0% found this document useful (0 votes)
8 views204 pages

Sistemas Línea Simple

The SKF lubrication systems catalog provides an overview of various lubrication solutions, including single-line systems for oil and grease, pumps, metering devices, control units, and sensors. It emphasizes the importance of proper lubrication for reducing wear and improving machine reliability across various industries. The catalog also highlights the advantages of SKF's systems, such as ease of installation, adaptability, and the ability to operate under diverse conditions.

Uploaded by

francisco83461
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views204 pages

Sistemas Línea Simple

The SKF lubrication systems catalog provides an overview of various lubrication solutions, including single-line systems for oil and grease, pumps, metering devices, control units, and sensors. It emphasizes the importance of proper lubrication for reducing wear and improving machine reliability across various industries. The catalog also highlights the advantages of SKF's systems, such as ease of installation, adaptability, and the ability to operate under diverse conditions.

Uploaded by

francisco83461
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 204

Single-line

lubrication systems
Product catalogue
SKF lubrication systems catalogues
Introduction

PUB LS/P1 17046 EN PUB LS/P1 16132 EN PUB LS/P1 17478 EN PUB LS/P1 16964 EN

PUB LS/P1 18000 EN PUB LS/P1 15859 EN

2
Navigation

Introduction 2

Introduction
Pumps and pump units for oil 13

Pumps and pump units for grease 49

Metering devices for oil 89

Metering devices for grease 127

Control units 147

Pressure sensors 169

Flow monitors and sensors 187

Solenoid valves 191

3
Table of contents

Two leading brands 6 83599 62


Lubricants suitable for lubrication systems 7 HG 1000, HG 2000 63
Introduction

Single-line lubrication systems for oil and fluid grease 8 84944, 84961 64
Single-line lubrication systems for grease 10 84960, 84962 65
MPB 66
Overview of oil and fluid grease pumps and pump units 13 84050, 85460 68
1812 14 282288 69
POE 15 FlowMaster, hydraulic 70
PFE 16 P 603S 72
283167 17 Minilube 74
82885, 83667 18 KFG 76
85438/40/41 19 Multilube MLPV / MLPI 78
P / PW / PF / PFW-289 20 P 653S 80
POEP 22 E-PUMP 82
PFEP 23 FK 84
PPS30 24 FlowMaster, electric 86
82676 26
82570 27 Overview of oil and fluid grease metering devices 89
85430/31/32/33 28 341 90
PEF / PEU 29 340 92
1826 30 LS22 94
ECP 32 LS21 95
P 653S (oil) 34 361 96
KFB 36 310 98
KFB-M 38 351 100
KFU 40 350 102
MKU 42 370 104
MKF 44 391 106
MFE 46 Manifold 107
390 108
Overview of grease pumps and pump units 49 321 G, T, W, G4, Module, G7 110
83817 52 AB 112
1810 53 VN 114
40PGA 54 OI-AL-SR 116
82886, 83668 56 SL-42 118
85442 57 SL-43 120
85444/45 58 SL-41 122
85434/35/36 59 SL-44 124
82653/55, 83800/34 60
83167 61

4
Table of contents

Overview of grease metering devices 127 Overview of pressure sensors 169


SL-33 128 DSA 170

Introduction
B-doser 130 DSD 172
LG-doser 132 DSB1 174
SL-32HV 134 69630 176
SL-1 135 234-10825-8 177
QSL 136 DSC2 178
VR 138 DSC3 179
SLC 140 234-11145-3, -4, -5, -9 180
SL-11 142 234-10330-4 181
SL-V 143 234-13161- 182
SL-V XL 144 234-11272-4 183
DSC1 184
Overview of control units 147 247333 185
EXZT / IGZ 148
IG502-2-E 150 Overview of flow monitors and sensors 187
LC502 151 GS304P 188
ST-2240-LUB 152 HCC 189
ST-1240 153
ST-1100i 154 Overview of solenoid valves 191
ST-102 155 35024 192
ST-102P 156 350282, 350283 193
84501 157 253-14076-X 194
84015 158 525-320 -1 195
85520 159 161-110-031 196
85525 160 161-140-050 197
LMC 101 161
EOT-1/2 664-34135-6, 664-34135-7 162 Index 198
LMC 2 163
LMC 301 164
LRM 2 166

5
Two leading brands
Introduction

One global leader


SKF and Lincoln have joined forces to provide you with the world’s Both SKF and Lincoln systems are available through our global net-
most complete portfolio of innovative lubrication solutions – from work of lubrication experts, offering you world-class installation and
manual lubricators and tools, to the most advanced centralized and ongoing support on a local level – today and into the future With the
automatic lubrication systems available power of this network, and more than 200 years of combined friction
In addition to traditional lubrication products and systems, we offer management experience, we can help you improve machine reliabil-
customized solutions for many industries such as pulp and paper, ity, reduce maintenance, increase productivity, enhance safety and
steel, mining, agriculture, marine, rail, wind, construction, machine optimise manpower resources
tool and automotive SKF engineering and technical specialists part-
ner with OEMs and end-users to develop system solutions based on
customer requirements We also offer a variety of control and
monitoring equipment for ease of use and to help ensure
proper lubrication

6
Lubricants suitable for lubrication systems

fluid semi-fluid non-fluid

Introduction
Oil Fluid Grease
grease

ISO VG 3 10 32 100 320 680 1 500 2 200 3 200


NLGI grades 000 00 0 1 2 3 4

Oil and fluid grease


The viscosity is an expression of a fluid’s internal friction Oils are
classified in ISO VG viscosity classes from 2 to 3 200 NLGI grade 000, 00 and 0 greases
are called fluid greases Different types of oils are available, including mineral oils, organic
oils and synthetic oils A compatibility check is recommended prior to using any oil with
SKF lubrication systems

Grease
Greases are consistent lubricants (NLGI grade 1–6) They are soft to hard, triple-compo-
nent mixtures of a base oil as the lubricating fluid, a thickening agent and additives
In most instances, greases of NLGI grade 1 up to 3 are suitable for use in a lubrication
system A compatibility check should be made prior to using any grease with
SKF lubrication systems

7
Single-line lubrication systems for oil and fluid grease

System video
Introduction

System description
Regardless of the application, the principle of single-line lubrication SKF application engineers, as well as SKF sales partners
remains the same: a central pump station automatically delivers and distributors, are experts in laying out lubrication systems
lubricant through a single supply line to the lubricant metering according to all these specifications A lubrication system laid out by
device Each metering device serves only one lubrication point and SKF and partners ensures the supply of the correct amount of lubri-
may be adjusted to deliver the precise amount of grease or oil cant at the best time to lubricate This reduces wear and avoids pol-
required Systems can service one machine, different zones on one lution caused by over-lubrication
machine or even several separate machines The SKF portfolio
includes both SKF MonoFlex and Lincoln Centro-Matic system com-
Advantages:
ponents including pumps, metering units, control and monitoring
devices and accessories • Easy to understand, install and maintain
For planning a lubrication system, conditions the system will be used • Available in both preset and adjustable models
in need to be determined first The number of lubrication points, • Suitable for almost all lubricants
back pressures at the lubrication points, operating temperature
range, lubricant, the feed pump’s drive energy, control and monitor- • Easy system expansion
ing etc need to be defined correctly Attention to information on • System continues to operate if one point becomes blocked
bearing or lubrication point information need to be paid too The sum • Integrated system control and monitoring
of all the quantities metered out by the system’s metering devices
needs to be completed by safety margin and expansion and com- • Able to pump long distances and within a wide
pressibility loss temperature range

8
Introduction
Applications
In total loss lubrication systems, fresh lubricant is fed to friction • Small-to-medium line length
points during a lubrication cycle The lubrication cycle is set up so • Small-to-medium quantities of
that friction points are supplied with enough lubricant to build up an
adequate film of lubricant, reducing wear and tear on bearings and • lubricant per lubrication point
friction points. Monoflex and Centromatic systems are designed to • Ease of expansion
allow for easy expansion and simple assembly. • Linear layout of lubrication points
Applications for single-line systems include small-to-medium • Flexibility of lubricant distribution
machine tools, mobile on-road (fleet vehicles, on-road transport),
and assembly/automation food packaging, part assembly lines and • Easy monitoring of lubrication distribution
injection molding:

9
Single-line lubrication systems for grease

System video
Introduction

System description
Regardless of the application, the principle of single-line lubrication SKF application engineers, as well as SKF sales partners and
remains the same: a central pump station automatically delivers distributors, are experts in laying out lubrication systems according
lubricant through a single supply line to the lubricant metering to all these specifications. A lubrication system laid out by SKF and
device. Each metering device serves only one lubrication point and partners ensures the supply of the correct amount of lubricant at
may be adjusted to deliver the precise amount of grease or oil the best time to lubricate. This reduces wear and it avoids pollution
required. Systems can service one machine, different zones on one caused by over-lubrication.
machine or even several separate machines. All single-line systems
include a pump, injectors, controller and a pressure switch /trans-
Advantages:
ducer. These components are very easy to install and modify on
any application as needed. • Easy to understand, install and maintain
SKF offers two brands of single line parallel lubrication systems: • Fully adjustable or customizable for any application
the Lincoln Centro-Matic and the SKF MonoFlex. These systems are • Suitable for almost all lubricants
recognized world wide for their reliability to lubricate in adverse
conditions in virtually any application. For planning a lubrication • Simple system expansion
system, conditions the system will be used in need to be determined • System continues to operate if one point becomes blocked
first. The number of lubrication points, back pressures at the lubrica- • Integrated system control and monitoring
tion points, operating temperature range, lubricant, the feed pump’s
drive energy, control and monitoring etc. need to be defined correctly. • Able to pump long distances within a wide temperature range

Attention to information on bearing or lubrication point specifications


need to be paid too. The sum of all the quantities metered out by the
system’s metering devices needs to be completed by safety margin
and compressibility loss.

10
Introduction
Applications
Mining applications have been installed in the far north including the
Oil Sands of Canada and Siberia and in the hot deserts of Africa and
Australia. Major food, beverage, oil/gas, cement, steel, construction
and rail customers also rely on SKF’s single-line products. Single-
line applications benefit from SKF’s method of delivering precise
amounts of lubricant at controlled intervals to the lubrication point.

• Mining
• On/Off-road
• Construction machinery
• Cement industry
• Food and beverage
• Machine tools
• Railroad
• Forestry
• Steel
• And more

11
Pump units for oil

12
Overview of oil and fluid grease pumps and pump units

Pump units for oil


Manually operated pump units

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Page
max. category 1)

oil fluid grease cm3/stroke in3/stroke bar psi l gal 1 2 3 4

1812 • • 2,6 0.16 69 1 000 2,1 0.55 – ● ● ● 14


POE • – 15 0.9 30 435 0,5; 1; 1,7 0.13; 0.26; 0.45 ● ● – – 15
PFE – • 15 0.9 30 435 0,5; 1; 1,7 0.13; 0.26; 0.45 ● ● – – 16
1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range

Air-operated pumps and pump units

Product Lubricant Metering quantity Operating Reservoir Metering device Page


max pressure category 1)

oil fluid grease cm3/stroke in3/stroke bar psi l gal 1 2 3 4

283167 • • 1,97 0.12 69 1 000 7,1 1.88 – – ● ● 17


82885, 83667 • • 7,4 0.45 69 1 000 0,6; 2 0.16; 0.53 – ● ● ● 18
85438 / 40 / 41 2) • • 7,4 0.45 69 1 000 0,6; 2 0.16; 0.53 – ● ● ● 19
P/PW/PF/PFW-289 • • 10 0.61 40 580 1,5 0.39 ● ● ● – 20
POEP • – 15 0.9 60 870 0,5; 1; 1,7 0.13; 0.26; 0.45 ● ● ● ● 22
PFEP – • 15 0.9 60 870 0,5; 1; 1,7 0.13; 0.26; 0.45 ● ● ● ● 23
PPS30 • • 30 1.83 27 392 1,5 0.39 ● ● – – 24
82676 • • 39,3 2.39 69 1 000 – – – – – ● 26
82570 • • 39,3 2.39 69 1 000 2 0.53 – – – ● 27
85430 / 31 / 32 / 33 2) • • 39,3 2.39 69 1 000 0,0; 2 0.0; 0.53 – – – ● 28
PEF/PEU • • 48 2.93 50 725 3 0.79 ● ● ● – 29

1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller optionally

Air-operated barrel pumps

Product Lubricant Metering quantity Operating Reservoir Metering device Page


max pressure category 1)

oil fluid grease cm3/min in3/min bar psi l gal 1 2 3 4

1826 2) • • 7 571 462 69 1 000 200 52.83 – ● ● ● 30


1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller optionally

Electrically operated pumps and pump units

Product Lubricant Metering quantity Operating Reservoir Metering device Page


max pressure category 1)

oil fluid grease cm3/min in3/min bar psi l gal 1 2 3 4

ECP • • 12 0.73 38 550 0,38 0.086 ● ● ● – 32


P653S (oil) 2) 3) • • 24,6 1.5 240 3500 4; 8 1.05; 2.11 – ● ● ● 34
KFB 2) • • 50 3 38 550 1 0.26 ● ● ● – 36
KFB-M 2) • • 50 3 38 550 1 0.26 ● ● ● – 38
KFU • • 140 8.5 38 550 2,7; 6 0.71; 1.56 ● ● ● – 40
MKU 2) • – 100; 200; 500 6; 12; 31 30 435 2; 3; 6 0.53; 0.79; 1.56 ● – – – 42
MKF 2) • • 100; 200; 500 6; 12; 31 30 435 2; 3; 6 0.53; 0.79; 1.56 ● ● – – 44
MFE • • 250; 500 15; 31 28 405 3; 6; 15 0.79; 1.56; 3.96 ● ● – – 46
1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller optionally
3) With pressure transducer

13
Pump unit

1812
Pump units for oil

Description
Technical data
The 1812 pump features a translucent reservoir with filler cap and
Order number 1812
strainer Its pump base has an integrated check/vent valve and an
indicator pin to show when system pressure is achieved Function priciple manually operated piston pump
Outlets 1
Metering quantity 2,6 cm 3/ stroke , 0.16 in 3/ stroke
Feature and benefits Lubricant oil, synthetic oil on request
Operating temperature –23 to +65 °C
• Provides precise lubrication where air –10 to +150 °F
Operating pressure max 70 bar, 1 000 psi
or electricity are not available Reservoir 2,13 l; 2 130 cm 3
0.5 gal, 130 in 3
• Built-in vent valve activates when handle Material (reservoir) acrylic
is pushed all the way up Connection outlet 1/4 NPTF (F)
Dimensions 425 × 181 × 197 mm
• Pressure stem indicates 58 bar; 850 psi 16.75 × 7.125 × 7.75 in
Mounting position vertical
• Suitable for use with metering devices of category 2, 3, 4

Applications
• Textile
• Stationary
• Material handling including presses
• Agriculture and farming

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

14
Pump unit

POE

Pump units for oil


Description
Technical data
These manually actuated plunger pumps were developed for inter-
Function priciple manually operated piston pump
mittently operated, single-line centralized lubrication systems with Outlets 1
metering devices They include a set of valves required for pressure Metering quantity 15 cm 3/ stroke, 0.9 in 3/ stroke
relief and pressure limitation Versions are available with or without Lubricant mineral, synthetic, and environmentally
compatible oils, operating viscosity
fill-level switches to monitor critical levels of lubricant, and reservoirs 20 to 1 500 mm 2/ s
are offered in three different sizes Operating temperature 0 to +60 °C; +32 to +140 °F
Operating pressure max 30 bar, 435 psi
Reservoir 0,5; 1,0 or 1,7 l, 0.1, 0.3 or 0.4 gal
Feature and benefits Material (reservoir) plastic (PP), transparent
Connection outlet G 1/4, on left or right
• Suitable for amount of lube points per stroke: Dimensions depending on model
min 133 × 248 × 124 mm
– 1-20: metering device 340 max 190 × 448 × 124 mm
– 1-18: metering device 350 min. 5.2 × 9.8 × 4.8 in
– 1-6: metering device 390 max. 7.5 × 17.6 × 4.8 in
Mounting position vertical
• Simple handling
Fill-level switch for monitoring the minimum oil level
• Low-cost, efficient method of distributing lubricant Type of contact contact opens at minimum fill level
• Optional low-level control for resevoir Switching voltage max 42 V DC
Switching capacity max 50 W
• Suitable for use with metering devices of category 1 Plug 4-pin M 12x1 circular plug
Mounting position 1, 2 or 3 possible (2 on delivery)

Applications
• Machine tool
• Industrial assembly and automation

Order information NOTE


Order number Reservoir Fill-level switch Further technical information, technical drawings,
l gal accessories, spare parts or product function descriptions
available on SKF com/lubrication:
POE-15-0 5 0,5 0.13 – 1-1110-EN, 951-170-011 EN
POE-15-1 0 1,0 0.26 –
POE-15-1 0W 1,0 0.26 • 3D
POE-15-1 7 1,7 0.45 – skf-lubrication partcommunity com/3d-cad-models
POE-15-1 7W 1,7 0.45 •

15
Pump unit

PFE
Pump units for oil

Description
Technical data
These manually actuated plunger pumps were developed for inter-
Function principle manually operated piston pump
mittently operated, single-line centralized lubrication systems with Outlets 1
metering devices They include a set of valves required for pressure Metering quantity 15 cm 3/ stroke, 0.9 in 3/ stroke
relief and pressure limitation Versions are available with or without Lubricant fluid grease, NLGI 000, 00
Operating temperature 0 to +60 °C; +32 to +140 °F
fill-level switches to monitor critical levels of lubricant, and reservoirs
are offered in three different sizes Operating pressure max 30 bar, 435 psi
Reservoir 0,5; 1,0 or 1,7 l, 0.1, 0.3 or 0.4 gal
Material (reservoir) plastic (PP), transparent
Feature and benefits Connection outlet G 1/4, on left or right
Dimensions depending on model
min 133 × 248 × 124 mm
• Simple handling
max 190 × 448 × 124 mm
• Low-cost, efficient method of distributing lubricant min. 5.2 × 9.8 × 4.8 in
max. 7.5 × 17.6 × 4.8 in
• Optional low-level control for reservoir Mounting position vertical

• Suitable for use with metering devices of category 1 and 2 Fill-level switch for monitoring the minimum grease level
Type of contact NPN, PNP/NO-contact - NC contact
Switching voltage 10 to 36 V DC
Applications Current at switching output max 150 mA
Protection class IP 67
Connection 2 m PVC cable or 4-pin M8x1 circular plug
• Machine tool
Mounting position 1, 2 or 3 possible (2 on delivery)
• Printing machines
• Industrial assembly and automation

Order information NOTE


Order number Reservoir Fill-level switch Further technical information, technical drawings,
l gal accessories, spare parts or product function descriptions
available on SKF com/lubrication:
PFE-15-0 5 0,5 0.13 – 1-1110-EN, 951-170-011 EN
PFE-15-1 0 1,0 0.26 –
PFE-15-1 0W2 1,0 0.26 • 3D
PFE-15-1 7 1,7 0.45 – skf-lubrication partcommunity com/3d-cad-models
PFE-15-1 7W2 1,7 0.45 •

16
Pump unit

283167

Pump units for oil


Description
Technical data
Pump model 283167 includes air motor, vent valve, translucent
Order number 283167
reservoir with filler cap, strainer and 1 200 psi (82 bar) safety
unloader Pump is an oscillating positive displacement pump Function principle air, reciprocating piston pump
with pneumatic drive The change-over valve of the pump drive Outlets 1
Metering quantity 1,97 cm 3/ stroke, 0 12 in 3/ min
controls reciprocating of the pump strokes (discharges oil to outlet Working frequency max 100 cycles/min
on forward stroke and sucks oil on back stroke) The reciprocating Lubricant oil, synthetic oils on request
pump operates under air pressure and as such discharges material Operating temperature -23 to +65 °C
-10 to +150 °F
until the required system oil pressure is built up The shut off and Operating pressure max 70 bar, 1 000 psi
monitoring of the pump must be initiated by a pressure switch, Reservoir 7,1 l, 7 100 cm 3, 1.8 gal, 433 in 3
3/2 way air valve, components to limit and adjust the air operating Material (reservoir) acrylic
Air inlet connection 1/8 NPTF (F)
pressure These parts are to be furnished on site of the user Connection outlet 3/4 NPTF (F)
Transmission ratio 40:1
Air valve required, 3-way
Features and benefits Dimensions 591 × 229 × 413 mm
23.25 × 9 × 16.25 in
• Reservoir with filler cap and internal strainer Mounting position vertical

• Vent valve assembly enclosed


• Remote system components available upon request
• Suitable for use with metering devices of category 3 and 4

Applications Note:
When operating the pump with air pressure > 1,7 bar a pressure switch for oil is required
to limit the oil pressure (max 68 bar) of the central lubrication system
• Steel mills
• Glass manufacturing plants
NOTE
• Packaging
Further technical information, technical drawings,
• Plastic processing accessories, spare parts or product function descriptions
• Material handling available on SKF com/lubrication
• Food and beverage
• Metal cutting, metal forming
• Systems with many lubrication points

17
Pump unit

82885, 83667
Pump units for oil

Description
Technical data
Model 82885, an air-operated, single-stroke oil pump, discharges
lubricant on an air-powered forward stroke and releases pressure Function principle air operated piston pump
Outlets 1
on the lubricant line on a spring-powered return stroke through an Metering quantity 7,4 cm 3/ stroke, 0.45 in 3/ stroke
integrated check/relief valve (3 way) Its translucent reservoir is Working frequency
Lubricant oil, synthetic oils on request
refilled through a filler cap with strainer The pump unit is suitable for
Operating temperature –23 to +65 °C
systems with a large number of lubrication points and clocked greas- –10 to +150 °F
ing strokes Model 83667 offers the same features but Operating pressure max 70 bar, 1 000 psi
Reservoir 0,6 and 2,0 l; 0.16 and 0.5 gal
includes a larger reservoir Material (reservoir) acrylic
Connection outlet 1/4 NPTF (F)
Feature and benefits Air inlet connection 1/4 NPTF (F)
Transmission ratio 20:1
• Reliable operation Air valve required, 3-way
Dimensions min 263 × 133 × 152 mm
• Reservoir with filler cap and internal strainer max 470 × 140 × 152 mm
• Suitable for use with metering devices of category 2, 3 and 4 min. 10.375 × 5.25 × 6 in
max. 18.5 × 5.5 × 6 in
Mounting position vertical
Applications
• Textiles
• Steel mills
• Packaging
• Plastic processing
• Material handling
• Food and beverage

Order information NOTE


Further technical information, technical drawings,
Order number Reservoir
accessories, spare parts or product function descriptions
l gal available on SKF com/lubrication:
442832
82885 0,6 0.16
83667 2,0 0.5 3D
skf-lubrication partcommunity com/3d-cad-models

18
Pump unit

85438/40/41

Pump units for oil


Description
Technical data
Pump models 85438/40/41 are air-operated, positive
displacement pumps that deliver a maximum volume by means Function principle air operated piston pump
of a single stroke of the pump Solenoid air valve and adjustable (single stroke)
Outlets 1
solid-state time controls are integrated into the pump body Metering quantity 7,4 cm 3/ stroke; 0.45 in 3/ stroke
These pumps are designed to deliver fluid lubricants to single-line Working frequency
Lubricant oil, synthetic oils on request
injectors and are filled via a spring-loaded filler cap and internal Operating temperature –23 to +65 °C
strainer Acrylic reservoirs are available in two sizes Supply –10 to +150 °F
voltages are offered in 120 V AC and 240 V AC Operating pressure max 70 bar, 1 000 psi
Reservoir
85438 0,6 l; 0.16 gal
Features and benefits 85440, 85441 2,0 l; 0.5 gal
Material (reservoir) acrylic
• Reservoir with filler cap and internal strainer Connection outlet 1/4 NPTF (F)
• Integrated, adjustable, solid-state time controls with LED Voltage 120 V AC, 240 V AC
indicators for “Power On,” “Pump On” and “Alarm,” along with Transmission ratio 20:1
Dimensions:
a membrane-type “Manual Lube” switch 85438 133 × 184 × 305 mm
• Integrated solenoid air valve 5.25 × 7.24 × 12.02 in
• Suitable for use with metering devices of category 2, 3 and 4 85440, 85441 133 × 184 × 527 mm
5.25 × 7.24 × 20.75 in
Mounting position vertical
Applications
Timer and controller
• Textiles On time 10 or 30 sec
• Steel mills Off time 30 sec to 30 min or 30 min to 30 h
• Plastic processing Alarm contacts 8 A at 250 V AC
Operating temperature –23 to 65 °C; –10 to +150 °F
• Material handling
• Food and beverage

Order information NOTE


Further technical information, technical drawings,
Order number Voltage Reservoir
accessories, spare parts or product function descriptions
V AC l gal available on SKF com/lubrication:
442832
85438 120 0,6 0.16
85440 120 2,0 0.5 3D
85441 240 2,0 0.5 skf-lubrication partcommunity com/3d-cad-models

19
Pump unit

P / PW / PF / PFW-289
Pump units for oil

Description
Technical data
These pneumatically actuated piston pumps were designed for
Function principle air operated piston pump
intermittently operated, single-line centralized lubrication systems (single stroke)
with metering devices The valve set required for pressure relief and Outlets 1
limitation is included Metering quantity 10 cm 3/ stroke, 0.61 in 3/ stroke
Working frequency
Lubricant mineral, synthetic, and environmentally
friednly oils, operating viscosity 20 to
Features and benefits 1 500 mm 2/ s or fluid grease with
NLGI 000, 00
• Electrical monitoring via external controller or SPS Operating temperature +10 to +40 °C; +50 to +104 °F
Operating pressure max 40 bar, 580 psi
• Simple handling Reservoir 1,5 l, 0.4 gal
• Optional low-level control for reservoir Material (reservoir) polycarbonate
Connection outlet 6 mm, 0.24 in, OD tube
• Suitable for use with metering devices of category 1, 2 and 3 Dimensions depending on model
min 170 × 248 × 128 mm
max 170 × 270 × 128 mm
min. 6.7 × 9.8 × 5.04 in
Applications max. 6.7 × 10.6 × 5.04 in
Mounting position vertical
• Machine tool
Fill-level switch for monitoring the minimum fluid grease level
• Printing machines Type of contact 1 change-over
• Industrial assembly and automation Switching voltage 230 V AC; 230 V DC
Switching current max 230 V AC/DC: 1,0 A
Breaking capacity max 230 V AC: 60 VA;
max 230 V DC:40 W
Type of enclosure IP 65
Cable gland PG11

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1110-EN, 951-170-012
3D
skf-lubrication partcommunity com/3d-cad-models

20
Pump unit

P / PW / PF / PFW-289

Pump units for oil


Order information

Order number Lubricant Fill-level switch


Oil Fluid grease

P-289 • – –
PW-289 • – •
PF-289 – • –
PFW-289 – • •

21
Pump unit

POEP
Pump units for oil

Description
Technical data
These pneumatically actuated plunger pumps were developed for
Function principle air operated piston pump
intermittently operated, single-line centralized lubrication systems Outlet 1
with metering devices They include a set of valves required for pres- Metering quantity 15 cm 3/ stroke, 0.9 in 3/ stroke
sure relief and pressure limitation Versions are available with or Working frequency
Lubricant mineral, synthetic oils, operating
without fill-level switches to monitor critical levels of lubricant viscosity 20 to 1 500 mm 2/ s
Operating temperature 0 to +60 °C; +32 to +140 °F
Operating pressure max 60 bar, 870 psi
Features and benefits Reservoir 0,5; 1,0 or 1,7 l, 0.13, 0.26 or 0.45 gal
Material (reservoir) plastic (PP), transparent
• Electrical monitoring via external controller or SPS Connection outlet G 1/4, on left or right
Air inlet G 1/4 (on pump bottom)
• Simple handling Transmission ratio 10:1
Dimensions depending on model
• Low-cost, efficient method of distributing lubricant min 133 × 248 × 124 mm
max 190 × 448 × 124 mm
• Optional low-level control for reservoir min. 5.2 × 9.8 × 4.8 in
• Suitable for use with metering devices of category 1, 2, 3 and 4 max. 7.5 × 17.6 × 4.8 in
Mounting position vertical

Fill-level switch for monitoring the minimum oil level


Applications Type of contact contact opens at minimum fill level
Switching voltage max 42 V DC
• Machine tool Switching capacity max 50 W
Plug 4-pin M 12 × 1 circular plug
• Printing machines Mounting position 1, 2 or 3 possible (2 on delivery)
• Industrial assembly and automation Note:
For a hydraulic system pressure of >45 bar, 653 psi, use cutting-sleeve screw unions
conforming to DIN 2353 or plug connectors as connection fittings

Order information NOTE


Order number Reservoir Fill-level switch Further technical information, technical drawings,
l gal accessories, spare parts or product function descriptions
available on SKF com/lubrication:
POEP-15-0 5 0,5 0.13 – 1-1110-EN, 951-170-011 EN
POEP-15-1 0 1,0 0.26 –
POEP-15-1 0W 1,0 0.26 • 3D
POEP-15-1 7 1,7 0.45 – skf-lubrication partcommunity com/3d-cad-models
POEP-15-1 7W 1,7 0.45 •

22
Pump unit

PFEP

Pump units for oil


Description
Technical data
These pneumatically actuated plunger pumps were developed for
Function principle air operated piston pump
intermittently operated, single-line centralized lubrication systems Outlets 1
with metering devices They include a set of valves required for pres- Metering quantity 15 cm 3/ stroke, 0.9 in 3/ stroke
sure relief and pressure limitation Versions are available with or Working frequency
Lubricant fluid grease, NLGI 000, 00
without fill-level switches to monitor critical levels of lubricant Operating temperature 0 to +60 °C; +32 to +140 °F
Operating pressure max 60 bar, 870 psi
Reservoir 0,5; 1,0 or 1,7 l, 0.13, 0.26 or 0.45 gal
Features and benefits Material (reservoir) plastic (PP), transparent
Connection outlet G 1/4, on left or right
• Simple handling Air inlet G 1/4 (on pump bottom)
Transmission ratio 10:1
• Optional low-level control for reservoir Dimensions depending on model
min 133 × 248 × 124 mm
• Suitable for use with metering devices of category 1, 2, 3 and 4 max 190 × 448 × 124 mm
min. 5.2 × 9.8 × 4.8 in
max. 7.5 × 17.6 × 4.8 in
Applications Mounting position vertical

• Machine tool Fill-level switch for monitoring the minimum filling level
Type of contact NPN, PNP/NO-contact - NC contact
• Industrial assembly and automation Switching voltage 10 to 36 V DC
Current at switching output max 150 mA
Protection class IP 67
Connection 2 m PVC cable or 4-pin M8x1 circ plug

Note:
For a hydraulic system pressure of >45 bar, 653 psi, use cutting-sleeve screw unions
conforming to DIN 2353 or plug connectors as connection fittings

Order information NOTE


Order number Reservoir Fill-level switch Further technical information, technical drawings,
l gal accessories, spare parts or product function descriptions
available on SKF com/lubrication:
PFEP-15-0 5 0,5 0.13 – 1-1110-EN, 951-170-011 EN
PFEP-15-1 0 1,0 0.26 –
PFEP-15-1 0W2 1,0 0.26 • 3D
PFEP-15-1 7 1,7 0.45 – skf-lubrication partcommunity com/3d-cad-models
PFEP-15-1 7W2 1,7 0.45 •

23
Pump unit

PPS30
Pump units for oil

Description
Technical data
Setting new standards in design, this compact unit combines
proven lubrication technology with integrated functional elements Function principle air operated piston pump (single stroke)
The easy-to-clean PPS30 features an integrated relief valve and Outlets max. 3
Metering quantity 30 cm 3/ stroke, 1.83 in 3/ stroke
electronic sensors, as well as a central opening for easy filling from all Working frequency 6 strokes/h
sides In addition to low investment costs, it offers very low operating Lubricant mineral and synthetic oils,
operating viscosity 20 to 1 500 mm 2/ s
costs due to minimal compressed air consumption The lightweight or fluid grease NLGI 000, 00
unit is made almost entirely of functional, high-performance plastics Operating temperature +10 to +50 °C; +50 to +122 °F
Operating pressure max 27 bar, 392 psi
Actuation pressure 4,5 to 6 bar; 65 to 87 psi
Features and benefits Reservoir 1,5 l, 0.39 gal
Material (reservoir) plastic (SAN)
• Compact, modern design with user friendly operation
Connection outlet M 10 × 1 thread or plug connector for
• Quick and simple installation with flexible connection system pipes ø6 and ø8 mm or banjo fitting
• Easy visual fill-level monitoring plus electric fill-level control for pipe ø6 mm
Air inlet M 10 × 1 thread or plug connector for
• Suitable for use with metering devices of category 1 and 2 pipes ø6 and ø8 mm or banjo fitting
for pipe ø6 mm
Transmission ratio 4,5:1
Applications Air valve required 3-way, see accessories
• Machine tools Pressure reducting valve required, see accessories
Dimensions 187 × 246 × 129 mm
• Automation 7.3 × 9.6 × 5.1 in
• Packaging Installation space min 230 × 300 × 250 mm
• Woodworking min. 9 × 11.8 × 9.8 in
Mounting position vertical
• Printing
• Textiles
Fill-level switch for monitoring the minimum lubricant level
Function capacitive, NC-contact
Switching voltage 10 to 36 V DC
Power consumption max 150 mA
NOTE
Further technical information, technical drawings, Pressure switch for monitoring pressure build-up and function
accessories, spare parts or product function descriptions Function NO-contact
available on SKF com/lubrication: Rated pressure 16 bar, 232 psi
Electrical connection 4-pin M 12 × 1 circular plug
1-0942-EN, 951-170-220 EN
3D
skf-lubrication partcommunity com/3d-cad-models

24
Pump unit

PPS30

Pump units for oil


Identification code P P S 3 0 – 2 A

Right
Piston pump,

Rear
Left
pneumatically actuated

Lubricant
S = Oil and fluid grease

Delivery rate
30 = 30 cm 3/ stroke, 1.83 in 3/ stroke

Generation

Lubricant reservoir
1 = 1 5 l; 0 39 gal 1)
2 = 1 5 l; 0 39 gal with oil filler screen 2)
Fill level switch, min
W1 = With 1) XX = Without 2)

Pressure switch
A = 16 bar, 232 psi 1) X = Without
Electrical connection 3)
A = M 12×1 plug, 4-pin 1)
Pneumatic connection 4)
1 = Pipe thread M 10×1 3 = Banjo fitting for pipe ø 6 1) 5)
2 = Plug connector for pipe ø 6 5) 4 = Plug connector for pipe ø 8 5)
Connection main line
1 = Pipe thread M 10×1 4 = Plug connector for pipe ø 8 5)
2 = Plug connector for pipe ø 6 1) 5) X = Closed 5)
3 = Banjo fitting for pipe ø 6 5)
1) Standard design
2) The oil filler screen option can be used only on PPS30 pumps produced after September 29, 2017
3) Electrical connection required if fill-level switch and/or pressure switch is selected
4) Must select pneumatic connection
5) For fitting order numbers † accessories

Accessories
161-120- 466-421-001 506-140-VS / Order numbers for accessories
067+924 408-004-VS
Order number Designation

161-120-067+924 3/2-way air inlet valve, 24 V DC


161-120-067+910 3/2-way air inlet valve, 110 V AC
995-901-063 Pressure-reducing valve
169-400-405 Oil filler screen

Optional fittings for pneumatic and main line connections


169-400-405 995-901-063 995-901-061 406-004-VS Plug connector for pipe ø 6; order code 2
506-140-VS Banjo fitting for pipe ø 6; order code 3
408-004-VS Plug connector for pipe ø 8; order code 4
466-421-001 Closure plug; order code X
995-901-061 Adapter plate for mounting; 214 × 48 × 10 mm,
8.4 × 1.9 × 0.4 in

25
Pump unit

82676
Pump units for oil

Description
Technical data
Pump model 82676 is a high-volume pump designed for
Order number 82676
remote or bulk-fill oil applications It discharges lubricant on the
air-powered forward stroke and releases pressure on the lubricant Function principle air operated piston pump
line through included check/relief valve through a 1/2 NPTF (F) (single stroke)
Outlets 1
oil inlet (head pressure max 5,5 bar; 80 psi) Metering quantity 39,3 cm 3/ stroke, 2.4 in 3/ stroke
Working frequency
Lubricant oil, synthetic oils on request
Features and benefits Operating temperature –23 to +65 °C
–10 to +150 °F
• Designed for remote or bulk-fill oil applications Operating pressure max 70 bar, 1 000 psi
Reservoir external
• Remote system components available upon request Connection outlet 1/4 NPTF (F)
Transmission ratio 20:1
• Suitable for use with metering devices of category 4 Air valve required, 4-way
Dimensions 470 × 146 × 533 mm
18.5 × 5.75 × 21 in
Applications Mounting position vertical

• Steel mills
• Packaging
• Plastic processing
• Material handling
• Food and beverage

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

26
Pump unit

82570

Pump units for oil


Description
Technical data
Pump model 82570 is a high-volume pump that discharges
Order number 82570
lubricant on the air-powered forward stroke and releases pressure
on the lubricant line through included check/relief valve on the Function principle air operated piston pump
air-powered return stroke Its acrylic reservoir is refilled through (single stroke)
Outlets 1
the filler cap with strainer Metering quantity 39,3 cm 3/ stroke, 2.4 in 3/ stroke
Working frequency
Lubricant oil, synthetic oils on request
Features and benefits Operating temperature –23 to +65 °C
–10 to +150 °F
• Reservoir with filler cap and internal strainer Operating pressure max 70 bar, 1 000 psi
Reservoir 2,0 l, 0.5 gal
• Remote system components available upon request Reservoir material acrylic
Connection outlet 1/4 NPTF (F)
• Suitable for use with metering devices of category 2, 3 and 4 Transmission ratio 20:1
Air valve required, 4-way
Dimensions 451 × 146 × 464 mm
Applications 17.75 × 5.75 × 18.25 in
Mounting position vertical
• Textiles
• Steel mills
• Packaging
• Plastic processing
• Material handling
• Food and beverage

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

27
Pump unit

85430/31/32/33
Pump units for oil

Description
Technical data
These air-operated, positive displacement pumps deliver maximum
Function principle air operated piston pump
volume via a single stroke of the pump Solenoid air valves and (single stroke)
adjustable, solid-state time controls are integrated into the pump Outlets 1
body All pumps are designed to deliver fluid lubricants to single-line Metering quantity 39,3 cm 3/ stroke, 2 4 in 3/ stroke
Working frequency
metering devices and are filled via a spring-loaded filler cap and Lubricant oil, synthetic oils oils on request
internal filter Acrylic reservoirs are available in several sizes Operating temperature –23 to +65 °C; –10 to +150 °F
Pump models 85432 and 85433 do not include a reservoir Operating pressure max 70 bar, 1 000 psi
Reservoir 85430, 85431 only: 2 l, 0.5 gal
and are designed for remote or bulk-fill oil applications Material (reservoir) acrylic
Connection outlet 1/4 NPTF (F)
Voltage 120 V AC; 240 V AC
Features and benefits Transmission ratio 20:1
Dimensions 627 × 166 × 460 mm
• Reservoir with filler cap and internal strainer 24.7 × 5.52 × 18.11 in
Mounting position vertical
• Integrated, adjustable solid-state time controls
with LED indicators Timer and controller
• Integrated solenoid air valves On time 10 or 30 sec
Off time 30 sec to 30 min or 30 min to 30 h
• Suitable for use with metering devices of category 2, 3 and 4 Alarm contacts 8 A at 250 V AC
(85432, 85433 are only suitable for use with category 4) Operating temperature –23 to +65 °C
–10 to +150 °F

Applications
• Closing machines
• Packaging machines, material handling
• Plastic processing, tire presses

Order information NOTE


Further technical information, technical drawings,
Order number Voltage Reservoir
accessories, spare parts or product function descriptions
V AC l gal available on SKF com/lubrication

85430 120 2,0 0.5


85431 240 2,0 0.5
85432 120 – –
85433 240 – –

28
Pump unit

PEF / PEU

Pump units for oil


Description
Technical data
These pneumatically actuated piston pumps were designed for
intermittently operated, single-line centralized lubrication systems Function principle air operated piston pump
with metering devices The valve set required for pressure relief and Outlets 1
Metering quantity 48 or 50 cm 3/ stroke
limitation is included 2.93 or 3.05 in 3/ stroke
Working frequency
Lubricant mineral, synthetic, and environmentally
Features and benefits compatible oils, operating viscosity
• Driven by on-board compressed air system 20 to 1 500 mm 2/ s or fluid grease,
NLGI 000, 00
• Optional integrated control Operating temperature –25 to +80 °C; –13 to +176 °F
• Electrical monitoring via external controller or SPS Operating pressure max 50 bar, 725 psi
Reservoir 3,0 l, 0.8 gal
• Simple handling
Material (reservoir) polycarbonate
• Suitable for use with metering devices of category 1, 2 and 3 Connection outlet M 16 × 1,5
Dimensions
PEF-90 248 × 194 × 341 mm
Applications 9.8 × 7.6 × 13.4 in
• Vehicles and trailer PEF-99 W 270 × 126 × 355 mm
10.6 × 4.9 × 13.9 in
• Machine tools PEU-99 270 × 126 × 355 mm
• Printing machines 10.6 × 4.9 × 13.9 in
Mounting position vertical
• Industrial assembly and automation
Fill-level switch for monitoring the minimum grease level
Type of contact NO-contact
Order information Switching voltage max 10 to 35 V DC
Output current 400 mA
Capacity 15 mA
Order number Lubricant Fill-level switch Type of enclosure IP 54
Oil Fluid grease

PEF-90 • • •
PEF-99W – • • NOTE
PEF-99W-S1 – • • Further technical information, technical drawings,
PEF-99W-S2 – • • accessories, spare parts or product function descriptions
PEF-99W-S3 – • –
PEU-99 • • – available on SKF com/lubrication:
PEU-99-S2 • • – 1-1110-EN, 951-170-012 EN
PEU-99-S3 • – –
3D
skf-lubrication partcommunity com/3d-cad-models

29
Pump unit

1826
Pump units for oil

Description
Technical data
Pump model 1826 is modular assembled and consists of air motor,
attached pump tube, vent valve assembly, drum cover, controller, Order number 1826
lubricant connecting hoses and safety unloader Modular structured
Function principle air operated reciprocating piston pump
air motor is fully pneumatically monitored Supplied compressed air Outlets 1
to air motor moves oscillating piston in cylinder up and down Simul- Metering quantity 7 571 cm 3/ min, 462 in 3/ min
Lubricant oil
taneously outlet air pours out of opposite cylinder chamber via
exhausting baffle A signal valve operates as a sensor and forwards Pump tube 84991
pneumatic signal pressure to a relay valve as soon as piston has Volume/cycle (up and down) 100 cm 3; 6.10 in 3
Max pump cycles/minute 70 permitted
reached its fully stroke in one direction Relay valve now switches Operating temperature -34 to +93 °C
pneumatically movement of piston opposite Oscillation operation is -29 to +199 °F
working Pumps consist in two devices, air motor and pump tube Operating pressure max 70 bar; 1 000 psi
Air inlet 3/8 NPTF (F)
with integrated shovel piston Oscillation piston initiates shovel piston Connection outlet 3/4 NPTF (F)
to pump operation by sucking and pumping function Pumps are Transmission ratio 24:1
supplied in moduls must be furnished on side of user but can also Dimensions
Total length 1 464 mm; 57.64 in
supplied completely on request Immersion length 864 mm; 34.01 in
Mounting position vertical
Features and benefits
Controller
• Midsize volume PowerMaster air motor Voltage 110 V AC, 50 Hz; 120 V AC, 60 Hz
• Carbon steel pump tube with shovel-foot design,
selected fit plunger and bushing
• Vent valve assembly and safety unloader included
• Drum cover for standard U S 55 gal ( 200 l) drums
(removable head)
• Simplified, modular design
• Wear-resistant and robust construction, reliable
NOTE
• Suitable for use with metering devices of category 2, 3 and 4
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
Applications
available on SKF com/lubrication
• Steel mills
• Plastic processing
• Food and beverage
• Glass industry
• Material handling

30
31
Pump units for oil
Pump unit

ECP
Pump units for oil

Description
Technical data
The Electric Cartridge Pump ECP was developed to lubricate bear-
Function principle electrically operated piston pump
ings and linear guides in small machines It includes an integrated Outlets 2
pressure-relief This electrically driven piston pump uses 24 V DC and Metering quantity fluid grease: 12 cm 3/ min; 0.73 in 3/ min
is controlled by an external programmable logic controller (PLC) for oil: 0,012 l/min; 0.0027 gal/min
Lubricant oil: 20 to 1 500 mm 2/s
convenience In addition, the pump is capable of manually activating fluid grease: NLGI 00, 000
a lubrication cycle and can be used with an optional, integrated level Operating temperature +10 to +50 °C; +50 to +122 °F
switch to monitor the oil level of the cartridge Utilizing easy-to-ex- Operating pressure max 38 bar; 550 psi
Reservoir prefilled cartridge 380 ml; 12.8 l. oz.
change cartridges, it is compatible with oil viscosities from 20 to 1 or fixed reservoir 0,5; 1,0 or 1,7 l;
500 mm 2/ s and fluid grease grades of NLGI 00 and 000 1.06; 2.1; 3.6 pt
Outlet connection M10×1 thread or
SKF Quick Connector 6–8 mm
Operating voltage 24 V DC
Features and benefits Dimensions without cartridge:
143×172×121 mm
• Cost effective solution 5.63×6.77×4.76 in
• Simple to operate with cartridge:
307,5×172×121 mm
• Increases reliability 12.1×6.77×4.76 in
with fixed reservoir:
• Minimizes risk of using wrong or contaminated lubricant min 240×239×210 mm
min 9.45×9.40×8.27 in
• Reduces unplanned downtime max 240×439×210 mm
min 9.45×17.28×8.27 in
• Extends maintenance intervals Mounting position upright
• Minimizes environmental impact via efficient use of lubricants

Applications
• Automation NOTE
• Machine tools Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Material handling
available on SKF com/lubrication:
• Plastic processing 16966 EN, 951-170-232
• Food and beverage 3D
skf-lubrication partcommunity com/3d-cad-models

32
Pump unit

ECP

Pump units for oil


Identification code E C P 1 – 1 A –

Pump type
Electric Compact Pump

Delivery volume
1 = 10 cm3/min / 0,01 l/min

Operating pressure
1 = 38 bar

Warning switch for minimum filling level

Outlet port bottom


W = Warning level (pre-warning empty) *

Outlet port front


0 = No warning switch
Wall bracket
A = With standard bracket
0 = Without
Electric connection
A = Square plug following DIN EN 175301-803-A

Main line connection


1 = Connection thread M10x1
2 = Quick connector ∅6 mm
3 = Banjo fitting ∅6 mm
4 = Quick connector ∅8 mm
X = Closed
Cartridge or reservior version
00000 = without cartridge
F00138 = with cartridge (prefilled with Zeller+Gmelin Divinol Lithogrease 00)
1U0500 = 0,5 l * plastic refillable reservoir for oil
1U1000 = 1,0 l plastic refillable reservoir for oil
1U1700 = 1,7 l plastic refillable reservoir for oil
1F0500 = 0,5 l * plastic refillable reservoir for fluid grease (reservoir without filter)
1F1000 = 1,0 l plastic refillable reservoir for fluid grease (reservoir without filter)
1F1700 = 1,7 l plastic refillable reservoir for fluid grease (reservoir without filter)

* NOTE: The 0,5 liter version can not be ordered with warning switch and/or oil filling filter

Accessories
Pre-filled standard cartridge, 380 ml Electrical connectors

Lubricant Package Order code Rectangular connectors 179-990-033 / -147


Zeller Gmelin Divinol Lithogrease 00 10 pcs LF001/MR380 acc to DIN EN175301-803-A
Circular plug M12×1, straight 179-990-371 / -381
Main line connectors acc to DIN EN61076-2-101
Circular plug M12×1, angled 179-990-372 / -382
Connection thread M10x1 898-110-120 acc to DIN EN61076-2-101
Quick connector ∅6 mm 406-004-VS
Banjo fitting ∅6 mm 506-140-VS Wall bracket 995-901-065
Quick connector ∅8 mm 408-0074-VS Spare parts kit of gasket, adhesive 541-34901-5
Closing plug 466-431-001 Closure screw (ECP cartridge port) 541-34901-4

Pressure-relief valves 60 bar for use in main line

Pressure-relief valve ∅6 mm 451-006-060


Pressure-relief valve ∅8 mm 451-008-060

33
Pump unit

P 653S (oil)
Pump units for oil

Description
Technical data
Suitable for multiple applications, the Lincoln P 653S electrically
driven oil pump simplifies the design of your lubrication system and Function principle electrically operated piston pump
delivers significant flexibility A member of the Centro-Matic family, Outlets 1
Metering quantity 24,6 cm 3/ min, 1.5 in 3/ min
the pump comes complete with a reservoir, pressure switch/trans- Lubricant oil, minimum 40 mm 2/ s (cST)
ducer, vent valve and controller in one compact unit Operating temperature 0 to +50 °C; +32 to +122 °F
Operating pressure with pressure switch: 240 bar, 3 500 psi
with pressure transducer:
Features and benefits factory preset to 82 bar, 1 200 psi
Reservoir 4 l, 1 gal; 8 l, 2 gal
• Integration of major system components Material (reservoir) thermoplastic
reduces labor and overall costs Connection outlet G 1/4
Incoming voltage 120/230 V AC 1)
• Simplifies lubrication system design
Current max 1,7 A
• Reduces installation time via “plug-and-go” capability Frequency 47 to 63 Hz
• Minimizes lubricant consumption by running only Pause time max 59 h, 59 min
min 4 min
when the machine is operating Pause time increments 1 hr or 1 min
Pumping time max 12 min
Dimensions depending on model
Applications min 240 × 467 × 235 mm
• Automation max 240 × 508 × 235 mm
min. 9.5 × 18.4 × 9.25 in
• Machine tools max. 9.5 × 20 × 9.25 in
• Glass manufacturing plants Mounting position upright
• Woodworking facilities
Pump elements
• Oil and Gas plants Piston ø 7 mm, 0.3 in
• Steel plants Number connected 3
Protection 1P 6K9K

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
16072 EN
3D
skf-lubrication partcommunity com/3d-cad-models
1) 24 V DC version available on request

34
Pump unit

P 653S (oil)

Pump units for oil


Order information

Order number 120/230 V AC Reservoir Internal Internal Internal and Internal and
50/60 Hz capacity pressure pressure end-of-line end-of-line
switch transducer pressure switch pressure transducer

l gal

80127 • 4 1 • • – –
80128 • 8 2 • • – –

35
Pump unit

KFB
Pump units for oil

Description
Technical data
Used with SKF single-line systems, the KFB series gear pump units
Function principle electrically operated gear pump
supply fluid grease NLGI 000 and 00 and include a pressure-relief Outlets 1
valve and a pressure-limiting valve The pumps are designed for Metering quantity 1) 50 cm 3/ min, 3.05 in 3/ min
supply voltages of 12 V DC and 24 V DC and are controlled either by Lubricant fluid grease of NLGI 000 or 00
Operating temperature –25 to +75 °C; –13 to +167 °F
an integrated electronic control unit or externally, via the machine Operating pressure max 38 bar, 550 psi
control system Depending on the design, the gear pump units are Reservoir KFB(S)1-W: 1 l, 0.26 gal
filled via a filler socket or attached filler coupling KFB(S)1: 1,4 l, 0.37 gal
Material (reservoir) translucent plastic
Connection outlet ø 10 × 1 5
(max 16 m, 52.5 ft)
Features and benefits Dimensions:
KFB(S)1, KFB(S)1-W 216 × 150 × 235 mm
• Compact pump unit 8.5 × 5.9 × 9.3 in
KFB(S)1-4-S1, 245 × 150 × 294 mm
• Integrated pressure-relief valve and pressure-regulating valve KFB(S)1-W-4-S1, 9.6 × 5.9 × 11.6 in
KFB(S)1-6-S1,
• Visual or optional electrical fill-level monitoring KFB(S)1-W-6-S1
• Optional integrated control Mounting position vertical

• Optional pre-assembled lubrication distributor of VN series DC motor


Voltage 12, 24 V DC
Current 3,8 A; 1,7 A
Rated output 46 W, 41 W
Applications Protection class IP 6K6K / IP 6K9K
• Commercial vehicles
• Industrial applications
1) At back pressure of 10 bar (145 psi) and a temperature of +25 °C (+77 °F)

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1206-EN, 951-170-009 EN
3D
skf-lubrication partcommunity com/3d-cad-models

36
Pump unit

KFB

Pump units for oil


Order information

Lubricant Electrical connections


Fluid grease Control Fill-level Circular connector Circular connector
Order number NLGI 000, 00 unit switch AMP, 4-pin AMP, 7-pin Design

KFB1 1) • – – • – Basic version


KFB1-W 1) • – • – • Basic version
KFBS1 1) • • – – • Basic version
KFBS1-W 1) • • • – • Basic version

KFB1-4-S1 1) • – – • – VN metering device, 4-outlets


KFBS1-4-S1 1) • • – – • VN metering device, 4-outlets
KFB1-6-S1 1) • – – • – VN metering device, 6-outlets
KFBS1-6-S1 1) • • – – • VN metering device, 6-outlets

KFB1-W-4-S1 1) • – • – • VN metering device, 4-outlets


KFBS1-W-4-S1 1) • • • – • VN metering device, 4-outlets
KFB1-W-6-S1 1) • – • – • VN metering device, 6-outlets
KFBS1-W-6-S1 1) • • • – • VN metering device, 6-outlets

1) All units for vehicle applications have type approval pursuant to ECE-R 10

Additional technical data for KFB(S)1, KFB(S)1-W, KFB(S)1-4-S1, KFB(S)1-W-4-S1, KFB(S)1-6-S1, KFB(S)1-W-6-S1

Fill-level switch (for KFB(S)1-W) opens when fill level too low

Switching voltage 10 to 36 V DC
Switching current Resistive load 1): ≤0 5 A
Switching capacity Resistive load 1): ≤12 W

Relubrication metering device VN (KFB(S)1(-W)4-S1, KFB(S)1(-W)-6-S1)

Lubrication point connection Push-to-connect fitting for tube ø 4 mm


Metering quantity 0 1; 0 2; 0 4 cm 3
Feeder body material Die-cast zinc, black corrosion protection

Control unit IG502-2-I (KFBS1)

Interval, adjustable 0 1 99 9 h
Pump run time, adjustable 0 1 99 9 min
Max pump run time 3 0 min 2)
Elapsed-hours counter 0 99999 9 h
Fault-hours counter 0 99999 9 h

Additional input power for units


with control unit (without output load) 4W

1) When switching inductive loads, take appropriate measures to protect contacts


2) The operating mode S3 (periodic duty) describes the ratio of pump run time to subsequent down time If the relative ON-time is 2 5% and the duty cycle time is 10 to 120 min ,
then the limit values are as follows:
Min duty cycle time: 10 min×0 025 = 0 25 min pump run time with subsequent down time of 9 75 min
Max duty cycle time: 120 min×0 025 = 3 min pump run time with subsequent down time of 117 min

37
Pump unit

KFB-M
Pump units for oil

Description
Technical data
Used with SKF MonoFlex single-line systems, the KFB series gear
Function principle electrically operated gear pump
pump units supply fluid grease NLGI 000 and 00 and include a pres- Outlets 1
sure-relief valve and a pressure-limiting valve The pumps are Metering quantity 1) 50 cm 3/ min, 3.05 in 3/ min
designed for supply voltages of 24 V DC and are controlled either by Lubricant fluid grease of NLGI grade 000 or 00
Operating temperature 0 to +60 °C; +32 to +140 °F
an integrated electronic control unit or externally, via the machine Operating pressure max 38 bar, 550 psi
control system Depending on the design, the gear pump units are Reservoir KFB1-M: 1,4 l, 0.37 gal
filled via a filler socket or attached filler coupling KFB(S)1-M(-W): 1 l, 0.26 gal
Material (reservoir) translucent plastic
Connection outlet ø 8 × 1,25 (max 16 m, 52.5 ft)
Dimensions:
Features and benefits KFB1-M, KFB1-M-W, KFBS1-M, 216 × 150 × 235 mm
KFBS1-M-W 8.5 × 5.9 × 9.3 in
• Compact pump unit
KFB1-M-W-S1 216 × 150 × 270 mm
• Integrated pressure-relief valve and pressure-regulating valve 8.5 × 5.9 × 10.6 in
Mounting position vertical
• Visual or optional electrical fill-level monitoring
• Optional integrated control DC motor
Voltage 24 V DC 2)
Current 1,7 A
Rated output 41 W
Applications Protection class IP 65
• Automation Fill-level switch (KFB1-M-W) (change-over contact)
Switching voltage 24 V DC 2)
• Automotive Switching current (resistive load) 3) ≤0 5 A
Switching capacity (resistive load) 3) ≤12 W
• Machine tools
Control unit IG502-2-I (KFBS1)
Interval, adjustable 0 1 99 9 h
Pump run time, adjustable 0 1 99 9 min
NOTE Max pump run time 2 4 min
Elapsed-hours counter 0 99999 9 h
Further technical information, technical drawings, Fault-hours counter 0 99999 9 h
accessories, spare parts or product function descriptions Additional input power for
available on SKF com/lubrication: units with control unit
(without output load) 4W
1-1206-EN; 951-170-009
3D 1) At back pressure of 10 bar and a temperature of +25 °C; +77 °F
2) Safety measures to be applied for correct operation:
Protective extra-low voltage (PELV), standards: EN 60204-1/IEC 60204-1;
skf-lubrication partcommunity com/3d-cad-models HD 60364-4-41/DIN EN 0100-410/IEC 60364-4-41
3) When switching inductive loads, take appropriate measures to protect contacts

38
Pump unit

KFB-M

Pump units for oil


Order information

Lubricant Electrical connections


Oil Fluid grease Control Fill-level Square connector Circular connector
Order number viscosity 50–50 000 mm 2/ s NLGI 000, 00 unit switch 3-pin +PE M 12 × 1, 4-pin

KFB1-M+924 – • – – • –
KFBS1-M+924 – • • – • •

KFB1-M-W+924 – • – • • •
KFBS1-M-W+924 – • • • • •

39
Pump unit

KFU
Pump units for oil

Description
Technical data
The gear pump continuously supplies lubricant to relubrication
Function principle electrically operated gear pump
metering devices via the main line network when the pump is in Outlets 1
operation When the metering chambers of the metering devices are Metering quantity 1) 140 cm 3/ min, 8.5 in 3/ min
full, excess lubricant flows back into the reservoir via the safety valve Lubricant fluid grease, NLGI 000, 00
Operating temperature –25 to +75 °C; –13 to +167 °F
At the end of the pump running time, the pressure relief valve opens Operating pressure max 38 bar, 550 psi
so that pressure in the main line drops to a residual pressure of 0 2 Reservoir 2,7 or 6 l; 0.7 or 1.6 gal
to 1 0 bar (2.9 to 14.5 psi), allowing the spring-loaded pistons of the Material steel, plastic
sealings: FKM, NBR
metering devices to deliver lubricant from the metering chambers to reservoir: translucent plastic
the lubrication points Main connection Mainly plastic tubing ø 10 × 1 5
but also steel tubing ø 10 × 0 7
hose SLH10-
Secondary connection Mainly plastic tubing ø 4 × 0 85 ;
Features and benefits in case of large movement between
lubrication point and chassis:
• Includes gear pump with relief valve, safety valve, DC motor, hose 734 …
transparent lubricant reservoir, filler socket and angle bracket Operating voltage 12 or 24 V DC
Protection class IP 59k
• Hood protects DC motor and filler socket from contaminants Dimensions min 268 × 154 × 325 mm
max 343 × 184 × 364 mm
• Minimizes wear and tear min. 10.5 × 6 × 12.7 in
• Reduces downtime max. 13.5 × 7.2 × 14.3 in
Mounting position vertical
• Lowers maintenance costs via automatic lubrication

Applications
1) At back pressure 38 bar (550 psi) and temperature +25 °C (+77 °F)
• Agriculture
• Construction machinery
NOTE
• Trucks, trailers and buses Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-9420-EN, 951-170-006_EN
3D
skf-lubrication partcommunity com/3d-cad-models

40
Pump unit

KFU

Pump units for oil


Order information
Order number Reservoir Operating voltage

l gal V DC Amp

KFU2-40+912 2,7 0.71 12 75


KFU2-40+924 2,7 0.71 24 75

KFU6-20+912 1) 6 1.6 12 75
KFU6-20+924 1) 6 1.6 24 75

KFUS2-64+912 2,7 0.71 12 16


KFUS2-64+924 2,7 0.71 24 8

1) This unit should only be used for systems with a minimum lubricant consumption of 6 l (1.6 gal) per year

41
Pump unit

MKU
Pump units for oil

Description
Technical data
MKU gear pump units are used in single-line systems and include a
Function principle electrically operated gear pump
pre-installed pressure-regulating valve and pressure-relief valve Metering quantity 100; 200; 500 cm 3/ min
These units can be supplied with an optional pressure gauge for 6; 12; 31 in 3/ min
visual monitoring of pressure changes in the main line Electrical Lubricant mineral oil or synthetic oil,
20 to 1 500 mm 2/ s
pressure monitoring is performed by an integrated pressure switch, Operating temperature +10 to +40 °C
and fill-level monitoring also is possible The pump units are con- +50 to +104 °F
trolled externally via the machine control system or an integrated Operating pressure max 30 bar, 435 psi
Reservoir 2,0; 3,0 and 6,0 l
control unit Also, MKU units can be supplied with a pushbutton to 0.5, 0.8 and 1.6 gal
activate interim lubrication at any time Main functions are integrated Material (reservoir) plastic, metal
into the lid, and a plastic cap protects the electrical components from Connection outlet G 1/4
Operating voltage 24 V DC; 115 V AC; 230 V AC
contaminants such as dirt and dust Protection class IP 54

Dimensions:
Features and benefits pump unit with
2 l; 0.5 gal plastic reservoir 204 × 130 × 298 mm
• Integrated pressure limitation and pressure relief valve 8 × 5.2 × 11.7 in
3 l; 0.8 gal plastic reservoir 286 × 132 × 298 mm
• Optional: electrical pressure switch, pressure gauge, float switch 11.3 × 5.2 × 11.7 in
3 l; 0.8 gal metal reservoir 286 × 132 × 313 mm
• External control via SPS or by means of 11.3 × 5.2 × 12.3 in
internal control unit possible 6 l; 1.5 gal plastic reservoir 290 × 178 × 334 mm
11.4 × 7 × 13.2 in
• All important functions integrated into the lid Mounting position vertical

• Modular construction

Applications
• Material handling NOTE
Further technical information, technical drawings,
• Automotive
accessories, spare parts or product function descriptions
• Machine tool available on SKF com/lubrication:
• Printing and finishing 1-1203-EN, 951-170-005 EN
• Industrial assembly and automation 3D

• Textiles skf-lubrication partcommunity com/3d-cad-models

42
Pump unit

MKU

Pump units for oil


Identification code M K U – 1 0 0 0 +

Product series MKx

Code number

Selected code number for lubricant reservoir


Lubricant

for delivery
U = Oil

rate
Delivery rate Voltage key

Selected code number for electrical connection


Selected code number for pressure gauge
1 = 0.1 l/min • • • – Voltage Frequency Control
2 = 0 2 l/min – • • • 924 3) 24 V DC – A, B, E

Selected code letter for monitoring


5 = 0 5 l/min – • • • 428 230 V AC

Selected code letter for control


50/60 Hz A, B, C, D, E
429 115 V AC

Lubricant reservoir, control


3) Only possible with delivery rates 0 1 und 0 2 l/min
Lubricant reservoir 1 2 3 4
3 l, metal
plastic

plastic

plastic

Electrical connection
3 l,
2 l,

6 l,

Control A, C,
A, B E
Control B D
A =No control, Monitoring X A B C D E C C
• • • •
with terminal strip
Electrical connection
B = No control,
with terminal strip • • • • 0 = 2 cable fittings – • • • • • • –
and push button 1 = 1 cable fitting; – • • • • • • •
C = IG38-30-I 1) – • • • 1 retangular
connector
D = IZ38-30-I 1) – • • • 2 = 1 circular connector – • • • • • – –
M 12×1; 1 rectan-
E = IGZ36-20-S6-I 1) 2) – • • • gular connector 4)
3 = 1 sealing plug; • – – – – – – –
1) If control C, D or E is selected, monitoring C must be selected 1 cable fitting
2) If control E is selected, electrical connection 1 must be selected
For description of control units, see page 147 4 = 1 sealing plug; • – – – – – – –
1 rectangular
connector

4) Only for design without control

Pressure gauge
0 = without pressure gauge
Monitoring 1 = with pressure gauge
X A B C D E
Fill-level switch Order example
Without fill-level switch • • – – – –
NC contact MKU1-11AC10000+924
– – • • – – • Gear pump unit for oil
(detection of wire breakage)
NO contact • Delivery rate 0 1 l/min
– – – – • • • 1st generation
(no detection of wire breakage)
• 2 l plastic reservoir
• No control, with terminal strip
Pressure switch 20 bar • NC fill-level switch,
• NO pressure switch
Without pressure switch • – • – • – • With pressure gauge
NO contact – • – • – • • 2 cable fittings
• Voltage 24 V DC
10.5

43
Pump unit

MKF
Pump units for oil

Description
Technical data
MKF gear pump units are used in single-line systems to supply
Function principle electrically operated gear pump
fluid greases NLGI 000 and 00 and include a pressure-regulating Metering quantity 100; 200; 500 cm 3/ min
valve and pressure-relief valve Electrical pressure monitoring is 6; 12; 31 in 3/ min
performed by an integrated pressure switch, and fill-level monitoring Lubricant fluid grease NLGI 000 or 00, compatible
with plastics, NBR elastomers, copper
also is possible These units are controlled externally via the machine and copper alloys
control system or an integrated control unit Also, MKF units can be Operating temperature +10 to +40 °C; +50 to +104 °F
supplied with a pushbutton to activate interim lubrication at any Operating pressure max 30 bar, 435 psi
Reservoir 2,0; 3,0 and 6,0 l, 0.5, 0.8 and 1.6 gal
time Main functions are integrated into the lid, and a plastic cap Material (reservoir) plastic, metal
protects the electrical components from contaminants such as Connection outlet G 1/4
dirt and dust Operating voltage 24 V DC; 115 V AC; 230 V AC
Protection class IP 54

Dimensions:
Features and benefits pump unit with
2 l; 0.5 gal plastic reservoir 204 × 130 × 298 mm
• Integrated pressure-limitation and pressure-relief valve 8 × 5.2 × 11.7 in
3 l; 0.8 gal plastic reservoir 286 × 132 × 298 mm
• Optional: electrical pressure switch, pressure gauge, float switch 11.3 × 5.2 × 11.7 in
3 l; 0.8 gal metal reservoir 286 × 132 × 313 mm
• External control via SPS or by means of internal 11.3 × 5.2 × 12.3 in
control unit possible 6 l; 1,5 gal plastic reservoir 290 × 178 × 334 mm
11.4 × 7 × 13.2 in
• All important functions integrated into the lid Mounting position vertical
• Modular construction

Applications
• Material handling
NOTE
• Automotives
Further technical information, technical drawings,
• Machine tool accessories, spare parts or product function descriptions
• Printing and finishing available on SKF com/lubrication:
1-1203-EN, 951-170-005 EN
• Industrial assembly and automation
3D
• Textiles
skf-lubrication partcommunity com/3d-cad-models

44
Pump unit

MKF

Pump units for oil


Identification code M K F – 1 0 0 0 +

Product series MK

Code number

Selected code number for lubricant reservoir


Lubricant

for delivery
F = Fluid grease

rate
Delivery rate Voltage key

Selected code number for electrical connection


Selected code number for pressure gauge
1 = 0.1 l/min • • – Voltage Frequency Control
2 = 0 2 l/min – • • 924 24 V DC – A, B, E

Selected code letter for monitoring


428 230 V AC

Selected code letter for control


50/60 Hz A, B, C, D, E
429 115 V AC

Lubricant reservoir, control


Lubricant reservoir 1 2 4
plastic

plastic

plastic

Electrical connection
3 l,
2 l,

6 l,

Control A, C,
A, B E
Control B D
A = No control, Monitoring X A B C C C
• • •
with terminal strip
Electrical connection
B = No control,
with terminal strip • • • 0 = 2 cable fittings – • • • • –
and push button 1 = 1 cable fitting; – • • • • •
C = IG38-30-I 1) – • • 1 retangular
connector
D = IZ38-30-I 1) – • • 2 = 1 circular connector – • • • – –
M 12×1; 1 rectan-
E = IGZ36-20-S6-I 1) 2) – • • gular connector 3)
3 = 1 sealing plug; • – – – – –
1) If control C, D or E is selected, monitoring C must be selected 1 cable fitting
2) If control E is selected, electrical connection 1 must be selected
For description of control units, see page 147 4 = 1 sealing plug; • – – – – –
1 rectangular
connector

3) Only for design without control

Pressure gauge
0 = without pressure gauge
Monitoring 1 = with pressure gauge
X A B C
Fill-level switch Order example
Without fill-level switch • • – –
NC contact MKF1-11AC10000+924
– – • • • Gear pump unit for fluid grease
(detection of wire breakage)
NO contact • Delivery rate 0 1 l/min
– – – – • 1st generation
(no detection of wire breakage)
• 2 l plastic reservoir
• No control, with terminal strip
Pressure switch 20 bar • NC fill-level switch,
NO pressure switch
Without pressure switch • – • – • With pressure gauge
NO contact – • – • • 2 cable fittings
• Voltage 24 V DC
10.5

45
Pump unit

MFE
Pump units for oil

Description
Technical data
The gear pump units comprising the MFE series are designed
Function principle electrically operated gear pump
to supply lubricant used in intermittently operated, single-line cen- Outlets 1
tralized lubrication systems The basic setup includes a gear pump Metering quantity 250 to 500 cm 3/ min, 15 to 31 in 3/ min
unit with motor, a 3- or 6 l lubricant reservoir in metal or plastic, or a Lubricant oil 5 to 2 000 mm 2/ s and fluid grease
NLGI 00, 000
15 l metal reservoir and float switch to monitor the minimum per- Operating temperature –10 to +60 °C; +14 to +140 °F
missible level of lubricant In addition to the basic models, units can Back pressure max 17,5; 28 bar
be outfitted with add-ons max. 255, 405 psi
Reservoir 3; 6; 15 l, 0.8, 1.6, 4 gal
Material (reservoir) plastic, metal
Connection outlet M 14×1 5
Features and benefits Operating voltage 230/400 V AC
Protection class IP 54
• Integrated float switch for fill-level monitoring Dimensions:
3 l; 0.8 gal plastic reservoir 303 × 130 × 245 mm; 11.9 × 5.1 × 9.6 in
• Integrated pressure-relief valve and pressure-regulating valve 3 l; 0.8 gal metal reservoir 332 × 178 × 312 mm; 13 × 7 × 12.3 in
6 l; 1,5 gal plastic reservoir 319 × 128 × 265 mm; 12.6 × 5 × 10.4 in
• Motors available for various voltage ranges and approvals 6 l; 1,5 gal metal reservoir 370 × 167 × 330 mm; 14.6 × 6.6 × 12.9 in
• Special designs offered for a wide range of applications 15 l; 4 gal metal reservoir 453 × 200 × 436 mm; 17.8 × 7.8 × 17.2 in
Mounting position vertical
• Suitable for intermittent operation
Floating switch for low-level monitoring of oil
• For remote installation out of reservoir or for built-in reservoir Type of contact 1 change-over;
2 change-over contacts (reed contacts)
• Reliable and versatile Switching voltage max 230 V AC, 230 V DC
Switching current max 0,8 A; 1,0 A
• Suitable for use with metering devices of category 1 and 2 Switching capacity max 60 VA, 40 W 1)
Type of enclosure IP 65
1) Take appropriate measures to protect contacts when switching inductive loads
Applications
• Automotive manufacturing
NOTE
• Metal, including presses
Further technical information, technical drawings,
• Machine tools accessories, spare parts or product function descriptions
• Printing and finishing available on SKF com/lubrication:
1-1202-EN, 951-170-002 EN
• Industrial assembly and automation
3D
skf-lubrication partcommunity com/3d-cad-models

46
Pump unit

MFE

Pump units for oil


MFE pump units for oil

Order number Reservoir Design 1)


Capacity Material

l gal

MFE5-K3-2 3 0.8 Plastic CE basic version without level monitoring


MFE5-KW3-2 3 0.8 Plastic CE basic version with min fill level switch
MFE5-KW3-2-S4 3 0.8 Plastic CE basic version with min fill level switch incl pre-warning
MFE5-KW3-S37+1FV 3 0.8 Plastic UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE5-KW3-S35+1FW 3 0.8 Plastic CCC version with fill level monitoring incl min fill level pre-warning
MFE5-KW3-S24+MPG 3 0.8 Plastic CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning

MFE5-K6 6 1.6 Plastic CE basic version without level monitoring


MFE5-KW6 6 1.6 Plastic CE basic version with min fill level switch
MFE5-KW6-S1 6 1.6 Plastic CE basic version with min fill level switch incl pre-warning
MFE5-KW6-S42+1FV 6 1.6 Plastic UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE5-KW6-S102+1FW 6 1.6 Plastic CCC version with fill level monitoring incl min fill level pre-warning
MFE5-KW6-S33+MPG 6 1.6 Plastic CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning

MFE5-B3-2 3 0.8 Metal CE basic version without level monitoring


MFE5-BW3-2 3 0.8 Metal CE basic version with min fill level switch
MFE5-BW3-2-S28 3 0.8 Metal CE basic version with min fill level switch incl pre-warning
MFE5-BW3-S-S34+1FV 3 0.8 Metal UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE5-BW3-S41+MPG 3 0.8 Metal CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning

MFE5-B7 6 1.6 Metal CE basic version without level monitoring


MFE5-BW7 6 1.6 Metal CE basic version with min fill level switch
MFE5-BW7-S22+1FV 6 1.6 Metal UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE5-BW7-S97+1FW 6 1.6 Metal CCC version with fill level monitoring incl min fill level pre-warning
MFE5-BW7-S107+MPG 6 1.6 Metal CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning
MFE5-BW7-S222+MPG 6 1.6 Metal CE version incl gauge and vent filter, with 6 pin Harting plug with fill level monitoring incl
min fill level pre-warning

MFE5-BW16 15 4 Metal CE basic version with min fill level switch incl pre-warning
MFE5-BW16-S145+1FV 15 4 Metal UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE5-BW16-S96+MPG 15 4 Metal CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning
MFE5-BW16-S222+MPG 15 4 Metal CE version incl gauge and vent filter, with 6 pin Harting plug with fill level monitoring incl min
fill level pre-warning

MFE5-BW30 30 8 Metal CE basic version with min fill level switch


MFE5-BW30-S30 30 8 Metal CE basic version with min fill level switch incl pre-warning
MFE5-BW30-S35+MPG 30 8 Metal CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning
MFE5-BW30-S222+MPG 30 8 Metal CE version incl gauge and vent filter, with 6 pin Harting plug with fill level monitoring incl min
fill level pre-warning
1) Further designs are available on request

MFE pump units for fluid grease

Order number Reservoir Design 1)


Capacity Material

l gal

MFE2-K3-2 3 0.8 Plastic CE basic version without level monitoring


MFE2-K3F-2 3 0.8 Plastic CE basic version with min fill level switch
MFE2-KW3F-S13+1FV 3 0.8 Plastic UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE2-KW3F-S9+MPG 3 0.8 Plastic CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning

MFE2-K6F 6 1.6 Plastic CE basic version without level monitoring


MFE2-K6F-S2 6 1.6 Plastic CE basic version with min fill level switch
MFE2-KW6F-S1 6 1.6 Plastic CE basic version with min fill level switch incl pre-warning
MFE2-KW6F-S37+1FV 6 1.6 Plastic UL/CSA version with fill level monitoring incl min fill level pre-warning
MFE2-KW6F-S41+1FW 6 1.6 Plastic CCC version with fill level monitoring incl min fill level pre-warning
MFE2-KW6F-S20+MPG 6 1.6 Plastic CE version with 6 pin Harting plug with fill level monitoring incl min fill level pre-warning

1) Further designs are available on request

47
Pump units for grease

48
Overview of grease pumps and pump units

Pump units for grease


Manually operated pump units

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Piston Page
NLGI max. max. category 1)

0 1 2 cm3/stroke in3/stroke bar psi kg lib 4 5 6 7

83817 • • • 1,6 0.09 240 3500 0,5 1 – • • • multiple stroke 52


1810 • • • 2,6 0.16 240 3500 2,3 5 – • • • multiple stroke 53

1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range

Air–operated pump units

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Piston Page
NLGI max max category 1)

0 1 2 cm3/stroke in3/stroke bar psi kg lib 4 5 6 7

40PGA • • • 40 2.44 10 145 1,7; 2; 4; 10 3.7; 4.4; 8.8; 22 – • • • single stroke 54


82886, 83886 • • • 7,4 0.45 240 3 500 0,5; 2,0 1; 4.4 – • • • single stroke 56
85442 2) • • • 7,4 0.45 240 3 500 0,5 1 – • • • single stroke 57
85444/45 • • • 7,4 0.45 240 3 500 1,8 4 – • • • single stroke 58

85434/35/36 • • • 18,7; 35,2 1.14; 2.15 240 3 500 2,0 4.5 – • • • single stroke 59
82653/55 • • • 22,9 1.39 240 3 500 2,0 4.5 – • • • single stroke 60
83800/34 • • • 35,2 2.15 240 3 500 2,0 4.5 – • • • single stroke 60

83167 • • • 197 12 240 3 500 5,0 11 – • • • reciprocating 61


83599 • • • 197 12 240 3 500 5,0 11 – • • • reciprocating 62

1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller included or optional

Hydraulically operated pump units

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Piston Page
NLGI max max category 1)

0 1 2 cm3/stroke in3/stroke bar psi kg lib 4 5 6 7

HG 1000 • • – 1 000 61.02 150 2 176 1,0 2.2 • • – – single stroke 63


HG 2000 • • – 2 000 122 150 2 176 2,0 4.4 • • – – single stroke 63

84944, 84961 • • • 180 11 206 3 000 30 60 – • • • reciprocating 64


84960, 84962 • • • 180 11 206 3 000 – – – • • • reciprocating 65

Air–operated barrel pumps

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Piston Page
NLGI max max category 1)

0 1 2 cm3/min in3/min bar psi kg lb 4 5 6 7

MPB • • • 305 18.61 300 4 350 18, 50, 180 40; 120; 400 – • • • reciprocating 66
84050/ 85460 • • • 492 30 240 3 500 27 60 – • • • reciprocating 68
282288 • • • 492 30 240 3 500 55 120 – • • • reciprocating 69
FlowMaster • • • 737 45 206 3 000 16; 27; 41; 35; 60; 90; – • • • reciprocating 70
54; 180 120; 400
1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller included or optional

49
Pump units for grease

50
Overview of grease pumps and pump units

Pump units for grease


Electrically operated pump units

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Voltage Page
NLGI max. max. category 1)

0 1 2 cm3/min in3/min bar psi kg lb 4 5 6 7

P603S 2) 3) • • • 12 0.7 300 4 350 4; 8; 10; 8.8; 18; 22; – • • • 12 / 24 V DC 72


15; 20 33; 44
Minilube 2) • • – 13 0.8 250 3 625 2 4.4 – • • • 12 / 24 V DC 74

KFG • • • 15 0.9 300 4 350 2; 4; 6; 8; 10; 4.4; 8.8; 13; 18; – • • • 12 / 24 V DC; 76
12; 15; 20 22; 26; 33; 44 90-264 V AC

Multilube 2) • • – 16 0.976 200 2 900 4; 10 8.8; 22 – • • • 24 V DC; 78


115 / 230 V AC

P653S 2) 3) • • • 24,6 1.5 317 4 600 4; 8; 15; 20 8.8; 18; 22; 44 – • • • 24 V DC; 80
120 / 230 V AC

1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller included or optional
3) Stainless steel or C5M available

Electrically operated barrel pumps

Product Lubricant Metering quantity Operating pressure Reservoir Metering device Voltage Page
NLGI max max category 1)

0 1 2 cm3/min in3/min bar psi kg lb 4 5 6 7

E-PUMP • • • 55 3.35 240 3 480 18, 50, 180 40; 120; 400 – • • • 20–32 V DC 82

FK 2) • • • 74 4.5 400 5 800 15; 30; 60 22; 66; 132 – • • • 3 phase drive 84

FlowMaster • • • 103 6.3 345 5 000 16; 25; 28; 35; 55; 60; 78; – • • • 12 / 24 V DC; 86
35; 40; 55; 90; 120; 400 120-460 V AC
180

1) Select the recommended fittings, adjust the pump pressure within the recommended metering device pressure range
2) Controller included or optional
3) Stainless steel or C5M available

51
Pump unit

83817
Pump units for grease

Description
Technical data
This manual pump unit has a metal reservoir and a spring-loaded
Order number 83817
follower The indicator pin in the pump base shows when 172 bar
(2 500 psi) system operating pressure has been achieved Function principle manually operated piston pump
Outlets 1
Metering quantity 1,6 cm 3/ stroke, 0.10 in 3/ stroke
Features and benefits Lubricant grease NLGI 0, 1, 2
Operating temperature –20 to +65 °C, –4 to +149 °F
• Number of strokes dependent on connected Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
lubrication points and their dosage Reservoir 0,5 kg, 1 lb
Material steel, brass, copper, polyurethane, nitrile
• Metal reservoir with spring-loaded follower also suitable Filling method 0,4 kg, 14.5 oz, grease cartridge/bulk fill
for replaceable 400 g grease cartridges Connection outlet 1/8 NPTF (F)
Dimensions 387 × 127 × 141 mm
• Simple handling 15.25 × 5 × 5.625 in
Mounting position vertical or horizontal
• Low-cost, efficient method of lubricant distribution
• Pump base with built-in check vent valve and indicator pin
for visual control of max or vent pressure
• Vents when handle is pushed all the way back
• Two different filling couplers available
• For use with metering devices of category 5, 6, 7

Applications
• Construction machinery
• Agriculture
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

52
Pump unit

1810

Pump units for grease


Description
Technical data
The Model 1810 pump unit features a translucent reservoir with
Order number 1810
spring-loaded follower The indicator pin in the pump base shows
when 172 bar (2 500 psi) system operating pressure has been Function principle manually operated piston pump
achieved It can be refilled via the included fitting using the Outlets 1
Metering quantity 2,6 cm 3/ stroke, 0.16 in 3/ stroke
Model 81834 filler pump or other manual pumps equipped Lubricant grease NLGI 0, 1, 2
with a Model 645006 coupler Operating temperature -20 to +65 °C; -4 to +149 °F
Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
Features and benefits Reservoir 2,3 kg, 5 lb
Material acrylic, steel, brass,
copper, polyurethane, nitrile
• Number of strokes dependent on connected Connection outlet 1/4 NPTF (F)
lubrication points and their dosage Dimensions 413 × 181 × 197 mm
16.25 × 7.125 × 7.75 in
• Reservoir with spring-loaded follower Mounting position vertical or horizontal
• Simple handling
• Low-cost, efficient method of lubricant distribution
• Pump base with built-in check vent valve and indicator pin
for visual control of max or vent pressure
• Releases pressure on the lubricant line when handle
is pushed all the way back
• Two different filling couplers available
• For use with metering devices of category 5, 6, 7

Applications NOTE
• Construction machinery Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Agriculture
available on SKF com/lubrication

53
Pump unit

40PGA
Pump units for grease

Description
Technical data
Pump Model 40PGA is a compact lubrication pump unit The splash-
Function principle air operated piston pump
proof pump operates pneumatically and can be controlled and moni- Outlet 1
tored by the remote electric control unit ST-102 or ST-102P The Metering quantity 40 cm 3/ stroke, 2.4 in 3/ stroke
pump is available with a choice of different kind of reservoir sizes and Lubricant grease NLGI 0, 1
Operating temperature -30 to +70 °C, -22 to 158 °F
materials, each featuring a spring-loaded intermediate piston Operating pressure (air) max 10 bar, 145 psi
A low-level alarm is available in aluminum and steel version and Reservoir 1,7; 2; 4 and 10 kg
pump is available with an integrated pressure switch 3.75; 4.40; 8.82 and 22.05 lb
Material stainless steel, plastic, steel
and aluminum
Connection outlet R 1/4 in
Features and benefits Operating voltage 24 V
Transmission ratio 16:1
• Compact, air-operated lubrication pump unit for Protection class IP 65
demanding conditions Dimensions (dep on version) min 270 × 320 × 180 mm
max 570 × 325 × 245 mm
• Part of a modular and modifiable system min. 10.63 × 12.59 × 7.0 in
max. 22.44 × 12.79 × 9.65 in
• Splash-proof pump is offered with: Mounting position vertical and horizontally
- choice of four different reservoir sizes
- spring-loaded, intermediate piston in reservoir
- steel and aluminum reservoirs are equipped with
low level alarm
- optional an integrated pressure switch
• Mechanical relief valve
• Controlled and monitored by a remote timer continuously
• Safe and environmentally friendly
• For use with metering devices of category 5, 6 and 7 NOTE
Further technical information, technical drawings,
Applications accessories, spare parts or product function descriptions
available on SKF com/lubrication:
• Buses and trucks 11678 EN, 11390007_40PGA_01_EN
• Heavy vehicles 3D
skf-lubrication partcommunity com/3d-cad-models

54
Pump unit

40PGA

Pump units for grease


Identification code 40PGA – – – 24 – PS

40PGA pump unit

Reservoir material
A = Aluminium
P = Plastic
S = Stainless steel
Reservoir volume
170 = 1,7 kg; 3.74 lb (plastic reservoir)
2L = 2 kg; 4.4 lb (stainless steel reservoir)
4L = 4 kg; 8.8 lb (aluminum reservoir)
10L = 10 kg; 22 lb (aluminum reservoir)
Operating voltage
24 = 24 V DC

Pressure monitoring
PS = Integrated pressure switch

55
Pump unit

82886, 83668
Pump units for grease

Description
Technical data
All models are air-operated, positive-displacement pumps
Function principle air operated piston pump (single-stroke)
delivering a maximum volume by means of a single stroke of the Outlets 1
pump Solenoid air valves and adjustable, solid-state time controls Metering quantity 7,4 cm 3/ stroke, 0.45 in 3/ stroke
are integrated into the pump body, and translucent, acrylic reservoirs Lubricant grease NLGI 0, 1, 2
Operating temperature –18 to +65 °C; 0 to +150 °F
with spring-loaded followers are available in several sizes Pump Operating pressure min 82 bar, 1 200 psi
discharges lubricant on air-powered forward stroke and releases max 240 bar, 3 500 psi
pressure on the lubricant line on spring-powered return stroke Reservoir 0,5 or 2 kg; 1 or 4.4 lb
Material acrylic
through built-in check/relief valve Includes filler fitting for refilling Connection outlet 1/4 NPTF (F)
reservoir with Model 81834 or other manual pump equipped with Transmission ratio 20:1
Model 645006 coupler Air inlet 1/4 NPTF (F)
Mounting position vertical

Timer
Features and benefits On time min 10 sec; max 1 min 24 sec
Cycle time min 20 sec; max 24 h
• Remote system components such as 3/2-way valves, Voltage 120 V AC, 60 Hz; 110 V AC, 50 Hz
adjustments for air power, and monitoring of pump and Operating temperature –23 to +65 °C; –10 to +150 °F
system are available separately on request
• For use with metering devices of category 5, 6 and 7

Applications
• Cement industry
• Wood-working, food and beverage

Order information NOTE


Order Reservoir Dimensions Further technical information, technical drawings,
number capacity
accessories, spare parts or product function descriptions
kg lb mm in available on SKF com/lubrication

82886 0,5 1.0 263 × 133 × 152 10.4 × 5.3 × 6.0


83668 2,0 4.4 470 × 133 × 152 18.5 × 5.3 × 6.0

56
Pump unit

85442

Pump units for grease


Description
Technical data
Model 85442 is an air-operated, positive-displacement pump
Order number 85442
delivering a maximum volume by means of a single stroke of the
pump Solenoid air valves and adjustable, solid-state time controls Function principle air operated piston pump (single-stroke)
are integrated into the pump body This pump unit is designed to Outlets 1
Metering quantity 7,4 cm 3/ stroke, 0.45 in 3/ stroke
deliver grease to single-line metering devices and includes a special Lubricant grease NLGI 0, 1, 2
high-volume refill fitting Acrylic reservoirs are available in several Operating temperature –23 to +65 °C; –10 to +150 °F
sizes Integrated controls feature LED indicators for “Power On”, Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
“Pump On” and “Alarm” along with a membrane-type, “Manual Reservoir 0,5 kg; 1.0 lb
Lube” switch Material acrylic
Connection outlet 1/4 NPTF (F)
Voltage 120 V AC
Transmission ratio 20:1
Features and benefits Dimensions 133 × 184 × 305 mm
5.25 × 7.24 × 12.02 in
• Reservoir 0,45 kg / 1 lb with spring-loaded follower Mounting position vertical
• Integrated solenoid air valve
Timer and controller
• High-volume refill fitting On time 10 or 30 sec
Off time 1/2 to 30 minor 30 min to 30 h
• For use with metering devices of category 5, 6 and 7 Alarm contacts 8 amps at 250 V AC
Operating temperature –23 to +65 °C; –10 to +150 °F

Applications
• Cement industry
• Wood-working
• Food and beverage
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

57
Pump unit

85444/45
Pump units for grease

Description
Technical data
All models are air-operated, positive-displacement pumps delivering
Function principle air operated piston pump (single-stroke)
a maximum volume by means of a single stroke of the pump. Sole- Outlets 1
noid air valves and adjustable, solid-state time controls are inte- Metering quantity 7,4 cm 3/ stroke, 0.45 in 3/ stroke
grated into the pump body. These pump units are designed to deliver Lubricant grease NLGI 0, 1, 2
Operating temperature –23 to +65 °C; –10 to +150 °F
grease to single-line metering devices and include a special Operating pressure min 82 bar, 1 200 psi
high-volume refill fitting. Acrylic reservoirs are available in several max 240 bar, 3 500 psi
sizes. Integrated controls feature LED indicators for “Power On”, Reservoir 1,8 kg; 4.0 lb
Material acrylic
“Pump On” and “Alarm,” along with a membrane-type, “Manual Connection outlet 1/4 NPTF (F)
Lube” switch. Voltage 120 V AC; 240 V AC
Transmission ratio 20:1
Dimensions 133 × 184 × 527 mm
5.25 × 7.24 × 20.75 in
Features and benefits Mounting position vertical
• Reservoir 1,8 kg / 4 lb with spring-loaded follower Timer and controller
• Integrated, adjustable, solid-state time controls with On time 10 or 30 sec
LED indicators Off time 1/2 to 30 min or 30 min to 30 h
Alarm contacts 8 A at 250 V AC
• Integrated solenoid air valve Operating temperature –23 to +65 °C; –10 to +150 °F
• High-volume refill fitting
• For use with metering devices of category 5, 6 and 7

Applications
• Food and beverage
• Glass industry

Order information NOTE


Order Voltage Transmission Metering Further technical information, technical drawings,
number ratio quantity
accessories, spare parts or product function descriptions
V AC cm 3 / stroke in 3 / stroke available on SKF com/lubrication

85444 120 20:1 7,4 0.45


85445 240 20:1 7,4 0.45

58
Pump unit

85434/35/36

Pump units for grease


Description
Technical data
All models are air-operated, positive-displacement pumps
Function principle air operated piston pump (single-stroke)
delivering a maximum volume by means of a single stroke of the Outlets 1
pump. Solenoid air valves and adjustable, solid-state time controls Metering quantity depending on model:
are integrated into the pump body. These pumps are designed to 18,7 or 35,2 cm 3/ stroke
1.14 or 2.15 in 3/ stroke
deliver grease to single-line metering devices and include a special Lubricant grease NLGI 0, 1, 2
high-volume refill fitting. Acrylic reservoirs are available in several Operating temperature –23 to +65 °C; –10 to +150 °F
sizes. Integrated controls feature LED indicators for “Power On”, Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
“Pump On” and “Alarm,” along with a membrane-type, “Manual Reservoir 2,0 kg; 4.5 lb
Lube” switch. Material acrylic
Connection outlet 1/4 NPTF (F)
Voltage 120 V AC; 240 V AC
Transmission ratio 31:1; 25:1
Features and benefits Dimensions 627 × 166 × 460 mm
24.70 × 6.52 × 18.11 in
• Integrated, adjustable, solid-state time controls with Mounting position vertical
LED indicators
• Integrated solenoid air valves Timer and controller
On time 10 or 30 sec
• High-volume refill fitting Off time 1/2 to 30 min or 30 min to 30 h
• For use with metering devices of category 5, 6 and 7 Alarm contacts 8 A at 250 V AC
Operating temperature –23 to +65 °C; –10 to +150 °F

Applications
• Food and beverage
• Glass industry
• Machine tools

Order information NOTE


Order Voltage Transmission Metering Further technical information, technical drawings,
number ratio quantity
accessories, spare parts or product function descriptions
V AC cm 3 / stroke in 3 / stroke available on SKF com/lubrication

85434 120 31:1 18,70 1.14


85435 240 31:1 18,70 1.14
85436 120 25:1 35,20 2.15

59
Pump unit

82653/55, 83800/34
Pump units for grease

Description
Technical data
All models are air-operated, positive-displacement pumps
Function principle air operated piston pump (single-stroke)
delivering a maximum volume by means of a single stroke of the Outlets 1
pump. Solenoid air valves and adjustable, solid-state time controls Metering quantity 22,9 to 35,2 cm 3/ stroke
are integrated into the pump body. These pump units are designed to 1.4 to 2.15 in 3/ stroke
Lubricant grease NLGI 0, 1, 2
deliver grease to single-line metering devices and include a special Operating temperature –18 to +65 °C; 0 to +150 °F
high-volume refill fitting. Translucent, acrylic reservoirs with spring- Operating pressure min 82 bar, 1 200 psi
loaded followers are available in several sizes. Pump uses air for for- max 240 bar, 3 500 psi
Reservoir 2,0 kg; 4.5 lb
ward and return stroke but dispenses lubricant on forward stroke Material acrylic
only. Return stroke releases pressure on the lubricant line through Connection outlet 1/4 NPTF (F)

included check/relief valve. Transmission ratio 31:1; 25:1


Air inlet 1/4 NPTF (F)
Dimensions 470 × 146 × 533 mm
18.5 × 5.75 × 20.9 in
Features and benefits Mounting position vertical

• Remote system components such as 4/2-way valves, Timer (for 82655 and 83800 only)
adjustments for air power, and monitoring of pump On time min 10 sec
max 1 minute, 24 sec
and system are available separately on request Cycle time min 20 sec
• High-volume refill fitting max 24 h
• For use with metering devices of category 5, 6 and 7 Operating voltage 120 V AC, 60 Hz; 110 V AC, 50 Hz
Operating temperature –23 to +65 °C; –10 to +150 °F

Applications
• Oil and gas industry
Air consumption at 6,9 bar, 100 psi, is 0,004 M 3/min, 0 15 ft 3/min, per stroke
• Chain lubrication

Order information NOTE


Order number Ratio Metering quantity Designation Further technical information, technical drawings,
accessories, spare parts or product function descriptions
cm 3 / stroke in 3 / stroke available on SKF com/lubrication

82653 31:1 22,9 1.4 bare pump


82655 31:1 22,9 1.4 pump with controls
83800 25:1 35,2 2.15 pump with controls
83834 25:1 35,2 2 15 bare pump

60
Pump unit

83167

Pump units for grease


Description
Technical data
Model 83167 is an air-operated, positive-displacement pump
Order number 83167
delivering a maximum volume by means of a single stroke of the
pump Solenoid air valves and adjustable, solid-state time controls Function principle air operated reciprocating piston pump
are integrated into the pump body This pump unit is designed to Outlets 1
Metering quantity 197 cm 3/ stroke, 12 in 3/ stroke
deliver grease to single-line metering devices and includes a special Lubricant grease NLGI 0, 1, 2
high-volume refill fitting Acrylic reservoirs are available in several Operating temperature –35 to +104 °C; –30 to +220 °F
sizes Model 83167 includes a transparent reservoir, spring-loaded Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
follower, vent valve assembly and filler fitting for refilling the Transmission ratio 40:1
reservoir Reservoir 5,0 kg; 11.0 lb
Material acrylic, nitrile, neoprene,
steel, aluminum, zinc
Connection outlet 3/4 NPTF (F)
Features and benefits Air inlet 1/8 NPTF (F)
Dimensions 413 × 229 × 571,5 mm
• 2 1/2 inch air motor 16.25 × 9.0 × 22.5 in
• Vent valve assembly Mounting position vertical

• Operation by air-powered reciprocating strokes


and releases pressure on the lubricant line through included
check/relief valve (3-way) on air-powered return stroke
• Remote system components such as 3/2-way valves,
adjustments for air power, and monitoring of pump are
available separately on request
Pump requires 3-way air valve
• Two different filling couplers available Air consumption at 6,9 bar, 100 psi, is 0,004 M 3/min, 0.15 ft 3/min, per stroke

• For use with metering devices of category 5, 6 and 7

NOTE
Applications Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Cement industry
available on SKF com/lubrication
• Food and beverage

61
Pump unit

83599
Pump units for grease

Description
Technical data
Model 83599 is an air-operated, positive-displacement pump deliv-
ering a maximum volume by means of a single stroke of the pump. Order number 83599
Solenoid air valves and adjustable, solid-state time controls are inte-
Function principle air operated, reciprocating piston pump
grated into the pump body. The pump is designed to deliver grease to Outlets 1
single-line metering devices and includes a special high-volume refill Metering quantity 197 cm 3/ stroke, 12 in 3/ stroke
Lubricant grease NLGI 0, 1, 2
fitting. Acrylic reservoirs are available in several sizes. Model 83599 Operating temperature –34 to +121 °C; –30 to +250 °F
is similar to Model 83167 except that it includes a base-mounting kit Operating pressure min 82 bar, 1 200 psi
and metal reservoir with indicator rod for visual check of grease level max 240 bar, 3 500 psi
Transmission ratio 40:1
The reservoir includes a spring-loaded follower Reservoir 5,0 kg; 11.0 lb
Material acrylic, nitrile, neoprene,
steel, aluminum, zinc
Features and benefits Connection outlet 3/4 NPTF (F)
• 2 1/2 inch air motor Air inlet 1/4 NPTF (F)
Dimensions 462 × 229 × 697 mm
• Reservoir with spring-loaded follower 18.19 × 9.0 × 27.44 in
and indicator rod for visual check of grease level Mounting position vertical
• Vent valve assembly
• Base mounting kit
• Operation by air-powered reciprocating strokes
and releases pressure on the lubricant line through included
check/relief valve (3-way) on air-powered return stroke
• Remote system components such as 3/2-way valves,
adjustments for air power, and monitoring of pump
are available separately on request Pump requires 3-way air valve
Air consumption at 6,9 bar, 100 psi, is 0,004 M 3/min, 0 15 ft 3/min, per stroke
• Two different filling couplers available
• For use with metering devices of category 5, 6 and 7
NOTE
Applications Further technical information, technical drawings,
• Machine tools accessories, spare parts or product function descriptions
• Industrial machinery available on SKF com/lubrication

62
Pump unit

HG 1000, HG 2000

Pump units for grease


Description
Technical data
The hydraulic lubricator HG is an lubrication system developed for
a cost-efficient automatic lubrication in machines and implements Function principle hydraulicly operated, piston pump
having a hydraulic circuit. With the help of the hydraulic lubricator, Outlets 1
Metering quantity:
centralized automatic lubrication can be adapted to such units as HG 1000 max 1 000 cm3/stroke; 61 in3/stroke
dismountable hoists, small lift trucks and rear lifts of vehicles. HG 2000 max 2 000 cm3/stroke; 122 in3/stroke
Lubricant grease NLGI 0, 1
Operating temperature –25 to +80 °C; –13 to +176 °F
Operating pressure min 50 bar, 725 psi
Features and benefits max 150 bar, 2 176 psi
Transmission ratio 1:1
• Simple piston pump utilizes self-relieving hydraulic lines Reservoir 1 and 2 kg; 2.2 and 4.4 lb
• Provides cost-efficient automatic lubrication Material (reservoir) steel
• Suitable for use in vehicles or machines having a safe Grease outlet connection R 1/4 in ZN; main hose ø 8 mm, 0.341 in
Hydraulic inlet connection R 1/4 in ZN; main hose ø 8 mm, 0.341 in
hydraulic circuit that is not constantly in operation Operating voltage 12 or 24 V DC
• Pressure rise and fall operation in the pump is activated by Dimensions:
HG 1000 345 × 100 × 100 mm; 13.58 × 3.94 × 3.94 in
powering-on and powering-off the adapted hydraulic circuit
HG 2000 520 × 100 × 100 mm; 20.47 × 3.94 × 3.94 in
• Pressure rise and fall operation in the lube line, as well Mounting position vertical or horizontal
as the amount of lube remaining, can be verified from
the pressure gauge of the pump unit
• Optional low-level limit alarm can be indicated by Order information
a buzzer or indicator lamp 12 or 24 V DC Order number Designation Weight
• Filling coupler with filter kg lb
• For use with metering devices of category 4 and 5
11390060 HG-1000 Pump 7,2 15.8
11390070 HG-2000 Pump 10,2 22.4
Applications
• Vehicles
• Machines NOTE
• Dismountable hoists Further technical information, technical drawings,
• Small lift trucks accessories, spare parts or product function descriptions
• Rear lifts of trucks available on SKF com/lubrication

63
Pump unit

84944, 84961
Pump units for grease

Description
Technical data
Models 84944 and 84961 are pumping systems designed to operate
Order number 84944; 84961
centralized lubrication systems that utilize single-line, parallel grease
metering components The pump is double acting, dispensing lubri- Function principle hydraulically operated,
cant on both the up and down strokes These units are designed for double-acting piston pump
Outlets 1
off-road equipment that utilizes 24 V DC power sources These units Metering quantity 180 cm 3/ stroke, 11 in 3/ stroke
can be used in conjunction with: Lubricant grease NLGI 0, 1, 2
Models 244270 (not potted) or 249605 (potted) cycle timers; Operating temperature –40 to +57 °C; –40 to +135 °F
Fluid inlet temperature max +99 °C; +210 °F
Model 84944 hydraulically operated pump with 60 lb metal Hydraulic inlet pressure min 20 bar, 300 psi
reservoir and vent valve (basic pump); and Model 84961 basic max 205 bar, 3 000 psi
pump (similar to Model 84944 but without reservoir or vent valve) Pressure ratio 16:1
Reservoir 27,0 kg; 60.0 lb
These products include a pump and hydraulic control Material steel, brass, copper, polyurethane, nitrile
Connection outlet 3/4 NPTF (M)
Hydraulic inlet/outlet 1/4 NPTF (M)

Features and benefits Flow rate at 30 cycles/min: 3,8 l/min, 1.0 gal/min
Operating voltage 24 V DC
• Robust Dimensions:
84944 381 × 495,3 × 889 mm
• Pump operates by an electrical signal 15 × 19.5 × 35 in
84961 76 × 177,8 × 866,8 mm
• Supplied with metal reservoir with removable cover 3 × 7 × 34.125 in
for easy filling Mounting position vertical

• Includes a hydraulic operated solenoid vent valve 24 V DC Cycle timer


Voltage 24 V DC
• Includes a hydraulic pressure reduction valve rated Cycle rate per min min 6, max 60
4 to 55 bar (60 to 800 psi) output
• Bulk filling method
• For use with metering devices of category 5, 6 and 7 NOTE
Further technical information, technical drawings,
Applications accessories, spare parts or product function descriptions
available on SKF com/lubrication
• Construction machinery
• Heavy machines
• Vehicles

64
Pump unit

84960, 84962

Pump units for grease


Description
Technical data
Models 84960 and 84962 are pumps designed to operate central-
ized lubrication systems that utilize single-line parallel grease Order number 84960; 84962
metering components The pumps are double acting, dispensing
Function principle hydraulically operated,
lubricant on both the up and down strokes These units are designed double-acting piston pump
for off-road equipment that utilizes 24 V DC power sources These Outlets 1
Metering quantity 180 cm 3/ stroke, 11 in 3/ stroke
units can be used in conjunction with Models 244270 (not potted) or Lubricant grease NLGI 0, 1, 2
249605 (potted) cycle timers Included hydraulic solenoids require Operating temperature –40 to +57 °C; –40 to +135 °F
24 V DC Model 84960 is a hydraulic pump for use with U S standard Fluid inlet temperature max +99 °C; +210 °F
Hydraulic inlet pressure min 20 bar, 300 psi
120 lb refinery drums System components (pump, vent assembly, max 205 bar, 3 000 psi
drum cover and follower plate) must be ordered separately Pressure ratio 16:1
Model 84962 is a hydraulic pump for custom lubricant container Material steel, brass, copper, polyurethane, nitrile
Connection outlet 3/4 NPTF (F)
installations Pump length is sized for U S standard 400 lb refinery Hydraulic inlet/outlet 1/4 NPTF (M)
drum depth Flow rate at 30 cycles/min: 3,8 l/min, 1.0 gal/min
Operating voltage 24 V DC
Dimensions:
84960 76 × 177,8 × 1 083 mm
Features and benefits 3 × 7 × 42.625 in
84962 76 × 177,8 × 862 mm
• For use with U S standard 54 kg (120 lb) refinery drum 3 × 7 × 33.94 in
• Robust Mounting position vertical
• Includes a hydraulic pressure reduction valve rated Cycle timer
4 to 55 bar (60 to 800 psi) output Voltage 24 V DC
• System components (pump, vent valve assembly, Cycle rate per min min 6, max 60
Pumps require a timed electrical signal to operate Use 244270 (not potted) or 249605 (potted)
drum cover and follower plate) must be ordered separately cycle timer Included hydraulic solenoids require 24 V DC All pumps have a hydraulic pressure-
• For use with metering devices of category 5, 6 and 7 reducing valve rated for 4 to 55 bar, 60 to 800 psi, output Maximum input is 207 bar (3 000 psi)

Applications NOTE
• Mining industry Further technical information, technical drawings,
• Cement industry accessories, spare parts or product function descriptions
available on SKF com/lubrication

65
Pump unit

MPB
Pump units for grease

Description
Technical data
The MPB pump unit is especially designed for automatic lubrication
systems The unique feature in it compared to traditional air-oper- Function principle air operated piston pump
for barrels
ated barrel pump with mechanical air motor valve is its magnetically Operating temperature –10 to +55 °C, 14 to 131 °F
operated air motor valve This will reduce the amount of mechanical Operating pressure max 300 bar, 4 350 psi
components in the air motor and also eliminates the need of lubrica- Pressure ratio 1:65
Pressure air supply 2 to 4,5 bar, 29 to 65 psi
tion in the air motor The pump is suitable for use with 18, 50 and Air consumption max 300 l/min; 80 gal/min
180 kg (40, 120 and 400 lb) lubricant barrels And when equipped Lubricant grease up to NLGI 2
oil up to 20–10 000 mm2/s
with a suitable adapter MPB pump unit can also be used in lubricant
Metering quantity per cycle 1) 6,1 cm3; 0.37 in3
bulk containers Electrical connections 20–32 V DC
Drum capacity 18, 50 and 180 kg, 40, 120 or 400 lb
drum not included
Features and benefits Protection class IP 65
Dimensions depending on the model
• Lubrication-free, electronically controlled air motor min 650 × 130 × 130 mm
max 920 × 130 × 130 mm
enables accurate control of pump output min. 25.6 × 5.11 × 5.11 in
max. 36.22 × 5.11 × 5.11 in
• Fewer mechanical components extend Mounting position vertical
a service life of the air motor
• Includes self-diagnosing system
• Operates effectively in wide range of temperatures
• IP 65 protection rating

1) generally approx 50 cycles/min are assumed


Applications
• Paper industry
NOTE
• Steel industry
Further technical information, technical drawings,
• Heavy industry accessories, spare parts or product function descriptions
available on SKF com/lubrication:
PUB LS/P8 17178 EN

66
Pump unit

MPB

Pump units for grease


Order information

Order number Designation Suitable barrel size

kg lb

12381702 SKF-MPB-PUMP-1/8 18 40

12381701 SKF-MPB-PUMP-1/4 50 120

12381700 SKF-MPB-PUMP-1/1 180 400

Accessories

Air regulator unit Air regulator unit

Order number Designation

12382666 MAX-V2-SET-MPB

Lid sets Lid sets

Order number Designation

ECO version - dynamic pump position on barrel (acc. to filling level)


12381381 MAXV2-LIDSET-1/1-ECO-MPB
12381382 MAXV2-LIDSET-1/4-ECO-MPB
12381383 MAXV2-LIDSET-1/8-ECO-MPB

STA version - static pump position on barrel


12381384 MAXV2-LIDSET-1/1-STA-MPB
12381385 MAXV2-LIDSET-1/4-STA-MPB
12381386 MAXV2-LIDSET-1/8-STA-MPB

67
Pump unit

84050, 85460
Pump units for grease

Description
Technical data
Models 84050 and 85460 are air-operated, double-acting pumps
for high-volume displacement Both pumps are supplied with a Order number 84050
27 kg (60 lb) capacity metal reservoir with removable cover for easy 85460
filling It includes an air-operated vent valve and air and lubricant Function principle air operated, double-acting piston pump
connecting hoses Model 85460 features a visual low-level and Outlets 1
Metering quantity 492 cm 3/ stroke, 30 in 3/ stroke
follower plate assembly Lubricant grease NLGI 0, 1, 2
Operating temperature –23 to +60 °C; –10 to +140 °F
Operating pressure min 82 bar, 1 200 psi
Features and benefits max 240 bar, 3 500 psi
Transmission ratio 50:1
• Rugged, 14-gauge steel walls Reservoir 27,0 kg; 60.0 lb
• Large 1 inch NPT inlet for fast filling, 1 1/4 in overflow outlet Material (reservoir) steel
Connection outlet 3/4 NPTF (F)
• 2 inch foam follower that virtually eliminates grease bypass Air inlet 3/8 NPTF (F)
• Vent valve to bucket coupling Dimensions 806 × 392 × 395 mm
31.75 × 15.44 × 15.56 in
• Thick mounting ring that withstands severe vibration
Mounting position vertical
• Bulk filling method
• Remote system components such as 3/2-way valves,
adjustments for air power, and monitoring of pump are
available separately on request
• For use with metering devices of category 5, 6 and 7

Applications
Pump requires 3-way air valve
Air consumption at 6,9 bar, 100 psi, is 0,004 M 3/min, 0 15 ft 3/min, per stroke
• Pulp and paper industry Optional 92597 follower available
• Construction machinery
• Food and beverage
• Mining NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

68
Pump unit

282288

Pump units for grease


Description
Technical data
Model 282288 is an air-operated, positive-displacement pump
delivering a maximum volume by means of a single stroke of the Order number 282288
pump unit. A solenoid air valve is 58
Function principle air operated, reciprocating piston pump
integrated into the pump body. Designed to deliver grease to sin- Outlets 1
Metering quantity 492 cm 3/ stroke, 30 in 3/ stroke
gle-line metering devices, 282288 includes a special high-volume Lubricant grease NLGI 0, 1, 2
refill fitting, a 2 1/2 in pneumatically driven pump, a vent valve assem- Operating temperature –15 to +121 °C; +5 to +250 °F
bly and air and lubricant connecting hoses. Operating pressure min 82 bar, 1 200 psi
max 240 bar, 3 500 psi
Transmission ratio 50:1
Reservoir 55 kg; 120 lb
Features and benefits Drum size standard 120 lb refinery drum
Material nitrile, steel, polyurethane
• Modular structure consists of 2 1/2 in air motor, pump and Connection outlet 3/4 NPTF (F)

vent assembly, air and lubricant connecting hoses Air inlet 3/8 NPTF (F)
Voltage (controller) 120 V, 60 Hz; 110 V, 50 Hz
• For U. S. standard refinery drums (removable head) Dimensions 381 × 381 × 975 mm
• For clean and safe drum replacement 15 × 15 × 38.375 in
• Simplified, modular design Mounting position vertical
• For use with metering devices of category 5, 6 and 7

Applications
• Agriculture
• Chemical industry
• Steel industry Air consumption at 6,9 bar, 100 psi, is 0,004 M 3/min, 0 15 ft 3/min, per stroke
83371 follower plate is available as an optional accessory

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

69
Pump unit

FlowMaster, hydraulic
Pump units for grease

Description
Technical data
High-performance FlowMaster hydraulic pumps combine rota-
Function principle hydraulically operated piston pump
ry-driven pump motors with reciprocating pump tubes and flexible Outlets 1
control features that perform in desert heat and arctic cold The inte- Metering quantity adjustable
grated control manifold adjusts the amount of lubricant and operat- 115 to 737 cm 3/ min
7 to 45 in 3/ min
ing pressure The pump’s output is adjustable from Lubricant grease NLGI 0, 1, 2
115 to 737 cm 3/min (7 to 45 in 3/min) Hydraulic fluid temperature max +93 °C, +200 °F
Operating temperature –29 to +65 °C, –20 to +150 °F
Operating inlet pressure 20 to 32 bar, 300 to 420 psi
Features and benefits Supply inlet pressure max 200 bar, 3 000 psi
Reservoir 16; 27; 41; 54; 180 kg
35; 60; 90; 120; 400 lb
• Increases pump life and simplifies pump installation,
Material fluoroelastomer, polyurethane,
operation and service steel, aluminum zinc casting
• Pump and reservoir combination models are Connection outlet 1/4 NPTF
Hydraulic inlet flow max 28 l/min, 7 gal/min
automatically level-sensor and shut-off system ready Solenoid valve coil 24 V DC
• Premium-choice pump for single-line parallel lubrication systems Hydraulic inlet port SAE 4
• Flexible ranges of use pump only or pump and bucket Tank return port SAE 6
Transmission ratio 9:1 at low inlet pressure (20 to 25 bar,
with follower low- and high-level detection with manifold 300 to 350 psi) and flow (below 7 lpm,
• For desert heat and cold climates 2 gpm); approaches 11:1 at higher inlet
• For use with metering devices of category 5, 6 and 7 pressure and flow
Dimensions:
Pump, dip tube length min 348 mm; 13.7 in
Applications max 864 mm; 34.02 in
Basic pump min 610 × 231 × 291 mm
• Construction machinery, mining and mineral processing max 1 126 × 231 × 291 mm
min. 24 × 9 × 11.5 in
• Steel mills, paper mills, automotive, food and beverage max. 44.3 × 9 × 11.5 in
Pumps with bucket, min 633 × 496mm
follower and vent valve max 1 155 × 496 mm
NOTE min. 24.9 × 19.5 in
max. 45.44 × 19.5 in
Further technical information, technical drawings, Mounting position vertical
accessories, spare parts or product function descriptions
available on SKF com/lubrication

70
Pump unit

FlowMaster, hydraulic

Pump units for grease


Order information

Order number Designation Reservoir Solenoid Adjustable Adjustable


capacity manual flow pressure
override control control

kg lb

85722 pump and bucket with follower and low-level detection 27 60 – • •


85723 reservoir and pump 27 60 – – –
85724 reservoir and pump 27 60 – – –
85725 pump and bucket with follower and low-level detection 41 90 – • •
85726 pump and bucket 41 90 • – –
85727 pump and bucket with follower, low- and high-level detection 54 120 – • •

85731 pump only 16 35 – • •


85732 pump only 27 60 – • •
85733 pump only 54/41 120/90 – • •
85734 pump only 180 400 – • •
85735 pump only 27 60 – – –
85741 pump only 27 60 • – –
85742 pump only 54/41 120/90 • – –

Accessory
Drum cover, follower assembly, vent cvalves etc

Order number Designation Reservoir capacity


gal lb

84616 drum cover 18 120


85492 follower assembly 18 120
84990 vent valve assembly 18 120

271606 drum cover 55 400


270982 follower assembly 55 400
271605 vent valve assembly 55 400

84980 vent valve 18, 55 120, 400

237-11204-8 ultrasonic high/low sensor 18, 55 120, 400

71
Pump unit

P 603S
Pump units for grease

Description
Technical data
The simple-to-install, all-in-one design of the P 603S pump
Function principle electrically operated
includes the programmable controller, a pressure switch/transducer piston pump
and a vent valve It is quick and easy to change out a metering device Outlets 1
as the main line or nearby metering devices do not have to be Metering quantity 12 cm 3/ min, 0.73 in 3/ min
Lubricant grease up to NLGI 2
removed The exchange can be performed between lubrication Operating temperature –40 to +70 °C, –40 to +158 °F
cycles so that there is no wasted lubricant or excessive costly down- Operating pressure max 300 bar, 4 350 psi
time An additional pressure switch at the end of larger systems can Reservoir 4; 8; 10; 15 or 20 kg
9, 18, 22, 33 or 44 lb
be used for added pressure control to ensure correct lubrication For Pumping elements 3 (ø 7 mm, 0.27 in)
rotating operation in wind turbines, the reservoir is equipped with a Paddle 18 rpm
follower plate and stirring paddle, which also facilitates the use of Operating voltage 12, 24 V DC, 115 / 230 V AC
Current draw max 2 A
fast-separating lubricants For stationary operations, a stirring and Protection class IP 6K9K
fixed paddle is sufficient Connectors 12, 24 V DC: bayonet style
AC: bayonet style plus square type
Switching power supply 12, 24 V DC: no AC: yes
Material cast aluminum alloy,
Features and benefits polycarbonate resin
Connection outlet G1/4
• Robust design with easy system layout Dimensions min 471 × 240 × 235 mm
max 949 × 240 × 235 mm
• Simple maintenance min. 18.54 × 9,44 × 9,25 in
• Easy system expandation max. 37.08 × 9,44 × 9,25 in
Mounting position vertical (with follower plate; any)
• SE1/SE2 suction elements for used lubricant
• QSL / SL metering devices suitable for high pressure
• Suitable for fast-separating lubricants
• For use with metering devices of category 5, 6, 7
NOTE
Applications Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Wind turbines available on SKF com/lubrication
• Construction machinery
• Mining and mineral processing
• Commercial vehicles

72
Pump unit

P 603S

Pump units for grease


Order information

Order number Designation Power Reservoir Follower Internal


capacity plate transducer

V kg lb

645-41064-3 P603S-4XLF -3Z7-AC-2A7 16-S13-SE 115 / 230 AC 4 9 • •


645-41062-3 P603S-8XLF -3Z7-AC-2A7 16-S13-SE 115 / 230 AC 8 18 • •
645-41110-2 P603S-8XLBO-3Z7-AC-3A7 16-S12-SE 115 / 230 AC 8 18 – •
645-41062-4 P603S-8XLBO-3Z7-AC-3A7 16-S19-SE 115 / 230 AC 8 18 – •
645-41119-2 P603S-10XLF -3Z7-AC-2A1 01-S13-SE 115 / 230 AC 10 22 • •
645-41073-5 P603S-15XLF -3Z7-AC-2A7 16-S13-SE 115 / 230 AC 15 33 • •

645-41064-8 P603S-4XLF1-3Z7-12-1A7 16-S01-SE 12 DC 4 9 • (bayonet) •


645-41175-5 P603S-4XNBO -3Z7-12-1A7 16-S22-SE 12 DC 4 9 – •
645-41064-7 P603S-4XNBO-3Z7-12-2A7 16-S01-SE 12 DC 4 9 – •
645-41110-3 P603S-8XLF1-3Z7-12-1A7 16-S01-SE 12 DC 8 18 • (bayonet) •

645-41064-4 P603S-4XLBO-3Z7-24-1A7 16-S17-SE 24 DC 4 9 – •


645-41064-6 P603S-4XLF -3Z7-24-1A7 16-S13-SE 24 DC 4 9 • •
645-41064-2 P603S-4XNBO-3Z7-24-1A7 16-S01-SE 24 DC 4 9 – •
645-41062-9 P603S-8XLF -3Z7-24-1A7 16-S01-SE 24 DC 8 18 • •
645-41062-8 P603S-8XLBO-3Z7-24-2A7 16-S19-SE 24 DC 8 18 – •
645-41062-7 P603S-8XLF -3Z7-24-1A7 16-S03-SE 24 DC 8 18 • •
645-41119-1 P603S-10XLF -3Z7-24-1A7 16-S13-SE 24 DC 10 22 • •

Accessory
Reservoir kits

Order number Reservoir capacity Designation

kg lb

276764 15 33 Converts 4 or 8 kg, 9 or 18 lb, reservoirs without follower to 15 kg, 33 lb reservoir


276765 20 44 Converts 4 or 8 kg, 9 or 18 lb, reservoirs without follower to 20 kg, 44 lb reservoir

73
Pump unit

Minilube
Pump units for grease

Description
Technical data
Minilube is a handy solution for vehicles with few lubrication points,
Function principle electrically operated piston pump
such as mini-excavators, mini wheel loaders, buses and Outlets 1
delivery trucks Installing Minilube is easy and quick, because Metering quantity
everything is already integrated: control centre, pressure switch and 12 V DC 6,5 cm 3 / min, 0.4 in 3/ min
24 V DC 13 cm 3/ min, 0.8 in 3/ min
alarm lights Additional alarm lights can be installed, for example, in Lubricant grease up to NLGI 1
the vehicle’s cabin Pumped grease is distributed accurately through Operating temperature –30 to +70 °C, –22 to +158 °F
pre-engineered metering device groups Operating pressure max 250 bar, 3 625 psi
Reservoir 2 kg, 4 lb
Material acrylic, steel, aluminum,
polyurethane, nitrile
Features and benefits Connection outlet R 1/4 in
Operating voltage 12/24 V DC
• Compact lubrication system for few lubrication points Power consumption 150 W, 0 2 HP
Protection class IP 65
• Improves worker safety as system lubricates all connected Dimensions 327 × 273 × 184 mm
lubrication points regardless of machinery location 12.9 × 10.75 × 7.25 in
Mounting position vertical
• Minimizes lubricant waste to environment by maintaining
optimal lubrication level
• Easy and quick installation and commissioning
• For use with metering devices of category 4 and 5

Applications
• Small excavators
• Wheel loaders
• Buses NOTE
• Delivery trucks Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Vehicles
available on SKF com/lubrication:
12236 EN
3D
skf-lubrication partcommunity com/3d-cad-models

74
Pump unit

Minilube

Pump units for grease


Identification code MIN 170 – –

Minilube pump unit

Reservoir
170 = 2 kg, 4 lb

Control system
ST-102 = External control with ST-102 control unit
Empty = With integrated control ST-104
Operating voltage
12 V = 12 V DC
24 V = 24 V DC

75
Pump unit

KFG
Pump units for grease

Description
Technical data
The KFG pump unit is an electrically driven piston pump The pump is
comprised of four main components: housing with pump elements; Function principle electrically operated piston pump
reservoir with fill-level monitoring; internal control units; and attach- Outlets 1–3
Metering quantity 5,0 to 15 cm 3 / min
ments The housing integrates the motor, the drive shaft with an 0.3 to 0.9 in 3/min
eccentric and up to three pump elements for delivering the lubricant Lubricant NLGI 000 to 2 with EP additives,
compatible with plastics, NBR
Positively driven pump elements should be used in order to maintain elastomers, copper and copper alloys
the delivery rate in areas with extremely low temperatures or in Operating temperature
applications where an increased influence of dirt is unavoidable with spring-return pump element –25 to +70 °C, –13 to +158 °F
with posit driven pump element –30 to +70 °C, –22 to +158 °F
Operating pressure max 300 bar; 4 351psi
Features and benefits Flow pressure 0,45 to 0,7 bar, 6.5 to 10.2 psi
Reservoir 2; 4; 6; 8; 10; 12; 15; 20 kg
• Reliable: due to durable materials, robust components 4, 9, 13, 18, 22, 26, 33, 44 lb
and designs for extreme conditions (with positively driven Material (reservoir) polyamide PA 6I, PMMA
Material (pump housing) aluminum-silicon cast alloy
pump elements) Connection outlet M 14×1,5 mm
• Plug-and-play pump design for reduced installation time Operating voltage 12 V DC, 24 V DC, 230 V AC
• Application-oriented: individual designs through (90–264 V AC)
Dimensions min 229 × 268 × 208mm
user-friendly product customizer max 1 170 × 268 × 216 mm
• Versatile: can be used as a single-line (SKF MonoFlex) min 9.01 × 10.55 × 8.2 in
and as a progressive pump (SKF ProFlex) max 46 × 10.55 × 8.5 in
Mounting position vertical (with follower plate; any)
• Safe: through fill-level monitoring, lubrication
system monitoring, pressure relief and control unit
• Options: Top filling, several electronic options, Can bus
• For use with metering devices of category 5, 6 and 7

Applications
• Wind turbines NOTE
• Construction machinery Further technical information, technical drawings,
• Vehicle aftermarket accessories, spare parts or product function descriptions
• Rotary applications available on SKF com/lubrication:
• Industry 1-3030 -EN, 951-170-211
3D
skf-lubrication partcommunity com/3d-cad-models

76
Pump unit

KFG

Pump units for grease


Position of pump elements

Identification code K F G +
1 2 3
Product series

Integrated control unit


X = No control unit L = LC502

Reservoir
1 = 2 kg, 4 lb (not available for
rotary application version)
2 = 4 kg, 9 lb (only rotary application version)
3 = 6 kg, 13 lb
4 = 8 kg, 18 lb (only rotary application version)
5 = 10 kg, 22 lb
6 = 12 kg, 26 lb (only rotary application version)
7 = 15 kg, 33 lb
8 = 20 kg, 44 lb (not available for
rotary application version)
Range of application
R = Rotary M = Industry F = Vehicle
application application application
Filling
X = Without lubricant (not available for rotary application version)
A = Grease NLGI-Grade 2 for vehicles (not for capacitive fill-level monitor)
F = Customized grease
Fill-level monitor
X = Without fill-level monitor
1 = Mechanical level monitor (not available for rotary application version)
2 = Mechanical level monitor with signal smoothing (not available for rotary version;
only possible with KFGX)
3 = Capacitive level monitor (only available for industry versio with 2 and 6 kg reservoir)
4 = Cylinder switch level monitor (only available for rotary application version)
Pump element or filler socket
Spring-return piston pump Positively driven piston pump
X = No pump element Y = No pump element
E = 5,0 cm 3/ min; 0,30 in 3/ min L = 5,0 cm 3/ min; 0,30 in 3/ min
W = Socket for filling cylinder V = Socket for filling cylinder
(not available for rotary application version) (not available for rotary application version)
Fitting for main line connection and valves 3)
S = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ø 6 mm tubes
T = Pressure relief and restriction valve (200 bar/2 900 psi) with SKF Quick Connector for ø 8 mm tubes
U = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ø 10 mm tubes
V = Pressure relief and restriction valve (200 bar/2 900 psi) with solderless pipe union for ø 8 mm tubes
W = Pressure relief and restriction valve (200 bar/2 900 psi) with female thread solderless pipe union
for ø G 1/4 tubes 2)
Pump cycle / interval time
No control unit LC502
99 = none EB = 4 min run time / 1 h interval time Factory setting, additional setting times on request
Voltage key
912 = 12 V DC (only available for vehicle application version) 924 = 24 V DC 486 = 90–264 V AC (not available for vehicle application version)

1) For technical reasons, the first pump element must always be installed at outlet 1 in SKF MonoFlex systems
2) If the relief valve is configured together with several pump elements, then the lines leading from the pump elements will be joined together ahead of the relief valve

77
Pump unit

Multilube MLPV / MLPI


Pump units for grease

Description
Technical data
Multilube pump units (MLPV for heavy vehicles, MLPI for industrial
applications) help to ensure that the lubrication result is optimal, Function principle electrically operated piston pump
Outlets 1 (for single-line applications)
while reducing energy and lubricant consumption All relevant com- Metering quantity 16 cm 3/ min; 0.976 in 3/ min
ponents (control unit, pump, reservoir, directional valve and pressure Lubricant oil, fluid grease and grease up to NLGI 1
Operating temperature –30 to +60 °C, –22 to +140 °F
monitoring) are integrated into its modular pumping unit Built-in
Operating pressure max 200 bar, 2 900 psi
heating allows it to be operated even under demanding and cold Reservoir 4 or 10 kg, 9 or 22 lb
circumstances Material aluminum, polyurethane, nitrile
Connection outlet G 1/4
Operating voltage 12/24 V DC, 115 V AC, 230 V AC
Power consumption 150 W, 0 2 HP
Features and benefits Protection class IP 67 (IP 65 with user-interface IF-103)
• Compact, all-in-one structure Dimensions:
with 4 kg reservoir 539 × 274 × 250 mm
• Modular and durable design with 9 lb reservoir 21.22 × 10.78 × 9.84 in
with 10 kg reservoir 720 × 274 × 250 mm
• Easy to install and start-up with 22 lb reservoir 27.09 × 10.78 × 9.84 in
Mounting position vertical and horizontal
• Can be used in single-line, dual-line and
progressive lubrication systems
• For use in oil and grease lubrication systems
• Two reservoir sizes
• Pumping element equipped with pressure-relief valve
• Filling connection equipped with filling filter
• Visual and electric low-level monitoring in reservoir
• Pumping center is equipped with heating device
• Clear and versatile user interface
• Wide operating temperature range NOTE
• For use with metering devices of category 5, 6 and 7 Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
Applications 6407/2 EN
• Stand-alone machines 3D
• Construction machinery skf-lubrication partcommunity com/3d-cad-models
• Mining applications

78
Pump unit

Multilube MLPV / MLPI

Pump units for grease


MLPV (vehicle applications)

Order number 1) Designation Reservoir capacity Operating voltage Control unit

kg lb 12 V DC 24 V DC

11395200 MLPV-4-1-12 4 9 • – –
11395210 MLPV-4-1-24 4 9 – • –
11395211 MLPV-10-1-24 10 22 – • –

11395227 MLPV-4-1-24-IF103-PSE 4 9 – • IF103


11395254 MLPV-10-1-12-IF103-PSE 10 22 • – IF103

1) Further MLPV versions available on request

MLPI (industrial applications)

Order number 1) Designation Lubri- Reservoir Operating voltage Control Build in


cant capacity unit pressure
sensor

oil grease kg lb 24 V DC 115 V AC 230 V AC

12389919 MLPI-4-1-24-IF103-PSE – • 4 9 • – – IF103 •


12389942 MLPI-4-1-24-24-PSE – • 4 9 • – – – •

12389937 MLPI-4-1-115-IF103-PSE – • 4 9 – • – IF103 •


12389944 MLPI-4-1-115-IF103-EPT – • 4 9 – • – IF103 –

12389912 MLPI-4-1-230-IF103-PSE – • 4 9 – – • IF103 •


12389925 MLPI-4-1-230-IF103-EPT – • 4 9 – – • IF103 –

12389936 MLPI-10-1-115-IF103-PSE – • 10 22 – • – IF103 •


12389943 MLPI-10-1-115-IF103-EPT – • 10 22 – • – IF103 –

12389916 MLPI-10-1-230-IF103-PSE – • 10 22 – – • IF103 •


12389924 MLPI-10-1-230-IF103-EPT – • 10 22 – – • IF103 –

12389954 MLPI-10-1-230-24-EPT – • 10 22 – – • – –

12389953 MLPI-10-OS-230-IF103-PSE • – 10 22 – – • IF103 •

1) Further MLPI versions available on request

Accessories
Control unit Control unit
Order number Designation Description

11500610 ST-102 ST-102 control center to be located in machinery cabin

79
Pump unit

P 653S
Pump units for grease

Description
Technical data
The fully integrated P 653S pump unit is an example of the Lincoln
Function principle electrically operated piston pump
brand's commitment to providing innovative, cost-effective solutions Outlets 1
through industry-leading advances in technology This next-genera- Metering quantity 24,6 cm 3/ min, 1.5 in 3/ min
tion, lower-cost pump package can be fitted with one of four reser- Lubricant grease up to NLGI 2
Operating temperature V DC: –40 to +70 °C, –40 to +158 °F V AC:
voir sizes and easily adapts to many applications It also interfaces 0 to +50 °C, +32 to +122 °F
with telematics technology in today’s heavy equipment A neutral Operating pressure pressure switch, fixed: 240 bar, 3 500 psi;
switch allows mobile equipment to remain idling with pump power pressure transducer, adjustable:
96 to 317 bar, 1 400 to 4 600 psi
on, but the timer is deactivated, allowing manual lubrication func- end of line pressure switch and transducer
tionality All pumps include low-level and system fault alarms Simply setting, not adjustable: 172 bar, 2 500 psi
mount the pump, connect the power and supply lines, and the sys- Reservoir 4; 8; 15 or 20 kg, 8.8; 18; 33 or 44 lb
Material (reservoir) thermoplastic
tem is ready for operation Connection outlet G 1/4
Incoming voltage DC: 19 to 31 V DC
AC: 100 to 240 V AC
Features and benefits Current DC: max 10 A
AC: max 1,7 A
• Integration of major system components reduces operation costs Frequency AC: 47 to 63 Hz
Pause time max 59 h, 59 min
• Plug-and-play pump design for reduced installation time min 4 min;
• Neutral switch ensures reduces grease consuption Pause time increments 1 hr or 1 min
• For use with metering devices of category 5, 6, 7 Pumping time max 12 min
Dimensions min 240 × 235 × 467 mm
max 240 × 235 × 800 mm
Applications min. 9.45 × 9.25 × 18.4 in
max. 9.45 × 9.25 × 31 in
• Renewable energy, construction machinery Mounting position vertical
• Mining and mineral processing, commercial vehicles
Pump elements
Piston ø 7 mm, 0.28 in
NOTE Number connected 3
Protection IP 6K9K
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

80
Pump unit

P 653S

Pump units for grease


Order information

Order number Operating voltage Reservoir Follower Internal Internal Internal and Internal and
capacity plate pressure pressure end-of-line end-of-line
switch transducer pressure switch pressure transducer

24 V DC 120/230 V AC kg lb

80086 • – 4 9 – • – – –
80087 • – 4 9 – – • – –
80105 • – 4 9 – – – • –
80106 • – 4 9 – – – – •
80076 • – 4 9 • • – – –

80077 • – 4 9 • – • – –
80109 • – 4 9 • – – • –
80110 • – 4 9 • – – – •
80090 • – 8 18 – • – – –
80091 • – 8 18 – – • – –

80107 • – 8 18 – – – • –
80108 • – 8 18 – – – – •
80080 • – 8 18 • • – – –
80081 • – 8 18 • – • – –
80111 • – 8 18 • – – • –

80112 • – 8 18 • – – – •
80121 • – 15 33 • – • – –
80122 • – 15 33 – – • – –
80120 • – 20 44 – – • – –

80083 – • 4 9 – – • – –
80084 – • 4 9 – – – • –

80085 – • 4 9 – – – – •
80072 – • 4 9 • • – – –
80073 – • 4 9 • – • – –
80074 – • 4 9 • – – • –
80075 – • 4 9 • – – – •

80088 – • 8 18 – • – – –
80089 – • 8 18 – – • – –
80078 – • 8 18 • • – – –
80079 – • 8 18 • – • – –
80134 – • 15 33 – – • – –

80135 – • 20 44 • – – – •

Note: All models are designed for grease and include stirring paddle and low-level detection Pumps include remote signaling cable, relief valve,electrical connectors and external pressure switch
or transducer (as indicated for each model)

81
Pump unit

E-PUMP
Pump units for grease

Description
Technical data
The electrical barrel pumping unit E-PUMP is a versatile barrel
pump and it is especially designed for pumping oil or grease lubri- Function principle electrically operated pump
Outlets 1
cants up to NLGI grade 2 into a centralized lubrication system When Number of pump elements 4
equipped with a change-over valve unit, as E-VALV e g or a shut-off Metering quantity 55 g/min; 0.3880136 oz/min
valve as E-VALVE-S e g it can be used either in single-line, dual-line Operating temperature –30 to +70 °C, -20 to 160 °F
Operating pressure max 240 bar, 3 480 psi
or progressive lubrication systems A complete pumping center con- Lubricant grease up to NLGI 2
sists of a pumping unit and a lid set EPUMP-XXX-ECO coding is oil up 40–1 000 mm2/s
Operating voltage 20–32 V DC
referring to ECO lid sets (descending pump head with follower plate),
Power consumption 150 W
which are suitable for greases in NLGI grades 1 and 2 while EPUMP- Heater 40W / 24V, heater resistor
XXX-STA coding is referring to STA lid sets (pump head always at for pump elements in ECO models
Display LED’s 5 yellow, 1 green, 1 red
barrel bottom), which are suitable for oil or greases in NLGI 0, 00 Drum capacity 18, 50 and 180 kg, 40, 120 or 400 lb
and 000 classes drum not included
Pressure sensor 50-240 bar adjustable in 25 bar steps
725.1 to 3480.9 psi in 362.6 psi steps
Features and benefits Protection class IP 65
Dimensions depending on the model
• EPUMP models reflecting typical and often used barrel sizes min 400 × 400 × 800 mm
max 400 × 400 × 1 300 mm
• Compact electrically operated pump for applications where no min. 15.75 × 15.75 × 31.49 in
max. 15.75 × 15.75 × 51.18 in
air supply is available Mounting position vertical
• An internal pressure control and a heating element secure the
pump’s function in high-pressure conditions and cold climates

Applications
• Heavy industries (paper, steel and other process industries)
NOTE
• Mining and mineral processing Further technical information, technical drawings,
• Machinery workshops accessories, spare parts or product function descriptions
available on SKF com/lubrication
• Food and beverage
• Cement industry

82
Pump unit

E-PUMP

Pump units for grease


Order information

Order number Designation Lubricant Control Suitable barrel size

kg lb

12375160 SKF-EPUMP-1/8-ECO-24-1 Grease up to NLGI 2 integrated control unit for single-line systems 18 40
12375080 SKF-EPUMP-1/4-ECO-24-1 Grease up to NLGI 2 integrated control unit for single-line systems 50 120
12375000 SKF-EPUMP-1/1-ECO-24-1 Grease up to NLGI 2 integrated control unit for single-line systems 180 400

12375200 SKF-EPUMP-1/8-STA-24-1 Oil up to 1 000 mm2/s integrated control unit for single-line systems 18 40
12375120 SKF-EPUMP-1/4-STA-24-1 Oil up to 1 000 mm2/s integrated control unit for single-line systems 50 120
12375040 SKF-EPUMP-1/1-STA-24-1 Oil up to 1 000 mm2/s integrated control unit for single-line systems 180 400

Accessories

Lid sets for grease barrels Lid sets for grease barrels

Order number Designation Lubricant for barrel size

kg lb

12381280 E-LIDSET-1/8-ECO Grease 18 40

12381285 E-LIDSET-1/4-ECO Grease 50 120

12381290 E-LIDSET-1/1-ECO Grease 180 400

Lid sets for oil Lid sets for oil barrels

Order number Designation Lubricant for barrel size

kg lb

12381292 E-LIDSET-1/8-STA Oil 18 40

12381294 E-LIDSET-1/4-STA Oil 50 120

12381296 E-LIDSET-1/1-STA Oil 180 400

83
Pump unit

FK
Pump units for grease

Description
Technical data
The FK pump unit is a multi-function piston pump with a versatile,
modular structure The FK pump unit can be used as a single-line, Function principle electrically operated
dual-line or progressive pump unit with or without integrated piston pump
Outlets 1
reversing valves The modular structure of the pump also allows Metering quantity 12,3 to 74 cm 3/min
it to be retrofitted from one of the above-mentioned lubrication sys- 0.75 to 4.5 in 3/min
Lubricant mineral oils or environmentally
tems to another system without much effort or expense The pump, compatible oils from ISO VG 46 to
which was designed to handle demanding usage, is available with greases of NLGI Class 2
reservoir sizes of 15 kg (33 lb), 30 kg (66 lb) and 60 kg (132 lb) (consultation required for synthetic oils)
Operating temperature -25 to +60 °C, -13 to +140 °F
Operating pressure max 400 bar, 5 800 psi
Features and benefits Reservoir 15; 30 or 60 kg
33, 66 or 132 lb
• Versatile, modular system; easy to retrofit to other systems Material steel-sheet housing, steel, aluminum
• High functional reliability due to positively driven pistons Operating voltage 230/400 V AC
Pumping elements 1 to 6
• Fill-level monitoring (using ultrasonic sensor) Filling method via filler socket G 1/2
with two adjustable switching points Gear type screw drive, type 1M
Gear ratio 40:1
Nominal speed 1 500 rpm
Applications Frequency 50 Hz
Nominal output 0,37 kW
• Automotive industry Rated current 1,09 A
• Rotary applications Protection IP 55-F
• Assembly lines Connection outlet G 1/2
Dimensions:
• Printing presses 15 kg, 33 lb max 470 × 598 × 335 mm
max. 18.5 × 23.54 × 13.18 in
30 kg, 66 lb max 665 × 598 × 335 mm
max. 26.2 × 23.54 × 13.18 in
60 kg, 132 lb max 1 035 × 598 × 335 mm
max. 40.74 × 23.54 × 13.18 in
NOTE Mounting position vertical
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-3033-EN, 951-170-200-EN
3D
skf-lubrication partcommunity com/3d-cad-models

84
Pump unit

FK

Pump units for grease


Identification code FK – 1M 04 – – – AF 07

Product series

Version
1= Unit for single-line centralized lubrication
systems
2 = Unit for dual-line centralized lubrication
systems with change-over valves
3 = Unit for dual-line centralized lubrication
systems without change-over valves
4 = Unit for progressive systems
Lubricant reservoir
15 = 15 kg, 33 lb
30 = 30 kg, 66 lb
60 = 60 kg, 132 lb
Monitoring
X = Without lubricant level monitoring
U2 = Ultrasonic sensor with 2 switching points
Drive type
1M = Electrically operated
Gear ratio
04 = 40:1
Metering quantity
1 = 0,67 kg/h, 12.3 cm 3/min. 2 = 1,34 kg/h, 24.7 cm 3/min.
3 = 2,00 kg/h, 37.0 cm 3/min. 4 = 2,64 kg/h, 49.3 cm 3/min.
5 = 3,34 kg/h, 61.7 cm 3/min. 6 = 4,00 kg/h, 74.0 cm 3/min.
Pressure-regulating valve, factory-set to
200 = 200 bar, 2 900 psi (for progressive, single-line and dual-line centralized lubrication systems)
300 = 300 bar, 4 350 psi (for progressive, single-line and dual-line centralized lubrication systems)
Pressure gauge
/ = Without pressure gauge
MA = 1x pressure gauge
M2 = 2x pressure gauge
Filler socket/screw cap
0 = Without filler
2 = Without filler socket, with screw cap
socket
3 = With filler socket and screw cap
1 = With filler socket
Version key
0001 = Basic design
4001 = Basic design with control cabinet and control unit (on request)
Motor data
AF = motor speed 1 500 rpm, rated voltage 230/400 V AC, 50 Hz
Motor protection class
07 = IP 55 F

85
Pump unit

FlowMaster, electric
Pump units for grease

Description
Technical data
The high-performance FlowMaster product line is a new generation
of pump technology Compact and versatile, its unique rotary drive Function principle electrically operated piston pump
and modular gear set let you adjust the speed of the pump's motor to Outlets 1
Metering quantity max 103 cm 3/min
exactly fit your application FlowMaster pumps can save the cost of max. 6.3 in 3/min
air and plug in 12/24 V DC, 120/230-1ph and 230/460-3ph V AC Lubricant grease NLGI Grade 0, 1, 2
Operating temperature –40 to +65 °C; –40 to +150 °F
models The motion of pump created by the electric rotary motor is Operating pressure:
converted into reciprocating pump motion, providing an efficient 12 V DC max 251 bar; 3 500 psi
lubricant flow Because of its rotary drive, the motor can be placed 24 V DC max 345 bar; 5 000 psi
120 to 460 V AC max 345 bar; 5 000 psi
directly on the pump As a result, the pump is so compact it fits Operating voltage 12/24 V DC; 120 to 460 V AC
almost anywhere Reservoir 40, 55, 180 kg; 90, 120, 400 lb
Material fluoroelastomer, polyurethane, steel,
aluminum zinc casting
Features and benefits Connection outlet 1/4 NPTF
Gear ratio 17 8:1; 19:1; 34:1
• Advanced technology: brushless DC motor Nominal power 5 to 50 and 9,5 to 100 rpm
• Temperature and overload protection: durable and Electric current:
long-lasting product that reduces machinery downtime 12/24 V DC 1 to 7 5 A
120 V AC 1 to 4 6 A
for maintenance; less repair costs 230-460 V AC 0,5 to 2,4 A
• Totally sealed: withstands washdowns
• For use with metering devices of category 5, 6 and 7 Dimensions:
16, 25, 28, 35, 40 kg 360 × 350 × 170 mm
35, 55, 60, 78, 90 lb 14.17 × 13.78 × 6.7 in
Applications 55 kg 408 × 223 × 946 mm
120 lb 16.07 × 8.78 × 37.24 in
• Mining and mineral processing, construction machinery 180 kg 408 × 223 × 1 111 mm
• Steel mills, paper mills, food and beverage 400 lb 16.07 × 8.78 × 43.24 in
Mounting position vertical

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
12938-EN
3D
skf-lubrication partcommunity com/3d-cad-models

86
Pump unit

FlowMaster, electric

Pump units for grease


Order information

Order Designation Power Reservoir capacity Ratio Metering quantity Operating Speed
number min. max. pressure max.

kg lb cm 3/min in 3/min cm 3/min in 3/min bar psi rpm

85479 pump, follower, 24 V DC 28 60 19:01 11,5 0.7 103 6.3 170 2 500 9,5-100
bucket cover,
hardware

85728 reservoir and pump 24 V DC 28 60 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85729 reservoir and pump 24 V DC 90 41 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85730 reservoir and pump 24 V DC 120 55 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100

85736 pump 24 V DC 16 35 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85737 pump 24 V DC 28 60 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85738 pump 24 V DC 55/40 120/90 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85739 pump 24 V DC 180 400 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85740 pump 24 V DC 25 55 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85743 pump 115 to 230 V AC 55/40 120/90 19:1 11,5 0.7 103 6.3 345 5 000 95
85744 pump 115 to 230 V AC 180 400 19:1 11,5 0.7 103 6.3 345 5 000 95
85745 pump 220 to 420 V AC, 55/40 120/90 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
50 Hz, 3 ph
85746 pump 220 to 420 V AC, 180 400 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100
50 Hz, 3 ph
85747 pump 24 V DC 0:00 35 17 8:1 11,5 0.7 103 6.3 170 5 000 9,5-100
85748 pump 24 V DC 16 35 34:1 6,55 0.4 57,4 3.5 345 5 000 May-50
85749 pump 24 V DC 55/40 120/90 34:1 6,55 0.4 57,4 3.5 345 5 000 May-50
85750 pump 24 V DC 16 35 7:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85751 pump 24 V DC 16 35 7:1 11,5 0.7 103 6.3 345 5 000 9,5-100
85752 pump 12 V DC 16 35 19:1 11,5 0.7 103 6.3 170 2 500 9,5-100
85753 pump 12 V DC 16 35 19:1 11,5 0.7 103 6.3 170 2 500 9,5-100
85754 pump 12 V DC 28 60 19:1 11,5 0.7 103 6.3 345 5 000 9,5-100

Accessory
Drum cover, follower assembly, vent valve etc
Order number Designation Reservoir capacity

gal lb

85474 drum cover 18 120


85492 follower assembly
85664 vent valve assembly (24 V DC)
272180 strainer

85475 drum cover 55 400


270982 follower assembly
85665 vent valve assembly
272180 strainer

274899 24 V DC vent valve, IP 67 explosion-proof rating


276325 24 V DC vent valve, IP 65 rating
276903 24 V DC vent valve, IP 65 rating
276919 hardware kit for 276903
525-32083-1 24 V DC vent valve, IP 54 rating

87
Metering devices for oil

88
Overview of oil and fluid grease metering devices

Metering devices for oil


Single-line metering devices

Product Cate- Lubricant Metering quantity Operating pressure Relief pressure Adjustable Function type Page
gory 1) max metering
quantity

oil fluid grease cm3/stroke in3/stroke bar psi bar psi

341 2) 1 • – 0,01-0,16 0.0006-0.0097 6-80 87-1 160 1 3) 43.5 – prelubrication 90


340 1 • – 0,01-0,16 0.0006-0.0097 6-80 87-1 160 1 3) 43.5 – prelubrication 92
LS22 2) 1 • – 0,01-0,16 0.0006-0.0097 12-20 174-290 3 43.5 – prelubrication 94
LS21 2) 1 • – 0,025-0,5 0.0015-0.0305 12-80 174-1 160 3 43.5 • prelubrication 95
361 1 • – 0,02-0,10 0.0010-0.0060 8-40 116-1 160 1 14.5 – dynamic pulse 96
type
351 2) 1 • – 0,05-0,60 0.0030-0.0366 6-80 87-1 160 1 14.5 – prelubrication 100
350 1 • – 0,05-0,60 0.0030-0.0366 6-80 87-1 160 1 14.5 – prelubrication 102
370 1 • – 0,05-1,50 0.0030-0.0915 20-80 290-1 160 1 14.5 – relubrication 104
391 1 • – 0,20-1,50 0.0122-0.0915 8-45 116-653 1 14.5 – prelubrication 106
390 1 • – 0,20-1,50 0.0122-0.0915 8-80 116-1 160 1 14.5 – prelubrication 108

321 G, 2 • • 0,01-0,10 0.0006-0.0060 12-45 174-653 3 43 5 – special assembly 110


T, W, arrangement
Modul
321 G4, 2 • • 0,03-0,10 0.0118-0.0060 12-45 174-653 3 43 5 – special assembly 110
arrangement
361 2 • • 0,01-0,20 0.0006-0.0122 8-80 116-1 160 3 43.5 – dynamic pulse 96
type
321 G7 2 • • 0,01-0,30 0.0006-0.0183 12-45 174-653 3 43.5 – special assembly 110
arrangement

AB 2) 2 • • 0,01-0,60 0.0006-0.0366 18-50 261-725 3 43.5 – prelubrication 112


341 2 • • 0,03-0,10 0.0018-0.0061 6-80 87-1 160 3 43.5 – prelubrication 90
340 2 • • 0,03-0,10 0.0018-0.0061 6-80 87-1 160 3 43.5 – prelubrication 92
310 2 • • 0,03-0,16 0.0018-0.0097 12-38 174-551 3 43.5 – prelubrication 98
VN 2 – • 0,05-1,00 0.0030-0.0610 20-80 290-1 160 1 14.5 – relubrication 114
351 2 • • 0,10-0,60 0.0061-0.0366 6-80 87-1 160 3 43.5 – prelubrication 100
350 2 • • 0,10-0,60 0.0061-0.0366 6-80 87-1 160 3 43.5 – prelubrication 102

Oi-Al-SR 3 • • 0,02-0,10 0.0012-0.0061 30-100 435-1 450 5 72.5 – cartridge 116


arrangement

391 3 • • 0,10-0,30 0.0061-0.0183 8-45 116-653 7 101.5 – prelubrication 106


390 3 • • 0,10-0,30 0.0061-0.0183 8-45 116-653 7 101.5 – prelubrication 108

SL-42 4 • • 0,016-0,049 0.001-0.0029 52-69 750-1 000 10 150 • prelubrication 118


SL-43 4 • • 0,016-0,131 0.001-0.0080 52-69 750-1 000 10 150 • prelubrication 120
SL-41 4 • • 0,13-1,31 0.0079-0.0799 52-69 750-1 000 10 150 • prelubrication 122
SL-44 4 • • 0,13-1,31 0.0079-0.0799 52-69 750-1 000 10 150 • prelubrication 124

1) The category allows a simple assignment of the metering device to a pump of the same category The category results from the relief pressure, the operating principle
and the lubricant suitable for the metering device
2) Stainless steel or C5M available
3) For the metering quantity version 0,01 cm3 and 0,02 cm3 max relief pressure is 3 bar

89
Metering device
Metering devices for oil

341

Description
Technical data
Developed for installation in manifolds, series 341 single-port,
Function principle Metering device
prelubrication metering devices are suitable for use with single-line, Outlets 1
centralized lubrication systems for oil and fluid grease The combina- Metering quantity oil: 0,01 to 0,16 cm 3
tion of these metering devices with one- to six-port manifolds pro- 0.0006 to 0.0097 in 3
fluid grease: 0,03 to 0,10 cm 3
vides flexible options for lubrication system design Manifolds cus- 0.0018 to 0.0061 in 3
tomized for product series 341 are available in aluminum and Lubricant mineral and synthetic oil,
stainless steel 20 to 2 000 mm 2/s,
0.031 to 3.100 in 2/s
fluid grease of NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to 176 °F
Features and benefits Operating pressure min 6 bar, 87 psi
max 80 bar, 1 160 psi
• Suitable with manifolds having one to six ports Relief pressure 1) max 3 bar, 43.5 psi
to match number of lubrication points Materials steel (galvanized, Cr6-free),
stainless steel, nickel-plated brass,
• Provides flexible options for systems with remote single brass, copper, FKM (FPM)/ NBR
lubrication points or multiple-port metering devices with Connection main line pipe ø 6 to 10 mm, solderless pipe
connection for threads
up to six ports G 1/8; G 1/4; M 10 × 1 or M 14 × 1,5
Connection outlet pipe ø 2,5 mm and ø 4 mm;
• Select optional push-in or screw-in type metering metering nipple (VS) with SKF Quick
nipples for feed line connections via order code Connector, metering nipple (00) for
solderless pipe connection
• Choose separately manifold models with different Dimensions min 43,5 × 12 mm; 1.713 × 0.472 in
thread sizes for main line connection and materials max 53 × 12 mm; 2.086 × 0.472 in
Mounting position any
• Current metering nipples above 0,03 cm3 are exchangeable 1) For oil metering quantity version 0,01 cm3 and 0,02 cm3 max relief pressure is 3 bar
to yield different output quantities

Applications NOTE
• Machine tools Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Printing machines
available on SKF com/lubrication:
• Packaging industry 1-5001-EN
• Textile industry 3D
skf-lubrication partcommunity com/3d-cad-models

90
Metering device

Metering devices for oil


341
Identification code 3 4 1 – – 0 0 0 0 – 0 0

Product series

Number of metering points (1)

Design and metering quantity

Design code 2 4 8 5 9 1 7 6
Lubricant Oil Oil Oil Fluid grease Fluid grease Oil Fluid grease Oil
ø Outlet [mm] 2,5 4 4 4 4 4 4 4
Distributor body Steel Steel Steel Steel Steel Steel Steel Steel (1 4305)
Metering nipple Brass Brass Brass Brass (n p ) Brass (n p ) Brass Brass (n p ) Steel (1 4305)
Elastomer NBR NBR KFM (FPM) NBR FKM (FPM) NBR NBR FKM (FPM)
Threaded seal FW 2) FW 2) FW 2) FW 2) Flat O-ring 3) O-ring 3) O-ring 3)
Connection outlet 00 VS 00 VS 00 VS 00 00 VS 00 VS 00 00

0,01 cm 3 1) 1 1 1 1 1 – – – 1 1 – – 1
0,02 cm 3 1) – – 6 – 6 – – – – 6 – – –
quantity code

0,03 cm 3 2 2 2 2 2 2 2 2 2 2 2 2 2
Metering

0,06 cm 3 3 3 3 3 3 3 3 3 3 3 3 3 3
0,10 cm 3 4 4 4 4 4 4 4 4 4 4 4 4 4
0,16 cm 3 5 5 5 5 5 – – – 5 5 – – 5
1) Subsequent modification of the metering quantity is not technically possible
2) FW=Flat washer must be ordered separately Order number: DIN7603-A8×11 5-CU
3) O-ring is part of the shipment

Accessory

Manifold
Manifold VL
Identification code V L –
Product series

Number of ports
01 = 1 screw-in point 04 = 4 screw-in points
02 = 2 screw-in points 05 = 5 screw-in points
03 = 3 screw-in points 06 = 6 screw-in points
(other numbers of ports available on request)
Description
Design of metering device pipe thread
For 341 metering devices, VL-manifolds are A = Normal profile, M8x1 with counterbore for O-ring
utilized for one to six screw-in points with D = Small profile, M8x1 without counterbore
thread M8x1 mm for O-ring or flat (copper) Material
washer sealing Normal-profile manifolds A = Aluminum E = Stainless steel (1 4305) (can only be selected for normal profile)
are available in aluminum and stainless
steel, while narrow-profile manifolds are Design of main line connection
G1 = G 1/8 per DIN 3852-2, Form X, small M4 = M14x1,5 with counterbore for
offered in aluminum only G2 = G 1/4 per DIN 3852-2, Form X, small solderless pipe connection per DIN 3862
M3 = M10x1 with counterbore for solderless (can only be selected for normal profile)
pipe connection per DIN 3862
91
Metering device
Metering devices for oil

340

Description
Technical data
Offered in two-, three- and five-port models, series 340 metering
Function principle metering device
devices were developed for use with single-line, centralized lubrica- Outlets 2, 3 or 5
tion systems for oil and fluid grease These metering devices are Metering quantity oil: 0,01 to 0,16 cm 3
designed for installation directly on the machine/system requiring 0.0006 to 0.0097 in 3
grease: 0,03 to 0,10 cm 3
lubrication Series 340 metering devices can be ordered with 0.0018 to 0.0061 in 3
fittings for the main line connection by selecting the appropriate Lubricant mineral and synthetic oil,
order code 20 to 2 000 mm 2/s and
fluid grease NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to +176 °F
Operating pressure min 6 bar, 87 psi;
Features and benefits max 80 bar, 1 160 psi
Relief pressure 1) max 3 bar, 43.5 psi
• Designed for installation directly Materials zinc die-cast, brass (oil),
on the machine/system requiring lubrication nickel-plated brass (fluid grease),
copper, steel, FKM (FPM)/NBR
• Select optional push-in or screw-in type metering Connection main line different fittings for pipe ø 6 to 10 mm
nipples for feed line connections or closure plugs for thread M 10×1
Connection outlet pipe ø2,5 and ø 4 mm metering
• Choose optional push-in or screw-in type main line fittings nipple (VS) with SKF quick connector,
metering nipple (00) for solderless
• Metering nipples above 0,03 cm3 are exchangeable to yield pipe connection
different output quantities Dimensions min 48 × 53 × 15 mm
max 99 × 58 × 15 mm
min. 1.889 × 2.086 × 0.590 in
max. 3.897 × 2.283 × 0.590 in
Applications Mounting position any
1) For oil metering quantity version 0,01 cm3 and 0,02 cm3 max relief pressure is 3 bar
• Machine tools
• Printing machines
• Packaging industry
NOTE
• Textile industry Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

92
Metering device

Metering devices for oil


340
Identification code 3 4 – – –

Product series

Number of metering points (2, 3, 5)

Design and metering quantity Fittings for main line connection


ø main line
Design code 2 4 8 5 Designation [mm] Code
Lubricant Oil Oil Oil Fluid grease
6 B
ø Outlet [mm] 2,5 4 4 4 Straight adapter
8 C
DIN 3862 with flat washer 1)
10 D
Metering nipple Brass Brass Brass Brass (n.p.)
Banjo fitting DIN 3862
6 F
Elastomer NBR NBR FKM (FPM) NBR with flat washer, lockable 1) 2)
Screw plug with flat washer – H
Connection outlet 00 VS 00 VS 00 VS 00
6 M
Straight adapter
0,01 cm 3 1) 1 1 1 1 1 – – 8 N
with EO-2 functional nut
0,02 cm 3 1) – – 6 – 6 – – 10 P
0,03 cm 3 2 2 2 2 2 2 2 Straight adapter 6 T
quantity code

0,06 cm 3 3 3 3 3 3 3 3 with SKF Quick Connector 8 U


Metering

0,10 cm 3 4 4 4 4 4 4 4 Banjo fitting with


6 V
0,16 cm 3 5 5 5 5 5 – – SKF Quick Connectors, not lockable
closed 2) V V V V V V V Vent plug with profile sealing ring – Y
Without fitting;
6 Z
for solderless pipe connection 1)
1) Subsequent modification of the metering quantity is not technically possible 1) Solderless pipe connection according to DIN 3862 (operating pressure max 45 bar)
2) V = Metering quatity of 0,03 cm 3, closed 2) Banjo bolt only inserted in delivery condition, not tightened

Accessory

Exchangeable metering nipples


Solderless pipe Order numbers for solderless pipe connection metering nipples
connection Outlet ø Elastomer Lubricant Order numbers sorted by metering quantity

0,03 cm 3 0,06 cm 3 0,10 cm 3 0,16 cm 3


mm in 0.00183 in 3 0.00366 in 3 0.0061 in 3 0.0097 in 3
2,5 0.10 NBR oil 995-994-003 995-994-006 995-994-010 995-994-016
4 0.16 NBR oil 995-994-103 995-994-106 995-994-110 995-994-116
4 0.16 NBR oil 341-453-K-S8 341-456-K-S8 341-460-K-S8 341-466-K-S8
4 0.16 NBR fluid grease 341-853-K 341-856-K 341-860-K –

SKF Quick Order numbers for SKF Quick Connector metering nipples
Connector Outlet ø Elastomer Lubricant Order numbers sorted by metering quantity

0,03 cm 3 0,06 cm 3 0,10 cm 3 0,16 cm 3


mm in 0.00183 in 3 0.00366 in 3 0.0061 in 3 0.0097 in 3
4 0.16 NBR oil 995-994-103-VS 995-994-106-VS 995-994-110-VS 995-994-116-VS
4 0.16 FKM oil 341-453-S8-VS 341-456-S8-VS 341-460-S8-VS 341-466-S8-VS
4 0.16 NBR fluid grease 341-853-VS 341-856-VS 341-860-VS –

93
Metering device
Metering devices for oil

LS22

Description
Technical data
Developed for installation in manifolds, LS22 are single-port meter-
ing devices for oil and special lubricants When used in combination Function principle metering device
with one- to five-port manifolds, these prelubrication metering Outlets 1
Metering quantity 0,010 to 0,160 cm 3
devices provide flexible options for lubrication system design 0.0006 to 0.0097 in 3
Connections with or without (M8x1) a quick-release connector Lubricant mineral and synthetic oil,
5 to 2 500 mm 2/s; 0.007 to 3.875 in 2/s
are offered for feed lines and connections with a quick-release or LDTS1 (dry film lubricant with
connector are available for main line tubes synthetic oil and PTFE additions)
Operating temperature 0 to +50 °C; +32 to +122 °F
Operating pressure min 12 bar; 174 psi
Features and benefits max 20 bar; 290 psi
Relief pressure max 3 bar; 43.5 psi
• For use with manifolds having one to five ports to
Materials stainless steel 303, FKM (FPM),
match number of lubrication points high phosphorus FDA
• Compatible with ø 4 mm for feed lines and ø 8 for main lines chem nickel-plated brass
Connection main line push-in connectors for pipe ø 8 mm
• Suitable for push-in or screw-in type fittings for dosers and thread G 1/4
and push-in type fittings for manifolds Connection outlet with or without push-in connectors
• Robust, reliable for pipe ø 4 mm and thread M 10x1
Dimensions min 89 × 68,5 × 20 mm
• Suitable for up to 200 lubrication points max 179 × 84 × 20 mm
min. 3.5 × 2.67 × 0.8 in
max. 7.0 × 3.3 × 0.8 in
Applications Mounting position any
• Conveyor chain surfaces and guides
• Food and beverage
• Packaging

Order information NOTE


Order number Outlet(s)
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
LS2210 1 available on SKF com/lubrication:
LS2220 2 15848 EN
LS2230 3
LS2240 4 3D
LS2250 5
skf-lubrication partcommunity com/3d-cad-models

94
Metering device

Metering devices for oil


LS21

Description
Technical data
Developed for installation in manifolds, LS21 are single-port meter-
ing devices for oil and special lubricants When used in combination Function principle Adjustable metering device
with one- to five-port manifolds, these adjustable prelubrication Outlets 1
Metering quantity adjustable 0,025 to 0,5 cm 3
metering devices provide flexible options for lubrication system 0.0015 to 0.0305 in 3
design Connections with or without (M8x1) a quick-release connec- Lubricant mineral and synthetic oil,
5 to 2 500 mm 2/s; 0.007 to 3.875 in 2/s
tor are offered for feed lines, and connections with a quick-release or LDTS1 (dry film lubricant with
connector are available for main line tubes synthetic oil and PTFE additions)
Operating temperature 0 to +50 °C; +32 to +122 °F
Operating pressure min 12 bar; 174 psi
Features and benefits max 20 bar; 290 psi
Relief pressure max 3 bar; 43.5 psi
• For use with manifolds having one to five ports
Materials stainless steel 303, FKM (FPM),
to match number of lubrication points high phosphorus FDA
• Compatible with ø 4 mm for feedlines and ø 8 for main lines chem nickel-plated brass
Connection main line push-in connectors for pipe ø 8 mm
• Suitable for push-in type fittings for dosers and manifolds and thread G 1/4
• Robust, reliable Connection outlet with or without push-in connectors
• Suitable for up to 200 lubrication points for pipe ø 4 mm and thread M 10x1
Working frequency ≤ 1 stroke/2 s
Dimensions min 89 × 92 × 20 mm
Applications max 179 × 110 × 20 mm
min. 3.5 × 3.622 × 0.8 in
• Conveyor chain surfaces and guides max. 7.0 × 4.330 × 0.8 in
• Food and beverage Mounting position any
• Packaging

Order information NOTE


Order number Outlet(s)
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
LS2110 1 available on SKF com/lubrication:
LS2120 2 15848 EN
LS2130 3
LS2140 4 3D
LS2150 5
skf-lubrication partcommunity com/3d-cad-models

95
Metering device
Metering devices for oil

361

Description
Technical data
Designed for installation in manifolds, series 361 single-port,
Function principle metering device
dynamic metering devices were developed for use with single-line, Outlets 1
centralized lubrication systems for oil and fluid grease When used in Metering quantity oil and fluid grease:
combination with one- to six-port manifolds, these metering devices 0,01 to 0,20 cm 3; 0.0006 to 0.012 in 3
synthetic oil:
provide flexible options for lubrication system design Customized 0,02 to 0,10 cm 3; 0.001 to 0.006 in 3
manifolds for series 361 metering devices are available in aluminum Lubricant mineral and synthetic oil:
10 to 1 000 mm 2/s, 0.015 to 1.55 in 2/s
fluid grease of NLGI 000, 00
Features and benefits Operating temperature 0 to +80 °C; +32 to +176 °F
Operating pressure min 8 bar, 116 psi
max 80 bar, 1 160 psi
• For use with manifolds having one to six ports
Relief pressure max 3 bar; 43.5 psi
to match number of lubrication points Materials steel (galvanized, Cr6-free),
(oil, grease), brass (oil), copper,
• Designed for installation directly on the machine/ flat washer (copper), NBR
system requiring lubrication Connection main line pipe ø 6 to 12 mm, 0.236 to 0.472 in;
solderless pipe connection for threads
• Select screw-in type distributor with feed line connections G 1/8; G 1/4; M 10×1 or M 14×1,5
via order code (DIN 3862)
Connection outlet pipe ø 4 mm straight
• Choose separately optional manifold models with compression nut fitting
different thread sizes for main line connection Dimensions min 42 × 14 mm
max 46,5 × 14 mm
min. 1.653 × 0.551 in
max. 1.830 × 0.551 in
Applications Mounting position any

• Chain lubrication
• Transport and conveyor belts

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

96
Metering device

Metering devices for oil


361
Identification code 3 6 1 – 0 0 – 0 0 0 0 – 0 0

Product series

Number of metering points (1)

Design and metering quantity

Design code 1 2
Lubricant Oil, fluid grease Oil
ø Outlet [mm] 4 4
Distributor body Steel, galvanized Brass
Metering nipple Steel, galvanized Brass
Elastomer NBR NBR
Connection outlet 00 00

0,01 cm 3 1 –
0,02 cm 3 2 2
quantity code

0,03 cm 3 3 3
Metering

0,05 cm 3 4 4
0,10 cm 3 5 5
0,20 cm 3 6 –

Flat washer must be ordered separately Order number: 504-019

Accessory

Manifold
Manifold VL
Identification code V L –

Product series

Number of ports
01 = 1 screw-in point 04 = 4 screw-in points
02 = 2 screw-in points 05 = 5 screw-in points
03 = 3 screw-in points 06 = 6 screw-in points
(other numbers of ports available on request)
Description
Design of metering device pipe thread
For 361 metering devices, VL-manifolds
B = Normal profile, M 10×1 with counterbore for flat washer or O-ring
are utilized for one to six screw-in points
with thread M 10×1 mm for flat washer Material
sealing Various main line connections A = Aluminum E = Stainless steel (1 4305) (can only be selected for normal profile)
can be selected via order code Design of main line connection
G1 = G 1/8 per DIN 3852-2, Form X, small M4 = M14x1,5 with counterbore for solder-
G2 = G 1/4 per DIN 3852-2, Form X, small less pipe connection per DIN 3862 (can only
M3 = M10x1 with counterbore for solderless pipe be selected for normal profile)
connection per DIN 3862

97
Metering device
Metering devices for oil

310

Description
Technical data
As the industry’s first non-metallic metering device, SKF’s Series 310
Function principle metering device
has a unique appearance However, its sleek, contemporary design Outlets 2, 3 or 5
provides proven SKF reliability for a minimum of 400 000 lubrication Metering quantity 0,03 to 0,16 cm 3
cycles Developed for pre-lubrication applications using oil and fluid 0.0018 to 0.0097 in 3
Lubricant mineral and synthetic oil,
grease, this metering device is simple to install utilizing plastic or 20 to 1 500 mm 2/s
metallic lines and can be mounted in either an upright or inverted fluid grease: NLGI 00 and 000
position It also features easily identiiable dosing elements to meet Operating temperature +5 to +50 °C; +41 to +122 °F
Operating pressure min 12 bar, 174 psi
various lubrication requirements max 38 bar, 551 psi
Relief pressure max 3 bar; 43.5 psi
Materials high-performance PA66 resin
Features and benefits Connection main line fittings for ø 6 mm lines
Connection outlet fittings for ø 4 mm lines
• Suitable for use with plastic tubes or metal pipes Dimensions min 68 × 70 ×20,5 mm
max 119 × 70 ×20,5 mm
• Color-coded dosing elements to identify lubricant volumes min. 2.67 × 2.75 × 8.07 in
max. 4.68 × 2.75 × 8.07 in
• Provides precise metering of lubricant Mounting position any
• Simple, lexible machine mounting in any position
• 2-, 3- or 5-port manifolds available
• Suitable for oil and fluid grease

Applications
• Machine tools
• Textile and wood industry
• Printing machines NOTE
Further technical information, technical drawings,
• Conveyors
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
17505 EN
3D
skf-lubrication partcommunity com/3d-cad-models

98
Metering device

Metering devices for oil


310
Identification code 3 1 – 8 0 0 – – 0 0

Product series

Number of metering points


2 = 2 outlets
3 = 3 outlets
5 = 5 outlets
Elastomer

Outlet 5 2)
Outlet 4 2)
Outlet 3 1)
Outlet 2
Outlet 1
8 = Elastomer (FPM)

Metering quantity
0 = no outlet
2 = blue; 0,03 cm 3; 0.0018 in 3
3 = white; 0,06 cm 3; 0.0036 in 3
4 = grey; 0,10 cm 3; 0.0061 in 3
5 = black; 0,16 cm 3 ; 0.0097 in 3
Y = grey; closed; blind plug
Connection main line
B = ø6 mm
Y = closed (with #898-210-001)

1) Not available for 2-outlet manifold 312 = 0


2) Not available for 2- and 3-outlet manifold 312 = 0; 313 = 0

Accessory

End-of-line plug
Description
End-of-line plug End-of-line plug
End-of-line plug suitable to plug main line
Order number Description
outlet of 310 metering device to close the
lubrication system The red colour singalizes
898-210-001 End-of-main-line the end of the lubrication system
plug

99
Metering device
Metering devices for oil

351

Description
Technical data
Designed for installation in manifolds, series 351 single-port, prelu-
Function principle metering device
brication metering devices were developed for use with single-line, Outlets 1
centralized lubrication systems for oil and fluid grease When used in Metering quantity oil: 0,05 to 0,60 cm 3
combination with one- to six-port manifolds, these metering devices 0.0030 to 0.0366 in 3
fluid grease: 0,10 to 0,60 cm 3
provide flexible options for lubrication system design Customized 0.0061 to 0.0366 in 3
manifolds for series 351 metering devices are available in aluminum Lubricant mineral and synthetic oil,
and stainless steel 20 to 2 000 mm 2/s and
fluid grease NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to +176 °F
Operating pressure min 6 bar, 87 psi
Features and benefits max 80 bar, 1 160 psi
Relief pressure max 3 bar, 43.5 psi
• For use with manifolds having one to six ports Materials aluminum, stainless steel, brass (oil),
to match number of lubrication points nickel-plated brass (grease),
flat washer (copper, stainless steel),
• Provides flexible options for systems with remote single FKM (FPM)/NBR
lubrication points or multiple-port metering devices with Connection main line pipe ø 6 to 12 mm solderless pipe
connection for threads G 1/8; G 1/4;
up to six ports M 10 × 1 or M 14 × 1,5 (DIN 3862)
Connection outlet pipe ø 4 mm metering nipple (VS) with
• Select optional push-in or screw-in type nipples for SKF Quick Connector - metering nipple
feed line connections (00) for solderless pipe connection
Dimensions min 43,5 × 12 mm; 1.713 × 0.472 in
• Choose separately manifold models with different max 53 × 12 mm; 2.086 × 0.472 in
thread sizes for main line connection and materials Mounting position any

• Current metering nipples are exchangeable to yield


different output quantities

Applications NOTE
• Machine tools Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Printing machines
available on SKF com/lubrication:
• Packaging industry 1-5001-EN
• Textile industry 3D
skf-lubrication partcommunity com/3d-cad-models

100
Metering device

Metering devices for oil


351
Identification code 3 5 1 – – 0 0 0 0 – 0 0

Product series

Number of metering points (1)

Design and metering quantity

Design code 0 8 4 1 7 2 3 6
Lubricant Oil Oil Oil Fluid grease Fluid grease Oil Fluid grease Oil
ø Outlet [mm] 4 4 4 4 4 4 4 4
Distributor body Aluminum Aluminum Steel (1 4305) Aluminum Aluminum Aluminum Aluminum Steel (1 4305)
Metering nipple Brass Brass Steel (1 4305) Brass (n p ) Brass (n p ) Brass Brass (n p ) Steel (1 4305)
Elastomer NBR FKM (FPM) FKM (FPM) NBR FKM (FPM) NBR NBR FKM (FPM)
Threaded seal FW 1) FW 1) Steel (1 4305) 2) FW 1) FW 1) O-ring 3) O-ring 3) O-ring 3)
Connection outlet VS 00 VS 00 00 VS 00 VS 00 VS 00 VS 00 00

0,05 cm 3 3 3 3 3 – – – – – – – – – –
0,10 cm 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4
quantity code

0,20 cm 3 5 5 5 5 5 5 5 5 5 5 5 5 5 5
Metering

0,30 cm 3 – – – – – 6 6 6 6 – – 6 6 –
0,40 cm 3 6 6 6 6 6 – – – – 6 6 – – 6
0,60 cm 3 7 7 7 7 7 – 7 – – 7 7 – – 7
1) FW=Flat washer must be ordered separately Order number: 504-019
2) Stainless steel ring must be ordered separately Order number: 99-1031-7603
3) O-ring is part of the shipment

Accessory

Manifold
Manifold VL
Identification code V L –
Product series

Number of ports
01 = 1 screw-in point 04 = 4 screw-in points
02 = 2 screw-in points 05 = 5 screw-in points
03 = 3 screw-in points 06 = 6 screw-in points
(other numbers of ports available on request)
Description
Design of metering device pipe thread
For 351 metering devices, VL-manifolds
B = Normal profile, M 10×1 with counterbore for flat washer or O-ring
are utilized for one to six screw-in points
with thread M 10×1 mm for O-ring or flat Material
(copper) washer sealing Various main line A = Aluminum E = Stainless steel (1 4305) (can only be selected for normal profile)
connections can be selected via order code Design of main line connection
G1 = G 1/8 per DIN 3852-2, Form X, small M4 = M14x1,5 with counterbore for solderless
G2 = G 1/4 per DIN 3852-2, Form X, small pipe connection per DIN 3862(can only
M3 = M10x1 with counterbore for solderless be selected for normal profile)
pipe connection per DIN 3862

101
Metering device
Metering devices for oil

350

Description
Technical data
Designed for installation directly on the machine/system requiring
Function principle metering device
lubrication, series 350 single-line, prelubrication metering devices Outlets 2, 3 or 5
are available in two-, three- and five-port models These metering Metering quantity oil: 0,05 to 0,60 cm 3
devices were developed for use with single-line, centralized lubrica- 0.003 to 0.037 in 3
grease: 0,10 to 0,60 cm 3
tion systems for oil and fluid grease Series 350 metering devices 0.0061 to 0.037 in 3
can be ordered with fittings for the main line connection by selecting Lubricant mineral and synthetic oil,
the appropriate order code 20 to 2 000 mm 2/s and
fluid grease NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to +176 °F
Operating pressure min 6 bar, 87 psi;
Features and benefits max 80 bar, 1 160 psi
Relief pressure max 3 bar, 43.5 psi
• For use with distributor bodies having two, three and Materials zinc die-cast, brass (oil), nickel-plated
five ports to match number of lubrication points brass (fluid grease), copper, steel,
FKM (FPM)/NBR
• Designed for installation directly on Connection main line different fittings for pipe ø 6 to 10 mm;
the machine/system requiring lubrication 0.236 to 0.393 in or closure plugs for
thread M 12×1
• Select push-in or screw-in type metering nipples for feed line Connection outlet pipe ø 4 mm metering nipple (VS) with
SKF Quick Connector - metering nipple
connection with metering device bodies (00) for solderless pipe connection
• Choose push-in or screw-in type main line fittings Dimensions min 46 × 83 × 18 mm
max 97 × 86 × 18 mm
with metering device bodies min. 1.811 × 3.267 × 0.708 in
max. 3.818 × 3.385 × 0.708 in
• Current metering nipples above 0,03 cm 3 are exchangeable Mounting position any
to yield different output quantities

