The Brave Slim door intercom user guide provides detailed information on the features, installation, and programming of the intercom system, which includes various models such as Brave Slim - C, C/C, and LC. Key features include surface installation, IP 44 protection, integrated analog camera options, and programmable settings via phone or USB. The guide also outlines assembly instructions, connection requirements, and technical parameters for optimal use.

Uploaded by

s.navarro.ceyco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views56 pages

Brave Manual v12

The Brave Slim door intercom user guide provides detailed information on the features, installation, and programming of the intercom system, which includes various models such as Brave Slim - C, C/C, and LC. Key features include surface installation, IP 44 protection, integrated analog camera options, and programmable settings via phone or USB. The guide also outlines assembly instructions, connection requirements, and technical parameters for optimal use.

Uploaded by

s.navarro.ceyco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 56

Brave – Door Intercom

Brave Slim - C
Brave Slim - LC
Brave Slim - C/C

User guide
Version 1.2
Dear customer
Congratulation to your purchase of “BRAVE SLIM door intercom”. The
BRAVE Slim door intercom is designed as universal project to be suitable for
different installation on the field and brings more features and possibilities.
This manual is designed for Urmet 1129 panel in 4 models with 1 or 2
buttons:
Brave Slim - C - Comfort model
Brave Slim - C/C - Comfort model with analog camera
Brave Slim - LC - Low cost model

Basic features of BRAVE door intercoms


• SLIM solution – surface installation only
• IP 44 casing protection
• LED cards lighting
• Integrated analog color camera (C/C, LC/C)
• 1 (2*) relay with 8 different operational modes
• possibility to use electrical lock PSU for feeding the unit (C)
• elektronical loudness settings ( without neccessity open the unit)
• adjustable tones detection for REDIAL or Hanging Up
• integrated RTC ( realtimeclock) circuit – automatical DAY/NIGHT
switching (C)
• programming by phone DTMF or by USB cable from PC**
• 24 digits length of number including * # Flash and Pause
(C/C, LC/C) – models only
* Comfort version only
** USB cabel is an option

Version of manual V1.2 24.2.2012


Alphatech Technologies s.r.o.
www.alphatechtechnologies.cz
Content
1 BASIC DESCRIPTION ......................................................................................... 6
1.1 FEATURES ........................................................................................................ 6
1.2 TERMINOLOGY ................................................................................................. 7
1.3 DIFFERENT MODELS OF SLIM BRAVE DOOR INTERCOM ................................... 8
1.4 MODELS OF BRAVE DOOR INTERCOM ............................................................... 8
1.5 PCB SCHEMATICS ............................................................................................ 9
2 INSTALLATION ................................................................................................. 12
2.1 ASSEMBLY ..................................................................................................... 12
2.1.1 Assembly of Brave Slim front panel .......................................................... 12
2.1.2 Assembly of cards backlighting................................................................. 13
2.1.3 Wall mounting of Brave Slim .................................................................... 13
2.1.4 Replacing of cards backlighting after wall mounting ............................... 14
2.1.5 Cards exchange (name cards)................................................................... 14
2.2 CONNECTION ................................................................................................. 15
2.3 CAMERA ( /C VERSION ONLY) ........................................................................ 18
2.4 ACCSSESORIES ............................................................................................... 19
2.4.1 Weather hood 19
2.4.2 TimeRelay 19
2.4.3 DistyBox 19
2.4.4 Power supply 12V ..................................................................................... 20
2.4.5 Programming cable USB .......................................................................... 20
2.4.6 BlackBox 20
3 DOOR INTERCOM SERVICE ......................................................................... 21
3.1 SIGNALLING OVERVIEW ................................................................................. 21
3.2 VISITOR AT THE DOOR .................................................................................... 22
3.3 PERSON INSIDE BUILDING ............................................................................... 24
3.3.1 Outgoing call 24
3.3.2 Incoming call 25
4 PARAMETRES PROGRAMMING .................................................................. 26
4.1 PROGRAMMING BY PHONE ............................................................................. 26
4.1.1 Programming enter ................................................................................... 26
4.1.2 Parametres programming ......................................................................... 26
4.2 PC PROGRAMMING – BRAVESET PROGRAMM ................................................ 27
5 DESCRIPRION OF PROGRAMMABLE PARAMETRES ............................ 28
5.1 DIRECT NUMBERS DIAL – MEMORIES .............................................................. 28
5.2 RELAY(S) ....................................................................................................... 29
5.3 BASIC PARAMETRES ....................................................................................... 33
5.4 TIME PARAMETRES......................................................................................... 35
5.5 SYSTEM PARAMETRES .................................................................................... 38
5.6 HANDSFREE PARAMETRES SETTING ............................................................... 40
5.7 TIME PROGRAMM – AUTOMATIC DAY/NIGHT SWITCHING (C) ..................... 43
5.8 DEFAULT SETTTING AND ERASING ................................................................. 45
5.9 PROGRAMMING TERMINATION ....................................................................... 45
5.10 PARAMETRES OVERVIEW ............................................................................... 46
6 TECHNICAL PARAMETRES .......................................................................... 50
6.1 ELEKTRICAL PARAMETRES ............................................................................. 50
6.2 MECHANICAL DIMENSIONS ............................................................................ 50
7 TABLE FOR EASY PROGRAMMING ............................................................ 51

BRAVE – user guide 5


1 BASIC DESCRIPTION
1.1 Features
➢ Voice communication is powered from telephone line only
➢ Tone (DTMF) and pulse dial
➢ Two 24digit numbers with each button (including *, #, Flash and Pause)
➢ DAY/NIGHT switching by DTMF code or automatically by integrated
real time clocks - RTC, weekly schedule (C model)
➢ Possibility of the call extension by * or # choice
➢ Possibility to connect 1 or 2 (only C) independent locks for door
opening
➢ 8 different relays modes (for example: additional ring, progressive
opening)
➢ Two codes for hanging up the unit by telephone
➢ Two codes for door opening by telephone for 1 pulse and two codes for
2 pulses
➢ 3 x 6 codes for each relay (code by buttons at doors)
➢ Possible switched on hang up by press the same push button
➢ Possible switched on mode "Baby Call"
➢ Possible switched on suppress receive DTMF by microphone
➢ Possible switched on accoustic tick to the conversation for speech
recognition
➢ Possible switched on accoustic signalization of close the relay
➢ Adjustable number of rings before pick up an incoming call
➢ Adjustable parameters of tone dial, length of Flash and Pause
➢ Adjustable parametres of acoustical signalization
➢ Adjustable parametres of tones detector
➢ Elektronical loudness settings ( without neccessity open the unit)
➢ Integrated analog colour camera with permanent or automatical
operation /C
➢ Automatical camera lighting infra LED /C
➢ Possibility of powering by external PSU 12V (Siemens) /C (C)
➢ Easy settings of HW by DIP switch
➢ Factory settings (default) in different levels
➢ Programming by phone DTMF or by USB cable from PC
➢ Integrated heating for PCB
➢ Permanent cards lighting, switchable
➢ Ground output for better protection against static electricity

(C) – comfort model only (Comfort)


/C - model with camera only

6 BRAVE – user guide


1.2 Terminology
Telephone line analog (2 wires) is way of connection to public network
(PSTN line) or connection to PABX – telephone exchange at
place of installation ( extension line)
Line picking up begin of call – same like OFF HOOK by handset
Line hanging up end of call – same like ON HOOK by handset
Dial DTMF - tone dial. It is dial by 2 tones combination (dial also
special character * and #. Use Flash loop interruption)
Pulse – dial by loop interruption (dial numbers only)
Incoming call connection between intercom and phone has been done by
dial from phone.The intercom picks up the call after
preprogrammed number of rings. After picking up and
password inserting you can programm the unit by phone.
Outgoing call connection between intercom and phone has been done by
dial from intercom, for example : by button pressing
Call establishing it is stage when call is picked up by called party. This stage
is not signalled at analog line. It just stop ringing tone and
call starts. It is difficult identify just this moment.
El.lock code function for relay closing by dial digits combination from
intercom buttons
External code Digits combination dial from intercom buttons for relay
activation. External = dial by intercom buttons – out of
building ( at place of door intercom installation)
Internal code Digits combination dial from phone for relay activation
(DTMF). Internal = dial by phone – inside building ( phone
connected to other PBX extension)

The manufacturer continuously improves the product firmware. The


technology used allows you to upload to Brave the latest version of the
firmware any time using a standard computer with BraveSet and USB
cable. The latest version of the firmware is available at
http://www.alphatechtechnologies.cz

BRAVE – user guide 7


1.3 Different Models of Slim Brave door intercom
Brave door intercoms is designed as new generation of door intercom
units reflects all experiences collected during last 10 years of succesfull sales of
door enry solutions. Features and parametres are different for different models
of intercom to provide best balance between price and usage value.
In this manual you will meet features and parametres marked by (C) which are
specific for Brave Slim (Comfort) model only and features and parametres
marked (M) which are planned for modular model (in Slim solution are not
provided due mechanical solution)
Labelling of availability function :
Model LC (low cost) has all features except particularly marked
Model /C is version equiped by full colour analog camera
Model C (comfort) has special features marked by (C)
Model M (modular) has marked (M) – in mechanical Slim solution is not
produced! And it is mentioned in programming tables only which are same for all
models.

