Solution Ultima 862 Quick Reference Guide
Solution Ultima 862 Quick Reference Guide
ISSUE 1.70
2 Solution Ultima 862 Quick Reference Guide
This documentation is provided to suit the Solution Ultima 862 control panels.
Firmware Revision 1.00 – 1.09
Hardware Revision A - J
Alarm Link required = 2.74 or higher
Control Panel Software Version 1.00 – 1.09 = S486_V10
Copyright Notice
All rights reserved. No part of this publication may be reproduced, transmitted or stored in a retrieval system in
any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior
written permission of Bosch Security Systems Pty Limited.
Trademarks
Throughout this document trademark names may have been used. Rather than put a trademark symbol in every
occurrence of a trademark name, we state that we are using the names only in an editorial fashion and to the
benefit of the trademark owner with no intention of infringement of the trademark.
Notice of Liability
While every precaution has been taken in the preparation of this document, neither Bosch Security Systems Pty
Limited nor any of its official representatives shall have any liability to any person or entity with respect to any
liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this
book.
Bosch Security Systems Pty Limited reserves the right to make changes to features and specifications at any
time without prior notification in the interest of ongoing product development and improvement.
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 3
Introduction
Thank you for choosing the Solution control panel for your installation. We are sure that you will
find this system extremely flexible, reliable and easy to use. The quick reference guide is supplied
with the system to provide users with enough basic information to wire, configure and program the
system. Due to the systems many programmable features and options, we suggest that you obtain
the complete installation manual that provides detailed information on system options and functions
and programming methods.
Programming
The programming options of the system are stored in a non-volatile EPROM. This memory will
hold all information during a total power loss and can be changed as many times as required.
In general, the entire programming sequence will consist of entering a location number and then
change the data as required.
• Codepad
• Hand Held Programmer
• Alarm Link Software
To enter installer’s programming mode, enter the installer code (Default = 1234) followed by the #
key. Two beeps will be heard and both the STAY and AWAY indicators will flash simultaneously to
indicate that you have entered programming mode. The codepad indicators will display the current
data programmed in LOCATION 000 (First location of the Primary Telephone Number).
To move to another programming location, enter the location number followed by the # key. The
data in the new location will now be displayed via the codepad indicators (eg. If you entered 34#,
the system will jump you to LOCATION 034, the beginning of the Subscriber ID Number For
Receiver 1).
To move to the next location, press the # key. This will step you to the next location. The data in
the next location will now be displayed via the codepad indicators (eg. If you are currently
positioned at LOCATION 034, pressing the # key will take you to LOCATION 035).
To step back one location, press the * key (eg. If you are currently positioned at LOCATION 35,
pressing the * key will take you back to LOCATION 34).
To change data in the current location, enter the new value (0 – 15) followed by the * key. This will
store the new data into the location and leave you at the same location (eg. If you enter the value
14*, both the Zone 4 indicator and the MAINS indicator will display to represent the new data
value).
To move to the next location, press the # key. The data in the next location will now be displayed.
To exit Installer’s Programming Mode, enter 960#. Two beeps will be heard and the STAY and
AWAY indicators will no longer display. The system has now returned to the disarmed state and is
now ready for use.
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
4 Solution Ultima 862 Quick Reference Guide
Codepad Indicators
Data Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 MAINS
Value Indicator Indicator Indicator Indicator Indicator Indicator Indicator Indicator Indicator
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X X
10 X
11 X X
12 X X
13 X X
14 X X
15 X X
Example
If at LOCATION 177 you only want options 1, 2 and 4, add the numbers together and the total is
the number to be programmed. In this example, the number to be programmed is 7 (eg. 1 + 2 + 4
= 7).
Option Description
1 Dialler Reporting Functions Allowed
2 Remote Arming Via Telephone Allowed
4 Answering Machine Bypass Only When Armed
8 Use Bell 103 For FSK Format (Disabled = CCITT V21)
Command Description
958 Enable/Disable Zone Status (Hand Held Programmer Required)
959 Test Programming Key
960 Exit Installer’s Programming Mode
961 Default System Back To Factory Settings
962 Copy Panel Memory To Programming Key
963 Copy Programming Key To Panel Memory
964 Erase Programming Key
965 Default System For Domestic Dialling Format
966 Enable/Disable Automatic Stepping Of Locations When Programming
999 Display Software Version (Hand Held Programmer Required)
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 5
2. Enter your code followed by the # key. Repeat step 2 if more than one zone is
[eg. 2580 + #]. required to be isolated.
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
6 Solution Ultima 862 Quick Reference Guide
2. Enter the Number Of Days (0 – 15) to wait 2. Enter the User Number (9 – 16) that you want
until first test report followed by the # key. to add followed by the # key.
2. Press and hold the 9 key until two beeps are 2. Enter the Output Number (1 – 3) that you
heard to send a test report. want to toggle on or off.
Zone LED Dialling Event 3. Press the # key to toggle On or the * key to
1 Telephone Line Seized toggle Off.
2 Dialling Telephone Number
3 Handshake Received 4. Press the # key to exit.
4 Data Being Sent
5 Kiss-Off Received
None Released Telephone Line Setting Date and Time
1. Enter the Master Code followed by 6 and the
# key [eg. 2580 + 6 + #].
Add A User Code
1. Enter the Master Code followed by 1 and the 2. Enter the day (DD), month (MM) and year
# key [eg. 2580 + 1 + #]. (YY) followed by the hour (HH) and minute
(MM).
2. Enter the User Number (1 – 8) that you want
to add / change followed by the # key. 3. Press the # key to exit.
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 7
Zone
Strobe Test (Toggle On/Off)
FAULT Condition 1. Press and hold the 3 key until three beeps are
LED
Press and Hold Button 1 heard to turn the strobe on.
To Determine Fault
1 = Battery Fail 2. Press and hold the 3 key until two beeps are
2 = Date/Time heard to turn the strobe off.
3 = RF Rx Jamming
RF Rx Tamper
1 System Fault
RF Rx Comm’s Fail
4 = Horn Speaker Fail Telco Arm Sequence (Call Forward On)
5 = Telephone Line Fail 1. Enter your Installer Code or Master Code
6 = E2 Fail followed by 3 and the # key.
7 = Fuse Fail [eg. 1234 + 3 + #].
8 = AC Fail
Press and Hold Button 2 2. Press 1 followed by the # key.
To Determine Fault
2 RF Low Battery
Displays Zones (1 – 8) that 3. Enter the Call Forward On sequence.
registers RF Low Battery
Press and Hold Button 3 4. Press the # key to exit.
To Determine Fault
3 Zone Tamper
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 4 Telco Disarm Sequence (Call Forward On)
To Determine Fault 1. Enter your Installer Code or Master Code
4 Sensor Watch
Displays Zones (1 – 8) that followed by 3 and the # key.
registers Zone Tamper
[eg. 1234 + 3 + #].
Press and Hold Button 5
To Determine Fault
5 RF Sensor Watch
Displays Zones (1 – 8) that
2. Press 2 followed by the # key.
registers Zone Tamper
Press and Hold Button 6 3. Enter the Call Forward Off sequence.
To Determine Fault
6 Communication Fail 4. Press the # key to exit.
1 = Receiver 1 Fail (Dialler)
2 = Receiver 2 Fail (Dialler)
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
8 Solution Ultima 862 Quick Reference Guide
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 9
Location 177
Dialler Options 1 1 = Dialler Reporting Functions Allowed
2 = Remote Arming Via Telephone Allowed
4 = Answering Machine Bypass Only When Armed 9
8 = Use Bell 103 For FSK Format (Disabled = CCITT V21)
Location 178
Dialler Options 2 1 = Open/Close Reports Only If Previous Alarm
2 = Open/Close Reports For STAY Mode 1 and STAY Mode 2
4 = Delay Siren Until Transmission Complete
8 = Extend Handshake Wait Time From 30 To 55 Seconds
0
Location 179
Dialler Options 3 1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Lockout Telephone Line Fail Alarm (V1.03+)
4 = Change Decadic Dialling To 60/40
8 = Reserved
0
Location 179
Dialler Options 3 (V1.04+) 1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Lockout Telephone Line Fail Alarm (V1.03+)
4 = Change Decadic Dialling To 60/40 2
8 = External Modem Module (CC811) Required For FSK (V1.09+)
Location 180
Alarm Link Options 1 = Upload/Download Allowed
2 = Call Back Phone Number Required For Upload/Download
4 = Exit Upload/Download Connection On Alarm
8 = External Modem Module (CC811) Required For Alarm Link 3
Location 181 - 184
Installer Code
1 2 3 4
Location 185 - 264
User Codes
Location 185 - 188 189 Location 190 - 193 194 Location 195 - 198 199
User #01 User #02 User #03
2 5 8 0 10 15 15 15 15 2 15 15 15 15 2
Authority Authority Authority
Level Level Level
Location 200 - 203 204 Location 205 - 208 209 Location 210 - 213 214
User #04 User #05 User #06
15 15 15 15 2 15 15 15 15 2 15 15 15 15 2
Authority Authority Authority
Level Level Level
Location 215 - 218 219 Location 220 - 223 224 Location 225 - 228 229
User #07 User #08 RF User #09
15 15 15 15 2 0 15 15 15 3 15 15 15 15 2
Authority Authority Authority
Level Level Level
Location 230 - 233 234 Location 235 - 238 239 Location 240 - 243 244
RF User #10 RF User #11 RF User #12
15 15 15 15 2 15 15 15 15 2 15 15 15 15 2
Authority Authority Authority
Level Level Level
Location 245 - 248 249 Location 250 - 253 254 Location 255 - 258 259
RF User #13 RF User #14 RF User #15
15 15 15 15 2 15 15 15 15 2 15 15 15 15 2
Authority Authority Authority
Level Level Level
Authority
Description
Level
0 Arm/Disarm
1 Arm Only
2 Arm/Disarm + Open/Close Reports
3 Arm Only + Close Reports
4 Arm/Disarm + Code Required To Isolate
6 Arm/Disarm + Open/Close Reports + Code Required To Isolate
8 Master Code + Arm/Disarm
10 Master Code + Arm/Disarm + Open/Close Reports
12 Master Code + Arm/Disarm + Code Required To Isolate
14 Master Code + Arm/Disarm + Code Required To Isolate + Open/Close Reports
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
10 Solution Ultima 862 Quick Reference Guide
Location 265
Day Alarm Zones 1 = Zone 1 4 = Zone 3
2 = Zone 2 8 = Zone 4 0
Location 266
EOL Resistor Value
0 = No EOL 6 = 4K7 12 = Reserved
1 = 1K 7 = 5K6 13 = Reserved
2 = 1K5 8 = 6K8 14 = Split EOL (3K3/6K8 With Tamper (1K)
3 = 2K2 9 = 10K 15 = Split EOL (3K3/6K8)
4 = 3K3 10 = 12K