Applications
• Machine tools NOTE
Further technical information, technical drawings,
• Printing machines
accessories, spare parts or product function descriptions
• Packaging industry available on SKF com/lubrication:
• Textile industry 1-5001-EN
• Agriculture 3D
skf-lubrication partcommunity com/3d-cad-models

102
Metering device

Metering devices for oil


350
Identification code 3 5 – – –

Product series

Number of metering points (2, 3, 5)

Design and metering quantity Fittings for main line connection


Main line
Design code 0 8 1 7 Designation [mm] Code
Lubricant Oil Oil Fluid grease Fluid grease 6 B
Straight adapter
ø Outlet [mm] 4 4 4 4 8 C
DIN 3862 with flat washer 1)
10 D
Metering nipple Brass Brass Brass (n.p.) Brass (n.p.) Banjo fitting DIN 3862 6 E
with flat washer, lockable 1) 2) 8 F
Elastomer NBR FKM (FPM) NBR FKM (FPM)
Screw plug with flat washer – H
Connection outlet VS 00 VS 00 VS 00 VS 00 6 M
Straight adapter 8 N
0,05 cm 3 3 3 3 3 – – – –
with EO-2 functional nut 10 P
0,10 cm 3 4 4 4 4 4 4 4 4
12 R
0,20 cm 3 5 5 5 5 5 5 5 5
quantity code

Straight adapter 6 S
0,30 cm 3 – – – – 6 6 6 6
with SKF Quick Connector 8 T
Metering

0,40 cm 3 6 6 6 6 – – – -
Banjo fitting with 6 W
0,60 cm 3 7 7 7 7 – 7 – – SKF Quick Connectors 8 X
closed* V V V V V V V V
Without fitting (M12x1 thread) – Z

1) Solderless pipe connection according to DIN 3862 (operating pressure max 45 bar)
V = Metering quatity of 0,20 cm 3, closed 2) Banjo bolt only inserted in delivery condition, not tightened

Accessory

Exchangeable metering nipples


Order numbers for metering nipples for oil (replaceable)
Outlet ø Material Metering Metering quantity
elastomer nipple
0,05 cm 3 0,10 cm 3 0,20 cm 3 0,40 cm 3 0,60 cm 3
mm in 0.003 in 3 0.006 in 3 0.012 in 3 0.024 in 3 0.036 in 3
4 0.16 NBR 00 352-005-K 352-010-K 352-020-K 352-040-K 352-060-K
4 0.16 NBR VS 352-005-VS 352-010-VS 352-020-VS 352-040-VS 352-060-VS
4 0.16 FKM (FPM) 00 352-005-K-S8 352-010-K-S8 352-020-K-S8 352-040-K-S8 352-060-K-S8
4 0.16 FKM (FPM) VS 352-005-S8-VS 352-010-S8-VS 352-020-S8-VS 352-040-S8-VS 352-060-S8-VS

Order numbers for metering nipples for fluid grease (replaceable)


Outlet ø Material Metering Metering quantity
elastomer nipple
0,10 cm 3 0,20 cm 3 0,30 cm 3 0,60 cm 3
mm in 0.006 in 3 0.012 in 3 0.018 in 3 0.036 in 3
4 0.16 NBR 00 995-993-610 995-993-620 995-993-630 995-993-660
4 0.16 NBR VS 995-993-610-VS 995-993-620-VS 995-993-630-VS –
4 0.16 FKM (FPM) 00 352-010-K-S82 352-020-K-S82 352-030-K-S82 –
4 0.16 FKM (FPM) VS 352-010-S82-VS 352-020-S82-VS 352-030-S82-VS –

103
Metering device
Metering devices for oil

370

Description
Technical data
Series 370 relubrication metering devices were developed for use
Function principle metering device
with single-line, centralized lubrication systems for oil Designed Outlets 2, 3 or 5
for installation directly on the machine/system requiring lubrication, Metering quantity 0,05 to 1,50 cm 3
these metering devices are available in two-, three- and five-port 0.003 to 0.091 in 3
Lubricant mineral and synthetic oil
models Series 370 metering devices can be ordered with fittings for 20 to 2 000 mm 2/s
the main line connection by selecting the appropriate order code 0.031 to 3.100 in 2/s
Operating temperature –20 to +80 °C; –4 to +176 °F
Operating pressure min 20 bar; 290 psi
Features and benefits max 80 bar; 1 160 psi
Relief pressure ≤1 bar, 14.5 psi
Materials zinc die-cast, brass, copper, steel, NBR
• For use with distributor bodies having two, three and
Connection main line different fittings for pipe ø 6 to 12 mm;
five ports to match number of lubrication points 0.236 to 0.472 in or closure plugs for
thread M 12×1
• Designed for installation directly on the machine/ Connection outlet pipe ø 4 mm; 0 16 in - metering nipple
system requiring lubrication (VS) with SKF Quick Connector -
metering nipple (00) for solderless
• Choose optional metering nipples and push-in or screw-in pipe connection (DIN 3862)
type fittings for feed line connections Dimensions min 37 × 75 × 50,5 mm
max 88 × 75 × 56,5 mm
• Select SKF Quick Connector or screw-in type main line fittings min. 1.456 × 2.952 × 1.988 in
max. 3.464 × 2.952 × 2.224 in
• Current metering nipples are easily exchangeable Mounting position any
to yield different output quantities

Applications
• Machine tools
• Printing machines
NOTE
• Packaging industry Further technical information, technical drawings,
• Textile industry accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

104
Metering device

Metering devices for oil


370
Identification code 3 7 – 2 – – 0 0

Metering point 1

Metering point 2

Metering point 3
(0 = not present, on VN2)
Metering point 4
(0 = not present, on VN2)
Metering point 5
(0 = not present, on VN2)
Product series

Number of metering points


2 = 2 outlets
3 = 3 outlets
5 = 5 outlets
Lubrication line fitting
00 = Solderless pipe connection
VS = SKF Quick Connector
Metering quantity
3 = 0,05 cm 3, 0.0030 in 3 7 = 0,60 cm 3, 0.0366 in 3
4 = 0,10 cm 3, 0.0061 in 3 8 = 1,00 cm 3, 0.0610 in 3
5 = 0,20 cm 3, 0.0122 in 3 9 = 1,50 cm 3, 0.0915 in 3
6 = 0,40 cm 3, 0.0244 in 3
Fittings for main line connection
B = Solderless pipe connection ø 6 mm, 0 23 in P = Straight adapter with EO-2 functional nut ø 10 mm, 0 39 in
C = Solderless pipe connection ø 8 mm, 0 31 in R = Straight adapter with EO-2 functional nut ø 12 mm, 0 47 in
D = Solderless pipe connection ø 10 mm, 0 39 in S = Straight adapter with SKF Quick Connector ø 6 mm, 0 23 in
E = Banjo fitting DIN 3862 with flat washer, lockable ø 6 mm, 0 23 in T = Straight adapter with SKF Quick Connector ø 8 mm, 0 31 in
F = Banjo fitting DIN 3862 with flat washer, lockable ø 8 mm, 0 31 in W = Banjo fitting with SKF Quick Connector ø 6 mm, 0 23 in
H = Screw plug with flat washer X = Banjo fitting with SKF Quick Connector ø 8 mm, 0 31 in
M = Straight adapter with EO-2 functional nut ø 6 mm, 0 23 in Z = Without fitting, solderless pipe connection
N = Straight adapter with EO-2 functional nut ø 8 mm, 0 31 in

Accessory

Exchangeable metering nipples


Solderless pipe SKF Quick
connection Connector

Order numbers for metering nipples* (replaceable)


Outlet ø Elastomer Metering quantity

0,05 cm 3 0,10 cm 3 0,20 cm 3 0,40 cm 3 0,60 cm 3 1,00 cm 3 1,50 cm 3


mm in 0.003 in 3 0.006 in 3 0.012 in 3 0.024 in 3 0.036 in 3 0.061 in 3 0.092 in 3
4 0.157 NBR V72-005 V71-010 V71-020 V71-040 V71-060 V71-100 V71-150

* Metering nipples are made of brass

105
Metering device
Metering devices for oil

391

Description
Technical data
Series 391 single-port prelubrication metering devices were devel-
Function principle metering device
oped for use with single-line, centralized lubrication systems for oil Outlets 1
and fluid grease Designed for installation in manifolds, these meter- Metering quantity oil: 0,2 to 1,5 cm 3; 0.01 to 0.09 in 3
ing devices provide flexible system design when combined with one- fluid grease: 0,1 to 0,3 cm 3
0.006 to 0.02 in 3
to six-port manifolds Customized manifolds for series 391 are avail- Lubricant mineral and synthetic oil,
able in aluminum 20 to 2 000 mm 2/s,
fluid grease NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to +176 °F
Features and benefits Operating pressure min 8 bar, 116 psi
max 45 bar, 653 psi
Relief pressure max 7 bar; 1 01.5 psi
• For use with manifolds having one to six ports
Materials aluminum, brass (oil), nickel-plated
to match number of lubrication points brass (fluid grease), copper,
FKM (FPM)/NBR
• Provides flexible options for systems with remote single Connection main line pipe ø 6 to 12 mm
lubrication points or multiple-port metering devices 0.236 to 0.472 in
with up to six ports solderless pipe connection
for threads G 1/8; G 1/4; M 10×1
• Select screw-in type metering nipples with or M 14×1,5 (DIN 3862)
Connection outlet pipe ø 4 mm; 0.16 in - metering nipple
feed line connections via order code (00) for solderless pipe connection
• Choose separately manifold models with different Dimensions min 67,5 × 22 mm
max 78,5 × 22 mm
thread sizes for main line connection min. 2.657 × 0.866 in
max. 3.091 × 0.866 in
• Current metering nipples are exchangeable to yield Mounting position any
different output quantities

Applications
• Machine tools NOTE
Further technical information, technical drawings,
• Printing machines
accessories, spare parts or product function descriptions
• Packaging industry available on SKF com/lubrication:
• Textile industry 1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

106
Metering device

Metering devices for oil


391
Identification code 3 9 1 – 0 0 – 0 0 0 0 – 0 0

Product series

Number of metering points (1)

Design and metering quantity

Design code 0 8 1
Lubricant Oil Oil Fluid grease
ø Outlet [mm] 4 4 4
Distributor body Aluminum Aluminum Aluminum
Metering nipple Brass Brass Brass, nickel-plated
Elastomer NBR FKM (FPM) NBR
Threaded seal Flat washer* Flat washer* Flat washer*
Connection outlet 00 00 00

0,10 cm 3 – – 4
0,20 cm 3 5 5 5
0,30 cm 3 – – 6
quantity code

0,40 cm 3 6 6 –
Metering

0,60 cm 3 7 7 –
1,00 cm 3 8 8 –
1,50 cm 3 9 9 –

* Flat washer must be ordered separately Order number: DIN7603-A14x18-CU

Accessory

Manifold
Manifold VL
Identification code V L – C A

Product series

Number of ports
01 = 1 screw-in point 04 = 4 screw-in points
02 = 2 screw-in points 05 = 5 screw-in points
03 = 3 screw-in points 05 = 6 screw-in points
(other numbers of ports available on request)
Description
Design of metering device pipe thread
For 391 metering devices, VL-manifolds are C = Normal profile, M 14×1,5 with counterbore for flat washer
utilized for one to six screw-in points with
Material
thread M 14×1,5 mm for flat (copper) washer
sealing Various main line connections can A = Aluminum
be selected via order code Design of main line connection
G1 = G 1/8 per DIN 3852-2, Form X, small M4 = M14x1,5 with counterbore for solder-
G2 = G 1/4 per DIN 3852-2, Form X, small less pipe connection per DIN 3862 (can only
M3 = M10x1 with counterbore for solderless pipe be selected for normal profile)
connection per DIN 3862

107
Metering device
Metering devices for oil

390

Description
Technical data
Series 390 prelubrication metering devices were developed for
Function principle metering device
use with single-line, centralized lubrication systems for oil and fluid Outlets 2 or 3
grease Designed for installation directly on the machine/system Metering quantity oil: 0,2 to 1,5 cm 3
requiring lubrication, these metering devices can be ordered with 0.01 to 0.915 in 3
fluid grease: 0,1 to 0,3 cm 3
fittings for the main line connection by selecting the appropriate 0.006 to 0.0183 in 3
order code
Lubricant mineral and synthetic oil
20 to 2 000 mm 2/s
Features and benefits 0.031 to 3.100 in 2/s
fluid grease of NLGI 000, 00
Operating temperature 0 to +80 °C; +32 to +176 °F
• For use with distributor bodies having two or three ports
Operating pressure min 8 bar, 116 psi
to match number of lubrication points max 45 bar, 653 psi
Relief pressure max 7 bar, 1 01.5 psi
• Designed for installation directly on the machine/ Materials zinc die-cast, brass (oil), nickel-plated
system requiring lubrication brass (fluid grease), copper, steel,
FKM (FPM)/NBR
• Select screw-in type metering nipples Connection main line different fittings for pipe
for feed line connections ø 6 to 12 mm; 0.236 to 0.472 in
or closure plugs for thread M 12×1
• Choose push-in or screw-in type main line fittings Connection outlet pipe ø 4 mm; 0.16 in - metering nipple
(00) for solderless pipe connection
• Current metering nipples are exchangeable (DIN 3862)
to yield different output quantities Dimensions min 50 × 89 × 23 mm
max 71 × 89 × 23 mm
min. 1.968 × 3.503 × 0.905 in
max. 5.393 × 3.503 × 0.905 in
Applications Mounting position any
• Machine tools
• Printing machines
NOTE
• Packaging industry Further technical information, technical drawings,
• Textile industry accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

108
Metering device

Metering devices for oil


390
Identification code 3 9 – 0 0 – 0 0 –

Product series

Number of metering points (2, 3)

Design and metering quantity Fittings for main line connection


Main line
Design code 0 8 1 Designation [mm] Code
Lubricant Oil Oil Fluid grease
6 B
Straight adapter
ø Outlet [mm] 4 4 4 8 C
DIN 3862 with flat washer
10 D
Distributor body Zinc die-cast Zinc die-cast Zinc die-cast Banjo fitting DIN 3862 6 E
Metering nipple Brass Brass Brass (n.p.) with flat washer, lockable 1) 8 F
Screw plug with flat washer – H
Elastomer NBR FKM (FPM) NBR
6 M
Connection outlet 00 00 00 Straight adapter 8 N
with EO-2 functional nut 10 P
0,10 cm 3 – – 4 12 R
0,20 cm 3 5 5 5 Straight adapter 6 S
0,30 cm 3 – – 6
quantity code

with SKF Quick Connector 8 T


0,40 cm 3 6 6 – 6 W
Banjo fitting with
Metering

0,60 cm 3 7 7 – SKF Quick Connectors, not lockable 8 X


1,00 cm 3 8 8 –
1,50 cm 3 9 9 – Without fitting (M12x1 thread) – Z
closed * V V V
* V = Metering quatity of 0,20 cm 3, closed 1) Banjo bolt only inserted in delivery condition, not tightened

Accessory

Exchangeable metering nipples


Order numbers for metering nipples for oil (replaceable)
Outlet ø Material Metering Metering quantity
elastomer nipple
0,2 cm 3 0,4 cm 3 0,6 cm 3 1,0 cm 3 1,5 cm 3
mm in 0.012 in 3 0.024 in 3 0.036 in 3 0.061 in 3 0.092 in 3

4 0.16 NBR brass 391-020-K 391-040-K 391-060-K 391-100-K 391-150-K


4 0.16 FKM (FPM) brass 391-020-K-S8 391-040-K-S8 391-060-K-S8 391-100-K-S8 391-150-K-S8

Order numbers for metering nipples for fluid grease (replaceable)


Outlet ø Material Metering nipple Metering quantity
elastomer
0,10 cm 3 0,20 cm 3 0,30 cm 3
mm in 0.006 in 3 0.012 in 3 0.018 in 3

4 0.16 NBR brass, nickel-plated 391-010-K-S1 391-020-K-S1 391-030-K-S1

109
Metering device
Metering devices for oil

321 G, T, W, G4, Module, G7

G G4

T Module

W G7

Description
Technical data
Series 321 single-port prelubrication metering devices were devel-
oped for use with single-line, centralized lubrication systems for oil Function principle metering device
and fluid grease These metering devices are designed for installation Outlets 1
Metering quantity Model G, G4, T, W, Modular:
directly in a lubrication point, which eliminates feeding lubricant via a 0,01 to 0,10 cm 3; 0.0006 to 0.006 in 3
lubrication point line, as well as the lubrication line at the lubrication Model G7: 0,01 to 0,3 cm 3
0.0006 to 0.018 in 3
point This can be beneficial where space is limited Choose from six Lubricant mineral and synthetic oil,
types to meet application requirements 20 to 2 000 mm 2/s, 0 031 to 3 100 in 2/s
fluid grease of NLGI 000, 00,0
Operating temperature 0 to +80 °C; +32 to +176 °F
Features and benefits Operating pressure min 12 bar, 174 psi
max 45 bar, 653 psi
• Specially designed, single-port metering device for prelubrication
Relief pressure max 3 bar, max. 43.5 psi
• For direct connection to the main line Materials steel (galvanized, Cr6-free) or brass,
• No separate lubrication line and fittings are necessary NBR , G7 FKM (FPM)
Connection main line different fittings for pipe ø 6 to 10 mm;
• Screw-in type can be monitored by a pressure switch 0.236 to 0.393 in or closure plugs for
in the main line; suitable for feed line ø 4 mm (oil) thread M 10×1
and ø 6 mm (fluid grease) Connection outlet pipe ø 4 and ø 6 mm; 0.157 to 0.236 in
- straight compression nut fitting
- solderless pipe union (DIN 3862)
Applications Dimensions: 321 G length: 50 mm; 1.968 in
ø: 16,2 mm; 0.638 in
• Machine tools wrench size 14 mm
• Printing machines Dimensions: 321 W length: 46 mm; 1.811 in
width: 26 mm; 1.023 in
• Packaging industry ø: 11,5 mm; 0.453 in
• Textile industry wrench size 10 mm
Dimensions: 321 G4 length: 40,5 mm; 1.594 in
ø: 19,6 mm; 0.771 in
wrench size 17 mm
Dimensions: 321 T length: 43 mm; 1.692 in
NOTE width: 61 mm; 2.401 in
ø: 16,2 mm; 0.638 in
Further technical information, technical drawings, wrench size 14 mm
accessories, spare parts or product function descriptions Dimensions: 321 Module ø: 30 mm; 1.181 in
available on SKF com/lubrication: height or thickness: 11 mm; 0.433 in
Dimensions: 321 G7 small length: 30 mm; 1.181 in
1-5001-EN ø: 10,3 mm; 0.405 in
3D Dimensions: 321 G7 large length: 50 mm; 1.968 in
ø: 13,5 mm; 0.531 in
skf-lubrication partcommunity com/3d-cad-models Mounting position any

110
Metering device

Metering devices for oil


321 G, T, W, G4, Module, G7
Order information
Order number Outlet ø Lubricant Metering quantity Pipe thread of
lubrication point line
321 G 321 T 321 W Oil Fluid grease

mm in cm 3 in 3

321-401G1 – – 4 0.157 • – 0,01 0.0006 M8×1 taper


321-401G2 321-401T2 321-401W2 4 0.157 • – 0,01 0.0006 M 10×1 taper
321-401G3 – – 4 0.157 • – 0,01 0.0006 R 1/8 taper

321-403G1 321-403T1 321-403W1 4 0.157 • – 0,03 0.0018 M8×1 taper


321-403G2 321-403T2 321-403W2 4 0.157 • – 0,03 0.0018 M 10×1 taper
321-403G3 321-403T3 321-403W3 4 0.157 • – 0,03 0.0018 R 1/8 taper

321-406G1 321-406T1 321-406W1 4 0.157 • – 0,06 0.0036 M8×1 taper


321-406G2 321-406T2 321-406W2 4 0.157 • – 0,06 0.0036 M 10×1 taper
321-406G3 321-406T3 321-406W3 4 0.157 • – 0,06 0.0036 R 1/8 taper

321-410G1 321-410T1 321-410W1 4 0.157 • – 0,10 0.0061 M8×1 taper


321-410G2 321-410T2 321-410W2 4 0.157 • – 0,10 0.0061 M 10×1 taper
321-410G3 321-410T3 321-410W3 4 0.157 • – 0,10 0.0061 R 1/8 taper

321-601G1 – 321-601W1 6 0.236 • • 0,01 0.0006 M8×1 taper


321-601G2 321-601T2 321-601W2 6 0.236 • • 0,01 0.0006 M 10×1 taper
– 321-601T3 321-601W3 6 0.236 • • 0,01 0.0006 R 1/8 taper

321-603G1 321-603T1 321-603W1 6 0.236 • • 0,03 0.0018 M8×1 taper


321-603G2 321-603T2 321-603W2 6 0.236 • • 0,03 0.0018 M 10×1 taper
321-603G3 321-603T3 321-603W3 6 0.236 • • 0,03 0.0018 R 1/8 taper

321-606G1 – 321-606W1 6 0.236 • • 0,06 0.0036 M8×1 taper


321-606G2 321-606T2 321-606W2 6 0.236 • • 0,06 0.0036 M 10×1 taper
321-606G3 321-606T3 321-606W3 6 0.236 • • 0,06 0.0036 R 1/8 taper

321-610G1 321-610T1 321-610W1 6 0.236 • • 0,10 0.0061 M8×1 taper


321-610G2 321-610T2 321-610W2 6 0.236 • • 0,10 0.0061 M 10×1 taper
321-610G3 321-610T3 321-610W3 6 0.236 • • 0,10 0.0061 R 1/8 taper

* Designs G, T, W elastomer material NBR

Order numbers 321 G4, Module, G7


Order number Outlet ø Lubricant Metering quantity

321 G4 321 Module 321 G7 small 321 G7 large Oil Fluid grease

mm in cm 3 in 3

– 321-101 321-401G7 – 4 0.157 • • 0,01 0.0006


321-403G4 321-103 321-403G7 – 4 0.157 • • 0,03 0.0018
– – 321-403G7-S8 – 4 0.157 • • 0,03 0.0018

321-406G4 321-106 321-406G7 – 4 0.157 • • 0,06 0.0036


– – 321-406G7-S8 – 4 0.157 • • 0,06 0.0036

321-410G4 – 321-410G7 321-610G7 4 0.157 • • 0,10 0.0061


– – 321-410G7-S8 – 4 0.157 • • 0,10 0.0061

– – – 321-616G7 6 0.236 • • 0,16 0.0098


– – – 321-620G7 6 0.236 • • 0,20 0.0122
– – – 321-630G7 6 0.236 • • 0,30 0.0180

111
Metering device
Metering devices for oil

AB

Description
Technical data
Designed for installation in manifolds, series AB single-port, prelu-
Function principle metering device
brication metering devices were developed for use with single-line, Outlets 1
centralized lubrication systems for oil and fluid grease When com- Metering quantity 0,01 to 0,60 cm 3, 0.0006 to 0.04 in 3
bined with one- to six-port manifolds, these metering devices pro- Lubricant mineral and synthetic oil,
20 to 2 000 mm 2/s, 0.031 to 3.100 in 2/s,
vide flexibility in lubrication system design The metering device body fluid grease of NLGI 000, 00
is available in steel and stainless steel versions with copper or stain- Operating temperature 0 to +80 °C; +32 to +176 °F
less steel sealing rings Operating pressure min 18 bar, 260 psi
max 50 bar, 725 psi
Relief pressure max 3 bar, 43.5 psi
Materials steel (galvanized, Cr6-free), stainless
Features and benefits steel, copper, steel, flat washer (copper,
stainless steel), FKM (FPM)
• For use with manifolds having one to six ports Connection main line pipe ø 6 to 10 mm; 0.236 or 0.393 in;
to match number of lubrication points solderless pipe connection for threads
G 1/8; G 1/4; M 10×1 or M 14×1,5
• Provides flexible options for systems with remote single (DIN 3862)
lubrication points or multiple-port metering devices with Connection outlet Connection outlet: pipe ø 4 mm; 0.16 in,
straight compression nut fitting
up to six ports Dimensions min 43 × 14 mm
max 82,5 × 14 mm
• Virtually maintenance-free min. 1.692 × 0.551 in
• Select screw-in type metering device for feed line max. 1.228 × 0.551 in
Mounting position any
connection via order code
• Choose separately manifold models with different
thread sizes for main line connection and materials

Applications
• Machine tools NOTE
Further technical information, technical drawings,
• Printing machines
accessories, spare parts or product function descriptions
• Packaging industry available on SKF com/lubrication:
• Textile industry 1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

112
Metering device

Metering devices for oil


AB
Identification code 2 4 – 2 8 0 0 – 0

Product series AB

Lubricant
5 = Oil/fluid grease, galvanized steel, copper ring
9 = Oil/fluid grease, stainless steel, stainless steel ring

Metering quantity
01 = 0,01 cm 3, 0.0006 in 3
02 = 0,02 cm 3, 0.0012 in 3
03 = 0,03 cm 3, 0.0018 in 3
05 = 0,05 cm 3, 0.0030 in 3
10 = 0,10 cm 3, 0.0061 in 3
20 = 0,20 cm 3, 0.0122 in 3
40 = 0,40 cm 3, 0.0244 in 3
60 = 0,60 cm 3, 0.0366 in 3

Accessory

Manifold
Manifold VL
Identification code V L –
Product series

Number of ports
01 = 1 screw-in point 04 = 4 screw-in points
02 = 2 screw-in points 05 = 5 screw-in points
03 = 3 screw-in points 05 = 6 screw-in points
(other numbers of ports available on request)
Description
Design of metering device pipe thread
For series AB metering devices, VL-mani-
B = Normal profile, M 10×1 with counterbore for flat washer or O-ring
folds are utilized for one to six screw-in
points with thread M 10x1 mm for flat Material
(copper) washer sealing Normal-profile A = Aluminum E = Stainless steel (1 4305) (can only be selected for normal profile)
manifolds are available in aluminum or Design of main line connection
stainless steel, while narrow-profile G1 = G 1/8 per DIN 3852-2, Form X, small
manifolds are offered only in aluminum G2 = G 1/4 per DIN 3852-2, Form X, small
Various main line connections can be M3 = M10x1 with counterbore for solderless pipe connection per DIN 3862
M4 = M14x1,5 with counterbore for solderless pipe connection per DIN 3862
selected via order code (can only be selected for normal profile)

113
Metering device
Metering devices for oil

VN

Description
Technical data
Developed for use with single-line, centralized lubrication systems
Function principle metering device
for fluid grease, series VN relubrication metering devices are offered Outlets 2, 4 or 6
with two, four or six ports These metering devices were designed for Metering quantity 0,05 to 1,00 cm 3
installation directly on the vehicle or construction machine requiring 0.003 to 0.061 in 3
Lubricant fluid grease of NLGI 000, 00
lubrication Series VN metering devices can be ordered with fittings Operating temperature –25 to +80 °C; –13 to +176 °F
for the main line connection via the appropriate order code Operating pressure min 20 bar; 290 psi
max 80 bar; 1 160 psi
Relief pressure ≤1 bar, ≤14.5 psi
Features and benefits Materials zinc die-cast, brass, steel, flat washer
(copper), NBR
Connection main line different fittings for pipe ø 6 to 10 mm;
• Choose metering device with two, four or six points
0.236 to 0.393 in or closure plugs for
to match number of lubrication points thread M8x1
Connection outlet pipe ø 4 mm metering nipple (VS) with
• Designed for installation directly on the vehicle/machine SKF Quick Connector - metering nipple
requiring lubrication (00) for solderless pipe connection
Dimensions min 62 × 83,5 × 52 mm
• Select metering nipples and push-in or screw-in type max 130,5 × 83,5 × 58 mm
fittings for feed line or main line connections min. 2.440 × 3.287 × 2.047 in
max. 5.118 × 3.287 × 2.283 in
• Easy metering adjustment by replacing metering nipples Mounting position any

• Black-coloured surface for optimized corrosion protection

Applications
• Commercial vehicles
• Construction machinery
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-5001-EN
3D
skf-lubrication partcommunity com/3d-cad-models

114
Metering device

Metering devices for oil


VN
Identification code V N – 0 – –

Metering point 1

Metering point 2

Metering point 3
(0 = not present, on VN2)
Metering point 4
(0 = not present, on VN2)
Metering point 5
(0 = not present, on VN2/4)
Metering point 6
(0 = not present, on VN2/4)
Product series

Number of metering points


2 = 2 outlets
4 = 4 outlets
6 = 6 outlets
Lubrication line fitting
00 = Solderless pipe connection
VS = SKF Quick Connector
Metering quantity
1 = 0,05 cm 3, 0.003 in 3 5 = 0,40 cm 3, 0.024 in 3
2 = 0,10 cm 3, 0.006 in 3 6 = 0,60 cm 3, 0.036 in 3
3 = 0,20 cm 3, 0.012 in 3 7 = 1,00 cm 3, 0.061 in 3
4 = 0,30 cm 3, 0.018 in 3
Fittings for main line connection
A = Solderless pipe connection ø 8 mm, 0 315 in
E = Solderless pipe connection ø 6 mm, 0 236 in
H = Screw plug with flat washer
S = SKF Quick Connector ø 10 mm, 0 01 in
Z = Without fitting

Accessory

Exchangeable metering nipples


Solderless pipe SKF Quick
connection Connector

Order numbers for metering nipples* (replaceable)


Outlet ø Elastomer Metering quantity

0,05 cm 3 0,10 cm 3 0,20 cm 3 0,30 cm 3 0,40 cm 3 0,60 cm 3 1,00 cm 3


mm in 0.003 in 3 0.006 in 3 0.012 in 3 0.018 in 3 0.024 in 3 0.036 in 3 0.061 in 3
4 0.16 NBR VKU005-K VKU010-K VKU020-K VKU030-K VKU040-K VKU060-K VKU100-K

* Metering nipples are made of brass

115
Metering device
Metering devices for oil

OI-AL-SR

Description
Technical data
Developed for use in single-line, centralized lubrication systems,
Function principle metering device
series OI-AL-SR single-port, prelubrication metering devices Outlets 1
(cartridges) feature an integrated control pin and are designed for Metering quantity 0,02; 0,05; 0,10 cm 3;
installation in manifolds or in base plates with up to 40 lubrication 0.001; 0.003; 0.006 in 3
Lubricant mineral and synthetic oil,
points Three cartridge models with different fixed metering quanti- 22 to 1 000 mm 2/s, 0.034 to 1.55 in 2/s,
ties provide flexible lubrication system design Reduced feeding of fluid grease of NLGI 000, 00
main lines and feed lines in machines/systems saves on materials Operating temperature +5 to 120 °C; +41 to 248 °F
Operating pressure min 30 bar; 435 psi
and installation costs max 100 bar; 1 450 psi
Relief pressure max 5 bar; 72.5 psi
Material cartridge aluminum
Features and benefits Material manifold AlCuMgPb F37 DIN 1796
Material base plate AlMgSi1 F28-32 or AlCuMg1 F28
• Screw-in type, single-port metering device with FKM (FPM)
Connection main line SKF Quick Connector or solderless pipe
cartridges for prelubrication connection for thread G 1/8 (F)
• For use with manifolds having one to eight ports or with base Connection outlet SKF Quick Connector or solderless pipe
connection for thread G 1/8 (F)
plates with up to 40 ports to match number of lubrication points Dimensions min 120 × 35 × 105 mm
max 300 × 35 × 105 mm
• Suitable for many lubrication points in constricted rooms min. 4.72 × 1.38 × 4.13 in
• All main line and feed line connections are located max. 11.81 × 1.38 × 4.13 in
Mounting position any
internally in the manifolds or base plates
• Simplifies installation, control function and replacement
by use of one unit

Applications
• Glass industry NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
951-231-001
3D
skf-lubrication partcommunity com/3d-cad-models

116
Metering device

Metering devices for oil


OI-AL-SR
Order information

Order Number Metering quantity


number of outlets Outlet 1 Outlet 2 Outlet 3 Outlet 4 Outlet 5 Outlet 6 Outlet 7 Outlet 8
cm 3 in 3 cm 3 in 3 cm 3 in 3 cm 3 in 3 cm 3 in 3 cm 3 in 3 cm 3 in 3 cm 3 in 3

647-41151-2 2 0,02 0.001 0,02 0.001 – – – – – – – – – – – –


647-41152-2 3 0,02 0.001 0,02 0.001 0,02 0.001 – – – – – – – – – –
647-41152-4 3 0,10 0.006 0,05 0.003 0,05 0.003 – – – – – – – – – –
647-41153-2 4 0,05 0.003 0,05 0.003 0,05 0.003 – – – – – – – – – –
647-41154-4 5 0,02 0.001 0,02 0.001 0,02 0.001 0,02 0.001 0,02 0.001 – – – – – –
647-41154-5 5 0,02 0.001 0,02 0.001 0,02 0.001 0,02 0.001 – – – – – – – –
647-41154-7 5 0,02 0.001 0,05 0.003 0,05 0.003 0,05 0.003 0,05 0.003 – – – – – –
647-41154-6 5 0,05 0.003 0,05 0.003 0,05 0.003 0,05 0.003 – – – – – – – –
647-41155-2 6 0,10 0.006 0,05 0.003 0,05 0.003 0,05 0.003 0,05 0.003 0,05 0.003 – – – –
647-41156-2 8 0,05 0.003 0,05 0.003 0,05 0.003 0,05 0.003 0,02 0.001 0,02 0.001 0,02 0.001 – –

Accessories

Cartridges, manifolds and base plates


Cartridge Manifold Base plate

Cartridges Manifolds Baseplates

Order number Metering quantity Order number Number of ports Order number Number of ports

547-33924-1 0,02 cm 3/stroke 447-71901-1 2 447-71899-1 40


547-33925-1 0,05 cm 3/stroke 447-71902-1 3
547-33926-1 0,10 cm 3/stroke 447-71903-1 4
447-71904-1 5
447-71905-1 6
447-71906-1 8

117
Metering device
Metering devices for oil

SL-42

Description
Technical data
Series SL-42 metering devices were developed for single-line,
centralized lubrication systems dispensing oil or fluid grease Lubri- Function principle metering device
Outlets 1
cant output is externally adjustable, and the indicator stem permits a Metering quantity adjustable from 0,016 to 0,049 cm 3,
visual check of metering device operation These carbon steel meter- 0.001 to 0.003 in 3
ing devices are available with nitrile or fluoroelastomer packings Lubricant mineral and synthetic oil and fluid
grease
Metering devices with fluoroelastomer packings (indicated by black Operating temperature standard: -26 to +93 °C; -15 to +200 °F
adjustment caps) are used for applications requiring heat resistance heat resistant: max +176 °C; +350 °F
or when a lubricant requires it for compatibility Operating pressure min 52 bar, 750 psi
max 70 bar, 1 000 psi
Relief pressure < 10 bar, 150 psi
Materials carbon steel, stainless steel, brass,
Features and benefits steel, Nitrile (NBR) or fluoroelastomer
• Screw-in type, single-port metering device for (FKM, FPM) packings
(indicated by black adjustment caps)
prelubrication affixed by adapter bolts (heat resistance application)
• Suitable for use with manifolds having one to Connection main line 1/8 NPTF (F)
Connection outlet pipe 1/8 O D connections 1)
15 ports to match number of lubrication points Dimensions min 41 × 62 × 43 mm
• Output is externally adjustable max 308 × 62 × 43 mm
min. 1.6 × 2.4 × 1.7 in
• Indicator stem permits visual check of max. 12.1 × 2.4 × 1.7 in
metering device operation Mounting position any
• May be combined in a circuit with SL-41, SL-43
and/or SL-44 metering devices
• Individual metering devices can be removed easily 1) Different adapters are possible † see accessories
for inspection or replacement Note: When using feed line tubing of 1/8 O D the feed line must not exceed a length of 7,5 m;
295 in based on oil +18 °C; +65 °F

Applications
• Paper converting NOTE
Further technical information, technical drawings,
• Plastic processing
accessories, spare parts or product function descriptions
• Printing
available on SKF com/lubrication
• Packaging
• Metalworking
• Material handling equipment

118
Metering device

Metering devices for oil


SL-42
Identification code –

Product series
83311 = SL-42 standard with nitrile packings
84428 = SL-42 heat resistant with fluoroelastomer packings
85352 = SL-42 standard with nitrile packings for metric tube connection
O D 4 and 6 mm, up to 6 outlets
Number of metering devices
1 = 1 metering device, mounted in a manifold
2 = 2 metering devices, mounted in a manifold
3 = 3 metering devices, mounted in a manifold
4 = 4 metering devices, mounted in a manifold
5 = 5 metering devices, mounted in a manifold
6 = 6 metering devices, mounted in a manifold
10 = 10 metering devices, mounted in a manifold
15 = 15 metering devices, mounted in a manifold

Accessories

Metering devices, manifolds and adapters


Metering device Manifold Adapter

This picture shows a manifold example Please note,


the real manifold differs in terms of size and design

Replacement for manifold injectors Manifolds G 1/8 to metric fitting adapters

Order number Designation Order number 1) Number of ports Order Pipe Material
number ø mm
83535 standard single metering 91863-1 1 249281 4 steel
device/no manifold, 91864-1 2 249279 4 stainless steel
1 outlet, 1/8 NPTF (M) inlet 91865-1 3
91866-1 4 249282 6 steel
83313 metering device for 14361 5 249280 6 stainless steel
standard manifold 91976-1 6
14312 10
84048 metering device for 14253 15
heat-resistant manifold
1) Injectors, except replacement injectors for manifold,
249649 metric replacement include compression nut and ferrule for tubing 1/8 in O D
injector as standard Injectors with manifolds include two
mounting clips and screws

119
Metering device
Metering devices for oil

SL-43

Description
Technical data
Series SL-43 metering devices were developed for single-line,
centralized lubrication systems dispensing oil or fluid grease Lubri- Function principle metering device
cant output is externally adjustable, and the indicator stem permits a Outlets 1
Metering quantity adjustable from 0,016 to 0,131 cm 3
visual check of metering device operation These carbon steel meter- 0.001 to 0.008 in 3
ing devices are available with nitrile or fluoroelastomer packings Lubricant mineral and synthetic oil
Operating temperature standard:
Metering devices with fluoroelastomer packings (indicated by black -26 to +93 °C; -15 to +200 °F
adjustment caps) are used for applications requiring heat resistance heat resistant:
or when a lubricant requires it for compatibility max +176 °C; +350 °F
Operating pressure min 52 bar, 750 psi
max 70 bar; 1 000 psi
Features and benefits Relief pressure < 10 bar, 150 psi
Materials carbon steel, stainless steel, brass, steel,
• Screw-in type, single-port metering device for Nitrile (NBR) or fluoroelastomer (FKM,
prelubrication affixed by adapter bolts FPM) packings (indicated by black
adjustment caps) (heat resistance
• Suitable for use with manifolds having one to four ports to match application)
number of lubrication points Connection main line 1/4 NPTF (F)

• Output is externally adjustable Connection outlet pipe 1/8 O D connections 1)


Dimensions min 44 × 79 × 52 mm
• Indicator stem permits visual check of metering device operation max 102 × 79 × 52 mm
• May be combined in a circuit with SL-41, SL-42 and/or SL-44 min. 1.7 × 3.1 × 2.0 in
metering devices max. 4.0 × 3.1 × 2.0 in
Mounting position any
• Individual metering devices can be removed easily
for inspection or replacement
1) Different adapters are possible † see accessories
Applications Note: When using feed line tubing of 1/8 O D the feed line must not exceed a length of 7,5 m;
295 in based on oil +18 °C; +65 °F
• Glass processing
• Paper converting
• Plastic processing NOTE
• Printing and packaging Further technical information, technical drawings,
• Metalworking accessories, spare parts or product function descriptions
• Material handling equipment available on SKF com/lubrication

120
Metering device

Metering devices for oil


SL-43
Identification code –

Product series
83661 = SL-43 standard with nitrile packings
84429 = SL-43 heat resistant with fluoroelastomer packings
Number of metering devices
1 = 1 metering device, mounted in a manifold
2 = 2 metering devices, mounted in a manifold
3 = 3 metering devices, mounted in a manifold
4 = 4 metering devices, mounted in a manifold

Accessories

Metering devices, manifolds and adapters


Metering device Manifold Adapter

This picture shows a manifold example Please note,


the real manifold differs in terms of size and design

Replacement for manifold injectors Manifolds G 1/8 to metric fitting adapters

Order number Designation Order number 1) Number of ports Order Pipe Material
number ø mm
83662 standard single metering 91883-1 1
device/no manifold, 91884-1 2 249281 4 steel
1 outlet, 1/8 NPTF (M) inlet 91885-1 3 249279 4 stainless steel
91886-1 4
83660 metering device for 249282 6 steel
standard manifold 249280 6 stainless steel

84110 metering device for


heat-resistant manifold
1) Injectors, except replacement injectors for manifold,
include compression nut and ferrule for tubing 1/8 in O D
as standard Injectors with manifolds include two
mounting clips and screws

121
Metering device
Metering devices for oil

SL-41

Description
Technical data
Series SL-41 metering devices are designed for use in high-temper-
ature applications, depending on the lubricant These metering Function principle metering device
devices are available installed only in manifolds with 3/8-inch NPT Outlets 1 to 5
Metering quantity adjustable from 0,13 to 1,31 cm 3
female inlets and feature a tamper-resistant adjustment screw that 0.008 to 0.0689 in 3
does not incorporate a visual indicator Lubricant mineral and synthetic oil
Operating temperature standard: -26 to +93 °C; -15 to +200 °F
heat resistant: max +176 °C; +350 °F
Operating pressure min 52 bar, 750 psi
Features and benefits max 70 bar; 1 000 psi
Relief pressure < 10 bar, 150 psi
• Screw-in type, single-port metering device Materials carbon steel, FKM (FPM)
affixed by adapter bolts Connection main line 3/8 NPTF (F)

• Suitable for use with manifolds having one to Connection outlet 1/8 NPTF (F) 1)
Dimensions min 63 × 163,5 × 52,4 mm
five ports to match number of lubrication points max 171 × 163,5 × 52,4 mm
• Output is externally adjustable min. 2.5 × 6.4 × 2.1 in
max. 6.75 × 6.4 × 2.1 in
• Individual injectors can be removed easily for
Mounting position any
inspection or replacement
• Carbon steel with fluoroelastomer packings

Applications
• Glass processing
• Metalworking
1) When using feed line tubing of 1/8 O D , feed line must not exceed a length of 7,5 m; 295 in
based on oil +18 °C; +64 °F 1/8 NPTF (F)

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

122
Metering device

Metering devices for oil


SL-41
Identification code 8 2 2 9 4 –

Product series
82294 = SL-41 heat resistant with fluoroelastomer packings

Number of metering devices


1 = 1 metering device, mounted in a manifold
2 = 2 metering devices, mounted in a manifold
3 = 3 metering devices, mounted in a manifold
4 = 4 metering devices, mounted in a manifold
5 = 5 metering devices, mounted in a manifold

Accessories

Metering devices and manifolds


Metering device Manifold

This picture shows a manifold example Please note,


the real manifold differs in terms of size and design

Replacement for manifold injectors Manifolds

Order number Designation Order number 1) Number of ports

82295 metering device for 12658 1


manifold NPTF (F) 11962 2
11963 3
82292 single metering device 11964 4
11965 5

1) Each injector has two outlets One is closed by a


closure plug, but can be used to increase outlet
quantity combined with another injector

