1"RSC PIPE

2-NO.8 TW WIRE
M IN 25mm ∅ RIGID PVC PIPE
1-NO.8 TW GROUND WIRE
IN 25mm ∅ RIGID PVC PIPE
40A,2P 15A,2P HOUSE 1 HOUSE 2
SERVICE WIRE SERVICE WIRE
MAIN 1 2 LIGHTING
20A,2P 20A

PROPERTY LINE
CONVENIENCE 3 4 CONVENIENCE
OUTLET(G/F) OUTLET(2/F)
AIRCON 5 6 SPARE
POLE PLAN PER UNIT
1- NO.8 TW
GROUND WIRE
RISER DIAGR AM PER UN IT
HOUSE
SERVICE WIRE
PROPERTY LINE
SCHEDULE OF LOADS AND COMPUTATION
CKT. NO. DESCRIPTION OF LOADS NO.OF OUTLET VA VA/CKT VOLTAGE IL/CKT BRANCH PROTECTION WIRES & CONDUIT ENTRANCE POLE KEY DIAGRAM
1 MAIN CKT. 1 40 AMP 3-#8 TW IN 1"Ø PVC RIGID PIPE
2 CEILING LIGHT OUTLET 18 100 1800 230 7.82 15 AMP 2-#14 TW IN 1/2"Ø FLEXIBLE PVC CONDUIT
3 CONVENIENCE OUTLET (GROUND) 5 180 900 230 3.91 20 AMP 2-#12 TW IN 1/2"Ø PVC RIGID PIPE
4 CONVENIENCE OUTLET (2ND FLR.) 6 180 1080 230 4.70 20 AMP 2-#12 TW IN 1/2"Ø PVC RIGID PIPE
5 AIRCON 1 746 746 230 3.24 30 AMP 2-#10 TW IN 1/2"Ø PVC RIGID PIPE
6 SPARE
POWER CONNECTED LOAD 1206 4526 230 19.68 0.20
DEMAND FACTOR 100%
TOTAL POWER CONNECTED LOAD 4526

1.80
COMPUTATION :

1.40
IL = 4526 = 19.68 AMP (100% DF)
230V
WIRE SIZE : USE 2-NO.8 TW COPPER WIRE(STRANDED),1-NO.8 TW COPPER WIRE(STRANDED)GROUND LINE
ON 1"Ø PVC CONDUIT

0.30
FOR MAIN CB : USE 2P 40 AT/100 AF 230V CB F.F.L.
NOTE:ALL CONCRETE EMBEDDED CONDUITS ARE RIGID PVC PIPES. LIGHTING CONTROL POWER OUTLET PANEL BOARD
ARCHITECT ENGINEER PROJECT TITLE: DESIGNED: SHEET CONTENTS REVISION SHEET NO.
AXEIA DEVELOPMENT CORPORATION DRAWN: B.S. JUSAY RISER DIAGRAM
LOADS AND COMPUTATION
LINNEA MODEL 77.25 SQ.M. SINGLE-ATTACHED
CHECKED:
LOCATION: DATE: 7/ 21/ 17
MOUNTING HEIGHT DETAIL
ENTRANCE POLE KEY DIAGRAM
E-2
PHOENIX SUN BUSINESS PARK, E. RODRIGUEZ JR. AVE., LIBIS Q.C.
REG. PTR NO. REG. NO. PTR NO.
TEL. NO. 9133373-80 BRGY. CALUMPANG, BINANGONAN RIZAL DATE:
DATE: PLACE: DATE: PLACE: