0% found this document useful (0 votes)
14 views

Modbus Setting in Relay

The document outlines the configuration parameters for Device1 in Project1, including settings for serial communication, input/output registers, and alarm functions. It specifies details such as baud rate, protocol standards, and various register addresses for binary inputs and outputs. Additionally, it includes information on analog inputs and alarm functions associated with the device.

Uploaded by

mohahm.ahm1998
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views

Modbus Setting in Relay

The document outlines the configuration parameters for Device1 in Project1, including settings for serial communication, input/output registers, and alarm functions. It specifies details such as baud rate, protocol standards, and various register addresses for binary inputs and outputs. Additionally, it includes information on analog inputs and alarm functions associated with the device.

Uploaded by

mohahm.ahm1998
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Project: Project1 Device name: Device1 Date: 25.2.

2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label1
SYMAP® Parameter Description
0300. SERIAL PORT 1 (ASC1) RS485 Selection of physical communication standard.
OFF / RS422 / RS485
0301. - address 1 This parameter defines the slave address of the device.
1..255
0302. - baudrate 9600 Baud rate for the communication.
9600..57600
0303. - protocol Modbus This parameter defines the protocol standard: PC-Tools:
reserved for all PC applications.Modbus:
activates the Modbus protocol.
transmission mode RTM mode: SYMAP® allows only the
Remote Terminal Mode, 8 bit coding system and
a CRC 16 error checking.
Startbit (fixed) 1
54. SERIAL PORT 1 - Stopbits 1 1 or 2
Parity (fixed) none

label2
label3

Page: 1
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label4
label5

Reg.Addr. Bit SYMAP® Terminal Fct. Binary Inputs basic unit


100 0 X2.3 30 10
100 1 X2.3 31 11
100 2 X2.3 32 12
100 3 X2.3 33 13
100 4 X2.3 34 14
100 5 X2.3 35 15
100 6 X2.3 36 16
100 7 X2.3 37 17
100 8 X2.3 38 18
100 9 X2.3 39 19
100 10 X2.3 40 20
100 11 X2.3 41 21
100 12 X2.3 42 22
100 13 X2.3 43 23

Reg.Addr. Bit SYMAP® Terminal Fct. Binary Outputs basic unit


101 0 X2.1 18 Shunt 1
101 1 X2.1 20 Shunt 2
101 2 X2.1 16 Lock Out Lockout relay set
101 3 X2.1 1 Synchron Function output set and delay time
101 4 X2.1 3 1 Function output set and delay time
101 5 X2.1 4 2 Function output set and delay time
101 6 X2.1 6 3 Function output set and delay time
101 7 X2.1 7 4 Function output set and delay time
101 8 X2.1 9 5 Function output set and delay time
101 9 X2.1 10 6 Function output set and delay time
101 10 X2.1 12 7 Function output set and delay time
101 11 X2.1 14 8 Function output set and delay time

Page: 2
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label6
Reg.Addr. Bit SYMAP® Terminal Fct. Binary Inputs extension unit
102 0 X40 64 24
102 1 X40 65 25
102 2 X40 66 26
102 3 X40 67 27
102 4 X40 68 28
102 5 X40 69 29
102 6 X40 70 30
102 7 X40 71 31
102 8 X41 73 32
102 9 X41 74 33
102 10 X41 75 34
102 11 X41 76 35
102 12 X41 77 36
102 13 X41 78 37
102 14 X41 79 38
102 15 X41 80 39
103 0 X42 82 40
103 1 X42 83 41
103 2 X42 84 42
103 3 X42 85 43
103 4 X42 86 44
103 5 X42 87 45
103 6 X42 88 46
103 7 X42 89 47

Reg.Addr. Bit SYMAP® Terminal Fct. Binary Inputs extension unit


103 8 X43 73 48
103 9 X43 74 49
103 10 X43 75 50
103 11 X43 76 51
103 12 X43 77 52
103 13 X43 78 53

Reg.Addr. Bit SYMAP® Terminal Fct. Binary Inputs ECG


103 14 X2.6 68/69 54
103 15 X2.6 70/71 55
104 0 X2.6 72/73 56
104 1 X2.6 74/75 57
104 2 X2.6 76/77 58
104 3 X2.6 78/79 59