123
Metering device
Metering devices for oil

SL-44

Description
Technical data
Series SL-44 metering devices were developed for single-line, cen-
tralized lubrication systems dispensing fluid or semi-fluid lubricants Function principle metering device
Lubricant output is externally adjustable, and the indicator stem per- Outlets 1
Metering quantity adjustable from 0,13 to 1,31 cm 3,
mits a visual check of metering device operation These carbon steel 0.008 to 0.080 in 3
metering devices feature fluoroelastomer packings Metering devices Lubricant mineral and synthetic oil
Operating temperature -26 to +93 °C; -15 to +200 °F
with fluoroelastomer packings (indicated by black adjustment caps) Operating pressure min 52 bar, 750 psi
are used for applications requiring heat resistance or when a lubri- max 70 bar, 1 000 psi
cant requires it for compatibility Relief pressure < 10 bar, 150 psi
Materials carbon steel, FKM (FPM)
Connection main line 3/8 NPTF (F)

Features and benefits Connection outlet 1) 1/8 NPTF (F)


Dimensions min 63 × 179,4 × 52,4 mm
• Screw-in type, single-port metering device for max 171 × 179,4 × 52,4 mm
prelubrication affixed by adapter bolts min. 2.5 × 7.1 × 2.1 in
max. 6.75 × 7.1 × 2.1 in
• Suitable for use with manifolds having one to five ports to match Mounting position any
number of lubrication points
• Output is externally adjustable
• Indicator stem permits visual check of operation
• May be combined in a circuit with SL-41, SL-42
and/or SL-43 metering devices
• Individual metering devices can be removed easily
for inspection or replacement

Applications 1) When using feed line tubing of 1/8 O D the feed line must not exceed a length of 7,5 m; 295 in
based on oil +18 °C; +65 °F
• Glass processing
• Paper converting
• Plastic processing NOTE
• Printing Further technical information, technical drawings,
• Packaging accessories, spare parts or product function descriptions
• Metalworking available on SKF com/lubrication
• Material handling equipment

124
Metering device

Metering devices for oil


SL-44
Identification code 8 3 7 4 9 –

Product series
83749 = SL-44 heat resistant with fluoroelastomer packings

Number of metering devices


1 = 1 metering device, mounted in a manifold
2 = 2 metering devices, mounted in a manifold
3 = 3 metering devices, mounted in a manifold
4 = 4 metering devices, mounted in a manifold
5 = 5 metering devices, mounted in a manifold

Accessories

Metering devices and manifolds


Metering device Manifold

This picture shows a manifold example Please note,


the real manifold differs in terms of size and design

Replacement for manifold injectors Manifolds

Order number Designation Order number 1) Number of ports

83748 metering device for 12658 1


manifold NPTF (F) 11962 2
11963 3
11964 4
11965 5

1) Each injector has two outlets One is closed by a


closure plug, but can be used to increase outlet
quantity combined with another injector

125
Metering devices for grease

126
Overview of grease metering devices

Metering devices for grease


Single-line metering devices

Product Cate- Lubricant Metering quantity Operating pressure Relief pressure Adjustable Function type Page
gory 1) grease max max metering
NLGI quantity

0 1 2 cm3/stroke in3/stroke bar psi bar psi

SL-33 2) 5 • • – 0,016–0,05 0.0009–0.0030 83-240 1 200-3 500 14 200 • prelubrication 128


B-doser 2) 5 • • – 0,02–0,50 0.0012–0.0305 max 150 max. 2 180 15 3) 218 3) • prelubrication 130
LG-doser 2) 5 • • – 0,02–0,50 0.0012–0.0305 max 150 max. 2 180 10 3) 145 3) • prelubrication 132

SL-32 HV 2) 6 • • • 0,016–0,13 0.0009–0.0079 83–240 1 200–3 500 28 400 • prelubrication 134


SL-1 2) 6 • • • 0,13–1,31 0.0079–0.0799 127–240 1 850–3 500 41 600 • prelubrication 135

QSL 2) 7 • • • 0,05–0,40 0.0030–0.0244 140–300 2 030–4 350 60 870 • prelubrication 136


VR 2) 7 • • • 0,10–1,30 0.0061–0.0793 100–315 1 450–4 570 30 3) 435 3) • prelubrication 138
70 3) 1 000 3) • prelubrication

SLC 7 • • • 0,10–1,40 0.0061–0.0840 150–315 2 175–4 570 68 990 • prelubrication 140

SL-11 7 • • • 0,82–8,20 0.0500–0.5002 70–240 1 000–3 500 55 800 • prelubrication 142


SL-V 7 • • • 0,25–1,31 0.0152–0.0799 128–413 1 850–6 000 70 1 000 • prelubrication 143
SL-V XL 7 • • • 0,25–5,00 0.0152–0.3050 128–413 1 850–6 000 70 1 000 • prelubrication 144

1) The category allows a simple assignment of the metering device to a pump of the same category The category results from the relief pressure,
the operating principle and the lubricant suitable for the metering device
2) Stainless steel or C5M available
3) Depending on design

127
Metering device
Metering devices for grease

SL-33

Description
Technical data
The series SL-33 metering devices are for single-line, high-pressure
Function principle metering device
centralized lubrication systems dispensing petroleum-based lubri- Outlets 1 to 4
cants with a viscosity up to NLGI 2 Output is externally adjustable Its Metering quantity 0,016 to 0,049 cm 3
indicator stem permits visual check of metering device operation 0.001 to 0.003 in 3
Lubricant grease NLGI 0, 1
May be combined in a circuit of metering devices SL-32, SL-V, SL-V Operating temperature max +93 °C; +200 °F
XL, SL-1 and/or SL-11 Individual metering devices can be removed Operating pressure 83 to 240 bar, 1 200 to 3 500 psi
easily for inspection or replacement Available in stainless steel SAE typical: 100 bar, 1 500 psi
Relief pressure 14 bar, 200 psi
304 for applications where environmental conditions are hazardous Materials carbon steel, stainless steel 304
to carbon steel or in industries preferring stainless steel Connection main line 1/8 NPTF (F), 1/8 NPTF (M)
Connection outlet 1/8 in O D tube
Lubricant point solderless pipe connection (DIN 3862)
or plug connector
Features and benefits Dimensions min 41 × 62 × 43 mm
max 156 × 62 × 43 mm
• For use with manifolds from 1 to 7 ports to match min. 1.6 × 2.4 × 1.7 in
number of lube points max. 6.1 × 2.4 × 1.7 in
Mounting position any
• Output is externally adjustable
• Can be removed easily for inspection or replacement

Applications
Metering devices, except replacement metering devices for manifold, include compression nut
and ferrule for tubing, 3,175 mm (0.125 in) O D as standard Other outlet connectors for feed line
• Food and beverage optional; metering devices with manifolds include two mounting clips and screws; metering
devices have nitrile packings Check packing compatibility with synthetic lubricants; output with
indicator cap hand-tightened is 0,016 cm 3 (0.001 in 3) Maximum output is achieved with two
turns at 0,016 cm 3 / turn (0.001 in 3 / turn)

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

128
Metering device

Metering devices for grease


SL-33
Order information

Order number Designation Material Number of outlets Manifold inlet

83309-1 metering device including manifold carbon steel 1 1/8 NPTF (F)
83309-2 metering device including manifold carbon steel 2 1/8 NPTF (F)
83309-3 metering device including manifold carbon steel 3 1/8 NPTF (F)
83309-4 metering device including manifold carbon steel 4 1/8 NPTF (F)
83309-5 metering device including manifold carbon steel 5 1/8 NPTF (M)
83309-6 metering device including manifold carbon steel 6 1/8 NPTF (F)

83900 single metering device, no manifold needed carbon steel 1 1/8 NPTF (M)
83314 single metering device for replacement carbon steel – –

83715-1 metering device including manifold stainless steel 304 1 1/8 NPTF (F)
83715-2 metering device including manifold stainless steel 304 2 1/8 NPTF (F)
83715-3 metering device including manifold stainless steel 304 3 1/8 NPTF (F)
83715-4 metering device including manifold stainless steel 304 4 1/8 NPTF (F)

83715-6 metering device including manifold stainless steel 304 6 1/8 NPTF (F)
83715-7 metering device including manifold stainless steel 304 7 1/8 NPTF (F)
83900-9 single metering device, no manifold needed stainless steel 304 1 1/8 NPTF (M)
83314-9 single metering device for replacement stainless steel 304 – –

129
Metering device
Metering devices for grease

B-doser

Description
Technical data
B-dosers are used in single-line, heavy vehicle and industrial
Function principle metering device
lubrication applications The doser group consists of a mounting rail Outlets 1 to 6
with one or more dosers attached to it Dosing modules and mount- Metering quantity 0,02 to 0,50 cm 3
ing rails are made of zinc-coated and yellow-passivated steel The 0.0012 to 0.0305 in 3
Lubricant oil and grease NLGI 000 to 1
dosage ranges of B-dosers are from 20 to 500 mm 3 Operating temperature –25 to +80 °C; –13 to +176 °F
Operating pressure max 150 bar, 2 180 psi
Relief pressure B1, B2=15 bar; 218 psi
Features and benefits B3, B4=10 bar; 145 psi
B5, B6=5 bar; 72 psi
• The output quantity of the used dosers is visible Materials zinc-coated and
yellow-passivated steel
on amount of notches at the housing
Connection main line (manifold) R 1/4 for ø 8 mm or pipe ø 1/2 in
• Suitable with optionally manifold sizes for 2-, 3- and Connection outlet 1/8 NPT(F) for ø 4 and 6 mm feedlines
Lubricant point solderless pipe connection
6-ports to match amout of lube points (1-6) (DIN 3862)
Dimensions min 15 × 90 × 15 mm
• Material of manifold : stainless steel AISI 303 max 17 × 110 × 17 mm
• Suits for ø 4 and 6 mm of feedlines min. 0.6 × 3.5 × 0.6 in
max. 0.7 × 4.3 × 0.7 in
Mounting position any
Applications
• Heavy vehicles
• Heavy industrial application

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
11276 EN
3D
skf-lubrication partcommunity com/3d-cad-models

130
Metering device

Metering devices for grease


B-doser
Identification code B – G 1 / 8 – Z N –

Product series

Metering quantity
1 = 0,02 cm 3, 0.0012 in 3
2 = 0,05 cm 3, 0.0030 in 3
3 = 0,10 cm 3, 0.0061 in 3
4 = 0,15 cm 3, 0.0091 in 3
5 = 0,20 cm 3, 0.0122 in 3
6 = adjustable 0,2 to 0,5 cm 3; 0.012 to 0.03 in 3
Mounting rail fitting
G1/8 = G1/8 fitting
Material
ZN = zinc-coated steel

Lubricant outlet
4 = connector for ø 4 mm pipe
6 = connector for ø 6 mm pipe
U = female thread NPT 1/8

Accessory

Manifold
Identification code B P L D – – Z N

Manifold

Size
02 = 2-place mounting rail
Description 04 = 4-place mounting rail
06 = 6-place mounting rail
For B-doser metering devices, manifolds 0202 = 4-place mounting rail, 2 places on opposite sides
0303 = 6-place mounting rail, 3 places on opposite sides
utilized are for 1 to 6 screw-in points with
thread G 1/8 for O-ring sealing Mainline Material
fitting for G 1/4 for ø 8 mm or pipe ø 1/2 in ZN = Zinc-coated and yellow-passivated steel
Normal profile and opposite-side profile
design manifolds are available in zinc-coated
and yellow-passivated steel Various designs
of main line and feed line connection can be
selected by order code

131
Metering device
Metering devices for grease

LG-doser

Description
Technical data
LG-dosers are used in single-line lubrication applications. The doser
Function principle metering device
group consists of a mounting rail with one or more dosers attached Outlets 1 to 6
to it. Dosing modules and mounting rails are made of stainless steel. Metering quantity 0,02 to 0,50 cm 3
0.0012 to 0.0305 in 3
Lubricant oil and grease NLGI 000 to 1
Features and benefits Operating temperature –25 to +80 °C; –13 to +176 °F
Operating pressure max 150 bar, 2 180 psi
• Two adjustable doser sizes are selectable Relief pressure LG001 = 10 bar; 145 psi
LG002 = 5 bar; 72 psi
by the used output quantity Materials stainless steel AISI 304
Connection main line (manifold) R 1/4 in
• Manifold material: stainless steel AISI 303 Connection outlet pipe connector ø 4 and 6 mm
• Compatible with screw-in type fittings or pipe ø 1/4 in
Connection lubricant point solderless pipe connection
for dosers and manifolds (DIN 3862)
Materials stainless steel AISI 303
• Suitable for feed line ø 4 and ø 6 mm Dimensions min 15 × 112 × 15 mm
• Robust and reliable max 17 × 110 × 17 mm
min. 0.6 × 4.4 × 0.6 in
max. 0.7 × 4.3 × 0.7 in
Mounting position any
Applications
• Food and beverage

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1276 EN
3D
skf-lubrication partcommunity com/3d-cad-models

132
Metering device

Metering devices for grease


LG-doser
Identification code L G – – –

Product series

Doser size
001 = 0,02 to 0,20 cm 3
0.0012 to 0.0122 in 3
002 = 0,20 to 0,50 cm 3
0.0122 to 0.0305 in 3
Material
S = stainless steel AISI 304
Lubricant outlet
4 = pipe connector ø 4 mm
6 = pipe connector ø 6 mm
U = lubrication pipe ø 1/4 in

Accessory

Manifold
Identification code B P L D – – S
Manifold

Size
02 = 2-place mounting rail
04 = 4-place mounting rail
06 = 6-place mounting rail
0303 = 6-place mounting rail, 3 places on opposite sides
Description
Material
For LG-doser metering devices, manifolds
S = stainless steel AISI 303
utilized are for 1 to 6 screw-in points with
thread G 1/8 for O-ring sealing Normal
profile and opposite-side profile design
manifolds are available in stainless steel
AISI 303 Various designs of main line
and feed line connections can be selected
by order code

133
Metering device
Metering devices for grease

SL-32HV

Description
Technical data
The series SL-32HV (high venting) metering devices are for sin-
gle-line, high-pressure centralized lubrication systems dispensing Function principle metering device
Outlets 1 to 10
petroleum-based lubricants with a viscosity up to NLGI 2 (refer to Metering quantity 0,016 to 0,131 cm 3
Design Guide) Output is externally adjustable The indicator stem 0.001 to 0.008 in 3
Lubricant grease NLGI 0, 1, 2
permits visual check of metering device operation Individual meter-
Operating temperature max +93 °C; +200 °F
ing devices can be removed easily for inspection or replacement Operating pressure 83 to 240 bar, 1 200 to 3 500 psi
Relief pressure 28 bar, 400 psi
Material carbon steel, nitrile packings
Features and benefits Connection main line 1/4 NPTF (F), 1/4 NPTF (M)
Connection outlet 1/8 in O D tube
• Shipped with manifolds from 1 to 10 ports Lubricant point solderless pipe connection (DIN 3862)
to match number of lube points Dimensions min 44,5 × 93 × 52 mm
max 215 × 93 × 52 mm
• Output is externally adjustable min. 1.8 × 3.6 × 2.1 in
• Indicator stem permits visual check of operation max. 8.5 × 3.6 × 2.1 in
Mounting position any
• Can be removed easily for inspection or replacement
• Available in stainless steel SAE 304

Applications
• Food and beverage, industrial automation
• Machine tools, oil and gas
• Steel industry, pulp and paper Order information
• Marine and forestry, construction
Order number Designation Outlet
• Wind energy, mobile on-road

83336HV-1 metering device 1


83336HV-2 metering device 2
NOTE 83336HV-3 metering device 3
Further technical information, technical drawings, 83336HV-4 metering device 4
accessories, spare parts or product function descriptions 83336HV-5 metering device 5
83336HV-6 metering device 6
available on SKF com/lubrication 83336HV-7 metering device 7
83336HV-8 metering device 8
83336HV-9 metering device 9
83336HV-10 metering device 10
83338HV metering device, single, no manifold 1
83337HV metering device, single replacement –

134
Metering device

Metering devices for grease


SL-1

Description
Technical data
The series SL-1 metering devices are for single-line, high-pressure
centralized lubrication systems dispensing lubricants compatible Function principle metering device
Outlets 1 to 6
with flouroelastomer packings and viscosity up to NLGI 2 Output is Metering quantity 0,131 to 1,31 cm 3
externally adjustable An indicator stem permits visual check of 0.008 to 0.080 in 3
Lubricant grease NLGI 0, 1, 2
metering device operation Individual metering devices can be ere-
Operating temperature -26 to +176 °C; -15 to +350 °F
moved easily for inspection or replacement Available in stainless Operating pressure 127 to 240 bar, 1 850 to 3 500 psi
steel SAE 316, for applications where environmental conditions are Relief pressure 41 bar, 600 psi
Material carbon steel, stainless steel 316
hazardous to carbon steel or in industries preferring stainless steel Connection main line 3/8 NPTF (F)
Connection outlet 1/8 NPTF (F)
Lubricant point solderless pipe connection
Features and benefits Dimensions min 63 × 179,4 × 52,4 mm
max 203 × 179,4 × 52,4 mm
• Shipped with manifolds from 1 to 6 ports (lubrication points) min. 2.5 × 7.0 × 2.0 in
• Output is externally adjustable max. 8.0 × 7.0 × 2.0 in
Mounting position any
• Each indicator stem permits visual check of injector operation
• Individual metering devices can be removed easily for
inspection or replacement
• Includes fitting for feed lines via alternate outlet port
• Available in stainless steel SAE 316

Applications Order information

• Mining and mineral processing Order number Designation Outlet


• Construction machinery, steel/heavy industry
81770-1 metering device 1
81770-2 metering device 2
NOTE 81770-3 metering device 3
Further technical information, technical drawings, 81770-4 metering device 4
accessories, spare parts or product function descriptions 81770-5 metering device 5
81770-6 metering device 6
available on SKF com/lubrication

135
Metering device
Metering devices for grease

QSL

Description
Technical data
QSL metering devices are designed for 300 bar pressure As a
Function principle metering device
result, NLGI 2 greases can be pumped at temperatures below zero Outlets 1 to 6
without problems All metering devices operate independently of Metering quantity 0,05 to 0,4 cm 3, 0.003 to 0.024 in 3
each other This means that in the event of a blockage or fault of Lubricant grease NLGI 0, 1, 2
Operating temperature –40 to +70 °C; –40 to +158 °F
one metering device, all other metering devices will continue to Operating pressure 140 to 300 bar, 2 030 to 4 350 psi
supply lubricant A control pin on top shows proper function of Relief pressure ≤ 60 bar, ≤ 870 psi
each metring device Materials steel, black cromated, polyurethane
Connection main line G 3/8 for steel pipe
16 × 2 mm; 0 63 × 0 08 in
Connection outlet G 1/8 for tubes/hoses
Features and benefits 4,1 × 2,3 mm; 0.16 × 0.09 in
Lubricant point solderless pipe connection, DIN 3862
• Suitable for use with manifolds from 1 to 6 ports to match or SKF quick connector
number of lube points; must be ordered separately Dimensions length: max 160 mm, 6.3 in
ø 28 mm; 1.1 in
• Corrosion-resistant, black-cromated or nickel-plated surface Mounting position any

• Each indicator stem permits visual check of operation


• Can be removed easily for inspection or replacement
• Controlled via main line

Applications
• Renewable energy
• Construction machinery
• Mining and mineral processing
• Compact and medium-sized machines and industrial applications NOTE
Further technical information, technical drawings,
• Commercial vehicles
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
12735 EN
3D
skf-lubrication partcommunity com/3d-cad-models

136
Metering device

Metering devices for grease


QSL
QSL order numbers

Order Designation Metering quantity Ring color


number 1) Injectors per stroke

cm 3 in 3

554-32810-1 QSL 0,05 0,05 0.00305 blue


554-32811-1 QSL 0,1 0,10 0.00610 white
554-32812-1 QSL 0,2 0,20 0.01220 yellow
554-32813-1 QSL 0,3 0,30 0.01830 red
554-32814-1 QSL 0,4 0,40 0.02440 green

1) In the case of backpressures in lubrication point lines of ≥ 100 bar or if several injectors are combined to one lubrication point,
use check valves, order number 223-12289-7

Accessory

Manifold, check valves and closure kit


Manifolds 1)

Order Designation Dimensions


number fixing hole length, total

mm in mm in

454-71505-1 divider bar, 2-fold 74 2.91 130 5.11


454-71506-1 divider bar, 3-fold 42 1.65 130 5.11
454-71507-1 divider bar, 4-fold 84 3.3 172 6.77
454-71508-1 divider bar, 5-fold 126 4.96 214 8.42
454-71509-1 divider bar, 6-fold 84 1) 3.3 256 10.07
Description
For QLS metering devices, manifolds utilized
are for 1 to 6 push-in points tightened by a
1) Instead of the planned injectors a divider bar can also be equipped with a closure kit 5, order number: 554-34387-1
hollow screw with thread G 3/8 for O-ring
sealing Normal profile design manifolds
are available in steel The main line Check valves and closure kit
connection G 3/8 is for steel pipe 16 × 2 mm
Order number Designation
(0.63 × 0.08 in) The lubrication connection is
for plastic tube 4,1 × 2,3 mm (0.16 × 0.09 in)
223-12289-7 check valves for connection at lubrication point outlets

554-34387-1 closure kit 5

137
Metering device
Metering devices for grease

VR

Description
Technical data
Product series VR are 1- to 12-port prelubrication metering devices
for single-line, centralized lubrication systems for fluid grease and Function principle block metering device
Outlets 1 to 12
grease up to NLGI 2 These metering devices are characterized by Metering quantity non-adjustable: 0,1 to 1,3 cm 3/min
an innovative, compact and sturdy design with SKF Quick Connector 0.006 to 0.079 in 3/ min
adjustable: 0,1 to 1,1 cm 3/min
systems
0.006 to 0.067 in 3/ min
Lubricant fluid greases and grease NLGI 0, 1, 2
Operating temperature –25 to +80 °C; –13 to +176 °F
Features and benefits Operating pressure 100 to 315 bar; 1 450 to 4 570 psi
Relief pressure 30 or 70 bar; 435 or 1 015 psi
• Innovative, extremely compact design Materials anodized aluminum, stainless steel,
• Optional metering devices for 1 to 12 ports FKM (FPM)
Connection main line G 1/4 for pipes 4 or 6 mm
to match number of lubrication points 0.16 or 0.24 in
• Metering nipples with indicator pin for visual Connection outlet G 1/8 for pipes 4 or 6 mm,
0.16 or 0.24 in
monitoring of each lubrication point Lubricant point solderless pipe connection (DIN 3862)
Dimensions depending on model:
• Optional push-in type or screw-in type fittings min 97 × 130 × 54 mm;
for feed line or main line connections are selectable max 281 × 121 × 119 mm;
min. 3.82 × 5.12 × 2.13 in
• Easy metering adjustment by replacing the metering nipples max. 11.06 × 4.76 × 4.68 in
• Black anodized surface for optimized corrosion protection Mounting position any

• Suitable for corrosivity category C3 and C5 per


DIN EN ISO 12944 and certified by Germanischer Loyd
• High functional reliability when using stiff greases
at low working temperatures

Applications NOTE
• Onshore and offshore wind energy systems Further technical information, technical drawings,
• Construction machinery accessories, spare parts or product function descriptions
available on SKF com/lubrication:
• Steel industry
1-5001-EN, 951-230-007
• Heavy industry
3D
• General mechanical engineering applications
skf-lubrication partcommunity com/3d-cad-models

138
Metering device

Metering devices for grease


VR
Identification code V R

Product series

Number of metering points 1 2 3 4 5 6 7 8 9 10 11 12


01 = 1 07 = 7
02 = 2 08 = 8
03 = 3 09 = 9
04 = 4 10 = 10
05 = 5 11 = 11

Code letter

Metering quantity letter


(0 = not present, e g for VR06 assign 0 for metering points 7–12)

Code for fittings for main line connection


06 = 6 12 = 12

Design for fluid grease and grease

Design code A B C D E F G H N P
Max relief pressure [bar] 30 70 30 70 30 70 30 70 30 70
Secondary line connection G 1/8 G 1/8 VS VS VS VS G 1/8 G 1/8 SRV1) SRV1)
Secondary line ø [mm] – – 4 4 6 6 – – 6 6
Corrosivity category 2) C3 C3 C3 C3 C3 C3 C5-M C5-M C5-M C5-M

1) SRV = cutting-sleeve screw union, see page 2


2) Corrosivity categories per DIN EN ISO 12944 (certified by Germanischer Lloyd)

Metering

Metering quantity letter A 1) B 1) D 1) F 1) H 1) J 1) M 1) R 2) X


Metering [cm 3] 0,1 0,2 0,4 0,6 0,8 1 1,3 0,1–1,1 Closed

1) Fixed metering with indicator pin for visual function monitoring


2) Adjustable metering with indicator pin for visual function monitoring

Order example Fittings for main line connection


Left Right ø Main
fitting fitting line [mm] Code

Cutting-sleeve Cutting-sleeve 8 A
screw union * screw union * 10 G

Cutting-sleeve Closed 8 B
screw union * 10 H
Left Right Closed Cutting-sleeve 8 C
screw union 10 J

E0-2 screw union E0-2 screw union 8 D


10 K
VR06FFFFFFF000000Z E0-2 screw union Closed 8 E
• Single-line distributor, 6-port 10 L
• Relief pressure max 70 bar
• Lubrication point line connection using SKF plug connector Closed E0-2 screw union 8 F
for pipe ø 6 mm 10 M
• Metering quantity 1 – 6 = 0,6 cm
• Without fitting for main line connection (G 1/4 thread)
G 1/4 G 1/4 – Z

139
Metering device
Metering devices for grease

SLC

Description
Technical data
The SKF Lincoln SLC metering device is designed for use in
high-pressure singleline lubrication systems and features a modular Function principle block metering device
Outlets SLC1: 1 to 12
design Also, delivery volume can be adjusted via metering screws to SLC2: 1 to 6
ensure each lubrication point receives the required amount of lubri- Metering quantity optionally adjustable or fixed
SLC1: 0,1–0,7 cm3/stroke;
cant Featuring a spring-reset control piston, the metering device
0.006–0.042 in3/stroke
has a high venting capability compatible with greases up to NLGI 2 SLC2: 0,2–1,4 3/stroke;
The SLC offers easy configuration to meet your needs, including dif- 0.012–0.084 in3/stroke
Lubricant grease up to NLGI 2
ferent output quantity, fitting and adjustment options With the most Operating temperature –40 to +100 °C; –40 to +212 °F
compact construction in its class, the SLC is suitable for many appli- Operating pressure 150 to 315 bar; 2 175 to 4 570 psi
cations in renewable energy, construction, mining as well as in Relief pressure 68 bar; 990 psi
Materials steel
heavy industry Corrosion protection class C3-High, C4-Medium
(DIN EN ISO 12944)
Dimensions SLC1:
Features and benefits min 75 × 50 × 80 mm
max 215 × 50 × 180 mm
• High venting capability min. 2.95 × 1.97 × 3.15 in
max. 8.46 × 1.97 × 7.08 in
• Wide delivery volume range SLC2:
• Compact construction min 75 × 40 × 80 mm
max 215 × 40 × 205 mm
• Easy to monitor and maintain min. 2.95 × 1.57 × 3.15 in
max. 8.46 × 1.57 × 8.07 in
• Simplified failure analysis Mounting position any, preferably vertical
• Reduced risk of leaks
• Reliable operation in harsh conditions with
a wide operating temperature range
• Patented design and functionality
• Easy to clean
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
Applications available on SKF com/lubrication:
• Renewable energy 17717EN
• Construction and mining 3D
• Heavy industry skf-lubrication partcommunity com/3d-cad-models

140
Metering device

Metering devices for grease


SLC
Identification code S L C 3 – –
1 2 3 4 5 6 L R

Product series section

Doser size
1 = SLC1 (1–2 outlets per section)
2 = SLC2 (1 outlet per section)
Main line connections
G = BSP thread for metric tubing
A = NPTF thread for imperial tubing
Corrosion protection class
3 = C3-H, C4-M
Layout variants
A = Top: stroke adjustment
B = Top: stroke adjustment, buttom: visual memory indicator
C = Top: stroke adjustment, buttom: electrical performance detector
D = Buttom: stroke adjustment
E = Top: electrical performance detector, buttom: stroke adjustment
Metering quantity
SLC1 single outlet/section version: SLC1 twin outlet/section version: SLC2 single outlet/section version:
1 = 0,2 cm3/stroke; 0,012 in3/stroke B = 0,1 cm3/stroke; 0,006 in3/stroke 1 = 0,2 cm3/stroke; 0,012 in3/stroke
2 = 0,3 cm3/stroke; 0,018 in3/stroke C = 0,15 cm3/stroke; 0,009 in3/stroke 2 = 0,3 cm3/stroke; 0,018 in3/stroke
3 = 0,4 cm3/stroke; 0,024 in3/stroke D = 0,2 cm3/stroke; 0,012 in3/stroke 3 = 0,4 cm3/stroke; 0,024 in3/stroke
4 = 0,5 cm3/stroke; 0,030 in3/stroke E = 0,25 cm3/stroke; 0,015 in3/stroke 4 = 0,5 cm3/stroke; 0,030 in3/stroke
5 = 0,6 cm3/stroke; 0,036 in3/stroke F = 0,3 cm3/stroke; 0,018 in3/stroke 5 = 0,6 cm3/stroke; 0,036 in3/stroke
6 = 0,8 cm3/stroke; 0,048 in3/stroke G = 0,4 cm3/stroke; 0,024 in3/stroke 6 = 0,8 cm3/stroke; 0,048 in3/stroke
7 = 1,0 cm3/stroke; 0,060 in3/stroke H = 0,5 cm3/stroke; 0,030 in3/stroke 7 = 1,0 cm3/stroke; 0,060 in3/stroke
8 = 1,2 cm3/stroke; 0,072 in3/stroke K = 0,6 cm3/stroke; 0,036 in3/stroke 8 = 1,2 cm3/stroke; 0,072 in3/stroke
9 = 1,4 cm3/stroke; 0,084 in3/stroke L = 0,7 cm3/stroke; 0,042 in3/stroke 9 = 1,4 cm3/stroke; 0,084 in3/stroke
S = adjustable 0,2–1,4 cm3/stroke; R = adjustable 0,1–0,7 cm3/stroke; S = adjustable 0,2–1,4 cm3/stroke;
0,012–0,084 in3/stroke 0,006–0,042 in3/stroke 0,012–0,084 in3/stroke
V = reserve outlet, closed X = no metering section V = reserve outlet, closed
Z = adjustable, reserve outlet, closed Z = adjustable, reserve outlet, closed
X = no metering section X = no metering section
Lubricant inlet connections, main line
X = no fitting
A = ∅8 mm tube straight fitting, ferrule and nut O = ∅8 mm tube adjustable elbow fitting, ferrule and nut
B = ∅8 mm tube straight fitting, EO2 seal P =∅8 mm tube adjustable elbow fitting, EO2 seal
C = ∅8 mm tube straight fitting without ferrule and nut R = ∅8 mm tube adjustable elbow fitting without ferrule and nut
D = ∅10 mm tube straight fitting, ferrule and nut S = ∅10 mm tube adjustable elbow fitting, ferrule and nut
E = ∅10 mm tube straight fitting, EO2 seal T = ∅10 mm tube adjustable elbow fitting, EO2 seal
F = ∅10 mm tube straight fitting without ferrule and nut U = ∅10 mm tube adjustable elbow fitting without ferrule and nut
G = ∅12 mm tube straight fitting, ferrule and nut V = ∅12 mm tube adjustable elbow fitting, ferrule and nut
H = ∅12 mm tube straight fitting, EO2 seal W = ∅12 mm tube adjustable elbow fitting, EO2 seal
I = ∅12 mm tube straight fitting without ferrule and nut Y = ∅12 mm tube adjustable elbow fitting without ferrule and nut
K = ∅10 mm tube banjo fitting, ferrule and nut
L = ∅10 mm tube banjo fitting without ferrule and nut Z = closure plug
M = ∅12 mm tube banjo fitting, ferrule and nut
N = ∅12 mm tube banjo fitting without ferrule and nut
Lubricant outlet connections, feed line
SLC1G: SLC1A: SLC2G: SLC2A:
X = no fitting X = no fitting X = no fitting X = no fitting
A = ∅6 mm tube plug in fitting R = ∅1/4 tube plug in fitting A = ∅6 mm tube plug in fitting
R = ∅1/4 tube plug in fitting E = ∅8 mm tube plug in fitting
I = ∅10 mm tube plug in fitting

141
Metering device
Metering devices for grease

SL-11

Description
Technical data
Series SL-11 metering devices are for single-line, high-pressure
Order number 85497
centralized lubrication systems dispensing lubricants compatible
with flouroelastomer packings and viscosity up to NLGI 2 Output is Function principle metering device
externally adjustable An indicator stem permits visual check of Outlets 1
Metering quantity 0,82 to 8,2 cm 3
metering device operation Available only as single unit with 1/2 inch 0.050 to 0.500 in 3
NPTF (F) inlet Lubricant grease NLGI 0, 1, 2
Operating temperature -40 to +93 °C; -40 to +200 °F
Operating pressure 70 to 240 bar, 1 000 to 3 500 psi
Features and benefits Relief pressure 55 bar, 800 psi
Materials carbon steel, FKM, PTFE
Connection main line 1/2 NPTF (F)
• Output is externally adjustable
Connection outlet 1/4 NPTF (F)

• Indicator stem permits visual check of injector operation Lubricant point solderless pipe connection (DIN 3862)
or plug connector
• May be combined in a circuit of metering devices SL-32, Dimensions 73 × 241 mm
2.87 × 9.48 in
SL-33, SL-V XL, SL-V and/or SL-1 Mounting position any
• Can be removed easily for inspection or replacement
• Includes fitting for filling feed lines via alternate outlet port
• Available in stainless steel SAE 316

Applications
Metering devices have flouroelastomer packings Check packing compatibility with synthetic
lubricants; metering devices supplied with fitting for filling feed line via alternate outlet port
• Construction machinery Output with adjustment screw hand-tightened is 0,82 cm 3 (0.05 in 3); maximum output is
achieved with 11 1/2 turns at 0,66 cm 3/turn (0.04 in 3/turn).
• Mining and mineral processing
• Steel industry
NOTE
• Heavy industry
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

142
Metering device

Metering devices for grease


SL-V

Description
Technical data
Series SL-V metering devices are for single-line, high-pressure
Function principle metering device
centralized lubrication systems dispensing lubricants compatible with Outlets 1 to 6
polyurethane seals up to NLGI 2. Output is externally adjustable. An Metering quantity 0,25 to 1,31 cm 3
indicator stem permits visual check of metering device operation. 0.015 to 0.08 in 3
Lubricant grease NLGI 0, 1, 2
Individual metering devices can be removed easily for inspection or Operating temperature max +82 °C; +180 °F
replacement. Each SL-V metering device includes a clear, polycar- Operating pressure 128 to 413 bar, 1 850 to 6 000 psi
bonate protective cap. typical: 172 bar, 2 500 psi
Relief pressure 70 bar, 1 000 psi
Materials carbon steel
Connection main line 3/8 NPTF (F)
Features and benefits Connection outlet 1/8 NPTF (F)
Dimensions min 63 × 222 × 35 mm
• Shipped with manifolds from 1 to 6 ports max 203 × 222 × 35 mm
• Output is externally adjustable min. 2.5 × 8.7 × 1.4 in
max. 6.1 × 8.7 × 1.4 in
• Clear, polycarbonate protected cap over indicator stem permits Mounting position any
visual check of operation
• Can be removed easily for inspection or replacement Metering device manifolds have 10,3 mm (0.4 in) dia mounting holes for 9,5 mm (0.375 in) bolt;
• Available in carbon steel or stainless steel SAE 304 metering devices have polyurethane seals; check compatibility with synthetic lubricants;
metering devices include fitting for filling feedlines via alternate outlet port; output with
• Output setting system by a set of color-coded sleeves adjustment screw hand-tightened is 0,246 cm 3 (0.015 in 3); maximum output is achieved
with five turns at 0,229 cm 3/turn (0.014 in 3/turn).

Applications
Order information
• Construction machinery
• Mining and mineral processing Order
• Steel industry number Outlets Designation

85770-1 1 Metering device incl manifold


NOTE 85770-2 2 Metering device incl manifold
Further technical information, technical drawings, 85770-3 3 Metering device incl manifold
85770-4 4 Metering device incl manifold
accessories, spare parts or product function descriptions 85770-5 5 Metering device incl manifold
available on SKF com/lubrication 85770-6 6 Metering device incl manifold
85771 1 Replacement metering device for manifold
85772 1 Single metering device, no manifold
inlet 3/8 NPTF (M)

143
Metering device
Metering devices for grease

SL-V XL

Description
Technical data
Series SL-V XL high-output metering devices are for single-line,
Function principle metering device
high-pressure centralized lubrication systems dispensing lubricants Outlets 1 to 6
compatible with polyurethane seals up to NLGI 2 Output is externally Metering quantity 0,25 to 5,00 cm 3, 0.015 to 0.305 in 3
adjustable An indicator stem permits visual check of metering device Lubricant grease NLGI 0, 1, 2
Operating temperature –40 to +82 °C; –40 to +180 °F
operation Individual metering devices can be removed easily for Operating pressure 128 to 413 bar; 1 850 to 6 000 psi
inspection or replacement Two SL-V XL metering devices are Relief pressure 70 bar, 1 000 psi
required to replace one SL-11 metering device Each SL-V XL meter- Materials carbon steel
Connection main line 3/8 NPTF (F)
ing device includes a clear, polycarbonate protective cap Connection outlet 1/8 NPTF (F)
Lubricant point solderless pipe connection (DIN 3862)
or plug connector
Features and benefits Dimensions min 63 × 284 × 35 mm
max 203 × 284 × 35 mm
• Suitable for use with manifolds from 1 to 6 ports to min. 2.5 × 11.2 × 1.4 in
max. 6.1 × 11.2 × 1.4 in
match number of lubrication points Mounting position any
• Output is externally adjustable
• Includes a clear, polycarbonate protective cap over indicator stem
that permits visual check of operation
• Can be removed easily for inspection or replacement
• Includes fitting for filling feed lines via alternate outlet port
Metering device manifolds have 10,3 mm (0 4 in) dia mounting holes for 9,5 mm (0.375 in) bolt;
• Available in carbon steel or stainless steel SAE 304 metering devices have polyurethane seals Check compatibility with synthetic lubricants;
metering devices include fitting for filling feed lines via alternate outlet port; output with
adjustment screw hand-tightened is 0,246 cm 3 (0.015 in 3); maximum output is achieved with
20 5 turns at 0,229 cm 3/turn (0.014 in 3/turn)
Applications
• Construction machinery
NOTE
• Mining and mineral processing Further technical information, technical drawings,
• Heavy industry accessories, spare parts or product function descriptions
available on SKF com/lubrication

144
Metering device

Metering devices for grease


SL-V XL
Identification code 8 5 7 8 –

Product series, carbon steel


85780 = metering device incl. manifold, 3/8 NPTF (M) inlet
85781 = replacement for manifold metering device (only one outlet possible)
85782 = single metering device, no manifold, 3/8 NPTF (M) inlet (only one outlet possible)
Outlets
1=1
2=2
3=3
4=4
5=5
6=6

145
Control units

146
Overview of control units

Control units

Control units
Product Operating Supply voltage Adjustable Level Page
temperature max. monitoring

°C °F V DC V AC

EXZT2A02 0 to 60 +32 to 140 12/24 120 • – 148


EXZT2A05 0 to 60 +32 to 140 12/24 120 • • 148
EXZT2A07 0 to 60 +32 to 140 12/24 120 • • 148

IGZ36-20 0 to 60 +32 to 140 12/24 120 • – 148


IGZ36-20-S6 0 to 60 +32 to 140 12/24 120 • • 148
IGZ38-30 0 to 60 +32 to 140 12/24 120 – • 148
IGZ38-30-S1 0 to 60 +32 to 140 12/24 120 – • 148
IGZ51-20-S3 0 to 60 +32 to 140 12/24 120 – – 148

IG502-2-E -25 to +75 -13 to +167 12/24 – • • 150


LC502 0 to 60 +32 to 140 12/24 – • • 151

ST-2240-LUB 0 to 50 +32 to 140 – 132/264 • • 152


ST-1240 0 to 50 +32 to 140 – 132/264 • • 153
ST-1100i -20 to +60 -4 to +142 – 93-264 • • 154
ST-102 -40 to +80 -40 to +176 12/24 – • • 155
ST-102P -40 to +80 -40 to +176 12/24 – • • 156

84501 -18 to +54 0 to +130 – 120/230 • – 157


84015 -18 to +55 0 to +131 12/24 – • – 158
85520 -25 to +65 -13 to +150 – 120 • • 159
85535 -40 to +65 -40 to +150 12/24 – • • 152

LMC 101 -40 to +65 -40 to +150 12/24 – • • 161


EOT-1 -25 to +70 -13 to +158 12/24 – • • 162
EOT-2 -25 to +70 -13 to +158 12/24 – • • 162

LMC 301 -40 to +70 -40 to +158 24 90–264 • • 164


LMC 2 -10 to +70 +14 to 158 12/24 230 • • 163

LRM 2 -30 to +70 -22 to +158 12/24 – • • 166

Control unit kits

Product Designation Operating Voltage Adjustable Level Page


temperature max monitoring

°C °F V DC V AC

85525 Kit: controller and pressure sensor -25 to +65 -13 to +150 – 120 • • 160
85208 Kit: controller, pressure sensor, solenoid valve 0 to +50 +32 to +122 – 110/120 • • –
85209 Kit: controller, pressure sensor, solenoid valve 0 to +50 +32 to +122 – 220 • • –

Connection and flow control units

Product Designation Operating Voltage Page


temperature max

°C °F V DC V AC

HCC Hose tear-off control -25 to +70 -58 to +158 12/24 – 160
Flow sensor Flow sensor +10 to +50 50 to 122 12/24 – 182

147
Control unit

EXZT / IGZ
Control units

Description
Technical data
Universal electronic control and monitoring devices are used in
single- line and progressive lubrication systems for stationary Function principle universal electronic control
industrial applications, installed in a switching cabinet or internally and monitoring device
Operating temperature 0 to 60 °C; +32 to 140 °F
in a compact lubrication unit Two different versions are required: Output voltage 24 V DC +10% /-15%
+471 for 100 to 120 V AC and 200 to 240 V AC; and +472 for 24 V DC Connector for class II
Protection class IP 30, clamps IP 20
and 24 V AC The universal devices can be used as time-dependent Dimensions 70 × 75 × 110 mm
or pulse-dependent controllers The main task is to initiate a lubrica- 2.7 × 3 × 4.3 in
tion cycle after a set time The devices also monitor the piston strokes
Version + 471
and run the pump during the lubrication time in clogged operation Input voltage 100 – 120 V AC; 200 – 240 V AC
All devices have custom- built functions integrated and can be con- Input current rated 70 mA / 35 mA
figured to meet the requirements of the application Mentioned Power input 8W
Frequency 50 – 60 Hz
device models must be selected based on their special function con- Fuse max 6 3 A
figuration and additional features according to the user manual Switching current max 5 A
Input voltage sensors 24 V DC

Features and benefits Version + 472


Input voltage 20 to 24 V DC; 20 to 24 V AC
• Easy installation via top hat rail mounting Input current rated 75 mA at max fan-out of 250 mA
• One unit for different operating modes such as timer, Power input 5W
counter and monitoring functions; other Frequency DC or 50 – 60 Hz
Fuse max 6 3 A
features are adjustable Switching current max 5 A
• Pulse generator/counter with adjustable interval time Input voltage sensors 24 V DC
• Time operation or machine clogged operation
• Pump run time limitation
• Monitoring of pressure build-up, contact (NO)
• Low-level control and EEPROM as an additional feature
NOTE
Applications Further technical information, technical drawings,
• All single-line lubrication systems for stationary accessories, spare parts or product function descriptions
industrial applications available on SKF com/lubrication:
1-1700-4-EN, 951-180-001

148
Control unit

EXZT / IGZ
Order information

Control units
Monitoring Lubricant Early Adjustable
Adjustable Adjustable of pressure level Interval lubricant level failure
Input monitoring pump delay relief, monitoring, time warning, Pulse memor
Order number voltage time time contact contact extension contact monitoring EEPROM

EXZT2A02+471 120 V AC • • NO 1) NO 1) • – – –

EXZT2A02+472 24 V DC • • NO 1) NO 1) • – – –

EXZT2A05+471 120 V AC • • – NC 2) • – • –

EXZT2A05+472 24 V DC • • – NC 2) • – • –

EXZT2A07+471 120 V AC • • – NC 2) • • – –

EXZT2A07+472 24 V DC • • – NC 2) • • – –

IGZ36-20+471 120 V AC • • NC 2) NO 1) – – – –

IGZ36-20+472 24 V DC • • NC 2) NO 1) – – – –

IGZ36-20-S6+471 120 V AC • • NC 2) NC 2) – – – –

IGZ36-20-S6+472 24 V DC • • NC 2) NC 2) – – – –

IGZ38-30+471 120 V AC – – – NC 2) – – – –

IGZ38-30+472 24 V DC – – – NC 2) – – – –

IGZ38-30-S1+471 120 V AC – – – NO 1) – – – –

IGZ38-30-S1+472 24 V DC – – – NO 1) – – – –

IGZ51-20-S3+471 120 V AC • • NC 2) NO 1) • – – •

IGZ51-20-S3+472 24 V DC • • NC 2) NO 1) • – – •

1) NO = contact normally open


2) NC = contact normally closed

149
Control unit

IG502-2-E
Control units

Description
Technical data
The IG 502-2-E is a universal control and monitoring device for cen-
tralized lubrication in single-line and progressive lubrication sys- Function principle control unit
tems The compact device is equipped with a display panel for Control voltage max. 12 or 24 V DC
Contact load connector M 5 A at 12 or 24 V DC
parameter settings and function monitoring Different operating SL-output 4W
modes such as timer, counter and monitoring functions for pressure Protection class IP 20 DIN 40050, plug IP 00
Temperature range –25 to +75 °C; -13 to +167 °F
and cycle switches are programmable in their individual functions Storage temperature –40 to +75 °C; -40 to +167 °F
The display panel is protected against moisture and dirt A red LED Fuse protection max 5 A
shows faults as a collective message Two integrated electronic coun- Adjustable pause time 0,1 h to 99,9 h
Adjustable pump running time 0,1 min to 99,9 min
ters are used for permanent operation control and failed hours, Adjustable pulse time 1 to 999
where pump could not operate properly In both counters, saved Operation hours storage 0 to 99999,9 h
times cannot be deleted The working-hour meter summarizes times Operation- failed hours storage 0 to 99999,9 h
Dimensions 138 × 65 × 40 mm
when supply voltage at the device is switched on The device has its 5.43 × 2.56 × 1.57 in
own database independent of supply voltage for saving configuration
and parameters To avoid environmental influences, it is advisible to
install the device inside of a cabin
Order information

Features and benefits Order number Description

• Universal control and monitoring device


IG 502-2-E+912 Controller 12 V DC
• Compact design IG 502-2-E+924 Controller 24 V DC
• Easy to handle operations
• Different operating modes such as timer, 997-000-185 Wire set
counter and monitoring functions
• Red LED for failure indication and cause
• Integrated counters for permanent operation, failed hours and
working-hour meter show complete life cycle of system NOTE
Further technical information, technical drawings,
Applications accessories, spare parts or product function descriptions
• Commercial vehicles available on SKF com/lubrication:
• Construction machinery 951-180-002 EN
• Agriculture

150
Control unit

LC502

Control units
Description
Technical data
The compact LC502 is an all-purpose controller suitable for sin-
gle-line, progressive and dual-line systems Supplied as a separate Function principle control unit
unit or already integrated in the pump, this versatile controller Operating temperature 0 to +60 °C; +32 to 140 °F
Operating voltage
includes a basic power switch, motor circuit breaker (230/400 V AC 24 V DC 0,16 0,25 kW
types) start button and fault indicator light The unit’s user-friendly 230 V AC and 400 V AC 3-phase 0,15 0 85 kW
Operating voltage frequency 50 to 60 Hz
display enables input of customer-specific settings in up to seven Electrical connectors 4
languages (optional) Integration of the LC502, configuration of tech- Electrical output connectors 4
nical ratings and characteristics depend on the customer’s specific Input voltage 12 or 24 V DC
Protection class IP 54
application Off time (cycle) 8h
On time (pumping) 1h
Fuses
Features and benefits F1: 400 V AC and 203 V AC 5 × 20 mm / 4 A
F2: 400 V AC, 230 V AC 24 V DC 5 × 20 mm / 2 A
• Easy-to-operate, programmable controller Cycle settings dependent on time, machine pulse
pump revolutions
• System monitoring and error detection/failure remedy
Possible low-level controls: W1 wipe /dynamic
• Integrated temperature-overload safety device Possible low-level controls: W2 wipe /capacitive / static
• Up to three lubrication circuits can be controlled analog
Lubrication circuits max 2
or monitored separately Rotation 10 (for industry and vehicle pumps)
corresponds to 10 agitator rotations
Dimensions, for control cubicle 400 × 400 × 600 mm
Applications 15.75 × 15.75 × 23.62 in
Mounting position vertical, cable terminals pointing
• Special-purpose machinery and general industry downwards
• Cement and steel plants
• Food and beverage

Order information NOTE


Order number Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
24-1074-2270 LC 502; 24 V DC; 0,25 kW; for single-line systems 950-180-004-EN
24-1074-2240 LC 502; 230 V AC; 0,85 kW; for single-line systems

24-1074-2210 LC 502; 400 V AC; 0,85 kW; for single-line systems

151
Control unit

ST-2240-LUB
Control units

Description
Technical data
ST-2240-LUB-6 and ST-2240-LUB-14 lubrication control centers
are suitable for use in dual-line lubrication systems, as well as sin- Function principle control center
Operating temperature 0 to +50 °C, +32 to +122 °F
gle-line and progressive systems These units have a touchscreen Lubricant channels 1-14
display and are only differentiated by the cabinet size and maximum Supply voltage 115/230 V AC, automatic range selection
number of lubrication channels served The ST-2240-LUB-6 con- Supply voltage frequency 47 to 63 Hz
Control voltage 24 V DC, ± 10 %
trols up to 6 separate lubrication channels, while ST-2240-LUB-14 Overload protection automatic fuse, 6 A
controls up to 14 channels, each having independent lubrication Cable connection screw terminals for 2,5 mm2 wires
Protection class IP 65
parameters and/allows use of different lubricants if required The Interface 5 7” TFT touch screen , 320 × 240,
lubrication system is adjustable at field site by adding or reducing 64k colors, ethernet and USB port
channel modules, and configuration can be changed in the field by mobile app for monitoring
Data logging Log files on USB memory
the user Pressure switches and transmitters or piston detectors can Fieldbus ModbusTCP slave,
be used in all channels Also the new lubricant low level ultrasonic other protocols on request
sensor is supported Alarm Outputs relays K1 & K2: potential-free change
over contact; maximum load 230 V/1 A;
channel modules: potential-free contact;
maximum load 50 V DC/1A
Features and benefits Dimensions 600 × 600 × 250 mm
23.6 × 23.6 × 9.8 in
• Versatile and durable, automatic pump change (Dualset)
• Modular units provide easy system modification
• Compatible with ultrasonic low level sensor
• Grease spraying control with air monitoring
• Compatible with SKF doser monitor

Order information NOTE


Order number Designation Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF.com/lubrication:
12380760 ST-2240-LUB-6 control center
PUB LS/P2 17950 EN
12380765 ST-2240-LUB-14 control center

12501270 CM channel module

152
Control unit

ST-1240

Control units
Description
Technical data
The ST-1240 is a two-channel lubrication control
centre that supports any combination of single-line, dual-line Function principle control center
Operating temperature 0 to +50 °C, +32 to +122 °F
and progressive lubrication systems The lubrication channels Lubricantion channels 2
can be zones, separated by shut-off valves, or complete lubrication Supply voltage 93 to 132 V AC, 186 to 264 V AC
systems with separate pumping centres and varying lubricants Supply voltage frequency 47 to 63 Hz
Supply current 5,4 A/115 V AC, 2,2 A/230 V AC
Configuration can be set in the field by touchscreen display Control voltage 24 V DC, ± 10%

Overload protection automatic fuse, 6 A


Features and benefits Cable connection screw connections for 2,5 mm2 wires
Protection class IP 65
• Automatic pump change (Dualset) Interface touchscreen display
RS-422 port for SKF online software
• Grease spraying control with air monitoring Dimensions without cable 380 × 300 × 210 mm
glands 14.9 × 11.8 × 8.3 in
• IP 65 protection rating
• Compatible with SKF doser monitor
• Works with SKF online control software

Order information NOTE


Order number Designation Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF.com/lubrication:
12380210 ST–1240 GRAPH control centre
PUB LS/P8 12404/1 EN
12380220 ST-1240-IF control centre

153
Control unit

ST-1100i
Control units

Description
Technical data
SKF ST-1100i is an one-channel, microprocessor-based control
Function priciple control unit
centre for single-line, dual-line and progressive lubrication systems Operating temperature –20 to +60 °C; –4 to +142 °F
All lubrication configurations can be set in the field by user interface Lubricant oil and grease
The centre controls lubrication according to the desired settings, and Lubricant channels 1
Operating voltage 93 to 132 V AC, 186 to 264 V AC
lubrication events can be monitored Lubrication programming, Operating voltage frequency 50 / 60 Hz
alarm acknowledgements and lubrication event monitoring can be Control voltage 24 V DC, ± 10%
performed via both the control panel and the LED signals The con- Protection class IP 65
Interface 6-digit, 3-button user interface
trol panel is located inside the casing The user interface is a Lubrication cycle 0 min 00 s to 9 999 min
three-button, six-digit display and can be used for setting the default Pressurization 0 min 00 s to 999 min
values for the lubrication program and for turning on manual control Dimensions 200 × 300 × 120 mm
8.66 × 11.8 × 4.7 in
Mounting position vertical

Features and benefits


• Simple monitoring via control panel and cover LED signals
• All lubrication configurations can be set in field by user interface
• Set values and program status at the power failure are stored in
an EEPROM-memory; no battery

Applications
• Construction machinery, mining applications

Order information NOTE


Order number 1) Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
12380600 ST-1100i-ENG (menu: english language version) available on SKF com/lubrication:
13165 EN
12380692 ST-1100i-SS-ENG (menu: english language
version) stainless steel enclosure

1) Further product versions available on request

154
Control unit

ST-102

Control units
Description
Technical data
The ST-102 controller is designed for the control and monitoring
of single-line, dual-line and progressive lubrication systems in Function principle control and monitoring device
vehicles with a 12 or 24 V DC power supply It is a one-channel Operating temperature -30 to +80 °C; -22 to +176 °F
Power supply 12 and 24 V DC; (10,5 to 32 V DC)
lubrication control centre for systems with pneumatic or electrical Pump output control max 5 A
pumps The ST-102 is suitable for environments with temperatures Protection class IP 30
Self-setting fuse 4 A on pcb
ranging from -30 to +80 °C (-22 to +176 °F) and features an IP 30 Time, cycle settings:
protection class All lubrication configurations can be set in the field Max pressurization time 1 to 20 min
by the user Interval time 5, 10…120 min
Pressurization time 1,2,3…10 min
Interface 1-button user interface, 3 LED’s
Features and benefits Input 4 digital
Output 4 digital
• Available for 12 or 24V DC Standard CE
• Suitable for operational environments Dimensions 26 × 60 × 160 mm
1.02 × 2.36 × 6.3 in
with extreme temperatures Mounting position vertical
• One-button user interface
• Power failure memory

Applications
• Vehicles
• Construction machinery
• Agriculture

Order information NOTE


Order number Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
11500610 ST-102 for progressive and single-line systems available on SKF com/lubrication:
6408 EN

155
Control unit

ST-102P
Control units

Description
Technical data
The ST-102P one-channel lubrication control centre is designed
Function principle control unit
for the control and monitoring of lubrication systems in 12V DC or Operating temperature –40 to +80 °C
24V DC vehicles It supports single-line and dual-line lubrication –40 to +176 °F
systems All lubrication configurations can be set in the field by the Operating voltage 12 or 24 V DC (10,5 to 32 V DC)
Pump output control max 5 A
user The ST-102P casing has an IP 65 rating Protection class IP 65
Self-setting fuse 4 A on printed circuit board
Time, cycle settings:
Features and benefits Pressurization time 1 to 20 min
Interval time 5, 10…120 min
• Designed for control and monitoring in Interface 1-button user interface, 3 LEDs
Dimensions 67 × 80 × 170 mm
12/24 V DC lubrication systems
2.64 × 3.14 × 6.7 in
• Reliable and durable, one-channel lubrication controller Mounting position vertical

• Supports single-line and dual-line lubrication systems


• All lubrication configurations can be set in the field by user
• IP 65 rating Order information

Order number Designation


Applications
11500608 ST-102P-PS TIMER
• Control of lubrication systems with pneumatic pump
SKF 40PGAS and electrical pump SKF Minilube
• Small excavators
• Wheel loaders,
• Trucks and buses
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
13165 EN

156
Control unit

84501

Control units
Description
Technical data
Model 84501 program timer is used to control the lubrication cycle
Order number 84501
frequency of air-operated, single-stroke pumps The timer turns
pump on/off at programmed intervals via a 3-way or 4-way air sole- Function principle control unit
noid valve (not included) installed in the air line to the pump It is Operating temperature –18 to +54 °C; 0 to +130 °F
Operating voltage 120/230 V AC
capable of retaining memory for three hours during machine shut Operating voltage frequency 50/60 Hz
down or power failure Timing is suspended during power interrup- Switch capacity 120 V AC: 5 A
tions This feature eliminates over-lubrication due to pre-lube when 230 V AC: 1,5 A
Off-time cycle min 20 sec; max 24 h
machine is frequently started and stopped Using two programmable Off-time pumping min 10 sec; max 1 min 24 sec
jumper pins, four options are available with the memory and prelube Prelube on time 40 sec
feature Protection class NEMA 1
Standards UL, CSA
Dimensions 173 × 210 × 125 mm
7 × 8 × 5 in
Features and benefits Mounting position vertical

• Program timer controls lubication cycle frequency


of air-operated, single-stroke pumps
• Timer turns pump on/off via solenoid air valves
in programmed intervals
• Retains memory for three hours during machine
shut down or power interruption
• Suspended timing during power interruptions eliminates
over-lubrication due to pre-lube when machine is frequently
started and stopped

Applications NOTE
Further technical information, technical drawings,
• Cement industry accessories, spare parts or product function descriptions
• Food and beverage available on SKF com/lubrication
• Assembly lines
• Conveyors

157
Control unit

84015
Control units

Description
Technical data
Model 84015 is a 12/24 V DC-powered, solid-state controller for
Order number 84015
lubrication systems It is microprocessor-based and can be used
for automatic lubrication systems on mobile equipment or where Function principle control unit
AC power is not available Its rugged construction with liquid- and Operating temperature –18 to +55 °C; 0 to +131 °F
Operating voltage 24 V DC, (10-30 V DC)
dust-tight enclosure includes a manual push-button for remote Operating current 25 mA 1)
initiation of a lubrication cycle The controller always will start with an Switch capacity 5A
“off-time” period Off-time cycle min 2,5 min; max 80 min
Off-time pumping fixed: 75 sec
Protection class NEMA 12
Off-time (cycle) 2) min 90 sec
Features and benefits max 80 min
On-time (pumping) fixed, 75 sec
• 12/24 V DC-powered, solid-state controller Dimensions 79 × 133 × 76 mm
3.1 × 5.2 × 3 in
• Microprocessor-based Mounting position vertical or horizontal
• For automatic lubrication systems on mobile equipment
• Rugged construction with liquid- and dust-tight enclosure

Applications
• Construction machinery
• Delivery trucks
• Buses, vehicles 1) Less load
2) Available selections are 2 5, 5, 10, 20, 40 or 80 min

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

158
Control unit

85520

Control units
Description
Technical data
Model 85520 is a microprocessor-controlled, 120 V AC unit It is
Order number 85520
fully programmable and can be used either as a timer or a control-
ler Controllers have a wider off-time range than timers and a Function principle control unit
memory switch to turn pre-lube option on or off The controller is Operating temperature –25 to +65 °C; –13 to 150 °F
Operating voltage 120 V AC
used to program the cycle frequency of a lubrication pump Lubri- Operating voltage frequency 50/60 Hz
cation cycles are determined by the setting of internal switches, Current consumption 20 mA (less external load)
and the cycle times are selected to meet system requirements Relay contact load 120 V AC: 2 amps inductive load
Relay contact alarm 120 V AC: 2 amps inductive load
During the “on” time, the air to the pump solenoid will be Off-timecycle min 30 sec; max 30 h
energized Off-time pumping min 30 sec; max 5 min
Protection class NEMA 12
Dimensions 125 × 191 × 89 mm
5 × 7.5 × 3.5 in
Features and benefits Mounting position vertical
• Microprocessor-controlled, 120 V AC unit
• Simple adjustment via dip switches and rotary switches
• Fully programmable
• Can be operated in timer or controller mode

Applications
• Paper converting
• Plastic processing
• Printing
• Packaging NOTE
• Metalworking Further technical information, technical drawings,
accessories, spare parts or product function descriptions
• Material handling equipment
available on SKF com/lubrication

159
Control unit

85525
Control units

Description
Technical data
Model 85525 is a microprocessor-controlled, 120 V AC unit that
Order number 85525
includes a pressure switch and mounting brackets It is fully pro-
grammable and can be used either as a timer or a controller Con- Function principle control unit
trollers have a wider off-time range than timers and a memory Operating temperature –25 to +65 °C; –13 to +150 °F
Operating voltage 120 V AC
switch to turn pre-lube option on or off The controller is used to Operating voltage frequency 50/60 Hz
program the cycle frequency of a lubrication pump Lubrication Operating current 20 mA (less external load)
cycles are determined by the setting of internal switches, and the Relay contact load 2 amps inductive load at 120 V AC
Relay contact alarm 2 amps inductive load at 120 V AC
cycle times are selected to meet system requirements During the Off-time (cycle) min 30 s, max 30 h
“on” time, the air to the pump solenoid will be energized The On-time (pumping) min 30 s, max 5 min
enclosed pressure switch senses supply line pressure rise/fall Protection class NEMA 12
Dimensions 125 × 191 × 89 mm;
to signal system operation to controller or system alarm 5 0 × 7 5 × 3 5 in
Mounting position vertical

Features and benefits Pressure switch 69630

• Microprocessor-controlled, 120 V AC unit Protection class housing and UL-listed


switching elements: NEMA 3
• Includes pressure switch and brackets
• Simple setting via dip switches and rotary switches
• Fully programmable
• Can be operated in timer or controller mode

Applications
• Paper converting
• Plastic processing NOTE
Further technical information, technical drawings,
• Printing accessories, spare parts or product function descriptions
• Packaging available on SKF com/lubrication
• Metalworking
• Material handling equipment

160
Control unit

LMC 101

Control units
Description
Technical data
LMC 101 is a universal control and monitoring device for single-line
and progressive lubrication systems In single-line systems, pressure Function principle control unit
switches or pressure transducers can be installed at the pump and/or IVoltage input 12 V DC and 24 V DC -20%/ +30%
Current consumption 60 mA (less external load)
end of the supply line While designed for off-the-road and mobile Vent relay contact 20 A at 30 V DC
equipment use, the controller can be used for any low-voltage lubri- Pump relay contact 2 A at 30 V DC
Alarm relay contact 2 A at 30 V DC
cation application Timer or controller mode can be set for both sys- Enclosure rating NEMA 12
tems The device features various alarm condition settings, including Operating temperature –40 to +65 °C; –40 to +150 °F
cycle frequency or alarm triggers Programming, data logging and Net weight 0,9 kg, 2 lbs
Off-time adjustable 15 sec to 99 h
reporting are possible, including system resets, downloads to con- On-time adjustable 15 sec to 99 h
trollers, lubrication activity, lubrication cycles and alarms The con- Lubrication systems single-line and progressive systems
troller must be programmed via USB connection to PC In timer Enclosure size 209 × 127 × 89 mm
8.25 × 5 × 3.50 in
mode, the lubrication cycle ends when pre-assigned time has Mounting dimensions 222 × 95 mm
expired In controller mode, the lubrication cycle ends when pressure 8.75 × 3.75 in
switch, pressure transducer or piston detector actuates System
allows pressure to dissipate to end of supply line once pressure
Order information
at pump is reached
Order number Designation

Features and benefits 86535 LMC 101 control unit for single-line
• Various alarm condition settings including cycle and progressive lubrication systems
frequency and alarm triggers
• Programming, data logging and reporting, including
system resets, downloads to controllers, lubrication activity,
lubrication cycles and alarms
• Display: LEDs, pump on and system fault (alarm)
• Controller must be programmed via USB connection to PC NOTE
• Manual lubrication push-button Further technical information, technical drawings,
accessories, spare parts or product function descriptions
Applications available on SKF com/lubrication:
• Off-highway vehicles 15625 EN
• Mobile equipment use 3D
skf-lubrication partcommunity com/3d-cad-models

161
Control unit

EOT-1/2 664-34135-6, 664-34135-7


Control units

Description
Technical data
EOT-1 / EOT-2 are time controllers for lubrication pumps in sin-
gle-line or progressive lubrication systems EOT-1 has a fixed run- Function principle control unit
ning time of 4 seconds and flexible pause time adjustments and, Supply voltage 12/24 V DC
Max current draw ≤ 7A
therefore, is suitable for chain lubrication EOT-2 features flexible Protection class IP 65 , SELV/PELV
time settings Both controllers are required if pumps without timers Operating temperature –25 to +70 °C; –13 to +158 °F
Noise suppression class A VDE 0875 T11
are used in lubrication systems or there is no customer-related Interference resistance DIN EN 61000-6-1
request for pumps with an integrated pump controller It also is suit- Transient emissions DIN EN 61000-6-3
able for retrofit installation Simply set time using the red (running Outputs transistor/ no
EEPROM non-dissipative storage of data
time) and a blue (pause time) switches and use the push-button to
activate an additional lubrication cycle for easy and safe pump EOT 1
operation Pause time min 5 sec, max 75 min
Running time 4 sec, unvaried
EOT 2
Features and benefits Pause time min 4 min, max 15 h
Running time min 8 sec, max 30 min
• Time controller for installation in driver's cabin
• Suitable for retrofit Factory setting
EOT 1
• Simple handling of time setting and function control Pause time 15 sec
Running time 4 sec
EOT 2
Applications Pause time 6 min
• Agriculture Running time 4 sec
• Chain lubrication systems Dimensions 122 × 118 × 56 mm
4.8 × 4.6 × 2.2 in
Mounting position any

Order information NOTE


Order number Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
664-34135-6 EOT 1 controller for SKF Lincoln EOP pumps available on SKF com/lubrication:
951-181-005 EN
664-34135-7 EOT 2 controller for one pump unit (not EOP)
3D
skf-lubrication partcommunity com/3d-cad-models

162
Control unit

LMC 2

Control units
Description
Technical data
The LMC 2 is a controller for the electronic management and moni-
Function principle electronic control unit
toring of lubrication systems It combines the advantages of a spe- Operating temperature –10 to +70 °C; +14 to +158 °F
cially developed printed circuit board (PCB) and a PLC in an economi- Inputs max 8 digital inputs
cal, compact unit Outputs 4 relay outputs, 1 electronic
Supply voltage depending on model:
230 V AC, 24 V DC
Protection class IP 54
Features and benefits Dimensions 200 × 120 × 90 mm
7.9 × 4.7 × 3.5 in
• Integrated, flexible lubrication programs Mounting position any
• 8 inputs / 5 outputs; suitable for complex lubrication systems
• Time- or cycle-dependent control of lubrication intervals
• Can be interfaced with common field bus systems

Applications
• Lincoln and SKF progressive systems, Order information
single-line, dual-line and multi-line systems
• Railway lubrication and spray lubrication systems Order number Designation
• Food and beverage
• Chain lubrication systems like Cobra and PMA 236-10567-6 LMC 2 230 AC (230 V AC)

236-10567-5 LMC 2 24 DC (24 V DC)

For use with electrically driven, 3-phase pump, a motor starter must be ordered separately

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
14004 EN
3D
skf-lubrication partcommunity com/3d-cad-models

163
Control unit

LMC 301
Control units

Description
Technical data
The LMC 301 is a compact, modularly expandable control and
Function principle electronic control unit
monitoring device The device is equipped with an LCD display and Operating temperature V AC –10 to +50 °C; +14 to +122 °F
six functional keys for programming, parameter setting and signali- Operating temperature V DC –40 to +70 °C; –40 to +158 °F
zation The user is guided through the setting menu Also, there is Inputs 10 count, short-ciruit
Outputs 8 counts, relay outputs NO-contact
a simple-to-use PC software for parameter setting and diagnostics 8 A, 2 of which up to 20 A
available Supply voltage depending on model:
90-264 V AC, 24 V DC ± 20%
Protection class IP 65
Features and benefits Dimensions 270 × 170 × 90 mm
10.7 × 6.7 × 3.5 in
• Integrated, flexible lubrication programs Mounting position vertical
• Basic device with 10 digital inputs, of which two
can be used analogously, and eight outputs
• Up to seven extension modules can be added, whereby each mod-
ule has 10 E 8 A just like the basic device
• Three lubrication pumps can be controlled and monitored, Order information
each of which provides up to three lubrication circuits Order number Designation
• Single modules are connected by a bus interface
086500 LMC 301; 24 V DC, master, incl LCD display
086501 LMC 301; 100-240 V AC, master, incl LCD display
086502 LMC 301; 24 V DC, I/O board, slave, without display
Applications 086503 LMC 301; 100-240 AC, I/O board, slave, without display
• Cement ans steel industry
• Mining; stationary and mobile excavators
• Food and beverage
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
15967 EN, 951-150-029 EN
3D
skf-lubrication partcommunity com/3d-cad-models

164
Control unit

LMC 301 - Accessories


LMC 301 motor relay assembly

Control units
Order number Description

236-10850-7 with motor starter 0,4–0,6 A


236-10850-8 with motor starter 0,6–1,0 A
236-10850-9 with motor starter 1,0–1,6 A
236-10980-6 with motor starter 2,4–4,0 A

LMC 301 housing

Order number Description

086504 door housing, complete


086505 cable USB

General LMC 301 accessories

Order number Description

PG-M20 Cable gland kit, IP 65


086506 Multiple cable gasket set (3 x)
086507 Cable gasket set (3 x)

Cable glands PG-M20; complete, with cap nut, cable gasket set, screw plug cartridge
3515-10-6020 Cable gasket set; 2-wire, ∅ 0 6 mm
3515-10-6620 Cable gasket set; 4-wire, ∅ 0 5 mm

3515-10-7620 Blind plug


3515-10-6320 Gasket
3515-10-6120 Counter nut

Conduit glands, IP 65, with flexible metal tube (FMC), UL approved


3515-07-6120 Conduit glands AMG-M 20 x 1,5; UL 514B
3515-10-2021 Counter nut M 20 x 1,5
3515-07-2022 Protection hose, liquid-proof protective; UL 360 (sold by the metre, when ordering specify the required length)
179-990-486 Fuse, blade-type, FK1 3A (32 V) according to ISO 8820-3
236-11066-1 Battery, 3 V lithium button cell, model CR3032

www skf com/LMC301 LMC 301 software, free download

1) The installation of the cable glands and cable sets to be provided and done by the customer The customer is responsible for proper installation

165
Control unit

LRM 2
Control units

Description
Technical data
SKF’s LRM2 lubrication remote monitor is designed for use with
lubrication systems that cannot be checked daily due to the nature or Function principle control unit with remote control
Operating temperature -30 to +70 °C; -22 to +158 °F
position of the specific application Compatible with oil or grease, the Storage temperature -40 to +70 °C; -40 to +158 °F
monitor can be used on single-line, dual-line and progressive lubri- Air humidity 0–95%
cation systems The LRM2 can communicate with a pump or group Protection class IP 66
Screwed cable gland M16
of pumps on the same type of lubrication system LRM utilizes a SIM Clamping zone of cable strand ∅4–10 mm; 0,16–0,39 in
card similar to those found in cell phones and tablets to send and LRM2 clamping zone 0,25–2,5 mm; 0.0098–0.098 in
Supply voltage 12–24 V DC (∓ 20%)
receive text messages via iOS or android mobile devices or via e-mail
Power consumption max 3 W
to a computer The monitoring system can transmit alert messages Min installation space 420 × 220 × 350 mm
to a random number of e-mail or mobile phone contacts These con-
Dimensions
tacts can be grouped based on the message type The LRM2 features LRM 2 without enclosure 150 × 90 × 61 mm;
two digital inputs and outputs and sends both low-level and fault 10.67 × 6.73 × 10.31 in
messages Also, the monitor can be used to start an additional lubri- Enclosure 271 × 171 × 262 mm
16.53 × 8.66 × 13.78 in
cation cycle and can be reset by sending messages from the mobile Mounting position any
device In addition, you can access system information by using your
web browser without having to install special software The LRM is
suitable for wind energy, railroad wayside, cable car and wastewater
treatment applications, as well as other industries

Features and benefits


• Two digital inputs and outputs
• Antenna is packed inside housing;
optional external antenna can be ordered
NOTE
• LRM2 module is available without housing
Further technical information, technical drawings,
for mounting in existing control box
accessories, spare parts or product function descriptions
are available on SKF com/lubrication
Applications PUB LS/P2 17887 EN; 951-181-022-EN
• Wind energy generators
• Wastewater treatment applications

166
Control unit

LRM 2
Identification code L R M 2 – – – 0 0

Control units
Lubrication Remote Monitor 2

Country code
A = USA (incl. UL/CSA/FCC/ US frequency band)
E = Europe and Asia (no UL/CSA/FCC)
Pump / product family
0 = P203, P603, P653 (without coupling relays)
1 = KFG (with coupling relays and always in enclosure) (2 coupling relays)
2 = If 2 AC pumps are switched to one LRM (4 coupling relays)
3 = If 3 AC pumps are switched to one LRM (6 coupling relays)
Programming
0 = Separate empty signal and fault signal (only on P-series, not with KFG pumps)
1 = Joint empty signal and fault signal (on KFG or P-series)
Enclosure
1 = with enclosure
0 = base unit only, without enclosure, no antenna

Order example Antenna

LRM2-E-01-100 • Lubrication Remote Monitor 2 Order number Designation


• For use in Europe and Asia
• Pump versions P203, P603, P653 236-11335-8 2G/3G Magnetic base antenna (3 m length)
• Joint empty signal and fault signal
• With enclosure

167
Pressure sensors

168
Overview of pressure sensors

Pressure sensors
Mechanical pressure sensors with digital output signal

Product Lubricant Pressure ranges Operating temperature Voltage Contact Page


oil/fluid type
grease grease

bar psi °C °F V DC V AC

DSA • – 1–30 14.5–435 +10 to +60 +50 to +140 – 250 change-over 170
DSD • – 0,5–45 7.25–653 -30 to +100 -22 to +212 36 – change-over 172
69630 • • 19–207 275–3 000 -25 to +65 -13 to +149 – 125/250/480 NO/NC 176

DSB – • 20–300 290–4 350 -25 to +80 -13 to +176 30 – change-over 174
234-10825-8 • • 100–400 1 450–5 800 -25 to +85 -13 to +185 30-250 125–250 change-over 177

Digital pressure sensors with digital output signal

Product Lubricant Pressure ranges Operating temperature Voltage Contact Page


oil/fluid type
grease grease

bar psi °C °F V DC V AC

DSC2 • – 0–40 0–580 -10 to +80 +14 to+176 18–30 – change-over 178
DSC3 • – 0–100 0–1 450 -25 to +80 -13 to +176 9–35 – change-over 179
234-11145-3/4/5/9 • • 0–400 0–5 800 -25 to +125 -13 to +257 18–36 – NO/NC 180

234-10330-4 • – 0–600 0–8 700 -20 to +85 -4 to +185 24 – NO/NC 181


234-13161-5/9 • • 0–600 0–8 700 -25 to +80 -13 to +176 20-32 – NO/NC 182
234-11272-4 • • 10–600 145–8 700 -25 to +100 -13 to +212 18-32 – NO/NC 183

DSC1 • – 0–40 0–580 -10 to +80 +14 to+176 10–32 – change-over 184

247333 • – 0–276 0–4 000 -29 to +82 -20 to +180 10–30 – transducer 185

169
Pressure sensor

DSA
Pressure sensors

Description
Technical data
SKF pressure switches of the DSA series monitor the pressure of a
Function principle pressure switch
centralized lubrication system to assess and help to ensure its proper Lubricant oil and fluid grease NLGI 000, 00, 0
function Important monitoring parameters in an intermittently oiled compressed air
operated centralized lubrication system with single-line metering Operating temperature +10 to +60 °C; +50 to +140 °F
Operating pressure 1) max 45 bar; max. 650 psi
devices are pressure buildup, pressure head and pressure reduction Switching pressure range 1 to 30 bar; 14.5 to 435 psi
Switch type micro switch
Contact type change-over
Features and benefits Contact rating max 125 VA
Switch current min 2 mA , max 300 mA
• Inexpensive mechanical diaphragm pressure switches Switching rate max 30 per min
• Micro switch is designed as a change-over switch and can Switching voltage max 250 V AC / 30 V DC
be used as both a normally closed contact (NC) and a normally Electrical connection 2) DIN EN 175301-803, plug
Connection fitting ø 6 mm; connector DIN 3862,
open contact (NO) for solderless pipe union,
• Switches are available for rising and falling pressures from plug connector for pipe
Materials:
1 to 30 bar (14.5 to 435 psi) and have non-adjustable increments
Housing PA6 6GF30
Contact AuAg25Pt6
Membrane FKM (FPM)
Applications Protection class with cable box IP 65
Safety class II
• Machine tools Dimensions min 76 × 120 × 41 mm
• Printing machines max 83 × 129 × 41 mm
• Wind min. 3.0 × 4.7 × 1.6 in
max. 3.3 × 5.1 × 1.6 in
• Vehicle Mounting position any
• Steel and heavy industries

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1701-EN
3D
1) A pressure-regulating valve must be installed in the system to prevent operating
skf-lubrication partcommunity com/3d-cad-models pressure from exceeding the permissible level
2) M 12x1 circular plug, only for design with electrical connection center

170
Pressure sensor

DSA

Pressure sensors
Identification code D S A 1 - W – A

Product series DS

Pressure switch type A

Switching direction
S = switch on increasing pressure
F = switch on decreasing pressure
Rated switching pressure
01 = 1 bar
02 = 2 bar
03 = 3 bar
05 = 5 bar
08 = 8 bar
12 = 12 bar
20 = 20 bar
25 = 25 bar
30 = 30 bar
Type of contact
W = change-over

Pressure port
1 = DIN 3862, ø 6 mm for solderless pipe union
2 = plug connector for pipe ø 6 mm
Position of electrical connection
M = middle
R = right
L = left
Electrical connection
1 = DIN EN 175301-803 A (DIN plug)
2 = M 12×1 circular plug (only for design with electrical connection in center)
Switching voltage, max
A = 250 V AC, 30 V DC

171
Pressure sensor

DSD
Pressure sensors

Description
Technical data
DSD sensors are single, mechanical-diaphragm pressure switches
They are used for pressure monitoring and are dependent upon the Function principle pressure switch
mechanical design of resulting pressure and preloaded spring force Lubricant oil and fluid grease NLGI 000, 00, 0
Operating temperature -30 to +100 °C; -22 to +212 °F
of the pressure spring Under pressure, a pressure plunger carries Operating pressure static:
the contact washer and moves it to the opposing contact and closes max 300 bar; max. 4 350 psi
dynamic:
the electrical circuit If the pressure is reduced by the amount of hys- max 150 bar; max. 2 175 psi
teresis, the switch opens again On an NC contact, contacts are made Switching pressure 0,5 to 45 bar; 7.25 to 653 psi
in the opposite way In single-line systems, it can be integrated into Switch type mechanical diaphragm pressure
switch
metering devices at the end of the lubrication line Contact type NO, NC (change-over with
rectangular plug connector only)
Features and benefits Contact rating max 18 VA, 90 VA, 100 VA
Switching voltage/current 36 V DC / 2 5 A / 0,5 A
• Available for a pressure rating from 0 to 45 bar 250 V AC / 5 A
in fixed increments Electrical connection M 3 or M 12 × 1 or
DIN EN 175301-803-A
• Electrical connection is established via screwed contacts, tab Pressure port M 10 × 1 taper
connectors, circular connectors or rectangular plug connectors
• Pressure monitoring, dependent upon the mechanical design of Materials:
Housing steel, galvanized, Cr6-free
resulting pressure and preloaded spring force of the Contact silver plated
pressure spring Membrane NBR
• Mechanical switch can be used as both a normally closed Protection class IP 65
Dimensions depending on model, ø × h
contact (NC) and a normally open contact (NO) 27,7 × 50 mm; 1.09 × 1.97 in
31,2 × 85 mm; 1.23 × 3.35 in
Applications Mounting position any

• Machine tools, printing machines, vehicles

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1701-EN
3D
skf-lubrication partcommunity com/3d-cad-models

172
Pressure sensor

DSD

Pressure sensors
Identification code D S D - A N – A 1

Product series DS

Pressure switch type D

Manufacturer marking
1 = marking 1 (only with electrical connection 1)
3 = marking 3 (only with electrical connection 2–4)
Type A

Rated switching pressure


0005 = 0,5 bar, 7 psi
0020 = 2 bar, 29 psi
0030 = 3 bar, 44 psi
0080 = 8 bar, 116 psi
0120 = 12 bar, 174 psi
0200 = 20 bar, 290 psi
0280 = 28 bar, 405 psi
0450 = 45 bar, 653 psi
N = Membrane material NBR

Type of contact
NC = closed (only with electrical connection 1–3 available)
NO = open (only with electrical connection 1–3 available)
CO = change-over (only with electrical connection 4 available)
Contact material
A = silver contacts
Pipe thread
1 = M 10×1 taper
Electrical connection
1 = screwed contacts M 3
2 = tab connector 6,3×0,8/screwed contacts M 3
3 = circular connector M 12×1
4 = rectangular plug connector DIN EN 175301-803-A (only as change-over (CO) available)

173
Pressure sensor

DSB1
Pressure sensors

Description
Technical data
SKF pressure switches of product series DSB are mechanical
piston pressure switches that are specially designed for use with Function principle pressure switch
NLGI 1-2 greases The location of the actuating piston inside the Lubricant grease NLGI 1, 2
Operating temperature –25 to +80 °C; –13 to +176 °F
pressure switch housing helps to ensure a continuous exchange of Operating pressure max 300 bar; 4 350 psi
grease around the measuring point (pressurization point between Operating voltage max 30 V AC; max 36 V DC
Operating current max 50 mA, min 1 mA
grease and actuating piston) This reliably prevents the same grease Breaking capacity max 1,2 VA
from being pressurized repeatedly, which could cause grease bleed- Mechanical service life 105 switching cycles
ing (separation of the soap skeleton of the grease from the stored Pressure port G 1/4 (F)
Electrical connection connector socket 3+PE:
oil) Pressure switches of product series DSB are designed for DIN EN 175 301-803 A
corrosivity category C3 or C5M per ISO 12944 cable:
ø 4 5 to 7 mm; ø 0.177 to 0.275 in
Switch type micro switch
Features and benefits Contact type change-over
Switching pressure range 20 to 300 bar; 290 to 4 350 psi;
• Adaptable to VR lubricant metering devices due to same increasing and decreasing
hole pattern, wall distance and connections Materials:
• Micro switch is designed as a change-over switch; can be Housing aluminum, anodized
Contact silver alloy, hard gold plating
used as both a normally closed contact (NC) and a normally Protection class IP 65; DIN EN 60529
open contact (NO) Dimensions depending on model
• Available for rising and falling pressures from min 60 × 105 × 76 mm;
max 150 × 153 × 76 mm;
20 to 300 bar in 10-bar increments min. 2.36 × 4.13 × 2.99 in
• No grease bleeding at measuring point max. 5.90 × 6.02 × 2.99 in
Mounting position any
Pressure switch permits continuous lubricant flow
Certification Germanischer Lloyd (GL)
without dead space
• Suitable for use with unstable greases with a tendency
to separate into soap and oil under high pressure
NOTE
Applications Further technical information, technical drawings,
• Machine tools accessories, spare parts or product function descriptions
• Printing machines available on SKF com/lubrication:
• Wind 1-1701-EN
• Vehicle 3D
• Steel and heavy industries
skf-lubrication partcommunity com/3d-cad-models

174
Pressure sensor

DSB1

Pressure sensors
Identification code D S B 1 - – 1 – 0 1

Product series DS

Pressure switch type B

Pressure switch I
S = switch on increasing pressure
F = switch on decreasing pressure
Rated switching pressure I
02 = 20 bar; 290 psi
03 = 30 bar; 435 psi
04 = 40 bar; 580 psi
(in 10-bar increments up to)
30 = 300 bar; 4 350 psi
Pressure switch II
0 = no pressure switch
S = switch on increasing pressure
F = switch on decreasing pressure
Rated switching pressure II
00 = no pressure switch
02 = 20 bar; 290 psi
03 = 30 bar; 435 psi
04 = 40 bar; 580 psi
(in 10-bar increments up to)
30 = 300 bar; 4 350 psi
Measurement connector
A = measurement connector for pressure gauge M 16×2
G = with pressure gauge 250 bar; 3 625 psi
H = with pressure gauge 400 bar; 5 800 psi
X = no measurement connector
Electrical connection
1 = DIN EN 175301-803 A (DIN plug)
Design
A = standard, based on corrosivity category C3 per ISO 12944, certified by Germanischer Lloyd
B = based on corrosivity category C5M per ISO 12944, certified by Germanischer Lloyd, suitable for offshore applications
Design key
01 = basic design (with thread G 1/4)

175
Pressure sensor

69630
Pressure sensors

Description
Technical data
Pressure switch 69630 senses supply line pressure when pressure
Order number 69630
is rising or falling One single contact signals system operation to
controller or system alarm Function principle pressure switch
Operating temperature –25 to +65 °C
–13 to +150 °F
Features and benefits Switching capacity 125, 250 or 480 V AC: 10 A
6 V DC: 15 A
• Simple pressure switch 24 V DC: 5A
250 V DC: 0,3 A
• Adjustable pressure ranges for decreasing and Operating pressure:
decreasing max 190 bar
increasing pressures to match system requirements max. 2 775 psi
• Use as single pressure switch or in a system with increasing max 207 bar
max. 3 000 psi
controller and solenoid valve Pressure port 1/4 NPTF (F)
Electrical connection 27/32 in hole for 1/2 in; conduit connector
Protection class housing and UL-listed switching
Applications elements: NEMA 3
Dimensions 57 × 146 mm
• Paper converting 2.25 × 5.75 in
Mounting position vertical
• Plastic processing
• Printing
• Packaging
• Metalworking
• Material handling equipment

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
442832
3D
skf-lubrication partcommunity com/3d-cad-models

176
Pressure sensor

234-10825-8

Pressure sensors
Description
Technical data
This pressure switch reliably monitors pressure in single-line lubri-
Order number 234-10825-8
cation systems at a pre-adjusted pressure value When adjusted
value is reached, pressure switch opens or closes an electric circuit Function principle rotatable pressure switch
via a defined piston stroke (depending on pressure power and pre- Lubricant oil and fluid grease NLGI 000, 00
Operating temperature –25 to +85 °C
load spring) A micro switch can be used for DC or AC voltage The –40 to +185 °F
switch's housing can be pivoted up to 360° The pre-adjusted Operating pressure max. 400 bar
switching point pressure value is set at the factory max. 5 800 psi
Switching pressure 100 to 400 bar
1 450 to 5 800 psi
Adjustability under pressure
Features and benefits Operating voltage adjustable:
30 to 250 V DC; 125; 250 V AC
• Simple, mechanically operated pressure switch Load resistance 0,25-5 A
Load inductive 0,25-5 A
• Designed as a change-over pressure switch Switch type micro switch with spring-loaded piston
Contact type change-over
• Monitors a pre-adjusted pressure value Contact electrical plug connector DIN72585
• Suitable for DC and AC voltage ø 2,5 mm
Material:
• Pivotable housing up to 360° Housing zinc-coated steel, UR
Contact electrical electroplated silver gilt
• Maintenance free Protection class IP 67, IP 6K9K
Dimensions 30 × 74 mm; 1.18 × 2.91 in
Mounting position any, but preferably vertical
Applications
• Machine tools
• Construction machinery
• Wind energy
NOTE
• Vehicle
Further technical information, technical drawings,
• Steel and heavy industries accessories, spare parts or product function descriptions
available on SKF com/lubrication

