Ex250 Sen Eng

The document provides an operation manual for the SMC EX250 series Fieldbus device, detailing installation, wiring, and switch settings. It includes safety instructions, LED indications for operational status, and guidelines for setting up power supply and communication connections. Users are advised to refer to the SMC website for additional information and maintenance instructions.

Uploaded by

jindevk27
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views1 page

Ex250 Sen Eng

The document provides an operation manual for the SMC EX250 series Fieldbus device, detailing installation, wiring, and switch settings. It includes safety instructions, LED indications for operational status, and guidelines for setting up power supply and communication connections. Users are advised to refer to the SMC website for additional information and maintenance instructions.

Uploaded by

jindevk27
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Fieldbus device Summary of Product parts Switch Setting LED Indication

Operation Manual Display

Switch protective cover


Wiring
Wiring (for power supply, communication, input and output) and piping are done on only
3. Power supply wiring
Connect the power supply cable to the power supply connector of SI Unit.
Open the switch protective cover and set the switches with a sharp-pointed watchmakers
screwdriver etc.

MAC address one side. Cable connection NOTE


EX250 Series for EtherNet/IPTM On the side, make a space for wiring and piping. 1) Aligning the key groove with the power supply connector (plug) of SI Unit, plug the 1. Be sure to turn off the power supply before setting the switches.
power supply cable (socket). 2. Be sure to set these switches before use.
Ground terminal 1. Communication wiring 2) Tighten the lock nut on the cable side by turning it clockwise by hand. 3. After setting the switch, close the switch protective cover and tighten the screws with
Thank you for purchasing an SMC EX250 series Fieldbus device (Hereinafter Connect the Ethernet communication cable to the communication connector of SI Unit. 3) Confirm that the connector does not move. proper tightening torque. (Tightening torque: 0.6 Nm)
referred to as "SI Unit" ). Cable connection
Please read this manual carefully before operating the product and make sure you Input block connector 1) Aligning the key groove with the communication connector (4-pin, socket) of SI Unit, SW1
understand its capabilities and limitations. Please keep this manual handy for plug the Ethernet communication cable (plug). ON

future reference. Communication connector 2) Tighten the lock nut on the cable side by turning it clockwise by hand. 1
3) Confirm that the connector does not move.
Power supply connector M3 ground terminal 0 Display Description
1 2 3 4 5 6 7 8
OFF Insufficient power supply for solenoids
To obtain the operation manual about this product, please SOL
Green light ON Normal power supply for solenoids
IP address
refer to the SMC website (URL http://www.smcworld.com) or 192.168.0.X OFF Insufficient power supply for input and control
1 2
contact SMC directly. PWR
Green light ON Normal power supply for input and control
Refer to the operation manual EX250-IE1 / -IE2 / -IE3 for the SW1
X OFF The power supply for control is OFF
input block specifications, 1 2 3 4
Green light ON Operating normally
4 3 0 0 0 0 Remote control
and EX9-OET1 / -OET2 / -OEP1 / -OEP2 / PE1 for the output MS Green flashes Setting error (Device has not been configured)
1 0 0 0 1
block and power block specifications. Tie-rod (2 pcs.) Communication Red flashes Recoverable internal error
Output block connector SI unit communication 0 1 0 0 2
Accessory connector pin layout Manual set up of setting Red light ON Unrecoverable internal error
1 1 0 0 3 IP address OFF The power supply for control is OFF or IP address not set
NOTE : : : : :
D class grounding (with the ground resistance of 100 ohm or less) should be performed for Green flashes EtherNet/IPTM-level communication not established
0 1 1 1 14
Element Description ground terminal, and ground at one point. NS Green light ON Multiple EtherNet/IPTM-level communications established
1 1 1 1 DHCP mode
Communication connector Connect the EtherNet/IPTM line. Pin layout and connection diagram of Ethernet communication cable CLEAR/HOLD Red flashes Multiple EtherNet/IPTM-level communications time out
Power supply connector Supplies power to the solenoid valve, Output block, SI Unit and Input block. Model No.: EX9-AC EN-PSRJ Red light ON IP address duplicated
SW1
Safety Instructions Input block connector
Output block connector
Connects the Input block.
Connects the solenoid valve, Output block, etc.
M12 RJ45
Pin layout and connection diagram of power supply connector cable (unit: mm) 5 6 7
Item Description

Model No.: EX500-AP -S 0 - - AUTO: The communication setting is automatically selected.


