F18 Installation Guide V1.2.2
F18 Installation Guide V1.2.2
Lock Connection
F18 Installation Guide (1) Share power with the lock:
Version: V1.2.2 Date: Jan, 2012 + +
+12V +12V
- GND
- GND
10
lay cables according to the mounting
paper.
NO2
11
COM2 COM2
12
13
Fixing Hole Fixing Hole
(1) Post the mounting template on the (2) Remove the screw on the (3) Take away the back plate. (2) Does not share power with the lock:
wall. Drill the holes according to bottom of device.
the marks on the template (holes
for screws and wiring). +
+12V + +12V
DC12V - GND
- GND Does not shares power with the lock:
BELL- DC12V
A. ULOCK=12V I-ILOCK≤1A;
+ BELL-
BELL+ -
BELL+
+ SEN - FR 107
SEN
B. ULOCK≠12V;
+
GND GND C. The distance between the lock and
NO LOCK
DC Power
- BUT
-
BUT
the device is more than 10 meters.
NO1 NO1
- COM1 COM1
+
NC1 + NC1
FR 107 NO2
+ - NO2
COM2 COM2
NC LOCK DC Power
(4) Fix the plastic pad and the back (5) Tighten the screw on the bottom,
plate on the wall according to the fix the device to the back plate. (1) The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open at
mounting paper. power on) is connected with ‘NO’ and COM
‘ terminals,
’ and the NC LOCK(normally close at power
on) is connected with ‘NC’and ‘COM’ terminals.
(2) When the Electrical Lock is connected to the Access control System, you need to parallel one FR107
2. Structure and Function diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not
reverse the polarities.
Access Control System Function
RS485 TCP/IP (1) If a registered user verified, the device will export the
⑦ signal to unlock the door.
RS232/RS485 Converter ⑤ (2) Door sensorwill detect the on-off state If the door is
4. Other Parts Connection: 5. Power Connection:
④
EXIT
BUTTON
unexpected opened or improperly closed, the alarm signal BELL-
① Input DC 12V, 500mA (50mA standby). Positive
Lock Sensor ② ⑥ Exit Button (digital value) will be triggered.
Door Bell
% BELL+
SEN is connected with ‘+12V’, negative is connected
(3) If the device is removed illegally, it will output an EXIT
GND with ’GND’ (do not reverse the polarities).
BUTTON
BUT
alarm signal.
% Exit Button NO1
(4) External card reader is supported. COM1
Bell Reader
Alarm Power NC1
NO2 Door Sensor + +12V
(5) External exit button is supported, it is convenient to
open the door inside. - COM2 - GND
Alarm (7) Supports RS485,TCP/IP modes to connect with PC. One Alarm Voltage output ≤ DC 12V
PC can manage multiple devices. ①:‘I’: device output current, ‘ULOCK’: lock voltage,‘ILOCK’: lock current
Po wer- Bla ck
/ Wiegand 34 output, so you can connect it supports to connect with an independent card reader. (2) Communications of PC:
with most of the access control devices by They are installed each side of the door, to control the Acces s Con tr ol D evice Re ad er
now. lock and access together. Please use specified RS485 wire, RS485 active
DATA0
WD0 +12V
converter and bus-type wiring. 485+
+12V 485-
DATA1
WD1 GND Terminals: 485+ 485-
GND GND
GND DATA1
IWD1 Terminals PC Serial Ports
RXD DATA0 RS485 Bus
IWD0 485+ RS485+ 485+ 485- 485+ 485-
TXD RLED
RLED 485- RS485-
GND GLED
Access Control Panel GLED RS485
485+ BEEP
BEEP
(3) TCP/IP Mode: Converter
485-
(1) Please keep the distance between the device and access control or card reader less than 90 meters About the terminals definition, please refers Terminals Wire Name Color
to the right table. RJ45-1 TX+ White-orange
(Please use Wiegand signal extender in long distance or interference environment). RJ45-2 TX- Orange
(2) To keep the stability of Wiegand signal, connect the device and the access control or card reader in Two ways for TCP/IP connection: RJ45-3 RX+ White-green
same ‘GND’ in any case. RJ45-6 RX- Green
(A) Crossover cable: The device and PC
connected directly. (B) Straight cable: The device and PC connected
to LAN/WAN through switch/Lan switch.
8.Other Functions PC Switch