more than 10cms wide
113 Guard rails Height less than 1.20 metres
EE
or parapets
114 Fire escape Shall be provided Fire escape way
Fire escape stairway directly connected with
N
stairway
floors and directly to the ground
GI
ON
Various blocks 5m
Width passage way and entrance 7m
118 Lift for residential Morethan 16 dwelling units,carrying structure
TI
apartments
119 Parapet of Parapet walls height 120cms
Terance floor
CIA
120 Structural design Structural stability certificate issued by 1 set
drawing registered engineer
56(3) Parking bldg./Plazas/towers permitted at any
SO
zone of parking building
56(3a) Open spaces All sides 5m all height(No.addl.set
AS back
Appurtenant bldg For bldg. upto 10m ht.
for parking For parking bldgs. constructed at the same *Addl.set back@ 50cm
purpose of plot of other bldg for every Addl. 3m ht.
RS
56(3d) main building Side abutting street - 3m Min. or Min.set back over 10m.ht.subject to a
Required for the main bldg. whichever is less max. set back of 5m
Sides 1m
EE
56(3i) Slope
Ramp Width
Strength All values should be
Size sufficient
Lift Strength