5 = 3K9 11 = 22K
15
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 11
Zone Types
Option 20ms Loop Response Time Option 150 ms Loop Response Time
0 0.5 Seconds 8 20 Seconds
1 1 Second 9 30 Seconds
2 2 Seconds 10 40 Seconds
3 3 Seconds 11 50 Seconds
4 4 Seconds 12 60 Seconds
5 5 Seconds 13 90 Seconds
6 10 Seconds 14 120 Seconds
7 15 Seconds 15 200 Seconds
Option Description
0 Latching Arm and Disarm In AWAY Mode
1 Latching Arm In AWAY Mode
2 Latching Disarm From AWAY Mode Or STAY Mode
4 Latching Arm and Disarm In STAY Mode
5 Latching Arm In STAY Mode
6 Latching Disarm From STAY Mode
8 Momentary Arm and Disarm In AWAY Mode
9 Momentary Arm In AWAY Mode
10 Momentary Disarm From AWAY Mode Or STAY Mode
12 Momentary Arm and Disarm In STAY Mode
13 Momentary Arm In STAY Mode
14 Momentary Disarm From STAY Mode
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
12 Solution Ultima 862 Quick Reference Guide
Location 323
Swinger Shutdown Count For Siren 0 = Unlimited / 1 - 15 = Number Of Times Siren Operate Till Lockout 3
Location 324
Swinger Shutdown Count For Dialler 0 = Unlimited / 1 - 15 = Number Of Times Dialler Operate Till Lockout 6
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 13
Location 348
Codepad Duress Report 6
Location 349 - 350
Codepad Panic Report Location 349 = Tens Digit
Location 350 = Units Digit 7 15
Location 351 - 352
Codepad Fire Report Location 351 = Tens Digit
Location 352 = Units Digit 7 14
Location 353 - 354
Codepad Medical Report Location 353 = Tens Digit
Location 354 = Units Digit 7 13
Location 355
Codepad Reporting Options 0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
8 = Report To Receiver 2 Only If Receiver 1 Fails 1
Location 356 - 357
System Status - Fuse Fail Report Location 356 = Tens Digit
Location 357 = Units Digit 10 3
Location 358 - 359
System Status - Fuse Fail Restore Report Location 358 = Tens Digit
Location 359 = Units Digit 10 8
Location 360 - 361
System Status - AC Fail Report Location 360 = Tens Digit
10 2
Location 361 = Units Digit
Location 362 - 363
System Status - AC Fail Restore Report Location 362 = Tens Digit
10 7
Location 363 = Units Digit
Location 364 - 365
System Status - Low Battery Report Location 364 = Tens Digit
10 1
Location 365 = Units Digit
Location 366 - 367
System Status - Low Battery Location 366 = Tens Digit
10 6
Restore Report Location 367 = Units Digit
Location 368 - 370
Location 368 = Code Retry Limit (0 = Unlimited) 368 369 370
System Status - Access Denied (Code Retry)
Location 369 = Tens Digit 6 7 12
Location 370 = Units Digit
Location 371
System Status Reporting Options 0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
8 = Report To Receiver 2 Only If Receiver 1 Fails 1
Location 372 - 378
Test Report Time (Automatic) Location 372 = Hour Of Day (Tens Digit)
Location 373 = Hour Of Day (Units Digit)
Location 374 = Minute Of Day (Tens Digit) 372 373 374 375 376 377 378
Location 375 = Minute Of Day (Units Digit)
Location 376 = Test Report (Tens Digit) 0 0 0 0 7 1 0
Location 377 = Test Report (Units Digit) H H M M Tens/Units Interval
Location 378 = Repeat Interval In Days Report Code
Location 379
Test Reporting Dialler Options 0 = No Codepad Alarm Reports Allowed