These safety instructions are intended to prevent hazardous situations and/or Display LED display showing the SI Unit status. Communication
setting MANUAL: The communication setting follows
equipment damage. Switch protective cover Incorporates the internal switch setting IP address and communication method. 1 - -
M12 the setting result by the switch No. 6 and No. 7.
These instructions indicate the level of potential hazard with the labels of Ground terminal Used for grounding. 1 0 - Communication Communicated at 10 Mbps
"Caution", "Warning" or "Danger". They are all important notes for safety and must MAC address A unique MAC address of 12 hexadecimal number digits to each SI Unit. Cable core wire 1 1 - speed Communicated at 100 Mbps
be followed in addition to International standards (ISO/IEC) and other safety Terminal No. external color
1 1 - 0 Communication Communicated at half duplex
regulations. +Tx 1 1 White/Orange 1 - 1 method Communicated at full duplex
2 1 +Rx 2 2 Orange 3 2
-Tx 3 3 White/Green
CAUTION indicates a hazard with a low level of risk which, if 4 1 2 SW1
Caution: not avoided, could result in minor or moderate injury. 3 4
-Rx 4 4
5
5
6
Pin No.
1
Cable color: Signal name
Brown: 24 VDC +10%/-5% (for solenoid valves/output) 8
Description
5
6 Green 7 8 2 White: 0 V (for solenoid valves/output) 0 The output signal is cleared when the communication error occurs.
WARNING indicates a hazard with a medium level of risk
Warning: which, if not avoided, could result in death or serious injury.
Pin assignment of
plug connector
7
8
Pin assignment of
plug connector 4 3
3
4
Blue: 24 VDC ±10% (for input and control)
Black: 0 V (for input and control)
1 The output signal is held when the communication error occurs.

DANGER indicates a hazard with a high level of risk which, if


Danger: not avoided, will result in death or serious injury. Mounting and Installation Wiring diagram Shield Socket connector pin layout 5 Gray: Not connected

Model No.: PCA-140180


Operator Installation Cable specifications •Remote control (SW1 Dip switches 1-4 OFF)
Installation example: With solenoid valve connected
Core wire AWG26
M12
SMC's EX250 SI Unit will respond to the following Rockwell Automation BOOTP/DHCP
Server commands.
Maintenance
The operation manual is intended for those who have knowledge of machinery Sheath color Blue green SPEEDCON
using pneumatic equipment, and have sufficient knowledge of assembly, The number of solenoids Enable DHCP Refer to the operation manual from SMC website (URL http://www.smcworld.com) for more
= n (pcs.) Selecting this function will enable the EX250 SI Unit to retrieve its IP address∗ from the information about maintenance.
operation and maintenance of such equipment. Only those persons are Refer to "Media Planning and Installation Manual" of ODVA for detail of Wiring.
M4 x 6 BOOTP/DHCP Server. If DHCP is enabled the EX250 SI Unit will retrieve its IP address∗
allowed to perform assembly, operation and maintenance. Thickness: 13.2 during the next power up.
Read and understand the operation manual carefully before assembling, The number of Input Brocks
= m (pcs.) If the IP address∗ is not acquired after approximately 30 seconds from when the power is
operating or providing maintenance to the product. 2. Ground terminal
Connect the ground terminal to ground. 1 2
Pin No. Cable color: Signal name
supplied, the previous IP address∗ from immediately before will be set.
Disable BOOTP/DHCP
Troubleshooting
Resistance to ground should be 100 ohms or less. Selecting this function will disable the EX250 from retrieving its IP address∗ from the
Safety Instructions 5
1 Brown: 24 VDC +10%/-5% (Solenoid valve power supply)
BOOTP/DHCP Server, and will cause the EX250 to retain its current configuration during
Refer to the operation manual from SMC website (URL http://www.smcworld.com) for more
2 White: 0 V (Solenoid valve power supply) information about troubleshooting.
the next power up.
Warning 4 3
3 Blue: 24 VDC ±10% (Control power supply)

66
4 Black: 0 V (Control power supply) •DHCP mode (SW1 Dip switches 1-4 ON)
Do not disassemble, modify (including changing the printed circuit board) or repair. The IP address∗ is acquired from the DHCP Server. If the IP address∗ is not acquired after
An injury or failure can result. Socket connector pin layout 5 Green / Yellow: Not connected
approximately 30 seconds from when the power is supplied, the previous IP address∗ from
Do not operate the product outside of the specifications. immediately before will be set. The IP address∗ will be lost if the power supply is Specifications
Do not use for flammable or harmful fluids. disconnected.
Fire, malfunction, or damage to the product can result. Power for SI Unit/Input Block: 24 VDC ±20%, 1.1 A or less
•Manual set up of IP address∗
Verify the specifications before use.

