Parker Valves Pdn1000us Brass-Poppet Sliding-Seal
Parker Valves Pdn1000us Brass-Poppet Sliding-Seal
Parker Valves Pdn1000us Brass-Poppet Sliding-Seal
Parker Pneumatic
arker Hannifin Corporation will extend its warranty on all pneumatic components to sixty (60) months providing they are correctly installed and protected by Parker pneumatic filters which are properly maintained. Components covered by this warranty include all cylinders, valves and pneumatic automation components manufactured by Parker in any of our global facilities. This warranty covers our components anywhere in the world you may ship your equipment. Parker's obligation under this warranty is limited to the replacement or repair of any failed components. The buyer understands that the seller will not be liable for any other costs or damages. The buyers of quality Parker components and filters benefit by having ONE source for all pneumatic needs - Parker.
Catalog PDN1000US
Parker Pneumatic
A
Index
DISTRIBUTION NETWORK
At Parker, we have the largest global distribution network in motion and control, with over 7,500 distributors serving more than 422,000 customers.
To find the distributor nearest you, please visit our DISTRIBUTOR LOCATOR at http://www.parker.com/pneu/distributor
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this document entitled Offer of Sale.
Copyright 2011 Parker Hannifin Corporation. All Rights Reserved
Offer of Sale
A1
Catalog PDN1000US
Parker Pneumatic
These are 4-Way, 3-Position, rotary disc, direct-operated air valves. Two different types of control are offered. The forged bronze disc and the cast iron surface upon which the disc works are ground and lapped to provide a leak-proof seal. Air pressure from the inlet port is confined beneath the disc, making the seal tighter as the pressure increases, yet friction between the lapped surfaces is so low that only 15 pounds of force is required to move the lever at 100 PSI line pressure. The need for packing to seal around the stem is eliminated. Valve can be furnished for gasketing to a manifold on customers machine or with an adaptor for tapped bottom porting. Valves are detented. Operating handles may be installed in any of four positions.
Operating information
Operating pressure: 0 to 150 PSI (0 to 1035 kPa) Temperature range: 18F to 200F (-8C to 93C) Lubrication: Filtered and lubricated air recommended for maximum valve life and minimum maintenance.
Description 4-way, 3-position, detent, closed center 4-way, 3-position, detent, closed center 4-way, 3-position, detent, closed center 4-way, 3-position, detent, exhaust center 4-way, 3-position, detent, exhaust center 4-way, 3-position, detent, exhaust center
CYL
CYL
EXH
IN
45
45
C M J K
H G A
B F P (4 holes) E D
D
L 5.06 (129) 5.06 (129) 6.75 (171) M .34 (9) .34 (9) .34 (9) N .28 (7) .28 (7) .34 (9) P 1/4 NPT 3/8 NPT 1/2 NPT
PL-VL Dimensions
A PL-25 VL-25 PL-37 VL-37 PL-50 VL-50 4.75 (121) 4.75 (121) 5.62 (143) B 3.81 (97) 3.81 (97) 4.44 (113) C 6.81 (173) 6.81 (173) 8.94 (227) D 1.69 (43) 1.69 (43) 2.12 (54) E .56 (14) .56 (14) .66 (17) F 2.75 (70) .56 (14) 3.25 (83) G 4.12 (105) 4.12 (105) 5.00 (127)
D189
Catalog PDN1000US
Parker Pneumatic
Features
Compact and simple design Rotary disc, direct operated valves Side porting Detent action smooth lever actuation General pneumatic applications
Operating information
Operating pressure: 0 to 150 PSI (0 to 10 bar) Temperature range: 32F to 166F (0C to 60C) Lubrication: Filtered and lubricated air recommended for maximum valve life and minimum maintenance.
Materials
Cover Body Seals Zinc Aluminum Polyurethane
HV Valve Series
Symbol
CW C2 N C1 CCW
45
45
45
45
2.56 (65) 1.93 2.44 (49) (62) .22 (5.5) Mtg. Hole 4 Places
IN
3.81 (97)
C2
IN
HVN4200-8
Most popular. For technical information see CD
D
Manual / Mechanical Valve Products
4.84 (123)
HVN4400-10, 15
D190
2
C
Catalog PDN1000US
Parker Pneumatic
Sliding seal valves provide 3 or 4-Way directional control in a compact body size. Comfortable hand lever is easy to operate and maintains set position. Disc type valve has minimum number of moving parts. Valves should be used with filtered and lubricated air.
