API Std 650 Storage Tank
Data Sheet PAGE 3
* For boxes marked with *, if blank, Mfr. Shall determine and submit as per Appendix L. For all lines, see Appendix L for line-by-line instructions.
GENERAL Special Documentation Package Requirements:
Address*
Mfg. Serial No.* Year Built* Edition & Addendum to API 650*
Address
Tank Designation
3. Owner/Operator Location
5. Products Stored:
DESIGN AND TESTING Purchaser to Review Design Prior to Ordering Material? Yes No
Design Pressure KPA External Pressure KPA Maximum Fill Rate M3PH Maximum Emptying Rate
Floatation Considerations? Yes No Flot. Suppl. Spec:* Applied Supplemental Load Spec.
8. Seismic Design? Yes No Appendix E Alternate Seismic Criteria Seismic Use Group
MBE Site Class D Vertical Seismic Design? Yes No Vertical Ground Motion Accelerator AV: 0.0438
Basis of Lateral Acceleration (Select one): Mapped Seismic Parameters? Ss S1 S0 ; Site-Specific Procedures: MCE
Freeboard Required for SUG I Design Roof Tie Rods @ Outer Ring?* Yes No
9. Wind Velocity for non-U.S. sites, 50-yr. wind speed (3-sec. Gust)* KPH
Top Wind Girder Style* Dimensions* Use Top Wind Girder as Walkway? Yes
10. Shell Design: 1-Ft Mthd?* Yes No ; Variable-Des-Pt Mthd?* Yes No Alternate ; Elastic Anal. Mthd?* Yes No
Plate Widths (Shell course heights) and Thicknesses * Numbers below Indicate Course Number.
1. 2. 3. 4. 5.
6. 7. 8. 9. 10.
11. 12. 13. 14. 15.
0.0438
No
Alternate
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 4
* If box is blank, Manufacturer shall determine and submit as per Appendix L.
11. Open-Top and Fixed Roofs: (See Sheet 6 for Floating Roofs) Open Top?* Yes No
For Non-Frangible Roofs: Seal Weld Roof Plates to Top Angle on the Inside? Yes No ; Weld Rafters to Roof Plates?
Roof-to-Shell Detail* Radial Projection of Horizontal Component of Top Angle* Inward Outward
Hydro-Test Fill Height* Settlement Measurements Required? Yes No Extended Duration of Hydro-Test:
Responsibility for Setting Water Quality: Purchaser Manufacturer Supplemental Test Water Quality Spec.
Test Water Source & Disposal Tie-In Locations Hydro-Test Appendix J Tank? Yes
Post-Pressure-Test Activities Required of the Manufacturer: Broom Clean Potable Water Rinse Dry Interior
Other
15. Inspection by in Shop;
Supplemental NDE Responsibility Supplemental NDE Spec.
(Purch., Mfg., Other)
Positive Material Identification? Yes No PMI Requirements:
Must Welds not exceeding 6 mm (1/4 in.) Be Multi-Pass? Yes No Must Welds greater than 6 mm (1/4 in.) Be Multi-Pass? Yes
Specify Additional Tolerances, if any, and Circumferential and Vertical Measurement Locations:
- Allowable Plumbness: Measure and Record at a Minimum of Locations or Every m (ft) around the Tank, at
the Following Shell Heights: (select one box): 1
/3 H, /3 H and H
2
Top of Each Shell Course Other:
- Allowable Roundness:** Measure Radius and Record at a Minimum of Locations or Every
around the Tank, at the Following Shell Heights (select one box):
Top of Tank, H 1
/3 H, 2/3 H and H Top of Each Shell Course Other:
**See Data Sheet Instructions for the Maximum Allowable Additional Radial Tolerance.
Approvals: Revisions: Title:
By: GHI Ck'd:
Drawing No.: Sheet
OF 10
Yes No
Yes No
in Field
No
m (ft)
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 5
16. Coatings:
Internal Coatings by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
External Coating by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
Under-Bottom Coating by: Per Spec.*
(Not Req'd., Others, Tank Mfg.)
20. Tank Measurement System: Required? Yes No Remote Capability Required? Yes No
23. Remarks:*
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 6 OF 10
Component Head Type* Bolt or Anchor Material* Nut Material* Thread Series* C.A.
Flange Bolting
Structural Bolting
Anchor Bolts
Table 3 NOZZLE and MANHOLE SCHEDULE* (for Fixed Roof, Shell, and Bottom)
Full Pen.
Neck Sch On Flange Gasket Bearing Proj. to FF or
Size, NPS, or Wall Reinf. Plate Open. Flange Class or Surf. Dimen. and Gasket Thick. Gasket Mat'l CL or from
Mark Service or Dia. (in.) Thick. Dimensions (Y/N) Type Thick. Finish and Dimen. and Descript. Datum Lines
SN01
SN03
SN02
SN04
SN02
SN04
SN02
SM01
RN02
RN03
RM01
24. Platform, Stairway, and Railing: Galvanizing Req'd?* Yes No Stairway Style* Walk Surf. Type*
(Straight or Helical)
Architectural/Structural Specification*
29. Various Other Items: Welded Flush-Type: Shell Connection Cleanout Fitting Waive Application of Appendix P? Yes
Miscellany #1 Miscellany #2
Miscellany #3 Miscellany #4
Miscellany #5 Miscellany #6
Service or
Mark Quantity Description Size Orientation Height from Datum Material Remark
Yes No
Yes No
Remarks
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 8 OF
31. Seals
Electrically Isolate Mechanism from Shoes? Yes No Wax Scrapers Required? Yes No
Roof-Drain Check Valves Required? Yes No Roof-Drain Isolation Valves Required? Yes No
Roof-Drain Piping to External Nozzles: Mfg. Std. Armored Flexible Pipe Swivels in Rigid Pipe Other
Guide Pole for Gauging? Yes No Slots in Guide Pole? Yes No Datum Plates? Yes No Striking Plates?
Guide Pole Emissions-Limiting Devices: Sliding Cover Pole Wiper Pole Sleeve Float Float Wiper
Removable Leg Storage Racks? Yes No ; Leg Sleeves or Fixed Low Legs
Design Rainfall Intensity in./hr. (mm/hr) Based on a Minute Duration Associated with the Storm
Yes No
Pole Cap
Storm
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 9 OF
Two-Position Legs? Yes No Cable-Supported Roof? Yes No Fixed-Roof Inspection Hatches Required?
Internal Roof Drain Required? Yes No Omit Distribution Pads Supporting Uniform Live Loads? Yes No
Corrosion Gauge Required? Yes No Fixed Ladder Required? Yes No ; Type of Roof Vent:*
Mfr. To Leak Test* % of Compartments in Assembly Yard in Erected Position Unknown; see separate contract term
Roof Erector's Flotation Test: w/ Tank Hydro at Completion of Roof at a Later Date Not Required
Flotation Test Media: Water Product (see H.6.6.1) Water Quality: Potable Other See Supplemental Spec.
Flotation Test Items Provided by Purchaser (see H.6.7): None List Attached
Responsible Party for Inspecting Roof During Initial Fill: Purchaser Other
Yes No
Not Required
C.A./Coating*
Date:
Sheet of
API Std 650 Storage Tank
Data Sheet PAGE 10 OF
Notes: