Wiring Diagram
GK700 series are polarity free
Electric Strike Installation Instruction GK700 Series
GK700 series are ANSI sized electric strikes for metal and wooden door frames. They are designed for use with cylindrical locks and can be used with the optional GEM mechanical lock, LS-2000, or GEM electromechanical locks from the ML series. Both electric strikes can easily be configured to either fail-safe or fail-secure modes.
Door Status
Operating Voltage 12~28VDC/AC Voltage Tolerance 15% 230mA/12VDC ;140mA/28VDC Current Draw 440mA/12VAC ; 230mA/28VAC Operating Temperature -10C~+45C Humidity 0~95% Jaw Strength 1500 lbs static strength
N.O. contact output : open status N.C. contact output : closed status
GK750
Faceplate
Access Control Device Power supply 12~28VDC/AC
Blue: N.O. Green: COM. Yellow: N.C. Red: Red:
Door status switch Latch recess Keeper
Lip Cable
Door Status
N.O. contact output : open status N.C. contact output : closed status
N.C. contact or access relay for fail-safe setting N.O. contact or access relay for fail-secure setting
GK710
GK700
Blue: N.O. Green: COM. Yellow: N.C. (unmonitored)
12~28VDC/AC
Power supply
Access Control Device Red: Red:
N.C. contact output : unlocked status N.O. contact output : locked status
Gray: N.C. White: COM. Brown: N.O.
Locked or Unlocked Status
Mortise Mount on Wooden Frames
Optional Brackets
Lip extension brackets are recommended for door frames with wide jambs.
GK700 on Wooden Frames
I n s w in
GK750 on Wooden Frames
I n s w in
Copyright All Rights Reserved.
P-MU-GK710 Ver. A Published: 2012.01.09
2-1
How to Change Version
Loosen screw #1 first. Loosen screw #2 and fix it to the other end. Fix screw #1 next to its original place.
Butt Splice (IDC) Connector
Fail-Secure (Power to Open)
Fail-Safe (Power to Lock)
Place the wire inside the connector and use a crimp or pliers to press down on the head of the connector evenly.
Installation Instructions Figures below show GK700 installation steps which are the same as GK750.
Measure the vertical and horizontal position of the latch bolt on the door leaf
Mark the position of the latch bolt on the door frame
Fix the installation template supplied to the marked line
24m (GK7 m 00) 28m (GK7 m 50)
Drill the holes and cut the door off as indicated by the template
Fix the lugs tightly
Connect the power and test the electric strike before finally mounting the unit
Note
Ensure that there is a small space between the latch bolt and keeper when the door is closed and the latch bolt is in its locked position. This will relieve pressure on the solenoid and reduce the risk of failure of opening the door.
Copyright All Rights Reserved.