! CAUTION: Install guards on all hand operated valves. Accidental operation can cause personal injury.
Materials
Internal components Body Seals Brass, stainless steel Die cast zinc Buna N
Operating information
Operating pressure: Max. 200 PSIG air only Min. 26" Hg vacuum Temperature range: -40F to 212F (-40C to 100C) If it is possible that the ambient temperature may fall below freezing, the medium must be moisture free to prevent internal damage or unpredictable behavior.
Note: 3-Way exhaust passage is through an untapped hole in bottom side of valve.
45 3/4 Dia.
7/64 2R 7/64
B
1-7/16
A Inlet
A Inlet
3/4
3/4
1 Dia.
11/64
1
9/32
9/32
NOTE: With lever in position shown, inlet port 3 is connected to port 4 and exhaust is through port 1.
D191
033200390 Knob
1 Dia.
Catalog PDN1000US
Parker Pneumatic
For Use With PXBB Valve Bodies and ZBE Electrical Switch Bodies Push Buttons
Plastic head** Color Black Green Red Yellow Blue Black Green Red Yellow Black Green Red Black Green Red Detent Flush 2 position Spring return Booted Spring return Extended Spring return Flush Function Type ZB5AA2 ZB5AA3 ZB5AA4 ZB5AL2 ZB5AL3 ZB5AL4 Metal head* ZB4BA2 ZB4BA3 ZB4BA4 ZB4BA5 ZB4BA6 ZB4BL2 ZB4BL3 ZB4BL4 ZB4BL5 ZB4BP2 ZB4BP3 ZB4BP4 ZB4BH02 ZB4BH03 ZB4BH04 Metal mounting ring ZB4BZ009
Part number
Spring return
For Push Buttons and Visual Indicators Mounting Ring for Valve Bodies, Switch Bodies and Operating Heads
Description Part number
* ZB4*** model numbers are metal head operators ** ZB5*** model numbers are plastic head operators
ZB5AZ009
Note: To release push button from mounting ring, pull lever on top of mounting ring up and remove push button operator. To assemble push button operator to mounting ring, align arrows and snap into place.
Selector Switches
Standard black handle Description Maintained Spring return from right to left Maintained Spring return to center from left and right Maintained right spring return from left to center 3 positions 2 positions Function Part number* ZB4BD2 ZB4BD4 ZB4BD3 ZB4BD5 ZB4BD7 ZB4BD8
3 positions
D
Accessories Valve Products
Maintained left spring 3 positions return from right to center Long Black Handle Maintained Spring return from right to left Maintained Spring return to center from left and right 3 positions 2 positions
D193
Catalog PDN1000US
Parker Pneumatic
For Use With 2B4*** Metal Operating Heads 3/2 Valve Bodies with Mounting Ring
PXBB3111B
PXBB4131B
PXBB3911
PXBB4932
PXBB4931
Part number PXBB3111B PXBB3121B PXBB4131B Connections 5/32" instant straight 5/32" instant swivel 5/32" instant straight 5/32" instant swivel 5/32" instant straight 5/32" instant swivel Function 3/2 3/2 3/2
* NNP: Normally non-passing. Note: Mount up to 3 valves on mounting ring for push buttons. Mount up to 2 valves on mounting ring for selector switches, valves cannot be mounted in center position.
For Push Buttons and Visual Indicators Legend Plates for PXBB Devices (22mm)
Description Without text for customer engraving Black / red background (white letters) Yellow / white background (black letters) With text for push buttons Start Stop Forward Reverse Up Down Right Left On Off Open Close ZBY2303 ZBY2304 ZBY2305 ZBY2306 ZBY2307 ZBY2308 ZBY2309 ZBY2310 ZBY2311 ZBY2312 ZBY2313 ZBY2314 ZBY2321 ZBY2323 ZBY2326 ZBY2327 ZBY2328 ZBY2330 ZBY2334 Off With text for 3 position selectors Hand Off Auto ZBY2387 On ZBY2367 ZBY2101 ZBY4101 Part number
D
Accessories Valve Products
Inch Reset Power On Slow Fast Emergency stop Run With text for 2 position selectors
Note: Plastic mounting ring ZB5AZ009 to be used with ZB5 plastic operating heads. Metal mounting ring ZB4BZ009 to be used with ZB4 metal operating heads. Electrical specification: 240V, 10Amp
D194
Catalog PDN1000US
Parker Pneumatic
With 5/32" Instant Connections 22mm Visual Indicators
Black Plastic Bezel Color Green Red Yellow Blue White Part number ON indicator PXVF131 PXVF141 PXVF151 PXVF161 PXVF111 Part number OFF indicator PXVF1213 PXVF1214 PXVF1215 PXVF1216 PXVF1211
Metal
PXPEM510
Notes: The Pneumatic Indicators are black in one position and colored in the other. The colored position corresponds either to the presence of a pressure (ON Indicator) or the absence of pressure (OFF Indicator).
With 5/32" Instant Connections, 1/16" I.D. Internal Orifice Rotary Selector Switches, 22mm (7/8")
Without mechanical stop, 4-positions, 4-outputs 3/2 Operating head Black handle with 2.5" X 2.5" (64 X 64 mm) legend plate, red or black background
* NNP: Normally non-passing.
Two-Hand Controls
Connections 5/32 Instant Part number PXPC111
Black handle with 2.5" X 2.5" (64 X 64 mm) NNP legend plate, red or black background
* NNP: Normally non-passing.
Mounting Accessories
Color Description Plastic head (ZB5) mounting nut tightening tool Part number ZB5AZ905 ZBZ1602
With 5/32" Instant Connections, 1/16" I.D. Internal Orifice Joystick Operators, 22mm (7/8")
2-Position Unit 4-Position Unit
D
Accessories Valve Products
Part number
5/32" Instant
PXBGA8211 Chrome plated lever with protective bellows 1.6" X 2.5" PXBGA8411 (40 X 64 mm) legend plate red or black background PXBGA8221 PXBGA8421
* NNP: Normally non-passing. Note: These joystick operators come assembled with switch type PXBB1911, but will accept all switch bodies shown later in this Section.
D195
Catalog PDN1000US
Parker Pneumatic
To achieve the sensing or feedback function, pneumatic sensors can be: Limit switches in a variety of sizes and configurations Pressure switches with many adjustable ranges Components designed specifically for pneumatic technology using pressure variation, air bleed or blocking for detection. A wide variety of pneumatic sensors are available to suit any application requirement.
Materials
Body Poppets Seals Zinc Alloy Polyurethane Nitrile (Buna N)
Operating information
Operating pressure: Operating temperature: Operating Storage 40 to 115 PSIG (3 to 8 bar) 32F to 122F (0C to 50C) -22F to 140F (-30C to 60C)
D
Accessories Valve Products
* NNP: Normally non-passing. Most popular.
