UOP CCR Platforming
UOP CCR Platforming
UOP 4474F-02
Market Drivers
◼ Product demand:
– Tight supply for gasoline in the US
– Benzene and Xylene
◼Specification drivers:
– Desulfurization in transportation fuels
– Increased octane for gasoline in Asia
◼ Efficiency:
– Improve feed utilization
– Reduce costs per BBL
UOP 4474F-03
191 Operating CCR Platforming Units
37 in Design and Construction
Commissioned CCRTM ◼ First generation ➔ Atmospheric
Regenerators Types
Pressurized
◼ Second Generation ➔ Pressurized
24 Sequential
CycleMaxTM 1 ◼ Current state of the art high
41 capacity regeneration ➔
CyclceMaxTM
◼ Newest small capacity regenerator
➔ Sequential
Atmospheric
125
20,000 – 30,000
74 units
Optimized vapor
distribution results in best
catalyst utilization UOP 4494B-13
Improved Reactor Upflow Centerpipe
Machine Socket
Most reliable mechanical assembly. (Female End)
Ensures best utilization
of catalyst
UOP 4474F-09
Reduction
Zone Smooth Catalyst Movement
◼ Only 2 lifts
◼ Straight upward lift lines
◼ Horizontal flow – only at
downward slope
Last ◼ No operating valves in
Reactor
catalyst lines
◼ Smooth flow control with
Catalyst
Collector unique L-valve
Lock
Hopper
◼ “Impactless” elbows
Booster
N2 Gas H2
60
◼ Current design ranges
are 12,000 to 95,000+
40 BPD
20 ◼ Careful attention to
design is critical
0
1970s 1980s 1990s 2000s
Premier regenerator
UOP 4474F-14
CycleMax Regenerator Burn Zone
Feature Benefit
Tapered screen : ◼ Maintains good Pt
Shorter residence time at dispersion
peak temperature ◼ Ultra-long catalyst life
Low O2 concentration: ◼ Ultra-low fines production
Low peak burn Special
Thermocouples
temperature
90.00
10.0
85.00 0.0
-10.0
80.00
-20.0
75.00
-30.0
70.00 -40.0
Over 8 years
Catalyst
Transfer Pipes
Disengaging
Vent Gas ◼ Caustic scrubbing is
Hopper
Catalyst
< 30 ppm HCl outdated
◼ Chlorsorb system
Chlorsorb results in:
Vessel – No waste water
– Minimal chloride
Regeneration Burn Zone injection due to
Tower Gas extensive chloride
recycle
97
96
95
94
93
92
91
90
TCDD I-TEF CL-BZ PCB HCL Total
CCR Regenerator Vent Gas Compounds
Operating
Design and
construction
Successfully Operating
◼ 4 CycleMax regenerators
◼ 11 Atmospheric regenerators
UOP 4474F-23
R-264 Catalyst Benefits
One Catalyst – Two Operating Modes
Maximum Yield Mode
◼ ~0.6 wt% yield advantage
◼ ~ 7 Nm3/m3 Hydrogen
◼ Same activity as R-134 catalyst
R-264 catalyst
R-234 performance line
Yield
R-264 High
R-134 Activity Mode
Activity
UOP 4474F-25
Third Party Catalyst Testing
R-264, R-134, Competitor Catalyst
◼ Catalyst “A” has poorer selectivity to H 2, C5+, and
aromatics than R-264 or even R-134 catalyst
◼ R-264 catalyst exhibits better selectivity
– R-264 catalyst has a large selectivity advantage
over competitor’s catalyst A
– Selectivity advantage increases with lower
pressure and higher severity
◼ R-264 catalyst shows
– More C5+
– More aromatics and hydrogen
– Less A6 and more A8+
UOP 4474F-26
3rd Party Evaluation
R-264, R-134, Competitor Catalyst
UOP 4474F-27
R-264 Catalyst – Physical Properties
◼ More open pore structure – higher throughput
operation
– Low coke
– Faster burning rate
◼ Higher density
– Higher pin margin for more throughput
◼ Higher strength
– Lower fines make
◼ Surface area stability
– Catalyst life equal to the best in the industry
(R-134)
UOP 4474F-28
R-264 Commercial Status
◼ 8 refiners have selected R-264
– 6 are in operation
– 1 more will load 4th quarter 2005
– 1 will load 1st quarter 2006
◼ A commercial example
– Switched from R-134 ( nearly 10 years old)
– Wanted flexibility for high selectivity or activity
– Immediate need for more reformate
UOP 4474F-29
R-264 Catalyst
Feed & Operating Conditions
P/N/A, lv% 43/36/21
IBP / 50% / EP, °C 99/127/179
RONC Typical 99-100
R-264 Catalyst Mode High Activity
UOP 4474F-30
R-264 Catalyst Commercial Performance
Improved Yields
C5+ Yield H2 Yield
90 1400
C5+ Yield, LV% H2 Yield
89 1300
C5+ Yield, LV%
H2 Yield, SCFB
88
R-134 1200
87
86 1100
85 1000
84 R-134 R-264
83 R-264 900
82 800
12/9/04 12/19/04 12/29/04 1/8/05 1/18/05 1/28/05 2/7/05 12/9/04 12/19/04 12/29/04 1/8/05 1/18/05 1/28/05 2/7/05
Date Date
995
2.15
11º C more active 990
LHSV, 1/hr
WAIT, °F
985 R-264 Catalyst
R-134 Catalyst 2.10
980
30
R-134 Catalyst
25
20
15
R-264 Catalyst 50% less fines make
10
5
0
12/9/04 12/19/04 12/29/04 1/8/05 1/18/05 1/28/05 2/7/05
R-264 catalyst is more active with
lower fines make!
UOP 4474F-32
R-264 Catalyst Commercial
Performance Summary
◼ Activity increased by ~ 11°C
◼ C5+ yield increased by ~ 1-2 lv %
◼ Hydrogen yield increased by ~ 20 NM3/m3
◼ Chloride use reduced by ~70%
◼ Fines make reduced by 50%
UOP 4474F-35
Summary Cont’d
UOP continues to innovate and improve
the Platforming process
– UOP has the skill and experience to design
CCR Platforming units to meet the needs
of all markets
– R-264 catalyst is the highest performance
catalyst available today
UOP 4474F-36
UOP 4474B-37