Wires
Cables
A cable is, generally, two or more wires running together or bonded, twisted or
braided together. They are mostly insulated to offer better protection than just
wires. Cables are largely employed in power transmission, and to carry electrical
and telecommunications signals. There are many types of cables, such as, twisted
pair cable, coaxial cable, multi-conductor cable, and fiber optic cable. If we talk
about the twisted pair cable, it comprises two cables twisted around each other,
and is mostly used for carrying signals.
Wires Cables
Types Solid wire, and stranded wires Twisted pair cable, coaxial cable,
multi conductor cable and fiber optic
cable
Advantage solid wires are perfect for use in Higher strength, heavy duty,
higher frequencies, offer low insulated.
resistance. Stranded wire shows
higher resistance to metal fatigue.
They are
• Cleat wiring.
• Batten wiring.
• Casing and caping.
• Conduit wiring.
1. Cleat wiring
In this type of wiring, the insulated conductors are supported on porcelain or
wooden cleat. The cleats have two halves.
One base and another cap. The cables are placed in groves in the base plate and a
cap is placed on it.Cables are held in porcelain or wooden cleats at 6mm above
the walls or ceiling.
Cleat wiring is generally used for temporary wiring purposes not as a permanent
system of wiring. It is not preferred on domestic premises. But, it is quite suitable
for taking a temporary connection in industrial construction work.
Advantages
2. Batten Wiring
This wiring system is a very old method in which all wires are tied with an iron
clip on top of a wooden strip (batten) and this collection is used in large
quantities so that the wire is very well sealed with some wooden strip.
Thisthen
and clip by
is like
laying
a belt
wires
to aonwristwatch.
top of the strip,
Whichit is placed
tied well
onwith
top of
this
theclip.
first strip
Advantages
This type of wiring is very popular. Because this wiring system is very easy to
do and it is also very cheap.
If it is done above the walls, then anyone can fit it very easily in this wiring
fitting, the wires are placed inside the plastic casing or wooden enclosures.
It is a more
looks kind of
secure.
open fitting it is covered from the top so that it looks good and
Advantages
• This wiring system is much easier and cheaper than other wiring systems.
• This wiring system is very strong and long-lasting.
• One can make changes to this wiring very easily.
• There is no risk of electric shock as it covers the wires well.
• If phase and neutral follow a different path, repair becomes easy.
Disadvantages
• if there is a fire in the wires inside it, then this whole fitting can burn.
•
4. Conduit Wiring
1. Surface mounting.
2. Concealed conduit wiring.
Surface mounting conduit wiring system
Conduits carrying the PVC insulated wires can be installed on the surface of the
walls or concealed in the walls and the ceiling.
Conduit wiring is a system, basically, wires or cables which are routed in metal
or plastic inside the wall.Conduits isolate wires to avoid exposure, thereby
reducing the risk of fires, short circuits, fire, electrocution.
Modern practice is the hidden installation of the conduit in the plaster of the
wall, so that appearance of the house or the building remains unaffected.
Conduits are available in standard lengths.
The conduits system for each circuit must be erected completely before any
cable is drawn in.
Advantages
Types of Switches:
The switch is an electrical device that is used to break or make an electrical circuit manually
or automatically. The working principle of switch depends on ON/ OFF mechanism. Various
electrical or electronic circuits use switches to control or trigger the owl circuit. The types of
switches depend on the connections of the circuit they make. Two essential components such
as pole and through can confirm what types of connections a switch can make. These two
components are also used to define variations of switch contact.
Here, the poles and throws can be defined as; when the number of circuits is controlled by a
switch is called poles, whereas throws can be defined as the number of positions that the switch
can adopt. A single throw switch consists one pair of contacts like open or close. A double
throw switch includes a contact, which can be connected to two other contacts. When the switch
is activated, then the current flows through between the two terminals of the switch. When the
switch is OFF, then the current doesn’t flow between the two terminals of the switch.
The SPST is a basic ON/OFF switch, that is used to connect or break the connection between
two terminals. The power supply for the owl circuit is given by this switch. A simple PST
switch is shown below.
The application of SPST switch is light switch given below and it is also called as a toggle
switch. This type of switch has one input and one output. This light switch circuit controls one
wire and makes one connection. This is an ON/OFF switch, when the switch in the below
circuit is ON or closed, then the current flows through the two terminals and the bulb in the
circuit will blink. When the switch is OFF or open, then the current doesn’t flow through the
two terminals.
The SPDT switch is a three terminal switch, one terminal is used as input and remaining two
terminals are used as outputs. It joins a mutual terminal to one or the other of two terminals. In
the SPDT switch, instead of other terminals, just use COM terminal. For example, we can use
COM & A or COM & B.
The application of SPDT switch is mainly involved in a three-way circuit to turn ON/OFF a
light from two locations like from the top & bottom of a stairway. In the circuit below, when
the switch A is closed, then the current flows through the terminals, but only light A will glow
and light B will OFF. When the switch B is closed, then the current flows through the terminals
and only light B will glow and light ‘A’ will OFF. Her two circuits will be controlled through
one source or one way.
The DPST switch consists of two poles that means it includes two identical switches located
on side by side. This switch is operated by one single toggle, which means that two discrete
circuits are controlled at a time through one push.
This switch is used to turn two circuits ON/OFF and it consists of four terminals namely two
inputs and two o/ps. The main purpose of this switch is to regulate a 240V appliance, where
both supply voltages must be ON whereas the unbiased wire may be always connected. When
this switch is ON then the current starts flowing through two circuits and when it is turned OFF
then it is turned OFF.
This switch is equal to two SPDT switches, it means two separate circuits, connecting two
inputs of each circuit to one of two outputs. The switch position controls the number of ways
and from the two contacts each contact can be routed.
When it is in ON-ON mode or ON-OFF-ON mode they work like two discrete SPDT switches
worked by the similar actuator. At a time only two loads can be ON. A DPDT switch can be
used in any application that needs an open & closed wiring system.
The best example of this is, modeling of the railroad, that makes use of small scaled railways
and trains, cars and bridges. The closed permits for the system to be switched at all times,
whereas open permits for extra piece to be switched ON or triggered through the relay. From
the following circuit, A, B and C connections from one pole of the switch and D, E and F
connections from the other pole of the switch. Connections B and E are mutual in each of the
poles.
If the +Vs enters at connection B & the switch is fixed to the top most position, then the
connection A becomes +ve and the motor will rotate in one direction. If the switch is set to the
lowest position, the power supply is inverted and connection D becomes +ve then the motor
will rotate in the opposite direction. In the middle position, the power supply is not linked to
the motor and it does not rotate. This kind of switch is mainly used in several motor controllers
where speed of that motor is to be inverted.
The electrical potential of the Earth is considered to be zero. Hence on connecting the electrical
channels of any appliance to the Earth, its potential would become zero too.
This is the main concept behind Earthing, which is a process bonding noncurrent bearing parts
of an electrical device or the neutral summit of the electrical organization to the earth through
wires possessing minor resistance to flow of current.
We know that current flows from a higher to a lower potential. Any electrical appliance or any
electricity line which has been connected to the earth is now at zero voltage.
In the case of any overloading of current, the immediate discharge of electrical energy takes
place to the ground, without harming the appliance or the user.
Even if the insulation of the equipment fails, if it is earthed, the appliance is safe enough.
Methods of Earthing
There are several common methods employed for earthing of appliances, and each of them is
used according to the site of the building, the type and number of appliances to be earthed, the
budget and other such factors. Here are a few of them.
Plate Earthing
A 2.5 metre deep pit is dug into the ground and a Galvanised Iron (GI) plate is placed inside
along with charcoal and sand for the purpose of maintain low resistance around the plate.
An earth wire, which is of GI or tinned copper, is bolted to the plate before burying it by means
of nuts, bolts and washers. The wire is made to pass through a GI pipe through which some
water is poured in to increase conductivity. The earth wire is connected to the Earth point of
the socket and is finally covered.
Pipe Earthing
A 2.5 metre long pipe measuring about 35-75 mm in diameter is buried in the dig out pit along
with sand and charcoal. The pipe is provided with several perforations to maintain dampness
around and hence conductivity.
The earth wire is tied and clamped near the summit. Water may be poured into it during
summers. The earth wire is safer against damage in such a setup.
Pipe Earthing
This method employs hammering of zinc and copper rods of about 1-1.5 metres length and
12-20 mm diameter into the general mass of the earth.
Successive rods are screwed together and this chain is tried making as long as possible for
lowered resistance by the surrounding soil.
The earth wire is tied and clamped near the summit. This is a very economical and quick
procedure for earthing.
MCB vs MCCB
MCB MCCB
These are used for low energy requirements MCCBs are used in high energy requirement applications
such as small electronic circuits or home such as high-power equipment in industries or for
wiring. commercial purposes.
MCBs have ratings under 100 amps. MCCBs goes as high as 2500 amps.
Interrupting rating under 18000 amps. Interrupting rating ranges from 10000 to 200000 amps.
Staircase wiring
Staircase wiring is a common multi-way switching or two-way light switching connection; one
light two switches wiring. Here one lamp is controlled by two switches from two different
positions. That is to operate the load from separate positions such as above or below the
staircase, from inside or outside of a room, or as a two-way bed switch, etc.
Staircase wiring circuit arrangement
The first pole and second pole of the SPDT switch S1 is connected to the corresponding first
and the second pole of the SPDT switch S2. That is similar poles of both two switches are
connected to each other.
The phase of the supply line is connected to the common pole of a switch. And the phase line
to the load is taken from the common pole of the next switch. It makes an arrangement that, to
close the circuit both the switches should be in the same position in order to make the two
common poles in contact to achieve a closed circuit. Changing the ON & OFF condition of a
single switch can determine whether the circuit is closed or open. Thus in staircase wiring, we
can control the load from both positions. If a truth table is made for the above traveler system
output, it will have a result similar to an XNOR gate. That is the light ON’s when both the
switches are in the same position.
Similarly, if the connections between the switch s1 and s2 have interchanged, the load will ON
when the switches have opposite positions.