1.4 Models of Brave door intercom


SLIM models of Brave LC/C includes appropriate mother board with all
connectable elements.

Brave Slim - 01C Brave Slim - 01C/C Brave Slim – 02C Brave Slim – 2C/C
Brave Slim - 01LC Brave Slim – 02LC

Models LC and C are different up mother board components. In model (LC) is


missing:
• Second relay
• RTC real time clocks for automatic DAY/NIGHT switching
Models with camera /C have added:
• Possibility of external powering (usable for relay modes 7 and 8)
• automatical / permanent lighting for camera (infra)
• switch off cards lighting
• disconnectable internal impedance for camera cable ending 75ohm

8 BRAVE – user guide


1.5 PCB Schematics
All functional and connectional elements are marked by red rounded
number at bellow picture. Explanation follow on next page.

Pict. 1 Brave Slim mother board


(1) + (3) + (7) + (11) - version /C only
relay 2 version (C) only
BRAVE – user guide 9
1. Camera lighting - infra LED. It lights up space before camera when is active.
It is possible switch off (via. item 7) – version for camera only /C
2. Connector to PC connection via USB cable
3. Analog colour camera – version with camera /C only
4. Speaker connection
5. Microphone connection (caution on polarity)
6. DIP switch in all models:
1 = Service, usage – when programming
password is forgotton. Incoming call is
going directly to programming mode
where you can set new password.
2 = Heating – switch ON integrated heating of mother board to increase resistance
against condensation water during changes of temperature
7. DIP switch position in versions (C) and /C:
3 = external power supply
4 = external power supply – switching 3 and 4 simultaneously. The powering is
used from screw 12V (11) due following reasons:
- using relay mode 7 or 8 – tpermanent switching ON/OFF is possible only
with external power supply. Dont forget setup parametr 64.
- Connection of door intercom to certain type of PBX which has problems
with current consumption on its extensions during start (Siemens).
5 = Camera lighting up (switch ON/OFF lighting of space before camera via infra
LED)
6 = Cards lighting (switch ON/OFF Leds backlighting for cards beside button)
7 = Activate permanent camera operation. In default camera is active only when
door intercom is active.
8 = Allows connect 75ohm to camera output - impedance
8. Analog telephone line (not depends on polarity)
9. Grounding – connection to ground of static electricity protection – protects
electronic of door intercom as same as PBX
10. Relays are galvanically isolated - max. 48V, max. 1,5A
model (C) has 2 relays
model (LC) has 1 relay only
11. Camera output - PAL video 1V / 75ohm. For distance longer than 25m we
recommend coax cable. For other installation UTP cable is also available. /C
model only
12. 12V power supply: - relays control
- mother board heating
- cards backlighting
- camera powering and infra LED camera lighting up
- external powering of unit (DIP 3 and 4)
The power supply might be AC as same as DC, not depends on polarity,
max consumption 250mA from 12V.
The power supply might be used also for electrical lock powering. Then we
recommend power supply 12V/1A.

10 BRAVE – user guide


You can also use 24V DC power supply. It is useful mainly at installations
where power supply is already installed and it is used for sliding doors,
RFID, etc.. The heating has control element to restrict power.
The remaining components are designed for voltage up 24V DC!!!
It not depends on polarity.

BRAVE – user guide 11


2 Installation
2.1 Assembly
2.1.1 Assembly of Brave Slim front panel

12 BRAVE – user guide


2.1.2 Assembly of cards backlighting

2.1.3 Wall mounting of Brave Slim


Make the mounting by attached pack with screws and plug (drill 5mm).

BRAVE – user guide 13


2.1.4 Replacing of cards backlighting after wall mounting

2.1.5 Cards exchange (name cards)

Every button has own card ( label) holded by plastic flag ( via picture).
You can print out paper labels from special Excel file.

14 BRAVE – user guide


2.2 Connection
The basic functionality of intercom (voice communication) needs
connection of telephone line only - LINE (8) on .Pict. 1 Brave Slim. The line is
connected by 2 wires (a,b) and in stand by has usually voltage 24V - 60V, short
circuit current 20mA - 60mA. When line is OFF HOOK the line voltage is 7V -
10V.
Line connection Brave Slim intercom announce by sound signal
(Reset) ♫ (capture 3.1 page.21) when is disconnected from line certain time.
Brave Slim is analog intercom designed for connection to analog line( PSTN line
or PBX analog extension) it means line where works ordinary analog phone. It
works regardless to line polarity and in range mentioned in technical parametres
(capture 6).
Paralel connection – we not recommend! Paralell connection with
other analog phone or other door intercom is not recommended! We also not
recommend use special devices switching the line ( inteligent couplers,
adapters, etc..).
When model of Brave Slim is with camera /C then on screw CAM (11)
on Pict. 1. connect cable for video transmission. Up to 25m you can use one
free pair of UTP cable. For longer distances you have to use coax cable Pict. 1.
Camera mode you setup by DIP switch (capture 1.5) and camera is either
activated automatically (when intercom is active) or is permanently ON (DIP 7).
Camera lighting up by infra LED is either active with camera (DIP 5) or you can
permanently switch OFF. Due DIP 8 you can paralelly connect to video output
impedance 75ohm
12V power supply (12) on Pict. 1 must be connected for mother board
heating, cards backlighting, camera powering inludes infra LEDs and for relays
control. The power supply might be AC and also DC, not depends on polarity.
From 12V is max consumption 250mA. Power supply might be used also for
electrical lock powering. Then we recommend power supply 12V/1A. You can
also use 24V DC power supply. It is useful mainly at installations where power
supply is already installed and it is used for sliding doors, RFID, etc..
You can use only 24DC power supply not AC!!! Not depends on polarity.
Relays (10) on Pict. 1 have many possibilities in practise usage. The
examples (drawings) are mentioned on Pict. 2. 12V power supply must be
connected for correct operation. The intercom unit has galvanically isolated all
important parts. Telephone line is isolated from power supply and relays
contacts are also galvanically isolated from other intercom electronic parts.
In any case must not be activated directly main voltage 120V or
230V !!! When you need control main devices please use contactors ( power
relays) as it is on Pict. 2 example (6) .

BRAVE – user guide 15


Relays connection examples are mentiond on following page. It is not all of
them but give you an idea how should be connected individual circuits (red rings
with numbers = example numbers).
1. Basic connection - 2 elektrical locks and possibility independently control
two doors. (relay mode 1 and 2 m=1) or progressive door opening (relay
mode 2 m=5 - version (C) only.
2. Two power supply – possibility to use independently two power supply One
for Brave Slim and second for electrical locks. Second electrical lock is
connected inversaly (fire emergency exit).
3. Combination of doors with electrical lock and sliding gate at fencing.
4. Extending of previous example (3) about second doors with progressive
opening (this feature is setup in TimeRelay - optional modul)
5. Combination of electrical lock and additional ring. Relay of additional ring
might be in mode m=4 (from each button is activated for preprogrammed
time) or in mode m=6 (it is activated from one presetup button for
preprogrammed time)
6. Lighting activation m=3 (for example: way to building ) and control of for
example: heating up DAY/NIGHT mode m=8 ( (C) version only - RTC
circuit). External power supply required (DIP 3 and 4) /C version only.
Further is neccessary use contactor (Brave Slim must not activate 230V!).

16 BRAVE – user guide


Pict. 2 Examples of relay connection
BRAVE – user guide 17
2.3 Camera ( /C version only)
Technical parametres:
- videonorm: PAL-CCIR
- sensor: CMOS 1/3''
- picture area: 5,78x4,19mm
- resolution: 628x582pixel 380 rows
- video output: 1V p-p/75 ohm
- automatic profit control: 18dB
- minimal lighting: 3LUX
- automatic lens shutter: 1/60-1/15000sekund
- camera view: 50st.

- zoom: manually

18 BRAVE – user guide


2.4 Accssesories
2.4.1 Weather hood
It increases intercom
protection during raining. It is
fixed by adhesive labels from
sides.