Page: 3
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label7
Reg.Addr. Bit SYMAP® Terminal Fct. Binary Outputs extension unit
105 0 X46 3 60 Function output set and delay time
105 1 X46 4 61 Function output set and delay time
105 2 X46 5 62 Function output set and delay time
105 3 X46 6 63 Function output set and delay time
105 4 X47 7 64 Function output set and delay time
105 5 X47 9 65 Function output set and delay time
105 6 X47 11 66 Function output set and delay time
105 7 X47 12 67 Function output set and delay time
105 8 X47 14 68 Function output set and delay time
105 9 X47 16 69 Function output set and delay time
105 10 X47 19 70 Function output set and delay time
105 11 X47 22 71 Function output set and delay time
105 12 X48 25 72 Function output set and delay time
105 13 X48 28 73 Function output set and delay time
105 14 X48 31 74 Function output set and delay time
105 15 X48 32 75 Function output set and delay time
106 0 X48 34 76 Function output set and delay time
106 1 X48 35 77 Function output set and delay time
106 2 X48 37 78 Function output set and delay time
106 3 X48 39 79 Function output set and delay time
106 4 X48 40 80 Function output set and delay time
106 5 X48 41 81 Function output set and delay time
106 6 X48 42 82 Function output set and delay time
106 7 X48 43 83 Function output set and delay time

Reg.Addr. Bit SYMAP® Terminal Fct. Binary Outputs ECG

Page: 4
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

Reg.Addr. Bit Output register Event Description


117 0 Annunciator page 0 0
117 1 Annunciator page 1 0
117 2 Annunciator page 2 0
117 3 Annunciator page 3 0
117 4 Annunciator page 4 0
117 5 Annunciator page 5 0
117 6 Annunciator page 6 0
117 7 Annunciator page 7 0
117 8 Annunciator page 8 0
117 9 Annunciator page 9 0
117 10 Annunciator page 10 0
117 11 Annunciator page 11 0
117 12 Annunciator page 12 0
117 13 Annunciator page 13 0
117 14 Annunciator page 14 0
117 15 Annunciator page 15 0
118 0 Annunciator page 16 0
118 1 Annunciator page 17 0
118 2 Annunciator page 18 0
118 3 Annunciator page 19 0
118 4 Annunciator page 20 0
118 5 Annunciator page 21 0
118 6 Annunciator page 22 0
118 7 Annunciator page 23 0
118 8 Annunciator page 24 0
118 9 Annunciator page 25 0
118 10 Annunciator page 26 0
118 11 Annunciator page 27 0
118 12 Annunciator page 28 0
118 13 Annunciator page 29 0
118 14 Annunciator page 30 0
118 15 Annunciator page 31 0

Page: 5
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label12
Reg.Addr. SYMAP® Terminal Function
0 X2.4 55 Analog input 1
1 X2.4 56 Analog input 2
2 X2.4 57 Analog input 3
3 X2.4 58 Analog input 4

Reg.Addr. Output register Event Description


208 Analog input 5 Extension board
Analog input 1
209 Analog input 6 Extension board
Analog input 2
210 Analog input 7 Extension board
Analog input 3
211 Analog input 8 Extension board
Analog input 4
212 Analog input 9 Extension board
Analog input 5
213 Analog input 10 Extension board
Analog input 6
214 Analog input 11 Extension board
Analog input 7
215 Analog input 12 Extension board
Analog input 8
216 Analog input 13 Extension board
Analog input 9
217 Analog input 14 Extension board
Analog input 10
218 Analog input 15 Extension board
Analog input 11
219 Analog input 16 Extension board
Analog input 12
220 Analog input 17 Extension board
Analog input 13
221 Analog input 18 Extension board
Analog input 14
222 Analog input 19 Extension board
Analog input 15
223 Analog input 20 Extension board
Analog input 16

