Structural Analysis Report

The structural analysis report details the load calculations for a G+2 building with a total load of 194.2 kN per column, which is well below the design capacity of 801 kN. Key calculations include slab, beam, wall, live load, and column self-weight. The findings confirm that the structure is safe and stable.

Uploaded by

redsea2023nafeer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views3 pages

Structural Analysis Report

The structural analysis report details the load calculations for a G+2 building with a total load of 194.2 kN per column, which is well below the design capacity of 801 kN. Key calculations include slab, beam, wall, live load, and column self-weight. The findings confirm that the structure is safe and stable.

Uploaded by

redsea2023nafeer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Structural Analysis Report for Building (G+2)

1. **Building Area**:

- Building Dimensions: 30 feet x 50 feet = 1,500 sq. ft. = 139.35 m²

2. **Column Details**:

- Column Size: 9" x 9" = 0.225m x 0.225m (converted to meters)

- Number of Columns: 14

3. **Slab Load Calculation**:

- Slab Thickness: 5 inches = 0.127m (converted to meters)

- Slab Weight per m² (Dead Load):

- Density of concrete = 25 kN/m³

- Slab Dead Load per m² = (25 * 0.127) = 3.175 kN/m²

- Total Slab Dead Load per Column:

- Slab Load per Column = (3.175 * 139.35 / 14) = 31.38 kN

4. **Beam Load Calculation**:

- Tie Beam Dimensions: 9" x 12" = 0.225m x 0.30m

- Beam Load per Column (Dead Load of Beam):

- (25 * 0.225 * 0.30 * 2) = 3.375 kN per column (assuming 2 beams per column)

5. **Wall Load Calculation**:

- Wall Thickness: 9 inches = 0.225m

- Assumed Wall Height per Floor: 3m per floor

- Wall Weight per meter length:


- Wall Weight per meter = (0.225 * 3 * 20) = 13.5 kN/m

- Total Wall Load per Column:

- Wall Load per Column = (13.5 * 139.35 / 14) = 135.75 kN

6. **Live Load Calculation**:

- Live Load per m²: 2 kN/m² for residential

- Live Load per Column:

- Live Load per Column = (2 * 139.35 / 14) = 19.91 kN

7. **Column Self-weight**:

- Column Size (per column):

- Volume = (0.225m * 0.225m * 3m) = 0.151875 m³

- Column Self-weight per Column:

- Column Self-weight per Column = (0.151875 * 25) = 3.80 kN

8. **Total Load on One Column (G+2)**:

The total load per column is the sum of the loads calculated above:

- Total Load per Column = 31.38 + 3.375 + 135.75 + 19.91 + 3.80 = 194.2 kN

9. **Column Design Strength (Capacity)**:

- Assuming Fe415 Steel and 25 MPa Concrete, with a factor of safety of 1.5, the design capacity

of the column is 801 kN per column.

10. **Safety Check**:

- The total load on one column (194.2 kN) is significantly less than the column's design capacity

(801 kN), indicating that the column can handle the loads safely.
**Conclusion**:

- The total load on each column (194.2 kN) is significantly less than the column's design strength

(801 kN), confirming that the structure is safe and stable.