177
Pressure sensor

DSC2
Pressure sensors

Description
Technical data
DSC2 sensors are electronic pressure switches with an integrated
digital display for relative pressure measurement They are used pri- Order number DSC2–A100E–2A2B
marily for pressure monitoring Depending on the design, they also Function principle pressure switch
can assume control functions Pressure switch points, pressure indi- Lubricant oil and fluid grease NLGI: 000–0
Operating temperature –10 to +80 °C
cation and the switching logic can be configured and programmed
+14 to 176 °F
easily The four-digit, digital display that indicates switching with Operating pressure max 300 bar
LEDs DSC2 can operate in switching point, hysteresis and window max. 4 350 psi
Switch type micro switch
function modes The switching mode can be programmed separately Contact type change-over
for each output Operating voltage 18 to 30 V DC
Power consumption max 35 mA
Output signal 2, PNP/NPN
Features and benefits Vibration resistance 20 g (10–2 000 Hz)
Service life 100 × 106 pressure changes
• Available for rising and falling pressures
Material:
from 0 to 100 bar in 0 5-bar increments Housing aluminum, stainless steel
• Micro switch is designed as a change-over switch; can be Control panel polyester film
Electrical connection M 12 × 1, 4-pin
used as both a normally closed contact (NC) and a normally Pressure port G 1/4 (F)
open contact (NO) Protection class IP 67
Dimensions 34 × 90,7 × 49,4 mm
• Four-digit, digital display indicates switching with LEDs 1.33 × 3.57 × 37.4 in
• Can operate in switching point, hysteresis and window Mounting position any
function modes
• Diagnostic output based on the DESINA specification
• UL certification

Applications NOTE
Further technical information, technical drawings,
• Machine tools
accessories, spare parts or product function descriptions
• Printing machines available on SKF com/lubrication:
• Wind 1-1701-EN
• Vehicle 3D
• Steel and heavy industries skf-lubrication partcommunity com/3d-cad-models

178
Pressure sensor

DSC3

Pressure sensors
Description
Technical data
DSC3 sensors are electronic pressure switches with an integrated
digital display for relative pressure measurement They are used pri- Order number DSC3–A100K–3A2B
marily for pressure monitoring Depending on the design, they also
Function principle pressure switch
can assume control functions Pressure switch points, pressure indi- Lubricant oil and fluid grease NLGI: 000–0
cation and the switching logic can be configured and programmed Operating temperature –25 to +80 °C
–13 to 176 °F
easily The display is a pivoted, four-digit, digital display DSC3 can be Operating pressure max. 300 bar
integrated into lubrication line It operates in switching point, hyster- max. 4 350 psi
esis, and window function modes The switching mode can be pro- Switch type micro switch
Contact type change-over
grammed separately for each output Operating voltage 9 to 35 V DC
Power consumption max. 35 mA
Output signal 2, PNP transitor stages
Features and benefits Vibration resistance 20 g (5–500 Hz)
• Available for rising and falling pressures Service life 100 × 106 pressure changes
from 0 to 100 bar in 0 5-bar increments Material:
• Micro switch is designed as a change-over switch; can be used as Housing plastic
both a normally closed contact (NC) and a normally open Electrical connection M 12 × 1, 4-pin
Pressure port via t connector, 2 × G 1/8 (F)
contact (NO) Protection class IP 67
• Easy to install into a lubrication line Dimensions 42 × 115 × 40 mm
• Pivoted, four-digit, digital display 1.65 × 4.53 × 1.57 in
Mounting position any
• Can operate in switching point, hysteresis
and window function modes
• Programmming lock to protect against unauthorized
adjustment of drive
• Switching displayed using LEDs

Applications NOTE
• Machine tools Further technical information, technical drawings,
• Printing machines accessories, spare parts or product function descriptions
• Wind available on SKF com/lubrication:
• Vehicle 1-1701-EN
• Steel and heavy industries 3D
skf-lubrication partcommunity com/3d-cad-models

179
Pressure sensor

234-11145-3, -4, -5, -9


Pressure sensors

Description
Technical data
These maintenance-free electronic pressure sensors are suitable for
Function principle digital pressure switch
pressure measurements for gases and fluids They are user friendly Lubricant oil and fluid grease NLGI 000–00,
and can be applied easily in standard or superior applications The grease NLGI 1 ,2
space-saving housing is pivotable up to 320° for optimal readability Operating temperature –25 to +125 °C; –134 to +185 °F
Operating pressure max 600 bar; max. 8 700 psi
of the 4-digit, digital display One or two switching outputs and an 234-11145-5:
analog output signal for switching point and hysteresis Both can be max 400 bar; max. 5 800 psi
adjusted via push buttons Different value units such as bar, mbar, Operating voltage 18–36 V DC
Operating current max 500 mA
psi or MPa can be selected Current draw ≤ 50 mA
Output signal 1 or 2 × PNP; 1 analog, digital,
NO or NC adjustable
Features and benefits Switching frequency max 200 Hz
Switching point adjusted 234-1145-5: 175 bar; 2 465 psi
• Menu-guided adjustments via 2 push buttons
Material:
• Pre-adjustable hysteresis Housing PA6 6, stainless steel, FKM
• Programmable parameters, password protected Measuring cell ceramics AI203
• Reverse polarity protection of the supply voltage, excess voltage, Apapter stainless steel
Electrical connection M 12 × 1; 4 pin plug
override and short circuit protection are provided Pressure port G 1/4 or G 3/8; DIN3852
• Compact housing with 320° pivot Protection class IP 67; EC 60529
• For standard and superior applications Dimensions min 34 × 94 × 49 mm
max 34 × 134,5 × 49 mm
min. 1.34 × 3.7 × 1.9 in
Applications max. 1.34 × 5.3 × 1.9 in
Mounting position any
• Marine, off-shore applications
• Wind, vehicle, steel and heavy industries

Order information NOTE


Order number Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
234-11145-3 1 × PNP, 4-20 MA, with adapter G 1/4 and connector available on SKF com/lubrication
234-11145-4 1 × PNP, 4-20 MA, basic model
234-11145-5 2 × PNP, 0-20 MA, with adapter G 1/4 and connector,
front flushed
234-11145-9 1 × PNP, 4-20 MA, with adapter G3/8 and connector

180
Pressure sensor

234-10330-4

Pressure sensors
Description
Technical data
This electronic pressure switch has a 4-digit, digital display, two
Order number 234-10330-4
switching outputs and an analog output signal for switching point
and hysteresis Both can be adjusted via push buttons The water- Function principle digital pressure switch
proofed housing is pivotable up to 290° for optimal readability of Lubricant oil, fluid grease NLGI 00, 000, 0, grease
NLGI 1 ,2
digital display The pressure switch is virtually maintenance free Operating temperature –20 to +85 °C ; –4 to +185 °F
Operating pressure max 1 000 bar; max. 14 500 psi
Analog output signal 0/4–20 mA,
Features and benefits apparent ohmic resistance ≤ 500 Ω
Operating voltage 15–30 V DC, nominal 24 V DC
• Menu-guided adjustments via 3 push buttons indicating Signal output type PNP-Transistor
Switching current max 0,7 A
status of outputs Current consumption < 100 mA
• Peak value storage Switching cycle ≥ 20 Mio
Electrical connection M12 × 1; 5 pin
• Adjustable hysteresis and absorption Pressure port G 1/4 (BSPP)

• Programmable parameters Material:


Housing stainless steel 1 4404, NBR
• Password protected Control panel zinc die casting, surface treated
Protection class IP 67
• Reverse polarity and overvoltage protected; short-circuit proof Dimensions 39,5 × 105,5 × 46,3 mm
1.55 × 4.15 × 1.82 in
Mounting position any
Applications
• Machine tools
• Printing machines
• Wind
• Vehicles
NOTE
• Steel and heavy industries Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

181
Pressure sensor

234-13161-...
Pressure sensors

Description
Technical data
This compact, maintenance-free electronic pressure switch has a
Function principle digital pressure switch
3-digit, digital display, one switching output and an analog output Lubricant oil and fluid grease NLGI 0–000,
signal for switching point and hysteresis Both can be adjusted via grease NLGI 1 ,2
push buttons For optimum adaptation to a particular application, Operating temperature –25 to +80 °C; –13 to +175 °F
Operating pressure 234-13161-5:
the instrument has many additional adjustment parameters, e g max 600 bar; max. 8 700 psi
switching delay times, NO and NC function of the outputs 234-13161-9:
max 250 bar; max. 3 625 psi
Operating voltage 20–32 V DC
Features and benefits Current consumption approx 100 mA
(without switching outlet)
Electrical connection plug DIN 43650 (3pin+ PE) or
• Integrated pressure sensor with thin-film strain
plug 4-pin binder 714, M 18 × 1
gauge on stainless steel membrane Protection class IP 65
• 3-digit, digital display Dimensions 35 × 119 × 48 mm
1.37 × 4.68 × 1.89 in
• Independently adjustable switch-back hysteresis Mounting position any
and switching point
• Reverse polarity protection of the supply voltage, excess
voltage, override and short-circuit protection are provided
• Password protected
• Directly installable via G 1/4 adapter into pressure line

Applications
• Marine off-shore applications
• Wind, vehicles, steel and heavy industries

Order information NOTE


Order number Designation
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
234-13161-5 1 × PNP, 4-20 MA, G 1/4, with digital display, available on SKF com/lubrication
operating pressure max 600 bar; max. 8 700 psi

234-13161-9 1 × PNP, 4-20 MA, G 1/4, with digital display,


operating pressure max 250 bar; max. 3 625 psi

182
Pressure sensor

234-11272-4

Pressure sensors
Description
Technical data
The electronic pressure switch with internal stainless steel
Order number 234-11272-4
diaphragm, suits for pressure control in automatic single-line lubri-
cation systems It has a 4 digit 7 segment digital display, two solid Function principal electrically operated dual digital
state contacts or two solid state contacts plus one analog output for pressure switch
Lubricant oil and fluid grease NLGI 00, 000, 0
switching point and hysteresis All contacts can be adjusted via push grease NLGI 1, 2
buttons The pressure switch is virtually maintenance free Operating temperature –25 to +100 °C ; –13 to +212 °F
Operating pressure 10 to 600 bar; 145 to 8702 psi
Operating elements 3 easy-response push buttons
Features and benefits Protection class IP 65 with plug
Pressure port G 1/4 M
Electrical connection M12 × 1; for 4 pin or 5 pin plug
• Alphanumeric 4-digit 7 segment LED display
Current output 4-20 mA, apparent ohmic
• Microprocessor controlled resistance 600 Ω at 24 V DC
Power supply 18-32 V DC reversed
• Self monitoring with error display polarity protected (SELV, PELV)
Digital display 4-digit 7 segment LED display
• Scalable analog output Power consumption approx 50 mA at 24 V DC
without load
• Programmable parameters via keypad Material:
Wetted parts stainless steel 1 4301
• Adjustable password protection Electronics housing aluminum die-cast
• Revers polarity and overvoltage protected, short-circuit proof Seals FKM
Dimensions 75 × 130 × 55 mm
max 60 VDC temporary 2.95 × 5.12 × 2.16 in
Mounting position vertical
• Rugged stainless steel construction
• Vibration and shock-proof, longterm stability

Applications
NOTE
• Machine tools
Further technical information, technical drawings,
• Chemical technics accessories, spare parts or product function descriptions
• Wind, vehicle, steel and heavy industries available on SKF com/lubrication
• Automation

183
Pressure sensor

DSC1
Pressure sensors

Description
Technical data
DSC1 pressure switches are electronic pressure switches with inte-
grated digital display for relative pressure measurement They are Order number DSC1–A040A–1A2A
used primarily for pressure monitoring Depending on the design,
Function principle pressure switch
they also can assume control functions Pressure switch points, pres- Lubricant oil and fluid grease NLGI 000, 00, 0
sure indication, and the switching logic can be configured and pro- Operating temperature –10 to +80 °C
+14 to +176 °F
grammed easily A backlit, four-digit, digital display indicates switch- Operating pressure max 100 bar
ing with LEDs DSC1 can operate in switching point, hysteresis and max. 1 450 psi
window function modes The switching mode can be programmed Switch type micro switch
Contact type change-over
separately for each output Operating voltage 10 to 32 V DC
Power consumption max 50 mA
Output signal 2, PNP transistor stages
Features and benefits Vibration resistance 10 g (5-500 Hz)
• Available for rising and falling pressures from Service life 100 × 106 pressure changes
0 to 40 bar in 0 2-bar increments Material:
• Micro switch is designed as a change-over switch, Housing aluminum, stainless steel
can be used as both a normally closed contact (NC) Control panel polycarbonate
Electrical connection M 12 × 1, 5-pin
and a normally open contact (NO) Pressure port G 1/8 (F)
• Backlit, four-digit digital display indicates switching Protection class IP 65
with LEDs on a backlit Dimensions 34 × 90,7 × 49,4 mm
1.33 × 3.57 × 37.4 in
• Can operate in switching point, hysteresis and Mounting position any
window function modes
• Encodable access protection
• Digital and analog output

Applications
• Machine tools NOTE
• Printing machines Further technical information, technical drawings,
• Wind accessories, spare parts or product function descriptions
• Vehicle available on SKF com/lubrication:
• Steel and heavy industries 1-1701-EN

184
Pressure sensor

247333

Pressure sensors
Description
Technical data
The 24733 analog pressure transducer signals actual system
pressure to a monitoring controller It can be installed in end of sin- Order number 247333
gle-line metering device manifolds or by the use of adapters Comes
Function principal analog pressure transducer
with 1,8 m (72 in), shielded, shielded 24-gauge connecting wire Lubricant oil and fluid grease;
Maximum length of wire between transducer and monitor NLGI 000, 00, 0;
grease: NLGI 1, 2
is 9,1 m (30 ft) Switching pressure range 0 to 275 bar
0 to 4 000 psi
Accuracy ±1%
Features and benefits Operating pressure max 515 bar
max. 7 500 psi
• Analog pressure transducer signals actual system pressure Operating temperature –29 to +82 °C
from 0 bar to 276 bar (0 to 4 000 psi) –20 to +180 °F
Electrical input 10 to 30 V DC
• Complete unit with 1,8 m (72 in), shielded, Voltage output 1-6 V DC
24-gauge connecting wire Offset 1 V DC
Enclosure NEMA 4X Rating
• Installable on end of single-line metering
Pressure port 1/4 NPT (m)
device manifolds or by the use of adapters Electrical connection 24 AWG 360° PVC shielded UL approved
• Sturdy, easy-to-handle product Materials stainless steel
Dimensions 16 × 76,2 mm;
• Cost-saving alternative to high-end sensors 0.625 × 3 in
Mounting position any
Applications
• Metalworking
• Material handling equipment
• Off-road applications
• Mobile equipment use
• Food and beverage
NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication

185
Flow monitors and sensors

186
Overview of flow monitors and sensors

Flow monitors and sensors


Digital flow sensors with digital output signal

Product Lubricant Function type Operating temperature Voltage Page


oil/fluid
grease grease

°C °F V DC V AC

GS204P • – Digital oil flow sensor +10 to +50 +50 to +122 24 – 188

Hose connection monitor

Product Lubricant Function type Operating temperature Voltage Page


oil/fluid
grease grease

°C °F V DC V AC

HCC • • Monitoring device for hose -50 to +70 -58 to +158 12 / 24 – 189
connections

187
Flow sensor
Flow monitors and sensors

GS304P

Description
Technical data
Flow sensors keep an eye on the flow of oil from a metering point
to the lubrication point, metering out a small amount of oil for only a Order number GS304P
short period of time They are suitable for intermittent, centralized
Function principle flow sensor
lubrication systems e g with piston metering devices, metering Measuring principle calorimetrical
elements, injection oilers, oil and air centralized lubrication systems Lubricant 1 ) oil (10 to 2 000 mm2/s)
Metering quantity 0,01 - 0,6 cm 3/pulse
0.0006 - 0.03 in 3/pulse
Clock frequency 2) max 4 pulse/min
Features and benefits Operating temperature +10 to +50 °C, +50 to +122 °F
Operating pressure max 40 bar; 580 psi
• Provide simple control Rated voltage 24 V DC
Residual ripple 10%
• Monitor flow of lubricant from the metering point Working range UA 18 to 30 V DC
to the lubrication point Max power consumption IE 25 mA
Pulse output 3s
• Meter out a small amount of oil for only Load current IA for GS300 max 10 mA
a short period of time for GS304 max 500 mA per output
Output protection short-circuit protection
Built-in plug circular connector with
M12×1 screw plug
Applications Fluid connection M 8x1 mm, port tapped for
solderless Ø 4 mm tube
• Machine tools connection
• Automotive manufacturing Dimensions 95 × 50 × 20 mm
3.74 × 1.96 × 0.78 in
• Industrial assembly and automation Mounting position directly upstream of lubrication point
Vibration resistance 20 g
(DIN / IEC 68-2-27, 10-2000 Hz)
Impact resistance 50 g
(DIN / IEC 68-2-27, 11 ms)

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1704-EN
3D
1) Sensor needs 30 sec of warm-up time
skf-lubrication partcommunity com/3d-cad-models 2) The use of oils containing corrosive and/or abrasive additives may impair
sensor function and possibly damage the sensor

188
Hose connection control unit

Flow monitors and sensors


HCC

Description
Technical data
The hose connection control (HCC) is intended to monitor
electrically conductive, high-pressure lubrication hoses for line Function principle control and monitoring device for
breakage If there is a fault in the main line or feed lines, the unit hose connections
Operating temperature Isolator:
alerts the machine operator immediately Operation of the HCC is not –50 to +70 °C; –58 to +158 °F
affected by line lengths, ambient temperature, pressure differential Controller:
–25 to +70 °C; –13 to +158 °F
or pressure losses Utilizing non-conductive lubricants or hydraulic Controller storage:
fluids, this monitoring system has an operating pressure of up to –40 to +70 °C; –40 to +158 °F
300 bar (4 350 psi) and can be used in temperatures ranging Power supply 12/24 V DC
Monitored hose per
from –40 to +70 °C (–40 to +158 °F) monitoring unit max 15 pieces at 12 V DC
max 24 pieces at 24 V DC
Features and benefits Positive ok signal 12/24 V PNP
Signal cable to
• Immediately detects hose ruptures one cut-off connector 20 m; 65 ft
• Expandable at any time Signal cable at cut-off approx 150 mm; 5.90 in
• Easy retrofit in existing lubrication systems Protection class IP 65
Dimensions 100 × 85 × 40 mm
• Monitors difficult-to-access hoses to lubrication points 3.93 × 3.34 × 1.57 in

• Common LED signal of all connected hoses on the display

Applications
Order information
• Construction and mining machines; cranes, forklifts
• Wood-handling and agriculture machine Order number Designation

236-10986-1 HCC, evaluation unit

NOTE 236-10153-3 HCC, with cable 20 m


Further technical information, technical drawings, 532-34839-2 HCC, endlink HCC DN 8-10L-E
accessories, spare parts or product function descriptions
available on SKF com/lubrication: 532-37731-1 basic kit consisting of above three parts
16966 EN, 951-170-232 532-34839-6 HCC, endlink HCC DN 4-6L-E
3D
532-34839-3 HCC, interlink HCC DN 8-10L-I
skf-lubrication partcommunity com/3d-cad-models
532-34839-5 HCC, Interlink HCC DN 4-6L-I

189
valves

190
Overview of solenoid valves

Solenoid valves

Product Type Operating pressure Operating temperature Voltage Page


max.

bar psi °C °F V DC V AC

Valves
350241 3-way 10,3 150 -18 to +60 0 to 140 – 110–240 192
350242 3-way 10,3 150 -18 to +60 0 to 140 – 110–240 192
350244 4-way 10,3 150 -18 to +49 0 to 120 – 110–240 192
350245 4-way 10,3 150 -18 to +49 0 to 120 – 110–240 192

350282 3-way 10,3 150 -18 to +60 0 to 140 12 – 193


350283 3-way 10,3 150 -18 to +60 0 to 140 24 – 193

253-14076-6 3/2-way 0,5–16 7.3–232 -10 to +55 14 to 131 – 110 194


253-14076-7 3/2-way 0,5–16 7.3–232 -10 to +55 14 to 131 – 230 194

525-32085-1 3/2-way 0–400 0–5 800 -20 to +60 -4 to +140 24 – 195


525-32086-1 3/2-way 0–400 0–5 800 -20 to +60 -4 to +140 – 110 195
525-32087-1 3/2-way 0–400 0–5 800 -20 to +60 -4 to +140 – 230 195

161-110-031 2/2-way max 500 max. 7 250 -25 to +80 -13 to +176 24 – 196
161-140-050 4/2-way max 320 max. 4 350 -25 to +80 -13 to +176 24 220 197

191
Solenoid valve

35024 ...
Valves

Description
Technical data
Electric solenoid-operated air valves 350241 to 350245 operate
Function principle
as 3-way or 4-way solenoid air valves They are used to operate Model 350241, 350242 3-way, solenoid-operated air valve
single-stroke or reciprocating-stroke, air-controlled pumps in Model 350244, 350245 4-way, solenoid-operated air valve
single-line systems Timer- and pressure-controlled air is supplied
Operating temperature
to the pumps, activating air-powered forward strokes and spring- Model 350241, 350242 –18 to +60 °C, 0 to +140 °F
(3-way) or air-powered (4-way) return strokes In doing so, pumps Model 350244, 350245 –18 to +49 °C, 0 to +120 °F
discharge lubricant to the connected metering devices Operating pressure max 10 bar; 150 psi
Operating voltage 110–240 V AC
Current 8,4 A
Features and benefits Current inrush
Model 350241, 350244 0,11 A
• Timer- and pressure-controlled pump operation Model 350242, 350245 0,055 A
• Use as 3-way or 4-way solenoid valves Current holding
Model 350241, 350244 0,7 A
• For operation of single-stroke or reciprocating-stroke pumps Model 350242, 350245 0,35 A
• Flexible usage selectable on electrical V AC power requirements Air inlet/outlet 1/4 NPT (F)
Conduit connection 1/2 NPS (F)
Mounting position any
Applications
• Mining and mineral processing
• Heavy machines

Order information NOTE


Order number Designation Type
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication
350241 110 V AC, 50 Hz, 120 V AC, 60 Hz, 8,4 VA 3-way
350242 220 V AC, 50 Hz, 240 V AC, 60 Hz, 8,4 VA 3-way
350244 110 V AC, 50 Hz, 120 V AC, 60 Hz, 8,4 VA 4-way
350245 220 V AC, 50 Hz, 240 V AC, 60 Hz, 8 4 VA 4-way

192
Solenoid valve

350282, 350283

Valves
Description
Technical data
Electric solenoid-operated air valves 350282 and 350283 operate
Order number 350282
as DC 3-way solenoid air valves They are used to operate sin- 350283
gle-stroke, air-controlled pumps in single-line systems Timer- and
pressure-controlled air is supplied to the pumps, activating air-pow- Function principle 3-way solenoid air valve
ered forward strokes and spring- (3-way) return strokes In doing so, Voltage supply:
pumps discharge lubricant to the connected metering devices Model 350282 12 V DC, 6 VA
Model 350283 24V DC, 6 VA
Operating temperature –18 to +60 °C, 0 to +140 °F
Features and benefits Operating pressure max 10 bar; 150 psi
Air inlet/outlet 1/8 NPT (F)
Cv factor 0 18
• Timer- and pressure-controlled pump operation Mounting position any
• Use as 3-way solenoid valves
• For operation of single-stroke pumps
• Flexible usage selectable on electrical 12 or
24 V DC power requirements

Applications
• Mining and mineral processing
• Heavy machines

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
442832

193
Solenoid valve

253-14076-X
Valves

Description
Technical data
Pumps in single-line systems can be supplied and actuated with
compressed air via servo-controlled, 3/2-way piston valves (mag- Function principle 3/2-way solenoid air valve with
netic valve) For function and operation of the valve, a minimum dif- servo piston
Initial state outlet A open
ferential pressure of 0,5 bar is requested The valve is equipped with Operating temperature –10 to +55 °C
a control for initiation and check of function Currentless, the valve is +14 to +131 °F
Operating pressure 0,5–16 bar;
open to outlet A It has a smooth-running servo piston A 3/2-way 7.3–232 psi
pilot valve (tilting armature valve) provides safe and reliable Supply voltage
operation Model 253-14076-6 110 V AC, 50 Hz
Model 253-14076-7 230 V AC, 50-60 Hz
Power consumption 8W
Features and benefits Protection class IP 65
Air inlet G 1/2
• Simple to install; no extra parts required Air return connection G 3/4
• Service friendly manual control of function Nominal width 12 mm; 8.35 in, socket
Materials brass, NBR
• Medium, separated pilot valve for higher operational safety Output connection socket for cable ø 7 mm
• Ground-optimized piston design for low switching pressure ø 0.28 in
• Power-saving pulse inductor Dimensions 179,5 × 76 × 33 mm
7.06 × 3 × 1.3 in
Mounting position any, especially impulse upward
Applications
• Conveyors, transportation systems
• Chain lubrication
• Spray systems

Order information NOTE


Order Type Operating Connection
Further technical information, technical drawings,
number voltage thread BSPP (F) accessories, spare parts or product function descriptions
available on SKF com/lubrication:
W-115-EN-1212
253-14076-6 3/2-way valve 110-120 V AC G 1/2

253-14076-7 3/2-way valve 230 V AC G 1/2

194
Solenoid valve

525-320 ...-1

Valves
Description
Technical data
3/2-way solenoid valves are suitable to supply lubricant in different
lubrication circuits and also are used as release valves Each lubrica- Function principle 3/2-way solenoid valve
tion circuit can be connected to one pump outlet by switching off or Initial state outlet B to R is open
Lubricant oil, fluid grease and grease NLGI 0, 1, 2
switching on separately Thereby, the pressure inlet is connected Operating temperature –20 to +60 °C
either to one or to the other circuit Solenoid valves are equipped –4 to +140 °F
Operating pressure 0–400 bar;
with a dry magnetic rotor and a conical seat valve In their initial 0–5 800 psi
state, the valves always are open to the return line and are activated Flow rate max 2 400 cm3/min
by a return spring The current switching positions remain as long as max. 146.5 in3/min
Supply voltage 24 V DC, 110 V AC, 50 Hz
current is switched on Solenoid valves are switchable and resistant 230 V AC, 50-60 Hz
to compression in both flow directions Current draw 0,83 A; 0,2 A; 0,1 A
Rated power 20 W
Pressure connection G 3/8
Features and benefits Protection class IP 54
Isolation class F
• Suitable to divide lubricant in different lubrication circuits Materials steel, aluminum
on different time sequences Dimensions 147 × 50 × 45 mm
• Equipped with a dry magnetic rotor and a conical seat valve 5.78 × 1.96 × 1.77 in
Mounting position any
• Switchable and resistant to compression in both flow directions

Applications
• Construction machinery
• Wind turbines
• Mining

Order information NOTE


Order Type Operating Connection
Further technical information, technical drawings,
number voltage thread BSPP (F) accessories, spare parts or product function descriptions
available on SKF com/lubrication:
W-115-EN-1212
525-32085-1 3/2-way valve 24 V DC G 3/8
525-32086-1 3/2-way valve 110 V AC G 3/8
525-32087-1 3/2-way valve 230 V AC G 3/8

195
Solenoid valve

161-110-031
Valves

Description
Technical data
The directional valves are used to control the flow of lubricants,
e g to divide up a central lubrication system into a number of lubri- Order number 161-110-031
cation circuits (zoned actuation) or to switch between circulating and
Function principle 2/2-way solenoid valve
intermittently operated lubrication circuits Valves for a maximum Lubricant oil and grease up to NLGI 2
pressure of up to 45 bar can be used for single-line lubrication sys- Operating temperatures:
Oil, 4–1 500 mm/s2 –40 to +80 °C; –40 to +176°F
tems with metering devices Valves for a pressure range of up to 300 Grease, 700 mbar –25 to +80 °C; –13 to +176°F
or 500 bar also are suitable for progressive systems Operating pressure max 500 bar, max. 7 250 psi
Hydraulic connector G 1/4
Materials aluminum
Features and benefits Supply voltage 24 V DC
Rated current 0,67 A
• Directional valves for oil with a low or high effective viscosity and
Rated power 16 W, 5 W
greases up to NLGI Grade 2 Electrical connection DIN EN175301-803
• 2-, 4- or 5-way valve switching functions selectable Protection class IP 65 with plug
Dimensions 146,5 × 55 × 45 mm
for zoned actuations 5.77 × 2.17 × 1.77 in
• For single-line systems with sectional supplying of lubricants Mounting position any
dependent upon different times and quantities Dimensions 179,5 × 76 × 33 mm
7 06 × 3 × 1 3 in
• Manual action possible

Applications
• Paper industry
• Steel industry
• Heavy industry

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication: |
1-1703-EN

196
Solenoid valve

161-140-050

Valves
Description
Technical data
These directional valves are used to control the flow of lubricants,
e g to divide up a central lubrication system into a number of lubri- Order number 161-140-050
cation circuits (zoned actuation) or to switch between circulating and
Function principle 4/2-way valve
intermittently operated lubrication circuits Valves for a maximum Lubricant oil and grease up to NLGI 2
pressure of up to 45 bar can be used for single-line lubrication sys- Valve, basic position sliding, open P to A
Operating temperatures:
tems with metering devices Valves for a pressure range of up to 300 oil, 4-1 500 mm/s2 –40 to +80 °C; –40 to +176°F
or 500 bar also are suitable for progressive systems grease, 700 mbar –25 to +80 °C; –13 to +176°F
Operating pressure max 320 bar; max. 4 350 psi
Hydraulic connector base plate G 1/4
Features and benefits Materials aluminum
Supply voltage DC and AC
• Directional valves for oil with a low or high effective
Rated current 1,33 A at 24 V DC;
viscosity and greases up to NLGI Grade 2 0,17 A at 220 V AC, 50 Hz
• 2-, 4- or 5-way valve switching functions selectable Rated power 16 W, 5 W
Electrical connection DIN EN175301-803
for zoned actuations Protection class IP 65 with plug
• For single-line systems with sectional supplying of Dimensions 148 × 58 × 45 mm
lubricants dependent upon different times and quantities 5.83 × 2.28 × 1.77 in
Mounting position any
• Manual action possible

Applications
• Paper industry
• Steel industry
• Heavy industry

NOTE
Further technical information, technical drawings,
accessories, spare parts or product function descriptions
available on SKF com/lubrication:
1-1703-EN

197
Index

24-1074-2210 151 321-401G7 111 321-601T2 111


24-1074-2240 151 321-401T2 111 321-601T3 111
24-1074-2270 151 321-401W2 111 321-601W1 111
161-110-031 191 321-403G1 111 321-601W2 111
161-110-031 196 321-403G2 111 321-601W3 111
161-120-067+910 25 321-403G3 111 321-603G1 111
161-120-067+924 25 321-403G4 111 321-603G2 111
161-140-050 191 321-403G7 111 321-603G3 111
161-140-050 197 321-403G7-S8 111 321-603T1 111
169-400-405 25 321-403T1 111 321-603T2 111
179-990-486 165 321-403T2 111 321-603T3 111
234-10330-4 181 321-403T3 111 321-603W1 111
234-10825-8 177 321-403W1 111 321-603W2 111
234-11145-3 180 321-403W2 111 321-603W3 111
234-11145-4 180 321-403W3 111 321-606G1 111
234-11145-5 180 321-406G1 111 321-606G2 111
234-11145-9 180 321-406G2 111 321-606G3 111
234-11272-4 183 321-406G3 111 321-606T2 111
234-13161-5 182 321-406G4 111 321-606T3 111
234-13161-9 182 321-406G7 111 321-606W1 111
236-10153-3 189 321-406G7-S8 111 321-606W2 111
236-10567-5 163 321-406T1 111 321-606W3 111
236-10567-6 163 321-406T2 111 321-610G1 111
236-10850-7 165 321-406T3 111 321-610G2 111
236-10850-8 165 321-406W1 111 321-610G3 111
236-10850-9 165 321-406W2 111 321-610G7 111
236-10980-6 165 321-406W3 111 321-610T1 111
236-10986-1 189 321-410G1 111 321-610T2 111
236-11066-1 165 321-410G2 111 321-610T3 111
236-11335-8 167 321-410G3 111 321-610W1 111
237-11204-8 71 321-410G4 111 321-610W2 111
253-14076-6 191 321-410G7 111 321-610W3 111
253-14076-6 194 321-410G7-S8 111 321-616G7 111
253-14076-7 191 321-410T1 111 321-620G7 111
253-14076-7 194 321-410T2 111 321-630G7 111
321-101 111 321-410T3 111 341-453-K-S8 93
321-103 111 321-410W1 111 341-453-S8-VS 93
321-106 111 321-410W2 111 341-456-K-S8 93
321-401G1 111 321-410W3 111 341-456-S8-VS 93
321-401G2 111 321-601G1 111 341-460-K-S8 93
321-401G3 111 321-601G2 111 341-460-S8-VS 93

198
Index

341-466-K-S8 93 391-060-K 109 554-32814-1 137


341-466-S8-VS 93 391-060-K-S8 109 645-41062-3 73
341-853-K 93 391-100-K 109 645-41062-4 73
341-853-VS 93 391-100-K-S8 109 645-41062-7 73
341-856-K 93 391-150-K 109 645-41062-8 73
341-856-VS 93 391-150-K-S8 109 645-41062-9 73
341-860-K 93 406-004-VS 25 645-41064-2 73
341-860-VS 93 408-004-VS 25 645-41064-3 73
352-005-K 103 447-71899-1 117 645-41064-4 73
352-005-K-S8 103 447-71901-1 117 645-41064-6 73
352-005-S8-VS 103 447-71902-1 117 645-41064-7 73
352-005-VS 103 447-71903-1 117 645-41064-8 73
352-010-K 103 447-71904-1 117 645-41073-5 73
352-010-K-S8 103 447-71905-1 117 645-41110-2 73
352-010-K-S82 103 447-71906-1 117 645-41110-3 73
352-010-S8-VS 103 454-71505-1 137 645-41119-1 73
352-010-S82-VS 103 454-71506-1 137 645-41119-2 73
352-010-VS 103 454-71507-1 137 645-41175-5 73
352-020-K 103 454-71508-1 137 647-41151-2 117
352-020-K-S8 103 454-71509-1 137 647-41152-2 117
352-020-K-S82 103 466-421-001 25 647-41152-4 117
352-020-S8-VS 103 506-140-VS 25 647-41153-2 117
352-020-S82-VS 103 525-32083-1 87 647-41154-4 117
352-020-VS 103 525-32085-1 191 647-41154-5 117
352-030-K-S82 103 525-32085-1 195 647-41154-6 117
352-030-S82-VS 103 525-32086-1 191 647-41154-7 117
352-040-K 103 525-32086-1 195 647-41155-2 117
352-040-K-S8 103 525-32087-1 191 647-41156-2 117
352-040-S8-VS 103 525-32087-1 195 664-34135-6 162
352-040-VS 103 532-34839-2 189 664-34135-7 162
352-060-K 103 532-34839-3 189 898-210-001 99
352-060-K-S8 103 532-34839-5 189 995-901-061 25
352-060-S8-VS 103 532-34839-6 189 995-901-063 25
352-060-VS 103 532-37731-1 189 995-993-610 103
391-010-K-S1 109 547-33924-1 117 995-993-610-VS 103
391-020-K 109 547-33925-1 117 995-993-620 103
391-020-K-S1 109 547-33926-1 117 995-993-620-VS 103
391-020-K-S8 109 554-32810-1 137 995-993-630 103
391-030-K-S1 109 554-32811-1 137 995-993-630-VS 103
391-040-K 109 554-32812-1 137 995-993-660 103
391-040-K-S8 109 554-32813-1 137 995-994-003 93

199
Index

995-994-006 93 80076 81 82676 26


995-994-010 93 80077 81 82885 18
995-994-016 93 80078 81 82886 56
995-994-103 93 80079 81 83167 61
995-994-103-VS 93 80080 81 83309-1 129
995-994-106 93 80081 81 83309-2 129
995-994-106-VS 93 80083 81 83309-3 129
995-994-110 93 80084 81 83309-4 129
995-994-110-VS 93 80085 81 83309-5 129
995-994-116 93 80086 81 83309-6 129
995-994-116-VS 93 80087 81 83313 119
997-000-185 150 80088 81 83314 129
1810 53 80089 81 83314-9 129
1812 14 80090 81 83336HV-1 134
1826 30 80091 81 83336HV-2 134
3515-07-2022 165 80105 81 83336HV-3 134
3515-07-6120 165 80106 81 83336HV-4 134
3515-10-2021 165 80107 81 83336HV-5 134
3515-10-6020 165 80108 81 83336HV-6 134
3515-10-6120 165 80109 81 83336HV-7 134
3515-10-6320 165 80110 81 83336HV-8 134
3515-10-6620 165 80111 81 83336HV-9 134
3515-10-7620 165 80112 81 83336HV-10 134
11962 123 80120 81 83337HV 134
11962 125 80121 81 83338HV 134
11963 123 80122 81 83535 119
11963 125 80127 35 83599 62
11964 123 80128 35 83660 121
11964 125 80134 81 83662 121
11965 123 80135 81 83667 18
11965 125 81770-1 135 83668 56
12658 123 81770-2 135 83715-1 129
12658 125 81770-3 135 83715-2 129
14253 119 81770-4 135 83715-3 129
14312 119 81770-5 135 83715-4 129
14361 119 81770-6 135 83715-6 129
69630 176 82292 123 83715-7 129
80072 81 82295 123 83748 125
80073 81 82570 27 83800 60
80074 81 82653 60 83817 52
80075 81 82655 60 83834 60

200
Index

83900 . . . . . . . . . . . . . . . . . . . . . . . . . . 129 85727 71 086505 165


83900-9 129 85728 87 086506 165
84015 158 85729 87 086507 165
84048 119 85730 87 86535 161
84050 68 85731 71 91863-1 119
84110 121 85732 71 91864-1 119
84501 157 85733 71 91865-1 119
84616 71 85734 71 91866-1 119
84944; 84961 64 85735 71 91883-1 121
84960; 84962 65 85736 87 91884-1 121
84980 71 85737 87 91885-1 121
84990 71 85738 87 91886-1 121
85430 28 85739 87 91976-1 119
85431 28 85740 87 247333 185
85432 28 85741 71 249279 119
85433 28 85742 71 249279 121
85434 59 85743 87 249280 119
85435 59 85744 87 249280 121
85436 59 85745 87 249281 119
85438 19 85746 87 249281 121
85440 19 85747 87 249282 119
85441 19 85748 87 249282 121
85442 57 85749 87 249649 119
85444 58 85750 87 270982 71
85445 58 85751 87 270982 87
85460 68 85752 87 271605 71
85474 87 85753 87 271606 71
85475 87 85754 87 272180 87
85479 87 85770-1 143 272180 87
85492 71 85770-2 143 274899 87
85492 87 85770-3 143 276325 87
85497 142 85770-4 143 276764 73
85520 159 85770-5 143 276765 73
85525 160 85770-6 143 276903 87
85664 87 85771 143 276919 87
85665 87 85772 143 282288 69
85722 71 086500 164 283167 17
85723 71 086501 164 350241 191
85724 71 086502 164 350241 192
85725 71 086503 164 350242 191
85726 71 086504 165 350242 192

201
Index

350244. . . . . . . . . . . . . . . . . . . . . . . . . . 191 12381386 67 KFB1-4-S1 37


350244 192 12381700 67 KFB1-6-S1 37
350245 191 12381701 67 KFB1-M+924 39
350245 192 12381702 67 KFB1-M-W+924 39
350282 191 12382666 67 KFB1-W 37
350282 193 12389912 79 KFB1-W-4-S1 37
350283 191 12389916 79 KFB1-W-6-S1 37
350283 193 12389919 79 KFBS1 37
11390060 63 12389924 79 KFBS1-4-S1 37
11390070 63 12389925 79 KFBS1-6-S1 37
11395200 79 12389936 79 KFBS1-M+924 39
11395210 79 12389937 79 KFBS1-M-W+924 39
11395211 79 12389942 79 KFBS1-W 37
11395227 79 12389943 79 KFBS1-W-4-S1 37
11395254 79 12389944 79 KFBS1-W-6-S1 37
11500608 156 12389953 79 KFU2-40+912 41
11500610 79 12389954 79 KFU2-40+924 41
11500610 155 12501270 152 KFU6-20+912 41
12375000 83 DSC1–A040A–1A2A 184 KFU6-20+924 41
12375040 83 DSC2–A100E–2A2B 178 KFUS2-64+912 41
12375080 83 DSC3–A100K–3A2B 179 KFUS2-64+924 41
12375120 83 EXZT2A02+471 149 LRM2-E-01-100 167
12375160 83 EXZT2A02+472 149 LS2110 95
12375200 83 EXZT2A05+471 149 LS2120 95
12380210 153 EXZT2A05+472 149 LS2130 95
12380220 153 EXZT2A07+471 149 LS2140 95
12380600 154 EXZT2A07+472 149 LS2150 95
12380692 154 GS304P 188 LS2210 94
12380760 152 IG 502-2-E+912 150 LS2220 94
12380765 152 IG 502-2-E+924 150 LS2230 94
12381280 83 IGZ36-20+471 149 LS2240 94
12381285 83 IGZ36-20+472 149 LS2250 94
12381290 83 IGZ36-20-S6+471 149 MFE2-K3-2 47
12381292 83 IGZ36-20-S6+472 149 MFE2-K3F-2 47
12381294 83 IGZ38-30+471 149 MFE2-K6F 47
12381296 83 IGZ38-30+472 149 MFE2-K6F-S2 47
12381381 67 IGZ38-30-S1+471 149 MFE2-KW3F-S9+MPG 47
12381382 67 IGZ38-30-S1+472 149 MFE2-KW3F-S13+1FV 47
12381383 67 IGZ51-20-S3+471 149 MFE2-KW6F-S1 47
12381384 67 IGZ51-20-S3+472 149 MFE2-KW6F-S20+MPG 47
12381385 67 KFB1 37 MFE2-KW6F-S37+1FV 47

202
Index

MFE2-KW6F-S41+1FW 47 PF-289 21
MFE5-B3-2 47 PFE-15-0 5 16
MFE5-B7 47 PFE-15-1 0 16
MFE5-BW3-2 47 PFE-15-1 0W2 16
MFE5-BW3-2-S28 47 PFE-15-1 7 16
MFE5-BW3-S41+MPG 47 PFE-15-1 7W2 16
MFE5-BW3-S-S34+1FV 47 PFEP-15-0 5 23
MFE5-BW7 47 PFEP-15-1 0 23
MFE5-BW7-S22+1FV 47 PFEP-15-1 0W2 23
MFE5-BW7-S97+1FW 47 PFEP-15-1 7 23
MFE5-BW7-S107+MPG 47 PFEP-15-1 7W2 23
MFE5-BW7-S222+MPG 47 PFW-289 21
MFE5-BW16 47 POE-15-0 5 15
MFE5-BW16-S96+MPG 47 POE-15-1 0 15
MFE5-BW16-S145+1FV 47 POE-15-1 0W 15
MFE5-BW16-S222+MPG 47 POE-15-1 7 15
MFE5-BW30 47 POE-15-1 7W 15
MFE5-BW30-S30 47 POEP-15-0 5 22
MFE5-BW30-S35+MPG 47 POEP-15-1 0 22
MFE5-BW30-S222+MPG 47 POEP-15-1 0W 22
MFE5-K3-2 47 POEP-15-1 7 22
MFE5-K6 47 POEP-15-1 7W 22
MFE5-KW3-2 47 PW-289 21
MFE5-KW3-2-S4 47 V71-010 105
MFE5-KW3-S24+MPG 47 V71-020 105
MFE5-KW3-S35+1FW 47 V71-040 105
MFE5-KW3-S37+1FV 47 V71-060 105
MFE5-KW6 47 V71-100 105
MFE5-KW6-S1 47 V71-150 105
MFE5-KW6-S33+MPG 47 V72-005 105
MFE5-KW6-S42+1FV 47 VKU005-K 115
MFE5-KW6-S102+1FW 47 VKU010-K 115
P-289 21 VKU020-K 115
PEF-90 29 VKU030-K 115
PEF-99W 29 VKU040-K 115
PEF-99W-S1 29 VKU060-K 115
PEF-99W-S2 29 VKU100-K 115
PEF-99W-S3 29
PEU-99 29
PEU-99-S2 29
PEU-99-S3 29

203
Important information on product usage
! SKF and Lincoln lubrication systems or their components are not
approved for use with gases, liquefied gases, pressurized gases in
solution and fluids with a vapor pressure exceeding normal atmospheric
pressure (1 013 mbar) by more than 0,5 bar at their maximum
permissible temperature.

skf com | skf com/lubrication | lincolnindustrial com


® SKF and LINCOLN are registered trademarks of the SKF Group.
© SKF Group 2020
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
PUB LS/P1 17046 EN · July 2020
Certain image(s) used under license from Shutterstock.com

You might also like