NNP
8.8 (250)
7/64" (2.5mm)
5/32" instant
PXCM601A102
PXCM601A103
D196
Catalog PDN1000US
Parker Pneumatic
Standard Duty Limit Switches K Series Plunger Operated Limit Switches
1/8" I.D. Internal Orifice, 5/32" Instant Connections, Pipeable Exhaust Port
Actuator Type of switching* NNP Steel plunger NP NNP Steel roller plunger NP NNP Plastic roller plunger NP PXCK22121 7.4 (210) 1/8" (3mm) 5/32" instant PXCK22102 PXCK21121 PXCK22101 PXCK21102 Flow SCFM (NI/min) Nominal bore Connection Part number PXCK21101
PXCK21106
PXCK22106
Adjustable delrin roller lever multi-function head NNP actuates: - from right and left - from right NP - from left
D
Accessories Valve Products
D197
Catalog PDN1000US
Parker Pneumatic
Standard Duty Limit Switches K Series Operating Heads
For Use With PXCK Switch Bodies
Actuator Rotary operated Plunger operated Roller plunger Whisker Rod plunger Delrin roller lever on plunger Steel roller lever on plunger Plunger operated ZCKD02 ZCKD06 ZCKD10 ZCKD21 ZCKD23 Die cast zinc ZCKG00 Description Part number
Description
Part number ZCKY51 ZCKY52 ZCKY81 ZCKY91 ZCKY11 ZCKY13 ZCKY41 ZCKY43
Rod levers
Delrin roller lever Steel roller lever Adjust. delrin roller lever Roller levers
Type of switching*
PXCJ117
Offset delrin roller Metal spring rod Delrin roller Offset delrin roller Single track, delrin roller
Description
D
Accessories Valve Products
Spring return
Cats whisker From left & right Counterclockwise from right Clockwise from left From left or right Spring return
Maintained positions
D198
Catalog PDN1000US
Parker Pneumatic
The blocking valve is a single acting spring return 2/2 valve in a fitting format. The device requires a pneumatic pilot signal to open, which allows free flow of air, gas or liquid to pass. As long as a pilot signal is present, the device will remain open. When the pilot signal is removed, the internal spring will close the blocking valve, bubble tight. The blocking valve is oil serviceable and rated to 150 PSI. These devices have two primary design uses: (1) to prevent unwanted gravity induced motion in cylinders during shut down procedures or during periods of lost supply pressure and (2) freezing the cylinder position by using a blocking valve at each end of the cylinder. Application needs such as tool or work piece protection, horizontal indexing or inspection stops are often satisfied by these devices.
Materials
Body Zinc alloy
Operating information
Operating pressure: Operating temperature: Operating Storage 0 to 150 PSIG (0 to 10.3 bar) 5F to 140F (-15C to 60C) -40F to 160F (-40C to 70C)
NPT Connection for tube 6mm 6mm 8mm 8mm 10mm 12mm Connection for pilot Cylinder port thread (male) 1/8" 1/4" 5/32" Tube 3/8" 1/2" Connection for tube 1/4" 1/4" 3/8" 1/2"
Symbol
1/2"
NPT Connection from valve (female) 1/4" 1/4" 3/8" 1/2" Connection for pilot Cylinder port thread (male) 1/8" 5/32" * Tube 1/4" 3/8" 1/2" Connection from valve (female) 1/8" 1/4" 3/8" 1/2"
Symbol
D
Accessories Valve Products
D199
Catalog PDN1000US
Parker Pneumatic
The plug-in threshold sensors provide feedback information on pneumatic cylinder status in either pneumatic or electrical outputs. Mounted into the cylinder port, these devices monitor the back pressure of the cylinder's exhaust. When the cylinder's piston stops, the back pressure rapidly drops and the threshold sensor provides the desired output. Ideal for variable stroke applications such as robotics where other sensor type devices such as limit switches are impractical, these devices provide a signal whenever the cylinder stops motion. The threshold sensor consists of two complementary sub assemblies (1) the banjo fitting and (2) the plug-in sensor element. In all cases, the sensor is easily plugged into the banjo fitting and locked in place with a spring clip. The banjo fitting is designed to accept (piggy backed) other functional fittings such as flow controls or blocking valves. Simply select the sensor based on the type feedback signal that best fits the application.
Materials
Body Mounting screw Thermoplastic Brass
Operating information
Operating pressure: Operating temperature: Operating Storage 0 to 150 PSIG (0 to 10.3 bar) 5F to 140F (-15C to 60C) -40F to 160F (-40C to 70C)
Plug-in Sensors
Output Pneumatic Connection 5/32" push-in 3-wire cable (6 ft) Part number PWSP111 PWSM1012
D
Accessories Valve Products
Electrical
D200
Catalog PDN1000US
Parker Pneumatic
Miniature Limit Switches
PXCM111
.80 (20.2) 2 x .13 (3.2) dia.
