F18 Installation Guide V1.2.2

The document is an installation guide for the F18 access control system, detailing power sharing options with locks and wiring instructions. It includes steps for mounting the device, connecting various components, and configuring communication modes such as RS232, RS485, and TCP/IP. Additionally, it provides cautions and recommendations for proper installation and operation to avoid damage.

Uploaded by

Quicas Mesa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views2 pages

F18 Installation Guide V1.2.2

The document is an installation guide for the F18 access control system, detailing power sharing options with locks and wiring instructions. It includes steps for mounting the device, connecting various components, and configuring communication modes such as RS232, RS485, and TCP/IP. Additionally, it provides cautions and recommendations for proper installation and operation to avoid damage.

Uploaded by

Quicas Mesa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

3.

Lock Connection
F18 Installation Guide (1) Share power with the lock:
Version: V1.2.2 Date: Jan, 2012 + +
+12V +12V
- GND
- GND

1. Equipment Installation BELL-


Device shares power with the lock:
BELL-
DC12V BELL+ DC12V BELL+
SEN
ULOCK=12V, I-ILOCK>1A… ①
SEN
GND
Wiring Hole
NC LOCK BUT - + GND
BUT
And the distance between the lock
FR 107
Fixing Hole Fixing Hole
-
+
NO1 - NO1 and the device is equal or less
F18 Mounting Paper
FR 107 COM1 + COM1
(only for your reference)
than 10 meters.
Instruction for the Mounting Paper
Before the device is fastened, please
stick the paper to the place where you
+ - NC1
NO LOCK NC1
NO2
want to install it, then make holes and

10
lay cables according to the mounting
paper.
NO2
11
COM2 COM2
12

13
Fixing Hole Fixing Hole

(1) Post the mounting template on the (2) Remove the screw on the (3) Take away the back plate. (2) Does not share power with the lock:
wall. Drill the holes according to bottom of device.
the marks on the template (holes
for screws and wiring). +
+12V + +12V

DC12V - GND
- GND Does not shares power with the lock:
BELL- DC12V
A. ULOCK=12V I-ILOCK≤1A;
+ BELL-
BELL+ -
BELL+
+ SEN - FR 107
SEN
B. ULOCK≠12V;
+
GND GND C. The distance between the lock and
NO LOCK
DC Power
- BUT
-
BUT
the device is more than 10 meters.
NO1 NO1
- COM1 COM1
+
NC1 + NC1
FR 107 NO2
+ - NO2
COM2 COM2
NC LOCK DC Power

(4) Fix the plastic pad and the back (5) Tighten the screw on the bottom,
plate on the wall according to the fix the device to the back plate. (1) The system supports NO LOCK and NC LOCK. For example the NO LOCK (normally open at
mounting paper. power on) is connected with ‘NO’ and COM
‘ terminals,
’ and the NC LOCK(normally close at power
on) is connected with ‘NC’and ‘COM’ terminals.
(2) When the Electrical Lock is connected to the Access control System, you need to parallel one FR107
2. Structure and Function diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not
reverse the polarities.
Access Control System Function
RS485 TCP/IP (1) If a registered user verified, the device will export the
⑦ signal to unlock the door.
RS232/RS485 Converter ⑤ (2) Door sensorwill detect the on-off state If the door is
4. Other Parts Connection: 5. Power Connection:

EXIT
BUTTON
unexpected opened or improperly closed, the alarm signal BELL-
① Input DC 12V, 500mA (50mA standby). Positive
Lock Sensor ② ⑥ Exit Button (digital value) will be triggered.
Door Bell
% BELL+
SEN is connected with ‘+12V’, negative is connected
(3) If the device is removed illegally, it will output an EXIT
GND with ’GND’ (do not reverse the polarities).
BUTTON
BUT
alarm signal.
% Exit Button NO1
(4) External card reader is supported. COM1
Bell Reader
Alarm Power NC1
NO2 Door Sensor + +12V
(5) External exit button is supported, it is convenient to
open the door inside. - COM2 - GND

③ (6) External door bell is supported. + Alarm DC12V

Alarm (7) Supports RS485,TCP/IP modes to connect with PC. One Alarm Voltage output ≤ DC 12V
PC can manage multiple devices. ①:‘I’: device output current, ‘ULOCK’: lock voltage,‘ILOCK’: lock current

* Reserves the final rights of modification and interpretation by our company.


! Warning: No operating with power on.
6. Wiegand Output 7. Wiegand Input 485+ Yello w
Pur ple
485-
Diagram of RS485Reader Function (Right)
The device supports standard Wiegand 26 The device has the function of Wiegand signal input. It Po we r + Red

Po wer- Bla ck
/ Wiegand 34 output, so you can connect it supports to connect with an independent card reader. (2) Communications of PC:
with most of the access control devices by They are installed each side of the door, to control the Acces s Con tr ol D evice Re ad er
now. lock and access together. Please use specified RS485 wire, RS485 active
DATA0
WD0 +12V
converter and bus-type wiring. 485+
+12V 485-
DATA1
WD1 GND Terminals: 485+ 485-
GND GND
GND DATA1
IWD1 Terminals PC Serial Ports
RXD DATA0 RS485 Bus
IWD0 485+ RS485+ 485+ 485- 485+ 485-
TXD RLED
RLED 485- RS485-
GND GLED
Access Control Panel GLED RS485
485+ BEEP
BEEP
(3) TCP/IP Mode: Converter
485-

(1) Please keep the distance between the device and access control or card reader less than 90 meters About the terminals definition, please refers Terminals Wire Name Color
to the right table. RJ45-1 TX+ White-orange
(Please use Wiegand signal extender in long distance or interference environment). RJ45-2 TX- Orange
(2) To keep the stability of Wiegand signal, connect the device and the access control or card reader in Two ways for TCP/IP connection: RJ45-3 RX+ White-green
same ‘GND’ in any case. RJ45-6 RX- Green
(A) Crossover cable: The device and PC
connected directly. (B) Straight cable: The device and PC connected
to LAN/WAN through switch/Lan switch.
8.Other Functions PC Switch

(1) Manual Reset:


If the device does not work properly because of misoperation or

Side View Back View
other abnormality, you can use ‘Reset’ function to restart it.
IP Address:192.168.1.201 IP Address:192.168.1.124
Operation: Remove the black rubber cap, then stick the Reset
Subnet Mask:255.255.255.0 Subnet Mask:255.255.255.0
button hole with a sharp tool (the tip diameter is less than 2mm).

(2) Tamper Switch 10. Cautions:


When the device is being dismantled, it will send an alarm (1)Power cableis connected after all the o ther wiring. If the device isoperated abnormally, please shut
signal through the terminal. do wn the power firstly, then make somenecessary checking. Kindly remain that anyhot-
plugging maydamag e device, and it is not included in the warranty.
Reset Button Tamper Switch (2) We recommend that use the DC 12V/ 3A power supply. For details, please contact our technical
personnel or sales.
9. Communication (3) Please read the terminals description carefully and wiring by rule strictly. Any damage
caused by improper operations will be out of the range of our guarantee.
There are three modes that the PC software could communicate and exchange information with the device:
(4) Keep thee xpose
dpar to fwire is less than 5mm to avoid unexpected connection,and resulti
achinery
nm damage.
RS232, RS485 and TCP/IP, and the last two modes support remote control.
(5) Please connect the"GND"before all the other wiring especially under the serious electrostatic environment,
1. RS232 Mode: Terminals PC Serial Ports to prevent the overlarge instantaneous electrostatic to damage device.
GND Pin5-Gnd
Terminals definition, please refers to the right table: (6)If the distance between power supply and device is a little long, please do not use the Internet
RXD Pin3-Txd
2. RS485 Mode: TXD Pin2-Rxd cable or other types of cable instead. When choosing the power supply cable, you should
(1) RS485Reader: consider that the transmission distance may cause voltage attenuation.
Equipment supports 485reader function, can be through the 485communication connected to
(7) Please use specified RS485 wire, RS485 active converter, and adopt bus-type wiring. If the communication
FR1200 reader; meanwhile, it can act as Master-slaver which device for master, FR1200 reader
wire is longer than 100 meters, it is needed to parallel a terminal resistance on the last device of RS485 bus,
for slaver, achieve 485 Anti-passback functions. If select “485reader function” , so device can
and the value is about 120 ohm.
not connect with PC through 485 communications.
* Reserves the final rights of modification and interpretation by our company.
! Warning: No operating with power on.