1 = Report To Receiver 1
2 = Report To Receiver 2
4 = Report To Both Receiver 1 & Receiver 2
1
8 = Report To Receiver 2 Only If Receiver 1 Fails
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
14 Solution Ultima 862 Quick Reference Guide
Location 392 393 394 395 396 397 Location 398 399 400 401 402 403
Strobe Output Relay Output
2 0 6 4 0 8 1 15 1 0 0 0
Default = Strobe Event Polarity Time Time Base Default = Sirens Event Polarity Time Time Base
(Reset After 8 Hrs) Code Base Multiplier Running Code Base Multiplier
Event Codes
Event Event
Description Description
Code Code
0 0 BOSCHSAT – Satellite Siren (Output 1 Only) 3 1 Dialler Disabled
0 1 System Armed 3 2 Dialler Active (On-Line)
0 2 System Disarmed 3 3 Ring Detect
0 3 Armed In STAY Mode 3 4 Codepad Panic (Multibreak) V1.05+
0 4 Armed In AWAY 3 5 Mimic Zone 1
0 5 Pre-Arming Alert 3 6 Mimic Zone 2
0 6 Exit Warning (All Zones Sealed) + Entry Warning 3 7 Mimic Zone 3
0 7 Exit Warning 3 8 Mimic Zone 4
0 8 Exit Warning Finished 3 9 Mimic Zone 5
0 9 Kiss-Off After End Of Exit Time 3 10 Mimic Zone 6
0 10 Reserved 3 11 Mimic Zone 7
0 11 Entry Warning 3 12 Mimic Zone 8
0 12 Entry Warning + Day Alarm Resetting 3 13 Reserved
0 13 Exit Warning + Entry Warning + Day Alarm Resetting 3 14 Reserved
0 14 Day Alarm Resetting 3 15 Reserved
0 15 Day Alarm Latching 4 0 Reserved
1 0 Day Alarm Enabled 4 1 Reserved
1 1 Telephone Line Fail 4 2 Reserved
1 2 Kiss-Off Received 4 3 Reserved
1 3 Fuse Fail 4 4 Reserved
1 4 AC Fail 4 5 Chime
1 5 Low Battery 4 6 Zone Not Sealed
1 6 Horn Speaker Fail 4 7 Zone Not Sealed After Exit Time
1 7 Sensor Watch Alarm 4 8 Reserved
1 8 Codepad Medical Alarm 4 9 AC Mains Cycle (60 Hz Or 50 Hz)
1 9 Codepad Fire Alarm 4 10 Area 1 - Zone Unsealed (Solution 880 Only)
1 10 Codepad Panic Alarm 4 11 Area 2 – Zone Unsealed (Solution 880 Only)
1 11 Codepad Duress Alarm 4 12 Reserved
1 12 Access Denied (Code Retries) 4 13 Reserved
1 13 Reserved 4 14 Reserved
1 14 Horn Speaker (Output 1 Only) 4 15 Reserved
1 15 Sirens Running 5 0 Reserved
2 0 Strobe 5 1 Reserved
2 1 Silent Alarm 5 2 Area 1 In Alarm (Solution 880 Only)
2 2 Alarm In STAY Mode 5 3 Area 2 In Alarm (Solution 880 Only)
2 3 Alarm In AWAY Mode 5 4 Reserved
2 4 System Fault 5 5 Reserved
2 5 Fire Alarm (Resetting) 5 6 Area 1 Armed (Solution 880 Only)
2 6 Fire Alarm (Latching) 5 7 Area 2 Armed (Solution 880 Only)
2 7 Fire Alarm (Verification) 5 8 Reserved
2 8 Remote Control 1 5 9 Reserved
2 9 Remote Control 2 5 10 Area 1 Disarmed (Solution 880 Only)
2 10 Remote Control 3 5 11 Area 2 Disarmed (Solution 880 Only)
2 11 Radio Control Output 1 5 12 Reserved
2 12 Radio Control Output 2 5 13 Reserved
2 13 Radio Control Output 1 - Not In AWAY Mode 5 14 Any Areas Armed (Solution 880 Only)
2 14 Radio Control Output 2 - Not In AWAY Mode 5 15 Any Areas Disarmed (Solution 880 Only)
2 15 Communications Fail After 3 Attempts 6 0 Area 1 Codepad Data Terminal (Solution 880 Only)
3 0 Communications Fail 6 1 Area 2 Codepad Data Terminal (Solution 880 Only)
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 15
Polarity (Modes)
Time Base
Choose one of the options in the table below for the time base.