PXCZ12
PXCZ11
96 (24.5)
.41 (10.5)
1.38 (35)
.31 (8)
.12 (3)
1.38 (35)
.30 (10)
.16 (4)
.94 (24)
.75 (19)
PXCM121, PXCM131
PXCM521
.69 (17.5)
.55 (14)
Funct. stroke .08 (2) Max. stroke .13 (3.2)
.26 (7)
1.06 (27)
.91 (23)
.55 (14)
.26 (7)
1.61 (41)
2x .17 (4.2)
2.05 (52)
.59 (15)
.35 (9)
.59 (15)
PXCM601A103
G .47 (12)
1.18 (30)
.79 (20) 1.18 (30)
1.18 (30)
1.46 (37)
.63 (16)
1.46 (37)
.63 (16)
PXCM601A110
G .47 (12)
D
Accessories Valve Products
.32 (8)
.77 (19.5)
.79 (20) 1.18 (30)
1.46 (37)
.63 (16)
D201
Catalog PDN1000US
Parker Pneumatic
K Series
PXCK21101, PXCK22101 PXCK21102, PXCK22102
.16 (4) .59 (15)
PXCK21121, PXCK22121
1.91 (48.5) .79 (20) .59 (15)
PXCK21106, PXCK22106
.63 (16) .08 (2)
.39 (10)
.63 (16)
.51 (13)
.31 (8)
2.3 (59)
3.7 (94)
2.81 (72)
4.21 (107)
3.03 (77)
7.91 (201)
.79 (20)
.79 (20)
.79 (20)
.79 (20)
PXCK2110031, PXCK2210031
.24 (6) 2.13 (54) 1.5 (38)
PXCK2110041, PXCK2210041
.24 (6) 2.05 (52) 1.73 (44)
.87 (22)
.75 (19)
1.61 (41)
2 Holes .2 (5.2)
3.33 (84.5)
2 Holes .2 (5.2)
.79 (20) 2.36 (60) .79 (20)
2.28 (58)
1.10 (28)
2.50 (63.5)
a b
a b
e r
D
Accessories Valve Products
c d e
ZCKY91
2.05 (52)
.31 (8)
.12 (3)
D202
Catalog PDN1000US
Parker Pneumatic
J Series Switch Body With Plunger Heads
With ZC2JE61
With ZC2JE62
.77 (19.5) .08 (2)
With ZC2JE70
.77 (19.5)
.47 (12)
.77 (19.5)
.47 (12)
.16 (4)
1.85 (47)
With ZC2JY31
1.54 to 2.80 (39 to 71)
With ZC2JY51
2.13 to 2.60 (54 to 66)
.87 (22)
1.8 to 3.4 (46 to 86) 4.25 (108) 2.7 to 4.3 (69 to 109) 4.33 to 5.9 (110 to 150)
.12 (3)
2.56 (65)
2.56 (65)
2.56 (65)
ZC2JY91
2.13 to 2.36 (54 to 60) .31 (8) .87 (22)
ZC2JY41
.31 (8)
.20 (5)
2.56 (65)
2.56 (65)
2.56 (65)
inch
= 1.5 (38)
mm 12 19 29.5 29 to 30 30 7 11 13 24
Parker Hannifin Corporation Pneumatic Division Richland, Michigan www.parker.com/pneumatics
D
Accessories Valve Products
a b c d
.47 .75 1.16 1.14 to 1.18 1.18 .28 .43 .51 .94
f e 1.9 (48)
e
b a g h k
f g h k
D203
Catalog PDN1000US
Parker Pneumatic
Blocking Valves
PWBA14/34
A
A 0.86" (22)
K
B 0.82" (21) 0.82" (21) 1.10" (28) 1.30" (33) 0.82" (21) 0.82" (21) 1.10" (28) 1.30" (33) 0.87" (22) 0.87" (22) 1.18" (30) 1.18" (30)
C 0.94" (24) 0.94" (24) 0.94" (24) 1.30" (33) 0.94" (24) 0.94" (24) 0.94" (24) 1.30" (33) 0.83" (21) 0.83" (21) 1.06" (27) 1.06" (27)
K 0.53" (13.5) 0.53" (13.5) 0.55" (14) 0.94" (24) 0.53" (13.5) 0.53" (13.5) 0.55" (14) 0.94" (24) 0.67" (17) 0.67" (17) 0.91" (23) 0.91" (23)
H 2.32" (59) 2.09" (53) 2.09" (53) 2.59" (66) 2.32" (59) 2.09" (53) 2.09" (53) 2.59" (66) 2.20" (56) 2.20" (56) 2.64" (67) 2.64" (67)
L 1.54" (39) 1.54" (39) 1.98" (50) 2.59" (66) 1.71" (43.5) 1.71" (43.5) 2.18" (55) 2.47" (63) 1.73" (44) 1.73" (44) 1.42" (36) 1.42" (36)
Flow* 14.8 19.4 45.9 81.2 14.8 19.4 45.9 81.2 14.8 19.4 45.9 81.2
Part number PWBA1468/3468 PWBA1469/3469 PWBA1489 PWBA1483 PWBA1493/3493 PWBA1412/3412 PWBA1898/3888 PWBA1899/3899 PWBA1833/3833 PWBA1822/3822 PWBA38887 PWBA38997 PWBA38337 PWBA38227
0.86" (22) 1.06""(27) 1.22" (31) 0.86" (22) 0.86" (22) 1.06" (27) 1.22" (31) 0.75" (19) 0.75" (19) 1.06" (27) 1.06" (27)
PWBA18/38
A
PWBA38
1/8" NPT C A C
Threshold Sensors
Banjo Socket
H
A .98 (25)
K
B .43 (11) .63 (16) .83 (21) 1.10 (28) 1.30 (33)
C 5/16" Hex 3/16" Allen 5/16" Allen 3/8" Allen 1/2" Allen
H .79 (20) .71 (18) .71 (18) .79 (20) .93 (24)
K .40 (10) .40 (10) .40 (10) .47 (12) .55 (14)
L .67 (17) .79 (20) .87 (22) .98 (25) 1.02 (26)
B
B/2 L
D
Accessories Valve Products
PWSP111
.79 (20)
.87 (22)
PWSM1012
18 x 24
1.26 (32)
.79 (20)
D204
Catalog PDN1000US
Parker Pneumatics
Safety Guide For Selecting And Using Pneumatic Division Products And Related Accessories
! WARNING:
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEMBLIES OR RELATED ITEMS (PRODUCTS) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAMAGE. POSSIBLE CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS INCLUDE BUT ARE NOT LIMITED TO:
Unintended or mistimed cycling or motion of machine members or failure to cycle Work pieces or component parts being thrown off at high speeds. Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device. Explosion Suddenly moving or falling objects. Release of toxic or otherwise injurious liquids or gasses. Before selecting or using any of these Products, it is important that you read and follow the instructions below. 1. GENERAL INSTRUCTIONS 1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components. 1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or property. 1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see: ISO 4414:1998, Pneumatic Fluid Power General Rules Relating to Systems. See www.iso.org for ordering information. 1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected. 1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own analysis and testing, is solely responsible for: Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory. Assuring that all users performance, endurance, maintenance, safety, and warning requirements are met and that the application presents no health or safety hazards. Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the valves, FRLs or Vacuum products are used; and, Assuring compliance with all applicable government and industry standards. 1.6. Safety Devices: Safety devices should not be removed, or defeated. 1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured. 1.8. Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional information. See the Parker publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com, for telephone numbers of the appropriate technical service department. 2. PRODUCT SELECTION INSTRUCTIONS 2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system. System components need to be able to provide adequate flow and pressure for the desired application. 2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the instruction sheets supplied for maximum pressure ratings. 2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product and result in complete product failure. 2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to premature failure of a product. 2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the factory or product literature for materials of construction. 2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures: Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures outside of the rated range. Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols. Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as phosphate ester and di-ester lubricants.
G
Safety Guide, Offer of Sale
G5
Catalog PDN1000US
Parker Pneumatics
G
Safety Guide, Offer of Sale
2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins Tec-3, Tec-4, and Tec-5 2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage. Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders. Do not exceed the maximum primary pressure rating of any pressure regulator or any system component. Consult product labeling or product literature for pressure rating limitations. 3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS 3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any signs of nonconformance. 3.2. Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at www.parker.com. 3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient temperature can drop below freezing 4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS 4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10. 4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing the Parker web site at www.parker.com. 4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more information see: OSHA Standard 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy (Lockout / Tagout) 4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged components: Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an indication of worn or damaged components. Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation. Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior. Any observed improper system or component function: Immediately shut down the system and correct malfunction. Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations. Caution: Leak detection solutions should be rinsed off after use. 4.5. Routine Maintenance Issues: Remove excessive dirt, grime and clutter from work areas. Make sure all required guards and shields are in place. 4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate properly and safely. 4.7. Service or Replacement Intervals: It is the users responsibility to establish appropriate service intervals. Valves, FRLs and vacuum products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need to be established based on: Previous performance experiences. Government and / or industrial standards. When failures could result in unacceptable down time, equipment damage or personal injury risk. 4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal injury and property damage: Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout Tagout procedures (OSHA Standard 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy Lockout / Tagout). Disconnect electrical supply (when necessary) before installation, servicing, or conversion. Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service, or conversion. Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how pneumatic products are to be applied. After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into use. Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local representative for replacement labels. 4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions supplied with the valve FRL or vacuum component to insure proper function of the system.
G6
Catalog PDN1000US
Parker Pneumatics
The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors (Seller) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (Buyer) shall be governed by all of the following Terms and Conditions. Buyers order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred to as Products. 1. Terms and Conditions. Sellers willingness to offer Products, or accept an order for Products, to or from Buyer is expressly conditioned on Buyers assent to these Terms and Conditions and to the terms and conditions found on-line at www.parker.com/ saleterms/. Seller objects to any contrary or additional term or condition of Buyers order or any other document issued by Buyer. 2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages of this document are valid for 30 days. After 30 days, Seller may change prices to reflect any increase in its costs resulting from state, federal or local legislation, price increases from its suppliers, or any change in the rate, charge, or classification of any carrier. The prices stated on the reverse or preceding pages of this document do not include any sales, use, or other taxes unless so stated specifically. Unless otherwise specified by Seller, all prices are F.O.B. Seller's facility, and payment is due 30 days from the date of invoice. After 30 days, Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum allowable rate under applicable law. 3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and Seller shall not be responsible for any damages resulting from any delay. Regardless of the manner of shipment, title to any products and risk of loss or damage shall pass to Buyer upon tender to the carrier at Seller's facility (i.e., when its on the truck, its yours). Unless otherwise stated, Seller may exercise its judgment in choosing the carrier and means of delivery. No deferment of shipment at Buyers' request beyond the respective dates indicated will be made except on terms that will indemnify, defend and hold Seller harmless against all loss and additional expense. Buyer shall be responsible for any additional shipping charges incurred by Seller due to Buyers changes in shipping, product specifications or in accordance with Section 13, herein. 4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in material or workmanship for a period of twelve months from the date of delivery to Buyer or 2,000 hours of normal use, whichever occurs first. This warranty is made only to Buyer and does not extend to anyone to whom Products are sold after purchased from Seller. The prices charged for Seller's products are based upon the exclusive limited warranty stated above, and upon the following disclaimer: dISClAIMeR oF WARRANTy: THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days of delivery. No other claims against Seller will be allowed unless asserted in writing within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 days after the date within the warranty period on which the defect is or should have been discovered by Buyer. Any action based upon breach of this agreement or upon any other claim arising out of this sale (other than an action by Seller for any amount due to Seller from Buyer) must be commenced within thirteen months from the date of tender of delivery by Seller or, for a cause of action based upon an alleged breach of warranty, within thirteen months from the date within the warranty period on which the defect is or should have been discovered by Buyer. 6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER'S WRITTEN CONSENT, EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER'S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. 7. Contingencies. Seller shall not be liable for any default or delay in performance if caused by circumstances beyond the reasonable control of Seller. 8. User Responsibility. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and Product and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application and follow applicable industry standards and Product information. If Seller provides Product or system options, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the Products or systems. 9. Loss to Buyer's Property. Any designs, tools, patterns, materials, drawings, confidential information or equipment furnished by Buyer or any other items which become Buyer's property, may be considered obsolete and may be destroyed by Seller after two consecutive years have elapsed without Buyer placing an order for the items which are manufactured using such property. Seller shall not be responsible for any loss or damage to such property while it is in Seller's possession or control. 10. Special Tooling. A tooling charge may be imposed for any special tooling, including without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. Such special tooling shall be and remain Seller's property notwithstanding payment of any charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to Seller which is utilized in the manufacture of the Products, even if such apparatus has been specially converted or adapted for such manufacture and notwithstanding any charges paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise dispose of any special tooling or other property in its sole discretion at any time. 11. Buyer's Obligation; Rights of Seller. To secure payment of all sums due or otherwise, Seller shall retain a security interest in the goods delivered and this agreement shall be deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes Seller as its attorney to execute and file on Buyer's behalf all documents Seller deems necessary to perfect its security interest. Seller shall have a security interest in, and lien upon, any property of Buyer in Seller's possession as security for the payment of any amounts owed to Seller by Buyer. 12. Improper use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for personal injury, property damage, patent, trademark or copyright infringement or any other claim, brought by or incurred by Buyer, Buyers employees, or any other person, arising out of: (a) improper selection, improper application or other misuse of Products purchased by Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Sellers use of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product; or (d) Buyers failure to comply with these terms and conditions. Seller shall not indemnify Buyer under any circumstance except as otherwise provided. 13. Cancellations and Changes. Orders shall not be subject to cancellation or change by Buyer for any reason, except with Seller's written consent and upon terms that will indemnify, defend and hold Seller harmless against all direct, incidental and consequential loss or damage. Seller may change product features, specifications, designs and availability with notice to Buyer. 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this agreement without the prior written consent of Seller. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer and Seller and constitutes the final, complete and exclusive expression of the terms of the agreement. All prior or contemporaneous written or oral agreements or negotiations with respect to the subject matter are herein merged. 16. Waiver and Severability. Failure to enforce any provision of this agreement will not waive that provision nor will any such failure prejudice Sellers right to enforce that provision in the future. Invalidation of any provision of this agreement by legislation or other rule of law shall not invalidate any other provision herein. The remaining provisions of this agreement will remain in full force and effect. 17. Termination. This agreement may be terminated by Seller for any reason and at any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller may by written notice immediately terminate this agreement for the following: (a) Buyer commits a breach of any provision of this agreement (b) the appointment of a trustee, receiver or custodian for all or any part of Buyers property (b) the filing of a petition for relief in bankruptcy of the other Party on its own behalf, or by a third party (c) an assignment for the benefit of creditors, or (d) the dissolution or liquidation of the Buyer. 18. Governing Law. This agreement and the sale and delivery of all Products hereunder shall be deemed to have taken place in and shall be governed and construed in accordance with the laws of the State of Ohio, as applicable to contracts executed and wholly performed therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio with respect to any dispute, controversy or claim arising out of or relating to this agreement. Disputes between the parties shall not be settled by arbitration unless, after a dispute has arisen, both parties expressly agree in writing to arbitrate the dispute. 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets or similar rights except as provided in this Section. Seller will defend and indemnify Buyer against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress and trade secrets (Intellectual Property Rights). Seller will defend at its expense and will pay the cost of any settlement or damages awarded in an action brought against Buyer based on an allegation that a Product sold pursuant to this Agreement infringes the Intellectual Property Rights of a third party. Seller's obligation to defend and indemnify Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of such allegations of infringement, and Seller having sole control over the defense of any allegations or actions including all negotiations for settlement or compromise. If a Product is subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may, at its sole expense and option, procure for Buyer the right to continue using the Product, replace or modify the Product so as to make it noninfringing, or offer to accept return of the Product and return the purchase price less a reasonable allowance for depreciation. Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based on information provided by Buyer, or directed to Products delivered hereunder for which the designs are specified in whole or part by Buyer, or infringements resulting from the modification, combination or use in a system of any Product sold hereunder. The foregoing provisions of this Section shall constitute Seller's sole and exclusive liability and Buyer's sole and exclusive remedy for infringement of Intellectual Property Rights. 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise, sales, use, property, occupational or like taxes which may be imposed by any taxing authority upon the manufacture, sale or delivery of Products. 21. Equal Opportunity Clause. For the performance of government contracts and where dollar value of the Products exceed $10,000, the equal employment opportunity clauses in Executive Order 11246, VEVRAA, and 41 C.F.R. 60-1.4(a), 60-741.5(a), and 60-250.4, are hereby incorporated.
G
Safety Guide, Offer of Sale
G7