2.4.2 TimeRelay
Time relay allows expansion of relays
functionality.

2.4.3 DistyBox
This optional modul is plastic box allows
you to connect analog unit (phone,
intercom) into wireless system DECT –
GAP (for example Siemens line GigaSet,
TopCom line Butler etc.). DistyBox is
suitable for intercom connection when are
cables not available. You just registrate
intercom as handset to DECT base
station. All features of intercom are kept.
Important: DECT base station must support
DTMF transmission between each handsets
(relay activation feature).

BRAVE – user guide 19


2.4.4 Power supply 12V
As standard we provide for Brave Slim
intercom AC power supply 12V/1A . It is
not part of unit packaging. It must be
ordered individualy..

2.4.5 Programming cable USB


USB cable is not part of packaging. It
must be ordered individualy.

2.4.6 BlackBox
BlackBox is DTMF modem useful for remote programming from PC. Via
BraveSet programm you can remotely setup
all parametres of Brave Slim intercom.

20 BRAVE – user guide


3 Door intercom service
Functionality of Brave Slim door inercom is adjustable by parametres
settings (via. Programming parametres capture page 26).

3.1 Signalling overview


The Brave Slim door intercom signalling acoustically stages which are
happening during operation. Samples of acoustical sounds you can play in
BraveSet ( PC programm).
Stage Tones Tone frequency
Line pick up ( OFF HOOK) type 1 –▄■▄■▀– 980-1333-1650

Line hang up ( ON HOOK) type1 –▀■▄■▄– 1650-1333-980

Line pick up ( OFF HOOK) type 2 –▄■▀– 800-1067-1200-1333

Line hang up ( ON HOOK) type2 –▀■▄– 1333-1200-1067-800

Command confirmation by phone ––█–– 800


Alerting (knocking) into call ─┴─┴─
Call ending alert –■–■–■– 1333
Relay activation signal ─▒▒▒▒▒▒─ Modulovaný
Programming enter by phone –▄■▀– 980-1067-1180

Programming by phone ––▓–▓––––– Modulovaný


Parametr confirmation ––█–– 800
Programming enter by PC –▄■▀– 980-1067-1180

Line connection (Reset) –■–▄–■– 1850-1067-1850

Error (generally all incorrects) –■–■–■–■–■–■– 800


Memory empty (no number programmed) –▄■▄■▄■▄■– 1300-2100

During problems identification is very good when you know the tones. It
helps you monitor how door intercom works and where from comes the problem.
The signalling might be switch of in a few levels (parametres 61,62,63 and 65).

BRAVE – user guide 21


3.2 Visitor at the door
Door intercom buttons have signs (cards) like usual ring buttons. Visitor
find desired name (for example“Scott") and push it. The Brave intercom pick up
the line and "play" tone line pick up (when is not switch off by par.62) and dial
phone number saved under the button (parametr 1 or 2 up door intercom mode).
From Brave intercom speaker you hear ringing tone and phone of Mr. Scott is
ringing. As soon as Mr. Scott pick up ringing phone he can talk to visitor at the
door. When is electrical lock connected to Brave intercom then Mr. Scott can
open the door for visitor by dial DTMF code on his phone. When Mr. Scott hang
up the phone then Brave intercom hangs up as well after busy tone detection.
When call duration is longer then setup limit (parametr 52) the 10sec before
hang up Brave intercom sends alerting tone of call ending. Mr. Scott can dial *
or # up setting (parametr 42) to prolong the call about the time setup by
parametr 52.
Dialled number from Brave intercom is different up dial mode setup in the
unit by (parametr 47):
- Day/Night mode = when intercom is in DAY mode then number setup by
parametru 1 is dialled. When intercom is in NIGHT mode then always dial
number setup by parametr 2. Manual intercom modes switching is setup
by parametres 45,46. In version (C) you can switch DAY/NIGHT mode
automatically. Selection of dialled number saved under the button is control
by time up table (parametry 00-06).
- 2 groups numbers mode = first button push – always dial number setup
by parametr 1. When the same button is pushed or 10seconds after dial
busy tone is detected, or setup number of rings is out (parametr 56) the
door intercom dial number from second group setup by (parametr 2). When
you push the same button again you will dial again number from first group
etc.……(when after dial number from second group busy tone is detected
the repeating is finished)
When visitor push the button after line is picked up the door intercom
hangs up for time setup by parametr 54 and then picks up the line and dial new
number ( second push number). The number dialling is either by tone dial
(DTMF) or pulse dial up setting by parametr 41. There is one more option and it
is line hangs up by again pushing of same button (parametr 4*).
You can control relay(s) by door intercom buttons (code lock). When
visitor push buttons in order which match to setup code (parametr 32-34) and
time between each button press is not longer than setup by (parametr 53) then
door intercom picks up and activate appropriate relay (when relay setup is mode
m=1 or m=5) for time setup by parametr 37 eventually.39,30. Then hangs up.
The relay (up control code) can activate one pulse or two pulses with time
between each pulse setup by parametr 30 via. Tab. 1.

22 BRAVE – user guide


mode m = 1 (parametr 3111 and 3121)
Action Note Parametr Relay
Evaluation of correct 3211-3215
external code from According settings 3311-3315
buttons DAY/NIGHT 3411-3415
3221-3225
According settings 3321-3325
DAY/NIGHT 3421-3425
321*
According settings 331*
DAY/NIGHT 341*
322*
According settins 332*
DAY/NIGHT 342*
Internal code from 351
phone You can dial 1 or 2
numbers of code
2digits code is default 352
You can shorter it by
using * on first digit of 361
code during
programming
362

Mode m = 5 (parametr 3125)


Action Note Parametr Relay
Evaluation of correct 3211-3215
external code from According settings 3311-3315
buttons DAY/NIGHT 3411-3415
3221-3225
According settings 3321-3325
DAY/NIGHT 3421-3425
321*
According settings 331*
DAY/NIGHT 341*
322*
According settings 332*
DAY/NIGHT 342*
Internal code from 351
phone You can dial 1 or 2
numbers of code
2digits code is default 352
You can shorter it by
using * on first digit of 361
code during
programming
362

BRAVE – user guide 23


mode m = 4
Action Note Parametr Relay
Button push 3114
Any button different from
311* or 312*
3124

3114
Button setup by 311* or
312*
3124

Mode m = 6
Action Note Parametr Relay
Button push 3116 -
Any button different from
311* or 312*
3126 -

3116
Button setup by 311* or
312*
3126

Poznámka: t1 – time activation 1 of relay (parametr 371)


t2 – time between pulses 1 of relay (parametr 301)
t3 – time between activation 1 and 2 relay (parametr 39)
t4 – time activation 2 of relay (parametr 372)
t5 – time between pulses 1 of relay (parametr 302)

Tab. 1 Table of relay(s) control

3.3 Person inside building


By person inside building we mean person in telephone connection with
Brave intercom , for example Mr. Scott.
3.3.1 Outgoing call
Outgoing call is a call from door intercom (generated by visitor). After door
intercom dial is ringing a phone inside the building. When you pick up the phone
you can talk to visitor. By code dialling you can activate the relay (parametr 35) -
when relay is setup in mode m=1 or m=5. You also can switch operation mode
DAY/NIGHT (parametr 45,46) and hang up (parametr 43). Door intercom sends
10sec before call ending (parametr 52) alerting tone and you can prolong the
call by dialling special character from phone (parametr 42). By phone hanging
up the call is ended (PBX generates busy tone into the line which is detected
and door intercom hangs up). There is one more option which is hang up the
line by again push of the same button (parametr 4*).

24 BRAVE – user guide


3.3.2 Incoming call
Incoming call is a call into door intercom (generated by person inside the
building). After dialling extension number where is connected door
intercom the door interocm line is ringing. After setup number of rings
the door intercom picks up (parametr 51) and you can talk. Other
possibilities are the same like in case of outgoing call (capture 3.3.1).
• First exception is first 10sec where you can dial "# and service password"
(parametr 44). By this you enter programming mode of door intercom.
• Second exception is when DIP1 is switch to position ("SERVIS"). Then you
enter programming mode directly without dialling service password.
• Last exception is relay(s) control (parametr 381 and 382). You can by
programming prohibit to control relay(s) from incoming call .

