Top 5 Lookout Specifications For Accelerometer
Top 5 Lookout Specifications For Accelerometer
Number 1: Sensor with Top Exit or Side Exit and Connector Options
The first choice is more of a preference. Side Exit Sensors require less clearance and
accommodate a flush installation. Due to their higher mass, they provide a lower
mounted base resonance frequency (22 KHz) than sensors with top exit (27 KHz)
but are still above the usual measurement frequency (10 KHz). Although the cost of
a Side Exit Sensor is about 10% higher, in recent years they became the leading
type in sensor sales.
Connector Options
The most common connector for standard accelerometers is the 2 Pin MS 5015
(Military Style). Another option is the circular M12 style connector, which is used
primarily in factory automation applications.
Shown above: Top Exit MS 5015 & M12 Connector; Side Exit MS 5015 & M12
Selecting a sensor with integral cable can save the cost for the cable connector
assembly. The disadvantage is that when the cable gets compromised (nicked) the
entire sensor may have to be replaced. Sensors with integral cables are great for
submersible applications, due to their excellent sealing.
The range can be extended by selecting a sensor with a lesser sensitivity, which is
explained next.
Sensitivity is the ratio of change in acceleration (input) to the change in the output
signal (Voltage).
The sensitivity of industrial accelerometers typically varies between 10 and 500
mV/g; with 100 mV/g being the standard. The range of vibration amplitude levels
to which the sensor will be exposed during measurements drives the sensitivity
selection.
Higher sensitivity accelerometers, such as 250 and 500 mV/g are for special
applications such as slow speed machinery (6 t0 60 rpm) with low frequency or low
amplitude measurements.
Low-sensitivity sensors are for monitoring high frequency applications such as roller
element defects in bearings and measuring gear mesh fault frequencies.
Sensitivity Precision
interest may be a harmonic (or multiple) of the running speed. The goal is to
determine the high frequency requirement of the application and choose a sensor
with an adequate frequency range, while also meeting sensitivity and amplitude
range requirements.
Typical Frequency Response for a 100 mV/g sensor, top exit, specified with
2 Hz (120 cpm) to 10 kHz (600 kcpm) at ± 5%
1.5 Hz (90 cpm) to 12 kHz (720 kcpm) at ± 10%
0.8 Hz (48 cpm) to 15 kHz (900 kcpm) at ± 3dB
The flat section of the horizontal response curve in blue defines the usable area.
General Vibration of rotating machinery with running speeds of 300 rpm to 7,200
rpm can be measured including defect frequencies at a fraction (BPFO, Ball Pass
Frequency Outer Ring) and multiples (BPFI, Ball Pass Frequency Inner Ring) of
running speed.
The hermetic seal standard on modern accelerometers helps prevent the intrusion
of contaminants or moisture.
Other Considerations
Noise levels can be defined in several ways. Some accelerometers will define
residual noise as a broadband RMS value, in [µV] or [µg]. This is calculated by
taking the root mean square of the signal without any mechanical excitation.
Mounting, the best mounting method uses a threaded stud for top exit and captive
mounting bolts for side exit sensors. Select thread size of studs/bolts to fit
mounting requirements.
Common Specifications
Examples, -please refer to the individual sensor data sheets for specific information.
Technical Performance
Mounted Base Resonance: 27 kHz (nominal) top exit and 22 kHz for side exit
Sensitivity: 100 mV/g Standard, optional 10, 30, 50, 250 or 500 mV/g
Isolation: Base Isolated
Transverse Sensitivity: Less than 5%
Electrical
Electrical Noise: 0.1 mg max
Current Range: 0.5 mA to 8 mA
Bias Voltage: 10-12 Vdc
Output Impedance: 200 Ohms max.
Case Isolation: >108 Ohms at 500 Volt
Environmental
Sealing: IP68 and IP65 for sensors with Integral Overbraided Cable
Maximum Shock: 5000 g
Operating Temperature: 130°C, 140°C or 150°C maximum, depending on sensor
category
Approvals: CE Approved
Mechanical
Case Material: Stainless Steel
Sensing Element: PZT/Compression
Mounting Torque: 5.9 lbs-ft (8 Nm)
Weight: 4.9 oz (139 gram) for top and 6.5 oz (185 gram) for side exit
Mounting, top exit: 1/4-28 UNF and M8x1.25 Mounting Studs Provided
Mounting, side exit: 1/4-28 UNF or M8x1.25 Captive Mounting Bolt