for DLMS smart meters
Menu
Home Forums Communicating With Secure Saral Over DLMS Using Pyhon
Communicating with
Secure Saral over
DLMS using pyhon
Forum Rules
Before commenting read Forum rules
Don't comment the topic if you have a new question.
You can create a new topic selecting correct category from Gurux
Forum and then create a new topic selecting "New Topic" from the top
left.
By anildhyani82, 25 December, 2020
Forums
Gurux.Serial
Hi,
I am trying to communicate with Secure Saral meter using Gurux client
library . Interface used is Serial.
Mikro Usb on Meter to Db9. Parameters i used are following:
a) Server Address : 3
b) Client Address : 32
c) Password : ABCD0001
d) Type of Addressing : Logical
e) Logical Server : 1
f) Authentication Type : Low
Tried with different possible combinations but no success.
It tries to send SNRM packet and gets failed over there. Basically time-
out happens . So i am not sure why this is happening. Has any one
worked / communicated with this meter.
GXDLMSDirector 8.1.2012.1701
Log created 20:09:40
20:09:44 Initializing serial connection.
20:09:44 08:09:44.366 Info Opening
20:09:44 08:09:44.366 Info Serial Port Settings: Port Name: COM4 Baud
Rate: 9600 Data Bits: 8 Parity: None Stop Bits: One Flow Control: None
Eop: None
20:09:44 08:09:44.369 Info Open
20:09:45 Send SNRM request.
7E A0 08 02 03 23 93 36 54 7E
20:09:45 08:09:45.370 Sent 7E A0 08 02 03 23 93 36 54 7E
20:09:45 08:09:45.384 Received 7E A0 08 02 03 23 93 36 54 7E
Data send failed. Try to resend 1/3
I have tried using DLMS director GUI utility also but results are same.
Looking for some valuable inputs.
Thanks
Kurumi 4 years 2 months ago
Hi,
Hi,
Try to change server address to 1. You are receiving an echo from the serial port.
Check also your serial port settings from the meter documentation.
BR,
Mikko
Vamsidhara Reddy 11 months 1 week ago
Hi Anil, Where you able to…
Hi Anil,
Where you able to connect to the Saral meter if yes let me know which DB9
connector you used.
Log in or register to post comments
Username
Password
Log in
Create new account
Reset your password
Latest Releases
Mon, 03/10/2025 - 09:21
gurux.dlms.cpp 20250310.1
Thu, 03/06/2025 - 08:27
Gurux.DLMS.Net 9.0.2503.0601
Wed, 03/05/2025 - 13:07
gurux.dlms.cpp 20250305.1
Wed, 03/05/2025 - 10:11
Gurux.DLMS.Net 9.0.2503.0501
Mon, 03/03/2025 - 09:09
gurux.dlms.c 9.0.2503.0301
New forum topics
Wrong SetRequest after latest update
How to use object methods?
SL7000 AC VOLTAGE L1-L2
CSR Invalid Counter
Parse meter's push data
More
Who's new
D@faizan4321
DarrekonTrure
Charleseton
GictorGrala
Wayneimach
RSS feed
Privacy FAQ GXDN Issues Contact