Page: 6
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label8
Reg.Addr. Bit Alarm No. Alarm Function
112 0 1 ,
112 1 2 ANSI 51 , OVERCURRENT TRIP
112 2 3 ANSI 51G/N GROUN , OVER CURRENT TRIP
112 3 4 UNDERVOLTAGE TRIP ,
112 4 5 50/ INSTANTANEOUS , OVER CURRENT TRIP
112 5 6 50G/N INST.GROUND , OVER CURRENT TRIP
112 6 7 LOCKOUT RELAY ,
112 7 8 ,
112 8 9 ,
112 9 10 ,
112 10 11 GAS PRESSURE , ALARM
112 11 12 AL.CHANNEL Nr.:12 , Text2 Chn. Nr.:12
112 12 13 AL.CHANNEL Nr.:13 , Text2 Chn. Nr.:13
112 13 14 AL.CHANNEL Nr.:14 , Text2 Chn. Nr.:14
112 14 15 AL.CHANNEL Nr.:15 , Text2 Chn. Nr.:15
112 15 16 AL.CHANNEL Nr.:16 , Text2 Chn. Nr.:16
113 0 17 AL.CHANNEL Nr.:17 , Text2 Chn. Nr.:17
113 1 18 AL.CHANNEL Nr.:18 , Text2 Chn. Nr.:18
113 2 19 AL.CHANNEL Nr.:19 , Text2 Chn. Nr.:19
113 3 20 AL.CHANNEL Nr.:20 , Text2 Chn. Nr.:20
113 4 21 AL.CHANNEL Nr.:21 , Text2 Chn. Nr.:21
113 5 22 AL.CHANNEL Nr.:22 , Text2 Chn. Nr.:22
113 6 23 AL.CHANNEL Nr.:23 , Text2 Chn. Nr.:23
113 7 24 AL.CHANNEL Nr.:24 , Text2 Chn. Nr.:24
113 8 25 AL.CHANNEL Nr.:25 , Text2 Chn. Nr.:25
113 9 26 AL.CHANNEL Nr.:26 , Text2 Chn. Nr.:26
113 10 27 AL.CHANNEL Nr.:27 , Text2 Chn. Nr.:27
113 11 28 AL.CHANNEL Nr.:28 , Text2 Chn. Nr.:28
113 12 29 AL.CHANNEL Nr.:29 , Text2 Chn. Nr.:29
113 13 30 AL.CHANNEL Nr.:30 , Text2 Chn. Nr.:30
113 14 31 AL.CHANNEL Nr.:31 , Text2 Chn. Nr.:31
113 15 32 AL.CHANNEL Nr.:32 , Text2 Chn. Nr.:32
114 0 33 AL.CHANNEL Nr.:33 , Text2 Chn. Nr.:33
114 1 34 AL.CHANNEL Nr.:34 , Text2 Chn. Nr.:34
114 2 35 AL.CHANNEL Nr.:35 , Text2 Chn. Nr.:35
114 3 36 AL.CHANNEL Nr.:36 , Text2 Chn. Nr.:36
114 4 37 AL.CHANNEL Nr.:37 , Text2 Chn. Nr.:37
114 5 38 AL.CHANNEL Nr.:38 , Text2 Chn. Nr.:38
114 6 39 AL.CHANNEL Nr.:39 , Text2 Chn. Nr.:39
114 7 40 AL.CHANNEL Nr.:40 , Text2 Chn. Nr.:40

Page: 7
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label9
Reg.Addr. Bit Alarm No. Alarm Function
114 8 41 AL.CHANNEL Nr.:41 , Text2 Chn. Nr.:41
114 9 42 AL.CHANNEL Nr.:42 , Text2 Chn. Nr.:42
114 10 43 AL.CHANNEL Nr.:43 , Text2 Chn. Nr.:43
114 11 44 AL.CHANNEL Nr.:44 , Text2 Chn. Nr.:44
114 12 45 AL.CHANNEL Nr.:45 , Text2 Chn. Nr.:45
114 13 46 AL.CHANNEL Nr.:46 , Text2 Chn. Nr.:46
114 14 47 AL.CHANNEL Nr.:47 , Text2 Chn. Nr.:47
114 15 48 AL.CHANNEL Nr.:48 , Text2 Chn. Nr.:48
115 0 49 AL.CHANNEL Nr.:49 , Text2 Chn. Nr.:49
115 1 50 AL.CHANNEL Nr.:50 , Text2 Chn. Nr.:50
115 2 51 AL.CHANNEL Nr.:51 , Text2 Chn. Nr.:51
115 3 52 AL.CHANNEL Nr.:52 , Text2 Chn. Nr.:52
115 4 53 AL.CHANNEL Nr.:53 , Text2 Chn. Nr.:53
115 5 54 AL.CHANNEL Nr.:54 , Text2 Chn. Nr.:54
115 6 55 AL.CHANNEL Nr.:55 , Text2 Chn. Nr.:55
115 7 56 AL.CHANNEL Nr.:56 , Text2 Chn. Nr.:56
115 8 57 AL.CHANNEL Nr.:57 , Text2 Chn. Nr.:57
115 9 58 AL.CHANNEL Nr.:58 , Text2 Chn. Nr.:58
115 10 59 AL.CHANNEL Nr.:59 , Text2 Chn. Nr.:59
115 11 60 AL.CHANNEL Nr.:60 , Text2 Chn. Nr.:60
115 12 61 AL.CHANNEL Nr.:61 , Text2 Chn. Nr.:61
115 13 62 AL.CHANNEL Nr.:62 , Text2 Chn. Nr.:62
115 14 63 AL.CHANNEL Nr.:63 , Text2 Chn. Nr.:63
115 15 64 AL.CHANNEL Nr.:64 , Text2 Chn. Nr.:64
116 0 65 AL.CHANNEL Nr.:65 , Text2 Chn. Nr.:65
116 1 66 AL.CHANNEL Nr.:66 , Text2 Chn. Nr.:66
116 2 67 AL.CHANNEL Nr.:67 , Text2 Chn. Nr.:67
116 3 68 AL.CHANNEL Nr.:68 , Text2 Chn. Nr.:68
116 4 69 AL.CHANNEL Nr.:69 , Text2 Chn. Nr.:69
116 5 70 AL.CHANNEL Nr.:70 , Text2 Chn. Nr.:70
116 6 71 AL.CHANNEL Nr.:71 , Text2 Chn. Nr.:71
116 7 72 AL.CHANNEL Nr.:72 , Text2 Chn. Nr.:72
116 8 73 AL.CHANNEL Nr.:73 , Text2 Chn. Nr.:73
116 9 74 AL.CHANNEL Nr.:74 , Text2 Chn. Nr.:74
116 10 75 AL.CHANNEL Nr.:75 , Text2 Chn. Nr.:75
116 11 76 AL.CHANNEL Nr.:76 , Text2 Chn. Nr.:76
116 12 77 AL.CHANNEL Nr.:77 , Text2 Chn. Nr.:77
116 13 78 AL.CHANNEL Nr.:78 , Text2 Chn. Nr.:78
116 14 79 AL.CHANNEL Nr.:79 , Text2 Chn. Nr.:79