Do not operate in an atmosphere containing flammable or explosive gases.


Fire or an explosion can result.
L2 = 21 x m + 89.8 L1 = 10.5 x n + 45
Connecting one or two power supplies to SI Unit
Both of single power supply and two power supply systems can be adopted, however,
the wiring should be made separately (for solenoid valves/output and for input and
The IP address∗ range is 192.168.0.1 to 192.168.0.14.
∗: Information such as the subnet masks is included. (
Inside of SI Unit: 0.1 A or less
Input block: 1 A or less (Depending on number of connecting
sensors and specifications)
Power for solenoid valve: 24 VDC +10%/-5%, 2 A or less
)
This product is not designed to be explosion proof. control) for both systems.
Installation example: With output block connected Default settings (Depending on number of solenoid valve station and
The number of The number of
At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable specifications)
If using the product in an interlocking circuit: A. Two power supplies
•Provide a double interlocking system, for example a mechanical system. Input Blocks Output Blocks and Power Blocks DHCP". Connection load: Solenoid valve with protection circuit for 24 VDC and 1.5 W or less surge
•Check the product regularly for proper operation. Power cable voltage. (made by SMC)
Otherwise malfunction can result, causing an accident. Operating ambient temp: 5 to 45 oC Storage ambient temp: -20 to +60 oC
Brown: 24 VDC (for solenoid valves/output) NOTE
White : 0 V (for solenoid valves/output) If the stored address of an EX250 is not known, please go to the "DHCP Mode" section. Pollution degree: Pollution degree 3 (UL508)
The following instructions must be followed during maintenance: 2 1
•Turn off the power supply.
24 VDC 5
•Stop the air supply, exhaust the residual pressure and verify that the air is released before performing Technical documentation giving detailed specification information can be found on the SMC
Blue : 24 VDC (for input and controlling)
66

maintenance. website (URL http://www.smcworld.com).


Otherwise an injury can result. Black : 0 V (for input and controlling) 3 4

24 VDC Power supply


Caution connector

When handling the unit or assembling/replacing units: B. Single power supply


Dimensions
•Do not touch the sharp metal parts of the connector or plug for connecting units. M4 x 4
•Take care not to hit your hand when disassembling the unit. Thickness: 13.2 Power cable Refer to the operation manual from SMC website (URL http://www.smcworld.com) for more
The connecting portions of the unit are firmly joined with seals. L3 = 21 x m + 93 information about dimensions.
Brown: 24 VDC (for solenoid valves/output)
•When joining units, take care not to get fingers caught between units.
An injury can result. ∗: The number of Input Blocks + The number of Output Blocks + The number of Power Blocks: m White : 0 V (for solenoid valves/output) 2 1
24 VDC 5
After maintenance is complete, perform appropriate functional inspections. L n,m 0 1 2 3 4 5 6 7 8 9 10
Stop operation if the equipment does not function properly. Blue : 24 VDC (for input and controlling)
L1 45 55.5 66 76.5 87 97.5 108 118.5 129 139.5 150
Safety cannot be assured in the case of unexpected malfunction. Black : 0 V (for input and controlling) 3 4
L2 89.8 110.8 131.8 152.8 173.8 194.8 215.8 236.8 257.8 278.8 299.8
Provide grounding to assure the safety and noise resistance of the Fieldbus system. Power supply
L3 114 135 156 177 198 219 240 261 282 303
Individual grounding should be provided close to the product with a short cable. connector
L n,m 11 12 13 14 15 16
NOTE L1 160.5 171 181.5 192 202.5 213 [mm]
URL http://www.smcworld.com
•The direct current power supply to combine should be UL1310 Class2 power supply ∗: L1 shows the dimensions of the VQC1000 series solenoid valve. Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
when conformity to UL is necessary. ∗: Each dimension shows the SI Unit without solenoid valves connected and with the end plate R (on the Output Phone: +81 3-5207-8249 Fax: +81 3-5298-5362
block side) connected.
Standard settings of L dimensions are with 10 or less m blocks. Contact SMC sales for the setting with over 10 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
blocks mounted. © 2009-2013 SMC Corporation All Rights Reserved EX※※-OMK0001-B

You might also like