Tutorial 3
Tutorial 3
Tutorial 3
121 122
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
123 124
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
6) Open the Data Browser from Data or use F8 key (you can also use button or
button).
125 126
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
9) Input the required components from the component list and click the next button to go 11) click next to calculate Binary interaction between components.
to the next step.
127 128
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
14) Enter Vapor fraction, Pressure, total flow rate and composition of “HOTIN” stream, and
12) Click next ,and the message box below appears.
then click next .(you have to input two out of tree of Temperature, Pressure and vapor
fraction in the “State variables” panel).
Click OK button.
13) Enter Temperature, Pressure, total flow rate and composition of “COLDIN” stream, and
then click next .(you have to input two out of tree of Temperature, Pressure and vapor
fraction in the “State variables” panel). Assume 50 kmol/hr as the initial guess for the water.
15) Input the hot stream outlet temperature in exchanger specification panel.
129 130
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
16) Make sure that in the pressure drop tab, the pressure drop in both hot and cold sides are 18) Click “New”. Then accept the default ID for the spec.
set to zero.
19) Click “New” to define the water temperature at outlet stream as a variable.
17) To find the minimum flow rate of water go to Flowsheeting OptionÆ Design spe.
131 132
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
20) Type “CLDTMP” for the name and define the category and references, then click next 22) Define the mole flow rate of inlet water as a manipulate variable in the “Vary” tab, and
. set its limits and then click next .
Click next .
21) Type CLDTMP in the spec field and input 50 in the target and then click next . 23) The message box below appears.
133 134
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
24) The status bar indicates that the simulation were done successfully and the results are 26) You can see the water flow rate in Convergence Results.
available. (you can view results by clicking the button or the button).
135 136
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
Composition of feed
Component Molar flow rate (lbmole/hr)
Ethane 30
Propane 200
n-Butane 370
n-Pentane 350
n-Hexane 50
137 138
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
3) Add a DSTWU column from the Model library. 5) Draw the Inlet and Outlet streams.
6) Open the Data Browser from Data or use F8 key (you can also use button or
4) Click Material stream from the Model library.
button).
139 140
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
7) If you click the button the message below appear. 9) Input the required components from the component list and click the next button to go
to the next step.
10) Select Peng-Robinson equation of state in the Base Method and click next .
141 142
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
13) Enter Temperature, Pressure, total flow rate and components molar flow of “FEED”
11) Click next to calculate Binary interaction between components.
stream, and then click next .(you have to input two out of tree of Temperature, Pressure
and vapor fraction in the “State variables” panel).
12) Click next ,The message box below appears. 14) In the column specification set propane as light key with .99 recovery and n-butane as
heavy key with .01 recovery, set the condenser to partial condenser with vapor, enter the rest
given data and click next .
143 144
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
15) The message box below appears; Click “OK” to run the simulation:
17) If you click the button the message below appears.
16) The status bar indicates that the simulations were done successfully and the results are
available. (you can view results by clicking the button or the button). Click “OK” to see the results.
145 146
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
147 148
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
149 150
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
9) Input the required components from the component list and click the next button to go
7) If you click the button the message below appear. to the next step.
151 152
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
10) Select Peng-Robinson equation of state in the Base Method and click next . 12) Click next ,The message box below appears.
13) Enter Temperature, Pressure, total flow rate and components molar flow of “FEED”
stream, and then click next .(you have to input two out of tree of Temperature, Pressure
and vapor fraction in the “State variables” panel).
153 154
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
14) In the column specification assume that the molar Distillation rate is about 500 kmol/hr,
16) Input the Condenser pressure and the Column pressure drop, and click next .
set the condenser to Partial-Vapor condenser, enter the rest given data and click next .
17) To simulate the Column for 99% Ethane recovery in distillate and 100% i-Butane
recovery in bottom go to design spec and click “New”.
15) Enter 8 for the feed stage and set the “Convention” to on stream, then click next .
155 156
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
18) Set the spec type to “Mole recovery” and enter 0.99 for the target, and click next . 20) Select the distillate stream for available, and feed stream for base stream and click .
21) Click “New” to define variable for the spec, and accept the default ID.
19) Select Ethane for spec component and click next .
157 158
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
22) Set the variable type to “Distillate rate” and input the lower and upper bound for the 24) The status bar indicates that the simulation were done successfully and the results are
variable and click . available.(you can view results by clicking the button or the button).
159 160
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
26) You can see the results in the “Streams” and in Block results. Problem 4: Ammonia Production
Harber’s process:
N 2 + 3H 2 → 2 NH 3
is carried out at high temperature and pressure (T=930 °F and P=200 atm). In an ammonia
plant, the feed gas (74 % H2, 24.5 % N2, 1.2 % CH4, and 0.3 % Ar) at 300 °F and 500 Psi is
catalytically reacted to produce NH3. 65 % of the N2 is converted in the reactor. The
products of reaction are refrigerated to separate out 75 % of NH3 product per pass. The
remaining process stream is recycled back after being purged. Assume a total feed of 100
lbmol/hr and no pressure drop in the mixer. Simulate the process with Peng-Robinson
equation of state for the case when the purge fraction is 10 %.
27) Also to see the value of Distillate rate in this problem go to Block B1\ Vary page, Results
tab.
161 162
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
163 164
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
5) Select components from Components list. 7) Click Next button to calculated Binary Interaction between components.
6) Select the Peng Robinson equation of state from properties. 8) Add a material stream from Data Browser.
165 166
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
9) Enter temperature, pressure and composition in the Stream FEED Data Browser. 11) Double click on mixer to specify it.
10) Select a mixer from model library and drag in on the PFD and connect to feed stream. 12) Select a compressor from model library, pressure changers and drag in on the PFD.
167 168
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
13) Complete flowsheet by connecting streams. 15) Select a heater from model library, heat exchangers and drag in on the PFD.
14) Double click on compressor. Specify discharge pressure in specifications page. 16) Complete flowsheet by connecting streams.
169 170
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
17) Double click on heater. Specify temperature and pressure in specifications page. 19) Complete flowsheet by connecting streams.
18) Select a reactor stoichiometry from model library reactors and drag in on the PFD.
171 172
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
21) Add a reaction by clicking new button in reaction page. 23) Select a heater from model library and drag in on the PFD. Then complete flowsheet by
connecting streams
24) Double click on the heater and specify pressure and enter a temperature for the outlet
stream in which it becomes two phases.
173 174
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
25) Select a separator from model library and drag it on the PFD. Then complete flowsheet 27) For finding outlet temperature heater go to Flowsheeting Options and add a new Design
by connecting streams. Spec.
175 176
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
29) To define recovery ratio of ammonia first add a mole flow of ammonia in stream 6. 31) Define ammonia mole ratio in FORTRAN page.
177 178
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
33) In VARY page determine manipulated variable. 35) Select a fsplit from model library and drag in on the PFD. Then complete flowsheet by
connecting streams.
34) Run the ASPEN PLUS and view temperature stream 6 in results summary, convergence.
36) Double click on fsplit and enter 0.9 for Split fraction of recycled stream.
179 180
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS Process Simulation Using ASPEN PLUS
37) Connecting stream recycle to mixer. 39) The message box below appears:
40) The status bar indicates that the simulations were done successfully and the results are
available. (you can view results by clicking the button or the button)
181 182
© 2005, Process Design and Simulation Research Centre © 2005, Process Design and Simulation Research Centre
Process Simulation Using ASPEN PLUS
42) You can see the outlet temperature of block B5 in Convergence Results
183