BRAVE – user guide 25


4 Parametres programming
4.1 Programming by phone
4.1.1 Programming enter
You can enter programming mode by following ways:
1. password – incoming call only! – pick up the phone and dial phone
number where is door intercom connected (either extension number when
door intercom is connected to PBX or PSTN line number of building where is
door intercom installed and let operator connect you to appropriate door
intercom extension). Door intercom picks up (you hear pick up acoustic
tone – via. capture 3.1 page.21) and you have to dial within 10 sec
#xxxx, when xxxx is service passsword to enter programming mode
(default xxxx=0000). When all is correct you hear acoustic tone of
programming mode enter and after a while you hear programming tone
(via. capture 3.1 page.21).
2. switch "SERVIS" – incoming call only! – the connection you establish
the same way like in item 1. but only when DIP1 switch is in position
"on". Then door intercom after picks up going directly into programming
mode without neccessity to insert service password. (via. capture 3.1
page.21).
4.1.2 Parametres programming
Stand by stage of programming is announced by programming tone into
which door intercom always returns after time out (5sec) whenever you started
to programm.
There are two kind of parametres you can programm. First are parametres
with fix length – Most of parametres are those. The parametr is saved
immediatelly after inserting mandatory length – you hear confirmation tone.
Second are parametres with variable length (parametr 1, 2,32,33,34). Saving
and confirmation of those parametres is made after 5 seconds inserting last dial.
There is one case when those parametres are saved immediately and it is filling
up maximal number of characters (numbers) – at parametr 1 and 2 it is 24,
parametr 32,33,34 it is 6.
When during programming insert number(character) which is
unacceptable then door intercom sends error tone. The parametr is not saved
even changed. Door intercom returns to stand by and you can start again
parametr programming of programm other parametr.
When you enter programming mode and do not make any dialling for
30seconds the door intercom will hang up. After each dialled DTMF tone the
time is prolonged about 30seconds. You can finish programming mode also by
dialling parametr 9.

26 BRAVE – user guide


4.2 PC programming – BraveSet programm
For PC programming of door intercom you have to purchase special
USB cable USB-KAB and programm BraveSet ( free on every CD). Then you
have to connect door intercom into the line or at version /C or (C) switched ON
and connected power supply 12V - DIP3 and 4.
Procedure:
- Connect telephone line into door intercom or at version /C and (C) you can
use external power supply 12V (DIP 3,4)
- Connect special USB cable to PC USB socket . Door interocm picks up the
line within 3 seconds and play tone of programming enter (via. capture
capture 3.1 page.21).
- Run programm BraveSet. Door intercom is in programming mode during all
the time when programm BraveSet is running. The door intercom stays
pasive until moment of USB cable disconnection. When you loose
connection please disconnect USB cable from door intercom and connect it
again – door intercom picks up.
- Correct connection PC with BraveSet programm is indicated by reading
firmware version from door intercom ( visible in bar) as same as reading the
time ( shown in left top corner). When you have version (LC) then time is 0
because LC version doesnt includes RTC circuit.
For easy orientation are parametres in BraveSet programm marked by
the same codes like codes for programming by phone.
USB cable is special cable with galvanical isolation and with 3V
convertor. The galvanical isolation is neccessary because telephone line must
not be grounded and PC´s are usually grounded.

BRAVE – user guide 27


5 Descriprion of programmable parametres
Parametres always starts by fix, mandatory part ( adress) and variable
part – it is your dial. Range and explanation is always under each table . All is
dial like it is written in table. You dont dial any confirmation character. After
savings into memory you get back confirmation tone. When dialled value is
incorrect you get immediatelly error tone.

5.1 Direct numbers dial – memories


Parametr Value description Default
1 tt nn… Number nn under button tt -
tt – button number (memory), always has 2 digits [01-99]
nn – phone number up 24 digits which you desire to
save. For saving further characters use assignments description dial
mentioned in table. 0-9 0-9
Numbers saved in parametr 1 are numbers of first # #
group, or numbers of DAY mode. * **
Default settings doesnt erase as same as changed those Flash *#
saved numbers. Pause *0

Parametr Value Description Default


2 tt nn… číslo nn pod tlačítkem tt -
tt – button number (memory), always has 2 digits [01-99]
nn – phone number up 24 digits which you desire to
save. For saving further characters use description Dial
assignments mentioned in table. 0-9 0-9
Numbers saved in parametr 1 are numbers of second # #
group, or numbers of NIGHT mode. * **
Default settings doesnt erase as same as changed those Flash *#
saved numbers. Pause *0

Note: switching DAY/NIGHT mode stays in door intercom even after line disconnection
and version (C) this mode switch up current time (when this feature is activated -
parametr 084)
Note: at version Brave Slim - C and Brave Slim - LC are available max. 2 buttons -
tt=01-02

28 BRAVE – user guide


Settings examples:
1. first button should dial at DAY number 358 and in NIGHT 0_603441296 , you
programm it - 101358 and wait for ♫, next 2010 *0 603441296 and wait for ♫
2. second button should dial at DAY and NIGHT 123#1*2Flash3, you programm
102123#1 ** 2 *# 3 and wait for ♫, next 202123#1 ** 2 *# 3 and wait for ♫
Note. When you dont use mode of 2 group numbers or DAY/NIGHT mode we
recommend setup DAY/NIGHT mode (parametr 47) and next setup same code for
DAY/NIGHT switching (parametry 45 and 46). You provide by this that door intercom
will be always in DAY mode and then you programm numbers for DAY mode only
(parametr 1).

5.2 Relay(s)
Parametr Value Description Deafault
31 rm relay r works in mode m (1-8) 11 21
r – relay number [1-2]
m – relay mode [1-8 for r=1 is not mode m=5]
modes m=1,4,5,6 are detaily descriped in Tab. 1. on page 24
m=1 mode relay – activated by command (internal code) or password (external
code) 1 pulse for time t1/t4 (using for electrical locks) or 2 pulses when is
activated for time t1/t4, open for time t2/t5 and close for time t1/t4 (sliding
door opening)
m=2 closed for time of line OFF HOOK (camera) – close when door intercom
picks up and open by hanging up
m=3 closed for time of line OFF HOOK and more for time t1/t4 after hang up
(lighting) – closed when door intercom picks up and stays closed for time
t1/t4 after door intercom hangs up (for this time line is busy, at version /C
and C is after switching DIP 3,4 and settings parametr 64 for time t1/t4
line hanged up)
m=4 mode button – closed when any button is pushed and open after time
t1/t4 (usage for example: connection external bell)
m=5 mode progressive opening – you can setup into this mode relay 2 only
because relay 1 will be setup automatically into mode m=1. By command
(internal code) or password (external code) is activated relay 1 for time t1,
then is running time t3 before closing relay 2. Then is relay 2 activated for
time t4 and then door intercom hangs up. When dialled command or
password match to 2 pulses then in sequence will appear two pulses
separated by time t2/t5. Explained in Tab. 1
Note. The command or password for relay 1start whole sequence.When you use
command or password for relay 2 then you control relay 2 only the same like in
mode m=1.
m=6 closed up pushed button (setup in parametr 31r*). Due this you can select
one button for every relay its pushing activate appropriate relay for time
t1/t4. This mode serves as substitution of ring bell connected to Brave
system.
BRAVE – user guide 29
m=7 permanent closing / opening – usable at versions /C and (C) only, if
switching (DIP 3,4)+par.64. By command for pulse 1 is closed and for
pulses2 is opened. This stage stays in door intercom even after power/line
disconnection. This mode you can use for potting, glasshouse opening,
heating activation etc..
m=8 activated up DAY/NIGHT mode settings - usable at versions /C and (C)
only, if switching (DIP 3,4)+par.64. Version /C allows copying manual
DAY/NIGHT switching only. Version (C) allows copying setting from week
table switching time (when is activated - parametr 084) and then you can
use for example for heating control etc…

Parametr Value Description Default


button tt start relay closing r in mode m=6
31 r* tt (01-99)
01
r – relay number [1-2]
tt – button number (memory), always has 2 digits [01-99]
This parametr is for relay mode m=6 only. Value of tt designate from which
button start closing for time t1/t4 of relay r.

Parametr Value Description Default


In mode DAY + NIGHT password hh... for
32 rp hh... relay r, in order p=1-5, for 1 pulse -
and p=* for 2 pulses (00-999999)
In mode DAY password hh... for relay r, in
33 rp hh... order p=1-5, for 1 pulse and p=* for 2 -
pulses (00-999999)
In mode NIGHT password hh... for relay r,
34 rp hh... in order p=1-5, for 1 pulse and p=* for 2 -
pulses (00-999999)
r – relay number [1-2]
p – order [1 - 5] for 1 pulse. 5 passswords (external codes) from door
intercom buttons (external code of codelock)
p – order = *, then you can insert just one code (external code) for closing
by 2 pulses
hh... – password (external code) for relay closing from buttons [2 to 6 digits].
Tlačítka 1 - 10 are programmable as numbers 1-0.
Totally 3 x 12 passwords. Controlled by settings DAY/NIGHT.
Combination is inserting by door intercom buttons. Relay closing is influenced
by setup relay mode and switching DAY/NIGHT. When is setup mode 2 groups
of numbers the door intercom is permanently in mode DAY.
You have to keep certain rules for password dialling:
▪ First button of password select from at least used button for direct
dialling (-prolong dial time)

30 BRAVE – user guide


▪ Caution on numbers identity of password. When one password includes
other, for example:password for relay1 is 1234 and for relay 2 12345,
then always after pushing button 4 relay 1 will be activated and relay 2
wont be never acivated. When you select password for relay 2 234,
then after button 4 pushing both relays will be activated.
Note1. switching to DAY/NIGHT mode stays setup in door intercom even after power
(line) disconnection. At version (C), when is activated, then DAY/NIGHT switching is
done up time and week table.
Note2. when you insert parametres 32,33,34 do not use character # and * because
you cant select them from button panel. Number 0 represents button 10.

Parametr Value Description Default


command aa from phone for relay activating
35 r aa r 1 pulse (00-99,*0-*9)
155 266
r – relay number [1-2]
aa – command (internal code) from phone for relay activation [2 digits] /1
For both relays you can setup the same command (internal code) then both
relays are activated simultaneously. It is profitable to setup the same command
for relay activation as same as door intercom hang up (parametr 43) aa=bb.
/1 – command has always 2 digits but when you want control relay by 1 digit
only ( from keypad of phone) then you have possibility to programm " *a " where
a is one number only which activate the relay (star represents empty character
and must be on first digit position).
Example: 1 relay activated by internal code 48 - dial 35148 ♫
2 relay activated by internal code 8 - dial 352*8 ♫
By dialling on phone 8 you activate relay 2 by dialling 48 you activate both relays

Parametr Value Description Default


command aa from phone for relay activation
36 r cc r 2 pulses (00-99,*0-*9)
150 260
r – relay number [1-2]
cc – command (internal code) from phone for relay activation [2 digits] /1
For both relays you can setup the same command (internal code) then both
relays are activated simultaneously.
/1 – command has always 2 digits but when you want control relay by 1 digit
only ( from keypad of phone) then you have possibility to programm " *a " where
a is one number only which activate the relay (star represents empty character
and must be on first digit position).
Activation relay 2 pulses is suitable for example: at sliding gate which this way
can also substitute wicket for person entrance.

BRAVE – user guide 31


Example: command to activate relay1 with 1 pulse *8, command to hang up *8 and
command for activation relay2 with 2 pulses *9.
Dial: 352*8 ♫ , 432*8 ♫ , 362*9 ♫.
You are in communication with door intercom unit. Dial command for open sliding gate 9.
First pulse starts sliding the gate and second pulse stop it. The size of spot for person
entrance is according time between each pulses (parametr 30). After person etnering you
dial 8. The door intercom makes one pulse and hang up. Sliding gate is closing.

Parametr Value Description Default


time ss [sec] activation relay r for time t1/t4
37 r ss (00-99)
105 205
r – relay number [1-2]
ss – time t1 / t4 for which is relay closed 1 / 2 [2 digits 00-99], where time 00
means 0,5sec

Parametr Value Description Default


Control relay r during incoming call
38 rp (0/1)
11 21
r – relay number [1-2]
p – parametr which says permitted p=1 or forbidden p=0 control relay during
incoming call
To prohibit control of relay during incoming call has a sense for example by
relay2 in mode 1 by which you control sliding gate opening where door intercom
open the gate and after car passing the gate is closed. Then control by phone
could make unwillingly permanent gate opening.

Parametr Value Description Default


time xx [sec] between activation relay 1
39 xx and 2 in mode m=5 - time t3 10
(01-99)
xx – time t3 between activation relay 1 and 2 when mode m=5 is setup
(progressive opening) [2 digits 00-99] ], when time 00 means 0,5sec

Parametr Value Description Default


time zz [sec] between pulses when is
30 r zz closing for 2 pulses relay r - time t2/t5 105 205
(00-99)
r – relay number [1-2]
zz – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits
00-99], where 00 means 0,5sec

32 BRAVE – user guide


5.3 Basic parametres
Parametr Value Description Default
41 v Dial type v – tone / pulse (0/1) 0
v – dial type v=0 is DTMF tone dial, v=1 pulse dial

Parametr Value Description Default


42 z Character to prolong the call (* / #) *
z – character to prolong the call * or # (10sec before call termination door
intercom sends notification then you can prolong the call)

Parametr Value Description Default


Command to hang up door intercom by
43 g bb phone 155 266
(00-99,*0-*9)
g – command order [1-2] (they are two to be possibility hang up door intercom
when each relay is used)
bb – command to hang up door intercom by phone [2 digits] /1
It is profitable setup the same command to hang up door intercom as same as
activate relay (parametr 35,36) aa=bb or aa=cc
/1 – command has always 2 digits but if you want use 1 digit then you have
possibility insert " *a " where a is just one number which activate the relay (star
represents empty character and must be on first position). (Example at parametres
35,36)

Parametr Value Description Default


44 xxxx Service password (0000-9999) 0000
xxxx – service password to enter programming by phone (DTMF)

BRAVE – user guide 33


Parametr Value Description Default
Command to switch into DAY mode
45 dd (00-99,*0-*9)
11
Command to switch into NIGHT mode
46 nn (0099,*0-*9)
10
dd – command to switch into DAY mode [2 digits] /1
nn – command to switch into NIGHT mode [2 digits] /1
/1 - command has always 2 digits but if you want use 1 digit then you have
possibility insert " *a " where a is just one number which switch DAY/NIGHT
mode (star represents empty character and must be on first position).
Note. Switching into DAY or NIGHT mode stays setup even after power (line)
disconnection from door intercom

Parametr Value Description Default


47 e Door intercom dial mode (0/1) 1
e – dial numbers mode e=0 dial numbers from first and second group, e=1
numbers are dialled up DAY/NIGHT mode in door intercom
CAUTION !! setting of this parametr has a big influence to numbers dialling

Parametr Value Description Default


Feature of line hanging up by again push of
4* k the same button (0/1)
1
k – line hanging up by push of same button:
k=0 feature is switch off
k=1 again button push hang up the line
CAUTION !! setting of this parametr has a big influence to numbers dialling

34 BRAVE – user guide


5.4 Time parametres
Parametr Value Description Default
Number of rings before door intercom picks
51 q up incoming call (1-9)
2
q – number of incoming call rings . Door intercom picks up between rings and
2 sec after detection of q – th rings. Number is adjustable from 1 to 9.

Parametr Value Description Default


52 d Maximal call duration (0-9,*,#) 2
d – maximal time for which door intercom is OFF HOOK.
This time you can prolong by dial character during a time[min] Dial
call by phone (* or # - parametr 42). Setting of time is 0,5 0
up table. 1-9 1-9
15 *
30 #

Parametr Value Description Default


53 w Time between button push (1-9) 2
w – maximal time [sec] between button push [range 1-9]
▪ normal buttons
- relay activation – when time between push of 2 following buttons is
longer than time w then code is evaluated incorrectly.
- Number dial – when button which we push is first number in password
for relay activation then dial is delayed about this time w

BRAVE – user guide 35


Parametr Value Description Default
54 z Hanging up time during REDIAL (1-5) 2
z – time [sec] for which door intercom hangs up before pick up for REDIAL
(button push during call, busy tone detection) [range 1-5]

Parametr Value Description Default


55 z Time before start dialling (1-5) 1
z – time [sec] after door intercom picks up and before start dialling [range 1-5].
This time is different for every PBX but usually all PBXs accepts dial within 2
seconds after line is picked up.

Parametr Value Description Default


56 hh Number of rings before hang up (04-99) 12
h – after dial termination calculate number of CRT (control ring tones). When
number is higher than hh then hang up [range 04-99]. Dial is repeated in
case of 2 groups mode.

Parametr Value Description Default


500 x Middle frequency of tones detector (1-0) 3 (375-475Hz)
501 y Number of busy tones (2-0) 4
502 z Time of permanent tone duration (1-5) 3 (3s)
x – middle frequency of tones detector – is suitable when PBX signalling is
unusual: frequency x - dial
[Hz]
275-375 1
325-425 2
375-475 3
425-525 4
475-575 5
525-625 6
575-675 7
y – minimal number of busy tones neccessary for 625-725 8
detection [2-0], where 0 means 10 busy tones 675-775 9
z – minimal time of permanent tone duration (for dial 725-825 0
tone detection on PBX) [1-5 sec]
Parametr Value Description Default

36 BRAVE – user guide


Time of tone duration DTMF (tone) dial
503 tt (04-16)
10 (100ms)
Time of space duration between DTMF
504 mm tones (04-16)
10 (100ms)

505 f Time of Flash duration (1-6) 1 (100ms)


Time of pause duration / pause between
506 p numbers 4 (800ms)
(1-0)
tt –Time of tone duration DTMF (tone) dial is calculated up:
(inserted number) x 10 = tone duration time [ms]
[range 04-16 tj. 40-160ms]
m – Time of space duration between DTMF tones is calculated up:
(inserted number) x 10 =pause duration time [ms]
[range 04-16 tj. 40-160ms]
f – Time of Flash duration is calculated:
inserted number x 100 = Flash duration time [ms]
[range 1-6 tj. 100-600ms]
p – Time of pause duration is calculated:
inserted number x 100 + 400 = pause duration time [ms]
[range 1-0 tj. 500-1400ms]
– time p is also time of pause between numbers at pulse dialling

Parametr Value Description Default


Level of sending tone DTMF dial in
507 uu [-dBm](04-16)
10
uu – level of sending tone (DTMF) dial into line, range is -4 to -16dBm. You
insert desired level, uu=04 is -4dBm, uu=10 is -10dBm
Parametr Value Description Default
508 p preemphase DTMF (0/1) 0
509 S Listening –in DTMF - level (1-4) 2
p – preemphase is rate between upper and lower groups of DTMF frequency.
You can select rate 2,2 dB - p=0 (Europe) or rate 3,2dB - p=1 (Australia)
s – listening –in DTMF level you can select in four levels:
Level of listening in DTMF [dB] s - dial
-15 1
-9 2
-3 3
+3 4

BRAVE – user guide 37


5.5 System parametres
Parametr Value Description Default
Acoustic signalling (confirmation, error, empty
61 z memory, call termination...) (0/1)
1
In default the stages of door intercom are acoustically signalling. By parametr
„z“ you can switch off this signalling. Possible values are
z=0 – signalling is off
z=1 – signalling is on

Parametr Value Description Default


Acoustic signalling off hook/on hook
62 v (0/1/2)
1
In default is signalling pick up and hang up of the line. If you identify some
problems at certain PBXs you can switch it off by parametr „v“ . The possible
values are:
v=0 – signalling OFF HOOK / ON HOOK is off
v=1 – signalling OFF HOOK / ON HOOK is on (type 1)
v=1 – signalling OFF HOOK / ON HOOK is on (type 2)

Parametr Value Description Default


63 u Acoustic signalling knocking to call (0/1) 0
In default it is switch off. By activation of this feature you can identify at PBX
calling from door intercom just up knocking into call. Possible values are:
u=0 – knocking to call is off
u=1 – knocking to call is on

Parametr Value Description Default


Powering from external power supply 12V
64 w (DIP 3,4) (0/1)
0
In version /C only or at version (C) .
In default external power supply is OFF.
Activation has a sense only in cases when door intercom should make some
operation during stand by mode – relay activation. Relay in mode m=7 allows
permanent closing even after call termination. Relay mode m=8 allows
activation up DAY/NIGHT mode settings even after call termination. In those
cases you have to provide external power supply to dont flow current at hanged
up line. The DIP switch 3 and 4 must be in position „on“ to activate this parametr
w=1 . Deactivation - w=0.

38 BRAVE – user guide


Parametr Value description Default
65 z Acustic signalling of relay activation (0/1) 0
In default the activation is off z=0. Usually you can use this fetaure for DC power
supply 12V. Then when el.lock is released you dont hear „buzzing“ so visitor
doesnt know that el.lock is released. When you activate this feature z=1 then
during relay activation you hear special sounds simulating relay activation.
Note.1 This feature is available for relay mode m=1, m=5 only.
Note.2 For relay activation with 2 pulses the acoustic signalling sounds during
whole time of sequence. (even in space between pulses)

Parametr Value Description Default


Suppression of DTMF reception from
66 i microphone (0/1)
0
In default the suppression of DTMF reception from MIC is off i=0. Due this you
can activate relay by personal dialler without ringing to person inside building. To
increase security you can activate suppression of DTMF reception from
microphone i=1 and due this protect entrance of persons who provided record of
DTMF code for door opening.

Parametr Value Description Default


BabyCall – call without neccessity programm
67 b phone number (0/1)
0
In default is switch off b=0. By activation this feature b=1 is cancelled acoustic
signalling of empty memory. After pushing of button with empty memory you get
just beep (confirmation) and call is established as normal dialled number
Caution: first 10sec of call is not active tone detector (it waits on reaction of PBX
and number dialling by PBX)

Parametr Value Description Default


delay start for PBx´s with line testing
6* t (Siemens) (0/1)
0
In default is switch off t=0. By activation this feature t=1 is processor going to
„sleep mode“ after line connection and after 3sec the door intercom makes
initialization. It delays line picks up after line ( voltage) connection – activation
status / PBX restart. When this feature is not efficient and PBX still evaluate the
line into „failure“ mode“ then you have to use external power supply – put DIP
switch 3 and 4 to position "on" – possible at version /C (C) only. It is the same
like using Best Box option.

BRAVE – user guide 39


5.6 HandsFree parametres setting
Parametr Value Description Default
Reception loudness 01-16 (16 is highest)
71 gg (SPK)
07
Transmission loudness 01-16 (16 is highest)
72 ff (MIC)
07
Speaker loudness 01-16 (16 is highest)
73 rr (TRH)
07
gg / ff / rr – numbers are inserted always by 2 digits in range [01-16]
After reception of confirmation ♫ is new value immediatelly active and you can
test it.
Help: except inserting of direct values 01-16 you can add/ decrease amplification
+/- by buttons on phone * = - and # = +
Limits of maximal and minimal loudness
are acoustically signalling (3 tones as
call termination signalling. When you
dont press any digit within 5sec then
setup value is saved and you hear
confirmation tone ♫.
CAUTION !! We dont recommend factory setting if neccessary.

Parametr Value Description Default


74 c Soft pass of switching (0/1) 1
In default this feature is off c=0. It is going about character of on line operation
semiduplex switching. In case where character of depresser is too steep you can
make it softer by c=1.

Parametr Value Description Default


75 n Depression of background sound (0/1) 1
In default it is off n=0. When door intercom is installed in noicy environment
(noicy streets, subway stations, parkings…) then by activation of this circuit n=1 is
setup level of noice as start level for microphone activation. Then the call
connection is not one way opened. It relates with setup of parametres 71, 76, 77.

40 BRAVE – user guide


Parametr Value Description Default
76 b Level of microphone start 1-4 (4 is highest) 2
On the line is simultaneously signal from microphone and speaker. In handsfree
circuit is a few functional blocks to suppress acoustic shock. The basic one is
circuit of semiduplex operation when incoming signal decrease microphone
amplificatio as same as signal from microphone decrease incoming signal. The
level of microphone start is setup by this parametr.. As lower value as higher
microphone sensitivity is. In noicy environment we recommend higher value with
combination of parametrs 71,75, 77.

Parametr Value Description Default


Fast switching voice automatic 1-4 (4 is
77 s slowest)
2
At parametres 75, 76 is descriped principal of acoustic shock supression. Speed
of circuit switching between incoming and outgoing sound is setup by parametr
77. Switching time S - dial
[ms]
1 1
2 2
4 3
8 4

Parametr Value Description Default


VoltAmper (VA) charakteristic of line
78 l connection (0/1)
1
Almost every country around the world has different telephone directives and this
parametr allows decrease voltage at door intercom line interface about 1V during
OFF HOOK. Where directive requires decreasement of line voltage I=0 decrease
voltage about 1V. In default l=1.

BRAVE – user guide 41


Parametr Value Description Default
Compemsation of wires losses depends on
79 k line current (0/1/2)
1
Door intercom Brave includes circuit which during long distance installations
(100m and more from PBX) can compensate losses on wiring. In default the
feature is off k=0. You can setup in two levels depending on line current of PBX
(short circuit current I0).
PBX current I0 k - dial
Feature is off 0
20mA-50mA 1
45mA-75mA 2

Parametr Value Description Default


Transmission signalling level in [-dBm] (04-
70 uu 16)
10
uu – transmission signalling level to the line, range -4 to -16dBm. You insert
desired level, uu=04 is -4dBm, uu=10 is -10dBm ...

42 BRAVE – user guide


5.7 Time programm – automatic DAY/NIGHT switching (C)
(C) version only !

Parametr Value Description Default


ON / OFF automatic DAY/NIGHT switching
09 a and setting time control (0/1/#)
0
When door intercom Brave includes RTC circuit - (C) version then you can
activate automatical switching from real time a=1. The condition is correct time
settings. You can verify it easily by diallingu a=# and door intercom reply either by
confirmation tone (all is correct) or error tone (you have to setup the time). By dial
a=0 you deactivate automatical switching.

Parametr Value Description Default


081 hhnn Time settings hh-hours, nn-minutes -
Date settings dd-day, mm-month, yy-year,
082 ddmmyyw
w-weekday
-

083 # wait 1 min for seconds zeroing -


Internal clocks parametres setting. After setting by command 083# zeroing
seconds setting any through this agreed clocks exactly up seconds.
w - weekday: 0 - Sunday
1 - Monday
2 - Tuesday
3 - Wednesday
4 - Thursday
5 - Friday
6 - Saturday

Example: you want set 27.5.2011 9:39 (its Friday), then dial sequence:
0822705115 you hear tone ♫, then dial 0810939 hear tone ♫ and finally dial 083
– wait for exact time sec=0 . In this moment dial # and you hear tone ♫ - finished.

BRAVE – user guide 43


Parametr Value Description Default
sunday – time setting hours hh and minutes
00 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
monday - time setting hours hh and minutes
01 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
tuesday - time setting hours hh and minutes
02 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
wednesday - time setting hours hh and
03 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
thursday - time setting hours hh and
04 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
friday - time setting hours hh and minutes
05 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
saturday - time setting hours hh and
06 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
overwrite (copyright) setting from sunday
07 # (00) into whole week
-
By parametres 00-06 are setting times of automatic switching DAY/NIGHT for
every day in week. The parametr 07 is designed for copying when setting is the
same for whole week. Then you setup switching times for parametr 00 (sunday)
and then by parametr 07# you copy this setting into remaining days.
Examples:
1. monday 8:00 starts day, 17:05 starts night, tuesday 7:30 starts day and in 16:00 starts
night.
Setting sequence: 0108001705 and ♫, then 0207301600 and ♫
2. In Thursday starts day 6:45 and night starts 15:05, on Friday night continue until 15:00
and then starts day and it is until saturday 12:00 , then is night. Here you can use
setting of switching inside one day into night even night is still valid from previous day
and again switching into day even day is valid from previous day. Then for setting after
midnight you insert time 00:00.
Setting sequence: 0406451505 and ♫, 0515000000 and ♫, 0600001200 and ♫

44 BRAVE – user guide


5.8 Default settting and erasing
Parametr Value Description Default
8# # Default execute
This setting doesnt change parametres 1 and 2 (numbers saved in memories)

Parametr Value Description Default


Erase all numbers in group 1
81 (Day mode)
Erase all numbers in group 2
82 (Night mode)
83 Default settings for parametres 3x only 3 only..
84 Default settings for parametres 4x only 4 only..
85 Default settings for parametres 5x only 5 only..
86 Default settings for parametres 6x only 6 only..
87 Default settings for parametres 7x only 7 only..
80 Default settings for parametres 0x only 0 only..
Parametres 81 and 82 makes erasing of all numbers saved in button memories.
Parametres 83 – 87,80 makes default settings for parametres starts 3,4,5,6,7,0
only. Default settings values are mentioned at every parametr in right - column
"Default".
CAUTION !!! the erasing is unreturnable !!! it is neccessary programm again

5.9 Programming termination


Parametr Value Description Default
9 E N D of programming
After 9 dial in programming tone the door intercom hangs up.

BRAVE – user guide 45


5.10 Parametres overview
Parametr Value Description Default
1 tt nn… number nn under button tt -
2 tt nn… number nn under button tt -
31 rm relay r works in mode m (1-8) 11 21
button tt activate relay closing r in mode
31 r* tt m=6 (01-99)
01
In mode DAY + NIGHT password hh... for
32 rp hh... relay r, in order p=1-5, for 1 pulse -
and p=* for 2 pulses (00-999999)
In mode DAY password hh... for relay r, in
33 rp hh... order p=1-5, for 1 pulse and p=* for 2 pulses -
(00-999999)
In mode NIGHT password hh... for relay r, in
34 rp hh... order p=1-5, for 1 pulse and p=* for 2 pulses -
(00-999999)
command aa from phone for closing relay r
35 r aa 1 pulse (00-99,*0-*9)
155 266
command aa from phone for closing relay r
36 r cc 2 pulses (00-99,*0-*9)
150 260
time ss [sec] relay closing r for time t1/t4
37 r ss (01-99)
105 205
Relay control r during incoming call
38 rp (0/1)
11 21
time xx [sec] between relay closing 1 and 2
39 xx in mode m=5 - doba t3 (01-99)
10
time zz [sec] between pulses during closing
30 r zz for 2 pulses of relay r - doba t2/t5 (01- 105 205
99)
41 v Dial type v – tone / pulse (0/1) 0
42 z Character for call prolongation (* / #) *
Command to hang up door intercom by
43 g bb phone 155 266
(00-99,*0-*9)
44 xxxx Service password (0000-9999) 0000
45 dd Command to switch into DAY (00-99,*0-*9) 11
46 nn Command switch into NIGHT (0099,*0-*9) 10
47 e Door intercom dial mode (0/1) 1
Feature of line hanging up by again push of
4* k the same button (0/1)
1

46 BRAVE – user guide


Number of rings before door intercom pick
51 q up incoming call (1-9)
2
52 d Maximal call duration (0-9,*,#) 2
53 w Time between button push (1-9) 2
54 z Hang up time before REDIAL (1-5) 2
55 z Time before dial start (1-5) 1
56 hh Number of ringing before hang up (04-99) 12
500 x Middle frequency of tone detector (1-0) 3 (375-475Hz)
501 y Number of busy tones (2-0) 4
502 z Duration time of permanent tone (1-5) 3 (3s)
Duration time of tone DTMF of tone dial
503 tt (04-16)
10 (100ms)
Time of space between each DTMF tones
504 mm (04-16)
10 (100ms)
505 f Flash duration time (1-6) 1 (100ms)
Pause duration time / space between
506 p numbers (1-0)
4 (800ms)
Transmitting level of DTMF dial in [-dBm]
507 uu (04-16)
10
508 p preemphase DTMF (0/1) 0
509 S Listening in DTMF – level (1-4) 2
Acoustic signalling (confirmation,error, empty
61 z memory, call termination...) (0/1)
1
Acustic signalling OFF HOOK /ON HOOK
62 v (0/1)
1
63 u Acoustic signalling of beeping into call (0/1) 0
External powering from power supply 12V
64 w (DIP 3,4) (0/1)
0
65 z Acoustic signalling of relay activation (0/1) 0
Depression of DTMF reception from
66 i microphone (0/1)
0
BabyCall – call without neccessity to insert
67 b phone number (0/1)
0
Delay start for PBX´s with extension test
6* t (Siemens) (0/1)
0
Reception loudness 01-16 (16 is highest)
71 gg (SPK)
07
Transmission loudness 01-16 (16 is highest)
72 ff (MIC)
07
73 rr Speaker loudness 01-16 (16 is highest) 07
BRAVE – user guide 47
(TRH)

74 c Soft pass of switching (0/1) 1


75 n Depression of background sound (0/1) 1
76 b Level of microphone start 1-4 (4 is highest) 2
Fast switching voice automatic 1-4 (4 is
77 s slowest)
2
VoltAmper (VA) charakteristic of line
78 l connection (0/1)
1
Compemsation of wires losses depends on
79 k line current (0/1/2)
1
Transmission signalling level in [-dBm] (04-
70 uu 16)
10
ON/ OFF automatic switching DAY/NIGHT
09 a mode and time settings control (0/1/#)
0
081 hhnn Time settings hh-hours, nn-minutes -
082 ddmmyy Date settings dd-day,mm-month,yy-year -
083 # Wait for 1 min for seconds zeroing -
sunday - time setting hours hh and minutes
00 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
monday - time setting hours hh and minutes
01 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
tuesday - time setting hours hh and minutes
02 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
wednesday - time setting hours hh and
03 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
thursday - time setting hours hh and
04 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
friday - time setting hours hh and minutes
05 hhnnkkjj nn starts day and hours kk and minutes jj 00000000
starts night
saturday - time setting hours hh and
06 hhnnkkjj minutes nn starts day and hours kk and 00000000
minutes jj starts night
overwrite (copyright) setting from sunday
07 # (00) into whole week
-

8# # default execute
Erase all numbers in group 1
81 (DAY mode)

48 BRAVE – user guide


Erase all numbers in group 2
82 (NIGHT mode)
83 Default setting for parametres 3x only 3 only..
84 Default setting for parametres 4x only 4 only..
85 Default setting for parametres 5x only 5 only..
86 Default setting for parametres 6x only 6 only..
87 Default setting for parametres 7x only 7 only..
80 Default setting for parametres 0x only 0 only..
9 END

BRAVE – user guide 49


6 Technical parametres
6.1 Elektrical parametres
Parametr Value Conditions
Minimal line current 18mA Line OFF HOOK
Minimal line voltage 18V Line ON HOOK
Line voltage during OFF HOOK < 8V I = 20mA
(VA characteristic) < 12V 1) I = 60 mA
Downlead during ON HOOK < 30uA U = 60V
220R +
Line termination impedance Line OFF HOOK
820R paral. 115nF
Bandwidth 300Hz – 3400 Hz 20 - 60mA
Ringing impedance > 2Kohm 25 – 60 Hz
Sensitivity of ringing detector min. 10 – 25 V
Pulse dial 40 / 60 ms
-6 and -8 dB
Tone dial level 1) 20 – 60 mA
Sensitivity of tone dial min. -40 dB 20 – 60 mA
Sensitivity of tones detector min. -30 dB 20 – 60 mA
Powering of backlight, relays and
12Vss ± 2V , 10-12Vst ± 2V
heating
Max consumption of backlight
250mA 12Vss
and heating
Max voltage of relay contact 48V when I < 1A
Max current of relay contact 1,5A when U < 30 V
Operation temperature - 20 to + 60 st
IP rate IP44
Weight max. 350g
Camera Parametres on page 18
1) - possible setting by progam

6.2 Mechanical dimensions


Model dimension HxWxD [mm]
Brave Slim (1 and 2
185 x 99 x 40
buttons)
Weather hood 68 x 103 x 60
Brave with weather hood 187 x 103 x 60
Screw 2x screw 3.5x30 halfround head
Wall plug 2x UPA,UPP pr. 5 x 25

50 BRAVE – user guide


7 Table for easy programming
Into empty parts of table write values which you desire to programm. In
double linked part are mentioned programming commands for easy
programming. Moreover the programmed values stay in manual for future
changes.
Description Programming sequence
digits
description detail par. Fill up your values

Number under button 1 Day/1gr. 101 24


Number under button 2 Day/1gr. 102 24
Number under button 3 Day/1gr. 103 24
Number under button 4 Day/1gr. 104 24
Number under button 5 Day/1gr. 105 24
Number under button 6 Day/1gr. 106 24
Number under button 7 Day/1gr. 107 24
Number under button 8 Day/1gr. 108 24
Number under button 9 Day/1gr. 109 24
Number under button 10 Day/1gr. 110 24
Number under button 11 Day/1gr. 111 24
Number under button 12 Day/1gr. 112 24
1 Number under button Night/2gr 201 24
2 Number under button Night/2gr 202 24
3 Number under button Night/2gr 203 24
4 Number under button Night/2gr 204 24
5 Number under button Night/2gr 205 24
6 Number under button Night/2gr 206 24
7 Number under button Night/2gr 207 24
8 Number under button Night/2gr 208 24
9 Number under button Night/2gr 209 24
10 Number under button Night/2gr 210 24
11 Number under button Night/2gr 211 24
12 Number under button Night/2gr 212 24
relay 1 works in mode m=1 - 8 311 1
relay 2 works in mode m=1 - 8 312 1
Password for relay 1 (1 pulse) Day+Night 3211 6
BRAVE – user guide 51
password relay 1 (1pulse) Day/Night 3212 6
password relay 1 (1pulse) Day/Night 3213 6
password relay 1 (1pulse) Day/Night 3214 6
password relay 1 (1pulse) Day/Night 3215 6
password relay 1 (2pulses) Day/Night 321* 6
password relay 2 (1 pulse) Day/Night 3221 6
password relay 2 (1 pulse) Day/Night 3222 6
password relay 2 (1 pulse) Day/Night 3223 6
password relay 2 (1 pulse) Day/Night 3224 6
password relay 2 (1 pulse) Day/Night 3225 6
password relay 2 (2 pulses) Day/Night 322* 6
Password relay 1 (1 pulse) Day 3311 6
Password relay 1 (1 pulse) Day 3312 6
Password relay 1 (1 pulse) Day 3313 6
Password relay 1 (1 pulse) Day 3314 6
Password relay 1 (1 pulse) Day 3315 6
Password relay 1 (2 pulses) Day 331* 6
password relay 2 (1 pulse) Day 3321 6
password relay 2 (1 pulse) Day 3322 6
password relay 2 (1 pulse) Day 3323 6
password relay 2 (1 pulse) Day 3324 6
password relay 2 (1 pulse) Day 3325 6
password relay 2 (2 pulses) Day 332* 6
Password relay 1 (1 pulse) Night 3211 6
Password relay 1 (1 pulse) Night 3212 6
Password relay 1 (1 pulse) Night 3213 6
Password relay 1 (1 pulse) Night 3214 6
Password relay 1 (1 pulse) Night 3215 6
Password relay 1 (2 pulses) Night 321* 6
password relay 2 (1 pulse) Night 3221 6
password relay 2 (1 pulse) Night 3222 6
password relay 2 (1 pulse) Night 3223 6
password relay 2 (1 pulse) Night 3224 6
password relay 2 (1 pulse) Night 3225 6
password relay 2 (2 pulses) Night 322* 6

52 BRAVE – user guide


Button selection for relay 1 m=6 311* 2
Button selection for relay 1 m=6 312* 2
Relay 1 activation by phone 1 pulse 351 2
Relay 2 activation by phone 1 pulse 352 2
Relay 1 activation by phone 2 pulses 361 2
Relay 2 activation by phone 2 pulses 362 2
Time of closing for relay 1 [sec] 371 2
Time of closing for relay 2 [sec] 372 2
Incoming call relay1 control 1/0 381 1
Incoming call relay2 control 1/0 382 1
Delay between closing
relay 1 and 2
[sec] 39 2
Time between pulses rel 1 [sec] 301 2
Time between pulses rel 2 [sec] 302 2
Leaving button relay 1 0/1/2 3*1 2
Leaving button relay 2 0/1/2 3*2 2
Dial type tone / pulse 0/1 41 1
Call prolongation character */# 42 1
Brave hanging up by phone 1. 431 2
Brave hanging up by phone 2. 432 2
Service password 44 4
Code to switch into DAY 45 2
Code to switch into NIGHT 46 2
Door intercom dial mode 1/0 47 1
Hang up by same button p. 0/1 4* 1
Number of rings for pick up 51 1
Maximal call duration [min] 52 1
Time between button press [sec] 53 1
Hang up time - REDIAL [sec] 54 1
Time before dial start [sec] 55 1
Numb of rings bef. Hang up 56 2
Tone detector frequency table 500 ms 1
Number of busy tones 501 1
Time duration of permanent
tone
502 sec 2
Time duration of tone dial nn x 10 503 ms 2

BRAVE – user guide 53


Space betweeni DTMF
tones
nn x 10 504 ms 2
Flash duration n x 100 505 ms 1
pause/ space between
numbers
n x100+400 506 ms 1
DTMF transmission level 04-16 507 -dBm 2
preemphase DTMF 0/1 508 1
Listening in DTMF - level 1-4 509 1
Acustic signalling 0/1 61 1
Acustic signalling Off hook
/on hook
0/1 62 1
Acustic signalling beeps 0/1 63 1
External power supply 12V 0/1 64 1
Acustic signalling of relay
activation
0/1 65 1
Depression of DTMF
reception from microphone 0 /1 66 1
BabyCall 0/1 67 1
Number of buttons on
panel
Up model 6# 1
Delayed start (Siemens) 6* 1
Reception loudness (TRH) 01-16 71 2
Transmission loudness
(MIC)
01-16 72 2
Speaker loudness (SPK) 01-16 73 2
Soft pass of switching 0/1 74 1
Depression of background
sound
0/1 75 1
Level of microphone start 1-4 76 1
Fast switching voice
automatic
1-4 77 1
VA charakteristic 0/1 78 1
Compemsation of wires
losses
0/1/2 79 1
Signalling transmission
level
04 - 16 70 -dBm 2

on/off.automatic switching 0/1/# 09 0


Time setting hhnn 081 4
Date setting+weekday w ddmmyyw 082 7
sunday hhnnkkjj 00 8
Monday hhnnkkjj 01 8

54 BRAVE – user guide


Tuesday hhnnkkjj 02 8
Wednesday hhnnkkjj 03 8
thursday hhnnkkjj 04 8
friday hhnnkkjj 05 8
saturday hhnnkkjj 06 8

BRAVE – user guide 55


Producer:

Distributor:

Sales date:

© JR 2011-12 verze 1.2 III/12