Page: 8
Project: Project1 Device name: Device1 Date: 25.2.2025
Serial no.: 2993 Extended board: none Type: Y:F1
Customer: Prepared by:
Device description: Project description:

label10
label11

Reg.Addr. Function Data value Unit


0 No command x (don't care) -
1 Acknowledge x -
2 Diesel start order x -
3 Diesel start next order x -
4 Diesel stop order x Decimal value - Op. mode
5 Diesel stop next order x 0: Local, 1: Remote, 2: SCADA, 3: test local, 4: test remote
6 Set operation mode 0: Manual, 1: Automatic -
7 Set breaker operating mode see right -
8 Reset temp. power counter x -
9..19 Not in use - -
20 Priority of generator 1-14 -
21 Asym. load sharing setpoint 0 - 200 % of kW
22 Asym. PF controller setpoint 0 - 100 80 = PF 0.8
947 Freq. controller idle speed 0 - 9999 5000 = 50.00Hz
948 Freq. controller full load 0 - 9999 5000 = 50.00Hz
23 New time year 2003-2040 -
24 New time month 1-12 -
25 New time day 1-31 -
26 New time hour 0-23 -
27 New time minute 0-59 -
28 New time second 0-59 -
29 New time millisecond 0-999 -

Reg.Addr. Data value SYMAP Event Function


30 0:R 1:S 330 Modbus FC06 Reg. Addr. 30
31 0:R 1:S 331 Modbus FC06 Reg. Addr. 31
32 0:R 1:S 332 Modbus FC06 Reg. Addr. 32
33 0:R 1:S 333 Modbus FC06 Reg. Addr. 33
34 0:R 1:S 334 Modbus FC06 Reg. Addr. 34
35 0:R 1:S 335 Modbus FC06 Reg. Addr. 35
36 0:R 1:S 336 Modbus FC06 Reg. Addr. 36
37 0:R 1:S 337 Modbus FC06 Reg. Addr. 37
38 0:R 1:S 338 Modbus FC06 Reg. Addr. 38
39 0:R 1:S 339 Modbus FC06 Reg. Addr. 39
40 0:R 1:S 340 Modbus FC06 Reg. Addr. 40
41 0:R 1:S 341 Modbus FC06 Reg. Addr. 41
42 0:R 1:S 342 Modbus FC06 Reg. Addr. 42
43 0:R 1:S 343 Modbus FC06 Reg. Addr. 43
44 0:R 1:S 344 Modbus FC06 Reg. Addr. 44
45 0:R 1:S 345 Modbus FC06 Reg. Addr. 45
46 0:R 1:S 346 Modbus FC06 Reg. Addr. 46
47 0:R 1:S 347 Modbus FC06 Reg. Addr. 47
48 0:R 1:S 348 Modbus FC06 Reg. Addr. 48
49 0:R 1:S 349 Modbus FC06 Reg. Addr. 49