Option Description
1 200 ms
2 1 Second
3 1 Minute
4 1 Hour
Pulsing Mode
When you program the output polarity as pulsing, the time base becomes the ‘ON’ time and the multiplier
becomes the ‘OFF’ time. The ‘OFF’ time is the time base x the multiplier (eg. If you want the output to pulse
one (1) second ‘ON’ and five (5) seconds ‘OFF’, you would program time base as one (1) and the multiplier as
five (5)).
Location 434
Kiss-Off Wait Time Location 434 = Increments Of 500 ms (500 ms - 8 Seconds) 3
Location 435
Speaker Beep Volume Location 435 = (0 = No Beeps / 15 = Loudest Beeps) 13
Location 436
System Options 1 1 = BOSCH Smart Lockout Allowed
2 = Horn Speaker Monitor
4 = Strobe Indication For Radio Arm/Disarm
8 = Assign Button 4 On Transmitter To Operate STAY Mode 1
1
Location 437
System Options 2 1 = Codepad Panic To Be Silent
2 = Codepad Fire To Be Silent
4 = Codepad Medical To Be Silent
8 = Access Denied (Code Retries) To Be Silent
0
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 17
Location 438
System Options 3 1 = AC Fail After 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
8
Location 439
System Options 4 1 = Panel To Power Up Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Radio Keyswitch Interface, Night Arm Station Or RE005 Installed
0
Location 440
Consumer Options 1 1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
0
Location 441
Consumer Options 2 1 = Codepad Display Extinguish After 60 Seconds
2 = Single Button Arming Allowed (AWAY/STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
2
Location 442
Consumer Options 3 1 = Codepad Fault Beeps Allowed
2 = Use Digit 3 For Codepad Duress Alarm (Instead Of Digit 9)
4 = Alarms Activate Sirens and Strobe Outputs In STAY Mode 1 & 2
8 = Zone Tamper Alarms To Be Silent
5
Location 443
Radio Input Options 1 = DS 304Mhz RF Receiver (RF3212)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
0
Location 478 - 525
Domestic Telephone Numbers
Location 526
Reserved
0
Location 527
RF Options 1 = Sound Siren On RF Receiver Fail
2 = Sound Siren On RF Receiver Tamper / Jamming
4 = Unseal Zone That Fails Supervision (If Supervision Enabled)
8 = RF Jamming Monitoring Allowed
0
Location 528 - 535
RF Device Mapping Location 528 = Map RF Device 1 To Zone (1 To 8)
For Devices 1 – 8 Location 529 = Map RF Device 2 To Zone (1 To 8)
Location 530 = Map RF Device 3 To Zone (1 To 8)
Location 531 = Map RF Device 4 To Zone (1 To 8)
Location 532 = Map RF Device 5 To Zone (1 To 8) 528 529 530 531 532 533 534 535
Location 533 = Map RF Device 6 To Zone (1 To 8)
Location 534 = Map RF Device 7 To Zone (1 To 8) 1 2 3 4 5 6 7 8
Location 535 = Map RF Device 8 To Zone (1 To 8) D1 D2 D3 D4 D5 D6 D7 D8
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
18 Solution Ultima 862 Quick Reference Guide
Location 900
Default Options 0 = Defaulting System Allowed / 15 = Defaulting System Disabled 0
Location 901 - 904
System Time
Location 901 = Hour Of The Day (Tens Digit) 901 902 903 904
Location 902 = Hour Of The Day (Units Digit)
Location 903 = Minute Of The Day (Tens Digit) 0 0 : 0 0
Location 904 = Minute Of The Day (Units Digit) H H M M
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 19
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
20 Solution Ultima 862 Quick Reference Guide
Connections For Split EOL Resistors For Six Burglary Zones and Two 24 Hr Zones
Figure 4: Split EOL Wiring Diagram (Location 266 = 15) Figure 5: Split EOL Wiring Diagram With Tamper
(Location 266 = 14)
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited
Solution Ultima 862 Quick Reference Guide 21
Wiring Diagram
Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE.D
22 Solution Ultima 862 Quick Reference Guide
Component Overlay
SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited